Figures
Abstract
Shiga toxin-producing Escherichia coli (STEC) is causing outbreaks worldwide and a rapid detection method is urgently needed. Loop-mediated isothermal amplification (LAMP) has attracted attention in the development of pathogen detection methods; however, current methods for the detection of LAMP amplicon suffer some drawbacks. In this study, we designed a new LAMP method by incorporating peroxidase-mimicking G-quadruplex DNAzyme for a simple colorimetric detection of the LAMP amplicon. As the new method produces LAMP amplicon containing two DNAzyme molecules per amplification unit, the method was termed colorimetric Dual DNAzyme LAMP (cDDLAMP). cDDLAMP was developed targeting 3 common STEC’s virulence genes (stx1, stx2, and eae) that are associated with serious human illnesses such hemorrhagic colitis and hemolytic-uremic syndrome. Immunomagnetic enrichment was used for specific, ultrasensitive, and fast detection of STEC in food samples (leafy vegetables and milk). The sensitivity of cDDLAMP ranged from 1–100 CFU/mL in pure culture to 100–103 CFU/mL in spiked milk, and 104–109 CFU/25g of lettuce. No cross-reaction with other generic E. coli strains and non-E. coli bacteria was observed. The color signal could be observed by the naked eye or analyzed by either UV–Vis spectra or smartphone platforms. Therefore, the cDDLAMP assay is a cost-effective method for detecting STEC strains without expensive machines or extraction methods.
Citation: Sewid AH, Ramos JH, Dylewski HC, Castro GI, D’Souza DH, Eda S (2025) Colorimetric dual DNAzyme reaction triggered by loop-mediated isothermal amplification for the visual detection of Shiga toxin-producing Escherichia coli in food matrices. PLoS ONE 20(4): e0320393. https://doi.org/10.1371/journal.pone.0320393
Editor: Shengqian Sun, Yantai Institute of Technology, CHINA
Received: October 22, 2024; Accepted: February 17, 2025; Published: April 23, 2025
Copyright: © 2025 Sewid et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the manuscript and its Supporting Information files.
Funding: SE, University of Tennessee Institute of Agriculture UT AgResearch, AgResearch Seed Grant, https://agresearch.tennessee.edu/, The funder did not play any role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Competing interests: The authors declare that the research was conducted in the absence of any competing interests.
Introduction
Shiga toxin-producing Escherichia coli (STEC) is a significant cause of foodborne illnesses in the United States [1,2], with E. coli O157:H7 accounting for a substantial portion of cases and deaths [3–6]. Non-O157 STEC strains“ are also increasingly recognized for their clinical and economic impact [7–10].
Detecting STEC is challenging due to the low infectious dose [7,11]. Conventional culture-based methods, such as sorbitol-MacConkey agar, are time-consuming, labor-intensive, and non-specific for non-O157 STEC [12], even with chromogenic agars designed to differentiate non-O157 STEC from generic E. coli. Notably, 29.8% of STEC cases could not be cultured on MacConkey or CHROMagar STEC, highlighting limitations compared to PCR targeting the stx gene [13]. Quantitative polymerase chain reaction (qPCR) offers improved sensitivity and specificity with shorter testing time [14,15] but is not suitable for point-of-care (POC) use due to their complexity and cost.
Recently, loop-mediated isothermal amplification (LAMP), has emerged as a promising alternative for on-site diagnosis [16,17] offering high sensitivity, and tolerance to inhibitors in samples [17], which eliminates the need for DNA extraction kits [18,19].
Despite its potential, current LAMP assays for STEC detection [20–24] require expensive and/or sophisticated machines for real-time monitoring of turbidity or fluorescence signals [16], limiting their practicality for the use in resource-limited settings. Alternative end-point colorimetric LAMP designs were recently used for naked-eye detection of E. coli O157:H7 based on either pH-sensitive (phenol red) [25,26] or DNA-intercalating dyes (malachite green) [27]. However, these dyes are unsuitable for biological samples and require specific nucleic acid extraction kits because these dyes can trigger a color change without successful amplification, leading to false-positive results under certain conditions, such as pH fluctuations or the presence of other reactive components in the sample [28,29].
Short single-stranded DNA molecules with peroxidase-mimicking activity, collectively known named as G-quadruplex DNAzymes (simply called “DNAzyme” in this paper), have been reported to produce a stable and colored radical ion in the presence of H2O2, 2,2′-azino-bis (3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), and intercalated hemin [30,31]. A recent study utilized DNAzyme in a colorimetric LAMP assay for E. coli O157:H7 detection using a molecular beacon for a “signal- off” approach [32]. However, a challenge with non-specific amplification arose due to the beacon’s recognition as a primer [33,34].
