Abstract
Background
Telehealth could enhance rehabilitation for people with chronic health conditions. This review examined the psychometric properties of performance-based measures of physical function administered via telehealth among people with chronic health conditions using the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) approach.
Methods
This systematic review was registered with Prospero (Registration number: CRD42021262547). Four electronic databases were searched up to June 2022. Study quality was evaluated by two independent reviewers using the COSMIN risk of bias checklist. Measurement properties were rated by two independent reviewers in accordance with COSMIN guidance. Results were summarised according to the COSMIN approach and the modified GRADE approach was used to grade quality of the summarised evidence.
Results
Five articles met the eligibility criteria. These included patients with Parkinson’s Disease (n = 2), stroke (n = 1), cystic fibrosis (n = 1) and chronic heart failure (n = 1). Fifteen performance-based measures of physical function administered via videoconferencing were investigated, spanning measures of functional balance (n = 7), other measures of general functional capacity (n = 4), exercise capacity (n = 2), and functional strength (n = 2). Studies were conducted in Australia (n = 4) and the United States (n = 1). Reliability was reported for twelve measures, with all twelve demonstrating sufficient inter-rater and intra-rater reliability. Criterion validity for all fifteen measures was reported, with eight demonstrating sufficient validity and the remaining seven demonstrating indeterminate validity. No studies reported data on measurement error or responsiveness.
Conclusions
Several performance-based measures of physical function across the domains of exercise capacity, strength, balance and general functional capacity may have sufficient reliability and criterion validity when administered via telehealth. However, the evidence is of low-very low quality, reflecting the small number of studies conducted and the small sample sizes included in the studies. Future research is needed to explore the measurement error, responsiveness, interpretability and feasibility of these measures administered via telehealth.
Citation: Barry Walsh C, Cahalan R, Hinman RS, O’ Sullivan K (2022) Psychometric properties of performance-based measures of physical function administered via telehealth among people with chronic conditions: A systematic review. PLoS ONE 17(9): e0274349. https://doi.org/10.1371/journal.pone.0274349
Editor: Fatih Özden, Mugla Sitki Kocman Universitesi, TURKEY
Received: May 16, 2022; Accepted: August 25, 2022; Published: September 9, 2022
Copyright: © 2022 Barry Walsh et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the manuscript and its Supporting Information files.
Funding: One author (CBW) is supported by a research studentship from The Faculty of Education and Health Sciences, University of Limerick, Ireland. RSH is supported by a National Health & Medical Research Council Senior Research Fellowship (#1154217).
Competing interests: The authors have declared that no competing interests exist.
Introduction
Chronic health conditions have the potential to lead to significant levels of disability, mortality and reduced quality of life [1]. In 2019, on average, more than one-third of adults aged 16 and above in 26 OECD (Organisation for Economic Co-operation and Development) countries reported living with a chronic health condition [2]. The ageing nature of the Western world and the increasing prevalence of chronic conditions presents a significant socioeconomic burden and will continue to persistently challenge health care services [3, 4]. Rehabilitation has been identified as an integral aspect of chronic condition management, in order to facilitate people living with chronic health problems to independently manage their condition and improve their physical function and quality of life [5–8].
Although in-person rehabilitation is considered the default service delivery method, healthcare services lack the capacity required to meet the increasing demand for these programmes. Also, uptake levels among patients have traditionally been poor due to different barriers, such as travel and time limitations [9, 10]. Offering rehabilitation via digital platforms (telerehabilitation) may increase service accessibility and overcome barriers to traditional face-to-face programmes. Furthermore, telerehabilitation is as clinically effective as face-to-face rehabilitation for several different chronic populations [11–13]. The recent COVID-19 pandemic presented challenges for rehabilitation service providers, resulting in a dramatic increase in the use of telehealth. This accelerated shift towards the use of an alternative method of service delivery allowed health care services to maintain service accessibility and ensure continuity of patient care. Despite the evidence supporting its efficacy, resistance to the adoption of telehealth has been demonstrated by both patients and healthcare providers [14].
One of the challenges which has limited the adoption of telehealth is the perceived difficulty of assessing patients remotely, particularly the administration of performance-based measures via telehealth platforms and the uncertainty regarding the accuracy and reliability of these measures [15–17]. The use of standardised performance-based measures in clinical assessment is an important element of evidence-based rehabilitation and clinical practice [18, 19] to inform diagnosis, clinical decision making, intervention planning and goal setting [15, 20]. The regular measurement of parameters of performance-based physical function during rehabilitation programmes therefore facilitates objective monitoring and evaluation of the effectiveness of the intervention.
The reliability and validity of measures administered via telehealth has been explored in recent systematic, scoping and rapid reviews in musculoskeletal [15, 21], as well as chronic cardiac and respiratory [22, 23] populations. Zischke et al. [24] also conducted a review examining various clinical assessments conducted via telehealth. Overall, these reviews supported the feasibility of assessment via telehealth, and highlighted the reliability and validity of several performance-based measures across domains such as range of motion, strength, endurance, aerobic capacity, balance, gait and functional assessments.
