Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Assessment of aspirin response in patients undergoing neuroendovascular treatments: A comparison of five platelet function tests across two platforms

Abstract

Aspirin is widely used for periprocedural antiplatelet therapy in neuroendovascular procedures; however, variability in patient response poses clinical challenges. This study aimed to assess five platelet function tests on two different platforms: light transmission aggregometry (LTA) using the CN-6000 device and the VerifyNow system, which were utilized to assess patients undergoing neuroendovascular procedures. A total of 124 patients who underwent elective neuroendovascular procedures and received perioperative aspirin-based antiplatelet therapy between September 2020 and December 2023 were retrospectively reviewed. Platelet function was assessed at three time points: before surgery, 1–3 days after surgery, and 1 month following the procedure. The assessments included maximum aggregation (MA) induced by 1 mM arachidonic acid (AA), 10 μM ADP, and 1 μg/mL collagen, as well as collagen-induced platelet aggregation level (CPAL) and aspirin reaction units (ARU). Significant perioperative changes were observed only with 1 mM AA MA, which increased immediately after surgery (p < 0.001) and decreased at 1 month (p = 0.013), while other tests showed no significant differences. Correlation analysis revealed the strongest association between 1 mM AA MA and 1 μg/mL collagen MA (r = 0.65), followed by CPAL (r = 0.62). ARU correlated modestly with LTA-based measures (r ≤ 0.34). Receiver operating characteristic analysis identified CPAL >6.0 and collagen MA > 43.2% as equivalent to AA MA > 20%. In this cohort, perioperative changes were detected by 1 mM AA MA but not by the other platelet function tests, and correlations between VerifyNow ARU and LTA-based measurements were modest. However, the clinical significance of these differences remains to be established. Automated LTA using CN-6000 may offer a practical option for aspirin monitoring in patients undergoing neuroendovascular procedures. Further prospective studies are warranted to validate its clinical utility.

Introduction

Aspirin is one of the most extensively used pharmacological agents. It exerts its antiplatelet effect through irreversible acetylation and inhibition of platelet cyclooxygenase-1 (COX-1). This enzyme plays a key role in the synthesis of thromboxane A2 (TXA2) from arachidonic acid (AA). TXA2 acts as a potent stimulator of platelet function and vasoconstriction [1]. Patients who are hypo-responders to aspirin are considered to show “aspirin resistance (AR),” which may result from single nucleotide polymorphisms affecting COX-1 and platelet function, inflammation, and metabolic syndrome [1–3]. AR has been associated with thrombotic events [4].

Multiple methodologies for assessing platelet function are currently available; however, no standardized consensus has been established [5–7]. Among platelet function tests, VerifyNow is the most extensively used method [8]. Nonetheless, discrepancies have been observed among various assays used to evaluate the effect [6,7]. Therefore, different strategies are employed for aspirin management in neuroendovascular interventions [6,9].

Light transmission aggregometry (LTA), developed in 1962, is an in vitro technique for assessing platelet function [10]. This method is widely applied to identify platelet function disorders, such as those linked to von Willebrand disease and thrombasthenia. According to the International Society on Thrombosis and Haemostasis Scientific and Standardization Committee, LTA is considered the reference standard for evaluating platelet function [11].

According to a questionnaire survey conducted in the neuroendovascular field, LTA is the second most widely used platelet function assay in Japan, with VerifyNow being the most commonly used [8]. The evaluation of AR by LTA has been performed using agonists such as AA, collagen, and ADP, among which assessment using AA has been the most common [4,6,12,13]. By employing the automated coagulation analysis technology developed by Sysmex, LTA can be fully automated and exhibits robust correlation with maximum aggregation (MA) measurements on existing devices [14–20]. To address the limitations of conventional LTA, the Collagen-induced Platelet Aggregation Level (CPAL) scoring system was developed [21] and subsequently tested [19,20,22] using measurements at two different concentrations.

Initial assessments of CPAL and MA were previously conducted using pseudo-abnormal samples (blood from healthy volunteers with aspirin supplementation), and comparisons between CPAL and VerifyNow were performed in a small cohort [23]. The present study aimed to evaluate and compare five platelet function assays conducted across two platforms in individuals who received neuroendovascular therapy. Specifically, the study analyzed and compared 1 mM AA MA, 10 μM ADP MA, 1 μg/mL collagen MA, CPAL measured using the CN-6000 system, and ARU obtained via VerifyNow. The main objectives of this study were to compare results obtained from the CN-6000 and VerifyNow platforms and to evaluate the relationship between measurements from these two systems over time in patients undergoing surgical procedures.

