Translation of Chinese version of the measure of audiologic rehabilitation self-efficacy for hearing aids and the self-efficacy among hearing aid users in China: Application of the questionnaire

  • Jiamei Chen ,

    Contributed equally to this work with: Jiamei Chen, Ying Shen

    Roles Data curation, Formal analysis, Investigation, Validation, Writing – original draft, Writing – review & editing

    Affiliations Department of Otolaryngology–Head and Neck Surgery, Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Shanghai, China, Shanghai Key Laboratory of Sleep Disordered Breathing, Shanghai, China

  • Ying Shen ,

    Contributed equally to this work with: Jiamei Chen, Ying Shen

    Roles Data curation, Formal analysis, Investigation

    Affiliation Department of Otolaryngology, Shanghai Tenth People’s Hospital, School of Medicine, Tongji University, Shanghai, China

  • Quanran Lin,

    Roles Formal analysis, Investigation

    Affiliation School of Medical Technology and Information Engineering, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China

  • Yanmei Feng ,

    Roles Conceptualization, Funding acquisition, Methodology, Project administration, Resources, Supervision, Validation, Writing – original draft, Writing – review & editing

    feng.yanmei@126.com (YF); lky0110@126.com (HL)

    Affiliations Department of Otolaryngology–Head and Neck Surgery, Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Shanghai, China, Shanghai Key Laboratory of Sleep Disordered Breathing, Shanghai, China

  • Hui Li

    Roles Conceptualization, Funding acquisition, Project administration, Resources, Supervision, Validation, Writing – review & editing

    feng.yanmei@126.com (YF); lky0110@126.com (HL)

    Affiliation Department of Ophthalmology, Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Shanghai, China

Abstract

Objectives

To evaluate reliability and validity of the Chinese version of the Measure of Audiologic Rehabilitation Self-Efficacy for Hearing Aids (C-MARS-HA) and to analyze self-efficacy of Chinese hearing aid users.

Design

The Brislin translation model was strictly adopted to modify the C-MARS-HA. Participants included 134 hearing aid users aged 20–98. Hearing aid users were surveyed through questionnaire interviews regarding self-efficacy and overall satisfaction with hearing aids. Reliability and validity of the questionnaires were analyzed. Descriptive statistical and correlation analyses were conducted on the total score and four factors of the C-MARS-HA and overall satisfaction.

Results

In reliability analysis, Cronbach’ s α, Spearman-Brown, and Guttman split-half coefficients of the overall and four factors were all greater than 0.6, indicating that C-MARS-HA has acceptable reliability. In validity analysis, C-MARS-HA consisted of 24 items across 4 factors (basic handling, aided listening, adjustment and advanced handling) and had acceptable content validity. Exploratory factor analysis yielded with a four-factor solution, explaining more than 40% of the total variance and the loading coefficient for each of the 24 items was above 0.4, indicating that C-MARS-HA had good construct validity.

Average scores for basic handling and adjustment were at least 80%, whereas average scores for aided listening, advanced handling, and total scores were less than 80%. A total of 65.67% of users had an overall satisfaction rate of 80%. A significant positive correlation (p < 0.001) was found between the total score of the questionnaire, the scores of the four factors, and overall satisfaction.

Conclusions

The reliability and validity of the C-MARS-HA is acceptable. This questionnaire can be used for clinical evaluation of self-efficacy among Chinese hearing aid users.

Introduction

Hearing aids are commonly used for hearing-impairment rehabilitation. Factors that impact hearing aid effectiveness can be categorized as audiological and non-audiological. Non-audiological factors (self-efficacy and satisfaction with hearing aids) also have a significant impact on individuals with hearing deficits initiating and continuing to use hearing aids [13]. The effectiveness of hearing aids can be evaluated using subjective and objective methods. Subjective evaluation frequently involves users completing a questionnaire to understand their perceptions of the hearing aid effectiveness in their daily lives [4].

Research has confirmed that self-efficacy plays a positive role in disease treatment and rehabilitation, such as for tinnitus [5], diabetes [6], and other diseases. The self-efficacy of hearing aid users refers to their level of confidence in their ability to use hearing aids, reflecting their ability to adapt to and respond to changes brought about by hearing aids. Self-efficacy has a significant impact on the sustained use of hearing aids [7]. Users with high self-efficacy are more inclined to initiate and continue the use of hearing aids to cope with hearing difficulties. In contrast, users with low self-efficacy may limit or abandon their use of hearing aids [8]. Adherence to hearing aids is associated with improving listening ability, reducing activity restrictions caused by hearing impairment, improving cognition, and preventing falls [811].

