Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

The bacterial burden on computer keyboards across selected university facilities at Liverpool John Moores University, City Campus, Byrom Street, Liverpool

Abstract

Background

Bacterial burden within universities is important to investigate due to the high footfall of both students and staff, who may bring contaminants from body fluids, food, and the environment. These bacterial contaminants may be harmful to both immunocompromised and immunocompetent individuals. A focus on online resources and communication with workplaces and universities bring an important issue of computer keyboards and mice becoming potential reservoirs for such bacteria.This study aimed to investigate the presence of bacteria on computer keyboards and mice across the Liverpool John Moores University campus by detecting the presence of bacterial growth, identifying these bacteria and the role of disinfection in lowering the bacterial counts and changing their diversity.

Materials and method

A total of 478 pre- and post-treatment swab samples were taken using sterile cotton swabs moistened in sterile nutrient broth (Thermo Scientific™ Oxoid™) from both the keyboards and mice of facilities across the university campus were cultured at 37°C on blood agar plates. A total period of 30 minutes elapsed between first sampling (pre-treatment) and disinfection before the second sampling (post-treatment). Identification of isolated bacterial species was done with Matrix-Assisted Laser Desorption/Ionization Time-of-Flight (MALDI-TOF) mass spectrometry according to protocol by BioMérieux VITEK® MS prime.

Results

One hundred and fifty-four (64.4%) of pre-treatment and Forty-nine (20.5%) of post-treatment cultures showed microbial growth, which were identified as various species of Gram-positive cocci, Gram positive bacilli and Gram-negative cocci.

Discussion

Across the Liverpool John Moores campus computer keyboards and mice were found to be contaminated with many bacteria, all of which were identified as opportunistic and therefore are not likely to cause harm to healthy individuals. However, there is a greater risk of infection to immunocompromised individuals, which could lead to co-morbidities.

Introduction

The bacterial burden on surfaces has been researched for many years in hospitals with an effort to reduce bacterial contamination and infections leading to co-morbidities [1,2,3]. Assessment of the presence of bacteria should be applied to universities and workplaces to protect students and staff from harmful pathogens they may be unknowingly spreading [4,5,6,7]. Bacteria can be spread via direct and indirect contact with infected droplets, airborne particles and fomites, with many bacterial species able to survive on inanimate surfaces for weeks to even months [8,9].

Due to increased online presence within universities such as the utilization of online resources for announcements, accessing learning content, contacting staff/students and handing in/marking work, computers have become one of the most used interfaces for both students and staff. Computer keyboards and mice have the most contact with a person’s hands, with average keyboards having over 100 keys and many grooves. This increases the surface area and creates difficult to reach recesses which results in keyboards being problematic and time consuming to thoroughly clean, therefore they may harbour bacterial pathogens [4]. It is important to consider that bacteria present may be opportunistic pathogens meaning they are not harmful to immunocompetent individuals, however, may pose a risk of infection to immunosuppressed individuals.

This study will assess the bacterial burden of multi-user computer keyboards and mice across the Liverpool John Moores city campus (LJMU), identify the bacterial species grown from the samples and discuss whether disinfection using a 70% isopropyl alcohol wipe (PDI Sani-Cloth®) is sufficient to reduce the presence of bacteria within the university campus.

