Figures
Abstract
Background
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has had a global impact, underscoring the importance of personal protective equipment (PPE). Use of N95s reduces the risk of airborne infection; however, in the absence of equitable designs, health care workers (HCWs) who do not fit the average White male head and face are at an increased risk of airborne infectious diseases.
Objectives
Primary: Feasibility of a mixed-method study, with a sample size of 100, 50% of participants self-identifying as non-White and having at least one characteristic of interest. Secondary: (1) Generate quantitative evidence on N95 fit using a PortaCount fit test, (2) describe participant-reported feelings on fit and breathability, and (3) evaluate the impacts of the pandemic on a HCW’s physical and mental well-being.
Methods
This was a mixed-method prospective pilot and feasibility study. Quantitative fit was assessed using a TSI PortaCount test and measurements of bizygomatic breadth and Menton-Sellion length. A survey was administered to collect sociodemographic information, HCWs’ assessment of N95 fit, comfort, and the impact of PPE-related challenges on well-being.
Results
This study was limited by a small sample size, as COVID-19 pandemic restrictions prevented adequate recruitment to detect differences between groups. We describe key findings that should inform analyses of the impact of gender and ethnicity on N95 respirator fit. Following a study amendment to increase eligible sites, 37 of the 41 (90.2%) approached HCWs consented to participate. Compared to other HCWs, non-White females had the lowest mean fit factor. Differences in Menton-Sellion length and bizygomatic breadth were observed between males, females, and White and non-White HCWs. Most HCWs reported physical discomfort and negative impacts on their psychological well-being.
Citation: Sheikh F, Dolovich M, Schwartz L, Khan S, Hosseinidoust Z, Fox-Robichaud AE (2025) Evaluating N95 respirator designs: A mixed-methods pilot and feasibility study. PLoS One 20(12): e0328746. https://doi.org/10.1371/journal.pone.0328746
Editor: Christophe Curti, Assistance Publique - Hôpitaux de Marseille, FRANCE
Received: July 7, 2025; Accepted: October 22, 2025; Published: December 3, 2025
Copyright: © 2025 Sheikh et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the manuscript and its Supporting Information files.
Funding: This study was funded by the Canadian Institute for Health Research (CIHR) (202005VR4-447804-CCF) for one year beginning June 1st, 2020. FS was also supported by an Ontario Graduate Fellowship Award during the conduct of this study. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Competing interests: The authors have declared that no competing interests exist.
Introduction
Coronavirus disease (COVID-19) has had a global impact, with more than 770 million confirmed cases and 6.9 million deaths reported worldwide [1]. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that causes COVID-19, can be transmitted by respiratory droplets and aerosols [2,3]. In healthcare settings, SARS-CoV-2 can be aerosolized during aerosol-generating procedures (AGP); aerosolized viral particles less than 5μm in size can pass through the pores of surgical masks. N95 respirators have been the recommended PPE for HCWs involved in caring for patients requiring AGPs throughout the pandemic [4,5]. SARS-CoV-2 and other airborne pathogens are an ongoing concern in healthcare settings.
N95 respirators offer the greatest protection and are essential for protection against airborne infectious agents [6–8]. According to the National Institute for Occupational Safety and Health (NIOSH), the national body that regulates N95 standards in the United States (US) and Canada, N95s must have at least 95% filtration efficiency to prevent inhalation of airborne particles less than 0.3μm in size and be closely fitted to the face [9]. The majority of current PPE, including masks and respirators, have been designed based on the anthropometric facial measurements of average men in the US and Europe [10,11]. The reliance on historical anthropometric data poses challenges for those who do not fit these criteria, including women [12–15]. In Canada, women represent 82% of HCWs [16]. With the vast majority of PPE designed for the average male head and face, a sizeable portion of the workforce may be wearing poorly fitting PPE for long periods. The inability to access appropriately fitting protection not only increases the risk of COVID-19, but can lead to physical and psychological discomfort [17].
This bias in design affects more than women. An international study of facial morphology found significant differences in nose height and width between Caucasian North Americans compared to Asian and Black ethnic groups, and significantly greater bizygomatic width in Caucasian men and Asians, among other differences [18]. Women and ethnic men who do not meet these standards are challenged to find well-fitted and comfortable N95s. In the absence of a tight fit or an appropriate seal, N95s may not provide the required protection, putting HCWs at risk of contracting airborne pathogens [11]. Despite international research [14,19–22], no comparable studies have been conducted in Canada, where the healthcare workforce is increasingly diverse, underscoring the need for locally relevant evidence to inform respirator design and testing.