The Measure of Audiologic Self-Efficacy for Hearing Aids (MARS-HA) questionnaire was developed by West and Smith to assess the level of confidence of hearing aid users in their ability to use and maintain hearing aids in diverse listening environments [7]. The MARS-HA consists of four factors. Factor 1 is aided listening (such as listening in quiet or noisy environments). Factor 2 is basic handling (such as battery installation). Factor 3 is adjustment (such as adapting to sounds heard after wearing the hearing aid), and Factor 4 is advanced handling (such as identifying different components of the hearing aid). These four factors are the main factors affecting the self-efficacy of hearing aid users. Experts have suggested that the self-efficacy score of hearing aid users should reach 80% [8]. Audiologists can determine the level of confidence of hearing aid users in aided listening, basic handling, adjustment and advanced handling with the MARS-HA. Audiologists can record the specific reasons why users feel lacking in confidence through further conversations with users. Therefore, the MARS-HA can estimate a new user’s ability to use hearing aids and analyze the difficulties of experienced users to assist audiologists in providing targeted guidance and suggestions. Evaluating and comparing the results of the MARS-HA before and after an intervention can reveal the effectiveness of the rehabilitation treatment [7,8,12]. The MARS-HA currently has versions in English [7,1317], Spanish [18], and French [19], all of which have acceptable reliability and validity.

The ultimate goal of conducting the MARS-HA questionnaire evaluation for experienced hearing aid users is to identify the difficulties they face when using hearing aids, provide rehabilitation advice, improve the effectiveness of the hearing aids, and help improve adherence and success in using hearing aids. Considering the positive effects and widespread applications of the self-efficacy and MARS-HA as elaborated above, the first aim of this study was to translate the MARS-HA into a Chinese version and determine/verify its reliability and validity. The second aim of this study was to analyze the self-efficacy of hearing aid users in China based on the results of the C-MARS-HA survey, thereby providing a reference for clinical applications.

Materials and methods

Participants

All participants were recruited at the Sixth People’s Hospital of Shanghai between June 1 and June 30, 2024. Selection criteria included: ① Age ≥ 18 years; ② using hearing aids in one or both ears for at least 6 months; ③ no obvious language, speech, or cognitive barriers.

Ethical information and informed consent

The ethics had been approved by the Ethics Committee of Shanghai Sixth People’s Hospital (Approval No. 2023−176). All participants read and signed a written informed consent form personally or with the assistance of their families.

Translation of Chinese version of the MARS-HA questionnaire

The adjusted version of the Brislin translation model proposed by Jones was strictly adopted for the translation [20]. Researchers and six experts participated in the translation of the questionnaire. All six experts are otolaryngologists or audiologists with professional backgrounds in otology and audiology. The translation process of the questionnaire is shown in Fig 1.

First, two audiologists from different dialect regions proficient in English and Chinese, respectively translated the English version of the MARS-HA into Chinese. Second, two other bilingual experts translated the two versions of the translated questionnaire back into English. Third, the researchers collaborated with the four aforementioned experts to compare the four translated versions with the original English versions. The most accurate and easily understandable Chinese version was determined.

The selected Chinese version questionnaire above was used for file testing. a small sample of 30 participants participated in the test. Tested the comprehensibility, logicality, and cultural adaptability of this questionnaire. Participants were required to independently complete the questionnaire, record and provide feedback on whether there were any logical errors or reading difficulties during the filling process. Immediately provided feedback on the above situation to the researchers after completing the test. Based on feedback, researchers and experts communicate and adjust Chinese expressions appropriately to better achieve cultural adjustment.

Two other bilingual experts then translated the Chinese version into English. Subsequently, all researchers and the six experts jointly discussed and compared the translated Chinese and English versions of the questionnaire with the original English version, ultimately achieving consistency between the Chinese and English versions in terms of concepts, semantics, and context. Cultural adjustments were included to make the questionnaire as understandable as possible. Finally, a Chinese version of the Measure of Audiologic Rehabilitation Self-Efficacy for Hearing Aids(C-MARS-HA) was developed.