However, the existing evidence exploring performance-based measures is limited, with a tendency to focus on the use of measures in specific patient cohorts, rather than considering all domains across all populations with chronic conditions. Furthermore, some of the existing reviews included patient-reported outcomes such as pain intensity, or pain response during special orthopaedic tests. While evidence demonstrates that electronic patient-reported measures are equivalent to paper-based self-reported measures when administered in various chronic populations [25–28], there is limited evidence exploring the psychometric properties and equivalence of performance-based measures administered via telehealth when compared to face-to-face administration.
Therefore, a comprehensive overview of a wide range of performance-based measures relevant to a variety of chronic neurological, respiratory and musculoskeletal conditions administered via telehealth is required. To our knowledge, this is the first review using the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) approach to evaluate the reliability and validity of performance-based measures of physical function across a broad range of chronic health conditions.
Methods
This systematic review protocol was registered with Prospero (Registration number: CRD42021262547). This review was conducted in accordance with COSMIN methodology which is a robust approach that aims to improve the selection of measurement instruments using transparent methodology.
Search strategy
A comprehensive search strategy was developed, reviewed and refined by the authors, with the assistance of a health librarian, in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines [29] (S1 Fig). An electronic database search of PubMed, EMBASE, CINAHL and PsycINFO via EBSCOhost was conducted on the 28th of June 2022. Key search terms were developed using four individual search filters. These filters included:
- Population: chronic conditions OR chronic disease OR chronic health OR chronic illness OR long term illness OR long term disability OR long term condition
- Construct: physical function OR physical performance OR functional capacity OR physical capacity
- Measurement Instrument: assessment OR evaluation OR outcome OR measure OR test
- Context: telehealth OR telerehabilitation OR telemedicine OR e-health
These individual filters were combined with the COSMIN search filter for measurement properties [30] to create the search strategy outlined in S2 Fig. Hand-searching of the reference lists of the included articles was also performed to identify additional relevant articles.
Eligibility criteria
Studies were included in the review if they met the following criteria:
- Population: adults (≥18 years) diagnosed with any chronic health condition, as defined by the ICD-10-CM [31] as a condition that lasts greater than 12 months and results in the need for ongoing medical intervention and limits self-care, independent living and social interaction. Studies including a mixed sample of acute and chronic populations were included if at least 80% of the sample had a chronic diagnosis.
- Construct: the evaluated measure was a performance-based measure of physical function, as defined by the World Health Organisation (WHO) [32] International Classification of Functioning, Disability and Health (ICF) framework as activities which relate to the ability to move around and perform daily activities e.g. strength, balance, etc.
- Measurement instrument: an established performance-based measure of physical function, commonly used in clinical practice, which was evaluated synchronously by a tester as the activity was being performed by the individual. This usually involved evaluation by timing, counting or distance methods [33].
- Setting: the evaluated measure was administered by a tester located remotely from the patient using any telehealth platform, as defined by WHO as “the delivery of health care services, where patients and providers are separated by distance. Telehealth uses information and communication technologies (ICT) for the exchange of information for the diagnosis and treatment of diseases and injuries.”.
- Measurement properties: In our pre-registered protocol, we highlighted studies must have reported one or more of the psychometric measurement properties from the COSMIN taxonomy [30]. For studies examining the validity of the measurement instrument administered via telehealth, the comparator was a face-to-face administration of the same measurement instrument. Since the comparator was always face-to-face administration of the same measure, when extracting data from the selected studies the measurement properties of interest were reliability, measurement error and criterion validity. Therefore, the remaining measurement properties outline in the COSMIN taxonomy including other forms of validity and interpretability were not considered to be outcomes of interest in this review.
Studies were excluded if (1) the evaluated measure was a self-reported measure of physical function, or a laboratory value (e.g., VO2 max, spirometry, etc.) indirectly used to assess physical function, or a self-administered measure that did not involve administration and evaluation by an independent tester; or (2) the study population consisted of post-operative patients since post-operative pain and disability levels differ in magnitude and stability from chronic conditions.
A sample of 30% of abstracts from the database search were initially screened by two independent reviewers (CBW & RC) to determine potential eligibility. As good agreement (>80%) was achieved, the remaining abstracts were screened by one reviewer (CBW). Thereafter, a sample of 30% of full texts of potentially eligible studies were reviewed to determine eligibility by two independent reviewers (CBW & RC). Any disagreements were resolved through discussion with a third reviewer (KOS). As above, good agreement was achieved, and the remaining studies were reviewed by one reviewer (CBW).
Data extraction
Data were extracted by two independent authors (CBW & KOS) using a table created by the authors following COSMIN guidance [34]. Firstly, the characteristics of the included studies and the performance-based measures evaluated within the studies were extracted. Thereafter, data relating to the evaluation of the methodological quality of the included studies and the evaluation of the measurement properties (i.e. strength of correlations/associations) were also extracted. The included performance-based measures were categorised according to the domain of physical function that they measured. These domains included exercise capacity, functional strength, functional balance and general functional capacity.
