Abstract
Traditional infectivity-based virion quantification methods, such as 50% tissue culture infectious dose (TCID50) and plaque assays, are typically performed in 6-, 12-, 24-, or 48-well cell culture plates and require manual work and analysis based on legacy protocols. Adaptation of these methods to high-throughput formats (96-, 384- or 1,536-well plates) is challenging due to both assay automation constraints and the lack of well surface area available for reliable analysis. Here, we present a scalable alternative to traditional methods that uses whole-well image thresholding to quantify infectious virions by measuring virus-induced cytopathic effect (CPE) via cell lysis and detachment. The CPE area assay is best positioned as a practical high-throughput preliminary screening tool, effectively quantifying samples within the assay range and flagging samples above or below the concentration thresholds. To improve analysis efficiency and reduce user bias in CPE area selection, we evaluated an nnU-Net model for automated image segmentation against images segmented by manually defined brightness thresholds. The model achieved strong correlation with manual thresholding (R2 = 1.00), showing minimal differences in the identified CPE area and thus demonstrating that nnU-Net accurately reproduces manual analysis. This approach provides two complementary pipelines: manual thresholding, which tolerates adjustments of hyperparameters, and fully automated segmentation via nnU-Net, which streamlines analysis and enhances throughput. This flexible CPE area assay enables accurate and automated quantification in high-throughput screening formats, thereby greatly accelerating a routine laboratory task while decreasing subjectivity and bias.
Author summary
Measuring the amount of virus in a biosample is a critical part of viral research and testing of new treatments. Traditional methods are slow, labor-intensive, and not easily scaled up to handle large numbers of samples. In this study, we developed a new approach that makes the process faster, more efficient, scalable, and less reliant on manual steps. We used microscopy imaging to capture how cells respond to virus infections and analyzed these images automatically to identify and measure areas where the virus had damaged cells. The analysis pipeline allows researchers to fine-tune settings or run the process using machine learning. This method is flexible and adaptable to a variety of viruses and experiments. By increasing the number of samples that can be tested at once while reducing the time and effort needed for analysis, our approach has the potential to accelerate research in virology, drug development, and public health.
Citation: Murphy MJ, Mazur S, Postnikova EN, Eaton BP, Kocher GA, Chu W, et al. (2026) High-throughput virus quantification using cytopathic effect area analysis. PLoS Comput Biol 22(9): e1013511. https://doi.org/10.1371/journal.pcbi.1013511
Editor: Farshad Moradi Kashkooli, University of Waterloo, CANADA
Received: September 8, 2025; Accepted: September 1, 2026; Published: September 16, 2026
This is an open access article, free of all copyright, and may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. The work is made available under the Creative Commons CC0 public domain dedication.
Data Availability: Code is available at: https://github.com/niaid/irf-area-viral-quant. Data/Images from this study are available at https://doi.org/10.7303/syn69680467.
Funding: This research was supported in part by the Intramural Research Program of the National Institutes of Health (NIH) under Contract No. HHSN272201800013C. The contributions of the NIH author(s) are considered Works of the United States Government. The findings and conclusions presented in this paper are those of the author(s) and do not necessarily reflect the views of the NIH or the U.S. Department of Health and Human Services C. S.M., B.E., G.A.K., and M.G.L. performed this work as employees of Laulima Government Solutions, LLC. M.J.M., E.N.P., W.C., and J.H.K. performed this work as employees of Tunnell Government Services (TGS), a subcontractor of Laulima Government Solutions, LLC. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. The authors have declared that no competing interests exist.
Competing interests: The authors have declared that no competing interests exist.
Introduction
Virion quantification methods can be broadly categorized into infectivity assays or component analysis. Infectivity assays strictly measure virions, i.e., virus particles capable of successfully infecting a given host cell, whereas component analysis measures virus proteins, DNA, RNA, or total virus particles [1]. Existing infectivity assays are poorly suited for scalable, high-throughput, and automated workflows, creating a gap between functional virus measurement and modern screening techniques. Among infectivity assays, plaque assays have been the gold standard for over 70 years [2–5]. Plaque assays rely on virus-induced cytopathic effect (CPE), which includes changes in cell morphology and physiology stemming from virus infection, to produce typically circular clearings of lysed or detached cells, i.e., plaques, within a cell monolayer [2 3 6]. Samples are serially diluted to achieve a concentration of virions that produce visibly distinguishable independent plaques, thus facilitating human-annotated counting. A viral titer is then calculated in plaque-forming units (PFU) per volume of sample. Dilutions that generate plaques too numerous to manually count or dilutions with overlapping plaques and unidentifiable epicenters are generally excluded. Requiring a sufficiently large cell monolayer to support the formation of multiple distinct plaques imposes a surface area constraint on the cell culture plate format. Consequently, plaque assays are generally performed in 6-, 12-, 24-, or 48-well plates, which are not conducive to high-throughput, automated platforms.
A widely used alternative for quantifying viral infectivity is an endpoint dilution method known as the 50% tissue culture infectious dose (TCID50) assay, which measures CPE in the form of cell lysis and detachment rather than development of discrete plaques [7]. Unlike plaque assays, the TCID50 assay is not constrained by surface area limitations, making it more adaptable to high-throughput formats. In practice, the TCID50 assay involves exposure of cultured cells to serially diluted pathogen samples, incubation of the cells until CPE becomes visible to the unaided eye, and analysis using statistical methods to calculate the dilution at which 50% of the wells exhibit cell lysis or detachment. However, TCID50 assays rely on binary classification of wells and require large numbers of replicates to achieve statistical reliability, ultimately limiting data resolution and scalability.
Traditional plaque and TCID50 assays require manual annotation of CPE in cell monolayers to calculate viral titers [2 6]. Dependence on visual scoring makes both assays labor-intensive, prone to bias, and difficult to scale up for high-throughput or automated platforms. Microscopy imaging offers an unbiased solution, replacing manual well inspection with image-based readouts that can be rapidly acquired with many replicates. These large imaging datasets provide a foundation for applying computational approaches. Importantly, microscopy imaging is compatible with high-throughput formats (e.g., 96-, 384-, and 1,536-well plates), enabling experimental output that traditional assays cannot accommodate.
