Skip to main content
Advertisement

< Back to Article

Elucidation of molecular kinetic schemes from macroscopic traces using system identification

Fig 3

Classifier Module implementation.

Classifier Module flow chart implementation of the comparison between G(s), the transfer function obtained by the Identifier Module, and the transfer functions associated with the canonical configurations. This module tests sequentially whether G(s) incorporates the features of a transfer function describing a higher-order system, a first-order system, or a second-order system in each of the canonical configurations: cascade, feedback or parallel. The cost function values for the parallel and feedback optimization problems, fvalp and fvalf respectively, are used to discern between these two canonical configurations as explained in the Results section.

Fig 3

doi: https://doi.org/10.1371/journal.pcbi.1005376.g003