Familiarity check was also conducted during the questionnaire translation process. The questionnaire was developed after a familiarity check from Chinese language experts then it was intended for content validation by 6 experts with professional backgrounds in otology and audiology.

Tool and processes

The C-MARS-HA tool consists of 24 items divided into four factors: aided listening (items 16–24), basic handling (items 1–5, 7, and 10), adjustment (items 13–15), and advanced handling (items 6, 8, 9, 11, and 12) [7]. The Chinese and English versions of the 24 items are listed in Table 1. A column of 0% −100% numbers (0%, 10%, 20%, until 100%) is located below each item, wherein 0% represents “no certainty in one’s capability” and 100% represents “complete certainty.”

thumbnail
Table 1. Items of the MARS-HA and results of exploratory factor analysis.

https://doi.org/10.1371/journal.pone.0330163.t001

The C-MARS-HA was conducted on-site by trained audiologists. The audiologists began by explaining to the participants that the 24 items in the questionnaire were about their ability to engage in certain activities related to hearing aids or their subjective perception of hearing when wearing hearing aids in certain situations. For each item, the participants were instructed to write or state a certain number (0%−100% as mentioned previously) that best represented their current ability or feeling. If the participants had never experienced a certain situation, they were asked to anticipate how well they would accommodate to the situation.

In addition to the 24 items included in the C-MARS-HA, we investigated the overall satisfaction of participants with the use of hearing aids by asking a standard question“您对您的助听器总体满意程度为______%([what is] Your overall satisfaction level with your hearing aids ______%).” reflecting the effectiveness of hearing aid use from different perspectives. The scores range from 0%−100%; 0% indicates complete dissatisfaction, while 100% indicates complete satisfaction.

Statistical analysis

After the survey was completed, the scores for each item were entered into a computer by two researchers and the data were revised as needed. All data were processed using SPSS Version 26.0. Reliability analysis including Cronbach’ s α, Spearman-Brown, and Guttman split-half coefficients; all had reference values greater than 0.6. Validity analysis included content and structural validity. Content validity was evaluated by peer review, whereas construct validity was analyzed by exploratory and confirmatory factor analyses, in which the Bartlett sphericity test showed a statistically significant difference (p < 0.05).

Descriptive statistical analyses of the total and four-factor scores of the C-MARS-HA and overall satisfaction were conducted. The total score was the average score of the 24 items, and the score for each factor represented the average score of the corresponding items. Smith and West suggested that the self-efficacy score of an effective hearing aid should reach 80%; therefore, the proportion of participants who achieved 80% was calculated [8]. A correlation analysis was conducted to reflect the relationship between the four factors and the relationship between the four factors and the total score. As the total score and the scores of the four factors did not conform to a normal distribution, Spearman’s correlation was used for analysis. Statistical significance for the correlation was considered at p < 0.05. For correlation analysis, the correlation was considered moderate or above when the absolute value of the correlation coefficient reached 0.5. Coefficients less than 0.5 were considered as low to moderate. The overall satisfaction score for the hearing aids was obtained from the corresponding questions.

Results

General information

This study included 134 participants aged 20–98, including 57 males and 77 females. 41 participants wore unilateral hearing aids, and 93 participants wore bilateral hearing aids. The types of hearing aids included BTE (Behind the ear), RIE (Receiver in ear), ITE (In the ear), ITC (In the canal), CIC (Complete in canal). The general information of the participants is shown in Table 2, and the degree of hearing loss is shown in Fig 2.

thumbnail
Fig 2. The hearing threshold of the pure tone test.

Ave, average value; Max, maximum value; Min, minimum value.

https://doi.org/10.1371/journal.pone.0330163.g002

Reliability

Internal consistency.

The overall Cronbach’ s α of the C-MARS-HA was 0.914, and the Cronbach’ s α of all four factors was greater than 0.6 (Table 3), indicating that the C-MARS-HA has good internal consistency.

thumbnail
Table 3. Results of reliability analysis and confirmatory factor analysis of the C-MARS-HA.

https://doi.org/10.1371/journal.pone.0330163.t003

Split-half reliability.

Split-half reliability analysis was mainly used to complement other reliability indicators such as Cronbach’s α, and to comprehensively evaluate the internal consistency of the questionnaire. The C-MARS-HA was divided into two parts based on odd and even item numbers. The split-half reliability analysis included Spearman Brown and Guttman split-half coefficients for the scores of the total, and each factor was calculated, all of which were greater than 0.6 (Table 3), indicating that the C-MARS-HA has good split-half reliability.

