Figures
Abstract
Purpose
To identify pre/perioperative factors that predict graft failure after Descemet membrane endothelial keratoplasty (DMEK).
Methods
This retrospective cohort study included consecutive eyes that underwent DMEK in 2015–2023 in a regional referral hospital and were followed for at least 12 months. DMEK-graft failure was defined as need for regrafting during follow-up. Univariable analysis of graft-failure associations with 20 covariates was performed. Hierarchical multivariable analysis was conducted for DMEK-graft failure with covariates whose univariable-analysis p-values were ≤0.15. Posthoc univariable analyses were performed to elucidate the mechanisms by which covariates promoted DMEK-graft failure.
Results
171 eyes (129 patients) with mostly Fuchs endothelial corneal dystrophy (94%) were included. Median (range) follow-up was 24 (12–29) months, during which 15 grafts (9%) failed. On univariable analyses, graft failure associated with eight variables, including long (≥25 mm) preoperative axial length (AXL): 40% of graft-failure eyes had AXL ≥ 25 mm vs. 13% for graft-success eyes (p = 0.01). On multivariable analysis, graft failure was predicted by AXL ≥ 25 mm (OR=5.70; 95%CI = 1.27–25.68; p = 0.02), younger graft-donor age (OR=0.93; 95%CI = 0.88–0.99; p = 0.02), graft-unscrolling/positioning difficulties (OR=6.93; 95%CI = 1.58–30.48; p = 0.01), and major graft detachment (OR=6.28; 95%CI = 1.36–28.96; p = 0.02). The model accounted for 14% of total graft-failure variance. Posthoc univariable analysis showed that eyes with AXL ≥ 25 experienced graft-unscrolling/positioning difficulties more often than shorter eyes (27% vs. 10%, p = 0.0497).
Conclusions
Eyes with long AXL (≥25 mm) may be more prone to DMEK-graft failure than shorter eyes. This may reflect the deep anterior chamber, which can complicate graft unscrolling and/or graft positioning. The additional graft handling may induce endothelial-cell loss and subsequent graft failure. Younger donor age weakly predicted DMEK-graft failure, possibly due to tighter scrolling of younger grafts. Major graft detachment strongly predicted DMEK-graft failure. This could reflect surgical and/or rebubbling-induced endothelial damage and/or pre-existing graft weakness.
Citation: Mastrangelo L, Leterrier J, Goetz C, Zevering Y, Perone J-M (2026) Preoperative and perioperative factors that predict graft failure 1 year after Descemet membrane endothelial keratoplasty. PLoS One 21(7): e0352687. https://doi.org/10.1371/journal.pone.0352687
Editor: Rajiv R. Mohan, University of Missouri-Columbia, UNITED STATES OF AMERICA
Received: March 17, 2026; Accepted: June 13, 2026; Published: July 24, 2026
Copyright: © 2026 Mastrangelo et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: The datasets generated during and/or analyzed during the current study are not publicly available according to French Law No. 2018-493 of June 20, 2018 on the protection of personal data (The General Data Protection Regulation (Regulation (EU) 2016/679) (GDPR: article 9) but are available from the Clinical Research Support Platform (Plateforme d’Appui à la Recherche Clinique [PARC]) of the Regional Central Hospital (CHR) of Metz-Thionville on reasonable request (email: projet-recherche-clinique@chr-metz-thionville.fr, tel: +33 3 87 17 98 82). All non-archived data is subject to daily backups while all archived data is subject to duplicate storage at two different sites. This data processing is compliant with a baseline reference methodology (MR-001) to which the CHR MetzThionville signed a compliance commitment on October 8, 2018.
Funding: The author(s) received no specific funding for this work.
Competing interests: The authors have declared that no competing interests exist.
Introduction
Descemet membrane endothelial keratoplasty (DMEK) is a corneal-transplantation method that involves peeling off a disc of diseased corneal endothelium and its overlying Descemet membrane, replacing it with a disc of donor tissue composed of healthy endothelium and Descemet membrane, and pinning the graft against the recipient cornea with a bubble of air or 20% sulfur hexafluoride (SF6) that wanes over the next few days and weeks, respectively [1,2]. DMEK is the gold standard for corneal-endothelial pathologies [3], including Fuchs endothelial corneal dystrophy (FECD), a genetic condition characterized by progressive loss of endothelial cells and eventual corneal stromal swelling that induces halos, discomfort, and visual-acuity loss [4]. DMEK is also used to treat bullous keratopathy (BK), where ocular surgery such as phacoemulsification has traumatized the endothelium [3], and graft failure after previous keratoplasties, including Descemet stripping automated endothelial keratoplasty (DSAEK) and penetrating keratoplasty (PKP) [5].
The thinness of the DMEK graft (15 µm) results in superior visual outcomes compared to DSAEK (45–180 µm-thick grafts) and PKP (full-thickness grafts) [6–9]. However, this thinness together with the elasticity of Descemet membrane also means DMEK grafts form tight scrolls that must be unfurled in the recipient anterior chamber. A common approach is to gently tap the cornea with two 27-gauge cannulas, after which the unfurled graft is positioned against the exposed recipient stroma with the air or gas bubble. However, this procedure can be complicated by incomplete graft unscrolling, graft rescrolling, and difficult graft positioning, which require additional maneuvers that further stress the graft and exacerbate donor endothelial-cell loss (ECL) [10–13]. The scroll-prone graft also tends to detach from the recipient bed, which can require early postoperative rebubbling. However, rebubbling could potentially also induce ECL [11,14–21]. Since (i) DMEK associates with 30–50% graft ECL in the first 6 postoperative months [22,23], (ii) DMEK accelerates aging-related ECL from 0.6–0.7%/year to ~4%/year [22,23], and (iii) postoperative graft endothelial-cell counts of 250–500 cells/mm2 associate strongly with graft failure [22–24], surgeons remain concerned about DMEK-graft longevity. Indeed, up to 13% and 6% of DMEK grafts respectively fail in the first few postoperative months and within the next 5 years [25].
Given these concerns, it would be useful to know which preoperative and perioperative factors predict DMEK-graft failure, since this could help identify at-risk patients and/or strategies that reduce DMEK-graft failure. However, few studies have focused on DMEK-graft failure specifically (S1 Table) [20,26–37]. Most studies instead use ECL, graft detachment, or rebubbling as surrogate measures of graft failure (e.g., [38–43]), probably because graft-failure sample sizes are generally small. However, ECL is generally unmeasurable in early-failure cases and only ~30% of graft detachment/rebubbling cases actually undergo graft failure [20]. Moreover, graft detachment and surgery-induced endothelial decompensation cannot explain all DMEK-graft failures [44,45]: multiple studies show that graft failure can also be caused by undetected ultrastructural graft aberrations and graft disease (e.g., early-stage pseudoexfoliation-associated keratopathy and corneal guttata) [45–49], disease recurrence [50], immune rejection, intraocular-pressure elevation, and wound dehiscence [25,50]. Thus, the surrogate variables do not fully represent DMEK-graft failure. Moreover, some of the few studies on DMEK-graft failure itself conducted univariable rather than multivariable analyses (S1 Table) [20,26–37]. Some potential risk factors have also been poorly researched, including ocular anatomical variables such as axial length (AXL) or anterior-chamber depth (ACD): while two studies suggest that they could affect DMEK-graft unfolding and promote ECL [51,52], others have not observed this [53–55] and their contribution to DMEK-graft failure has not been studied. Similarly, although 20% SF6 is increasingly being used instead of air alone for endotamponade due to longer bubble persistence [56], the effect of using SF6 on DMEK-graft failure has rarely been assessed [27,28]. Moreover, although DMEK graft-unscrolling/positioning difficulties can induce ECL [10–13], their direct influence on graft failure has not been examined.
To identify factors that could specifically shape DMEK-graft failure, we subjected our unselected cohort of DMEK patients to univariable and multivariable analyses to determine the relationships between DMEK-graft failure and 20 pre/perioperative factors, including ocular-anatomy variables, SF6 use, and graft-unscrolling/positioning difficulties. Posthoc analyses were also conducted to elucidate potential underlying mechanisms by which the predictive pre/perioperative factors shape DMEK-graft failure.
Methods
Study design and ethics
This retrospective single-center cohort study was conducted in the Ophthalmology Department of the Metz-Thionville Regional Hospital (Grand Est, France). It was approved by the Ethics Committee of the French Society of Ophthalmology (Institutional Review Board No. 00008855) and registered on ClinicalTrials.gov (Identifier: NCT06859411). All procedures were conducted in accordance with the principles of the Declaration of Helsinki. Before surgery, all patients were informed that their surgery-related data might be used for research. All consented to this possibility in writing. The consent procedure was conducted according to the reference methodology MR-004 of the National Commission for Information Technology and Liberties of France (No. 588909 v1). The data were accessed for research purposes on 7 April 2025. Only the first and corresponding authors had access to information that could identify individuals during or after data collection.
Patient selection
The prospectively maintained medical records were searched for all consecutive adult (≥18 years) patients who underwent primary DMEK in 1 October 2015–30 April 2023 and were followed for at least 12 months. Patients whose surgeries involved graft-dissection problems (tearing or splitting of the graft, or dissection resulting in an imperfect graft shape) were excluded because graft-preparation difficulties can damage the graft and increase graft failure [57] and we wanted to focus on the outcomes of apparently viable grafts. This was because many centers use eye bank-prepared DMEK grafts [38] and we wanted our study to be relevant to this setting as well. Patients with history of vitrectomy were excluded because vitrectomy also associates with more graft failure [58]. One eye that developed unusually severe endothelial damage was excluded because it was not clear whether the graft failure was due to rejection or viral infection or both. Other rejection cases were not a priori excluded. Eyes with missing AXL and/or ACD data were also excluded. To assess the effect of these exclusions on our findings, we repeated our multivariable analysis with all consecutive patients.