Researchers have developed colorimetric LAMP assays for Salmonella, and Listeria monocytogens detection [35,36] by incorporation of Dz-00 DNAzyme sequence [37] in one of the inner primers, enabling color development in positive samples “signal- on” approach. However, the impact of incorporating other DNAzyme into LAMP assays remains unexplored. For example, EAD2 DNAzyme which has superior catalytic properties to all previously reported variants [38,39] has not yet been tested in DNAyzme-LAMP studies. In this study, we developed a novel colorimetric Dual DNAzyme reaction triggered by LAMP (cDDLAMP) assay for the detection of STEC strains targeting stx1, stx2, and eae genes by incorporating two different DNAzyme (EAD2, and Dz00) in both inner primers for LAMP reaction. The color signal analyzed using smartphone-based SpotXel reader and conventional microplate reader. Furthermore, our approach eliminates the need for culture-based enrichment, and complex DNA extraction by combining immunomagnetic concentration with a simple heat lysis of bacteria. A full depiction of our approach is presented in Fig 1A, which illustrates the enrichment of E. coli from milk and lettuce surface rinse water samples using streptavidin magnetic beads functionalized with anti-E. coli polyclonal antibodies (SMB-PAb). Following this enrichment step, genomic DNA (gDNA) of the enriched E. coli is extracted and amplified in heat block using the cDDLAMP method. This amplification generates dual DNAzyme-containing LAMP amplicons, which are then subjected to colorimetric detection. The new STEC detection method demonstrated a detection limit of 1–100 CFU/mL in pure culture, 100–103CFU/mL in spiked milk, and 104–109 CFU/25g of lettuce. Thus, the cDDLAMP method developed in this study has potential to be used for the monitoring of STEC outbreaks in resource-limited settings.
(A) Overall operation of the cDDLAMP assay for the detection of STEC strains. Culture free enrichment: E. coli was enriched from milk samples and lettuce surface rinse water using magnetic beads functionalized with anti-E. coli (α-E. coli) antibodies. cDDLAMP: gDNA was extracted and amplified by LAMP in heat block to produce DNAzyme-containing LAMP amplicons. Colorimetric detection: The colorimetric signal produced by DNAzyme reaction was captured for analysis by using SpotXel Reader app on a smartphone. A micro-USB-powered light pad and a light-proof enclosure were used to eliminate the impact of ambient light. (B) cDDLAMP: Top panel shows a schematic illustration of target stx1, stx2, and eae genes of E. coli O157:H7. LAMP Dumbbell: The forward inner primer (FIP) and backward inner primer (BIP) were modified with reverse-complement sequence of DNAzyme (rcDNAzyme), rcEAD2 or rcDz-00. LAMP product: LAMP reaction generates amplicons containing two types of DNAzymes (EAD2, and Dz-00) in each amplification unit. Upon adding hemin, the DNAzymes produce a colorimetric signal in the presence of H2O2 and TMB. The color change is captured by smartphone camera, and analyzed with SpotXel, a smartphone-based microplate reader application.
Materials and methods
Bacterial strains and genomic DNA extraction
STEC O157:H7 EDL932, a patient isolate from 1983 Michigan outbreak, was obtained from the American Type Culture Collection (ATCC 43894). Three clinical STEC strains (O111:H8, O26:H11, and O103:H11) were kindly provided by Dr. Pina Fratamico from USDA-APHIS (Beltsville, MD, USA), and were cultured at Department of Food Science, University of Tennessee (Knoxville, TN). Additionally, three other clinical STEC strains (O45:H2, O145:NT, and O121:H19) were obtained from STEC center at Michigan State University. Furthermore, three non-pathogenic reference E. coli strains (ATCC 43745, 25922, and K12), and four non-E. coli bacteria (Salmonella cholerasuis ATCC BAA 664, Salmonella typhimurium ATCC 14028, Pseudomonas aeruginosa, and Staphylococcus aureus) were provided by Department of Animal Science, University of Tennessee. Briefly, bacterial strains were cultured aerobically for 18 h at 37 °C in 5 mL of Tryptic Soy Broth (TSB, Becton Dickinson and Company, Franklin Lakes, NJ) in a shaking incubator at 225 rpm, and grown until the culture reaches confluency evaluated by the optical density (OD) at 600 nm. The OD was measured by using Ultrospec 10 (Biochrom, Cambourne, UK) and 1.0 OD at 600 nm was taken as 108 CFU/mL. The bacterial pellet was harvested by centrifugation at 14,000 rpm for 2 min, and DNA was extracted using the Wizard Genomic DNA Purification Kit (Promega, Madison, WI) following manufacturer’s instructions. The DNA yield was determined spectrophotometrically by using NanoDrop 2200c spectrophotometer (Thermo Fisher Scientific, Waltham, MA). Alternatively, bacterial DNA was extracted by heat treatment. In brief, bacterial pellet was harvested by centrifugation at 14,000 rpm for 2 min, resuspended in Ultrapure DNase/RNase-free distilled water (Invitrogen), and heated at 99°C for 15 min in a heat block (Thermo Fisher Scientific, Waltham, MA). The bacterial suspension was centrifuged at 16,000 rpm for 5 min to sediment cell debris leaving extracted DNA in the supernatant. The extracted DNA was used as the genomic DNA (gDNA) template for cDDLAMP assays.