Materials and methods

Study population

This retrospective cohort study included all patients receiving periprocedural antiplatelet therapy for elective neuroendovascular treatments, including carotid stenting, coil embolization, or flow diverter placement, between September 2020 and December 2023. No further inclusion or exclusion criteria were implemented. All participants provided written informed consent. Ethical approval was granted by the ethics committees of Gifu University School of Medicine and Sysmex Corporation (approval numbers: 2019-128 and 2019-45, respectively), and the study adhered to the principles outlined in the Declaration of Helsinki. These data were accessed on June 10, 2025. The authors affiliated with Gifu University had access to information that could identify individual participants during data collection; however, all information was anonymized after data collection. Blood samples were obtained at three designated time points: before surgery, 1–3 days after surgery, and 1 month after surgery. The same 124 patients underwent all five platelet function tests before surgery, 1–3 days after surgery, and 1 month after surgery. These assessments constituted repeated measurements within the same patients during antiplatelet therapy. Platelet function testing was performed to assess platelet responsiveness during the perioperative follow-up period. Because all patients had received antiplatelet therapy for at least 1 week before surgery, the preoperative measurement represented an on-treatment assessment rather than a baseline measurement obtained before the initiation of antiplatelet therapy. Measurements obtained 1–3 days and 1 month after surgery were used to evaluate perioperative changes in platelet responsiveness during antiplatelet therapy. The 1-month evaluation corresponded to the discontinuation of dual antiplatelet therapy in patients who underwent carotid stenting, which is the procedure with the shortest dual therapy duration at Gifu University. Notably, earlier research has shown that thromboembolic complications are rare after 30 days following stent-assisted coiling or flow-diversion procedures [24].

All patients were administered antiplatelet therapy for a minimum of 1 week before surgery. At Gifu University, the typical protocol involved starting a fixed-dose combination of aspirin with either clopidogrel or prasugrel 1 week prior to the procedure. Patients who had been receiving antiplatelet agents prior to surgical planning remained on their established regimen. In cases of carotid stenting, dual antiplatelet therapy was continued for approximately 1 month after surgery, whereas for flow-diverter placement, it was maintained for approximately 6 months postoperatively. In contrast, patients treated with simple coil embolization received antiplatelet monotherapy.

Light transmission aggregometry and CPAL

This analysis was performed in accordance with the principles outlined in the literature [23]. In this study, platelet function testing was performed using the Automated Blood Coagulation Analyzer CN-6000 (Sysmex Corp., Kobe, Japan), applying the same analytical principles as those used for the CS-5100 system. The procedural steps are outlined below.

Blood samples were drawn into Insepack II-W tubes (SEKISUI MEDICAL Corp., Tokyo, Japan) containing 3.2% buffered sodium citrate at a ratio of 1:10. The tubes were gently inverted to mix and centrifuged at 150 × g for 10 minutes at room temperature to obtain platelet-rich plasma (PRP). The PRP was transferred into polypropylene tubes using plastic pipettes, sealed, and kept at ambient temperature for subsequent analysis. The initial sample tube was subsequently centrifuged at 1,500 × g for 15 minutes at room temperature to obtain platelet-poor plasma (PPP). All processing steps were completed within 4 hours of blood collection. Platelet counts in PRP were determined using the Automated Hematology Analyzer XN series XN-9100 (Sysmex Corp., Kobe, Japan).

In analyses performed using the CN-6000 system, 100% aggregation was defined as the absorbance of 140 μL PPP combined with 20 μL saline. For PRP testing, 140 μL PRP and 20 μL agonist (ratio 7:1) were dispensed into a cuvette containing a stir bar, and the instrument automatically determined the 0% aggregation baseline. Absorbance measurements were taken over a 300-second period with continuous stirring at a fixed speed of 800 rpm. Aggregation was induced using Revohem ADP (final concentration: 10 μM), Revohem Collagen (final concentrations: 1 μg/mL and 5 μg/mL), and Revohem Arachidonic Acid (final concentration: 1 mM); all reagents were obtained from Sysmex Corp., Kobe, Japan. CPAL scores were derived from waveform data generated using two collagen concentrations (1 μg/mL and 5 μg/mL) and were calculated automatically and visualized via CN-6000 software. Elevated CPAL values reflected increased platelet aggregation activity.

