Understanding the hemodynamic changes in fetuses with coarctation of the aorta using a lumped model of fetal circulation

PLOS Computational Biology

Dear Dr. Villanueva Baxarias,

Thank you for submitting your manuscript to PLOS Computational Biology. After careful consideration, we feel that it has merit but does not fully meet PLOS Computational Biology's publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

Please submit your revised manuscript within 60 days Mar 11 2025 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at ploscompbiol@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pcompbiol/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

* A rebuttal letter that responds to each point raised by the editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. This file does not need to include responses to formatting updates and technical items listed in the 'Journal Requirements' section below.

* A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.

* An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, competing interests statement, or data availability statement, please make these updates within the submission form at the time of resubmission. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter

We look forward to receiving your revised manuscript.

Kind regards,

Andrew D. McCulloch, Ph.D.

Academic Editor

PLOS Computational Biology

Marc Birtwistle

Section Editor

PLOS Computational Biology

Journal Requirements:

1) Please ensure that the CRediT author contributions listed for every co-author are completed accurately and in full.

At this stage, the following Authors/Authors require contributions: Maria Inmaculada Villanueva Baxarias, Anna Pellisé-Tintoré, María Pérez, Laura Nogué, Pooja Vaziraani, Iris Soveral, Fàtima Crispi, Olga Gómez, Patricia Garcia-Canadilla, Oscar Camara, Bart Bijnens, and Gabriel Bernardino. Please ensure that the full contributions of each author are acknowledged in the "Add/Edit/Remove Authors" section of our submission form.

The list of CRediT author contributions may be found here: https://journals.plos.org/ploscompbiol/s/authorship#loc-author-contributions

2) Thank you for including an Ethics Statement for your study. Please include:

i) The full name(s) of the Institutional Review Board(s) or Ethics Committee(s).

3) Please upload a copy of Fig D.1 which you refer to in your text on page 19. Or, if the figure is no longer to be included as part of the submission please remove all reference to it within the text.

4) We have noticed that you have uploaded Supporting Information files, but you have not included a complete list of legends. Please add a full list of legends for Appendix S1-S3 after the references list.

5) We notice that your supplementary figures are uploaded with the file type 'Figure'. Please amend the file type to 'Supporting Information'. Please ensure that each Supporting Information file has a legend listed in the manuscript after the references list.

6) Some material included in your submission may be copyrighted. According to PLOSu2019s copyright policy, authors who use figures or other material (e.g., graphics, clipart, maps) from another author or copyright holder must demonstrate or obtain permission to publish this material under the Creative Commons Attribution 4.0 International (CC BY 4.0) License used by PLOS journals. Please closely review the details of PLOSu2019s copyright requirements here: PLOS Licenses and Copyright. If you need to request permissions from a copyright holder, you may use PLOS's Copyright Content Permission form.

Please respond directly to this email and provide any known details concerning your material's license terms and permissions required for reuse, even if you have not yet obtained copyright permissions or are unsure of your material's copyright compatibility. Once you have responded and addressed all other outstanding technical requirements, you may resubmit your manuscript within Editorial Manager. 

Potential Copyright Issues:

i) Figure 4. Please confirm whether you drew the images / clip-art within the figure panels by hand. If you did not draw the images, please provide (a) a link to the source of the images or icons and their license / terms of use; or (b) written permission from the copyright holder to publish the images or icons under our CC BY 4.0 license. Alternatively, you may replace the images with open source alternatives. See these open source resources you may use to replace images / clip-art:

- https://commons.wikimedia.org

- https://openclipart.org/.