Preoperative, perioperative, and postoperative measurements
Preoperative AXL, ACD, and lens thickness of the operative eye were measured with a biometer (IOLMaster 700; Zeiss Co., Oberkochen, Germany). BSCVA (expressed in logMAR) was measured before and 8 and 15 days and 1, 3, 6, and 12 months after surgery. Anterior-segment optical coherence tomography (NIDEK with a special module; Nidek Co., Gamagori Aichi, Japan) was conducted at all postoperative timepoints to determine graft adherence. Operative time from starting graft dissection to placing the suture at the end of surgery was measured by a nurse with a stopwatch. Preoperative graft ECD was determined by manual counting under an optic microscope by an eye-bank technician followed by a recount by another technician.
Surgical techniques, postoperative care, and follow-up
During the preoperative consultation, all patients underwent lower peripheral iridotomy with Nd:YAG Laser (Laser ex-Super Q; Ellex Europe, Medical Quantel, Cournon d’Auvergne, France) at the 6 o’clock position to prevent pupillary block during and after DMEK surgery. All surgeries were performed by the same experienced surgeon (JMP). General anesthesia was used unless it was contraindicated, in which case surgery was performed under peribulbar block with a 50:50 mixture of ropivacaine 7.5 mg/mL and lidocaine 2% that was administered with a 23-gauge Atkinson cannula.
DMEK was conducted as described previously [2]. Unprepared corneoscleral buttons were obtained from the tissue banks in Besançon or Nancy, France. All were preserved in CorneaMax organ-culture medium (Eurobio; Courtaboeuf, France) at 31°C. All had a requested endothelial-cell density (ECD) of >2200 cells/mm². These preoperative ECD measurements were made just before transport, which occurred 3–4 weeks after button harvest. For transport, the buttons were placed in dextran-containing transport medium (CorneaJet; Eurobio) and shipped to our hospital the day before surgery. They were exposed to the transport medium for 3 days. DMEK grafts were generated from the corneoscleral buttons immediately before surgery. Specifically, in the operating room, each graft was trephined to an 8 mm-diameter disc with Hanna’s microtrephine (Busin Punch 17200D 8-mm single use; Moria SA, Antony, France). The Descemet membrane-endothelium complex was then manually stripped from the corneal stroma with disposable curved forceps (Single Use Tying Forceps Curved 5 mm Platform 17501; Moria SA) under a microscope. The graft was stained with Trypan Blue (Vision Blue, 0.5-mL syringe; DORC [Dutch Ophthalmic Research Center], Zuidland, Netherlands]), marked with “F” or “F*” on its stromal side with a gentian-violet surgical pen (Devon Skin Marker; Covidien, Mansfield, USA), and placed into a customized injector (30G Curved cannula for air injection; DORC).
If the recipient eye had concomitant anterior corneal surface pathology, superficial keratectomy was conducted with alcohol delamination, followed by polishing with a cellulose sponge and irrigation. The central surface of the recipient cornea was marked with an 8 mm-diameter circular marker and the main paracentesis was placed supero-temporally (right eye) or supero-nasally (left eye) with a 2.2-mm blade (Securityblade BD, Xstar 2.2-mm, 45 degrees, 37822; Beaver-Visitec International, Waltham, USA). A second incision was made with a Worst 15 blade (Ophthalmic Knife 15 degrees; ALCON, Rueil Malmaison, France). A 9 mm-diameter central descemetorhexis was performed along the circular marks on the cornea with an inverted Sinskey Price hook (Single Use Price Reverse Hook Sim 17302; Moria SA) and an inverted spatula (90th single use Spatula 17303; Moria SA) under sterile air infusion. The main incision was enlarged to 4 mm and the graft was injected into the anterior chamber via the DORC injector. The graft was unscrolled by applying external corneal pressure and taps with two 27-gauge Rycroft cannulas. Once positioned, a sterile air or 20% SF6 bubble was injected into the anterior chamber to secure the graft. We used air for endotamponade until September 2020, at which point we switched to SF6 for all new eyes. The main incision was sutured with one point of Nylon 10.0, which was subsequently buried.
All phakic eyes also underwent simultaneous cataract surgery (triple-DMEK). All remaining eyes were pseudophakic before DMEK. In triple-DMEK cases, phacoemulsification was performed immediately before DMEK using a standard supracapsular “garde à vous” technique [59] with the Stellaris PC (Bausch and Lomb, Aliso Viejo, CA, USA). A Zeiss CT Asphina 409MV intraocular lens was implanted in the capsular bag, targeting a residual myopia of 0.5–1.0 diopters to counteract the expected post-DMEK hyperopic shift [60]. Carbachol 0.01% (Miostat; ALCON) was used to induce miosis, which facilitated the subsequent DMEK procedure.
After DMEK, 1 ml cefuroxime 50 mg (Aprokam; Thea Laboratory, Clermont-Ferrand, France) was injected intracamerally into the air/gas bubble and acetazolamide 500 mg (Diamox; Sanofi, Gentilly, France) was infused. The patients were treated four times/day with eyedrops containing dexamethasone, neomycin, and polymyxine B (Maxidrol; ALCON), the non-steroidal anti-inflammatory drug indometacine 0.1% (Indocollyre; Bausch and Lombe, Montpellier, France), and a vitamin A-containing ophthalmic ointment (Vitamin A dulcis; Laboratoire Allergan, Courbevoie, France) for 1 month. Indometacine and the ointment were then stopped and Maxidrol was replaced with low-dose corticosteroid eye drops (Flucon; Novartis Pharma, Rueil Malmaison, France), which were administered three times/day for 2 months, twice/day for the next year, and then once/day for generally 5 years.
After surgery, the patients were followed up at days 8 and 15, months 1, 3, 6, and 12, and every year thereafter. Patients who developed CME were treated with oral acetazolamide (Diamox; one 250 mg tablet three times/day for 1 month) and indometacine (four times/day for 1 month) or, in complex cases, with intravitreal injection of dexamethasone (Ozurdex 700 µg implant i-vitr; Laboratoire Allergan). Patients with graft rejection were treated with dexamethasone with oxytetracycline ointment (Sterdex; Thea, Clermont-Ferrand, France; twice/day) and Maxidrol eyedrops (Alcon; 12 times/day for 1 week followed by tapering for several weeks).
If ≥30% of the graft had detached and/or the detachment threatened the visual axis, it was considered major graft detachment. In all cases, as well as in some early cases where the detachment was more minor, rebubbling with sterile air was conducted under topical anesthesia. Rebubbling was repeated if considered necessary.
If non-adhesion continued despite up to four rebubblings, corneal edema persisted after 3 months, and/or new corneal edema arose during follow-up, the graft was considered to have failed and regrafting with DMEK or DSAEK was planned.
Collected variables and definitions
The data of the following variables were collected: patient age and sex; operative eye side; indication; preoperative recipient AXL, ACD, and lens thickness (note that the latter data could not be collected for eyes that were pseudophakic before DMEK); preoperative and 12-month postoperative BSCVA; graft-donor age and preoperative ECD; use of general anesthesia; use of triple-DMEK; graft-unscrolling/positioning difficulties; use of SF6 for endotamponade; operative time; presence of a bubble under the iris; presence of major graft detachment; number of rebubblings (0, 1, ≥ 2); graft rejection; development of CME; and graft failure. Graft-unscrolling/positioning difficulties were defined according to Maier et al. [12], namely, difficult unfolding and centering (duration longer than 5 minutes) that required repeated air injection and balanced salt solution exchange or even direct manipulation of the graft with forceps. Major graft detachment was defined as detachment that affected the graft center and/or >30% of the graft surface and therefore required rebubbling. Graft failure was defined as need for a new graft during follow-up due to any reason, including failure caused by rejection. Patients whose graft failed but eschewed a regraft were still considered graft-failure cases.
Statistical analysis
Continuous data were expressed as median and interquartile range (IQR). Categorical data were expressed as n (%). Since our exploratory univariable analyses showed that longer AXL associated with graft failure (see Results), and eyes with ≥25-mm AXL seemed markedly more prone to graft failure than eyes with AXL < 25 mm (Fig 1), we expressed AXL as both a continuous and categorical variable (i.e., < 25 mm and ≥25 mm). The univariable relationships between graft failure and the 20 preoperative and perioperative variables were then determined with generalized linear regression with a random factor on the patient: this test was used rather than standard univariable analyses (e.g. Fisher’s exact test) because a third of patients underwent bilateral DMEK, which contravenes the assumption of sample independence. All independent variables that had a p-value of ≤0.15 on univariable analysis were considered for inclusion in a generalized multiple linear regression analysis to determine their ability to predict graft failure. This regression analysis was also conducted with a random factor on the patient to account for the bilateral DMEK cases. Before multivariable analysis was conducted, eigenvalues and eigenvectors were determined to assess collinearity between the independent variables. If collinearity was detected between two independent variables, the most clinically relevant variable was retained in the multivariable analysis. AXL was expressed as a categorical variable in the multivariable analysis to determine the clinical applicability of the ≥ 25-mm threshold. However, this analysis was also repeated with AXL expressed as a continuous variable. All multivariable-analysis data were expressed as Odds Ratio (OR) and 95% confidence intervals (95%CI). Missing data were ignored in all analyses. To depict the time course of graft failures, Kaplan-Meier survival analysis was conducted. To assess the effect of excluding cases with graft-dissection problems, vitrectomy, missing data, and complicated rejection/infection on our multivariable-analysis findings, we repeated this analysis with all consecutive patients. P-values <0.05 were considered to indicate statistical significance. All statistical analyses were performed with SAS software (version 9.4, SAS Inst., Cary, NC, USA).