VerifyNow aspirin assay

The VerifyNow system (Accumetrics, San Diego, CA, USA) is a cartridge-based assay that measures platelet agglutination in whole blood in response to AA stimulation at a final concentration of 1 mM [25]. Once a citrated whole blood sample is placed into the cartridge, AA is metabolized to TXA2 via COX-1, leading to platelet activation. Activated platelets bind to fibrinogen-coated beads through GPIIb/IIIa receptors, resulting in agglutination. As these platelet–bead complexes settle, infrared light transmittance through the chamber increases. Results are expressed in aspirin reaction units (ARU). Based on existing literature, a value of 550 ARU on the VerifyNow Aspirin Assay is commonly used as the cutoff for identifying AR [6,25].

Definition of AR

Consistent with previously published studies, AR was defined as 1 mM AA MA > 20% [4,6], 10 μM ADP MA > 70% [6,13], or VerifyNow ARU > 550 [6,25]. As no universally accepted consensus exists regarding appropriate cutoff values for defining AR based on 1 µg/mL collagen MA and CPAL, cutoff values were determined by comparison with the commonly used 1 mM AA MA measured by LTA.

Statistical analysis

Statistical analysis was conducted using JMP version 19 (SAS Institute, Cary, NC, USA). Dunn’s test was applied for comparisons of continuous variables. Cutoff values for 1 μg/mL collagen MA and CPAL were determined by evaluating the area under the receiver operating characteristic (ROC) curve, using 1 mM AA MA at 20% as the reference point [4,6]. Two-by-two contingency tables were constructed to illustrate agreement between the different methods and support qualitative assessment. Spearman’s rank correlation was applied to examine associations among the various quantification techniques. Statistical significance was set at p < 0.05.

Results

Baseline clinical characteristics for the study population are presented in Table 1. The cohort comprised 124 patients, with a median age of 73 years (range: 26–92 years), and 60.5% were male. The median platelet count in PRP was 30.4 × 10⁴/μL (range: 8.9–60.9 × 10⁴/μL). Among the patients, 26 (21.0%) had a history of coronary artery disease, 3 (2.4%) had peripheral arterial disease, and 57 (46.0%) had experienced stroke. Regarding antiplatelet therapy, 83 patients (66.9%) received aspirin plus clopidogrel; 36 (29.0%) received aspirin plus prasugrel; 1 (0.8%) received aspirin plus cilostazol; 3 (2.4%) received triple therapy comprising aspirin, clopidogrel, and cilostazol; and 1 (0.8%) received aspirin, prasugrel, and cilostazol.

thumbnail
Table 1. Demographic and clinical attributes at baseline.

https://doi.org/10.1371/journal.pone.0363376.t001

Aggregate platelet function data for all five tests are presented in Table 2. The mean values were as follows: ARU, 449.3; 1 mM AA MA, 25.0%; 10 μM ADP MA, 69.8%; 1 μg/mL collagen MA, 41.0%; and CPAL, 5.8.

thumbnail
Table 2. The mean, median, and interquartile range (IQR) for platelet aggregation measurements (n = 372).

https://doi.org/10.1371/journal.pone.0363376.t002

Average values at the three assessment points (preoperatively, 1–3 days postoperatively, and 1 month after surgery) are presented in Table 3 and Fig 1. The highest median value for 1 mM AA MA was observed immediately after surgery (1–3 days). Comparative analysis across these time points revealed significant differences in 1 mM AA MA between preoperative and immediate postoperative measurements (p < 0.001) and between immediate postoperative and 1-month follow-up (p = 0.013). No significant differences were detected for ARU, 10 μM ADP MA, 1 μg/mL collagen MA, or CPAL.

thumbnail
Table 3. Platelet aggregation results from repeated measurements in the same 124 patients before surgery (A), 1–3 days after surgery (B), and 1 month after surgery (C).

https://doi.org/10.1371/journal.pone.0363376.t003

thumbnail
Fig 1. Changes in platelet aggregation before surgery, 1–3 days after, and 1 month later.