7) In the online submission form, you indicated that "The data that support the findings of this study are available on request from the corresponding author. All PLOS journals now require all data underlying the findings described in their manuscript to be freely available to other researchers, either

1. In a public repository

2. Within the manuscript itself

3. Uploaded as supplementary information.

This policy applies to all data except where public deposition would breach compliance with the protocol approved by your research ethics board. If your data cannot be made publicly available for ethical or legal reasons (e.g., public availability would compromise patient privacy), please explain your reasons by return email and your exemption request will be escalated to the editor for approval. Your exemption request will be handled independently and will not hold up the peer review process, but will need to be resolved should your manuscript be accepted for publication. One of the Editorial team will then be in touch if there are any issues.

8) In the online submission form you indicate that your data is not available for proprietary reasons and have provided a contact point for accessing this data. Please note that your current contact point is a co-author on this manuscript. According to our Data Policy, the contact point must not be an author on the manuscript and must be an institutional contact, ideally not an individual. Please revise your data statement to a non-author institutional point of contact, such as a data access or ethics committee, and send this to us via return email. Please also include contact information for the third party organization, and please include the full citation of where the data can be found.

9) Please amend your detailed Financial Disclosure statement. This is published with the article. It must therefore be completed in full sentences and contain the exact wording you wish to be published.

1) State the initials, alongside each funding source, of each author to receive each grant. For example: "This work was supported by the National Institutes of Health (####### to AM; ###### to CJ) and the National Science Foundation (###### to AM)."

2) State what role the funders took in the study. If the funders had no role in your study, please state: "The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript."

10) Please ensure that the funders and grant numbers match between the Financial Disclosure field and the Funding Information tab in your submission form. Note that the funders must be provided in the same order in both places as well. Currently, this funder "European Social Fund Plus (FSE+)" is missing from the Funding Information tab. In addition, the order of the grants is different in both places.

Please indicate by return email the full and correct funding information for your study and confirm the order in which funding contributions should appear. Please be sure to indicate whether the funders played any role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript.

11) Population_characteristics.xlsx and Healthy_velocities.csv are currently uploaded as file type “Other”, which is not viewable by the reviewers. Please change the file type(s) to 'Supporting Information' and include a legend in the manuscript if you wish it/them to be included in review.

Reviewers' comments:

Reviewer's Responses to Questions

Reviewer #1: The manuscript applies an established lumped parameter model of the fetal cardiovascular system to explore the impact of geometric perturbations in the aortic isthmus (AoI), which is associated with coarctation of the aorta. The in silico model predicts certain robustness and adaptability of the fetal circulation to this pathophysiological condition and proposes the AoI diastolic velocity as a novel diagnostic indicator.

The authors are established experts in the field, and the manuscript is generally well-written and gives a good example of mechanistic insight into fetal pathophysiology supported by clinical data. Nonetheless, there are a few issues that should be addressed as suggested below.

Firstly, you state (p. 11) that “interactions between cardiovascular components without flow phenomena or wave reflections, [...] was sufficiently accurate for our purposes.”

Aren’t you concerned about the impact of potentially significant pulse wave reflections from the narrowed regions of the aorta? (see Cahill et al. eBioMed. 67, 103326 (2021) 10.1016/j.ebiom.2021.103326). Since the model deals with high Reynolds flows in the complex geometries of the aorta, would it be more appropriate to use distributed flow networks and/or hybrid 0D-1D-3D approaches (for example, Guettouche et al. [9] quoted by the authors, and also Wong et al. Ann. Biomed. Eng. 50, 1158 (2022) 10.1007/s10439-022-02990-5)? Please provide more evidence that these effects can be neglected.

Secondly, I am a bit surprised that the authors did not consult a highly relevant 2015 study of coarctication biomechanics by Zahra Keshavarz-Motamed and others (J. Biomech. 48, 4229,

10.1016/j.jbiomech.2015.10.017). In particular, I invite you to discuss Keshavarz-Motamed et al.’s observation that the trans-coarctation pressure drop is highly sensitive to compliance as well as cardiac output. Thus, the AoI geometry alone could be insufficient to explain the mechanisms of this condition.