LAMP primer modification, and optimization
Two Shiga-toxin-producing virulence genes (stx1and stx2) and intimin gene (eae gene) were selected as detection targets in this study. LAMP primers were adapted from previously published papers [23,40]. Another two primer sets targeting stx2 gene with different distance between the F3 and B3 (229 bp, and 214 bp) were adapted from previously published papers [23,41]. As shown in Fig 1B, LAMP primers target stx2, stx1, and eae gene sequences of E. coli O157:H7 EDL933 (accession: NC_002655, region: 1352816–1353015, 2996363–2996609, and 4667611–4667796, respectively). Oligonucleotide primers were obtained from Integrated DNA Technologies (IDT, Coralville, IA), and their sequences were shown in S1 Table. The forward inner primer (FIP) and backward inner primer (BIP) were modified with the target recognition site at 3′ end (F2 and B2), and target complementary site at 5′ end (F1c and B1c) were linked with reverse-complement sequence of DNAzyme (rcDNAzyme) (Fig 1B, and S1 Fig). Two different DNAzymes (EAD2, and Dz-00) [37,39] were used to modify FIP and BIP, respectively (Fig 1B, and S1 Fig). The normal primers without rcDNAzyme sequence served as control primer set (control primers) (S1 Fig).
The primer stocks (10×) used in this study were composed of 2 μM outer primers (F3 and B3), varying concentrations of loop primers (LB and LF, from 4 to 6 μM), and varying concentrations of inner primers (FIP, and BIP, from 8 to 16 μM). The optimized reaction mixture (10 μL) contained 5 μL of WarmStart LAMP 2× Master Mix (New England Biolabs), 1 μL of 10× primer stocks, 1 μL of gDNA template (at 1 ng/reaction=1.67 × 105 copies/reaction), and nuclease-free water (Thermo Fisher Scientific, Waltham, MA). To further improve assay performance, we modified the LAMP reaction by adding 0.8 M betaine (Thermo Fisher Scientific, Waltham, MA) and/or 320 U/mL Bst 3.0 DNA polymerase (New England Biolabs). The mixture was incubated at 65 °C in a heating block (Thermo Fisher Scientific, Waltham, MA) for 30–40 min. At the end of the amplification phase, the LAMP reaction was inactivated by heating the reaction mixture at 95 °C for 2 min. Reaction mixture without DNA extract (to account for amplicon carryover contamination) was included as a negative control (termed no templated control, NTC). Both the DNAzyme-LAMP products and normal LAMP products were verified using gel electrophoresis on a 1% agarose gel containing ethidium bromide. The electrophoresis was carried out at 80 V for 30 min, and the LAMP products were visualized under a UV transilluminator (UVP UVsolo Touch).
cDDLAMP procedure
The cDDLAMP procedure consisted of a LAMP reaction followed by formation of G-quadruplex DNAzymes within the LAMP products and reaction of their reaction with 3,3,5,5-tetramethylbenzidine (TMB) as shown in Fig 1B. A10 μL LAMP reaction mixture was heated at 95 ºC for 5 min, then cooled at room temperature, followed by the addition of 1.1 μL of hemin (200 μM in dimethyl sulfoxide [DMSO] MP Biomedicals). Temperature (25°C-95°C) and time (5 min-20 min) required for G-quadruplex DNAzyme folding in the LAMP amplicon were optimized. After the hemin incubation with LAMP amplicon, 50 μL of a TMB solution (TMB Substrate Kit, Thermo Fisher Scientific, Waltham, MA) was added to the LAMP reaction mixture and incubated at room temperature for 0–12 min. An Android smartphone was used to capture the image of reaction mixture in wells of a 96 well-plate, and the color intensity of each well was analyzed with SpotXel [42] or Model 680 plate reader at 655 nm (BioRad, Hercules, CA).
Evaluation of specificity and sensitivity of cDDLAMP
The specificity and sensitivity of LAMP targeting stx1, stx2 and eae genes were previously evaluated [23,40]. For verification of the specificity of our cDDLAMP system, E.coli O157:H7 EDL932 (ATCC 43894) was used as a positive control strain, while three non-pathogenic E.coli strains (ATCC 43745, 25922, and K12) and four non-E. coli bacteria (Salmonella cholerasuis ATCC BAA 664, Salmonella typhimurium ATCC 14028, Pseudomonas aeruginosa, and Staphylococcus aureus) were used as negative controls. Reaction mixture without target bacteria was used as another negative control and termed no-template control (NTC). Six clinical STEC strains O111:H8, O26:H11, O103:H11, O45:H2, O145:NT, and O121:H19 were also used for the evaluation of cDDLAMP system. cDDLAMP products were analyzed by agarose gel electrophoresis and by DNAzyme reaction as described above. To evaluate the sensitivity of cDDLAMP method, serial 10-fold dilutions of E. coli O157:H7 EDL932 (ATCC 43894) (1.67× 102−0 CFU/mL) were used to make bacterial lysates for crude DNA extraction as described above.