Posthoc statistical analyses
Our multivariable analyses revealed that two variables, namely, longer AXL and graft-unscrolling/positioning difficulties, were strong predictors of graft failure (see Results). We hypothesized that longer AXL might promote graft failure indirectly by inducing graft unscrolling/positioning difficulties because (i) longer AXL correlates positively with deeper ACD [61–63] and (ii) studies suggest that DMEK-graft unscrolling is difficult in deep anterior chambers because the graft spins on tapping rather than unfurling [14,64–66]. To test our hypothesis, the univariable relationships between all significant predictors in the multivariable analysis were determined with posthoc generalized linear regressions with a random factor on the patient. To determine whether the relationships detected by these univariable analyses could have confounded the first multivariable analyses, posthoc multivariable analyses that excluded single graft-failure predictors were also conducted.
The relationships between AXL and the collinear variables that were excluded from the first multivariable analyses due to collinearity were also determined with posthoc generalized linear regressions with a random factor on the patient.
Results
During the study period, 188 eyes of 137 patients underwent DMEK. Of these, 17 eyes from eight patients were excluded due to graft-dissection problems (n = 12), a history of vitrectomy (n = 1), and missing preoperative AXL and/or ACD values (n = 4). One unusual case with extremely severe endothelial damage that required regraft with PKP was excluded because it was not possible to determine whether rejection and/or viral endothelitis was the cause of graft failure. Thus, 170 eyes of 128 patients were included in this study (Fig 2). The median (IQR; range) follow-up duration of these 170 eyes was 24 (12–24; 12–29) months.
ACD, anterior chamber depth; AXL, axial length. DMEK, Descemet membrane endothelial keratoplasty.
Preoperative and operative cohort characteristics and postoperative outcomes
The data were complete for all eyes except preoperative BSCVA was missing for one eye and preoperative lens thickness was missing for two triple-DMEK eyes (and all 82 pseudophakic-DMEK eyes). The 128 patients had a median age of 72 years, 66% were women, and 33% underwent bilateral DMEK. The indications in the 170 operative eyes were FECD (94%), pseudophakic BK (3%), regraft (3%), and post-uveitis (1%). Median preoperative AXL was 23 mm, and 144 (85%) and 26 (15%) eyes had AXL < 25 mm and AXL ≥ 25 mm, respectively (Fig 1). Median graft donor age was 74 years. Other descriptive data are shown in Table 1.
In 22 eyes (13%), we experienced graft-unscrolling/positioning difficulties that lengthened this procedure to more than 5 minutes, necessitating repeated air injection with balanced salt solution exchange and in some cases requiring direct graft manipulation with forceps. SF6 was used for endotamponade in 37% and median operative time was 35 minutes. A bubble appeared under the iris in three eyes (2%). Major graft detachment necessitating rebubbling was observed in 25 eyes (15%). Another 30 eyes (18%) from early in the series were also rebubbled despite more minor graft detachment. Thus, 55 eyes (32%) underwent rebubbling. A single rebubble and ≥2 rebubbles were conducted in 37 (22% of all eyes) and 18 (11%) eyes, respectively. There were 13 cases of CME (8%), all of which resolved with treatment, and no cases of rejection. During follow-up, 15 (9%) of the eyes had experienced graft failure (Table 1). Of these 15 grafts, seven (47%), three (20%), two (13%), and three (20%) failed at ≤3 months, 4–6 months, 7–12 months, and >12 months, respectively. The median (IQR) duration to graft failure was 5 (2–9) months. Fig 3 shows when the 15 grafts failed during follow-up. The median 12-month BSCVA of the eyes whose graft survived was 0.08 logMAR.
The plot was generated with Kaplan-Meier analysis.
Univariable and multivariable associations between graft failure and pre/perioperative variables
Generalized linear regression analysis with a factor on the patient (which accounted for the bilateral-DMEK cases) showed that the eyes that developed graft failure had significantly longer median preoperative AXL (25 vs. 23 mm for the graft-success eyes, p = 0.02). The graft-failure eyes were also 3-fold more likely to have a preoperative AXL of ≥25 mm than the graft-success eyes (40% vs. 13%, p = 0.01). Moreover, the graft-failure eyes experienced significantly more graft-unscrolling/positioning difficulties (40% vs. 10%, p = 0.005), major graft detachment (33% vs. 13%, p = 0.048), and multiple rebubbling (33% vs. 8%, p = 0.04). Women tended to be more likely to experience graft failure than men (87% vs. 64%, p = 0.11). Graft failure tended to associate with younger donor age (70 vs. 75 years, p = 0.06), longer operative times (40 vs. 35 min in graft-success cases, p = 0.07), and thicker preoperative lens thickness (4.78 vs. 4.76 mm, p = 0.10). Other variables did not associate with graft failure, including preoperative BSCVA and ACD and use of triple-DMEK and SF6 (Table 2).
All eight variables whose p-value in univariable analysis was ≤ 0.15 were then considered for inclusion in the multivariable analysis. However, the eigenvalues and eigenvectors showed that operative time was collinear with graft-unscrolling/positioning difficulties (r = 0.49, p < 0.0001) and rebubbling was collinear with major graft detachment (r = 0.59, p < 0.0001). Being less clinically relevant, operative time and rebubbling were excluded. Lens thickness was also excluded due to unavailable data in the pseudophakic-DMEK cases. Thus, multivariable analysis adjusted for the bilateral cases was conducted with patient sex, preoperative AXL (expressed as <25 and ≥25 mm categories), donor age, graft-unscrolling/positioning difficulties, and major graft detachment. Four of these five variables significantly predicted graft failure, namely, preoperative AXL ≥ 25 mm (OR=5.70, 95%CI = 1.27–25.68, p = 0.02), younger donor age (OR=0.93, 95%CI = 0.88–0.99, p = 0.02), graft-unscrolling/positioning difficulties (OR=6.93, 95%CI = 1.58–30.48, p = 0.01), and major graft detachment (OR=6.28, 95%CI = 1.36–28.96, p = 0.02). The fifth variable, female patient sex, tended to predict graft failure (OR=5.48, 95%CI = 0.76–39.58, p = 0.09). The model accounted for 14% of the total graft-failure variance (R2) (Table 3). Similar data were observed when AXL was expressed as a continuous variable (S2 Table).
To assess the effect of excluding the 18 eyes with graft-dissection problems, vitrectomy, missing data, and unusual rejection/infection features from our study cohort, we repeated the multivariable analysis. Very similar results were obtained (S3 Table).
Posthoc analysis of the relationship between AXL and graft-unscrolling/positioning difficulties
Both preoperative AXL > 25 mm and graft-unscrolling/positioning difficulties were strong predictors of graft failure on multivariable analysis (OR=5.70 and 6.93, respectively; Table 3). This indicates that these variables predict graft failure independently of each other. However, we speculated that longer AXL could also induce graft failure via a more indirect pathway, namely, by driving graft-unscrolling/positioning difficulties. This is supported by the fact that longer AXL correlates with deeper ACD [61–63] and deep anterior chambers hamper DMEK-graft unscrolling [14,64–66]. Since multivariable analyses are not necessarily able to detect such indirect mechanisms [67], we tested the notion that longer AXL promotes graft failure by inducing graft-unscrolling/positioning difficulties by assessing the inter-relationships between the four graft-failure predictors. These univariable analyses showed that there was only one significant relationship: eyes with AXL ≥ 25 mm were more than twice as likely to experience graft-unscrolling/positioning difficulties than eyes with AXL < 25 mm (27% vs. 10%, p = 0.0497) (Table 4).
This relationship between preoperative AXL > 25 mm and graft-unscrolling/positioning difficulties was not detected by collinearity assessment with eigenvalues and eigenvectors before multivariable analysis, likely reflecting the modest relationship between these variables. To test that this relationship did not markedly affect the predictive performance of the logistic regression model in Table 3, we excluded either preoperative AXL > 25 mm or graft-unscrolling/positioning difficulties from the multivariable analysis. These posthoc analyses showed that regardless of these exclusions, all significant predictors continued to predict graft failure, including graft-unscrolling/positioning difficulties (OR=8.34, 95%CI = 2.09–33.29, p = 0.004) (S4 Table) and preoperative AXL ≥ 25 mm (OR=6.92, 95%CI = 1.77–27.04, p = 0.01) (S5 Table).
Since operative time and rebubbling were excluded from the multivariable analysis in Table 3 due to collinearity with graft-unscrolling/positioning difficulties (r = 0.49, p < 0.0001) and major graft detachment (r = 0.59, p < 0.0001), respectively, we also asked whether AXL associated with these variables on univariable analysis. Consistent with the collinearity patterns and the univariable association between AXL and graft-unscrolling/positioning difficulties (Table 4), AXL ≥ 25 mm tended to associate with longer operative time (38 vs. 30 min for the AXL ≤ 25 mm subgroup, p = 0.07) but not rebubbling (15% rebubbling rate vs. 12% for the AXL < 25 mm subgroup, p = 0.73).
Discussion
This study showed that longer preoperative AXL, younger donor age, graft-unscrolling/positioning difficulties, and major graft detachment independently predicted DMEK-graft failure. On univariable analysis, rebubbling also associated significantly with graft failure, reflecting its collinearity with major graft detachment, while longer operative time tended to associate with graft failure, reflecting its collinearity with surgical difficulties. Posthoc univariable analyses suggested that longer AXL could also indirectly induce graft failure by promoting graft-unscrolling/positioning difficulties.