The purpose of this mixed-methods study was to [1] assess the feasibility of examining the fit of N95s in a diverse population of Canadian HCWs; [2] examine the outcomes of quantitative fit testing; and [3] describe qualitative measures of HCW-reported perceptions of N95 fit, breathability and comfort, and the impacts of PPE-related challenges on the physical and mental well-being of HCWs.
Methods
Study design
We conducted a mixed-method prospective pilot feasibility study designed to assess the qualitative and quantitative fit, comfort, and breathability of N95s in a diverse population of HCWs. A convergent parallel design was used in which qualitative and quantitative data were collected in parallel, analyzed separately, and then merged for interpretation [23,24]. Incorporation of the results of the quantitative fit test with the qualitative data of the survey occurred in the interpretation phase. The objectives, outcome measures and analysisof this study are shown in S1 Table.
Quantitative study methods
To assess the fit of an N95, a trained professional performed a quantitative fit test, using the TSI 8030 PortaCount Respirator Fit Tester, according to the NIOSH standard testing procedures [25]. The quantitative fit test consisted of seven exercises designed to assess the amount of leakage around the face seal. The results of the quantitative test were recorded for each of the following exercises: normal breathing (performed at the start and end), deep breathing, turning the head side-to-side, nodding the head up and down, speaking out loud, and bending over. The overall fit factor, a ratio of aerosol concentration outside and inside the respirator, was also recorded [26,27]. A minimum overall fit factor of 100 was necessary to pass. If the individual failed the test with the first respirator, the fit test was stopped, reported as an unsuccessful fit, and repeated at least once more prior to testing with a different N95 respirator. The following respirators were available: 3M 1870 + , 1860, 1860S, 1804S, and the Honeywell DC 365. Healthcare workers previously fitted to an N95 were offered the same respirator to start.
The bizygomatic breadth, defined as the maximum horizontal breadth of the face, and the Menton-Sellion length, defined as the distance between the Menton and Sellion landmarks, were measured using sliding calipers (VWR Model: 12777−830). Both measures were recorded in millimeters for each participant, according to NIOSH testing procedures [28]. These facial measurements were mapped to the NIOSH bivariate panel [28] corresponding to a range of face widths and lengths.
Qualitative study methods
To determine the diversity of experiences with wearing N95s, we conducted a qualitative description study to explore the perspective of healthcare workers [29,30]. We designed a paper-based survey which was administered to frontline HCWs who underwent the quantitative fit test (S1 File). Prior to administering the survey, we assessed the suitability of the questions, readability, and overall clarity with a sample of critical care HCWs (n = 3). Minor changes were made to improve the clarity of questions. No questions were added or removed, and no other significant changes were made.
Recruitment and participants
Potential participants included HCWs, defined as a healthcare provider (e.g., physician, nurse, respiratory therapist, etc.) or any patient-facing staff, at one of the three Hamilton Health Sciences (HHS) hospitals in Hamilton, Ontario, Canada.
Convenience and purposive sampling strategies were used to recruit participants who were readily accessible, willing to participate, and would facilitate an analysis of the effects of gender and ethnicity on the fit of N95s [31]. Participants were restricted to HCWs who worked on-site during the study period due to pandemic-related restrictions.
Inclusion criteria.
- 18 years of age or older
- Healthcare worker or patient-facing staff at HHS
- Informed consent to participate in the fit test and complete the survey.
And 50% of the sample must also meet at least one of the following conditions:
- Self-identity as being non-White
- Have at least one of the following characteristics: religious head covering (e.g., Hijab, Turban), glasses, and/or facial hair (e.g., beard and/or mustache)
- Identify as female
To ensure adequate representation of participants from diverse backgrounds, we established an a priori requirement that at least 50% of participants be non-White. This criterion was based on prior evidence that respirator fit may vary by ethnicity and aimed to avoid overrepresentation of White participants, thereby supporting a more inclusive and equity-focused analysis.
Analysis
Secondary outcomes.