Recent advances in artificial intelligence (AI) have further expanded the potential of microscopy-based assays by enabling automated analysis pipelines [8]. By utilizing convolutional neural networks (CNN) and vision transformers (ViTs), deep learning can reduce or eliminate the need for human annotation through automated plaque counting and CPE quantification [4 5 8–11]. However, existing AI-based approaches remain constrained by assay design rather than model capability. Automated plaque counting still requires sufficient surface area to resolve individual plaques, and automated TCID50 pipelines continue to rely on binary classification of wells as either CPE-positive or CPE-negative [8].
To overcome the limitations of existing assays and methods, we developed a high-throughput infectivity assay that follows established infection and staining protocols similar to those used in plaque assays, while replacing the discrete plaque-counting readout with a continuous measurement of CPE area, calibrated directly against known viral titers via a standard curve. This approach is conceptually related to TCID50, which also relies on CPE as an infectivity readout, but avoids reducing that readout to a binary classification. By integrating these existing concepts into a single high-throughput workflow, this approach overcomes the surface-area and scalability constraints of traditional infectivity assays, and we validate its performance using both manual thresholding and automated segmentation via nnU-Net.
Results
Workflow for virus quantification using cytopathic effect area
Permissive cells were seeded into 384-well plates and infected in quadruplicate with either samples of known virus concentration (controls) or experimental samples (Fig 1). Microcrystalline cellulose was used to limit viral diffusion. After a defined incubation period, cell layers were fixed and stained with crystal violet. To image the entire well, the Operetta CLS system acquired nine 10X images per well using both crystal violet fluorescence (excitation: 530–560 nm; emission: 655–760 nm) and brightfield.
(1) Suitable virus host cells are grown and exposed to virions. (2) Exposed cell monolayers are covered with microcrystalline cellulose, followed by addition of fixation and staining reagents. (3) High-throughput microscopy images of stained cell monolayers are acquired and processed. (4) Cell monolayers are thresholded using crystal violet and brightfield images. (5) Control wells with known viral titers are used to generate standard curves using four-parameter logistic (4PL) regression. The 4PL curve formula is used to predict viral titers in experimental samples. Created in BioRender. Murphy M. (2026) https://biorender.com/ztib3j6.
To quantify CPE, crystal violet images were segmented by applying a manually defined brightness threshold to distinguish cell monolayer from areas of lysis or detachment. Each pixel was classified as either “signal” (cell monolayer) or “background” (areas of lysis or detachment), depending on whether its intensity falls above or below the chosen threshold. The threshold value was manually selected by visual inspection of the images, often through trial and error, to ensure accurate segmentation. In parallel, brightfield images were processed to define the total well area. The CPE area was then calculated as the total area (from brightfield) minus the area of cell monolayer (from segmented crystal violet).
Controls were arranged as a 24-point dilution gradient across four rows, and standard curves were generated by plotting percent CPE against known viral titers. The equation derived from the standard curve was then applied to experimental samples to estimate viral titers.
Virus infection time influences sensitivity and dynamic range of the cytopathic effect area assay
While optimizing the workflow of the CPE area assay in 384-well plates, we observed that both infection duration and the inherent replication kinetics of the virus strongly influenced how CPE developed over time. To establish feasibility, we used Rift Valley fever virus (RVFV) vaccine strain under biosafety level 2 (BSL-2) conditions. RVFV was selected because it produces robust and reproducible CPE in Vero E6 cells and can be handled safely at BSL-2 using the attenuated vaccine strain, enabling systematic assay optimization prior to testing high or maximum containment pathogens. Vero E6 cells were seeded in 384-well plates and CPE development was assessed at 24, 48, and 72 h post-exposure (Fig 2).
(A, B, C) Overview images of 384-well Rift Valley fever infection plates at 24, 48, and 72 h. Red coloration indicates crystal-violet-stained cell monolayers. Controls are in rows A–D (all columns, with a decreasing viral titer from left to right columns). Experimental samples are in rows E–P, with replicates split between columns 1–12 and 13–24. (D, E, F) Percent CPE areas for controls at each time point with fitted four-parameter logistic (4PL) regression curves. (G, H, I) Predictions generated by applying the standard curve formula to percent CPE areas of experimental samples. Plate 1 and Plate 2 represent biological replicates. Predictions were defined as either “hit”, “borderline”, or “miss” based on the fold change (Δ) from the reference titer. A hit was defined as Δ < 3.16 (i.e., within a half-log difference), borderline as 3.16 < Δ < 10 (i.e., between a half-log and a full-log difference), and miss as Δ > 10 (i.e., greater than a full-log difference).
At each time point, the percentage of area with discernible CPE increased proportionally with viral titer (Fig 2A–2C). This time-dependent relationship illustrates how the assay captures both the extent and progression of infection, confirming its potential for quantitative viral load measurement (Fig 2D–2F).
The dynamic range of quantification shifted depending on infection duration. The lower limit of quantification (LLOQ) decreased from an average of 9.6 × 104 PFU/mL at 24 h to 2.7 × 103 PFU/mL at 48 h and further to 4.6 × 102 PFU/mL at 72 h. The upper limit of quantification remained relatively stable, averaging 6.4 × 106 PFU/mL at 24 and 48 h, with a slight decrease to 4.3 × 106 PFU/mL at 72 h.
Within the quantifiable range of the assay, predictive performance varied slightly across time points. Predictions were defined as either “hit”, “borderline”, or “miss” based on the fold change (Δ) from the reference titer. A hit was defined as Δ < 3.16 (i.e., within a half-log difference), borderline as 3.16 < Δ < 10 (i.e., between a half-log and a full-log difference), and miss as Δ > 10 (i.e., greater than a full-log difference).
This categorical system was chosen as a generally accepted variability of plaque assays is a half-log difference [12 13], and provides a practical framework for assessing assay performance without over-interpreting minor statistical variation. Additionally, precedent in infectivity assays suggests that positive controls should fall within a full-log of the reference titer for a test to be considered valid [14]. On this basis, we have set any sample outside of a full-log difference as invalid or “miss”. Values falling between a half-log and a full-log difference represent an intermediate zone of uncertainty, which we designated as “borderline.”