The demographics and indications of our cohort are similar to those in previous studies on factors that shape DMEK-graft failure (S1 Table) [20,26–37]. The DMEK-graft failure rate of our cohort was 9%, consistent with that reported by a Dutch registry study on 752 cases (11%) [20]. BSCVA dropped from 0.5 to 0.08 logMAR in our cohort, similar to the good DMEK visual outcomes reported elsewhere [20,37,68–70].
Putative mechanisms by which AXL and graft-unscrolling/positioning difficulties promote DMEK-graft failure
Both AXL ≥ 25 mm and graft-unscrolling/positioning difficulties independently predicted graft failure on multivariable analysis (OR=5.70 and 6.93, respectively). However, AXL ≥ 25 mm also associated with more graft-unscrolling/positioning difficulties on posthoc univariable analysis (p = 0.0497). Thus, AXL ≥ 25 mm may promote graft failure (i) indirectly by inducing graft-unscrolling/positioning difficulties and (ii) directly by another mechanism that is independent of graft-unscrolling/positioning difficulties. The putative mechanisms are discussed below.
Long AXL may promote graft failure by hampering graft unscrolling.
Fig 4 shows a schematic depiction of the possible mechanisms by which the four predictors could induce graft failure. The hypothesis that long AXL indirectly induces graft failure is depicted by the broken red arrow. This four-part hypothesis proposes that (1) long AXL signifies a more capacious anterior chamber [61–63] that (2) complicates graft unscrolling in the anterior chamber, which (3) increases graft handling that induces extensive ECL, which (4) in turn leads to graft decompensation and failure. With regard to Part 2, it is well known that successful unscrolling with the tapping method requires an optimally shallow anterior chamber. Specifically, in an optimally shallow anterior chamber, the DMEK scroll touches both the cornea and iris. Consequently, on tapping, which generates fluid currents, the scroll not only unfurls, it also remains unfurled. However, in deep anterior chambers, the scroll lacks contact with the iris/cornea and quickly refurls after tapping induces some unscrolling. Notably, a too-shallow anterior chamber also affects unscrolling: the excessive contact of the scroll with the iris/cornea overwhelms the ability of tapping-induced fluid currents to induce unfurling [14,64–66]. Thus, too-deep/long and too-shallow/short eyes can both complicate DMEK-graft unscrolling, requiring the surgeon to generate an optimally shallow anterior chamber by adding or removing fluid during the unscrolling procedure. The effect of too-shallow/short eyes is supported by Hayashi et al., who reported that DMEK-graft unscrolling is often hindered in Asian eyes, which generally have shallow anterior chambers and shorter AXL [71]. Our study suggests the converse may also be true, namely, that too-deep/long eyes also complicate DMEK-graft unscrolling.
The role of ECL is speculative but likely. Solid red arrows indicate hypothetical graft failure-inducing mechanisms. The broken red arrow indicates the indirect AXL-mediated mechanism detected by posthoc univariable analyses. Green and blue arrows indicate how graft disease could generate frail (green arrow) or poorly functioning (blue arrow) endothelial cells. The brown and purple arrows indicate possible mechanisms by which graft detachment could promote graft ECL and vice versa. AC, anterior chamber; AXL, axial length; EC, endothelial cell; ECL, endothelial-cell loss.
Our hypothesis also states that graft-unscrolling difficulties induce ECL (Part 3), which leads to graft failure (Part 4). Part 3 is also supported by Hayashi et al.: they reported that too-shallow/short eyes (which associate with graft-unscrolling difficulty) display greater graft ECL [71]. Borroni et al. also observed that shorter AXL associates with more post-DMEK ECL [51]. Part 4 is supported by Çakmak et al., who found that shallow eyes have a 3-fold higher risk of graft failure after DMEK [72]. Multiple studies also report that unscrolling/positioning difficulties associate with ECL [10,11,13,20,73–75] and graft failure [75]. Thus, the literature indirectly supports the notion that not only too-shallow/short eyes but also eyes with very large AXL (≥25 mm) can promote graft-unscrolling difficulties, which induce ECL, which in turn promotes graft failure. Notably, this effect of too-large eyes may be compounded by the fact that it is difficult to generate an optimally shallow anterior chamber in such eyes [14].
Our finding suggests that eyes with AXL ≥ 25 mm should perhaps be treated with DSAEK rather than DMEK. Although the visual outcomes after DSAEK are not as good as that of DMEK, DSAEK is much less prone to graft detachment and easier to manage postoperatively [9]. Alternatively, we can consider using techniques that help induce shallow ACDs in post-vitrectomy eyes (which lack posterior pressure) and eyes with vitreous syneresis, previous PKP, or glaucoma shunts (which can be difficult to shallow). These techniques include denting the bulbar surface with a finger or surgical instrument [76] or temporarily placing cellulose sponges between the bulbar surface and the eyelid speculum in a hands-free manner [14]. Insertion of a transcleral infusion cannula to artificially increase vitreous pressure could also be considered. Moreover, it is important to ensure that patients with large anterior chambers remain supine after DMEK: Bennett et al. showed that while postoperative positioning has little effect on the amount of graft coverage by the endotamponade when the ACD is small, large ACDs associate with worse coverage, especially in pseudophakic eyes [77].
Long AXL also induces graft failure independently of graft-unscrolling difficulties.
Our multivariable analyses showed that longer AXL also directly induces graft failure (Fig 4, solid left-hand red arrow). The underlying mechanism could involve the larger volume of air/gas needed for endotamponade in eyes with longer AXL [61–63]: air is inherently toxic to the corneal endothelium [78,79], and the bubble itself may induce mechanical damage [80,81] or hamper endothelial-cell permeability or access to the aqueous humor and nutrients [82,83]. Since a larger bubble takes longer to disappear, this would extend bubble contact with the endothelium, thus potentially enhancing ECL that in turn promotes graft failure [22–24].
Graft-unscrolling/positioning difficulties could induce graft failure independently of AXL.
Our analyses also suggest that graft-unscrolling/positioning difficulty, the largest independent predictor of graft failure, plays an AXL-independent role in graft failure (Fig 4, middle solid red arrow). This may reflect the fact that this variable includes graft-positioning difficulties that require additional graft handling that exacerbates ECL. As mentioned above, multiple studies show that increased graft handling associates with greater ECL [10–12,20,75].
Note that we could not test whether long AXL or graft-unscrolling/positioning difficulties did in fact induce greater ECL, because the eyes whose DMEK graft eventually failed were edematous, which hindered postoperative ECD measurements.
Role of anterior chamber depth.
Although ACD correlates with AXL [61–63], we did not find that preoperative ACD associated with graft failure on univariable analysis. This may reflect the fact that (i) 48% of our eyes were pseudophakic at the time of DMEK, and (ii) preoperative ACD measurements with IOLMaster 700 are not reliable in pseudophakic eyes because the IOL and natural lens have different optical properties [84]. By contrast, IOLMaster measures preoperative AXL almost as well in pseudophakic eyes as in phakic eyes [85]. Univariable analysis of the 88 triple-DMEK eyes in our cohort did not show an association between ACD and graft failure, but this may reflect the small number of graft failures in this group (n = 7).
Relationship between major graft detachment and graft failure
We observed that major graft detachment that required rebubbling also strongly predicted DMEK-graft failure (OR=6.28). This association has been observed previously (S1 Table) [20]. Graft detachment likely reflects poor engagement of the wound-healing processes that integrate the donor Descemet membrane with the recipient stroma. Any factor that impairs the orderly and timely progression of this wound-healing cascade can thus result in graft detachment once the endotamponade wears off. These factors could include new edema or failure to clear existing edema after DMEK: such fluid disrupts the stromal microarchitecture and intercellular communications needed for proper wound healing [86–89]. A major cause of this edema may be graft ECL during surgery (Fig 4, purple arrow) that is generated, for example, by variables such as long AXL. Post-DMEK edema could also reflect preexisting endothelial-cell frailty (Fig 4, green arrow) or functional incompetence (Fig 4, blue arrow) that was not detected by the eye bank (Fig 3, dark grey oval).
Notably, rebubbling, the treatment for graft detachment, may itself promote ECL, thus worsening outcomes (Fig 4, brown arrow): multiple rebubbling associated with graft failure on our univariable analysis (p = 0.04) and other studies show that rebubbling, especially multiple rebubbling, associates with more ECL [21,32,40,90,91]. However, since DMEK grafts undergoing detachment may already have more ECL than attached grafts [92], it is unclear whether rebubbling does in fact induce additional ECL.
Graft detachment itself does not induce ECL: 2–5 weeks after complete detachment, DMEK grafts floating in the anterior chamber continue to have high ECDs [47]. Thus, the relationship between graft detachment and graft failure likely reflects factors that promote endothelial incompetence, which leads to wound-healing failure, graft detachment, and ultimately graft failure (Fig 4, bottom right red arrows).
Relationship between donor age and graft failure
We found that grafts from younger donors weakly predicted more DMEK-graft failure (OR=0.93, 95%CI = 0.88–0.99, p = 0.02), consistent with previous multivariable [93] and univariable [29] analyses showing that younger donor age predicts more graft detachment/rebubbling. Several studies suggest that this reflects the fact that older DMEK grafts are thicker and less elastic than younger grafts, which lead to looser scrolls [13,94]: it was proposed that these loose scrolls result in shorter graft-unscrolling times and less handling, which minimizes postoperative ECL [13] (Fig 4, curving top right red arrow). It should be noted, however, that graft-unscrolling/positioning difficulties did not associate with graft-donor age in our univariable analyses (Table 4). An alternative possibility is that graft scrolling inflicts detrimental ECL-inducing mechanical forces on the endothelial cells before transplantation (Fig. 3, straight top right red arrow). For example, the tight scrolling of young grafts (with endothelium on the outside [95]) could compress and rub the cells on the inside layers. These mechanical forces may both damage the cells physically and initiate detrimental mechanosignalling in the endothelial cells that induces their death [96].
