Abstract
Background
Insulin, a peptide hormone crucial for diabetes management, necessitates strict storage (2-8oC) to maintain concentration, as per regulatory guidelines (e.g., USP, WHO). Degradation can occur during manufacturing process, and transportation or storage, via heat-induced denaturation and aggregation, compromises its efficacy. In Sub-Saharan Africa, including Tanzania, weak regulatory oversight of imported medicines may compromise insulin quality. Varied findings from existing studies underline the need for local quality assessments.
Methods
This cross-sectional study, conducted from April to July 2024 in Mwanza, Tanzania, evaluated the quality of insulin from eight pharmacies. A convenience sampling approach was employed, with insulin samples purchased as a simulated patient to reflect real-world acquisition. 15 samples, representing seven distinct insulin brands, were collected. High-Performance Liquid Chromatography (HPLC) was utilized to quantify insulin concentration. Additionally, samples were assessed for visual appearance, packaging, labeling, and storage conditions following established pharmacopoeial and quality control standards.
Results
Out of 15 insulin samples, two samples (13.3%) failed to meet the official USP monograph during the assay test. The remaining samples 13 (86.7%) complied with USP standards.
Conclusion
These findings underline significant challenges in ensuring the quality of insulin products. While most samples adhered to USP standards, the issues observed highlight the need for improved quality control measures and robust cold chain management to guarantee the efficacy and reliability of insulin for diabetic patients.
Citation: Kimaro E, Konje ET, Kidenya BR, Mori AT, Kaale E (2025) Quality of insulin obtained from hospital and community pharmacies in Mwanza Tanzania: A cross-sectional study. PLoS One 20(6): e0325366. https://doi.org/10.1371/journal.pone.0325366
Editor: Christophe Curti, Assistance Publique - Hôpitaux de Marseille, FRANCE
Received: January 27, 2025; Accepted: May 12, 2025; Published: June 4, 2025
Copyright: © 2025 Kimaro et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the article and its Supporting information files.
Funding: This research was funded by the Higher Education for Economic Transformation (HEET) Project, supported by the Government of Tanzania.
Competing interests: The authors have declared that no competing interests exist.
Background
Insulin is a polypeptide hormone primarily produced by beta cells in the islets of Langerhans of the pancreas. It plays a crucial role in carbohydrate metabolism, and individuals who cannot produce insulin are unable to regulate their blood glucose levels effectively [1]. Insulin is a life-saving medication for individuals with type 1 diabetes mellitus and is also essential for some patients with type 2 diabetes mellitus who require daily injections to maintain glycemic control [2].
To preserve insulin’s concentration and efficacy, manufacturers and regulatory agencies such as the U.S. Food and Drug Administration (FDA), European Medicines Agency (EMA), and World Health Organization (WHO) recommend that all insulin formulations be stored within a temperature range of 2°C to 8°C (36°F to 46°F) [3]. This temperature range is specified in pharmacopeial monographs, such as the United States Pharmacopeia (USP) and European Pharmacopeia (Ph. Eur.), which outline stability requirements and quality control parameters for insulin storage and distribution [4]. However, in many Low- and Middle-Income Countries (LMICs), including Tanzania, maintaining these optimal storage conditions remains a challenge due to unreliable electricity supply, inadequate refrigeration facilities, and economic constraints [5]. Inadequate storage conditions have been widely recognized as contributors to potential insulin degradation. Nonetheless, an often overlooked but equally important issue is the source and manufacturing quality of insulin products, especially in LMICs where regulatory oversight of imported pharmaceuticals may be limited. Defective products may originate from manufacturers with poor quality control standards, making it difficult to attribute reduced concentration solely to storage conditions.
Insulin stability is affected by temperature fluctuations, direct exposure to light, and mechanical stress due to agitation, all of which can accelerate degradation processes. Degradation mechanisms include chemical degradation (e.g., hydrolysis and deamidation) and physical instability (e.g., fibrillation and precipitation) [6,7]. Regulatory guidelines like USP monograph, European pharmacopeia (Ph. Eur.), and ICH Q5C-stability of biotechnological/Biological products highlight that insulin formulations degrade rapidly at pH values below 5 and above 8, necessitating stringent control over formulation conditions to ensure product stability [8].