Platelet aggregation test results obtained from the same 124 patients before surgery (A), 1–3 days after surgery (B), and 1 month after surgery (C). Comparisons among A, B, and C represent within-patient longitudinal comparisons during the perioperative follow-up period. The boxes represent the median and interquartile range (IQR), and the range from the first quartile minus 1.5 × the IQR to the third quartile plus 1.5 × the IQR is indicated using the whiskers. *p < 0.05.

https://doi.org/10.1371/journal.pone.0363376.g001

A CPAL score of 6.0 and a 1 μg/mL collagen MA value of 43.2% were identified as equivalent to a 1 mM AA MA of 20%, based on ROC curve analysis [4,6]. Agreement between the five platelet aggregation parameters, stratified by analytical platform (VerifyNow vs. CN-6000), is presented in Table 4.

thumbnail
Table 4. Stratification of platelet aggregation data by cutoff values (ARU, 1 mM AA MA, 10 μM ADP MA, 1 μg/mL collagen MA, and CPAL) and measurement system (VerifyNow or CN-6000) (n = 372).

https://doi.org/10.1371/journal.pone.0363376.t004

The cutoff values for ARU (550), 1 mM AA MA (20%), and 10 μM ADP MA (70%) were sourced from existing literature [4,6,13,25], and the cutoff values for collagen MA and CPAL were determined using area under the receiver operating characteristic curve analysis.

Fig 2 illustrates the degree of concordance among platelet aggregation tests, with significant correlations observed across all five methods. The correlation coefficient for ARU, frequently used in VerifyNow, was highest with 1 mM AA MA (r = 0.34), followed by 1 μg/mL collagen MA (r = 0.27), CPAL (r = 0.24), and 10 μM ADP MA (r = 0.23). The correlation coefficient for 1 mM AA MA was highest with 1 μg/mL collagen MA (r = 0.65), followed by CPAL (r = 0.62),10 μM ADP MA (r = 0.39), and ARU (r = 0.34).

thumbnail
Fig 2. Scatter plots showing relationships among platelet aggregation tests.

The scatter plots illustrate relationships among platelet aggregation data associated with ARU, 1 mM AA MA, 10 μM ADP MA, 1 μg/mL collagen MA, and CPAL (n = 372). (Top left) The horizontal and vertical arrowed lines represent the cutoff values for 1 mM AA MA (>20%) and ARU (>550), respectively. (Top left middle) The horizontal and vertical arrowed lines represent the cutoff values for 10 μM ADP MA (>70%) and ARU (>550), respectively. (Top right middle) The horizontal and vertical arrowed lines represent the cutoff values for 1 μg/mL collagen MA (>43.2%) and ARU (>550), respectively. (Top right) The horizontal and vertical arrowed lines represent the cutoff values for CPAL (>6.0) and ARU (>550), respectively. (Center left) The horizontal and vertical arrowed lines represent the cutoff values for 10 μM ADP MA (>70%) and 1 mM AA MA (>20%), respectively. (Center middle) The horizontal and vertical arrowed lines represent the cutoff values for 1 μg/mL collagen MA (>43.2%) and 1 mM AA MA (>20%), respectively. (Center right) The horizontal and vertical arrowed lines represent the cutoff values for CPAL (>6.0) and 1 mM AA MA (>20%), respectively. (Bottom left) The horizontal and vertical arrowed lines represent the cutoff values for 1 μg/mL collagen MA (>43.2%) and 10 μM ADP MA (>70%), respectively. (Bottom middle) The horizontal and vertical arrowed lines represent the cutoff values for CPAL (>6.0) and 10 μM ADP MA (>70%), respectively. (Bottom right) The horizontal and vertical arrowed lines represent the cutoff values for CPAL (>6.0) and 1 μg/mL collagen MA (>43.2%), respectively.