However, it should be emphasized that the effect of donor age in our study was mild (OR=0.93) and the median ages of the patients who did and did not undergo graft failure were 70 and 75 years, respectively. Moreover, many other studies have not observed a link between graft-donor age and graft failure itself (S1 Table) [20,28,30,31,36,37] or its surrogates, namely, rebubbling, graft detachment [20,30,37,42,97–102], and ECL [10,11,18,54,93,97]. Thus, the clinical relevance of this finding may be limited.
Relationship between other variables and graft failure
We observed that women tended to undergo graft failure more often than men on both univariable (p = 0.09) and multivariable (OR=5.48, 95%CI = 0.76–39.58, p = 0.09) analysis. However, many other studies did not observe a relationship between patient sex and graft failure [31,20], rebubbling/graft detachment [20,41,69,93,98–100,103], or ECL [11,17,18,53,54,93,104]. The clinical relevance of this variable is likely to be low.
Patient age did not affect DMEK-graft failure, similar to several other studies [30,32]. This was also true for lens thickness. Similarly, preoperative visual acuity did not associate with DMEK-graft survival in our study or with graft detachment [69], rebubbling [19], or ECL [10,17,53,104] in other studies. Triple-DMEK did not increase graft failure in our or two other graft-failure studies [20,35] but one study found a univariable association (p = 0.03) [34] (S1 Table). Several studies [38,39,43,99,102,105] but not others [10,20,34,35,37,41,54,69,70,98,100,101,104,105–107] also reported that triple-DMEK associates with more rebubbling, graft detachment, and/or ECL. Interstudy variation in the inclusion of phakic-DMEK cases, which associate with less rebubbling than triple-DMEK and pseudophakic-DMEK [43,102,99], may partly explain these discrepancies.
Our univariable analysis and two other studies [27,28] found that using SF6 instead of air for endotamponade did not alter graft-failure rates (S1 Table). However, other studies suggest SF6 prevents graft detachment and rebubbling [28,68,108–112] while not altering ECL [18,53,113]. Further studies assessing the ability of SF6 to improve DMEK-graft survival are needed.
Study limitations
This study has several limitations. First, its retrospective design may have introduced selection and information bias, although the data were recorded prospectively. Second, as a monocentric study, it has limited generalizability. However, since all surgeries were performed by a single experienced surgeon, this may have minimized confounding related to variations in surgical technique. Third, all DMEKs were conducted as described by Melles [2], namely, with surgeon-prepared grafts rather than eyebank-prepared grafts, which are used in some countries. However, several studies have shown that graft preparation technique does not affect DMEK outcomes [38,114,115]. Fourth, the sample size was relatively small (n = 170). Fifth, the number of graft failure cases (n = 15) was small. Our study findings must be corroborated by larger scale studies. Sixth, 94% of our patients had FECD. Thus, it is unclear whether our findings can be extrapolated to other DMEK indications such as BK or regraft. Seventh, while ECL may play a central role in graft failure, we could not confirm that it participated in the mechanisms proposed in Fig 4 because postoperative ECD in failing grafts cannot be reliably measured by specular microscopy. Studies with more accurate methods such as confocal microscopy [116] are needed. Eighth, we did not measure other variables that could support the proposed mechanisms in Fig 4, including endotamponade duration and scroll width. Ninth, the individual contributions of graft-unscrolling difficulty and graft-positioning difficulty to graft failure could not be explored because most problematic cases had both. Tenth, the ability of multivariable analyses to detect factors that cause the outcome depends on the selected covariates, their inter-relationships, the study population, and measurement accuracy [67]. While we tested 20 covariates, we did not examine the contributions of other variables that may promote DMEK-graft failure, including surgeon learning curve [117], graft marking [118], graft storage conditions [93,119], donor diabetes [120,121], postoperative intraocular pressure changes [122], and glaucoma [123]. Thus, our multivariable analysis results, including the effect of long AXL, require validation by other groups.
Conclusions
Our multivariable analysis showed that AXL, which has been rarely studied in DMEK, predicted graft failure. Specifically, AXL ≥ 25 mm predicted significantly more graft failure than shorter AXL. Thus, if a patient has AXL ≥ 25 mm, it may be necessary to consider using DSAEK, which has worse visual outcomes than DMEK but is easier to conduct. Alternatively, mitigating surgical approaches should be taken to ensure adequate anterior-chamber shallowing during DMEK in these eyes. Additional studies are needed to confirm our findings and determine the relative merits of DSAEK and DMEK in patients with high myopia. DMEK-graft failure may also be reduced by minimizing graft-unscrolling/positioning difficulties. Assiduously treating major graft detachment with rebubbling could also improve graft survival, although it is also possible that rebubbling, especially multiple rebubbling, inflicts counterproductive ECL. Studies with techniques that can measure ECD in edematous grafts are needed to determine the pros and cons of DMEK-graft rebubbling.
Supporting information
S1 Table. Summary of the literature searching for risk factors for graft failure after DMEK.
https://doi.org/10.1371/journal.pone.0352687.s005
(DOCX)
S2 Table. Multivariable analysis of factors that predict graft failure, with axial length expressed as a continuous variable (n = 170).
https://doi.org/10.1371/journal.pone.0352687.s001
(DOCX)
S3 Table. Multivariable analysis of factors that predict graft failure in all consecutive eyes before exclusions (n = 188).
https://doi.org/10.1371/journal.pone.0352687.s002
(DOCX)
S4 Table. Posthoc multivariable analysis of factors that predict graft failure with axial length excluded (n = 170).
https://doi.org/10.1371/journal.pone.0352687.s003
(DOCX)
S5 Table. Posthoc multivariable analysis of factors that predict graft failure with graft-unscrolling/positinoning difficulty excluded (n = 170).
https://doi.org/10.1371/journal.pone.0352687.s004
(DOCX)
References
- 1. Price MO, Gupta P, Lass J, Price FW. EK (DLEK, DSEK, DMEK): new frontier in cornea surgery. Annu Rev Vis Sci. 2017;3:69–90.
- 2. Melles GRJ, Ong TS, Ververs B, van der Wees J. Descemet membrane endothelial keratoplasty (DMEK). Cornea. 2006;25(8):987–90. pmid:17102683
- 3. Price MO, Mehta JS, Jurkunas UV, Price FW Jr. Corneal endothelial dysfunction: evolving understanding and treatment options. Prog Retin Eye Res. 2021;82:100904. pmid:32977001
- 4. Ong Tone S, Kocaba V, Böhm M, Wylegala A, White TL, Jurkunas UV. Fuchs endothelial corneal dystrophy: the vicious cycle of Fuchs pathogenesis. Prog Retin Eye Res. 2021;80:100863. pmid:32438095
- 5. Malleron V, Bloch F, Zevering Y, Vermion J-C, Semler-Collery A, Goetz C, et al. Evolution of corneal transplantation techniques and their indications in a French corneal transplant unit in 2000-2020. PLoS One. 2022;17(4):e0263686. pmid:35486609
- 6. Price MO, Gorovoy M, Benetz BA, Price FW Jr, Menegay HJ, Debanne SM, et al. Descemet’s stripping automated endothelial keratoplasty outcomes compared with penetrating keratoplasty from the Cornea Donor Study. Ophthalmology. 2010;117(3):438–44. pmid:20031230
- 7. Heinzelmann S, Böhringer D, Eberwein P, Reinhard T, Maier P. Outcomes of Descemet membrane endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty and penetrating keratoplasty from a single centre study. Graefes Arch Clin Exp Ophthalmol. 2016;254(3):515–22. pmid:26743748
- 8. Dunker SL, Dickman MM, Wisse RPL, Nobacht S, Wijdh RHJ, Bartels MC. Descemet membrane endothelial keratoplasty versus ultrathin descemet stripping automated endothelial keratoplasty: a multicenter randomized controlled clinical trial. Ophthalmology. 2020;127:1152–9.
- 9. Marques RE, Guerra PS, Sousa DC, Gonçalves AI, Quintas AM, Rodrigues W. DMEK versus DSAEK for Fuchs’ endothelial dystrophy: A meta-analysis. Eur J Ophthalmol. 2019;29(1):15–22. pmid:29661044
- 10. Chaussard D, Bloch F, Elnar AA, Zevering Y, Vermion J-C, Moskwa R, et al. Identification of the preoperative and perioperative factors that predict postoperative endothelial cell density after Descemet membrane endothelial keratoplasty: A retrospective cohort study. PLoS One. 2022;17(2):e0264401. pmid:35202443
- 11. Oellerich S, Ham L, Frank LE, Gorges S, Bourgonje VJA, Baydoun L, et al. Parameters associated with endothelial cell density variability after descemet membrane endothelial keratoplasty. Am J Ophthalmol. 2020;211:22–30. pmid:31647928
- 12. Maier A-KB, Gundlach E, Schroeter J, Klamann MKJ, Gonnermann J, Riechardt AI, et al. Influence of the difficulty of graft unfolding and attachment on the outcome in Descemet membrane endothelial keratoplasty. Graefes Arch Clin Exp Ophthalmol. 2015;253(6):895–900. pmid:25631845
- 13. Heinzelmann S, Hüther S, Böhringer D, Eberwein P, Reinhard T, Maier P. Influence of donor characteristics on descemet membrane endothelial keratoplasty. Cornea. 2014;37:1347–50.