- (1) Quantitative Fit Test Results. The results of the quantitative fit test are described with descriptive statistics. Specifically, the results for each of the seven exercises and the overall fit factor are reported as mean ± standard deviation (SD). These results are presented in aggregate, by gender, and by ethnicity. Data were reported by male and female, as no other genders were reported, and as White and Non-White due to limited sample size across each individual ethnicity. All data analysis was performed using SPSS Statistics Version 27 (IBM, Chicago, IL). Due to the small sample size and risk of detecting a significant difference between males and females or the various ethnic groups, when, in fact, there was no difference (i.e., Type II error), no inferential statistics were run [32]. Instead, descriptive statistics were presented to characterize patterns in the data, complemented by qualitative findings to provide context.
- (2) Measure of N95 Fit; and [3] Impacts related to PPE on physical and mental health. Domains evaluated in the survey using Likert scales, are summarized using medians and frequencies, where applicable [33]. Qualitative description was used to guide the reporting and analysis of the open-ended survey results, to ensure that the reported data directly reflect what the HCWs said, and how it was said [29]. HCW-reported data on N95s were narratively summarized, and reported in tables, organized by N95 fit, comfort, and breathability and their impacts on the physical and mental health of the HCWs.
To represent the convergent integration of both datasets, these data were summarized in the form of a “statistics-by-theme joint display” [34], where de-identified quotes are reported along with relevant numeric results and sociodemographic information collected in the two phases of the study. Specifically, the integration of quantitative and qualitative findings was conducted through an iterative process, in which authors independently reviewed the quantitative and qualitative survey results and then collaboratively organized the findings into a joint display to highlight points of convergence and divergence. This approach ensured that both data sources were represented and that the joint display accurately reflected the descriptive nature of the qualitative findings.
Results
Feasibility results
Feasibility results were collected up to May 6th, 2022. The flow of potentially eligible participants, beginning with the total number of fit tests conducted between January 4th and May 6th at Hamilton General Hospital (HGH), and between March 14th and May 6th, at Juravinski Hospital (JH) and McMaster Children’s Hospital (MCH), are shown in Fig 1.
aRecruitment began at Juravinski and McMaster Children’s Hospital on March 10th. The total number of fit tests completed at each of these sites prior to March 10th is not reported.
The results of the primary objectives, designed to assess the feasibility of conducting this study, are summarized in Table 1. Overall, study recruitment was well below the target (100 HCWs), with only 36 of the target 100 (36%) HCWs enrolled in the study. The primary reasons for low enrollment were the increased need for fit tests, the limited amount of time HCWs had, and for the first two months of the study, the limited number of days the fit test clinic was run. There were some additional challenges with equipment failure and the time required to have it repaired. Study recruitment increased slightly following the addition of two study sites (S2 File); however, challenges persisted, and the recruitment rate was low with only 36 of the 653 (5.5%) potentially eligible HCWs recruited. No other reasons, beyond time, were reported by HCWs or observed by the study team.
In the sample of HCWs approached for inclusion in the study, 37 of the 41 (90.2%) HCWs consented to participate in the study and 36 of the 41 (97.3%) were successfully fitted via the quantitative method. Additionally, 23 of the 36 (63.9%) included HCWs were fitted on the first try, while the remaining 13 required more than one fit test. One HCW was could not be fitted using the quantitative method due to equipment failure.
Among the 654 fit tests completed between January 4th and May 2nd, we were still unable to approach 612 potentially eligible HCWs due to time constraints or, on occasion, due to equipment failure. The research team felt it was important to ensure that the research did not “compromise the public health response to [the] outbreak or the provision of clinical care.” [35] As a result, HCWs were approached for study participation if [1] there was no line-up at the fit test clinic, [2] the HCW did not express time constraints or the need to return to clinical duty, and [3] the addition of one more person to the room, while other fit tests were ongoing, did not exceed the capacity limit. A summary of the feasibility results are displayed in Table 1.
Quantitative fit test results
Thirty-six HCWs were recruited and completed the quantitative fit test and survey (Fig 1). The characteristics of the included participants are reported in Table 2.