https://doi.org/10.1371/journal.pone.0363376.g002

Discussion

The principal finding of this study was that the five platelet function tests exhibited distinct response patterns and were not necessarily interchangeable. Correlations between VerifyNow ARU and the LTA-based measurements were modest, whereas stronger correlations were observed among some of the LTA-based measurements. These differences may reflect the distinct analytical principles, sample types, agonists, and measurement endpoints of the assays. Therefore, results obtained using one assay should not be interpreted as directly equivalent to those obtained using another assay. Because most patients in the present cohort received concomitant P2Y12 inhibitor therapy, ADP-based aggregometric results should be interpreted with this in mind. In fact, P2Y12 inhibitor-related platelet function in neuroendovascular patients has already been investigated separately by our group using a related perioperative cohort, in which APAL, 10 μM ADP maximum aggregation, PRU, and % inhibition were compared across time points [26]. Therefore, the present study was designed to focus primarily on aspirin responsiveness, and a detailed P2Y12-focused analysis, including disaggregation analysis, was considered beyond the scope of this manuscript. A recent study of aspirin-treated patients demonstrated substantial heterogeneity in responses to other agonists among patients with low AA-induced aggregation, with collagen-induced aggregation being particularly informative for identifying residual platelet reactivity [27]. In the present study, 1 mM AA MA and 1 μg/mL collagen MA were correlated but did not show complete agreement. These findings suggest that AA- and collagen-induced aggregation may reflect different aspects of platelet responsiveness and that a low AA-induced aggregation result does not necessarily indicate uniformly reduced platelet responses to other agonists.

Overall, 62.4% of ARU measurements (232 of 372 measurements) were concentrated within the range of 370–450, whereas the corresponding LTA-based measurements showed a broader distribution. This difference in distribution may reflect differences in the analytical characteristics of the assays; however, the present study was not designed to determine whether one assay provides greater measurement resolution than another. Substantial interindividual variability was observed across platelet function measurements in the present cohort, and this variability should be considered when interpreting aspirin responsiveness in neuroendovascular patients. This inter-individual variability should be distinguished from the intra-individual longitudinal changes observed across the three measurement time points within the same patients. In addition, platelet aggregation results may be influenced by comorbidities, concomitant medications, and genetic background, independently of the testing method used, and these factors may contribute to interindividual variability in platelet responsiveness [28,29]. Such considerations may be important for the further development of personalized antiplatelet treatment strategies.

A significant perioperative change was detected by 1 mM AA MA, whereas no significant changes were detected by the other platelet function tests. This finding may reflect differences in the biological or analytical responsiveness of the assays to perioperative changes. Surgical trauma and the insertion of foreign materials, such as stents and coils, may influence platelet reactivity; however, the present study did not evaluate the mechanisms underlying the observed laboratory change or its association with clinical thrombotic outcomes. Therefore, 1 mM AA MA appeared more responsive to perioperative changes in this cohort, but the present findings do not establish its greater accuracy or clinical superiority over the other assays. Although healthy volunteers were not included in the present study, previously reported reference values for 1 mM AA MA obtained using the same analytical system and reagent concentration were substantially higher than the values observed in our cohort [30,31]. This finding provides contextual support for reduced platelet aggregation in this antiplatelet-treated population, although these external reference values should not be regarded as an internal control for the present study.

Several limitations should be acknowledged. The retrospective design introduces potential bias, especially selection bias. Precise information on test timing was unavailable, which may have impacted results if platelet function fluctuated within the 3-day postoperative period classified as “immediately after surgery.” Antiplatelet therapy was modified in some patients during the 1-month follow-up period based on the procedure type and clinical condition. Therefore, the observed longitudinal changes cannot necessarily be attributed solely to the procedure. However, at each measurement time point, all five platelet function tests were performed using samples collected under the same treatment condition. Thus, treatment modification was considered more relevant to the interpretation of longitudinal changes than to the primary within-time-point comparisons among the testing methods. Moreover, the correlation between clinical events and test outcomes was not explored, underscoring the need for further studies to clarify the clinical relevance of the various testing methods presented.

In conclusion, the five platelet function tests showed different response patterns and were not necessarily interchangeable. Perioperative changes were detected by 1 mM AA MA in this cohort, but the clinical significance of this finding remains to be established.