- 14. Kam Y, Kigin M, Rosenberg ED, Blitzer A, Sales CS. Chamber shallowing technique for challenging DMEK cases: Tucking cellulose spears under the speculum to augment posterior pressure. Indian J Ophthalmol. 2024;72(Suppl 3):S533–5. pmid:38317304
- 15. Baydoun L, Ham L, Borderie V, Dapena I, Hou J, Frank LE, et al. Endothelial Survival after descemet membrane endothelial keratoplasty: effect of surgical indication and graft adherence status. JAMA Ophthalmol. 2015;133(11):1277–85. pmid:26355238
- 16. Gerber-Hollbach N, Baydoun L, López EF, Frank LE, Dapena I, Liarakos VS, et al. Clinical outcome of rebubbling for graft detachment after descemet membrane endothelial keratoplasty. Cornea. 2017;36(7):771–6. pmid:28437276
- 17. Peraza-Nieves J, Baydoun L, Dapena I, Ilyas A, Frank LE, Luceri S, et al. Two-year clinical outcome of 500 consecutive cases undergoing descemet membrane endothelial keratoplasty. Cornea. 2017;36(6):655–60. pmid:28410548
- 18. Hayashi T, Schrittenlocher S, Siebelmann S, Le VNH, Matthaei M, Franklin J, et al. Risk factors for endothelial cell loss after Descemet membrane endothelial keratoplasty (DMEK). Sci Rep. 2020;10(1):11086. pmid:32632151
- 19. Lazaridis A, Fydanaki O, Giallouros E, Georgalas I, Kymionis G, Sekundo W, et al. Recovery of Corneal Clarity After DMEK Followed by Rebubbling Versus Uneventful DMEK. Cornea. 2018;37(7):840–7. pmid:29672430
- 20. Dunker S, Winkens B, van den Biggelaar F, Nuijts R, Kruit PJ, Dickman M, et al. Rebubbling and graft failure in Descemet membrane endothelial keratoplasty: a prospective Dutch registry study. Br J Ophthalmol. 2023;107(1):17–23. pmid:33597192
- 21. Tapley JL, Hill JR, Bauer AJ, Straiko MMW, Straiko MD, Terry MA. Rate of endothelial cell loss and graft survival in descemet membrane endothelial keratoplasty in eyes requiring a rebubble. Cornea. 2023;42(8):934–9. pmid:36731078
- 22. Bichet P, Moskwa R, Goetz C, Zevering Y, Vermion J-C, Perone J-M. Five-year clinical outcomes of 107 consecutive DMEK surgeries. PLoS One. 2023;18(12):e0295434. pmid:38127965
- 23. Viola P, Neri E, Occhipinti T, Parekh M, Cian R, Ponzin D, et al. Predicting long-term endothelial cell loss after preloaded descemet membrane endothelial keratoplasty in fuchs’ endothelial corneal dystrophy: a mathematical model. J Clin Med. 2024;13(3):877. pmid:38337570
- 24. Writing Committee for the Cornea Donor Study Research Group, Sugar A, Gal RL, Kollman C, Raghinaru D, Dontchev M, et al. Factors associated with corneal graft survival in the cornea donor study. JAMA Ophthalmol. 2015;133(3):246–54. pmid:25322173
- 25. Deng SX, Lee WB, Hammersmith KM, Kuo AN, Li JY, Shen JF, et al. Descemet membrane endothelial keratoplasty: safety and outcomes: a report by the american academy of ophthalmology. Ophthalmology. 2018;125:295–310.
- 26. Maier A-KB, Pilger D, Gundlach E, Winterhalter S, Torun N, Dietrich-Ntoukas T. Graft failure rate and complications after Descemet membrane endothelial keratoplasty in eyes with pre-existing glaucoma. Graefes Arch Clin Exp Ophthalmol. 2023;261(2):467–76. pmid:36040539
- 27. Rickmann A, Szurman P, Jung S, Boden KT, Wahl S, Haus A, et al. Impact of 10% SF6 gas compared to 100% air tamponade in descemet’s membrane endothelial keratoplasty. Curr Eye Res. 2018;43(4):482–6. pmid:29377740
- 28. Schaub F, Enders P, Snijders K, Schrittenlocher S, Siebelmann S, Heindl LM, et al. One-year outcome after Descemet membrane endothelial keratoplasty (DMEK) comparing sulfur hexafluoride (SF6) 20% versus 100% air for anterior chamber tamponade. Br J Ophthalmol. 2017;101(7):902–8. pmid:27836829
- 29. Schaub F, Enders P, Zachewicz J, Heindl LM, Stanzel TP, Cursiefen C. Impact of donor age on Descemet membrane endothelial keratoplasty outcome: evaluation of donors aged 17–55 years. Am J Ophthalmol. 2016;170:119–27.
- 30. TUTAŞ GÜNAYDIN N, TANYILDIZ B. Donor and recipient characteristics associated with rebubbling rate, endothelial cell loss, and graft failure in primary descemet membrane endothelial keratoplasty. J Heal Sci Med. 2022;5:1461–7.
- 31. Fliotsos MJ, Campbell JA, Li X, Engstrom MB, Stoeger CG, McClory C, et al. Trends in early graft failure leading to regrafting after endothelial keratoplasty in the United States. Cornea. 2022;41(7):833–9. pmid:34369391
- 32. Gundlach E, Pilger D, Dietrich-Ntoukas T, Joussen AM, Torun N, Maier A-KB. Impact of re-bubbling after descemet membrane endothelial keratoplasty on long-term results. Curr Eye Res. 2021;46(6):784–8. pmid:33179517
- 33. Achiron A, Nahum Y, Tiosano A, Shehadeh Mashor R, Tuuminen R, Elbaz U, et al. Descemet membrane endothelial keratoplasty outcomes between young and old graft recipients. Curr Eye Res. 2021;46(10):1460–6. pmid:33840319
- 34. Fajardo-Sanchez J, de Benito-Llopis L. Clinical outcomes of descemet membrane endothelial keratoplasty in pseudophakic eyes compared with triple-DMEK at 1-Year Follow-up. Cornea. 2021;40(4):420–4. pmid:33369940
- 35. Rickmann A, Andres C, Boden K, Wahl S, Szurman P. Analysis of different types of anesthesia in descemet membrane endothelial keratoplasty. Int Ophthalmol. 2020;40(3):541–5. pmid:31768812
- 36. Schaub F, Collmer M, Schrittenlocher S, Bachmann BO, Cursiefen C, Hos D. Outcome of descemet membrane endothelial keratoplasty using corneas from donors ≥80 years of age. Am J Ophthalmol. 2020;211:200–6. pmid:31837315
- 37. Godin MR, Boehlke CS, Kim T, Gupta PK. Influence of lens status on outcomes of descemet membrane endothelial keratoplasty. Cornea. 2019;38:409–12.
- 38. Romano V, Kazaili A, Pagano L, Gadhvi KA, Titley M, Steger B, et al. Eye bank versus surgeon prepared DMEK tissues: influence on adhesion and re-bubbling rate. Br J Ophthalmol. 2022;106(2):177–83. pmid:33127828
- 39. Kladny A-MS, Zander DB, Lieberum J-L, Glatz A, Brandi-Dohrn F, Reinhard T, et al. Graft detachment after descemet membrane endothelial keratoplasty with and without cataract surgery. Ophthalmol Sci. 2022;2(4):100194. pmid:36531572
- 40. Siebelmann S, Kolb K, Scholz P, Matthaei M, Franklin J, Händel A, et al. The Cologne rebubbling study: a reappraisal of 624 rebubblings after Descemet membrane endothelial keratoplasty. Br J Ophthalmol. 2021;105(8):1082–6. pmid:32816807
- 41. Hussien AMRM, Elmassry A, Ghaith AA, Goweida MBB. Descemet’s membrane endothelial keratoplasty and phacoemulsification: combined versus sequential surgery. J Curr Ophthalmol. 2021;33(3):277–84. pmid:34765815
- 42. Hill JR, Chen SY, Bauer AJ, Straiko MMW, Sanchez PJ, Straiko MD, et al. Younger donor tissue in Descemet membrane endothelial keratoplasty surgery: clinical outcomes. Cornea. 2021;40:1024–30.
- 43. Moshiri I, Karimi-Golkar D, Schrittenlocher S, Cursiefen C, Bachmann B. Outcomes of pseudophakic, phakic, and triple DMEK. Cornea. 2021.
- 44. Gurnani B, Kaur K, Lalgudi VG, Tripathy K. Risk Factors for descemet membrane endothelial keratoplasty rejection: current perspectives-systematic review. Clin Ophthalmol. 2023;17:421–40.