PCR amplification and sequencing
As a reference test, PCR amplification of stx1, stx2, and eae genes of STEC strains (O157:H7, O111:H8, O26:H11, O103:H11, O45:H2, O145:NT, and O121:H19) were carried out in C1000 thermal cycler (BioRad, CA). The PCR reaction mixture (25 μL) contained 1× PowerUp SYBER MasterMix (Applied Biosystems. Waltham, MA), F3 and B3 LAMP primers (0.4 μM each), and genomic DNA (10 ng). The PCR reaction was conducted with 1 min initial denaturation at 95°C followed by 35 cycles of denature (95°C, 15 sec), annealing (50°C, 30 sec) and extension (60°C, 1 min). The PCR products (247, 258, and 203 bp, respectively) were then confirmed by 1.5% agarose gel electrophoresis. PCR products were purified using the QIAquick PCR Purification Kit (Qiagen, Hilden, Germany) and sequenced at the University of Tennessee, Knoxville, Genomics Core Facility. Gene sequences were aligned and compared using Geneious software (Biomatters, Auckland, New Zealand).
Detection of E. coli O157:H7 in lettuce surface rinse water
Romaine lettuce was purchased from a retail store, immediately transported to the laboratory with proper storage conditions, and used for artificial inoculation by E. coli O157:H7 as previously described [43]. Before the inoculation, lettuce sample was cut into small pieces (approximately 4 cm2/piece), rinsed with deionized water, and irradiated with ultraviolet in a BSL-2 biosafety cabinet for 10 min on each side of the lettuce to eliminate the background microorganisms.
Approximately 1 g of the lettuce sample was placed into a Whirl-Pak homogenizer blender filter bag (Nasco, Fort Atkinson, WI), and 10 mL of the inoculum suspension was added in each bag. The inoculum contained approximately 5.2 ×105, 5.2 × 103, or 5.2 × 100 CFU/g as previously described [44,45]. Three lettuce samples tested to confirm absence of E. coli O157:H7 using Sorbitol MacConkey agar (SMAC) culturing methods and used as uninoculated controls [46]. The inoculated lettuce was placed into a sterile TSB (5 mL), and the lettuce surface rinse water was prepared by vigorous shaking at 115 rpm for 10 min. E. coli in the rinse water was enriched by using anti-E. coli antibody-coated magnetic beads. In brief, 50 μL of streptavidin magnetic beads (SMB, New England Biolabs, Ipswich, MA) were modified with 5 μL of biotinylated anti-E. coli polyclonal antibody (5 mg/mL with 0.1% sodium azide, Invitrogen) for 10 min at 37°C. The antibody-coated SMB (SMBs-PAb) was added to the lettuce surface rinse water and kept at 37 °C for another 30 min without shaking. The SMBs-PAb-E. coli complexes were collected for 1 min on a magnetic bead separation rack (Thermo Fisher Scientific, Waltham, MA). Then, the SMB pellet was washed twice with 500 μL of PBST (1x PBS with 0.05% Tween 20, pH 7.2) and resuspended in 100 μL of PBST. For downstream cDDLAMP assay, genomic DNA (gDNA) was extracted from each dilution via heat lysis as described above.
For detection of E. coli O157:H7 on large volume of lettuce, aliquots of 1.5 ml of the inoculum suspension were applied across abroad range of concentrations (103-9 CFU) on 25 g of lettuce, approximately equivalent to 10¹–107 CFU/g). Within this range, 10³–104 CFU/25 g (approximately 10¹–102 CFU/g) is categorized as a “low-level inoculation”. The inoculum was equally divided in small volumes and inoculated at 5 to 10 locations on the lettuce sample to facilitate drying as described previously [24,47,48]. Three lettuce samples tested to confirm absence of E. coli O157:H7 using SMAC culturing methods and used as uninoculated controls [46]. The inoculated lettuce was transferred to filter Whirl Pak bags (1.6 mL) as described previously [49–51], and lettuce surface rinse water was prepared by addition of 225 ml of buffered peptone water (BD Diagnostic Systems, Sparks, MD) followed by shaking at room temperature at 185 rpm. Aliquots (1 mL) of each sample were centrifuged at 16,000 rpm for 3 min, and pellets were suspended in 100 µL of Ultrapure DNase/RNase-free Distilled Water (Invitrogen). Genomic DNA was extracted from the bacterial pellet by heat lysis as described above. Another aliquot (5 mL) of each sample was used for enrichment of E. coli with SMBs-PAb as described above for genomic DNA extraction via heat lysis.
Detection of E. coli O157:H7 in milk samples
Aliquots (5 mL each) of commercial pasteurized bovine whole milk were artificially spiked with bacteria at different cell densities: 5.2 × 105, 5.2 × 103, and 5.2 × 100 CFU/mL [52]. The spiked milk samples were diluted with 5 mL of PBST at 1:1 ratio. E. coli in the spiked sample was enriched by using SMBs-PAb and used for gDNA extraction.
