Fig 1.
Experimental setup and SSVEP responses.
(A) Participants carried all experimental equipment and walked freely in a 45 × 27 metre sports hall (the participant is marked with a yellow circle). Walking speed for the different walking conditions is shown on the right. (B) Illustration of the central flickering grating (visual angle: 6.1°) at four different levels of surround contrast (visual angle: 21.5°). An example contrast change (target) is shown in the second row. (C) Raw power spectrum of EEG responses in different walking conditions (left). Inset shows power responses around the SSVEP frequency of 15 Hz. Cyan lines mark the frequencies that showed power differences between walking conditions (p < 0.05, FDR-adjusted). Note that the power difference actually extends far beyond 35 Hz. Shading indicates ±1 standard error, n = 25 participants. Scalp topography of the average SSVEP response from all conditions is shown in the middle, and the source of the SSVEP response is estimated to be in the primary visual cortex in all conditions with dipole fitting (right). The original data are available from https://doi.org/10.6084/m9.figshare.9094742.v1. EEG, electroencephalogram; FDR, false discovery rate; SSVEP, steady-state visual evoked potential.
Fig 2.
Influence of surround contrast depends on movement state.
(A) SSVEP responses (left: referenced SSVEP power; middle: raw SSVEP power) and detection rates (right) significantly decreased with higher surround contrast levels during walking but not during standing still. Vertical lines indicate ±1 standard error, n = 25 (SSVEP); n = 30 (detection rate). Refer to S1 Table for break-down statistics. (B,C) Individual data from contrast level 0% and 100% for referenced SSVEP power and raw SSVEP power. Red lines indicate participants whose data patterns do not conform to suppression (detection rate at 100% contrast larger or equal to 0% contrast). (D) Same as B but showing the individual detection rate. The original data are available from https://doi.org/10.6084/m9.figshare.9094742.v1. SSVEP, steady-state visual evoked potential.
Fig 3.
Interaction between SSVEP power and alpha power and the proposed mechanism of interaction.
(A) In all three walking conditions, stronger SSVEP power was associated with stronger alpha power. No significant differences in other frequency bands were found. Shading indicates ±1 standard error. Grey bars indicate the alpha band (8–12 Hz), and asterisks indicate significant differences, n = 25 participants. (B) The diagram illustrates the suggested mechanistic influence of walking. Compared to standing still, walking leads to a decrease in inhibition indicated by alpha power (red area). This decreased inhibition gives a processing advantage to the peripheral visual field. In our specific stimulus, the peripheral visual field inhibits the central area (the strength depends on the background contrast). If the periphery is processed more strongly, the contrast of the background poses stronger influence on the central area. Consequently, SSVEP and behavioural detection rate (both exclusively probed and introduced in the central part of the visual field marked by the black circle) will decrease. The original data are available from https://doi.org/10.6084/m9.figshare.9094742.v1. SSVEP, steady-state visual evoked potential.
Fig 4.
Walking leads to a processing advantage of peripheral stimuli.
(A) Schematic illustration of the stimulus. Left, the size and position of all five targets (T1–T5) of contrast change are marked by circular white lines (not visible for the participant), corresponding to the ratio of real stimulus presentation. Stimulus size is given in pixel and visual angle. Right, an example of a T2 contrast change is shown. Note that the grating background was constantly at 100% contrast. (B) Detection threshold for all targets in both standing still and normal walking condition. (C) The relative detection threshold difference between normal walking and standing still for all targets. Each connected pair showed a significant difference (post hoc t test with FDR-adjusted p-values for multiple comparisons, p < 0.05). Vertical lines indicate ±1 standard error, n = 27 participants. The original data are available from https://doi.org/10.6084/m9.figshare.9094742.v1. FDR, false discovery rate.