The 24-h time point yielded 86.1% (Wilson 95% confidence interval (WCI):71.3% - 93.9%) hits, 13.9% (WCI: 6.1% - 28.7%) borderline, and zero (WCI: 0.0% - 9.6%) missed predictions in 36 quantified samples (Fig 2G). The 48-h time point yielded 79.3% (WCI: 70.0% - 86.4%) hits, 19.6% (WCI: 12.7% - 28.8%) borderline, and 1.1% (WCI: 0.2% - 5.9%) missed predictions in 92 quantified samples (Fig 2H). The 72-h time point yielded 85.4% (WCI: 78.3% - 90.4%) hits, 13.8% (WCI: 8.9% - 20.8%) borderline, and 0.8% (WCI: 0.1% - 4.2%) missed predictions in 130 quantified samples (Fig 2I). Overall, these findings suggest that infection duration influences the quantifiable range of the assay, with the 48- and 72-h time points proving most suitable for future sample quantification in this study.
High-throughput cytopathic effect area assay provides a scalable alternative to traditional plaque assays
After establishing optimal infection conditions for RVFV in the CPE area assay, we directly compared assay performance at the 48-h time point with the traditional six-well plaque assay using 40 experimental samples (Fig 3). The standard curve for the CPE area assay was generated from a 24-point, 2-fold dilution series spanning from 7.63x10-1 to 6.40x106 PFU/mL. The 40 experimental samples ranged in concentration from 4.12x102 to 6.4x106 PFU/mL.
Comparison of the accuracy and dynamic range of the CPE area assay versus the traditional plaque assay using 40 experimental samples. Predictions were defined as either “hit”, “borderline”, or “miss” based on the fold change (Δ) from the reference titer. A hit was defined as Δ < 3.16 (i.e., within a half-log difference), borderline as 3.16 < Δ < 10 (i.e., between a half-log and a full-log difference), and miss as Δ > 10 (i.e., greater than a full-log difference). (A) CPE area assay predictions compared to reference titers for experimental samples in plate 1. (B) CPE area assay predictions compared to reference titers for experimental samples in plate 2 (biological replicate). (C) Traditional plaque assay predictions compared to reference titers for experimental samples.
All samples were quantifiable using the plaque assay, whereas 30% (WCI: 21.1% - 40.8%) of the lowest-titer samples were below the LLOQ in the CPE area assay. The plaque assay was highly accurate, with 97.5% (WCI: 87.1% - 99.6%) of quantified samples falling within a full-log and 95% (WCI: 83.5% - 98.6%) within a half-log of the reference titers. The 384-well CPE area assay was somewhat variable across plates but maintained good overall accuracy, quantifying 100% (WCI: 93.6% - 100.0%) of samples within a full-log and 85.7% (WCI: 76.4% - 93.8%) of samples within a half-log of the reference titers.
Bland–Altman analysis on log10-transformed titers demonstrated minimal systematic bias between the CPE area assay and the traditional 6-well plaque assay (S1 Fig). The mean difference was 0.019 log10 PFU/mL for plate 1 and 0.103 log10 PFU/mL for plate 2, indicating slightly higher titers measured by the 6-well assay. The lower limits of agreement (LoA) were similar between plates (−0.436 log10 for plate 1 and −0.497 log10 for plate 2). The upper LoA was 0.474 log10 for plate 1 (within half-log) and 0.702 log10 for plate 2 (exceeding half-log but remaining within a full-log). Within the established limits of quantification, the CPE area assay showed strong agreement with the traditional plaque assay, supporting its use as a high-throughput preliminary screening tool.
Cytopathic effect area assay with manual thresholding demonstrates greater accuracy and range than initial deep learning models
During optimization of the CPE area assay with RVFV, we observed distinct spatial patterns of CPE that varied with viral titers. We hypothesized that these spatial features could provide additional information about infection kinetics beyond the area of CPE alone and that deep learning models could incorporate this information to more accurately predict viral titer.
To test this, we trained a Siamese neural network (SNN) and fine-tuned a pretrained ViT model, with the manually thresholded CPE area assay serving as the baseline method for comparison (Fig 4A). The SNN was chosen because CNNs are well-established in medical imaging, and the Siamese framework offers the potential to reduce the number of controls required for a standard curve [15 16]. The SNN consisted of two parallel CNNs based on the AlexNet architecture [17], sharing weights and trained with a contrastive loss function to measure similarity between image feature representations of a sample image and an “anchor” image with a known viral titer (Fig 4B).
(A) CPE area assay method. Brightfield images are used to segment the full area of each well, generating a mask that defines the region of interest. Crystal violet images are then thresholded within this mask. Control wells with known viral titers are used to generate a standard curve via four-parameter logistic (4PL) regression, which is then used to predict viral titers in experimental samples. (B) SNN method. A crystal violet image from a control well with a known virus concentration is loaded as the anchor image. An experimental sample image is loaded in parallel, and both images are passed through identical convolutional neural networks (CNNs). The CNNs were trained on images from 3,840 RVFV-exposed independent cell monolayers. The network predicts a distance between the image embeddings, which is subtracted from the known concentration of the anchor to estimate the virus concentration of the experimental sample. (C) ViT method. Crystal violet images are passed through an ImageNet-pretrained ViT-B/16 that was fine-tuned on the same RVFV training dataset as the SNN. The output is a single value associated with each image. Values from control wells are used to generate a standard curve via 4PL regression, which is then used to predict virus concentrations in experimental samples.
We also compared the CPE area assay against a ViT model, as recent image classification benchmarks have demonstrated that ViTs can outperform CNNs in image classification tasks, especially with large pretraining datasets [18]. To overcome the limited size of our dataset, we fine-tuned an ImageNet-pretrained ViT-B/16 using the same training data as the SNN. This approach enabled us to leverage the ViT’s ability to capture long-range dependencies and high-level spatial features without requiring extensive infection image data (Fig 4C) [18].