The overall mean fit factor for all HCWs was 173 (SD = 29.96), while male HCWs had a mean fit factor of 184 (SD = 28.0) compared to female HCWs, who on average had a fit factor of 170 (SD = 30.0). White HCWs had a fit factor of 178 (SD = 30.0), approximately 11 points higher than their non-White counterparts. Both the mean Menton-Sellion length, 122.87 mm (SD = 8.56) vs. 111.4 mm (SD = 9.37), and the mean bizygomatic breadth, 121.93 mm (SD = 8.4) vs. 109.26 mm (SD = 10.17), were longer in males compared to females. White HCWs had a slightly longer Menton-Sellion length, and non-White HCWs had a higher bizygomatic breadth value, compared to non-White and White HCWs, respectively.
To assess the combined effects of gender and ethnicity, the results of the quantitative fit test from 35 HCWs are summarized by gender and ethnicity in Table 3. One HCW was excluded from this analysis as they were fitted to a P100, the results of which were out of range. White males had a mean fit factor of 200 (SD = 0), the maximum score attainable, and non-White males had a mean fit factor of 175 (SD = 31.0), compared to White and non-White females who had mean fit factors of 175 (SD = 32.0) and 165 (SD = 30.0), respectively.
The Menton-Sellion length was longer in White males compared to non-White males, and the bizygomatic breadth showed the opposite trend. Non-White female HCWs had the shortest Menton-Sellion length and bizygomatic breadth, with mean values of 108.99 mm (11.31) and 107.82 mm (9.12), compared to White female and male HCWs. When these values were assigned to the NIOSH bivariate panel, 27 of the 36 (75%) HCWs were out of range, 4 of the 36 (11.1%) were assigned to panel 6, 3 (8.3%) were assigned to panel 3, 1 (2.8%) was assigned to panel 4, and 1 (2.8%) was assigned to panel 1 (Fig 2). This finding suggests that current respirator design and testing standards may not adequately capture the facial anatomy of a diverse healthcare workforce. The raw data to complete the quantitative analyses is found in S2 Table.
The facial measurements of the 36 included HCWs are displayed alongside the NIOSH bivariate panel. These panels correspond to a range of face widths (120.5–158.5 mm) and lengths (98.5–138.5 mm) and recommend number of participants to include from each panel when testing new respirators. Twenty-seven of the thirty-six (75%) included HCWs in this study were out of range, demonstrating differences in this sample and the testing standards.
Qualitative survey results
Thirty-six (100%) HCWs completed the survey and responded to at least 80% of the questions. On a scale of one to ten, where one is poor and ten is excellent, HCWs, on average, reported their experiences with N95s as a 6. There were no differences in reported experiences between White and non-White HCWs; however, male HCWs had a higher average score of 6.5, compared to female HCWs. Twenty-eight (77.8%) HCWs reported experiencing physical discomfort, 23 (63.9%) experienced pressure/pain, 14 (38.9%) experienced headaches, and 12 (33.3%) reported experiencing itching wearing an N95 respirator. Less frequent concerns included dizziness, reported by 8 (22.2%) HCWs, and nausea, reported by 2 (5.6%) HCWs.
A summary of quantitative and qualitative measures of N95 fit, comfort, and breathability, grouped by gender and ethnicity, are reported in Tables 4 and 5, respectively. On a five-point Likert scale, where 0 is poor and 4 is excellent or very good, both male and female HCWs had a median value of 3, corresponding to an agreement with the statement “N95 respirators fit me well”. While male HCWs reported the comfort of N95 respirators as a 2, female HCWs reported the comfort of N95 respirators as a 1 out of 5. This was reflected in the open responses, with one female HCW stating that “With the 1860s mask, it was extremely uncomfortable, difficult to breathe in. I would say it fit fine, but everything else was not great.” In terms of breathability, male HCWs reported an average score of 3, compared to females who reported an average score of 2. In addition to the perceived fit of N95s, females reported lower measures of N95 comfort and breathability.
When comparing the experiences of wearing N95s between White and non-White HCWs, the median scores for fit and breathability were the same. HCWs in each of these groups reported similar concerns, including respirators being too tight and causing red marks on their face when worn for prolonged periods of time. In terms of comfort, the median score in White HCWs was 1 compared to a median score of 2 in non-White HCWs. However, both groups reported feelings of tightness and negative experiences exacerbated by wearing glasses or unique facial characteristics. For example, a HCW who self-identified as White stated “Find it challenging to wear with my glasses. Find my mask a bit awkward on my face. Breathable but give me headaches when I wear all day.” Similarly, a HCW who self-identified as Vietnamese reported that it was “difficult finding appropriately sized masks due to small nasal bridge.”