Methods

Computer keyboards and mice were sampled from across the Liverpool John Moores University’s City campus with a total of 478 swabs taken between 9th −20th January 2023–8th −19th January 2024 across different facilities on LJMU campus (see Table 1). Initially computer keyboard and mouse samples were taken with a sterile cotton swab (SLS® Select Swab Woodstick with Cotton Tip Single in Peel Pouch), which was then capped and given an identification number denoting the sample was part of the pre-treatment group. During sampling, the mouse was swabbed first because this is the part of the computer that has the most contact with our hands. Then the keyboard was sampled with the same cotton swab by rubbing it along the top of the key. Lastly, the swab was dragged along the grooves of the keyboard to ensure the whole keyboard was thoroughly sampled. Immediately, a second sample was taken from the computer using a new swab after the keyboard and mouse had been disinfected with a 70% v/v isopropyl alcohol wipe (PDI Sani-Cloth®). A total period of 30 minutes elapsed between first sampling and disinfection before the second sampling (post-treatment) This sample was then capped and given identification number denoting it was a post-treatment sample. 239 computer samples were taken (see Table 1), with computers in various environments around campus including the library (69 computers), lecture theatres (14 computers), IT offices (80 computers), IT Suites (70 computers), communal areas (6 computers). The swabs were transferred to a laboratory where they were inoculated onto blood agar plates (Thermo Scientific™) and incubated aerobically overnight at 37°C [10, 11, 12] using Thermo Scientific™ incubator. For the initial stages of the investigation colony growth, gram staining [13,14,15] and morphology assessment was performed to group the bacterial species found. A selection of these samples was sub cultured and incubated overnight using Thermo Scientific™ incubator prior to analysis using MALDI-TOF spectrometry according to protocol by BioMérieux VITEK® MS prime to identify bacterial species [16,17,18] using α-Cyano-4-hydroxycinnamic acid (CHCA) as a matrix [19]. The BioMérieux VITEK® MS prime algorithm enables accurate discrimination of all species identified with performance ranging from 98 to 100%.

thumbnail
Table 1. Resut showing the colonial growth from pre- and post-treatment cultures.

https://doi.org/10.1371/journal.pone.0324977.t001

Results

Growth on the blood agar plates demonstrated One hundred and fifty-four (64.4%) of pre-treatment samples (A) had microbial colony growth, decreasing to Forty-nine (20.5%) among the post-treatment samples (B) group as can be seen in Fig 1.

thumbnail
Fig 1. The percentage growth and no growth from cultures from pre and post treatment samples.

https://doi.org/10.1371/journal.pone.0324977.g001

The distribution of this growth indicated that library and IT suites samples produced the greatest number of samples with growth, 53 and 69 samples respectively as can be seen in Fig 2.

thumbnail
Fig 2. The bacterial growth distribution for pre-treatment samples across the locations.

https://doi.org/10.1371/journal.pone.0324977.g002

Further investigation, using Gram staining and MALDI-TOF MS (see Table 1) indicated a high proportion of the bacterial growth present was identified as Gram-positive cocci (GPC) species such as Staphylococcus albus, S. epidermidis, S. hominis, S. saprophyticus, S. warneri and Micrococcus luteus, with ninety-two (71%) of pre-treatment and twenty-nine (78%) of post-treatment growth resulting from GPC species (see Tables 1 and 2).

thumbnail
Table 2. Identification of bacterial isolates using MALDI-TOF BioMérieux VITEK® MS prime.

https://doi.org/10.1371/journal.pone.0324977.t002

Gram-positive bacillus (GPB) bacteria were also isolated from samples from both pre- and post- treatment swabs, with thirty-five (27%) of pre-treatment and eight (23%) of post-treatment growth being from GPB species. Examples of GPB species found include Bacillus licheniformis, B. subtilis var. amyloliquefaciens and B. cereus, which are usually present in soil [10]. Lastly, two (1.6%) of pre-treatment growth was Gram-negative cocci (GNC) species identified as Enhydrobacter aerosaccus and Moraxella osloensis as shown in Table 2.

Discussion

Hand hygiene is the primary action to prevent infection and reduce the spread of multi-resistant organisms [20]. Numerous studies have indicated that computer keyboards (and mice) can become contaminated with pathogenic bacteria. As with health care settings, computer keyboards in educational institutions may act a mechanism for the transmission of pathogenic bacteria. Previous studies have demonstrated that other shared communication equipment, such as telephones, can also become contaminated by potentially pathogenic microorganisms, often members of the human microbiota [21,22].

Overall, the results showed that there were bacteria present on the computer keyboards and mice with 64.4% of the pre-treatment sample having colonial growth. This result is consistent with studies from UK and India [23,24]. It was expected that this would be higher considering the high footfall of both students and staff through the area where the samples were taken. Some factors could account for samples not showing microbial growth due to inability to provide anaerobic conditions. The samples were subject to aerobic conditions, where only species supported in this environment would grow. Therefore, if a second culture had been incubated anaerobically or in microaerophilic conditions there may have been a higher percentage of viable cultures. Another factor to consider is lasting vigilance of hygiene standards from the COVID-19 pandemic, in addition to continued presence of hand sanitiser and cleaning products available around the university campus.