For model training, 3,840 wells were exposed to RVFV using a broad range of viral titers at 48 h post-exposure. Full monolayer images were collected of each well and used collectively to train the SNN and fine-tune the ViT models. Models were trained once on the full training dataset rather than being retrained on individual infections or plates, enabling a single model to learn generalized morphological features associated with RVFV infection across viral concentrations.
Model performance was evaluated on independent 384-well plates fixed at 48 and 72 h post-exposure. Control wells were arranged in rows A–D as a 24-point, 2-fold dilution series spanning from 7.63x10-1 to 6.4 x 106 PFU/mL. Experimental samples were placed in rows E–P, with replicates distributed across columns 1–12 and 13–24, ranging in concentration from 4.12x102 to 6.4x106 PFU/mL.
The dynamic ranges of the CPE area assay and the ViT model were broadly similar (Fig 5). At 48 h after virus exposure, the LLOQ was 5.15 × 103 PFU/mL for the CPE area assay and 7.81 × 102 PFU/mL for the ViT. By 72 h, the LLOQ extended to 5.45 × 101 PFU/mL for the CPE area assay and 1.95 × 102 PFU/mL for the ViT. In contrast, the SNN performed poorly at both time points (Fig 5C) despite performing strongly on the original test dataset following training (S2 Fig).
Comparison of the accuracy and dynamic range of the cytopathic effect (CPE) area assay using manual thresholds versus deep learning methods using 72 experimental samples. Predictions were defined as either “hit”, “borderline”, or “miss”, based on the fold change (Δ) from the reference titer. A hit was defined as Δ < 3.16 (i.e., within a half-log difference), borderline as 3.16 < Δ < 10 (i.e., between a half-log and a full-log difference), and miss as Δ > 10 (i.e., greater than a full-log difference). (A) CPE area assay by manual threshold, (B) vision transformer (ViT) model, and (C) Siamese neural network (SNN) model predictions at 48 and 72 h after virus exposure. (D) Accuracy of each method, accounting for predictions both above and below the established limits of quantification.
At 48 h after virus exposure, the CPE area assay identified 36 predictions as hits, five as borderline, and zero as misses (Fig 5A). The ViT model identified 32 predictions as hits, 24 as borderline, and seven as misses (Fig 5B). When samples accurately identified as below the limit of detection were also classified as hits, the CPE area assay yielded 67 predictions as hits, five as borderline, and zero as misses. This equates to 100% (WCI: 94.9% - 100.0%) accuracy within 1 log and 93% (WCI: 84.8% - 97.0%) accuracy within a half-log. Under the same criteria, the ViT model yielded 38 predictions as hits, 26 as borderline, and eight as misses, corresponding to 89% (WCI: 80% - 94%) accuracy within 1 log and 53% (WCI: 41% - 64%) accuracy within a half-log (Fig 5D).
At 72 h after virus exposure, the CPE area assay again performed strongly, yielding 65 predictions as hits, seven as borderline, and zero as misses. This corresponds to 100% (WCI: 95% - 100%) accuracy within a half-log and 90% (WCI: 81% - 95%) accuracy within a full-log. The highest accuracy was observed in mid-range and lower concentration samples, with reduced precision at higher concentrations. The ViT model produced similar results, with 63 predictions as hits, nine as borderline, and zero as misses. This corresponds to 100% (WCI: 95% - 100%) accuracy within a half-log and 88% (WCI: 78% - 93%) accuracy within a full-log. Like the CPE method, the ViT model’s highest accuracy was in the mid-to-low concentration range, with diminishing precision at higher concentrations. The decline of both methods at high concentrations may be attributed to saturation, suggesting that diluting high-titer samples could improve prediction accuracy in this range.
Within the scope of the present study, the CPE area assay provided greater accuracy and dynamic range than the evaluated deep learning approaches. This comparison reflects an initial proof-of-concept implementation using a limited training dataset, downsampled single-channel crystal violet images, and a pretrained ViT architecture. Performance of deep learning models may improve with expanded training data and architectures specifically optimized for CPE quantification.
nnU-Net automated segmentation is a replacement for manual thresholding in CPE area identification
While most of the CPE area assay with manual thresholding is automated, it does require manual selection of brightfield and crystal violet intensity thresholds, which then determine the areas of plaque and cell monolayer. To improve consistency, remove bias, and decrease labor, we trained a nnU-Net framework on thresholded images of varying doses of EEEV, NiV, RVFV, or SARS-CoV-2 to automatically segment the whole-well area from brightfield images, and the cell monolayer from crystal violet images without manual thresholding (Fig 6). nnU-Net is a self-configuring deep learning semantic segmentation framework and has demonstrated robust performance in various biomedical image segmentation tasks without the need for manual tuning of hyperparameters [19].
Pixel differences between manual thresholding and nnU-Net segmentation identification of monolayer. (A) An example image using segmentation from a manually determined threshold value and automated segmentation from nnU-Net. (B) Percent cytopathic effect (CPE) area calculated from manually thresholded images compared to percent CPE area calculated by automated segmentation from nnU-Net on an independent test plate of eastern equine encephalitis virus.
When applied to a test plate not used during training or validation, the model produced segmentation masks that closely matched the thresholded images, with only minor pixel-level differences (Fig 6A) and a mean Dice score of .988 ± 0.015 on a hold-out test plate. Quantification of the CPE area showed excellent concordance between the two methods, with an R2 of 1.00 (Fig 6B), indicating that the nnU-Net model can replicate manual thresholding with high accuracy. This comparison was designed to establish agreement with manual thresholding, rather than to validate segmentation accuracy against an independent biological ground truth. Separately, it is important to note that the same viruses were used in both training and testing. While the test plate and images were independent, they are closely related to the training data, and performance may be lower on images from viruses the model was not trained on.
To evaluate the utility of the CPE area assay and demonstrate its application in maximum (biosafety level 4 [BSL-4]) containment laboratory settings, the assay was evaluated for use with eastern equine encephalitis virus (EEEV), Nipah virus (NiV), and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Although EEEV and SARS-CoV-2 are not classified as BSL-4 pathogens, all experiments were performed under uniform maximum-containment procedures to ensure consistent conditions across viruses. For each virus, results from manual image thresholding were compared to automated segmentation outputs generated by the nnU-Net model. This comparison provided further validation of the model’s ability to generalize across distinct CPE morphologies and varying assay conditions (Fig 7).
