A three-dimensional shear dependent continuum model of platelet aggregation under flow
Fig 10
Shear-dependent adhesion and cohesion rates.
Functional forms of the shear dependence for adhesion and cohesion rates involving vWF, along with the corresponding flow rates over time, measured at the end of the injury channel. The blue shaded bar indicates the interquartile range of experimental values shown in Fig 9. Flow rates below the experimentally defined occlusion threshold are shown in gray. In the legend, Trunc and Hyp denote truncated and hyperbolic functional forms, respectively, and on/off indicate whether the form was applied to the associated on- or off-rate. Exp denotes exponential.