Methodological quality of included studies
The methodological quality of each of the included studies was evaluated by two independent authors (CBW & KOS) using the COSMIN risk of bias checklist and scores were determined by consensus [34]. This tool contains separate standards for each measurement property (i.e., reliability, measurement error and criterion validity) that can be used to determine the trustworthiness of the result. Each of the standards were rated and the ‘worst-score-counts’ method was applied to determine the overall quality of each measurement property reported in the included studies [34].
Evaluation of the measurement properties reported in the included studies
The COSMIN methodology was used to evaluate the measurement property results reported in each of the included studies [34]. These results were evaluated according to the criteria for good measurement properties (strength of correlations/associations with the reference standard face-to-face administration of the measure) to give a rating of sufficient (+), indeterminate (?) or insufficient (-) for each measurement property, as described by Prinsen et al. [34] (See S1 Table).
For the reliability domain, inter-rater and intra-rater reliability were evaluated by comparing the scores for the measure when administered via telehealth between different raters and also when administered by the same rater at two different time points. As recommended, a threshold of 0.70 on the intraclass correlation (ICC) or weighted kappa was used to evaluate the reliability of the measure administered via telehealth [34]. If the correlation was ≥ 0.70 the reliability received a sufficient rating. If the ICC or weighted kappa was not reported it received an indeterminate rating for reliability. The reliability of the measure was rated as insufficient if the ICC or weighted kappa score was < 0.70.
For the criterion validity domain, the measure administered via telehealth was compared to the same measure administered in a face-to-face environment. A correlation of 0.70 with the reference standard [34], which for the purpose of this review was the measure administered in a face-to-face environment, was the threshold. The validity of the measure was rated as sufficient if the correlation was ≥ 0.70. The validity was rated as indeterminate if correlations were not reported. The validity was rated as insufficient if the correlation with the reference standard was < 0.70.
Data synthesis and analysis
To synthesise the results, the evidence was summarised per measurement property (e.g., reliability, validity) per outcome measure to come to an overall conclusion regarding the reliability and validity of the measures. If multiple studies examined the same measure, the results of the studies were synthesised to achieve an overall result. In the case of inconsistency in the results between studies (e.g., both sufficient and insufficient results were found), explanations for the inconsistency were explored. When inconsistent results likely existed due to varying study quality as previously described, the results of lower quality studies were omitted and only the higher quality results were used to determine the overall rating and the quality of summarised evidence was downgraded due to inconsistency. If no logical explanation was found which could explain the inconsistency, the results were considered inconsistent. The modified GRADE approach was used by two independent reviewers and disagreements were resolved by consensus to summarise how confident we can be that the summarised evidence is trustworthy [35]. The summarised evidence was graded as high, moderate, low or very low based on the following four criteria: 1. Risk of Bias (quality of the studies); 2. Inconsistency (of the results of the studies); 3. Imprecision (total sample size of the studies) and 4. Indirectness (evidence from different populations than the population of interest). Detailed instructions on the use of the modified GRADE approach to grade the quality of the summarised evidence can be found in S2 Table. The starting point assumed that the summarised result was of high quality and was downgraded by one, two or three levels depending on the risk of bias. The summarised result was further downgraded depending on the inconsistency, imprecision and indirectness associated with the summarised result as appropriate.
When inconsistency existed between the results of the included studies examining the same measurement instrument, the results were summarised as sufficient or insufficient and the quality of the evidence was downgraded for inconsistency with one or two levels depending on the severity of the inconsistency. As the severity of inconsistency between results is context dependent, the level of severity was discussed and decided by the review team in each situation.
For imprecision, the evidence was downgraded one level if the sample size was 50–100 individuals. If the sample size was less than 50 individuals the evidence was downgraded two levels.
As this review included studies in which the >80% of the population had a chronic diagnosis, the risk of bias associate with indirectness did not exist and therefore the evidence was not downgraded for indirectness.
Results
The initial search yielded 9,906 articles, of which 7,377 remained after duplicates were removed. Five articles met the inclusion criteria and were deemed eligible for inclusion in the review. Fig 1 outlines the search results and screening process using a PRISMA flow diagram [29].
Study characteristics
A summary of the descriptive characteristics of each included study and the included performance-based measures is presented in Table 1. Four of the included studies were conducted in Australia [36–39], with the remaining study conducted in the United States [40]. A total of 77 individuals were included in the review with sample sizes ranging from 10–26 participants. Two studies included patients with Parkinson’s Disease [38, 39] and the remaining three studies included patient cohorts with stroke, cystic fibrosis and heart failure respectively [36, 37, 40].
Measurement properties of 15 performance-based physical function measures were investigated in the included studies. Inter-rater and intra-rater reliability were reported for 12 of the measures, while the criterion validity of all 15 measures was reported. No studies reported data on measurement error or responsiveness.