- 45. Schmidt I, Schlötzer-Schrehardt U, Langenbucher A, Eppig T, Hager T, Zimpfer A, et al. Ultrastructural findings in graft failure after Descemet membrane endothelial keratoplasty (DMEK) and new triple procedure. Medicine (Baltimore). 2019;98(19):e15493. pmid:31083187
- 46. Ćirković A, Schlötzer-Schrehardt U, Weller JM, Kruse FE, Tourtas T. Clinical and ultrastructural characteristics of graft failure in DMEK: 1-year results after repeat DMEK. Cornea. 2015;34(1):11–7. pmid:25379869
- 47. Ham L, van der Wees J, Melles GRJ. Causes of primary donor failure in descemet membrane endothelial keratoplasty. Am J Ophthalmol. 2008;145(4):639–44. pmid:18255046
- 48. Weller JM, Schlötzer-Schrehardt U, Tourtas T, Kruse FE. Influence of ultrastructural corneal graft abnormalities on the outcome of descemet membrane endothelial keratoplasty. Am J Ophthalmol. 2016;169:58–67. pmid:27318075
- 49. Droutsas K, Alexopoulos P, Giachos I, Giallouros E, Sekundo W, Lazaridis A. Secondary DMEK following failed primary DMEK. Int Ophthalmol. 2021;41(10):3287–93. pmid:34076784
- 50. Gómez-Benlloch A, Montesel A, Pareja-Aricò L, Mingo-Botín D, Michael R, Barraquer RI, et al. Causes of corneal transplant failure: a multicentric study. Acta Ophthalmol. 2021;99(6):e922–8. pmid:33421330
- 51. Borroni D, Ferronato M, Krumina Z, Parekh M. Importance of axial length and functional corneal endothelial cells in descemet membrane endothelial keratoplasty. Cornea. 2017;36(12):e35–6. pmid:29045313
- 52. Siggel R, Heindl LM, Cursiefen C. Descemet membrane endothelial keratoplasty (DMEK) in phakic eyes with shallow anterior chamber. Graefes Arch Clin Exp Ophthalmol. 2015;253(5):817–9. pmid:25408423
- 53. Inoda S, Hayashi T, Takahashi H, Oyakawa I, Yokogawa H, Kobayashi A, et al. Factors associated with endothelial cell density loss post Descemet membrane endothelial keratoplasty for bullous keratopathy in Asia. PLoS One. 2020;15(6):e0234202. pmid:32525919
- 54. Lekhanont K, Pisitpayat P, Cheewaruangroj N, Jongkhajornpong P, Nonpassopon M, Anothaisintawee T. Outcomes of descemet membrane endothelial keratoplasty in bangkok, thailand. Clin Ophthalmol. 2021;15:2239–51.
- 55. Kim CY, Yoon CH, Kim MK. Risk factors for early graft detachment requiring rebubbling in Descemet membrane endothelial keratoplasty with imported pre-cut donor tissues. Front Med (Lausanne). 2024;11:1266049. pmid:38390568
- 56. Diab RA, Zarei-ghanavati M, Bardan AS, Vasquez-perez A, Liu G. Preferred practices of Descemet’s membrane endothelial keratoplasty (DMEK) surgeons in the UK: A national survey. J EuCornea. 2022;11:1–7.
- 57. Livny E, Groeneveld-van Beek EA, Lie JT, Mangundap KM, Bruinsma M, Birbal RS. Minimizing graft preparation failure in Descemet membrane endothelial keratoplasty. Cornea. 2017;36:1452–7.
- 58. Romano D, Shimizu T, Kobayashi A, Yamagami S, Romano V, Hayashi T. Descemet membrane endothelial keratoplasty in aphakic, aniridic, and vitrectomized eyes: a review. Cornea. 2024.
- 59. Perone J-M, Goetz C, Zaidi M, Lhuillier L. Supracapsular phacoemulsification: description of the “Garde à vous” technique and comparative clinical results. J Fr Ophtalmol. 2019;42(6):597–602. pmid:31097313
- 60. Augustin VA, Son H-S, Yildirim TM, Meis J, Łabuz G, Auffarth GU, et al. Refractive outcomes after DMEK: meta-analysis. J Cataract Refract Surg. 2023;49(9):982–7. pmid:37144644
- 61. Chang JSM, Lau SYF. Correlation between axial length and anterior chamber depth in normal eyes, long eyes, and extremely long eyes. Asia Pac J Ophthalmol (Phila). 2012;1(4):213–5. pmid:26107475
- 62. Tanaka T, Nishitsuka K, Obata H. Correlation of ocular biometry with axial length in elderly Japanese. Clin Ophthalmol. 2024;18:351–60. pmid:38332905
- 63. Jivrajka R, Shammas MC, Boenzi T, Swearingen M, Shammas HJ. Variability of axial length, anterior chamber depth, and lens thickness in the cataractous eye. J Cataract Refract Surg. 2008;34(2):289–94. pmid:18242456
- 64. Kruse FE, Laaser K, Cursiefen C, Heindl LM, Schlötzer-Schrehardt U, Riss S, et al. A stepwise approach to donor preparation and insertion increases safety and outcome of Descemet membrane endothelial keratoplasty. Cornea. 2011;30(5):580–7. pmid:21598430
- 65.
Shah KJ, Straiko MD, Greiner MA. Surgical technique for DMEK. Endothelial Keratoplasty. Elsevier. 2016. p. 1468–79.
- 66. Brennan K. DMEK success: maintaining the graft. Review of Ophthalmology. 2023.
- 67. Brotman DJ, Walker E, Lauer MS, O’Brien RG. In search of fewer independent risk factors. Arch Intern Med. 2005;165: 138–45.
- 68. Siebelmann S, Ramos SL, Scholz P, Matthaei M, Schrittenlocher S, Heindl LM. Graft detachment pattern after Descemet membrane endothelial keratoplasty comparing air versus 20% SF 6 tamponade. Cornea. 2018;37:834–9.
- 69. Brockmann T, Brockmann C, Maier A-K, Schroeter J, Pleyer U, Bertelmann E, et al. Clinicopathology of graft detachment after Descemet’s membrane endothelial keratoplasty. Acta Ophthalmol. 2014;92(7):e556-61. pmid:24725459
- 70. Chaurasia S, Price FW Jr, Gunderson L, Price MO. Descemet’s membrane endothelial keratoplasty: clinical results of single versus triple procedures (combined with cataract surgery). Ophthalmology. 2014;121(2):454–8. pmid:24252821
- 71. Hayashi T, Oyakawa I, Kato N. Techniques for learning descemet membrane endothelial keratoplasty for eyes of Asian patients with shallow anterior chamber. Cornea. 2017;36(3):390–3. pmid:28002113
- 72. Çakmak S, Kirgiz A, Yildirim Y, Taşkoparan S, Genç S, Ağca A. The effect of anterior segment parameters on surgical success of Descemet membrane endothelial keratoplasty: a prospective study. Int Ophthalmol. 2023;43(1):197–205. pmid:35810243
- 73. Maier A-KB, Gundlach E, Schroeter J, Klamann MKJ, Gonnermann J, Riechardt AI, et al. Influence of the difficulty of graft unfolding and attachment on the outcome in Descemet membrane endothelial keratoplasty. Graefes Arch Clin Exp Ophthalmol. 2015;253(6):895–900. pmid:25631845
- 74. Röck T, Bramkamp M, Bartz-Schmidt KU, Röck D, Yörük E. Causes that influence the detachment rate after Descemet membrane endothelial keratoplasty. Graefes Arch Clin Exp Ophthalmol. 2015;253(12):2217–22. pmid:26216795
- 75. Fu L, Hollick EJ. Rebubbling and graft detachment in Descemet membrane endothelial keratoplasty using a standardised protocol. Eye (Lond). 2023;37(12):2494–8. pmid:36522529
- 76. Yoeruek E, Bayyoud T, Hofmann J, Bartz-Schmidt K-U. Novel maneuver facilitating Descemet membrane unfolding in the anterior chamber. Cornea. 2013;32(3):370–3. pmid:22820605
- 77. Bennett VG, Alberti M, Quadrio M, Pralits JO. Optimization of patient positioning for improved healing after corneal transplantation. J Biomech. 2023;150:111510. pmid:36863199
- 78. Lee DA, Wilson MR, Yoshizumi MO, Hall M. The ocular effects of gases when injected into the anterior chamber of rabbit eyes. Arch Ophthalmol. 1991;109(4):571–5. pmid:2012561
- 79. Hesse M, Kuerten D, Walter P, Plange N, Johnen S, Fuest M. The effect of air, SF6 and C3F8 on immortalized human corneal endothelial cells. Acta Ophthalmol. 2017;95(4):e284–90. pmid:27595913
- 80. Hong A, Caldwell MC, Kuo AN, Afshari NA. Air bubble-associated endothelial trauma in descemet stripping automated endothelial keratoplasty. Am J Ophthalmol. 2009;148(2):256–9. pmid:19426961
- 81. Kim EK, Cristol SM, Geroski DH, McCarey BE, Edelhauser HF. Corneal endothelial damage by air bubbles during phacoemulsification. Arch Ophthalmol. 1997;115(1):81–8. pmid:9006430
- 82. Green K, Cheeks L, Stewart DA, Norman BC. Intraocular gas effects on corneal endothelial permeability. Lens Eye Toxic Res. 1992;9(2):85–91. pmid:1375836
- 83. Olson RJ. Air and the corneal endothelium: an in vivo specular microscopy study in cats. Arch Ophthalmol. 1980;98(7):1283–4. pmid:7396785
- 84. Su P-F, Lo AY, Hu C-Y, Chang S-W. Anterior chamber depth measurement in phakic and pseudophakic eyes. Optom Vis Sci. 2008;85(12):1193–200. pmid:19050474
- 85. Chang S-W, Yu C-Y, Chen DP. Comparison of intraocular lens power calculation by the IOLMaster in phakic and eyes with hydrophobic acrylic lenses. Ophthalmology. 2009;116(7):1336–42. pmid:19427697
- 86. Mohan RR, Kempuraj D, D’Souza S, Ghosh A. Corneal stromal repair and regeneration. Prog Retin Eye Res. 2022;91:101090. pmid:35649962
- 87. Barrientez B, Nicholas SE, Whelchel A, Sharif R, Hjortdal J, Karamichos D. Corneal injury: clinical and molecular aspects. Exp Eye Res. 2019;186:107709. pmid:31238077
- 88. Kamil S, Mohan RR. Corneal stromal wound healing: major regulators and therapeutic targets. Ocul Surf. 2021;19:290–306. pmid:33127599
- 89. Shadmani A, Wu AY. Navigating the path to corneal healing success and challenges: a comprehensive overview. Eye (Lond). 2025;39(6):1047–55. pmid:39939391
- 90. Spaniol K, Hellmich M, Borgardts K, Girbardt C, Maier P, Reinhard T, et al. DMEK outcome after one year - Results from a large multicenter study in Germany. Acta Ophthalmol. 2023;101(2):e215–25. pmid:36178238
- 91. Feng MT, Price MO, Miller JM, Price FW Jr. Air reinjection and endothelial cell density in Descemet membrane endothelial keratoplasty: five-year follow-up. J Cataract Refract Surg. 2014;40(7):1116–21. pmid:24957432
- 92. Miron A, Bruinsma M, Ham L, Schaal S-C, Baydoun L, Dapena I, et al. In vivo endothelial cell density decline in the early postoperative phase after descemet membrane endothelial keratoplasty. Cornea. 2018;37(6):673–7. pmid:29737973
- 93. Rodríguez-Calvo de Mora M, Groeneveld-van Beek EA, Frank LE, van der Wees J, Oellerich S, Bruinsma M, et al. Association between graft storage time and donor age with endothelial cell density and graft adherence after descemet membrane endothelial keratoplasty. JAMA Ophthalmol. 2016;134(1):91–4. pmid:26562408
- 94. Bennett A, Mahmoud S, Drury D, Cavanagh HD, McCulley JP, Petroll WM, et al. Impact of donor age on corneal endothelium-descemet membrane layer scroll formation. Eye Contact Lens. 2015;41(4):236–9. pmid:25603436
- 95. Gupta N, Kumar A, Vaddavalli PK, Mahapatra NR, Varshney A, Ghosh P. Efficient reduction of the scrolling of Descemet membrane endothelial keratoplasty grafts by engineering the medium. Acta Biomater. 2023;171:239–48. pmid:37739249
- 96. Ali M, Raghunathan V, Li JY, Murphy CJ, Thomasy SM. Biomechanical relationships between the corneal endothelium and Descemet’s membrane. Exp Eye Res. 2016;152:57–70. pmid:27639516
- 97. Straiko MD, Bauer AJ, Straiko MMW, Potts LB, Chen S-Y, Tran KD, et al. Donor DMEK tissue characteristics: association with rebubble rate and 6-month endothelial cell loss. Cornea. 2020;39(10):1267–73. pmid:32558729
- 98. Heinzelmann S, Böhringer D, Haverkamp C, Lapp T, Eberwein P, Reinhard T. Influence of postoperative intraocular pressure on graft detachment after Descemet membrane endothelial keratoplasty. Cornea. 2018;37:1347–50.