Finally, although the model is based on prior work by the authors, I would expect further details on the model’s sensitivity to key parameters and comments on the associated uncertainty (please see examples in Marquis Math. Biosci. 304, 9 (2018) 10.1016/j.mbs.2018.07.001, and Mihaela J. R. Soc. Interface. 1720200886 (2020) 10.1098/rsif.2020.0886). This would increase the confidence in the model’s predictions and minimize the risk of overfitting to limited data.

Specific points

The Figures should be more clearly annotated, and the order could be confusing. For example, starting with Figure 4 and indicating the model parameters, which are being fitted and/or perturbed, would put the rest of the paper into proper context for the readership of this journal.

Figure 1 caption should be extended to explain how the baseline model was parametrized. Considering large variation in the measured control group, it would help to add a mean curve and shaded confidence intervals to aid the assessment. Furthermore, could you factor in the expected dispersion in the normal population when discussing the effect of altered aortic geometry and other CV parameters in Figs 2 & 3?

Page 11, l. 212. Please clarify what you mean by “blood pressure velocities”? There is no wave speed present in your model as far as I am aware.

Figure S3 (c) suggests that both min and max velocities are elevated. Does your model predict that the PI or RI indices are similar to the reference control? If so, what dimensionless index would you propose to detect this condition? Please also see the general point 2 above, which refers to the driving pressure gradient.

I recommend that the codes underpinning the modeled scenarios be made publicly available. Any personally identifiable data should be removed or replaced with aggregated or synthetic illustrations. Sufficient metadata should accompany the codes to allow for the reproduction of key figures and results.

Reviewer #2: Villanueva et al. present a study that develops a 0D mathematical model to simulate coarctation of the aorta (CoA) remodeling patterns. The study finds that mild aortic isthmus (AoI) narrowing (80% diameter) requires modest adaptations, while severe narrowing (20% diameter) necessitates significant right ventricular (RV) enlargement and ductus arteriosus (DA) dilation to maintain normal pressures, wall shear stresses, and organ perfusion. Validation with ultrasonographic data supports these findings. Notably, the study identifies specific changes in AoI flow patterns, such as delayed retrograde peaks and increased diastolic velocities, which could enhance early CoA diagnosis. However, despite these compensations, overall fetal hemodynamics, including blood pressure and velocities, remain largely unaltered, except for AoI-specific changes.

The specific comments and questions are:

Discussion:

Line 156: It is observed in Fig. S1 A-B that extreme aortic narrowing could lead to overperfusion of the brain without ventricular disproportion. However, this interpretation may be misleading because Fig. S1 only considers two factors: ventricular disproportion and aortic narrowing. In real CoA patients, other compensatory factors (shown in Fig. 1), such as a dilated ductus arteriosus (DA), can alleviate brain overperfusion by reducing the right ventricular (RV) afterload. This should be acknowledged and discussed further.

Line 179: The authors emphasize that velocity patterns in the aortic isthmus show a delayed retrograde flow peak in Fig. 3, Row 3. However, on Fig. 1, there is already a phase difference in retrograde flow peaks among real healthy data.

Line 188 and similar instances: The study simulates "extreme CoA" patients using a mathematical model that incorporates many simplifications, such as assuming circular vessel lumens, constant vessel segment diameters, and no significant remodeling of vascular beds. Prior studies indicate that these assumptions may not hold true for extreme CoA cases, particularly given the dynamic remodeling observed in real patients. These limitations should be highlighted more explicitly.

Line 203: The authors claim that their model is "adequately accurate" but do not thoroughly address the general lack of accurate wall shear stress assessment in lumped parameter models. A more detailed discussion of this limitation is necessary.

Additional Limitation: The study is based on a small cohort, which is a critical limitation, especially considering that CoA is not an exceedingly rare congenital heart defect. A larger dataset would improve the model's robustness and generalizability.

Materials and Methods:

Line 253: The assumption that ventricular depths are comparable requires citation. This is crucial to substantiate the validity of this parameter in the model.