Validity

Content validity.

For content validity, questionnaire items were rigorously tested and repeatedly reviewed. During the introductory process, several experts from the Department of Otolaryngology strictly followed the standard process of the adjusted version of the Brislin translation model. The comprehensibility, logicality, and cultural adaptability of the Chinese version of the questionnaire were tested by a small sample of 30 participants. And familiarity check was conducted by researchers and 6 experts.

Some items in the questionnaire translation process had been revised. In item 8 (I can stop a hearing aid from squealing), the word “squealing” had been translated from “尖叫声” to “啸叫声” to help participants better understand that it referred to the whistling caused by factors such as improper wearing of the hearing aid. In item17 (I could understand conversation in a small group in a quiet place if I wore hearing aids), the translation of “conversation in a small group” had been translated from “小组间的对话” to “–对多人的谈话” to help participants better understand that this referred to conversations between one to many people. This adjustment formed a good progression with the translation of “a one-on-one conversation (–对–的谈话)” in item 16. Similarly, completed the translation adjustment for item 22.

Through the standard process above, ultimately achieved basic consistency between the Chinese and original English versions of the questionnaire in concept, semantics, and context. This confirmed the content validity of the C-MARS-HA.

Construct validity.

The results for construct validity are shown in Table 1. First, exploratory factor analysis was conducted on 134 samples, with a Kaiser-Meyer-Olkin (KMO) value of 0.861 and a Bartlett spherical value of 2895.612 (p < 0.01), indicating that the questionnaire results are very suitable for extracting information and reflect the good validity of the C-MARS-HA. Therefore, the questionnaire is suitable for factor analysis.

Next, principal component analysis (PCA) was used to conduct an exploratory factor analysis of the C-MARS-HA. In this study, based on the Kaiser criterion, 5 principal components greater than 1 were initially selected. Then, combined with the scree plot of Scree Text, cumulative variance contribution rate, and the number of factors in the original English questionnaire, it was observed that under the condition of 4 factor numbers, the cumulative variance contribution rate reached 71.307%, indicating that the selected principal components could already represent most of the information in the original data well. Therefore, after maximum variance rotation was completed, the final number of factors was determined to be 4. The cumulative variance contribution rate of the common factors was greater than 40%, the load coefficients of the corresponding factors were all greater than 0.4, and the commonality of all items was greater than 0.4. This indicates that the C-MARS-HA has good construct validity, and the corresponding relationship structure between items and factors is consistent with that of the original English version.

Next, confirmatory factor analysis was conducted on the 24 items. Convergent and discriminant validity tests were conducted (Table 3). The results of the convergent validity tests are represented by the average variance extraction value (AVE) and combined reliability value (CR). The AVE values of the four factors were all greater than 0.5, and the corresponding CR values were all greater than 0.7, indicating that the C-MARS-HA has good convergent validity.

The results of the discriminant validity tests are represented by the AVE square root value and the correlation coefficient between the factors. The AVE square root value represents the aggregation of factors and the correlation coefficient between factors represents the correlation relationship. When the AVE square root value of each factor is greater than the maximum correlation coefficient between that factor and other factors, it indicated that the questionnaire has good discriminant validity. The results of this analysis showed that the minimum AVE square root value corresponding to the four factors was 0.752, which was greater than the maximum value of the correlation coefficient between the factors (0.458), indicating that the C-MARS-HA has good discriminant validity.

The self-efficacy results of the C-MARS-HA

Descriptive statistical analysis was conducted on the total score and four factors of the C-MARS-HA and overall satisfaction with hearing aids among the 134 participants (Table 4). The average scores for basic handling and adjustment were greater than 80% (92.60% and 81.69%, respectively), and the proportions of users with scores reaching 80% for basic handling and adjustment were greater than 70% (91.04% and 70.90%, respectively), indicating that most users had good self-efficacy in basic handling and adjustment. However, the average scores for aided listening, advanced handling, and the total score were less than 80% (74.76%, 64.54% and 78.70%, respectively). A total of 58.96% of the participants reached the suggested level for the total score, whereas less than 50% of the participants reached the suggested level in aided listening and advanced handling (49.25% and 42.54%, respectively), indicating that most participants had poor self-efficacy in aided listening and advanced handling. The average overall satisfaction score was 81.14%, with 65.67% of the participants reaching 80%, indicating that more than half of the users were satisfied with the effectiveness of the hearing aids.