Additional qualitative results, including the impact of N95s on the mental health of HCWs, are summarized in S3 File. These direct excerpts illustrate the negative impacts of existing N95s on the mental health of healthcare workers, and, more importantly, the breadth of these impacts, including their ability to communicate with patients, feel safe while at work, and their overall comfort.
Discussion
This study aimed to explore the fit, comfort, and breathability of N95 respirators in a diverse population of HCWs, and the first, to our knowledge, to compare fit testing outcomes with qualitative descriptions from the perspective of front-line HCWs during the peak of the COVID-19 pandemic. Although we were unable to approach the majority of potentially eligible HCWs who came to the fit test clinic, due to the increased need for fit tests and limited time, all HCWs with whom the project was discussed were eager to participate, highlighting the importance of this study and reflected in the high consent rate.
In addition to the primary feasibility outcomes, we evaluated the results of the quantitative N95 fit test and the survey data of the 36 included HCWs. When comparing the results between male and female HCWs, we found that, on average, male HCWs had a higher fit factor compared to female HCWs. In a study that examined the fit factor in a group of HCWs, Wardhan et al. found that women had higher fit failure rates, defined as a fit factor less than 100, compared to men [36]. These findings are consistent with studies by McMahon et al. [15] and Lee et al. [37], which demonstrated a 10% difference in fit failure rate between males and females, with females having a higher fit failure rate. Consistent with previous studies comparing anthropometric measures between males and females, we also identified differences in the key measures used to inform the design of N95s, between males and females.
When stratified by ethnicity, White HCWs had a higher fit factor compared to non-White HCWs, and both White and non-White males had higher fit factors, compared to their female counterparts. During the first wave of the COVID-19 pandemic, Green et al. analyzed the outcomes of fit tests across National Health Service hospitals in the United Kingdom. In addition to demonstrating differences in fit failure rates between men and women, they found that Black, Asian, and Minority Ethnic (BAME) HCWs had significantly higher fit failure rates compared to non-BAME HCWs [38]. Similarly, Chopra et al. found that females and BAME participants had lower fit factor scores and fit test pass rates, which was attributed to differences in facial features. Specifically, they identified 14 standardized anthropometric measures that were significantly smaller for females. Despite limited disaggregated data on facial measurements of BAME individuals, they also reported differences in facial geometry, face size and nose measurements between Asian, Black, and Caucasian individuals [21]. These differences in fit failure rates between men, women, and various ethnic groups can be explained by differences in head and face anthropometrics, as these studies have demonstrated significant differences between genders [12,13] and ethnicities [18,21,39].
There is a growing body of evidence on how gender and ethnicity affect respirator fit. Several studies report higher fit test failure rates among women and ethnic minority groups [14,19–21,40,41], while others attribute fit primarily to individual facial dimensions and the design of the respirator [12,22,42,43]. Our findings contribute to this literature by combining quantitative fit testing with descriptive qualitative insights from HCWs, who described discomfort, skin irritation, and psychological stress associated with respirator use – issues frequently noted by female and racialized participants. Ultimately, these differences highlight the importance of population-specific studies, as respirator fit reflects both individual and group-level anthropometric differences. To our knowledge, none of these studies have been conducted in Canada, where the healthcare workforce is increasingly diverse [44,45]; thus, locally gathered evidence is essential to guide respirator designs and fit testing protocols.
This study was limited by the number of HCWs we were able to recruit and the shortened study period and the absence of participants with religious head coverings or facial hair. The small sample size, specifically in the quantitative arm of our study, limited our analyses and our ability to run inferential statistics and report statistical differences. There may also have been differences in HCW characteristics and N95 fit testing outcomes between HCWs we were able to approach and HCWs we were unable to approach, which may limit the generalizability of the study results. Recruitment challenges were the result of the COVID-19 pandemic and persisted even after the study amendment was submitted. Despite these limitations, our study has several strengths: (1) this study of N95s in a diverse sample of HCWs, particularly in the absence of recognized Canadian standards by hospitals and limited Canadian respirator designs, is timely (2) used rigorous and objective methodology for conducting fit tests, and (3) included the collection of quantitative and qualitative data on N95 fit, comfort, and breathability.