Line 288: The model is based on Pennati et al. (1997) and Garcia-Canadilla's models. However, Pennati’s model is over two decades old, and there have been significant advancements in closed-loop modeling, particularly in heart module development. The authors should justify their choice of an older model over newer approaches.

Line 289: Since the current model is a composite of several previous models, it is essential to describe it in detail in supplementary materials. This would provide transparency and facilitate reproducibility.

Line 297: The non-linear effect described for the AoI compartment should be specified with the corresponding equation to enhance clarity and reproducibility.

Line 310: The middle cerebral artery is described in the text but not depicted in the schematic drawing in Fig. 4. This discrepancy should be addressed for consistency.

Line 342: The authors state that compliance is proportional to the square of the diameter, but Garcia’s earlier work (2014) used a cubic relationship. The justification for this change should be provided.

Line 359: Maximum wall shear stress is calculated using 4μQ/r3, which assumes steady flow conditions. However, fetal circulation is pulsatile, as evidenced by the higher pulsatility indices in CoA patients (Table 1). A wall shear stress equation appropriate for pulsatile conditions should be considered.

Line 375: The validation of the model against real healthy and CoA cases in Fig. 2 should be elaborated upon, including more detailed results and limitations.

Line 383: Details on how ventricular disproportion is simulated are sparse. More information should be provided.

Figures

Figure 1:

This figure validates the mathematical model against real healthy data but lacks validation against real CoA data. Models can often replicate the conditions they are based on (e.g., healthy state), but their validity in other states (e.g., CoA) remains uncertain.

The control group used for validation spans a gestational age range of 6 weeks (31.8 ± 2.89 weeks), which likely includes significant hemodynamic variability due to fetal growth. Normalization or categorization by gestational age is necessary to improve accuracy.

Even for healthy data, the AoI validation, a central focus of this study, does not match real data adequately.

Figure 4:

The meaning of dashed connections should be clarified. Do they represent specific characteristics or assumptions in the model?

The inclusion of specific organs (e.g., kidney, liver, intestines, legs) as separate vascular beds rather than lumping them raises questions. If clinical data were collected for these organs, this should be explicitly stated and validated.

Additional Comments

Data Sharing: A clear data-sharing plan is missing. To enhance reproducibility and foster collaboration, consider providing anonymized datasets or simulation codes through an open-access platform.

In Appendix S1

Line 9 “Moreover, according to Gallivan et al., W (in grams) and GA (in weeks) in healthy human fetuses are related by

log_10⁡W=0.2508+0.1458·GA-0.0016·GA^2.

Comments:

This equation appears to have been derived from data presented in previous literature. To enhance clarity and credibility, it would be beneficial to include the original data in a table or diagram, alongside the curve fitting obtained in the current study.

Additionally, it seems there may be a typographical error, as “Gallivan et al.” does not appear to be cited properly.

Line 19: “Due to their unusual diameter growth, peculiar locations, and functions in the fetal cardiovascular system, the scaling factors of the non-linear resistances in the ductus venosus, ductus arteriosus, and foramen ovale were set to -0.88, -2.5, and -0.6, respectively.”

What is the fluid mechanics rationale for setting the scaling factors of the non-linear resistances in the ductus venosus, ductus arteriosus, and foramen ovale to -0.88, -2.5, and -0.6, respectively?

**********

Have the authors made all data and (if applicable) computational code underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data and code underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data and code should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data or code —e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: No:  No links to relevant code repositories were provided. Please see the feedback to the authors for more details.

Reviewer #2: None

**********

PLOS authors have the option to publish the peer review history of their article (what does this mean? ). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy .

Reviewer #1: No

Reviewer #2: No

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

Figure resubmission:

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. If there are other versions of figure files still present in your submission file inventory at resubmission, please replace them with the PACE-processed versions.