Different insulin formulations exhibit varying degrees of stability due to differences in peptide structure, excipients, and manufacturing processes [9]. Regulatory authorities require stability testing for each insulin formulation to establish shelf-life specifications under both recommended and stressed conditions. The International Conference on Harmonisation (ICH) guideline Q1A (R2) provides a framework for evaluating stability and defining appropriate storage conditions [10]. However, limited data exist on the quality of insulin formulations available in sub-Saharan Africa, necessitating region-specific studies to assess potential degradation risks.
In many parts of sub-Saharan Africa, including Tanzania, weak supply chain infrastructure coupled with limited regulatory capacity contributes to the importation of substandard medicines. Studies have shown that temperature excursions beyond the recommended range during transportation and storage can lead to chemical and physical degradation, reducing insulin’s content and clinical effectiveness [6]. Moreover, regulatory oversight of manufacturing facilities that supply imported medicines to these regions remains limited, with insufficient enforcement of pharmacovigilance measures to ensure insulin quality throughout the supply chain.
Several studies across Africa have highlighted significant concerns regarding insulin quality defects, primarily due to improper storage conditions and handling practices. For instance, research conducted in Ghana and Nigeria found that insulin vials stored in health facilities often exceeded recommended temperature limits, raising concerns about compromised potency [11,12]. In LMICs, evidence regarding insulin quality is scarce. One study conducted in Kenya found no significant change in insulin content after exposure to simulated laboratory conditions [6]. To address this gap and ensure insulin quality assurance in Tanzania, our study evaluated the quality of insulin obtained from community and hospital pharmacies in Mwanza, Tanzania.
Methods
Study design, duration and setting
This cross-sectional, laboratory based study was conducted from April to July 2024, in Mwanza city. Mwanza’s proximity to four international borders [Kenya, Uganda, Rwanda, and Burundi} underlines its significance for this study because pharmaceutical products including insulin can easily move across the porous borders. The presence of the Tanzania Medicines and Medical Devices Authority (TMDA) laboratory facility in Mwanza’s lake zone also made it suitable location for conducting this research. TMDA is classified as a Level 3 regulatory authority according to the World Health Organization (WHO) Global Benchmarking Tool (GBT) standards. A Level 3 classification indicates that the regulatory system has reached a level of maturity where it functions well and complies with most international standards for overseeing medical products. It also signifies that TMDA is capable of ensuring the safety, quality, and efficacy of medicines and medical devices.
Sample size, sampling procedure, and selection criteria
A total of 15 human insulin samples, representing seven different brands, were collected from seven community pharmacies and one hospital pharmacy. A convenient sampling technique was employed to select pharmacies with high patient traffic and significant insulin sales. The insulin samples were obtained by purchasing them as regular customers without prior notification to the pharmacies. This approach ensured the assessment of insulin quality as it is supplied to patients. Similar sampling methods have been suggested in pharmaceutical surveillance studies [13,14]. We included samples that had complete labeling information and were within their shelf life. Insulin products in poor condition, such as those with leakage were excluded from the study.
Pharmacy storage condition
The study utilized bluetooth temperature data logger device (LogTag Recorder Ltd, LogTag TRED30−7, New Zealand). Key specifications include: Measurement Range: −20°C to +40°C, with an accuracy of ±0.5°C. Battery Life. Designed for continuous operation for over 30 days, aligning with the study duration. Storage Capacity: Internal memory capable of storing approximately 45,000 data points, recorded at 15-minute intervals.
Deployment and removal protocol.
Placement: Pharmacists working in the pharmacies were requested to position the data loggers near their insulin storage locations, such as the refrigerator.
Monitoring Duration: Each device remained in place for 30 days to capture continuous temperature variations.
Retrieval: After the monitoring period, pharmacists returned the loggers to the research assistant. Data extraction was performed using Credo, which facilitated the transfer of recorded data to a computer equipped with the appropriate software for analysis.
Data mining and processing workflow.
Data Transmission: The Credo system was used to retrieve data from the loggers and transfer it to a dedicated computer for analysis.
Data Analysis: Temperature profiles were evaluated for deviations from recommended storage conditions: Refrigeration: 2°C to 8°C while for the room temperature: Below 30°C
Material and reagents
Reagents that were used were all HPLC grade; Human insulin CRS batch 5 (67081 Strasbourg (France), Water (Sigma-Aldrich, Milli-Q water purification system, United States), orthophosphoric acid and sodium anhydrous sulphate (Sigma-Aldrich, analytical grade, United States), Acetonitrile (Sigma-Aldrich, analytical grade, United States). Apparatus that were used include; measuring cylinder (Pyrex Measuring Cylinder (Make: Pyrex, United States), volumetric flask (Class A Volumetric Flask (Make: Duran, Germany), beaker (Beaker: Pyrex Beaker (Make: Pyrex, United States), thermometer (H–B Instrument Thermometer (Make: H–B Instrument, United States), analytical scale (Mettler Toledo Analytical Balance (Make: Mettler Toledo, Switzerland).