Comparison of the accuracy and dynamic range of cytopathic effect (CPE) area assays using manually thresholded images and nnU-Net automated segmentation. Predictions were defined as either “hit”, “borderline”, or “miss” based on the fold change (Δ) from the reference titer. A hit was defined as Δ < 3.16 (i.e., within a half-log difference), borderline as 3.16 < Δ < 10 (i.e., between a half-log and a full-log difference), and miss as Δ > 10 (i.e., greater than a full-log difference). (A) Rift Valley fever virus (RVFV) predictions using manually thresholded images compared to nnU-Net automated segmentation. (B) Nipah virus (NiV) predictions using manually thresholded images compared to nnU-Net automated segmentation. (C) Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) predictions using manually thresholded images compared to nnU-Net automated segmentation. (D) Eastern equine encephalitis virus (EEEV) predictions using manually thresholded images compared to nnU-Net automated segmentation.
These two methods gave a medium-sized assay range for EEEV (8.34 × 102–5.48 × 106 PFU/mL for manual thresholding and 6.97 × 102–5.43 × 106 PFU/mL for nnU-Net segmentation), with smaller ranges for NiV (1.38 × 103–7.72 × 105 PFU/mL for manual thresholding and 5.25 × 103–2.72 × 106 PFU/mL for nnU-Net segmentation) and RVFV (5.63 × 103–3.39 × 106 PFU/mL for manual thresholding and 5.25 × 103–2.72 × 106 PFU/mL for nnU-Net segmentation). The range for SARS-CoV-2 was exceptional (8.71 × 101–4.04 × 108 PFU/mL for manual thresholding and 8.20 × 101–4.83 × 108 PFU/mL for nnU-Net segmentation). These methods both yielded very accurate results, predicting greater than 99% of samples within 1 log and approximately 77% within a half-log for all viruses. Mean absolute error was similar for both methods across all viruses (Table 1).
Discussion
Initial comparisons between the CPE area assay and a traditional six-well plaque assay demonstrated its efficiency and scalability. While the six-well plaque assays required up to 124 plates to process 40 samples, the CPE area assay achieved the same with a single partial 384-well plate. In an ideal workflow, each 384-well plate can accommodate up to 72 experimental samples in quadruplicate, which is equivalent to approximately 216 six-well plates (assuming three plates per sample and excluding controls), highlighting a major improvement in throughput capacity. This increased capacity makes the CPE area assay particularly well-suited for high-throughput screening applications and large-scale studies, offering a substantial improvement in throughput without any considerable loss in data quality.
Importantly, percent CPE area is an infection phenotype rather than a measure of discrete infectious events, as measured by plaque assays in PFU. Although the CPE area assay has an overlay to restrict viral diffusion, the measured area remains a cumulative effect from viral entry, replication kinetics, and cell-to-cell spread, all of which affect the CPE phenotype. Consequently, predictive performance relies on the assumption that the replication efficiency, cytotoxic potential, and host cell susceptibility in the control standard curve are representative of those in the experimental samples. Optimization of infection conditions was therefore essential to ensure accurate representation of controls and maximizing assay resolution. For each virus tested, multiple time points and a range of virus concentrations were evaluated to determine conditions that produced sufficient CPE development and enabled a robust dynamic range for quantification.
Despite optimized conditions, the traditional plaque assay still had a broader quantifiable range, as shown in Fig 3. The traditional plaque assay was able to quantify all samples, regardless of virus concentration, whereas the CPE area assay was unable to quantify anything under approximately 1 × 104 PFU/mL. Extending the RVFV infection time to 72 h, as illustrated in Fig 2, could have improved the LLOQ. However, this adjustment introduces a tradeoff between broader dynamic range and decreased prediction accuracy at high concentrations. With its higher throughput but smaller dynamic range relative to the plaque assay, the CPE area assay is optimally positioned as a high-throughput screening tool that reliably quantifies samples within range while identifying those outside threshold concentrations.
The CPE area assay preserves spatial features of virus-induced cytopathology that can be leveraged by deep-learning approaches. The extent and morphology of CPE are shaped by underlying infection dynamics, including rates of cell-to-cell spread, heterogeneity in host cell susceptibility, and the kinetics of viral replication within a monolayer. By preserving spatial information as opposed to condensing infection outcomes into discrete plaque counts, direct image-based analysis enables deep-learning models, including the SNN and ViT, to learn complex morphological features associated with virus-host interactions. These models could provide a quantitative means to integrate spatial infection phenotypes across large datasets, offering insight into population-level infection dynamics.
To translate spatial infection phenotypes into quantitative predictions, we evaluated deep learning based approaches, including CNNs (via SNN) and ViTs. A SNN was evaluated and demonstrated strong performance on the initial test set, which originated from the same plates as the training data, but plateaued at higher concentrations in independent experimental plates. This pattern likely reflects the model’s difficulty generalizing infection patterns across different plates, particularly at high viral titers, as well as sensitivity to intraplate variability, since anchors were defined independently for each plate. This approach offered the theoretical advantage of reducing the number of required control wells to 12, potentially increasing assay throughput. However, this strategy fell short in terms of overall accuracy and needs to be further refined before implemented. Future improvements could involve replacing the current anchor-selection method, which is based on the most generalized mean absolute error, with a method that selects anchors showing the smallest predicted distance or greatest similarity to the experimental samples.
A ViT was fine-tuned on the same datasets as the SNN to evaluate how different deep learning architectures perform in CPE virus quantification. Unlike the SNN, the ViT model predicted continuous values directly from single images without reliance on anchor images. The ViT’s outputs were used to generate four-parameter logistic (4PL) regression models across standard curve values, analogous to the CPE area assay. The ViT predictions closely mirrored biological trends observed in the CPE area assay. This parallel trend suggests that the ViT is either closely aligned with the CPE area signal or learning image features directly associated with it. Precision was highest in the mid-range of the assay, consistent with the saturation effect at high concentrations noted above for the CPE area assay (Fig 5). Notably, the ViT used 224 × 224-pixel images due to constraints of the pretrained model architecture, whereas the CPE area assay used 405 × 405-pixel images. This reduction in image resolution could partially explain the slight reduction in prediction accuracy for this model compared to the CPE area assay.