thumbnail
Table 4. Results of descriptive statistics of the C-MARS-HA survey.

https://doi.org/10.1371/journal.pone.0330163.t004

Spearman’s correlation analysis was conducted on the total score, scores of the four factors of the C-MARS-HA, and overall satisfaction score (Table 5). The correlations between the total score and the four factors, as well as between the four factors, were significant (p < 0.001). The correlations between aided listening and basic and advanced handling were the lowest (0.314 and 0.333, respectively), whereas the total score had the highest correlations with aided listening and advanced handling (0.774 and 0.783, respectively). The correlations between the total score, scores of the four factors, and the overall satisfaction score were significant (p < 0.001). These results indicate a significant positive correlation between the total score, four factors, and overall satisfaction with the C-MARS-HA. Moreover, the strength of the correlation varies.

thumbnail
Table 5. Results of Spearman correlation analysis between the C-MARS-HA and overall satisfaction.

https://doi.org/10.1371/journal.pone.0330163.t005

Discussion

The reliability and validity of the C-MARS-HA

West and Smith developed the MARS-HA and conducted a reliability and validity analysis of the survey results of new and experienced users of hearing aids (who were distinguished by whether they had used hearing aids for more than 6 months). The results showed that the MARS-HA has good reliability and validity [7].

For reliability verification in this study, the internal consistency and split-half reliability of the overall and four factors were analyzed (Table 3). The internal consistency was represented by Cronbach’s α. The overall and four factors of Cronbach’s α were all greater than 0.8 (the minimum value was 0.855), indicating that the C-MARS-HA has high reliability. The split-half reliability was represented by the Spearman-Brown and Guttman split-half coefficients. These two coefficients for the overall and four factors were both greater than 0.6 (the minimum value was 0.621), further confirming that the reliability of the C-MARS-HA meets statistical requirements.

For validity verification in this study, this study analyzed the content and construct validity of the Chinese version of the MARS-HA. First, after repeated experimentation and reviews strictly following the Brislin translation model for cross-cultural translation, file testing and familiarity check, the translated questionnaire was found to have good content validity (Fig 1). The MARS-HA also has Spanish and French versions, both of which used similar cross-cultural translation methods and have good validity [18,19].

Subsequently, through exploratory factor analysis (Table 1), four common factors that met the statistical requirements were extracted from the 24 items of the C-MARS-HA: Factor 1 (aided listening, corresponding to items 16–24), Factor 2 (basic handling, corresponding to items 1–5,7,10), Factor 3 (adjustment, corresponding to items 13–15), and Factor 4 (advanced handling, corresponding to items 6,8,9,11,12), which were consistent with the factors of the original questionnaire. After rotation, the cumulative variance contribution rate of the common factors was greater than 40% (reached 70.307%), and the load coefficients of the corresponding factors were all greater than 0.4 (the minimum value was 0.466). The commonality of all items was greater than 0.4 (the minimum value was 0.424), indicating that the C-MARS-HA has good structural validity.

A confirmatory factor analysis was performed for further testing (Table 3). The AVE values of all four factors were greater than 0.5 (the minimum value was 0.565), and the CR values were greater than 0.7 (the minimum value was 0.865), indicating that the C-MARS-HA has good convergent validity. The minimum square root value (0.752) of the AVE corresponding to the four factors was greater than the maximum value (0.458) of the correlation coefficient between the factors, indicating that the C-MARS-HA has good discriminant validity.

Based on the reliability and validity analysis of C-MARS-HA mentioned above, the questionnaire has good reliability and validity.

The self-efficacy results of the C-MARS-HA

The results of the C-MARS-HA survey targeting 134 participants showed self-efficacy of those participants (Table 4). The hearing aid users scored 80% of the recommended level for basic handling (reached 92.60%) and adjustment (reached 81.69%), and that the proportion of users who reached this level exceeded 70% (reached 70.90% and 91.04%). The scores for aided listening and advanced handling were relatively low (reached 74.76% and 64.54%). These results are consistent with those of other studies of the MARS-HA conducted in multiple countries and regions [7,1419]. Approximately 66% of the users achieved a good level of overall satisfaction with hearing aids.