Equipment’s
HPLC machine (Model: Agilent 1260 Infinity II HPLC System: Agilent Technologies, United States) which was used for quantification of human insulin from samples collected. PH meter (Mettler Toledo Seven Compact S220 pH Meter Make: Mettler Toledo, Switzerland) for measuring PH, sonicator (Branson SFX150 Sonifier Make: Branson, United States) for sonication. Bluetooth Temperature Data Logger Device (LogTag Recorder Ltd, LogTag TRED30−7, New Zealand).
System suitability test and identification test
System suitability solution of 1.5 mg/ml of human insulin in 0.01 N hydrochloric acid was prepared and allowed to stand at room temperature for Not less than three days ([NLT 3 days) to obtain a solution containing NLT 5% of A-21 desamido insulin human. The prepared solution was injected to HPLC and the mobile phase was prepared according to the USP monograph. The system suitability requirements are: Peak resolution NLT 2.0 between insulin human and A-21 desamido insulin human, system suitability solution. Tailing factor not more than (NMT 1.8). The retention time of the major peak of the sample solution corresponds to that of the standard solution, as obtained in the assay it will confirm the identity.
Assay test
An assay test is an analytical method used to assess the purity, and content of a particular substance within a sample. It involves analyzing the sample’s properties, such as its chemical composition, and comparing them to a known standard to ensure quality and adherence to established specifications. In the current study we determined the insulin content. The analytical procedure for content determination was carried out according to the USP monograph [4].
Results
Pharmacy storage condition
The study found that all wholesalers failed to follow cold chain transport guidelines, with no use of temperature loggers during receipt or distribution. Some also sourced insulin from street vendors, compromising quality. Temperature monitoring was conducted in eight pharmacies during period of data collection. Findings showed that during the study period, temperatures remained within the recommended range, with a mean of the Mean Kinetic Temperature of 6.052 (minimum 5.053, maximum 8.348). Mean Kinetic Temperature (MKT) was calculated to confirm that recorded temperatures were consistently within the acceptable limits throughout the data collection period.
System suitability
The percentage Relative Standard Deviation (%RSD) values for peak area and retention time were within 2% as shown in Table 1 below, indicating the system’s suitability. The efficiency of the column separation, expressed by a resolution of NLT 2.0, and the peak symmetry, expressed by a tailing factor of 1.10 ± 1.1% (mean ± % RSD), also confirmed the system’s suitability.
Fifteen different insulin samples were used to assess the quality of human insulin as shown in Table 2. All brands were registered
Identification of insulin in products
The retention time of the major peak of the sample ranges from 12.8 minutes to 14.0 minutes, with a mean retention time of 13.1 minutes and a percentage relative standard deviation (%RSD) of 1.4%. This corresponds to the retention time of the reference standard solution, which is 13.7 minutes with an RSD of 1.4%. Fig 1 confirms the presence of human insulin in the injected samples, as evidenced by peaks corresponding to the insulin standard. In contrast, Fig 2 shows no detectable human insulin, suggesting either degradation or absence of the compound in those samples. Each set of figures includes a chromatographic peak for the reference standard (Figs 1a and 2b), which serves to confirm the identity of insulin in the samples. The corresponding sample peaks are used to both verify the presence of insulin and determine its concentration by comparison with the standard.
Insulin concentration in products
Out of the 15 samples, 2 (13.3%) did not comply with USP specifications (not less than 27.5 mg) regarding the human insulin concentration in the vials, as shown in Table 2 above. The % RSD for reference standard was 1.1%
Discussion
The temperature storage conditions for the insulin samples during the study period were satisfactory. Therefore, the storage temperatures in the pharmacy premises do not appear to explain the out-of-specification results observed in two samples (13.3%).
In the current study we found human insulin samples matched the reference standard solution in terms of retention time (13 minutes), with tailing factors not exceeding 1.8 and peak resolution not less than 2.0. These results indicate that the method used for detection and assessing insulin concentration in the vials was suitable for separating human insulin and A-21 desamido insulin. These findings are consistent with another study that determined the identification of human insulin in various pharmaceutical products, where the retention time was found to range between 14 minutes and 20 minutes [15,16].