In summary, we identified differences in the outcomes of the quantitative fit test and perceived measure of N95 and surgical mask fit between males, females, and various ethnic groups. Women make up approximately 82% of the current healthcare workforce, many of whom identify as a visible minority. Although recruitment challenges in this study were largely attributable to COVID-19 surge conditions, the disparities observed by gender and ethnicity are consistent with prior work and therefore likely to persist beyond the pandemic. The challenges around N95s and other PPE, including the negative impacts to physical and psychological well-being, will persist in the absence of equitable designs. Future studies, to assess the fit and comfort of current respirators, are necessary to inform evidence-based testing and new national standards for N95s used in healthcare settings. Specifically, future studies should (1) employ strategies for recruiting a truly diverse sample of HCWs, (2) include additional anthropometric measures that better account for face and head shape, and (3) explore factors such as occupation and duration of wear that may contribute to the fit and comfort of N95 respirators worn over the HCW working shift of 10–12 hours.
Conclusion
This study was conducted during the COVID-19 pandemic, when restrictions on in-person research limited recruitment and resulted in a small sample size. While this precluded statistical comparisons between groups, the preliminary findings provide important insights into gender- and ethnicity-related variation in respirator fit among Canadian healthcare workers. The COVID-19 pandemic has highlighted and exacerbated concerns around the fit, comfort, and breathability of PPE, and specifically N95 respirators. The results of this pilot study highlight the differences in fit between males and females and HCWs of different ethnic groups, as well as the disproportionate impacts on the physical and mental well-being of female and non-White HCWs. Importantly, this pilot study provides the scientific rationale for conducting the main study, particularly in the absence of pandemic restrictions, to answer this equity-focused and policy-relevant research question. In addition, these findings highlight the urgent need to update current respirator design and testing standards. Canadian standards and manufacturers should include anthropometric data that reflects gender and ethnic diversity to ensure that PPE provides equitable protection for all HCWs.
Supporting information
S1 Table. Objectives, Outcome Measures, and Analysis.
https://doi.org/10.1371/journal.pone.0328746.s001
(DOCX)
S3 File. Additional Results of the Qualitative Survey.
https://doi.org/10.1371/journal.pone.0328746.s005
(DOCX)
Acknowledgments
We would like to thank Jeff Mallany, Senior Safety Specialist (Hamilton Health Sciences), and Bonnie Peacock, Safety Fit Tester (Hamilton Health Sciences), for their expertise and willingness to support this research project.
References
- 1. Weekly epidemiological update on COVID-19 - 1 September 2023 [Internet]. [cited 2023 Oct 12]. Available from: https://www.who.int/publications/m/item/weekly-epidemiological-update-on-covid-19---1-september-2023
- 2. Jarvis MC. Aerosol Transmission of SARS-CoV-2: Physical Principles and Implications. Front Public Health. 2020;8:590041. pmid:33330334
- 3. Morawska L, Cao J. Airborne transmission of SARS-CoV-2: The world should face the reality. Environ Int. 2020;139:105730. pmid:32294574
- 4. Howard BE. High-Risk Aerosol-Generating Procedures in COVID-19: Respiratory Protective Equipment Considerations. Otolaryngol Head Neck Surg. 2020;163(1):98–103. pmid:32396451
- 5. D’Silva DF, McCulloch TJ, Lim JS, Smith SS, Carayannis D. Extubation of patients with COVID-19. Br J Anaesth. 2020;125(1):e192–5. pmid:32303376
- 6. Chu DK, Akl EA, Duda S, Solo K, Yaacoub S, Schünemann HJ. Physical distancing, face masks, and eye protection to prevent person-to-person transmission of SARS-CoV-2 and COVID-19: a systematic review and meta-analysis. Lancet. 2020;395(10242):1973–87.
- 7. Plana D, Tian E, Cramer AK, Yang H, Carmack MM, Sinha MS, et al. Assessing the filtration efficiency and regulatory status of N95s and nontraditional filtering face-piece respirators available during the COVID-19 pandemic. BMC Infect Dis. 2021;21(1):712. pmid:34325673
- 8. Greenhalgh T, MacIntyre CR, Baker MG, Bhattacharjee S, Chughtai AA, Fisman D, et al. Masks and respirators for prevention of respiratory infections: a state of the science review. Clin Microbiol Rev. 2024;0(0):e00124-23.