Statistical analysis
A two-way ANOVAs was performed to determine if there were a significant difference in the signal to noise ratio (S/N) of the cDDLAMP of all target genes (stx1, stx2, and eae genes), and a one-way ANOVA was performed to make a single comparison of 3 different primer sets targeting stx2 gene. All post hoc tests used Tukey’s honestly significant difference (HSD) method. Data represents mean values from three independent experiments, and with error bars indicating standard deviations. A p-value <0.05 was considered significant. The cut-off value represented the upper bound of 95% confidence interval for negative samples (mean + 2SD) [53]. The correlation analyses and visualization were done using JMP Pro, Version 17. OS (64-bit) to provide an estimate for the association among the SpotXel and microplate reader. All analyses were conducted using JMP Pro, Version 17. OS (64-bit). All graphs were prepared using the GraphPad Prism software (Version 8, GraphPad Software Inc.).
Result
Optimization of reaction conditions, and validation of cDDLAMP system
The LAMP reaction conditions were optimized by testing different concentrations of primers, different amplification times, and by adding 0.8 M betaine and 320 U/mL Bst polymerase 3.0 to the reaction mixture. The reaction temperature of DNAzyme was also optimized.
While optimizing the concentration of primers to improve assay performance, we found that increasing concentrations of loop primers (from 0.4 to 0.6 µM) and inner primers (from 0.8 to 1.6 µM) improved the amplification time from 40 min to 30 min while increasing the S/N of all target genes (p=0.0004) (Fig 2A, S2A Fig). Next, we modified the LAMP mixture by supplementing the Warmstart master mix with betaine (0.8 M) and/or Bst polymerase 3.0 (320 U/ml) and assessed the improvements in amplification efficiency. A progressive increase of the S/N was observed with all target genes, stx1, stx2, and eae (p<0.0001), with the addition of Bst polymerase and betaine. The addition of betaine alone to the reaction mixture led to a noticeable increase in the S/N of all target genes, stx1, stx2, and eae (p=0.0008, 0.0005, and 0.0003, respectively). On the other hand, Bst polymerase addition alone did not significantly change the S/N of all target genes, stx1, stx2, and eae (p=0.989, 0.934, and 0.765 respectively) (Fig 2B, S2B Fig).
Heat map showing the impact of primer concentration, master mix, and temperature modifications on the signal to noise ratio (S/N), and detection time. The modifications, applied progressively from top to bottom, showed improvements in S/N and reduced detection time. All reactions were evaluated by colorimetric measurement, and data from three independent experiments are shown with error bars representing standard error of the means. (A) Increased primer concentrations. Shown are identical reactions differing only in the concentration of inner primers (FIP/BIP, 0.8-1.6 µM), and loop primers (LF/LB, 0.4-0.6 µM). The value on the right x-axis signifies the amplification time (30 and 40 min). a–d; Means carrying different superscripts are significantly different at p < 0.05 (***P=0.0004). (B) Supplementation of NEB WarmStart reaction mix with betaine (0.8 M) and/or Bst3.0 polymerase 3 (320 U/ml) compared with normal NEB WarmStart” reaction mix. a–g; Means carrying different superscripts are significantly different at p < 0.05 (***P < 0.0008, ****P < 0.0001, and ns p > 0.05). (C) The effect of reaction temperature (95°C or room temperature [RT]) upon hemin interaction with active DNAzymes (EAD2 and Dz-00). The value on the right x-axis signifies the detection time (1 and 30 min). a–c; Means carrying different superscripts are significantly different at p < 0.05 (****p < 0.0001).
Increasing the temperature for DNAzyme-hemin complex formation from 25ºC to 95ºC improved the S/N of all target genes, stx1, stx2, and eae (p<0.0001), while shortening the detection time from 30 min to 1 min (Fig 2C, S2C Fig).
Different primer sets targeting stx2 gene were tested for the cDDLAMP assay. Among these, the primer set with a 258 bp distance between F3 and B3 demonstrated a significantly higher S/N (p < 0.0001) compared to the other two primer sets (p > 0.05) (S3 Fig). Consequently, the primer set with the 258 bp distance between F3 and B3 was selected for use in subsequent experiments.
Feasibility of cDDLAMP
Shiga toxin genes (stx1, stx2, and eae) of E. coli O157:H7 were detected with the optimized cDDLAMP to verify the feasibility of the assay. The S/N of the cDDLAMP reaction with rcDNAzyme primers exhibited a significantly higher colorimetric signal for all target genes, stx1,stx2, and eae (p<0.0001), compared to the LAMP reaction containing normal primers without rcDNAzymes (Fig 3A). As seen in the image of the 96-well plate (Fig 3B), the amplification of E. coli O157:H7 genes by cDDLAMP reactions resulted in a clearly visible dark blue color change in the presence of target genes, indicating the feasibility of naked-eye detection. Furthermore, an increase in cDDLAMP amplicon size due to the incorporation of two different DNAzyme sequences (EAD2 & Dz-00) was clearly observed when visualized using agarose gel electrophoresis (Fig 3C). As shown in Fig 3D, the SpotXel reader and microplate reader readouts positively correlated (R = 0.9463) with a significant correlation probability (P<.0001), and an excellent linear relationship .