The score for basic handling was relatively high. This may have occurred because skills such as battery replacement are frequently performed by users. Hearing aid users usually receive training during their initial fitting; therefore, one would expect that they would be more proficient in these skills and have a higher level of confidence [15]. The adjustment score was also better, which may be because all the participants included in this study were experienced hearing aid users. Audiologists adjusted the hearing aids based on the user’ s hearing levels, and regular follow-up visits were conducted to adjust the hearing aid settings according to the usage. Any problems encountered by the users were promptly addressed.

The low self-efficacy in aided hearing may have been due to the following. First, all participants included in this study were experienced hearing aid users. After using hearing aids for a certain period, experienced users are aware that hearing aids cannot solve all hearing problems [7]. Second, most participants were of advanced ages, and hearing impairment may worsen with age, leading to more obvious problems. Low self-efficacy in advanced handling is common, indicating that troubleshooting and similar operations are challenging for hearing aid users [7,1419]. In this survey, most users believed that advanced handling requires professional personnel, and that they do not have the ability to perform tasks involved with advanced handling of the hearing aids. Therefore, upon encountering these types of problems, the hearing aid users will seek the help of professionals.

The scores of the total and four factors of the C-MARS-HA had significant positive correlations with each other (Table 5), further verifying the good internal consistency of the C-MARS-HA. These results are consistent with the results of the Spanish version of the questionnaire survey [18]. The difference in correlation strength also reflects the need for an overall evaluation of self-efficacy with an emphasis on different factors. The C-MARS-HA scores also had a significant positive correlation with overall satisfaction, with differences found in the correlations between each item. The correlation between overall satisfaction and aided listening or adjustment was relatively high compared with those of basic and advanced handling, indicating a higher correlation between user satisfaction and auditory perception.

Our survey revealed an average total score for self-efficacy of hearing aid users of 78.70%, and an average score for overall satisfaction of 81.14%, indicating that the self-efficacy of the hearing aid users could be improved. Providing simple and understandable written materials and video demonstrations and engaging the significant others of users to participate in the daily management and rehabilitation training of hearing aids may lead to further improvements in self-efficacy [8,14,21].

Limitations

In this study, we invited experienced hearing aid users and conducted a questionnaire survey on them. We focused on using MARS-HA to assess participants’ subjective feelings and future research can further compare the correlation between subjective and objective data. Due to the uncertainty of participants follow-up and the limitation of research time, there are shortcomings in this study in terms of test-retest reliability, number of participants, long-term performance of self-efficacy, and analysis of factors affecting self-efficacy. In future research, we will try our best to arrange the research plan reasonably, overcome existing difficulties, and strive to further improve the study and enhance the quality of the research.

Conclusion

In summary, our results revealed that the C-MARS-HA has good reliability and validity. This tool is suitable for clinical evaluation of the confidence level of users in their abilities to listen with, handle, and adjust hearing aids, reflecting the benefits and difficulties of hearing aid use. The survey results showed that hearing aid users from China have good self-efficacy in basic handling and adjustment but poor self-efficacy in aided listening and advanced handling. And hearing aid self-efficacy is associated with overall satisfaction with hearing aids. The information derived from this questionnaire will assist audiologists in planning and managing the care of individuals using hearing aids.

Supporting information

S1 Annex. The Chinese version of audiologic rehabilitation self-efficacy for hearing aids (C-MARS-HA).

https://doi.org/10.1371/journal.pone.0330163.s001

(DOCX)

Acknowledgments

The authors would like to thank all research participants for their time and interest in this study.