Of the 15 performance-based measures, seven assessed balance (Timed Up and Go Test, functional and lateral reach tests, Berg Balance Scale, step test, steps in 360 degree turn, and timed stance test) [36, 39, 40], two assessed exercise capacity (3 minute step test and 6 minute walk test) [36, 37] and two assessed functional strength (grip and pinch strength) [36, 38]. The remaining four measures assessed diverse aspects of functional capacity including the Functional Independence Measure (FIM) [38], of which only the motor components were assessed (bathing, dressing, toileting, walking, stairs, eating, grooming, bladder management, toilet transfers, bowel management bed/chair transfers, tub/shower transfers), the Unified Parkinson’s Disease Rating Scale (UPDRS) [38], of which relevant items were assessed (posture, gait, sensory complaints, falling, freezing when walking, tremor, tremor at rest, salivation, facial expression, bradykinesia, speech, action or postural hand tremor, handwriting), the Nine Hole Peg Test (38) and the European Stroke Scale [40].
Methodological quality of included studies
The COSMIN risk of bias scores for the measurement properties of the measures in each included study are displayed in Table 2. Of the studies that reported the reliability of the included measures, ten measures demonstrated adequate quality while three demonstrated inadequate quality. Of the studies that reported criterion validity of the measures, eight measures demonstrated very good quality and ten demonstrated inadequate quality. Many of the studies reporting the criterion validity of the included measures received an inadequate quality rating as per COSMIN guidance as the correlation with the reference standard was not calculated [41] (e.g. mean differences between measures administered via telehealth compared to face to face administration were reported as opposed to correlations).
Overall rating and quality of evidence
A summary of the overall rating and quality of evidence per measurement property of the included measures is presented in Table 3. These scores were developed from the information displayed in Table 2 which included the rating and the COSMIN risk of bias score. Twelve measures received ‘sufficient’ overall ratings for reliability, with a ‘very low’ quality of evidence score. Eight measures received ‘sufficient’ overall ratings and seven received ‘indeterminate’ ratings for criterion validity and were all scored as ‘low’ or ‘very low’ quality of evidence. For example, the Six Minute Walk Test (6MWT) demonstrated sufficient reliability (ICC>0.70) with a ‘very low’ quality of evidence score due to the inadequate COSMIN risk of bias rating of the included study and the small sample size (n<50). The 6MWT also demonstrated ‘sufficient’ validity (correlation with face-to-face>0.70) with a ‘low’ quality of evidence score due to the ‘very good’ COSMIN risk of bias rating of the included study and the low sample size (n<50). The 3-minute step test demonstrated ‘indeterminate’ validity as no correlation with the reference standard (face-to-face administration) was reported, which was insufficient information reported to provide a ‘sufficient’ rating according to the COSMIN guidance. The summary scores for the validity of the Timed Up and Go Test (TUGT) and grip strength reflect adjustments that were made to allow for inconsistencies in the results reported in the included studies. For example, the validity of the TUGT was reported in two studies and received an overall ‘sufficient’ validity rating (correlation>0.70) [36], with ‘very low’ quality of evidence due to the inadequate COSMIN risk of bias score of the included studies, the small sample size (<50), and the inconsistency between the validity findings of the included studies [36–39].
Exercise capacity measures
Measures of exercise capacity included in this review were the 6MWT and three minute step test. The 6MWT demonstrated sufficient reliability and criterion validity when administered via telehealth. Evidence for the administration of three minute step test via telehealth is yet to be determined as there was no information available examining its reliability, and the evidence for criterion validity was indeterminate due to non-optimal analysis. Therefore recommendation for the use of this instrument via telehealth cannot be made. However, the mean differences between the telehealth assessment and the face-to-face assessment observed by Cox et al. [37] were very small and suggest that there was no significant difference between the telehealth assessment and face-to-face administration. Therefore these three minute step test results are encouraging.
Functional balance measures
Seven measures of functional balance were included in the review. Measures with the most robust results demonstrating sufficient reliability and criterion validity were the Berg Balance Scale, TUGT, Step test and the Steps in 360 degree turn test. The other measures (Functional Reach Test, Lateral Reach Test and Timed Stance Test) all demonstrated sufficient reliability, however, the criterion validity of these measures administered via telehealth when compared to face-to-face administration could not be determined due to non-optimal analysis. The mean difference between the telehealth and face-to-face administration of the functional reach test of -1.01 as observed by Russell et al. [39] lies within the limits of agreement of -2.71 to 0.69. This is also within the clinically acceptable limit of 4.74cm [42], supporting telehealth administration of the functional reach test [43]. Similarly, the mean difference observed between the telehealth and face-to-face administration of the lateral reach test [39] of -0.79 is within the reported limits of agreement (-2.09 to 0.51) and clinically acceptable limit (4.74cm) [42], which supports this measure being administered via telehealth. Finally, the mean difference of 0.44 [39] between the timed stance tests when administered via telehealth compared to face-to-face administration is also within the limits of agreement (-4.17 to 5.06), and is less than the clinically acceptable limit (8.00 seconds). Therefore it can be reasonably assumed that the telehealth administration of the timed stance test is valid when compared to face-to-face administration.