- 9. NIOSH guide to the selection and use of particulate respirators certified under 42 CFR 84. 2020 Oct 6 [cited 2022 June 26]; Available from: http://www.cdc.gov/niosh/docs/96-101/default.html
- 10. PPEandwomenguidance.pdf [Internet]. [cited 2022 June 22]. Available from: https://www.tuc.org.uk/sites/default/files/PPEandwomenguidance.pdf
- 11. Janson DJ, Clift BC, Dhokia V. PPE fit of healthcare workers during the COVID-19 pandemic. Appl Ergon. 2022;99:103610.
- 12. Zhuang Z, Bradtmiller B. Head-and-face anthropometric survey of U.S. respirator users. J Occup Environ Hyg. 2005;2(11):567–76. pmid:16223715
- 13. Hsiao H, Whitestone J, Kau T-Y, Whisler R, Routley JG, Wilbur M. Sizing firefighters: method and implications. Hum Factors. 2014;56(5):873–910. pmid:25141595
- 14. Christopher L, Rohr-Kirchgraber T, Mark S. The PPE pandemic: sex-related discrepancies of N95 mask fit. EMJ Microbiol Infect Dis. 2021;2(1):57–63.
- 15. McMahon E, Wada K, Dufresne A. Implementing fit testing for N95 filtering facepiece respirators: practical information from a large cohort of hospital workers. Am J Infect Control. 2008;36(4):298–300. pmid:18455051
- 16. Bourgeault IL, James Y, Lawford K, Lundine J. Empowering women leaders in health: a gap analysis of the state of knowledge. Can J Physician Leadersh. 2018;5(2):1.
- 17. Çiriş YC, Ulaşli KH, Tanriverdi FŞ. COVID-19 pandemic and personal protective equipment: Evaluation of equipment comfort and user attitude. Arch Environ Occup Health. 2022;77(1):1–8.
- 18. Farkas LG, Katic MJ, Forrest CR, Alt KW, Bagic I, Baltadjiev G, et al. International anthropometric study of facial morphology in various ethnic groups/races. J Craniofac Surg. 2005;16(4):615–46. pmid:16077306
- 19. Milosevic M, Kishore Biswas R, Innes L, Ng M, Mehmet Darendeliler A, Wong A, et al. P2/N95 filtering facepiece respirators: Results of a large-scale quantitative mask fit testing program in Australian health care workers. Am J Infect Control. 2022;50(5):509–15. pmid:34971710
- 20. Carvalho CYM, Schumacher J, Greig PR, Wong DJN, El-Boghdadly K. Prospective observational study of gender and ethnicity biases in respiratory protective equipment for healthcare workers in the COVID-19 pandemic. BMJ Open. 2021;11(5):e047716.
- 21. Chopra J, Abiakam N, Kim H, Metcalf C, Worsley P, Cheong Y. The influence of gender and ethnicity on facemasks and respiratory protective equipment fit: a systematic review and meta-analysis. BMJ Glob Health. 2021;6(11):e005537. pmid:34764145
- 22. Khairul Hasni NA, Ismail R, Muhamad Robat R, Mohamad N, Suib FA, Pahrol MA, et al. The effect of N95 designs on respirator fit and its associations with gender and facial dimensions. PLoS One. 2023;18(11):e0288105. pmid:38019763
- 23.
Creswell JW, Clark VLP. Designing and conducting mixed methods research. Sage Publications; 2017.
- 24. Tariq S, Woodman J. Using mixed methods in health research. JRSM Short Rep. 2013;4(6):2042533313479197. pmid:23885291
- 25. Healthcare Respiratory Protection Resources, Fit Testing | NPPTL | NIOSH | CDC [Internet]. 2021 [cited 2022 July 6]. Available from: http://www.cdc.gov/niosh/npptl/hospresptoolkit/fittesting.html
- 26. Fit Test FAQs | NPPTL | NIOSH | CDC [Internet]. 2021 [cited 2022 June 27]. Available from: http://www.cdc.gov/niosh/npptl/topics/respirators/disp_part/respsource3fittest.html
- 27. Hospital respiratory protection program toolkit: resources for respirator program administrators. 2022 Apr 6 [cited 2022 June 27]; Available from: http://www.cdc.gov/niosh/docs/2015-117/default.html
- 28. NIOSH Conformity Assessment Interpretation Notice (CA 2019-1011) | NPPTL | NIOSH | CDC [Internet]. 2022 [cited 2022 July 6]. Available from: http://www.cdc.gov/niosh/npptl/resources/pressrel/letters/conformityinterp/CA-2019-1011.html
- 29. Bradshaw C, Atkinson S, Doody O. Employing a qualitative description approach in health care research. Glob Qual Nurs Res. 2017;4:2333393617742282.
