Peer Review History
| Original SubmissionOctober 30, 2025 |
|---|
|
PCOMPBIOL-D-25-02241 Integrated multi-modal data analysis for computational modeling of healthy and location-dependent myocardial infarction conditions in porcine hearts PLOS Computational Biology Dear Dr. Rosales, Thank you for submitting your manuscript to PLOS Computational Biology. After careful consideration, we feel that it has merit but does not fully meet PLOS Computational Biology's publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Feb 02 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at ploscompbiol@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pcompbiol/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript: * A letter that responds to each point raised by the editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. This file does not need to include responses to formatting updates and technical items listed in the 'Journal Requirements' section below. * A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. * An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, competing interests statement, or data availability statement, please make these updates within the submission form at the time of resubmission. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter We look forward to receiving your revised manuscript. Kind regards, Andrew D. McCulloch, Ph.D. Academic Editor PLOS Computational Biology Marc Birtwistle Section Editor PLOS Computational Biology Journal Requirements: 1) We ask that a manuscript source file is provided at Revision. Please upload your manuscript file as a .doc, .docx, .rtf or .tex. If you are providing a .tex file, please upload it under the item type u2018LaTeX Source Fileu2019 and leave your .pdf version as the item type u2018Manuscriptu2019. 2) We noticed that you used the phrase 'data not shown' in the manuscript. We do not allow these references, as the PLOS data access policy requires that all data be either published with the manuscript or made available in a publicly accessible database. Please amend the supplementary material to include the referenced data or remove the references. 3) Please upload all main figures as separate Figure files in .tif or .eps format. For more information about how to convert and format your figure files please see our guidelines: https://journals.plos.org/ploscompbiol/s/figures 4) Some material included in your submission may be copyrighted. According to PLOSu2019s copyright policy, authors who use figures or other material (e.g., graphics, clipart, maps) from another author or copyright holder must demonstrate or obtain permission to publish this material under the Creative Commons Attribution 4.0 International (CC BY 4.0) License used by PLOS journals. Please closely review the details of PLOSu2019s copyright requirements here: PLOS Licenses and Copyright. If you need to request permissions from a copyright holder, you may use PLOS's Copyright Content Permission form. Please respond directly to this email and provide any known details concerning your material's license terms and permissions required for reuse, even if you have not yet obtained copyright permissions or are unsure of your material's copyright compatibility. Once you have responded and addressed all other outstanding technical requirements, you may resubmit your manuscript within Editorial Manager. Potential Copyright Issues: - Please confirm (a) that you are the photographer of Figure 1, or (b) provide written permission from the photographer to publish the photo(s) under our CC BY 4.0 license. - Figure 1. Please confirm whether you drew the images / clip-art within the figure panels by hand. If you did not draw the images, please provide (a) a link to the source of the images or icons and their license / terms of use; or (b) written permission from the copyright holder to publish the images or icons under our CC BY 4.0 license. Alternatively, you may replace the images with open source alternatives. See these open source resources you may use to replace images / clip-art: - https://commons.wikimedia.org 5) Please ensure that the funders and grant numbers match between the Financial Disclosure field and the Funding Information tab in your submission form. Note that the funders must be provided in the same order in both places as well. State the initials, alongside each funding source, of each author to receive each grant. For example: "This work was supported by the National Institutes of Health (####### to AM; ###### to CJ) and the National Science Foundation (###### to AM).". If you did not receive any funding for this study, please simply state: u201cThe authors received no specific funding for this work.u201d Reviewers' comments: Reviewer's Responses to Questions Comments to the Authors: Please note here if the review is uploaded as an attachment. Reviewer #1: Rosales et al. build sophisticated computer models of pig cardiac electrophysiology based on rich experimental data sets including myocardial infarction. They then study the sensitivity of selected simulation results (activation times, conduction velocity, ECG) on specific model parameters. Some