Functional capacity measures
Other measures included in the review which measured various aspects of general functional capacity included the European Stroke Scale, Unified Parkinson’s Disease Rating Scale, Functional Independence Measure and Nine Hole Peg Test. The most robust results were reported for the Functional Independence Measure and the Unified Parkinson’s Disease Rating Scale which both demonstrated sufficient reliability and criterion validity. However, as the Unified Parkinson’s Disease Rating Scale is a population-specific measure, the Functional Independence Measure may be more appropriate for various chronic populations. While the Nine Hole Peg Test demonstrated sufficient reliability, the criterion validity was indeterminate due to non-optimal analysis. However, the mean differences of 0.25 seconds (right hand) and 0.14 seconds (left hand) observed between telehealth administration and face-to-face administration of the measure were both within the limits of agreement of -2.02 to 1.52 (right hand) and -1.34 to 1.05 (left hand), which is encouraging. Evidence for the reliability and criterion validity of the European Stroke Scale administered via telehealth is yet to be determined due to the lack of information available and non-optimal analysis.
Discussion
This systematic review identified five studies which examined the psychometric properties of fifteen performance-based measures of physical function administered via telehealth among people with various chronic conditions. Overall, there is low-very low evidence demonstrating sufficient reliability and criterion validity for a range of measures across each domain of exercise capacity, strength, balance and functional capacity when administered via telehealth and compared to face-to-face administration. The overall quality of evidence was low-very low, reflecting the small number of studies, the small sample sizes of the included studies and non-optimal analyses (i.e. failure to correlate scores with the reference standard face-to-face administration method) as per the COSMIN risk of bias tool.
The findings of sufficient reliability and criterion validity when administered via telehealth mirror that reported when many measures are administered among chronic populations in a face-to-face environment, including the 6MWT [44, 45] and the grip strength test [46, 47], as well as the Berg Balance Scale, TUGT and Step Test [48–52].
As per COSMIN guidance, in order to demonstrate ‘sufficient’ validity the measure administered via telehealth must demonstrate >0.70 correlation with the measurement when administered in a face-to-face setting. While the included measures which appeared to be valid when compared to face-to-face administration, the correlations were not calculated and therefore there was not sufficient information to classify the criterion validity as ‘sufficient’ as per the COSMIN standards. Also, the quality of the included studies were downgraded for this same reason. Therefore these findings should be interpreted with caution.
Although the included studies did not report on all measurement properties for each measure, sufficient evidence was reported for the reliability and criterion validity of some measures across several domains. No evidence regarding the measurement error or responsiveness of the included measures was reported in the included studies.
Strengths and limitations
Strengths of this review include the prospective protocol registration, following PRISMA guidance, as well as using two reviewers for screening, shortlisting and data extraction. A particular strength is using the COSMIN approach, which had not been used in previous psychometric evaluations for performance measures via telehealth.
There were also some limitations to be acknowledged. As previously stated, two independent reviewers screened a sample of 30% of abstracts and relevant full texts to determine eligibility. As good agreement was achieved on the 30% sample, the remaining screening process was not performed in duplicate. Although the quality of the summarised evidence was rated using the modified GRADE approach by two independent reviewers, neither of these reviewers were formally trained in the use of this method. Due to the heterogeneous nature of the included measures and the populations of the included studies, a meta-analysis could not be performed and the results could not be quantitatively summarised. As the majority of the results could not be combined, best evidence synthesis was mostly obtained from a single study. Further evidence may have been identified from studies of post-operative populations, such as individuals post total knee arthroplasty [53]. However, these were excluded as pain and disability levels immediately post-operatively, and how much these change relatively quickly, are quite different from other chronic conditions where physical function may be more stable over time. There was limited information reported regarding the characteristics of the samples in the included studies in relation to aspects such as socioeconomic status, cognitive status and technological literacy. Also, the included studies were all carried out in countries with ‘very high’ Human Development Index scores [54]. These factors could potentially impact the external validity of the findings. Although Cox et al. [37] reported the usability of the three minute step test administered via telehealth and Hwang et al. [36] reported some information regarding the number and nature of technical issues encountered during telehealth administration of the 6MWT, TUGT and grip and pinch strength, there was limited information reported in the included studies regarding the interpretability and feasibility of the included measures when administered via telehealth. As noted in the eligibility criteria, this review was concerned with examining the validity of measures administered via telehealth when compared to face-to-face administration of the same measure. Therefore, other types of validity, such as content and construct validity, were not reported in this review. Due to the eligibility criteria and aims of this review, the outcomes of interest were reliability, measurement error and criterion validity. For this reason, we followed COSMIN recommendations for evaluating reliability, measurement error and criterion validity but a priori did not choose to evaluate other types of validity, internal structure, interpretability and feasibility.
Clinical implications
Encouragingly, several performance-based measures of physical function across different domains (e.g. exercise capacity, strength and balance) may have satisfactory reliability and criterion validity when used in a telehealth environment. Furthermore, the psychometric properties of these measures appears similar to that reported for the same measures when used in a face-face context. This should reassure clinicians that using performance-based measures of physical function via telehealth is possible. However, this evidence is of low-very low quality and there is a significant lack of information regarding the measurement error and responsiveness of these measures. Furthermore, information regarding the interpretability and feasibility of the included measures was very limited [36, 37].