- 30. Sandelowski M. Whatever happened to qualitative description? Res Nurs Health. 2000;23(4):334–40. pmid:10940958
- 31. Etikan I, Musa SA, Alkassim RS. Comparison of convenience sampling and purposive sampling. Am J Theor Appl Stat. 2016;5(1):1–4.
- 32. Allua S, Thompson CB. Inferential statistics. Air Med J. 2009;28(4):168–71.
- 33. Slattery EL, Voelker CCJ, Nussenbaum B, Rich JT, Paniello RC, Neely JG. A practical guide to surveys and questionnaires. Otolaryngol Head Neck Surg. 2011;144(6):831–7. pmid:21493322
- 34. Guetterman TC, Fetters MD, Creswell JW. Integrating Quantitative and Qualitative Results in Health Science Mixed Methods Research Through Joint Displays. Ann Fam Med. 2015;13(6):554–61. pmid:26553895
- 35.
Organization WH. Guidance for managing ethical issues in infectious disease outbreaks. World Health Organization; 2016.
- 36. Wardhan R, Brennan MM, Brown HL, Creech TB. Does a Modified Adhesive Respirator Improve the Face Seal for Health Care Workers Who Previously Failed a Fit Test?: A Pilot Study During the Coronavirus Disease 2019 Pandemic. A A Pract. 2020;14(8):e01264. pmid:32643906
- 37. Lee K, Slavcev A, Nicas M. Respiratory protection against Mycobacterium tuberculosis: quantitative fit test outcomes for five type N95 filtering-facepiece respirators. J Occup Environ Hyg. 2004;1(1):22–8. pmid:15202153
- 38. Green S, Gani A, Bailey M, Brown O, Hing CB. Fit-testing of respiratory protective equipment in the UK during the initial response to the COVID-19 pandemic. J Hosp Infect. 2021;113:180–6. pmid:33940089
- 39. Low CS, Ngui SZ, Casey MJ, Vuong C, Afroz A, Sengupta S, et al. Pass rates of four P2/N95 respirators or filtering facepiece respirators in Australian healthcare providers: A prospective observational study. Anaesth Intensive Care. 2023.
- 40. Lin YC, Chen CP. Fit of N95 filtering facepiece respirators influenced by gender, design of facepiece, and activity engaged in use. Occup Environ Med. 2013;70(Suppl 1):A108–A108.
- 41. Wilkinson IJ, Pisaniello D, Ahmad J, Edwards S. Evaluation of a large-scale quantitative respirator-fit testing program for healthcare workers: survey results. Infect Control Hosp Epidemiol. 2010;31(9):918–25. pmid:20658919
- 42. Brazile WJ, Buchan RM, Sandfort DR, Melvin W, Johnson JA, Charney M. Respirator fit and facial dimensions of two minority groups. Appl Occup Environ Hyg. 1998;13(4):233–7.
- 43. Oestenstad RK, Elliott LJ, Beasley TM. The effect of gender and respirator brand on the association of respirator fit with facial dimensions. J Occup Environ Hyg. 2007;4(12):923–30. pmid:17957562
- 44. Characteristics and Labour Market Outcomes of Internationally Educated Health Care Professionals in Canada [Internet]. 2023 [cited 2025 Oct 1]. Available from: https://www.canada.ca/en/health-canada/services/health-care-system/health-human-resources/characteristics-labour-market-outcomes-internationally-educated-health-care-professionals-canada.html
- 45. Health workforce in Canada: Overview | CIHI [Internet]. [cited 2025 Oct 1]. Available from: https://www.cihi.ca/en/health-workforce-in-canada-overview?utm_source=chatgpt.com