All the bacteria identified from samples are commonly found as part of the normal human flora of the skin, mucus membranes and respiratory tract. These species identified are all opportunistic pathogens, which do not usually cause disease in healthy individuals however the presence of these microorganisms poses a greater risk to individuals who are immunosuppressed or compromised [4]. The GPC species found are a part of normal human microbiota of the skin and nasal passage; however, these are also opportunistic pathogens that are associated with many diseases and co-morbidities especially in individuals that are immunosuppressed [25]. It was expected that these species would be present; however, it is surprising that pathogenic bacteria were not isolated due to the number and variety of individuals using the facilities.

This percentage of no growth increased from 35.6% in the pre-treatment group to 79.5% in the post-treatment group as shown in (Fig 3), suggesting that the bacteria burden was decreased with the use of 70% isopropyl alcohol wipes confirming the effectiveness of the intervention.

thumbnail
Fig 3. The bacterial growth distribution for post-treatment samples across the locations.

https://doi.org/10.1371/journal.pone.0324977.g003

Further research with a larger number of samples and a wider sampling area including a collaborative effort across different universities should be considered. Improvement to the method should be considered including the use of multiple different selective and differential agar plates to promote the growth of more varied bacteria [10,26]. Incubating a repeat sample in anaerobic conditions could help to assess the growth of different species of bacteria that may be present.

Conclusion

This study shows that bacterial contamination of computer mice and computer keyboards is prevalent across different facilities in the university. The commonest bacteria are commensal skin organisms. The study also demonstrates that Gram positive bacteria are mostly isolated from the computer mice and computer keyboards, and a few Gram-negative bacteria. The study emphasises the importance of adequate decontamination procedures using swipe (disinfectant) with a drastic reduction in the number of bacteria isolated post-treatment. We strongly recommend from the outcomes of the study that methods of disinfecting the computer mice and computer keyboards should be undertaken by every user of the computer before and after the usage of the computer mice and the computer keyboards. These approaches if undertaken properly will reduce to the barest minimum the bacterial burden on the University computer mice and computer keyboards.

Supporting information

S1 Table. Minimal data set-MALDI-TOF Results.

https://doi.org/10.1371/journal.pone.0324977.s001

(TIF)