Future research
This systematic review highlights the need for further larger, high quality research, in line with COSMIN guidance, exploring the psychometric properties of performance-based measures of physical function administered via telehealth among people with various chronic conditions. In particular more studies examining the measurement error, responsiveness, interpretability and feasibility of these instruments are required. Although some of the measures included in this review demonstrated sufficient reliability and validity, none of the measures were evaluated with respect to all measurement properties and therefore strong recommendations cannot yet be made. Additionally, the lack of studies exploring the administration of performance-based measures of physical function via telehealth among chronic musculoskeletal populations is acknowledged. Therefore this review highlights the need for future studies to be conducted in this population.
Conclusion
A wide range of performance-based measures measuring various domains of physical function administered via telehealth among chronic populations have been identified in this review. All of these measures appear to be reliable when used in a telehealth environment. Validity of these measures is less certain, and there is no information regarding the measurement error or responsiveness of these measures. Further high quality research is required to examine the psychometric properties of a core set of measures administered via telehealth among people with chronic health conditions, particularly regarding measurement error, responsiveness, feasibility and interpretability.
Supporting information
S1 Fig. Preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines.
https://doi.org/10.1371/journal.pone.0274349.s001
(PDF)
S1 Table. Criteria for good measurement properties.
https://doi.org/10.1371/journal.pone.0274349.s003
(PDF)
S2 Table. Instructions on the use of the modified GRADE approach.
https://doi.org/10.1371/journal.pone.0274349.s004
(PDF)
Acknowledgments
We acknowledge the support of Liz Dore, Faculty of Education and Health Sciences librarian at the Glucksman Library in the University of Limerick, for her assistance with the development of the search strategy.
References
- 1.
Darker C, Whiston L, O’Shea B. Chronic disease management in Ireland: Perspectives from patients and clinical stakeholders–Implications and recommendations for the Irish healthcare system. Dublin, Trinity College. 2015.
- 2.
OECD. Health at a glance 2021: OECD indicators. OECD Publishing, Paris; 2021.
- 3. Balanda K, Barron S, Fahy L, McLaughlin A. Making Chronic Conditions Count: Hypertension, Stroke, Coronary Heart Disease, Diabetes. A systematic approach to estimating and forecasting population prevalence on the island of Ireland. 2010.
- 4. Hernández B, Reilly RB, Kenny RA. Investigation of multimorbidity and prevalent disease combinations in older Irish adults using network analysis and association rules. Scientific reports. 2019;9(1):1–12.
- 5. Bolton CE, Bevan-Smith EF, Blakey JD, Crowe P, Elkin SL, Garrod R, et al. British Thoracic Society guideline on pulmonary rehabilitation in adults: accredited by NICE. Thorax. 2013;68(Suppl 2):ii1–ii30.
- 6.
NICE. Osteoarthritis: care and management in adults: National Institute for Health and Clinical Excellence (NICE); 2014.
- 7. Stucki G, Bickenbach J, Gutenbrunner C, Melvin JL. Rehabilitation: The health strategy of the 21st century. 2018.
- 8. Long L, Mordi IR, Bridges C, Sagar VA, Davies EJ, Coats AJ, et al. Exercise‐based cardiac rehabilitation for adults with heart failure. Cochrane Database of Systematic Reviews. 2019(1). pmid:30695817
- 9. Desveaux L, Goldstein R, Mathur S, Brooks D. Barriers to physical activity following rehabilitation: Perspectives of older adults with chronic disease. Journal of aging and physical activity. 2016;24(2):223–33. pmid:26372671
- 10. Oates GR, Niranjan SJ, Ott C, Scarinci I, Schumann C, Parekh T, et al. Adherence to pulmonary rehabilitation in COPD: a qualitative exploration of patient perspectives on barriers and facilitators. Journal of cardiopulmonary rehabilitation and prevention. 2019;39(5):344. pmid:31348127
- 11. Bourne S, DeVos R, North M, Chauhan A, Green B, Brown T, et al. Online versus face-to-face pulmonary rehabilitation for patients with chronic obstructive pulmonary disease: randomised controlled trial. BMJ open. 2017;7(7):e014580. pmid:28716786
- 12. Cottrell MA, Galea OA, O’Leary SP, Hill AJ, Russell TG. Real-time telerehabilitation for the treatment of musculoskeletal conditions is effective and comparable to standard practice: a systematic review and meta-analysis. Clinical rehabilitation. 2017;31(5):625–38. pmid:27141087