One minor limitation in the percent CPE area assay was that it required manual review of the plates and thresholded images, which introduces subjectivity into the thresholding process. In many cases, thresholds needed to be changed for individual plates for what was considered the “masked” area on the brightfield image and for “positive” on the crystal violet image. To streamline the process of reviewing new plates, we trained an nnU-Net model to segment the images for CPE, cell monolayer, and background using both the crystal violet and brightfield images. This model showed exceptional accuracy in segmenting the image, matching the thresholded images almost perfectly. More importantly, this method was able to quantify samples with at least the same accuracy as the thresholding method, while requiring less effort from the technician running the assay. These methods both showed high accuracy in quantifying virus concentrations of EEEV, NiV, RVFV, and SARS-CoV-2.
Both approaches also performed similarly with respect to plate-to-plate reproducibility, with the standard deviation of MAE across plates remaining ≤0.10 log10 PFU/mL for all viruses. Broader biological reproducibility, including variability arising from different operators, virus stock preparations, or laboratories, was not systematically assessed in this study and represents a limitation that would benefit from further testing.
Despite these advantages, we do not consider nnU-Net a universal substitute for manual thresholding. The nnU-Net model presented here was trained on a defined set of viruses and assay conditions, and its performance on viruses or experimental conditions outside this training distribution cannot be assumed without additional validation. Manual thresholding therefore remains a practical option for new or untested viruses, and more broadly for laboratories without access to the computational infrastructure (e.g., GPUs or high-performance computing resources) required to train or deploy deep learning segmentation models. We present manual thresholding and nnU-Net not as redundant methods, but as complementary tools suited to different stages of assay development and different laboratory settings.
Materials and methods
Cell and virus maintenance
Grivet (Chlorocebus aethiops (Linnaeus, 1758)) Vero (ATCC, #CCL-81) and Vero E6 (BEI Resources, #NR-596) cells were used for virus propagation and maintained in Dulbecco’s Modified Eagle Medium with L-glutamine (DMEM; Gibco, #11995–040), supplemented with 10% heat-inactivated fetal bovine serum (FBS; Sigma Aldrich, #F4135), at 37°C with 5% carbon dioxide (CO2). For virus exposure experiments, cells were cultured in DMEM containing 2% heat-inactivated FBS under the same incubation conditions.
All viruses were propagated at the Integrated Research Facility at Fort Detrick in appropriate biosafety containment. The Rift Valley fever virus (RVFV) MP12 isolate was obtained from Dr. Robert Tesh (University of Texas Medical Branch) and propagated in Vero cells and incubated for 72 h under biosafety level 2 (BSL-2) conditions. Eastern equine encephalitis virus (EEEV) FL-93–939 isolate (BEI Resources, #NR-41567), Nipah virus (NiV) Malaysia (United States Army Medical Research Institute of Infectious Diseases), and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) WA.01 isolate (U.S. Centers for Disease Control and Prevention) were all propagated in Vero E6 cells under BSL-4 conditions. Nipah virus was incubated for 72 h, whereas EEEV and SARS-CoV-2 were incubated for 48 h.
Master stocks for each virus were generated and quantified using six-well plaque assays in Vero E6 cells with a 2.5% microcrystalline cellulose (FMC BioPolymer, RC-591) overlay. After incubation (48 or 72 h, depending on virus), plates were fixed with 10% neutral buffered formalin (NBF; Epredia, #5725) containing 0.2% crystal violet (Ricca Chemical, #3233-16) for plaque visualization.
Plaque assay (six-well plates)
Vero E6 cells were plated in six-well plates at a density of 1 × 106 cells per well to reach 90–100% confluence the following day. Log dilutions were performed on samples in 2-mL deep-well blocks with DMEM containing 10% heat-inactivated FBS. Samples were added, in triplicate of 100 µL per well, to individual wells and incubated at 37°C and 5% CO2 for 1 h, with rocking every 15 min. Then, 2 mL of 2.5% microcrystalline cellulose overlay (diluted [1:1] in 2X Modified Eagle Medium [MEM; Gibco, #11935–046] containing 10% heat-inactivated FBS, 2X Antibiotic-Antimycotic [Gibco, #15240–062], and 2X GlutaMAX [Life Technologies, #35050061]) were mixed thoroughly and added to each well. The cells were incubated at 37°C and 5% CO2 for 48 h. After incubation, the overlay was removed, and the cells were fixed with 0.2% crystal violet in 10% NBF at room temperature for 30 min. Plates were gently washed with water and the plaques manually counted.
Cytopathic effect (CPE) area assay
Vero E6 cells were seeded in 384-well plates at a density of 1 × 104 cells per well in 30 µL of DMEM containing 10% heat-inactivated FBS and incubated overnight at 37°C with 5% CO2. The following day, 30 µL of sample or virions were added to each well and incubated for 1 h at 37°C with 5% CO2. After incubation, 60 µL of 2.5% microcrystalline cellulose overlay (diluted [1:1] in 2X MEM containing 10% heat-inactivated FBS, 2X Antibiotic-Antimycotic, and 2X GlutaMAX) was added to each well and mixed thoroughly. The cells were incubated at 37°C and 5% CO2 for the designated infection period, after which the overlay and media were carefully discarded. Then, cells were fixed using 60 µL of 10% NBF for 1 h at room temperature. Next, NBF was removed and cells were stained with 60 µL of 0.2% crystal violet for 30 min at room temperature. The stain was gently washed off with water, and plates were dried at room temperature overnight prior to imaging on the Operetta CLS high-content imaging system (PerkinElmer/Revvity).
Cytopathic effect area assay analysis
The Operetta system captured nine images at 10X magnification per well to ensure full coverage of the cell monolayer. Crystal violet images were captured with excitation wavelength of 530–560 nm and emission wavelength of 655–760 nm. A brightfield image was captured for each well and used to generate a mask that defined the quantification area. These images were exported as TIF files, stitched together to generate a composite image of the entire well, and downsized to 405 × 405-pixel images to optimize long-term storage. During thresholding of the crystal violet image, only the pixels within the brightfield mask were analyzed, helping to eliminate artifacts and background noise from outside the well.