- 99. Leon P, Parekh M, Nahum Y, Mimouni M, Giannaccare G, Sapigni L, et al. Factors associated with early graft detachment in primary descemet membrane endothelial keratoplasty. Am J Ophthalmol. 2018;187:117–24. pmid:29339064
- 100. Mechels KB, Greenwood MD, Sudhagoni RG, Berdahl JP. Influences on rebubble rate in Descemet’s membrane endothelial keratoplasty. Clin Ophthalmol. 2017;11:2139–44. pmid:29255344
- 101. Maier A-KB, Gundlach E, Pilger D, Rübsam A, Klamann MKJ, Gonnermann J, et al. Rate and localization of graft detachment in descemet membrane endothelial keratoplasty. Cornea. 2016;35(3):308–12. pmid:26764881
- 102. Gundlach E, Maier AKB, Tsangaridou MA, Riechardt AI, Brockmann T, Bertelmann E. DMEK in phakic eyes: targeted therapy or highway to cataract surgery? Graefe’s Arch Clin Exp Ophthalmol. 2015;253:909–14.
- 103. Yuda K, Kato N, Takahashi H, Shimizu T, Oyakawa I, Matsuzawa A, et al. Effect of Graft shift direction on graft detachment and endothelial cell survival after descemet membrane endothelial keratoplasty. Cornea. 2019;38(8):970–5. pmid:31135493
- 104. Oellerich S, Baydoun L, Peraza-Nieves J, Ilyas A, Frank L, Binder PS, et al. Multicenter study of 6-month clinical outcomes after descemet membrane endothelial keratoplasty. Cornea. 2017;36(12):1467–76. pmid:28957979
- 105. Shahnazaryan D, Hajjar Sese A, Hollick EJ. Endothelial cell loss after descemet’s membrane endothelial keratoplasty for fuchs’ endothelial dystrophy: DMEK compared to triple DMEK. Am J Ophthalmol. 2020;218:1–6. pmid:32437670
- 106. Schaub F, Pohl L, Enders P, Adler W, Bachmann BO, Cursiefen C, et al. Impact of corneal donor lens status on two-year course and outcome of Descemet membrane endothelial keratoplasty (DMEK). Graefes Arch Clin Exp Ophthalmol. 2017;255(12):2407–14. pmid:29034411
- 107. Semler-Collery A, Bloch F, Hayek G, Goetz C, Perone JM. Comparison of triple-DMEK to pseudophakic-DMEK: a cohort study of 95 eyes. PLoS One. 2022;17(5):e0267940. pmid:35551322
- 108. Güell JL, Morral M, Gris O, Elies D, Manero F. Comparison of sulfur hexafluoride 20% versus air tamponade in descemet membrane endothelial keratoplasty presented in part at: fifth annual EUCornea Congress, September 2014, London, United Kingdom. Ophthalmology. 2015;122: 1757–1764. 10.1016/j.ophtha.2015.05.013
- 109. Botsford B, Vedana G, Cope L, Yiu SC, Jun AS. Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK). Arq Bras Oftalmol. 2016;79(5):299–302. pmid:27982207
- 110. von Marchtaler PV, Weller JM, Kruse FE, Tourtas T. Air versus sulfur hexafluoride gas tamponade in descemet membrane endothelial keratoplasty: a fellow eye comparison. Cornea. 2018;37(1):15–9. pmid:29040116
- 111. Ampazas P, Droutsas K, Giallouros E, Schroeder FM, Sekundo W. Comparison of 5% sulfur hexafluoride versus 100% air tamponade in descemet membrane endothelial keratoplasty. Cornea. 2017;36:1189–94.
- 112. Karaca EE, Işık FD, Özek D, Evren Kemer Ö. Comparison of efficacy of three gases for anterior chamber tamponade in Descemet’s membrane endothelial keratoplasty. J Fr Ophtalmol. 2024;47(2):103979. pmid:37858497
- 113. Esteves Marques R, Silva Guerra P, Cordeiro Sousa D, Pinto Ferreira N, Inês Gonçalves A, Miguel Quintas A. Sulfur hexafluoride 20% versus air 100% for anterior chamber tamponade in DMEK: a meta-analysis. Cornea. 2018;37:691–7.
- 114. Koechel D, Hofmann N, Unterlauft JD, Wiedemann P, Girbardt C. Descemet membrane endothelial keratoplasty (DMEK): clinical results of precut versus surgeon-cut grafts. Graefes Arch Clin Exp Ophthalmol. 2021;259(1):113–9. pmid:32845370
- 115. Regnier M, Auxenfans C, Maucort-Boulch D, Marty A-S, Damour O, Burillon C, et al. Eye bank prepared versus surgeon cut endothelial graft tissue for Descemet membrane endothelial keratoplasty: an observational study. Medicine (Baltimore). 2017;96(19):e6885. pmid:28489792
- 116. Ong Tone S, Jurkunas U. Imaging the corneal endothelium in fuchs corneal endothelial dystrophy. Semin Ophthalmol. 2019;34(4):340–6. pmid:31215821
- 117. Droutsas K, Giallouros E, Melles GRJ, Chatzistefanou K, Sekundo W. Descemet membrane endothelial keratoplasty: learning curve of a single surgeon. Cornea. 2013;32(8):1075–9. pmid:23635857
- 118. Veldman PB, Dye PK, Holiman JD, Mayko ZM, Sáles CS, Straiko MD, et al. The S-stamp in descemet membrane endothelial keratoplasty safely eliminates upside-down graft implantation. Ophthalmology. 2016;123(1):161–4. pmid:26439215
- 119. Birbal RS, Ni Dhubhghaill S, Bourgonje VJA, Hanko J, Ham L, Jager MJ, et al. Five-year graft survival and clinical outcomes of 500 consecutive cases after descemet membrane endothelial keratoplasty. Cornea. 2020;39(3):290–7. pmid:31478948
- 120. Greiner MA, Rixen JJ, Wagoner MD, Schmidt GA, Stoeger CG, Straiko MD, et al. Diabetes mellitus increases risk of unsuccessful graft preparation in Descemet membrane endothelial keratoplasty: a multicenter study. Cornea. 2014;33(11):1129–33. pmid:25222000
- 121. Price MO, Lisek M, Feng MT, Price FW. Effect of donor and recipient diabetes status on Descemet membrane endothelial keratoplasty adherence and survival. Cornea. 2017;36:1184–8.
- 122. Xie Z-J, Wu Q-Y, Qu J-H, Lin J-Y, Hong J. Impact of postoperative intraocular pressure elevation on graft endothelial cells in non-preexisting glaucoma eyes undergoing descemet membrane endothelial keratoplasty: a cohort study. BMC Ophthalmol. 2024;24(1):460. pmid:39434062
- 123. Sorkin N, Mimouni M, Kisilevsky E, Boutin T, Cohen E, Trinh T, et al. Four-year survival of descemet membrane endothelial keratoplasty in patients with previous glaucoma surgery. Am J Ophthalmol. 2020;218:7–16. pmid:32446739