- 13. Jiang S, Xiang J, Gao X, Guo K, Liu B. The comparison of telerehabilitation and face-to-face rehabilitation after total knee arthroplasty: A systematic review and meta-analysis. Journal of Telemedicine and Telecare. 2018;24(4):257–62. pmid:28027679
- 14. Kruse CS, Krowski N, Rodriguez B, Tran L, Vela J, Brooks M. Telehealth and patient satisfaction: a systematic review and narrative analysis. BMJ open. 2017;7(8):e016242. pmid:28775188
- 15. Mani S, Sharma S, Omar B, Paungmali A, Joseph L. Validity and reliability of Internet-based physiotherapy assessment for musculoskeletal disorders: a systematic review. Journal of telemedicine and telecare. 2017;23(3):379–91. pmid:27036879
- 16. Bennell KL, Lawford BJ, Metcalf B, Mackenzie D, Russell T, van den Berg M, et al. Physiotherapists and patients report positive experiences overall with telehealth during the COVID-19 pandemic: a mixed-methods study. Journal of physiotherapy. 2021;67(3):201–9. pmid:34147399
- 17. Malliaras P, Merolli M, Williams C, Caneiro J, Haines T, Barton C. ‘It’s not hands-on therapy, so it’s very limited’: telehealth use and views among allied health clinicians during the coronavirus pandemic. Musculoskeletal Science and Practice. 2021;52:102340. pmid:33571900
- 18. Van Peppen RP, Hendriks H, Van Meeteren NL, Helders PJ, Kwakkel G. The development of a clinical practice stroke guideline for physiotherapists in The Netherlands: a systematic review of available evidence. Disability and rehabilitation. 2007;29(10):767–83. pmid:17457735
- 19. Sullivan JE, Crowner BE, Kluding PM, Nichols D, Rose DK, Yoshida R, et al. Outcome measures for individuals with stroke: process and recommendations from the American Physical Therapy Association neurology section task force. Physical therapy. 2013;93(10):1383–96. pmid:23704035
- 20. Russell T. Goniometry via the internet. Australian Journal of Physiotherapy. 2007;53(2):136–. pmid:17535154
- 21. Grona SL, Bath B, Busch A, Rotter T, Trask C, Harrison E. Use of videoconferencing for physical therapy in people with musculoskeletal conditions: a systematic review. Journal of telemedicine and telecare. 2018;24(5):341–55. pmid:28403669
- 22. Holland AE, Malaguti C, Hoffman M, Lahham A, Burge AT, Dowman L, et al. Home-based or remote exercise testing in chronic respiratory disease, during the COVID-19 pandemic and beyond: a rapid review. Chronic respiratory disease. 2020;17:1479973120952418. pmid:32840385
- 23. Houchen-Wolloff L, Daynes E, Watt A, Chaplin E, Gardiner N, Singh S. Which functional outcome measures can we use as a surrogate for exercise capacity during remote cardiopulmonary rehabilitation assessments? A rapid narrative review. ERJ Open Research. 2020;6(4). pmid:33313302
- 24. Zischke C, Simas V, Hing W, Milne N, Spittle A, Pope R. The utility of physiotherapy assessments delivered by telehealth: A systematic review. Journal of global health. 2021;11. pmid:34956637
- 25. Gwaltney CJ, Shields AL, Shiffman S. Equivalence of electronic and paper-and-pencil administration of patient-reported outcome measures: a meta-analytic review. Value in health. 2008;11(2):322–33. pmid:18380645
- 26. Campbell N, Ali F, Finlay AY, Salek SS. Equivalence of electronic and paper-based patient-reported outcome measures. Quality of Life Research. 2015;24(8):1949–61. pmid:25702266
- 27. Aiyegbusi OL, Nair D, Peipert JD, Schick-Makaroff K, Mucsi I. A narrative review of current evidence supporting the implementation of electronic patient-reported outcome measures in the management of chronic diseases. Therapeutic advances in chronic disease. 2021;12:20406223211015958. pmid:34104376
- 28. Muehlhausen W, Doll H, Quadri N, Fordham B, O’Donohoe P, Dogar N, et al. Equivalence of electronic and paper administration of patient-reported outcome measures: a systematic review and meta-analysis of studies conducted between 2007 and 2013. Health and quality of life outcomes. 2015;13(1):1–20.
- 29. Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. International Journal of Surgery. 2021;88:105906. pmid:33789826
- 30. Mokkink LB, Terwee CB, Patrick DL, Alonso J, Stratford PW, Knol DL, et al. The COSMIN checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments: an international Delphi study. Quality of life research. 2010;19(4):539–49. pmid:20169472
- 31.
World Health Organisation. The ICD-10 Classification of Mental and Behavioural Disorders: Diagnostic Criteria for Research, Geneva, Switzerland. World Health Organization. 1993.
- 32.
World Health Organisation. International classification of functioning, disability and health: ICF. World Health Organization. 2001.