Supporting information

References

  1. 1. Cattaneo M. Resistance to antiplatelet drugs: molecular mechanisms and laboratory detection. J Thromb Haemost. 2007;5 Suppl 1:230–7. pmid:17635731
  2. 2. Cattaneo M. Aspirin and clopidogrel: efficacy, safety, and the issue of drug resistance. Arterioscler Thromb Vasc Biol. 2004;24(11):1980–7. pmid:15388526
  3. 3. Colantonio LD, Gamboa CM, Kleindorfer DO, Carson AP, Howard VJ, Muntner P, et al. Stroke symptoms and risk for incident coronary heart disease in the REasons for Geographic And Racial Differences in Stroke (REGARDS) study. Int J Cardiol. 2016;220:122–8. pmid:27376567
  4. 4. Breet NJ, van Werkum JW, Bouman HJ, Kelder JC, Ten Berg JM, Hackeng CM. High on-aspirin platelet reactivity as measured with aggregation-based, cyclooxygenase-1 inhibition sensitive platelet function tests is associated with the occurrence of atherothrombotic events. J Thromb Haemost. 2010;8(10):2140–8. pmid:20723029
  5. 5. Le Blanc J, Mullier F, Vayne C, Lordkipanidzé M. Advances in platelet function testing-light transmission aggregometry and beyond. J Clin Med. 2020;9(8):2636. pmid:32823782
  6. 6. Venketasubramanian N, Agustin SJ, Padilla JL, Yumul MP, Sum C, Lee SH, et al. Comparison of different laboratory tests to identify “aspirin resistance” and risk of vascular events among ischaemic stroke patients: a double-blind study. J Cardiovasc Dev Dis. 2022;9(5):156. pmid:35621867
  7. 7. Paniccia R, Antonucci E, Gori AM, Marcucci R, Poli S, Romano E, et al. Comparison of different methods to evaluate the effect of aspirin on platelet function in high-risk patients with ischemic heart disease receiving dual antiplatelet treatment. Am J Clin Pathol. 2007;128(1):143–9. pmid:17580282
  8. 8. Matsubara H, Mizutani D, Egashira Y, Enomoto Y. Perioperative antiplatelet therapy for the stent-assisted coil embolization: results of the questionnaire survey. J Neuroendovasc Ther. 2023;17(2):56–60. pmid:37502130
  9. 9. Enriquez-Marulanda A, Filo J, Ramirez-Velandia F, Fodor T, Sconzo D, Young M, et al. Defining light transmission aggregometry cutoff values for clopidogrel and aspirin resistance in flow diversion treatment of intracranial aneurysms. J Neurosurg. 2024;141(5):1168–76. pmid:38820610
  10. 10. Born GVR. Aggregation of blood platelets by adenosine diphosphate and its reversal. Nature. 1962;194:927–9. pmid:13871375
  11. 11. Cattaneo M, Cerletti C, Harrison P, Hayward CPM, Kenny D, Nugent D, et al. Recommendations for the standardization of light transmission aggregometry: a consensus of the working party from the platelet physiology subcommittee of SSC/ISTH. Journal of Thrombosis and Haemostasis. 2013;11(6):1183–9.
  12. 12. Prüller F, Milke OL, Bis L, Fruhwald F, Scherr D, Eller P, et al. Impaired aspirin-mediated platelet function inhibition in resuscitated patients with acute myocardial infarction treated with therapeutic hypothermia: a prospective, observational, non-randomized single-centre study. Ann Intensive Care. 2018;8(1):28. pmid:29468430
  13. 13. Gasparyan AY. Aspirin and clopidogrel resistance: methodological challenges and opportunities. Vasc Health Risk Manag. 2010;6:109–12. pmid:20448796
  14. 14. Lawrie AS, Kobayashi K, Lane PJ, Mackie IJ, Machin SJ. The automation of routine light transmission platelet aggregation. Int J Lab Hematol. 2014;36(4):431–8. pmid:24237750
  15. 15. Ling L-Q, Liao J, Niu Q, Wang X, Jia J, Zuo C-H, et al. Evaluation of an automated light transmission aggregometry. Platelets. 2017;28(7):712–9. pmid:28150526
  16. 16. Frère C, Kobayashi K, Dunois C, Amiral J, Morange P-E, Alessi M-C. Assessment of platelet function on the routine coagulation analyzer Sysmex CS-2000i. Platelets. 2018;29(1):95–7. pmid:28960123