References

  1. 1. Johnson CE, Jilla AM, Danhauer JL, Sullivan JC, Sanchez KR. Benefits from, Satisfaction with, and Self-Efficacy for Advanced Digital Hearing Aids in Users with Mild Sensorineural Hearing Loss. Semin Hear. 2018;39(2):158–71. pmid:29915453
  2. 2. Jorbonyan A, Momtaz YA, Foroghan M, Mehrkian S. Factors Affecting the Adoption and Use of Hearing Aids among Older Adults: A Systematic Review. Curr Psychiatry Res Rev. 2021;17(3):172–87.
  3. 3. Jorbonyan A, Abolfathi Momtaz Y, Foroughan M, Mehrkian S. Determinants of Continuance Intention to Use Hearing Aids among Older Adults in Tehran (Iran). Healthcare (Basel). 2024;12(4):487. pmid:38391862
  4. 4. Schow RL, Nerbonne MA. Introduction to Audiologic Rehabilitation. Pearson Education; 2017.
  5. 5. Fagelson MA, Smith SL. Tinnitus Self-Efficacy and Other Tinnitus Self-Report Variables in Patients With and Without Post-Traumatic Stress Disorder. Ear Hear. 2016;37(5):541–6. pmid:26950001
  6. 6. Guo J, Yang J, Wiley J, Ou X, Zhou Z, Whittemore R. Perceived stress and self-efficacy are associated with diabetes self-management among adolescents with type 1 diabetes: A moderated mediation analysis. J Adv Nurs. 2019;75(12):3544–53. pmid:31441523
  7. 7. West RL, Smith SL. Development of a hearing aid self-efficacy questionnaire. Int J Audiol. 2007;46(12):759–71. pmid:18049965
  8. 8. Smith SL, West RL. The application of self-efficacy principles to audiologic rehabilitation: a tutorial. Am J Audiol. 2006;15(1):46–56. pmid:16803791
  9. 9. Dawes P, Emsley R, Cruickshanks KJ, Moore DR, Fortnum H, Edmondson-Jones M, et al. Hearing loss and cognition: the role of hearing AIDS, social isolation and depression. PLoS One. 2015;10(3):e0119616. pmid:25760329
  10. 10. West JS, Smith SL, Dupre ME. Self-reported hearing loss, hearing aid use, and cognitive function among U.S. older adults. Int J Popul Stud. 2022;8(1):17–26. pmid:37304046
  11. 11. Riska KM, Peskoe SB, Kuchibhatla M, Gordee A, Pavon JM, Kim SE, et al. Impact of Hearing Aid Use on Falls and Falls-Related Injury: Results From the Health and Retirement Study. Ear Hear. 2022;43(2):487–94. pmid:34334680
  12. 12. Meijerink JF, Pronk M, Lissenberg-Witte BI, Jansen V, Kramer SE. Effectiveness of a Web-Based SUpport PRogram (SUPR) for Hearing Aid Users Aged 50+: Two-Arm, Cluster Randomized Controlled Trial. J Med Internet Res. 2020;22(9):e17927. pmid:32960175
  13. 13. Smith S, Lea West R. Hearing Aid Self-Efficacy of New and Experienced Hearing Aid Users. Semin Hear. 2006;27(4):325–9.
  14. 14. Hickson L, Meyer C, Lovelock K, Lampert M, Khan A. Factors associated with success with hearing aids in older adults. Int J Audiol. 2014;53 Suppl 1:S18-27. pmid:24447233
  15. 15. Kelly-Campbell RJ, McMillan A. The Relationship Between Hearing Aid Self-Efficacy and Hearing Aid Satisfaction. Am J Audiol. 2015;24(4):529–35. pmid:26650773
  16. 16. Ferguson MA, Woolley A, Munro KJ. The impact of self-efficacy, expectations, and readiness on hearing aid outcomes. Int J Audiol. 2016;55 Suppl 3:S34-41. pmid:27266542
  17. 17. Convery E, Keidser G, Seeto M, McLelland M. Evaluation of the Self-Fitting Process with a Commercially Available Hearing Aid. J Am Acad Audiol. 2017;28(2):109–18. pmid:28240978
  18. 18. Fuentes-López E, Fuente A, Valdivia G, Luna-Monsalve M. Does educational level predict hearing aid self-efficacy in experienced older adult hearing aid users from Latin America? Validation process of the Spanish version of the MARS-HA questionnaire. PLoS One. 2019;14(12):e0226085. pmid:31856164
  19. 19. Vincent C, Gagné J-P, Leroux T, Clothier A, Larivière M, Dumont FS, et al. French-Canadian translation and validation of four questionnaires assessing hearing impairment and handicap. Int J Audiol. 2017;56(4):248–59. pmid:27981872
  20. 20. Jones PS, Lee JW, Phillips LR, Zhang XE, Jaceldo KB. An adaptation of Brislin’ s translation model for cross-cultural research. Nurs Res. 2001;50(5):300–4.
  21. 21. Meyer C, Hickson L, Fletcher A. Identifying the barriers and facilitators to optimal hearing aid self-efficacy. Int J Audiol. 2014;53 Suppl 1:S28-37. pmid:24447235