Of the 2 (13.3%) non-compliant or substandard human insulin samples as shown in Table 2. This discrepancy could be attributed to poor manufacturing processes or poor handling during transportation. Manufacturing of large molecules like proteins (insulin) is very complex with many parameters that are difficult to control. Manufacturers of large molecules face significant challenges due to batch-to-batch variability, which can lead to final products that do not meet minimum quality standards [17,18]. The World Health Organization, U.S., and EU have developed guidelines for the distribution of cold chain products like insulin, placing responsibility on manufacturers, regulatory authorities, and wholesalers to ensure proper transport conditions [3].
Out of 15 human insulin samples tested, two were substandard (13.3%) failed to meet the official USP monograph standards in the assay test. This non-compliance likely stems from cold chain distribution challenges common in Sub-Saharan Africa, including Tanzania, as well as potential manufacturing shortcomings. These findings underline the urgent need to strengthen quality control and distribution systems for insulin products.
The remaining human insulin samples comply with official USP standards, meeting the acceptance criteria of not less than (NLT) 27.5 mg and concentration range of 95%−105% [4]. Out of 15 human insulin samples, 13 (13.3%) comply with the official USP standards as shown in the Table 2 above, consistent with findings from other studies [6,19,20]. The chromatograms in Figs 1 and 2 indicate that the human insulin samples (Insu 009 & 010) were substandard, likely due to poor formulation during manufacturing process or environmental factors such as temperature, light, and agitation during transportation.
Insulin monomers are highly susceptible to mechanical agitation during manufacturing, transportation, and handling. Agitation induces partial unfolding of the insulin structure, exposing hydrophobic regions of the peptide that are usually buried within the native conformation [21]. These exposed hydrophobic regions facilitate the self-association of insulin monomers, leading to aggregation. Over time, these aggregates can evolve into insoluble amyloid fibrils through a nucleation-dependent process [21]. This fibril formation not only reduces the active concentration of insulin in the vials but also compromises its therapeutic efficacy [22]. Furthermore, injecting insulin containing aggregates or fibrils can contribute to injection-site complications, including lipohypertrophy, lipoatrophy, and insulin-derived amyloidosis, while also impairing glycemic control [22]. The main limitation of this study is the lack of assessment for insulin fibrils in the non-compliant human insulin vials. We recommend further research on non-compliant insulin samples [23].
Policy implications for insulin quality control in Tanzania
To address insulin quality issues in Tanzania, it is essential to strengthen quality control measures at all stages of the supply chain, including rigorous testing to ensure that insulin products meet active human insulin standards. Enhancing manufacturing processes and improving cold chain distribution infrastructure are crucial for maintaining insulin efficacy. Regular training programs for personnel working at Tanzania Medicine and Medical Device Authority (TMDA) so as to be identify sub-standard pharmaceutical products available in Tanzanian market, coupled with stricter regulatory oversight and enforcement, and are needed to uphold standards. Public awareness campaigns should educate stakeholders on proper insulin handling and storage, while collaboration with international partners can help to adopt best practices. Encouraging ongoing research and continuous improvement will ensure that policies and procedures remain effective, ultimately improving insulin quality and patient outcomes in Tanzania. Furthermore, WHO encourages integrating the supply chain for storing, handling, and distributing temperature-sensitive vaccines and non-vaccine [23].
Conclusion
The study reveals significant insights into the quality of insulin products, highlighting that while most samples meet the official USP standards, a few do not, reflecting potential issues in manufacturing and distribution. Specifically, two samples lacked active human insulin, which may be due to inadequate manufacturing processes or improper storage during transportation.
Acknowledgments
The authors extend their thanks to the Catholic University of Health and Allied Sciences (CUHAS) and the Higher Education and Economic Transformation (HEET) project for funding this study, as well as to the Tanzania Medicine and Medical Devices Authority (TMDA) for their support with laboratory work. We also appreciate the expert reviewers for their valuable feedback, which greatly improved the quality of this article.
References
- 1. Quianzon CC, Cheikh I. History of insulin. J Community Hosp Intern Med Perspect. 2012;2(2). pmid:23882369
- 2. IDF Diabetes Atlas. (cited 13th June 2024). Available from: https://diabetesatlas.org/.
- 3. Heinemann L, Braune K, Carter A, Zayani A, Krämer LA. Insulin storage: a critical reappraisal. J Diabetes Sci Technol. 2021;15(1):147–59. pmid:31994414
- 4.