  17. 17. Bret V-E, Pougault B, Guy A, Castet S, Huguenin Y, Pillois X, et al. Assessment of light transmission aggregometry on the routine coagulation analyzer Sysmex CS-2500 using CE-marked agonists from Hyphen Biomed. Platelets. 2019;30(4):540–2. pmid:30311818
  18. 18. Mirandari YNI, Fuadi MR, Ardhi MS. Comparison of the diagnostic performance of platelet aggregation test using light transmission aggregation (LTA), method. J Med Chem Sci. 2024;7:500–7.
  19. 19. Lecchi A, Capecchi M, Padovan L, Artoni A, Arai N, Shinohara S, et al. Evaluation of an automated platelet aggregation method for detection of congenital or acquired platelet function defects. Blood Transfus. 2024;22(4):350–9. pmid:38315534
  20. 20. Naveena D, Yogalakshimi D, Ramya D. Precision in the thrombocyte functional array: automated aggregometry for decoding congenital and acquired dysfunction. Test Psychometr Methodol Appl Psychol. 2025;32(Suppl 4):1213–9.
  21. 21. Sakayori T, Watanabe Y, Kitano K, Matsui Y, Karino D, Arai N, et al. Evaluating the utility of a novel research use index in Platele aggregation analysis featured in an automated blood coagulation analyzer to confirm the effect of Antiplatelt drugs. SYSMEX J Int. 2019;29:39–47.
  22. 22. Sakayori T, Egashira M, Nakajima K, Kono M, Kitano K, Iwasaki Y. Analytical evaluation of platelet aggregation level on a fully automated coagulation analyzer CN-6000, and a case study of an initial absorbance of platelet-rich plasma. SYSMEX Journal International. 2024;34:1–11.
  23. 23. Kitano K, Sakayori T, Tsuboi Y, Ishida H, Arai N, Uematsu K, et al. Evaluation of collagen-induced platelet aggregation level score using an automated coagulation analyzer. Clin Lab. 2026;72(2):10.7754/Clin.Lab.2025.250329. pmid:41670513
  24. 24. Enomoto Y, Matsubara H, Ishihara T, Shoda K, Mizutani D, Egashira Y, et al. Optimal duration of dual antiplatelet therapy for stent-assisted coiling or flow diverter placement. J Neurointerv Surg. 2024;16(5):491–7. pmid:37344176
  25. 25. van Werkum JW, Harmsze AM, Elsenberg EHAM, Bouman HJ, ten Berg JM, Hackeng CM. The use of the VerifyNow system to monitor antiplatelet therapy: a review of the current evidence. Platelets. 2008;19(7):479–88. pmid:18979359
  26. 26. Sakayori T, Nakanishi R, Shoda K, Ueno Y, Kanbe A, Oka A, et al. Comparative study of four platelet function tests conducted using two systems in neuroendovascular patients. Sci Rep. 2025;15(1):33437. pmid:41023057
  27. 27. Schiera E, De Corci S, Terracina S, Galardo G, Di Pietro G, Mancone M, et al. Interindividual variability in platelet aggregation among aspirin-treated patients: a large retrospective analysis. Blood Vessel Thromb Hemost. 2026;3(4):100204. pmid:42861038
  28. 28. Ben-Dor I, Kleiman NS, Lev E. Assessment, mechanisms, and clinical implication of variability in platelet response to aspirin and clopidogrel therapy. Am J Cardiol. 2009;104(2):227–33. pmid:19576352
  29. 29. Conti V, Corbi G, Manzo V, Sellitto C, Iannello F, Esposito S, et al. The role of pharmacogenetics in antithrombotic therapy management: new achievements and barriers yet to overcome. Curr Med Chem. 2021;28(32):6675–703. pmid:33390104
  30. 30. Platton S, McCormick Á, Bukht M, Gurney D, Holding I, Moore GW. A multicenter study to evaluate automated platelet aggregometry on Sysmex CS-series coagulation analyzers-preliminary findings. Res Pract Thromb Haemost. 2018;2(4):778–89. pmid:30349897
  31. 31. Yoshida M, Oura K, Shimizu M, Natori T, Narumi S, Tsuda K, et al. Determination of the reference range of platelet aggregation using a new automatic coagulation analyzer and visualization of platelet function data. Thromb Res. 2020;194:95–7. pmid:32788127