of them are tuned then and a few comparisons to measured data are shown for validation purposes. The manuscript is very extensive; in general well written and supported by helpful figures an tables. My main comments are as follows: The added value of this study could be carved out more clearly. The three specific goals mentioned are not fully adequate in my opinion Goal 1: Why "to guide the development"? In my view you actually develop such models in the present study. Goal 2: porcine-specific (in general) or specific to an individual pig? Goal 3: "clinical application" is an overstatement in my opinion as most readers would likely assume application to humans The added value of the developed models remains vaguely described. There is mention of supporting the 3R principles but no concrete ways in which this could be achived are mentioned. I am surprised that there is little ST deviation (elevation or depression) visibile in the infarction ECGs (Fig. 11). l. 190: How much beat-to-beat variability did you observe in the activation and APD90 values? l. 322: "These porcine-specific pig-wise values of LDC and gK1 defined the mean values that were used in cases where personalization was not possible due to the lack of electrophysiological data." Unclear to me It is a pity that ECG is only available for two of the pigs. This would be a very valuable resource for model validation. Does the need for separate alignment of QRS complexes and T-waves indicate thate AP duration / morphology is not well matched between simulations and experiments? Fig. 7: What is the reason for V6 being negative in all simulations whereas it is positive in the experimental recording? The data acquisition and processing for this study is a major effort. How were the cine CMR data described in section 2.2.1 used? I have the impression that only the end-diastolic state was used. Code and model setups are available, which is comendable. What about the raw data? It seems that a huge part of the effort is related to data acquisition and not all of them were used, so it would be a pity if others couldn't build on it. The manuscript makes use of so many abbreviations that it is hard to remember all of them, which makes following the results section tedious, e.g. "At small PMJ radii as 0.1 mm, ncPMJ was low (28.5% for be-CS, 10.4% for bi-CS), resulting in limited aPMJ (28% for be-CS, 7% for bi-CS)." The same applies to many figure captions, which are full of abbreviations preventing the reader to interpret the figure without having found and memorized all abbreviations. Figure 10 for example is uninterpretable to me without a list of abbreviations (in mind). Further comments: I would advise to avoid the term "personalized" when referring to pigs rather than persons. "Individualized" might be an alternative. The Cardiac Electrophysiological Simulation Challenge (CESC10); Camara et al., Prog Biophys Mol Bio 2011 and the CRT-EPIGGY19 https://crt-epiggy19.surge.sh seem worthwhile discussing in the context of this work. l. 140: What are "custom-designed ad hoc containers"? Why did you use the multi-diffusion approach to differentiate the different transmural layer and not also a Laplace solution as for the apico-basal gradient? l. 380: Is there experimental evidence that spatial APD heterogeneity in pigs is due to differential expression of IK1? Table 3 misses units l. 392: "80-µA/cm2" -> "80 µA/cm2"? l. 398: I thought optical mapping data were used to parametrize APD, how can it be used for validation then? Section 3.5 also mentions that optical mapping data were used to calibrate border zone electrophysiology. Please clarify. Fig. 6b: It is not obvious at first sight why there is only 1 "exp" trace if there are 3 pigs. From Table 1 it becomes clear that this is not a 1:1 comparison. This should be highlighted in the figure caption. Fig. 9 should clearly indicate the scar region (which should not be activated at all as I understand). "Personalized fiber orientation" can be misleading as you did not personalize the entire fiber field but only one endocardial and one epicardial angle per ventricle as I understand. Reviewer #2: Reviewer Comments General Evaluation This manuscript presents an ambitious whole-organ porcine digital-twin electrophysiology framework informed by high-quality imaging and electrophysiological measurements. The integration of fiber architecture, infarct structure, repolarization heterogeneity, and anatomical conduction system (CS) modeling is a strength, and the authors have assembled an exceptional experimental dataset from intact organs. However, several methodological details require clarification, and some modelling assumptions rely on human or canine literature rather than porcine-specific measurements. The manuscript would benefit from clearer justification of those modelling choices, additional methodological transparency, and discussion of model validation requirements for future clinical translation. Specific Comments Abstract • The similarity metric reported as: “Accurate CS and repolarization heterogeneities reproduced depolarization (0.76 QRS similarity) and repolarization (0.74 T-wave