Monograph U. USP-NF insulin injection. 2020.
- 5. Ringo S, Mugoyela V, Kaale E, Sempombe J. Assessment of medicines cold chain storage conformity with the world health organization requirements in health facilities in Tanzania. Pharmacol Pharmacy. 2017;8 (10):325–38.
- 6. Kaufmann B, Boulle P, Berthou F, Fournier M, Beran D, Ciglenecki I, et al. Heat-stability study of various insulin types in tropical temperature conditions: New insights towards improving diabetes care. PLoS One. 2021;16(2):e0245372. pmid:33534816
- 7. Brange J, Langkjaer L. Chemical stability of insulin. 3. Influence of excipients, formulation, and pH. Acta Pharm Nord. 1992;4(3):149–58. pmid:1418641
- 8.
Davies JG, Gao D, Kim Y, Harris R, Cash P, Schofield T, et al. ICH Q5C stability testing of biotechnological. biological products. 2017:345.
- 9. Teska BM, Alarcón J, Pettis RJ, Randolph TW, Carpenter JF. Effects of phenol and meta-cresol depletion on insulin analog stability at physiological temperature. J Pharm Sci. 2014;103(8):2255–67. pmid:24909933
- 10.
Stability testing ofnew drug substances and products q1a (r2). International conference on harmonisation of technical requirements for registration of pharmaceuticals for human USE; 2003.
- 11. Puepet FH, Mijinyawa BB, Akogu I. Insulin storage by patients with diabetes mellitus in Jos, Nigeria. J Med Trop. 2007;9(1).
- 12. Asamoah A, Ebu Enyan NI, Diji AK-A, Domfeh C. Cold chain management by healthcare providers at a district in Ghana: a mixed methods study. Biomed Res Int. 2021;2021:7559984. pmid:34557551
- 13.
World Health Organization. Guidelines on the conduct of surveys of the quality of medicines. World Health Organization; 2015.
- 14. Newton PN, Lee SJ, Goodman C, Fernández FM, Yeung S, Phanouvong S, et al. Guidelines for field surveys of the quality of medicines: a proposal. PLoS Med. 2009;6(3):e52. pmid:19320538
- 15. Yilmaz B, Kadioglu Y. Development and validation of HPLC method for determination of human insulin in pharmaceutical preparation. Int J Pharmaceutical Sci Rev Res. 2010;2(2):40–3.
- 16. Legg KM, Labay LM, Aiken SS, Logan BK. Validation of a fully automated immunoaffinity workflow for the detection and quantification of insulin analogs by LC-MS-MS in postmortem vitreous humor. J Anal Toxicol. 2019;43(7):505–11. pmid:30926990
- 17. Vulto AG, Jaquez OA. The process defines the product: what really matters in biosimilar design and production?. Rheumatology (Oxford). 2017;56(suppl_4):iv14–29. pmid:28903544
- 18. Kuhlmann MK, Schmidt A. Production and manufacturing of biosimilar insulins: implications for patients, physicians, and health care systems. Biosimilars. 2014;:45–58.
- 19. Lorbetskie B, Bigelow S, Walrond L, Klein AV, Loo SM, Green N, et al. Regulatory verification by Health Canada of content in recombinant human insulin, human insulin analog, and porcine insulin drug products in the Canadian market using validated pharmacopoeial methods over nonvalidated approaches. J Diabetes Sci Technol. 2023.
- 20. Garrett TJ, Atkinson P, Quinlivan EP, Ang L, Hirsch IB, Laffel L, et al. Commercially available insulin products demonstrate stability throughout the cold supply chain across the U.S. Diabetes Care. 2020;43(6):1360–2. pmid:32273273
- 21. Wu H, Movafaghi S, Francino Urdániz IM, Rowe TM, Goodwin A, Randolph TW. Insulin fibril formation caused by mechanical shock and cavitation. J Phys Chem B. 2021;125(29):8021–7. pmid:34260251
- 22. Rosetti B, Marchesan S. Peptide inhibitors of insulin fibrillation: current and future challenges. Int J Mol Sci. 2023;24(2):1306. pmid:36674821
- 23. Organization WH. Temperature-sensitive health products in the expanded programme on immunization cold chain: a WHO-UNICEF joint statement encouraging greater health commodity supply chain integration for temperature-sensitive pharmaceuticals where appropriate. 2020. https://www.who.int/publications/i/item/temperature-sensitive-health-products-in-the-expanded-programme-on-immunization-cold-chain