References

  1. 1. Costa DM, Johani K, Melo DS, Lopes LKO, Lopes Lima LKO, Tipple AFV, et al. Biofilm contamination of high-touched surfaces in intensive care units: epidemiology and potential impacts. Lett Appl Microbiol. 2019;68(4):269–76. pmid:30758060
  2. 2. Messina G, Ceriale E, Lenzi D, Burgassi S, Azzolini E, Manzi P. Environmental contaminants in hospital settings and progress in disinfecting techniques. Biomed Res Int. 2013;2013:429780. pmid:24286078
  3. 3. Pal S, Juyal D, Adekhandi S, Sharma M, Prakash R, Sharma N, et al. Mobile phones: Reservoirs for the transmission of nosocomial pathogens. Adv Biomed Res. 2015;4:144. pmid:26322292
  4. 4. Koscova J, Hurnikova Z, Pistl J. Degree of Bacterial Contamination of Mobile Phone and Computer Keyboard Surfaces and Efficacy of Disinfection with Chlorhexidine Digluconate and Triclosan to Its Reduction. Int J Environ Res Public Health. 2018;15(10):2238. pmid:30322055
  5. 5. Al-Ghamdi AK, Abdelmalek SMA, Ashshi AM, Faidah H, Shukri H, Jiman-Fatani AA. Bacterial contamination of computer keyboards and mice, elevator buttons and shopping carts. African Journal of Microbiology Research. 2011;5(23):3998–4003.
  6. 6. Lagier JC, Edouard S, Pagnier I, Mediannikov O, Drancourt M, Raoult D. Current and past strategies for bacterial culture in clinical microbiology. Clin Microbiol. 2023. Rev. 2015;28:208–36.
  7. 7. Lutz JK, Crawford J, Hoet AE, Wilkins JR, Lee J. Comparative performance of contact plates, electrostatic wipes, swabs and a novel sampling device for the. detection of Staphylococcus aureus on environmental surfaces. J Appl. 2013;115:171–8. 2023 October 1.
  8. 8. Kramer A, Schwebke I, Kampf G. How long do nosocomial pathogens persist on inanimate surfaces? A systematic review. BMC Infect Dis. 2006;6:130. pmid:16914034
  9. 9. Widmer FC, Frei R, Romanyuk A, Tschudin Sutter S, Widmer AF. Overall bioburden by total colony count does not predict the presence of pathogens with high clinical relevance in hospital and community environments. J Hosp Infect. 2019;101(2):240–4. pmid:30500387
  10. 10. Anderson G, Palombo EA. Microbial contamination of computer keyboards in a university setting. Am J Infect Control. 2009;37(6):507–9. pmid:19233511
  11. 11. Beveridge TJ. Mechanism of gram variability in select bacteria. J Bacteriol. 1990;172(3):1609–20. pmid:1689718
  12. 12. O’Toole GA. Classic spotlight: How the gram stain works. J Bacteriol. 2023;12. 2016;198(23):3128.
  13. 13. Cantey JB, Doern CD. A Defective and Imperfect” Method: H. Christian Gram and the History of the Gram Stain. Pediatr Infect Dis J. 2015;34(8):848. pmid:25966918
  14. 14. Baillie S, Ireland K, Warwick S, Wareham D, Wilks M. Matrix-assisted laser desorption/ionisation-time of flight mass spectrometry: rapid identification of bacteria isolated from patients with cystic fibrosis. Br J Biomed Sci. 2013;70(4):144–8. pmid:24400425
  15. 15. Bizzini A, Greub G. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry, a revolution in clinical microbial identification. Clin Microbiol Infect. 2010;16:1614–9.
  16. 16. Rabuza U, Šostar-Turk S, Fijan S. Efficiency of four sampling methods used to detect two common nosocomial pathogens on textiles. Textile Research Journal. 2012;82(20):2099–105.
  17. 17. Hogan PG, Burnham C-AD, Singh LN, Patrick CE, Lukas JC, Wang JW, et al. Evaluation of Environmental Sampling Methods for Detection of Staphylococcus aureus on Fomites. Ann Public Health Res. 2015;2(1):1013. pmid:25893222
  18. 18. Afle FCD, Agbankpe AJ, Johnson RC, Houngbegnon O, Houssou SC. Bankole HS. Healthcare-associated infections: bacteriological characterization of the Hospital surfaces in the University Hospital of Abomey-Calavi/So-Ava in South Benin, West Africa. BMC Infect Dis. 2019;19. http://example.com/hospital-surfaces-abomey-calavi
  19. 19. Singhal N, Kumar M, Kanaujia PK, Virdi JS. MALDI-TOF mass spectrometry: an emerging technology for microbial identification and diagnosis. Front Microbiol. 2015;6:791. pmid:26300860
  20. 20. WHO. WHO guideline on hand hygiene in health care (Advanced Draft). World Alliance for patient safety. 2006. https://apps.who.int/iris/bitstream/handle/10665/69323/WHO_EIP_SPO_QPS_05.2.REV.1_eng.pdf
  21. 21. Rafferty KM, Pancoast SJ. Brief report: bacteriological sampling of telephones and other hospital staff hand-contact objects. Infect Control. 1984;5(11):533–5. pmid:6568216
  22. 22. Ferdinandus J, Hensckhe K, Palombo EA. Isolation of pathogenic bacteria and opportunistic pathogens from public telephones. Environ Health. 2001;1:74.
  23. 23. Suchitra JB, Lakshmi Devi N. Impact of education on knowledge, attitudes and practices among various categories of health care workers on nosocomial infections. Indian J Med Microbiol. 2007;25(3):181–7. pmid:17901633
  24. 24. Randle J, Clarke M, Storr J. Hand hygiene compliance in healthcare workers. J Hosp Infect. 2006;64(3):205–9. pmid:16893593
  25. 25. Bomar L, Brugger SD, Lemon KP. Bacterial microbiota of the nasal passages across the span of human life. Current Opinion in Microbiology. 2017;41:8.
  26. 26. Cloutman-Green E, D’Arcy N, Spratt DA, Hartley JC, Klein N. How clean is clean – is a new microbiology standard required?. Am J Infect Control. 2014;42. 1002–3.