Threshold parameters were determined through consensus by at least two operators using representative high- and low-titer images from the standard curve prior to analysis of experimental samples. Once established, a single fixed threshold value was applied uniformly to all images within each plate to eliminate operator-dependent variability. Visual inspection was performed to confirm segmentation of monolayer from background, rather than to adjust thresholds on a per-image basis. Formal inter-operator agreement metrics were not calculated, as threshold determination was performed collaboratively and fixed prior to batch processing.
Percent area values from control images were used to construct a standard curve using a four-parameter logistic (4PL) regression function, which was applied to experimental percent area values to calculate final predicted virus concentrations.
Calculations and statistics
Dixon Q-test for outliers.
All samples for the CPE area quantification and CPE area reduction assays were run in quadruplicate and passed through a Dixon’s Q-Test at 95% confidence level to remove outliers prior to further analysis [20]. Dixon’s Q-test was selected because it is specifically designed for small sample sizes (n < 10) and is well suited for detecting a single potential outlier within quadruplicate replicate groups. For each set of four technical replicates, Dixon’s Q-test was applied at a significance level of α = 0.05 to evaluate whether a single extreme value should be excluded prior to downstream analysis.
Agreement analysis.
Agreement of CPE calculated viral titers and traditional plaque assay was evaluated using Bland-Altman analysis on log10 transformed titers with limits of agreement defined as the mean difference ± 1.96 x standard deviation of the differences [21]. Only samples for which both methods produced quantifiable values were included in the analysis.
Confidence intervals.
Sample-level accuracy proportions (samples classified as “Hit”, “Borderline”, or “Miss”) were summarized with 95% confidence intervals calculated using the Wilson score method for binomial proportions in the statsmodels python package [22].
Siamese neural network training and evaluation
Model setup.
The Siamese neural network (SNN) model [15 16] was implemented using the PyTorch library. It comprised two identical convolutional neural networks (CNNs) that were adapted from the standard AlexNet architecture to match the images in the current study. The input number of channels was set to one (for grayscale images) and the final fully connected layer was configured to output a 4,096-dimensional vector. The SNN model used the CNNs to process two 405 × 405-pixel images simultaneously. Two feature vectors generated by the identical networks are subtracted and the result is passed through a single linear layer to predict the difference in labels (regression value).
Training.
Ten 384-well plates were exposed to RVFV and fixed at 48 h post-exposure to generate the images for training, validation, and initial test sets. The Operetta imaging system can introduce slight angular deviations across the plate, causing some wells to appear offset; for example, the distance from the left edge of the image to the edge of the well in column 1 differs from that in column 12. To avoid the algorithm associating positional effects with virus concentration, an alternating high-low dilution pattern was adopted. This pattern was applied to five plates and then inverted for the remaining five plates to further reduce positional bias.
The dataset of 3,840 images was stratified and split into a 90:10 ratio, with 90% allocated to training and validation and the remaining 10% reserved for the initial test set. The 90% training/validation set was further split 90:10, resulting in 81% of the total images for training and 9% for validation. The model was trained for 50 epochs using a mean squared error (MSE) loss function to minimize the predicted distance between anchor and experimental images. Anchor images (reference images based on control wells) were selected at random during training and validation.
Evaluation.
To evaluate the performance of the SNN, a separate test dataset was used in conjunction with a set of pre-selected anchor images. Anchors were selected from a standard curve positioned on the same test plate as the evaluation samples. This standard curve consisted of reference images with known virus concentrations.
Each image in the standard curve was individually treated as a candidate anchor. For a given candidate, the model was used to compute the predicted differences between the candidate anchor and all other images in the standard curve. These predictions were compared to the ground truth differences, and the mean absolute error (MAE) was calculated for each candidate anchor’s prediction set.
This process was repeated for every image in the standard curve, yielding a set of MAE values corresponding to each candidate anchor. The prediction results were then averaged to quantify the overall predictive consistency and effectiveness of each image when used as an anchor. The final anchor set used for test evaluation consisted of those images on the test plate with the lowest average MAE, representing optimal reference points for the model’s comparative assessments.
Vision transformer
Model setup.
A ViT model (ViT-B_16) pretrained on ImageNet (1K_V1) was loaded using the torchvision package. To adapt it for regression tasks, the final classification layer was replaced with a linear layer that outputs a single continuous value. All input images were resampled to 224 × 224 pixels to match the model’s input size requirements.
Fine-tuning.
The images used for training the SNN were employed to fine-tune the ViT model. The dataset was split into training and validation subsets using an 80/20 split. The split was stratified by the target value (virus concentration) to ensure proportional representation. Hyperparameters were defined for training the model including the number of epochs (10), the image size (224 × 224 pixels), number of patches (14), learning rate (3 × 10-4), batch size (256), and MSE loss function.
Evaluation
The model was evaluated on a separate test dataset that was not used during training. For each input image, the model generated a single output representing the natural logarithm of virus concentration (in PFU/well). Predicted outputs from control wells were used to construct a standard curve using a 4PL regression. This curve was then applied to the model’s predictions for experimental wells to convert them into final estimated virus concentrations.
nnU-Net segmentation
An nnU-Net segmentation model was trained using grayscale TIF images from both crystal violet and brightfield channels. Images were merged and resampled as described above, with crystal violet assigned to channel 0 and brightfield to channel 1. Default normalization methods provided by nnU-Net were applied to each channel.
Ground truth masks were generated by manually applying intensity thresholds to both the crystal violet and brightfield images. Images were labeled 0 for non-relevant areas, 1 for the CPE area, and 2 for cell monolayer. Thresholds were selected independently for each plate. Areas falling below the brightfield threshold were labeled with 0. Regions above the brightfield threshold were labeled with 1 if below the crystal violet threshold or 2 if above it.