(A) Signal to noise ratio (S/N) of the cDDLAMP targeting stx1, stx2, and eae genes compared with LAMP normal primers. Means from three independent experiments are shown with error bars representing standard error of the means. a–b; Asterisks above means denote significant differences and means carrying different superscripts are significantly different at p < 0.05 (****P < 0.0001). (B) A representative image of color development in a 96-well plate. (C) Gel electrophoresis image of typical cDDLAMP amplicons using rcDNAzyme primers (rcP) compared with LAMP amplicons with normal primers (NP). Scatter plot showing the correlation coefficient and probability (R = 0.9463, p <.0001) between data obtained by SpotXel (x-axis) and microplate reader (y-axis, OD: optical density at 655 nm). (D) The shaded zone represents the 95% confidence interval of the trendline.
Evaluation of cDDLAMP`s specificity, and sensitivity for STEC detection
For the specificity evaluation of cDDLAMP system, gDNA of O157:H7 EDL932 (ATCC 43894), six clinical STEC strains (O111:H8, O26:H11, O103:H11, O45:H2, O145:NT, and O121:H19), three non-pathogenic E. coli strains (ATCC 43745, 25922,and K12), and four non-E. coli bacteria (Salmonella cholerasuis ATCC BAA 664, Salmonella typhimurium ATCC 14028, Pseudomonas aeruginosa, and Staphylococcus aureus) were tested. No cross reaction with the non-pathogenic E. coli strains nor non-E. coli bacteria were observed with the S/N less than the cut-off value, whereas all STEC strains displayed a significant higher S/N for their harboring toxin gene(s) than the cut-off value (p<0.0001) (Fig 4). A representative image of the color signal are indicated (S4, and S5A Figs). These data were confirmed by agar gel electrophoresis (S4, and S5B Figs).
The following bacterial species were tested: O157:H7 EDL932 (ATCC 43894), six clinical STEC strains (O111:H8, O26:H11, O103:H11, O45:H2, O145:NT, and O121:H19), three non-pathogenic E. coli strains(ATCC 43745, 25922,and K12), and four non-E. coli bacteria (Salmonella cholerasuis ATCC BAA 664, Salmonella typhimurium ATCC 14028, Pseudomonas aeruginosa, and Staphylococcus aureus). Means from three independent experiments are shown with error bars representing standard error of the means. a–c; Asterisks above means denote significant differences and means carrying different superscripts are significantly different at p < 0.05 (****P < 0.0001). The cut-off value of stx1 indicated as dotted line = 1.45. The stx2 and eae genes were 1.37and 1.18, respectively.
To verify the sensitivity of the cDDLAMP method, DNA extracted from serial 10-fold dilutions of O157:H7 EDL932 (ATCC 43894) (1.67×102−0 CFU/ml) were used as templates. The stx1 and eae DDLAMP assays consistently detected down to 1.67 × 100 CFU/mL. However, stx2 cDDLAMP was 100-fold less sensitive. Tentative LODs of cDDLAMP for stx1, stx2, and eae genes were found to be 1.67 × 100 CFU/mL, 1.67× 102 CFU/mL, and 1.67× 100 CFU/mL, respectively (Fig 5).
The serial 10-fold dilutions of O157:H7 EDL932 (ATCC 43894) (1.67 × 100-2 CFU/mL) were used in this experiment. The values represent the average from three independent experiments, and the individual data points are shown. OD: optical density at 655 nm.
PCR detection and sequence analysis
The toxin genes in O157:H7, O111:H8, O26:H11, O103:H11, O45:H2, O145:NT, and O121:H19 were confirmed to be stx1+/stx2+/eae+, stx1+/stx2+/eae-, stx1+/stx2-/eae-, stx1+/stx2-/eae+, stx1+/stx2-/eae+, stx1-/stx2+/eae+, and stx1-/stx2+/eae+ respectively (S5C, and S6 Figs).
DNA sequencing validated the specificity of cDDLAMP by confirming the identity of the amplified fragments and ensuring they correspond to the target toxin genes (stx1, stx2, or eae) without evidence of nonspecific amplification. Sequence alignments displayed homologies indicated by shading: black (100%), dark gray (80–100%), light gray (60–80%), and white (<60%), in comparison to the reference sequence of E. coli O157:H7 (strain EDL933*; accession number CP008957.1), as illustrated in Fig 6.
ClustalW alignment of the stx1 (A), stx2 (B), and eae (C) genes from STEC strains is presented. Target sequences for stx1, stx2, and eae from E. coli O157:H7 (strain EDL933*) were retrieved from the GenBank database (accession number CP008957.1). Annotation labels indicate the binding regions for the primers, including outer primers (F3, B3), loop primers (LF, LB), forward inner primer (FIP; F1c, F2), and backward inner primer (BIP; B1c, B2). Shading indicates sequence similarity as follows: black (100%), dark gray (80–100%), light gray (60–80%), and white (<60%). Sequence logos, generated using Geneious 2019.2.1 software, display the consensus across the sequences.
Rapid detection of E. coli O157:H7 in spiked lettuce by cDDLAMP
E. coli (5.2 ×100-5 CFU/g) in lettuce surface rinse water was recovered by SMB-PAb enrichment. gDNA was extracted from E. coli and amplified using cDDLAMP. The resulting amplicons were analyzed through colorimetric detection. All target genes (stx1, stx2, and eae) were detected by cDDLAMP down to 5.2×103 CFU/g lettuce (p<0.0001) (Fig 7). For the uninoculated controls, all target genes were tested negative by cDDLAMP, confirming the absence of false positive reactions. Notably, the stx1 cDDLAMP consistently detected E. coli O157:H7 at an even lower concentration (5.2 ×100 CFU/g) with all three replicates above the cut-off value, 1.18. On the other hand, stx2 cDDLAMP was less sensitive, with all three replicates of the lower concentration (5.2×100 CFU/g) under the cut off value of 0.957. For eae gene, cDDLAMP could detect one out of three replicates (above the cut off value of 1.06) at 5.2×100 CFU/g.
gDNA was extracted from recovered E. coli, amplified with cDDLAMP, and analyzed colorimetrically (A). Results represent means from three independent experiments, with error bars representing standard error. Significant differences (p < 0.05) are denoted by asterisks (****P < 0.0001) and different superscripts (a–d). The cut off value of stx1 indicated as dotted line = 1.18. The stx2 and eae genes were 0.96 and 1.06, respectively. A photograph of representative plates is shown in (B). NTC: no template control; PC: positive control.
Furthermore, the sensitivity of cDDLAMP was evaluated by using a large volume of lettuce that had been spiked with low- level inoculation down to103 CFU/25g (Fig 8A and S7A Fig). In this experiment, enrichment with SMBs-PAb was not included. For the uninoculated controls, all target genes (stx1, stx2, and eae) were tested negative by cDDLAMP. The stx1 cDDLAMP consistently detected E. coli O157:H7 down to 105 CFU/25g lettuce with all three replicates above the cut off value of 1.44. In comparison, eae cDDLAMP could be detected in two out of three replicates (above the cut off value of 1.44) down to approximately 105 CFU/25g. Notably, the cDDLAMP assay of all target genes failed to detect the E. coli O157:H7 at 103-4 CFU/25g lettuce (p>0.05). It is also worth mentioning that stx2 cDDLAMP failed to detect E. coli O157:H7 in large volume of spiked lettuce.
gDNA of the recovered E. coli without SMB-PAb enrichment (A) or with SMB-PAb enrichment (B) was amplified with cDDLAMP. In (A), the cut off value of stx1, and eae genes indicated as dotted line = 1.44. In (B), the cut off value of stx1/2 and eae genes (dotted line) were 2.08 and 1.12, respectively. Means from three independent experiments are shown with error bars representing standard error. Significant differences (p < 0.05) denoted by different superscripts (a–h). n.s.: Not significant (ns p > 0.05).
To improve the sensitivity, immunomagnetic separation (IMS) using SMBs-PAb was conducted prior to cDDLAMP reaction. As shown in Fig 8B, 104 CFU/25g of O157:H7 could be detected by stx1 and eae cDDLAMP with all three replicates above the cut off value of 2.08, and 1.12, respectively. Stx2 cDDLAMP could detect 109 CFU/25 g of O157:H7 (Fig 8B) which could not be detected without IMS (Fig 8A). Photographic images of this assay were shown in S7B Fig.
cDDLAMP detection of E. coli O157:H7 in spiked raw milk sample
cDDLAMP was evaluated for the detection of E. coli O157:H7 in raw milk by spiking the samples with 5.2×100-5 CFU/mL. E. coli was enriched from milk samples by using SMB-PAb (Fig 9). For the uninoculated controls, all target genes (stx1, stx2, and eae) were tested negative by cDDLAMP. Milk samples containing O157:H7 at the cell density of 5.2×103 or 5.2×105 CFU/mL consistently produced a significant signal for all target genes (stx1, stx2, and eae) (p < 0.0001) with all three replicates above the cut off value of 1.29, 1.05, and 1.10, respectively. The LOD of stx1 and eae cDDLAMP could reach 5.2×100 CFU/mL, but there was a high variation of the signals.
gDNA of E. coli was extracted and amplified with cDDLAMP. The cDDLAMP amplicons were reacted with TMB, and the signal to noise ratio (S/N) was calculated (A). A representative photograph of well plate is shown in (B). Means from three independent experiments are shown with error bars representing standard error. Significant differences (p < 0.05) are denoted by asterisks (****P < 0.0001) and different superscripts (a–d). The cut off value of stx1 indicated as dotted line = 1.29. The stx2 and eae genes were 1.05 and 1.10, respectively.