Reproducibility:

To enhance the reproducibility of your results, we recommend that authors of applicable studies deposit laboratory protocols in protocols.io, where a protocol can be assigned its own identifier (DOI) such that it can be cited independently in the future. Additionally, PLOS ONE offers an option to publish peer-reviewed clinical study protocols. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols

Revision 1

Attachments
Attachment
Submitted filename: Rebuttal_letter.docx
Decision Letter - Andrew D. McCulloch, Editor, Marc R Birtwistle, Editor

Dear Ms Villanueva Baxarias,

We are pleased to inform you that your manuscript 'Understanding the hemodynamic changes in fetuses with coarctation of the aorta using a lumped model of fetal circulation' has been provisionally accepted for publication in PLOS Computational Biology.

Before your manuscript can be formally accepted you will need to complete some formatting changes, which you will receive in a follow up email. A member of our team will be in touch with a set of requests.

Please note that your manuscript will not be scheduled for publication until you have made the required changes, so a swift response is appreciated.

IMPORTANT: The editorial review process is now complete. PLOS will only permit corrections to spelling, formatting or significant scientific errors from this point onwards. Requests for major changes, or any which affect the scientific understanding of your work, will cause delays to the publication date of your manuscript.

Should you, your institution's press office or the journal office choose to press release your paper, you will automatically be opted out of early publication. We ask that you notify us now if you or your institution is planning to press release the article. All press must be co-ordinated with PLOS.

Thank you again for supporting Open Access publishing; we are looking forward to publishing your work in PLOS Computational Biology. 

Best regards,

Andrew D. McCulloch, Ph.D.

Academic Editor

PLOS Computational Biology

Marc Birtwistle

Section Editor

PLOS Computational Biology

***********************************************************

Reviewer's Responses to Questions

Comments to the Authors:

Please note here if the review is uploaded as an attachment.

Reviewer #1: Thank you for your careful revision of the manuscript, which has markedly improved. I recommend that the authors clarify that their model operates at moderate Reynolds numbers and ideally provide a numerical range, since "low Reynolds numbers" (l. 421, p. 21) typically refer to Re much less than 1. Also, I believe you meant to refer to Fig. S3, not Fig. S5, in the Uncertainty Analysis section (Appendix S1, l. 92). I do not have any further comments.

**********

Have the authors made all data and (if applicable) computational code underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data and code underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data and code should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data or code —e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

**********

PLOS authors have the option to publish the peer review history of their article (what does this mean? ). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy .

Reviewer #1: No

Formally Accepted
Acceptance Letter - Andrew D. McCulloch, Editor, Marc R Birtwistle, Editor

PCOMPBIOL-D-24-01800R1

Understanding the hemodynamic changes in fetuses with coarctation of the aorta using a lumped model of fetal circulation

Dear Dr Villanueva-Baxarias,

I am pleased to inform you that your manuscript has been formally accepted for publication in PLOS Computational Biology. Your manuscript is now with our production department and you will be notified of the publication date in due course.

The corresponding author will soon be receiving a typeset proof for review, to ensure errors have not been introduced during production. Please review the PDF proof of your manuscript carefully, as this is the last chance to correct any errors. Please note that major changes, or those which affect the scientific understanding of the work, will likely cause delays to the publication date of your manuscript.

Soon after your final files are uploaded, unless you have opted out, the early version of your manuscript will be published online. The date of the early version will be your article's publication date. The final article will be published to the same URL, and all versions of the paper will be accessible to readers.

Thank you again for supporting PLOS Computational Biology and open-access publishing. We are looking forward to publishing your work!

With kind regards,

Anita Estes

PLOS Computational Biology | Carlyle House, Carlyle Road, Cambridge CB4 3DN | United Kingdom ploscompbiol@plos.org | Phone +44 (0) 1223-442824 | ploscompbiol.org | @PLOSCompBiol

Open letter on the publication of peer review reports

PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.

We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.

Learn more at ASAPbio .