The training set comprised 10,748 images of cells infected with varying doses of EEEV, NiV, RVFV, or SARS-CoV-2. A five-fold cross-validation was performed, and the fold with the highest pseudo-Dice score as reported by nnUNet was selected for downstream analysis. A separate 384-well plate containing EEEV-infected cells at various concentrations and not used during training served as the test set. Agreement between manual thresholding and nnU-Net segmentation was assessed using pixel-wise Dice similarity coefficients. Dice scores were calculated separately for CPE and monolayer classes and averaged per well. Virus-level summary statistics were computed by pooling Dice scores across all wells belonging to each virus. Standard deviations reflect variability across wells.
Supporting information
S1 Fig. Agreement between cytopathic effect (CPE) area assay and traditional 6-well plaque assay.
Bland–Altman plots comparing viral titers quantified by the CPE area assay and 6-well plaque assay for Rift Valley fever virus infection plates. (A) Plate 1. (B) Plate 2. Titers were analyzed on a log10 scale. The middle horizontal line represents the mean difference, and dashed lines indicate the 95% limits of agreement (mean difference ± 1.96 standard deviations).
https://doi.org/10.1371/journal.pcbi.1013511.s001
(PNG)
S2 Fig. Siamese neural network Rift Valley fever virus test set.
Initial test split composed of images from the same plates used in the training and validation sets.
https://doi.org/10.1371/journal.pcbi.1013511.s002
(TIF)
Acknowledgments
The authors thank Anya Crane (Integrated Research Facility at Fort Detrick, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Fort Detrick, Frederick, MD, USA) for critically editing the manuscript and Jiro Wada (Integrated Research Facility at Fort Detrick, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Fort Detrick, Frederick, MD, USA) for preparing figures.
References
- 1. Payne S. Methods to Study Viruses. Viruses. Elsevier. 2017. p. 37–52.
- 2. Dulbecco R. Production of Plaques in Monolayer Tissue Cultures by Single Particles of an Animal Virus. Proc Natl Acad Sci U S A. 1952;38(8):747–52. pmid:16589172
- 3. Keiser PT, Anantpadma M, Staples H, Carrion R, Davey RA. Automation of Infectious Focus Assay for Determination of Filovirus Titers and Direct Comparison to Plaque and TCID50 Assays. Microorganisms. 2021;9(1):156. pmid:33445537
- 4. Liu T, Li Y, Koydemir HC, Zhang Y, Yang E, Eryilmaz M, et al. Rapid and stain-free quantification of viral plaque via lens-free holography and deep learning. Nat Biomed Eng. 2023;7(8):1040–52. pmid:37349390
- 5. Phanomchoeng G, Kukiattikoon C, Plengkham S, Boonyasuppayakorn S, Salakij S, Poomrittigul S, et al. Machine-learning-based automated quantification machine for virus plaque assay counting. PeerJ Comput Sci. 2022;8:e878. pmid:35494866
- 6.
Albrecht T, Fons M, Boldogh I, Rabson AS. Effects on Cells. In: Baron S, editor. Medical Microbiology. Galveston (TX): University of Texas Medical Branch at Galveston.
- 7. Reed LJ, Muench H. A simple method of estimating fifty per cent endpoints. Am J Epidemiol 1938;27(3):493–97.
- 8. Hochdorfer D, Businger R, Hotter D, Seifried C, Solzin J. Automated, label-free TCID50 assay to determine the infectious titer of virus-based therapeutics. Journal of Virological Methods. 2022;299:114318.
- 9. Moen E, Bannon D, Kudo T, Graf W, Covert M, Van Valen D. Deep learning for cellular image analysis. Nat Methods. 2019;16(12):1233–46. pmid:31133758
- 10. Petkidis A, Andriasyan V, Murer L, Volle R, Greber UF. A versatile automated pipeline for quantifying virus infectivity by label-free light microscopy and artificial intelligence. Nat Commun. 2024;15(1):5112. pmid:38879641
- 11. Wang T-E, Chao T-L, Tsai H-T, Lin P-H, Tsai Y-L, Chang S-Y. Differentiation of Cytopathic Effects (CPE) induced by influenza virus infection using deep Convolutional Neural Networks (CNN). PLoS Comput Biol. 2020;16(5):e1007883. pmid:32401790
- 12. Shurtleff AC, Bloomfield HA, Mort S, Orr SA, Audet B, Whitaker T, et al. Validation of the Filovirus Plaque Assay for Use in Preclinical Studies. Viruses. 2016;8(4):113. pmid:27110807
- 13. Toister E, Cherry L, Lupu E, Monash A, Dor E, Levin L, et al. Development and Validation of a Plaque Assay to Determine the Titer of a Recombinant Live-Attenuated Viral Vaccine for SARS-CoV-2. Vaccines (Basel). 2024;12(4):374. pmid:38675756
- 14.
WHO. WHO Guidelines on viral inactivation and removal procedures intended to assure the viral safety of human blood plasma products. 2004.
- 15. Bromley J, Bentz JW, Bottou L, Guyon I, Lecun Y, Moore C, et al. Signature Verification Using A “siamese” Time Delay Neural Network. Series in Machine Perception and Artificial Intelligence. World Scientific. 1994. p. 25–44.
- 16.
Chicco D. Siamese Neural Networks: An Overview, bookTitle= Artificial Neural Networks. New York, NY: Springer US, 2021.
- 17. Krizhevsky A, Sutskever I, Hinton GE. ImageNet classification with deep convolutional neural networks. Commun ACM. 2017;60(6):84–90.
- 18.
Dosovitskiy A, Beyer L, Kolesnikov A, et al. An image is worth 16x16 words: transformers for image recognition at scale. International Conference on International Conference on Learning Representations (ICLR 2021). https://openreview.net/forum?id=YicbFdNTTy 2025.
- 19. Isensee F, Jaeger PF, Kohl SAA, Petersen J, Maier-Hein KH. nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation. Nat Methods. 2021;18(2):203–11. pmid:33288961
- 20. Dixon WJ. Processing Data for Outliers. Biometrics. 1953;9(1):74.
- 21. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10. pmid:2868172
- 22.
Seabold S, Perktold J. Statsmodels: Econometric and statistical modeling with python. 2010.