similarity) patterns.” should specify the calculation method (Pearson correlation). Without this information, the interpretation of the similarity values is unclear. Scope and Framing of the Study • The current framing presents the work largely as a modelling workflow rather than addressing either: o a biological hypothesis, or o an engineering performance target. As written, the contribution sits between those categories. Clarifying the intended purpose of the model (mechanistic exploration, validation framework, clinical translation tool, or proof-of-feasibility) would help position the work appropriately. Data • Table 1 presents highly heterogeneous sample characteristics. The authors should comment on whether this variability was expected, and whether it impacts personalization steps or parameter calibration. It was not clear to me how data was combined (or not) to form a digital twin of a specific pig. Or is this more a model of a representative pig? • Anatomical Model • The mesh excludes the base of the heart. As the base is often the last region activated, it is unclear how this omission may affect the predicted QRS duration or conduction velocity calibration. Clarifying whether conduction was artificially slowed to compensate, or whether truncation explains QRS morphology mismatches, would strengthen the modelling justification. Segmentation and Image Processing • The statement: “In MI cases, AZ and HZ were manually identified from the automatic deep learning–based segmentations…” appears contradictory. It would help to clarify whether the method is: o fully manual, o fully automated, or o automated with manual correction. Electrophysiology Model Construction A number of model components originate from non-porcine literature: Component Source species Sodium channel (gNa) remodeling Human [11,16] and canine [48] Stewart Purkinje model Human [44] Conduction system conductivity Human estimates [43] Border zone remodeling Human and canine Transmural repolarization gradients Human [51,52] Because these choices may influence behaviour, the authors should comment on: • expected inter-species electrophysiological differences, • whether porcine-specific measurements are planned or needed, • and whether substitution of human/canine parameters may bias conduction or repolarization dynamics. APD Heterogeneity Strategy • A sensitivity analysis on the imposed apex–base and transmural heterogeneity would be valuable, particularly because some transitions are implemented as discrete step changes rather than smooth gradients. It is unclear whether such abrupt transitions are physiologically plausible. • Prior work (e.g., Camps J et al. Medical Image Analysis) implemented APD heterogeneity using IKs modulation in human models. Qian Nat Card Res used both Iks and Ikr in 3000+ cases. Gillete used Ikr. • Discussion is warranted on whether: o Kgr/gks modulation reflects species differences, o a difference in underlying ion-channel experimental evidence, o or a constraint of the specific porcine cellular model used. Model Interpretation and Reporting • Table 4 is difficult to interpret because several abbreviations and labels (e.g., s, b, a) are not defined. This prevents clear understanding of how spatial personalization was applied. • The statement that “74 simulations were performed” requires clarification. Is this total across all pigs, or per animal? Similarity Metric • The Pearson correlation coefficient is a parametric measure. If used as a statistical inference tool, normality should be tested, or a non-parametric alternative considered. • If it is intended purely as a signal similarity score, this should be stated explicitly and not framed as a hypothesis-testing metric. Model Validation and Tolerances • The manuscript would benefit from explicitly defining a use case for the model and the corresponding: o how accuracy is assessed, o what constitutes acceptable error for intended use, and o whether the model meets those thresholds. • The authors should include a sensitivity analysis, particularly in light of the non-porcine input parameters. ********** Have the authors made all data and (if applicable) computational code underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data and code underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data and code should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data or code —e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: No: No raw data available Reviewer #2: No: There is no reason not to make the images, ECG and meshes available. I did not see a data link ********** PLOS authors have the option to publish the peer review history of their article (what does this mean? ). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy . Reviewer #1: No Reviewer #2: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] Figure resubmission: While revising your submission, we strongly recommend that you use PLOS’s NAAS tool (https://ngplosjournals.pagemajik.ai/artanalysis) to test your figure files. NAAS can convert your figure files to the TIFF file type and meet basic requirements (such as print size, resolution), or provide you with a report on issues that do not meet our requirements and that NAAS cannot fix. After uploading your figures to PLOS’s NAAS tool - https://ngplosjournals.pagemajik.ai/artanalysis, NAAS will process the files provided and display the results in the "Uploaded Files" section of the page as the processing is complete. If the uploaded figures meet our requirements (or NAAS is able to fix the files to meet our requirements), the figure will be marked as "fixed" above. If NAAS is unable to fix the files, a red "failed" label will appear above. When NAAS has confirmed that the figure files meet our requirements, please download the file via the download option, and include these NAAS processed figure files when submitting your revised manuscript. Reproducibility: To enhance the reproducibility of your results, we recommend that authors of applicable studies deposit laboratory protocols in protocols.io, where a protocol can be assigned its own identifier (DOI) such that it can be cited independently in the future. Additionally, PLOS ONE offers an option to publish peer-reviewed clinical study protocols. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols |
| Revision 1 |
|
PCOMPBIOL-D-25-02241R1 Integrated multi-modal data analysis for computational modeling of healthy and location-dependent myocardial infarction conditions in porcine hearts PLOS Computational Biology Dear Dr. Rosales, Thank you for submitting your manuscript to PLOS Computational Biology. After careful consideration, we feel that it has merit but does not fully meet PLOS Computational Biology's publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Apr 12 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at ploscompbiol@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pcompbiol/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript: * A letter that responds to each point raised by the editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. This file does not need to include responses to formatting updates and technical items listed in the 'Journal Requirements' section below. * A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. * An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, competing interests statement, or data availability statement, please make these updates within the submission form at the time of resubmission. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. We look forward to receiving your revised manuscript. Kind regards, Marc Birtwistle Section Editor PLOS Computational Biology Additional Editor Comments: Please confirm the materials are available in zenodo, reinforce the biological understanding that is gleaned and can be obtained using this computational advance (that was not before possible), and attend to the remaining concern of Reviewer 1. Reviewers' comments: Reviewer's Responses to Questions Comments to the Authors: Please note here if the review is uploaded as an attachment. Reviewer #1: Thank your for addressing my points and improving the manuscript. I have one remaining point concerning beat-to-beat variability (#1 in my initial review): I think it would be important to mention the experimental beat-to-beat variability that remains after quite strict beat selection (median standard deviation across pixels: 20.5ms for activation and 51.5ms for APD90 in pig 13) to i) put the remaining deviation during parameter tuning into perspective (doesn't make sense to aim for sub-milisecond precision during tuning when measurement variability/uncertainty is in the range of dozens of miliseconds); ii) highlight that while some of the observed variability is probably due to measurement uncertainty, there is very likely a contribution of intrinsic beat-to-beat variability as well, which is not considered in the model. Reviewer #2: My concerns have largely been addressed. The manuscript would be further strengthened by more clearly articulating the specific biological question(s) that this modeling framework is intended to address. ********** Have the authors made all data and (if applicable) computational code underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data and code underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data and code should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data or code —e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** PLOS authors have the option to publish the peer review history of their article (what does this mean? ). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy . Reviewer #1: No Reviewer #2: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] Figure resubmission: While revising your submission, we strongly recommend that you use PLOS’s NAAS tool (https://ngplosjournals.pagemajik.ai/artanalysis) to test your figure files. NAAS can convert your figure files to the TIFF file type and meet basic requirements (such as print size, resolution), or provide you with a report on issues that do not meet our requirements and that NAAS cannot fix. After uploading your figures to PLOS’s NAAS tool - https://ngplosjournals.pagemajik.ai/artanalysis, NAAS will process the files provided and display the results in the "Uploaded Files" section of the page as the processing is complete. If the uploaded figures meet our requirements (or NAAS is able to fix the files to meet our requirements), the figure will be marked as "fixed" above. If NAAS is unable to fix the files, a red "failed" label will appear above. When NAAS has confirmed that the figure files meet our requirements, please download the file via the download option, and include these NAAS processed figure files when submitting your revised manuscript. Reproducibility: To enhance the reproducibility of your results, we recommend that authors of applicable studies deposit laboratory protocols in protocols.io, where a protocol can be assigned its own identifier (DOI) such that it can be cited independently in the future. Additionally, PLOS ONE offers an option to publish peer-reviewed clinical study protocols. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols |
| Revision 2 |
|
Dear Mr Rosales, We are pleased to inform you that your manuscript 'Integrated multi-modal data analysis for computational modeling of healthy and location-dependent myocardial infarction conditions in porcine hearts' has been provisionally accepted for publication in PLOS Computational Biology. Before your manuscript can be formally accepted you will need to complete some formatting changes, which you will receive in a follow up email. A member of our team will be in touch with a set of requests. Please note that your manuscript will not be scheduled for publication until you have made the required changes, so a swift response is appreciated. IMPORTANT: The editorial review process is now complete. PLOS will only permit corrections to spelling, formatting or significant scientific errors from this point onwards. Requests for major changes, or any which affect the scientific understanding of your work, will cause delays to the publication date of your manuscript. Should you, your institution's press office or the journal office choose to press release your paper, you will automatically be opted out of early publication. We ask that you notify us now if you or your institution is planning to press release the article. All press must be co-ordinated with PLOS. Thank you again for supporting Open Access publishing; we are looking forward to publishing your work in PLOS Computational Biology. Best regards, Marc Birtwistle Section Editor PLOS Computational Biology *********************************************************** Reviewer's Responses to Questions Comments to the Authors: Please note here if the review is uploaded as an attachment. Reviewer #1: My remaining comments has been addressed. Congratulations on this study! ********** Have the authors made all data and (if applicable) computational code underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data and code underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data and code should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data or code —e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes ********** PLOS authors have the option to publish the peer review history of their article (what does this mean? ). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy . Reviewer #1: No |
| Formally Accepted |
|
PCOMPBIOL-D-25-02241R2 Integrated multi-modal data analysis for computational modeling of healthy and location-dependent myocardial infarction conditions in porcine hearts Dear Dr Rosales, I am pleased to inform you that your manuscript has been formally accepted for publication in PLOS Computational Biology. Your manuscript is now with our production department and you will be notified of the publication date in due course. The corresponding author will soon be receiving a typeset proof for review, to ensure errors have not been introduced during production. Please review the PDF proof of your manuscript carefully, as this is the last chance to correct any errors. Please note that major changes, or those which affect the scientific understanding of the work, will likely cause delays to the publication date of your manuscript. Soon after your final files are uploaded, unless you have opted out, the early version of your manuscript will be published online. The date of the early version will be your article's publication date. The final article will be published to the same URL, and all versions of the paper will be accessible to readers. For Research, Software, and Methods articles, you will receive an invoice from PLOS for your publication fee after your manuscript has reached the completed accept phase. If you receive an email requesting payment before acceptance or for any other service, this may be a phishing scheme. Learn how to identify phishing emails and protect your accounts at https://explore.plos.org/phishing. Thank you again for supporting PLOS Computational Biology and open-access publishing. We are looking forward to publishing your work! With kind regards, Anita Estes PLOS Computational Biology | Carlyle House, Carlyle Road, Cambridge CB4 3DN | United Kingdom ploscompbiol@plos.org | Phone +44 (0) 1223-442824 | ploscompbiol.org | @PLOSCompBiol |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .