Figure 1.

The Forward and Inverse Problems

Illustration of the role of a mechanistic mathematical model in linking measurements with abstract quantitative representations of the underlying physiological processes. Sources of stochasticity are indicated both for forward/predictive use of the model and inverse/inference use. The forward problem consists of predicting (distributions of) observations if (distributions of) initial conditions and model parameters are known. The inverse problem refers to the task of inferring (distributions of) initial conditions and model parameters from observations. It is termed ill-posed if the available observations are insufficient to define a unique solution.

More »

Figure 1 Expand

Figure 2.

Schematic of the Simplified Model of the Cardiovascular System and Its Control

Blood is driven from the venous compartment with volume Vv to the arterial compartment with volume Va by the monoventricular heart, which contracts from its end-diastolic volume VED to its end-systolic volume VES. Reverse flow is prevented by a valve with resistance Rvalve. To complete the systemic circulation, flow from the arterial to the venous compartment has to overcome the total peripheral resistance RTPR. Baroreflex senses pressure Pa in the arterial compartment, and it processes the set point deviation through a sigmoidal nonlinearity and a linear element with low-pass characteristics, eventually affecting the actuators RTPR, unstressed venous volume , heart rate fHR, and myocardial contractility cPRSW. See text for details.

More »

Figure 2 Expand

Figure 3.

Starling Curves

Steady state stroke volume with inactive baroreflex feedback loop as a function of venous pressure for various contractility factors c that linearly scale the range of the baroreflex contractility effector branch . Simulations were performed by varying total intravascular volume between 3,000 and 8,000 ml and plotting stroke volumes versus venous pressures after 600 s of simulated time.

More »

Figure 3 Expand

Figure 4.

Simulation of Fluid Withdrawal and Reinfusion

Fluid is drawn from or reinfused into the venous compartment at constant rate. Vertical lines indicate the beginning and end of withdrawal and reinfusion.

More »

Figure 4 Expand

Figure 5.

The Diagnostic Inference Process, Informative Priors

Probability densities for high-precision (standard deviation 10 mm Hg) (A) and low-precision (standard deviation 30 mm Hg) (B) measurements of blood pressure for Gaussian prior densities. (A,B1) show the assumed prior densities, (A,B2) show the posterior densities resulting from a single arterial pressure measurement of 25 mm Hg, (A,B3) show the posterior densities if subsequent to the initial measurement, 1,500 ml of fluid are applied intravenously resulting in a pressure measurement of 30 mm Hg, while (A,B4) show the posterior densities if the measurement after fluid application is 70 mm Hg.

More »

Figure 5 Expand

Figure 6.

The Diagnostic Inference Process, Uniform Priors

Probability densities for high-precision (standard deviation 10 mm Hg) (A) and low-precision (standard deviation 30 mm Hg) (B) measurements of blood pressure for uniform prior densities. The panel assignments are analogous to Figure 6. Note that the axes are scaled differently due to the narrower support of the (compactly supported) priors used.

More »

Figure 6 Expand

Figure 7.

Three-Dimensional Inference

Posterior probability densities for post-resuscitation observations of 30 mm Hg (A), 50 mm Hg (B), and 70 mm Hg (C) mean arterial blood pressure. The left column depicts densities at grid-points corresponding to 95% of the total probability mass, while the right column depicts the approximate surface enclosing this volume. The origin is in the far bottom corner for all figures. Shadows represent orthogonal projections to the contractility/total intravascular volume plane.

More »

Figure 7 Expand

Table 1.

Glossary of Variables and Parameters of the Cardiovascular Model

More »

Table 1 Expand

Figure 8.

Transient Behavior of Continuous Time Cardiac Model

Temporal evolution of actual stroke volume of continuous time system during initial transient of simulation shown in Figure 5 (solid line) and stroke volume calculated from systolic and end-diastolic volumes that would occur if the discrete dynamical system was advanced one step from the current values given by the continuous system (dashed line). Note that the state of the continuous system rapidly approaches a fixed point of the discrete dynamical system, resulting in superposition of the two curves. The transient is caused by starting integration with a non-equilibrium distribution of fluid between arterial and venous compartments.

More »

Figure 8 Expand

Figure 9.

End-Diastolic Pressure–Volume Relationship

Least squares fit of the empirical exponential pressure–volume relationship used to determine parameters from the experimental end-diastolic measurements from [40], Figure 6, bottom right panel.

More »

Figure 9 Expand

Table 2.

Parameter Values for the Model of the Cardiovascular System and their Sources

More »

Table 2 Expand