A quantitative physical model of the TMS-induced discharge artifacts in EEG

Fig 8

Effect of changing the sampling rate.

(A, B) Decreasing acquisition rate (16384 Hz, 8192 Hz, 4096 Hz, 2048 Hz, 1024 Hz) lead to a progressive time shift of the TMS artifacts and a decrease of TMS pulse artifact amplitude. The shifting time can be found by time-shifting the traces for each sampling rate backwards until they coincide with the 16 kHz traces. The optimal time is found when the sum of distances between these traces, evaluated directly after the pulse artifact, becomes minimal. The optimal times coincide for the watermelon and the human head (C). Note that time shifting will not change power law decay tails as can also be seen in (D).

Fig 8

doi: https://doi.org/10.1371/journal.pcbi.1006177.g008