- 33. Kroman SL, Roos EM, Bennell KL, Hinman RS, Dobson F. Measurement properties of performance-based outcome measures to assess physical function in young and middle-aged people known to be at high risk of hip and/or knee osteoarthritis: a systematic review. Osteoarthritis and cartilage. 2014;22(1):26–39. pmid:24216060
- 34. Mokkink LB, Boers M, Van Der Vleuten C, Bouter LM, Alonso J, Patrick DL, et al. COSMIN Risk of Bias tool to assess the quality of studies on reliability or measurement error of outcome measurement instruments: a Delphi study. BMC medical research methodology. 2020;20(293). pmid:33267819
- 35. Prinsen CA, Mokkink LB, Bouter LM, Alonso J, Patrick DL, De Vet HC, et al. COSMIN guideline for systematic reviews of patient-reported outcome measures. Quality of Life Research. 2018;27(5):1147–57. pmid:29435801
- 36. Hwang R, Mandrusiak A, Morris NR, Peters R, Korczyk D, Russell T. Assessing functional exercise capacity using telehealth: Is it valid and reliable in patients with chronic heart failure? Journal of Telemedicine and Telecare. 2017;23(2):225–32. pmid:26915366
- 37. Cox NS, Alison JA, Button BM, Wilson JW, Holland AE. Assessing exercise capacity using telehealth: a feasibility study in adults with cystic fibrosis. Respiratory Care. 2013;58(2):286–90. pmid:22711058
- 38. Hoffmann T, Russell T, Thompson L, Vincent A, Nelson M. Using the Internet to assess activities of daily living and hand function in people with Parkinson’s disease. NeuroRehabilitation. 2008;23(3):253–61. pmid:18560142
- 39. Russell T, Hoffmann T, Nelson M, Thompson L, Vincent A. Internet-based physical assessment of people with Parkinson disease is accurate and reliable: A pilot study. Journal of rehabilitation research and development. 2013;50(5):643. pmid:24013912
- 40. Palsbo SE, Dawson SJ, Savard L, Goldstein M, Heuser A. Televideo assessment using Functional Reach Test and European Stroke Scale. Journal of Rehabilitation Research & Development. 2007;44(5). pmid:17943677
- 41. Mokkink LB, De Vet HC, Prinsen CA, Patrick DL, Alonso J, Bouter LM, et al. COSMIN risk of bias checklist for systematic reviews of patient-reported outcome measures. Quality of Life Research. 2018;27(5):1171–9. pmid:29260445
- 42. Smith PS, Hembree JA, Thompson ME. Berg Balance Scale and Functional Reach: determining the best clinical tool for individuals post acute stroke. Clinical rehabilitation. 2004;18(7):811–8. pmid:15573838
- 43. Bland JM, Altman DG. Measuring agreement in method comparison studies. Statistical methods in medical research. 1999;8(2):135–60. pmid:10501650
- 44. Uszko-Lencer NH, Mesquita R, Janssen E, Werter C, Brunner-La Rocca H-P, Pitta F, et al. Reliability, construct validity and determinants of 6-minute walk test performance in patients with chronic heart failure. International journal of cardiology. 2017;240:285–90. pmid:28377186
- 45. Singh SJ, Puhan MA, Andrianopoulos V, Hernandes NA, Mitchell KE, Hill CJ, et al. An official systematic review of the European Respiratory Society/American Thoracic Society: measurement properties of field walking tests in chronic respiratory disease. European Respiratory Journal. 2014;44(6):1447–78. pmid:25359356
- 46. Bobos P, Nazari G, Lu Z, MacDermid JC. Measurement properties of the hand grip strength assessment: a systematic review with meta-analysis. Archives of physical medicine and rehabilitation. 2020;101(3):553–65. pmid:31730754
- 47. Lamers I, Kelchtermans S, Baert I, Feys P. Upper limb assessment in multiple sclerosis: a systematic review of outcome measures and their psychometric properties. Archives of physical medicine and rehabilitation. 2014;95(6):1184–200. pmid:24631802
- 48. Hill KD, Bernhardt J, McGann AM, Maltese D, Berkovits D. A new test of dynamic standing balance for stroke patients: reliability, validity and comparison with healthy elderly. Physiotherapy Canada. 1996;48(4):257–62.
- 49. Blum L, Korner-Bitensky N. Usefulness of the Berg Balance Scale in stroke rehabilitation: a systematic review. Physical therapy. 2008;88(5):559–66. pmid:18292215
- 50. Jácome C, Cruz J, Oliveira A, Marques A. Validity, reliability, and ability to identify fall status of the Berg Balance Scale, BESTest, Mini-BESTest, and Brief-BESTest in patients with COPD. Physical therapy. 2016;96(11):1807–15. pmid:27081201
- 51. Christopher A, Kraft E, Olenick H, Kiesling R, Doty A. The reliability and validity of the timed up and go as a clinical tool in individuals with and without disabilities across a lifespan: A systematic review: Psychometric properties of the timed up and go. Disability and Rehabilitation. 2021;43(13):1799–813.
- 52. Mesquita R, Wilke S, Smid DE, Janssen DJ, Franssen FM, Probst VS, et al. Measurement properties of the Timed Up & Go test in patients with COPD. Chronic respiratory disease. 2016;13(4):344–52.
- 53. Cabana F, Boissy P, Tousignant M, Moffet H, Corriveau H, Dumais R. Interrater agreement between telerehabilitation and face-to-face clinical outcome measurements for total knee arthroplasty. Telemedicine and e-Health. 2010;16(3):293–8. pmid:20406116
- 54.
World Population Review. Human Development Index (HDI) by Country 2022 2022 [Available from: https://worldpopulationreview.com].