Use of smartphone app, SpotXel, in cDDLAMP assay
Use of a smartphone app for analysis of color change will allow users to conduct cDDLAMP assay without the need of a relatively bulky and expensive microplate reader. In the following experiments, a smartphone app, SpotXel, was evaluated as an alternative method for the microplate reader which was used in the experiments above. Photographic images of experiments shown in Figs 7–9 were analyzed by using SpotXel and plotted against OD values obtained by a microplate reader.
Based on the data obtained by cDDLAMP assay for the detection of stx1, stx2, and eae genes of O157:H7 in food matrices, it was found that the optical density data obtained by SpotXel and microplate reader had a positive correlation with a correlation coefficient (R) of 0.8675, and the linear equation derived from this relationship was (Fig 10, S2A Table). Similarly, based on the data obtained by cDDLAMP testing of spiked lettuce samples with and without IMS, the correlation coefficient (R) and the linear equation derived from this relationship were 0.8605 and
respectively (Fig 11, S2B Table).
The food matrices (milk and lettuce) artificially inoculated with E. coli O157:H7 at 5.2 x 105,3,0 CFU/mL or g. Red and blue data points represent SpotXel reader and microplate reader (OD 655 nm), respectively. Each dot indicates a single data point. The data for the plots are appended in S2A Table.
Lettuce was artificially inoculated with E. coli O157:H7109-3CFU/25g. E. coli were recovered from the lettuce with IMS (IMS) or without IMS (No IMS). Recovered E. coli was subjected to cDDLAMP. Red and blue data points represent SpotXel reader and microplate reader (OD 655 nm), respectively. Each dot indicates a single data point. The data for the plots are appended in S2B Table.
Discussion
Point-of-Care (POC) methods with high specificity and sensitivity are crucial for monitoring food sources for STEC [54]. Among food commodities, raw milk is associated with isolated cases and extensive global foodborne outbreaks linked to STEC [55–57]. STEC causes approximately 30% of produce-related disease outbreaks, ranking second only to norovirus [58–62]. This public health concern is largely due to the consumption of raw produce with insufficient cleaning [63,64]. Detecting STEC contamination in lettuce is critical because eight foodborne outbreaks have been reported in the United States [65], and 26 cases were confirmed in the United States in 2010 [66].
Several studies highlight the challenges in STEC detection in milk and leafy vegetables due to the presence of inhibitory compounds (such as chlorophylls and polysaccharides) [67–69], very low levels of STEC contamination, and interfering background microbiota [70,71]. The challenge of isolating the target pathogen increases due to the existence of microbiota that interferes with culture-based STEC detection [72,73]. This issue is worsened especially when the enrichment period is extended to 12 or 24-hours for milk and lettuce, respectively, as recommended in the FDA BAM protocol [74,75]. Thus, the implementation of immunomagnetic separation (IMS) would be an effective tool for enhancing the STEC recovery from complex food matrices that contain high background microbiota [76–79].
Simultaneous detection of common virulence genes (stx1, stx2, and eae) is important due to the growing clinical importance of non-O157 STEC strains worldwide [4] beside the most relevant STEC serotypes, E. coli O157:H7 [80]. STEC genomes contain at least one Shiga-toxin (Stx) encoding genes (stx1 or stx2) [81]. DNAzyme-modified inner primers can be tailored to detect various target genes without compromising assay specificity [82]. In this study, we validated the novel cDDLAMP approach by employing a previously established LAMP primer set, which has been verified for its specificity and sensitivity in detecting stx1, stx2, and eae genes [23,40]. Our results showed that the stx1 and/or stx2 genes could be successfully detected by cDDLAMP assay in all tested STEC strains without false positive reaction with non-STEC E. coli strains or non-E. coli bacteria. The eae gene has been reported to cause human illness [83]. The presence of eae gene in E. coli O157:H7 and O103:H11 was reported in previous studies using LAMP assays [23,40] and confirmed in this study using cDDLAMP method. However, our assay did not detect the eae gene in O26:H11 and O111:H8 strains, despite these serotypes typically being associated with specific eae subtypes (e.g., β1 and θ) [84–86]. This may indicate that not all strains within these serotypes consistently harbor the eae gene, as eae-negative strains of the O111 serotype have been reported in previous studies [23,87]. Alternatively, the primers used in this study, designed based on previous study to target the eae-γ1 subtype associated with the O157:H7 serotype [23], may have limited the detection of other eae subtypes such as β1 or θ.
ABTS substrate has been used in previous DNAzyme-LAMP studies [35,36]. In our study with cDDLAMP assay, TMB was used as DNAzyme substrate as the substrate was shown to have a higher sensitivity and faster reaction rate compared to ABTS [88]. The LOD of our cDDLAMP assay in pure culture was estimated to be 1–100 CFU/mL which is comparable to that of other STEC LAMP assays reported in previous studies [23,24,41,89–94]. This sensitivity of cDDLAMP assay is enough for practical applications such as detection of STEC in vegetable rinse water, as the infectious dose of E. coli O157:H7 for humans is reported to be101–102 CFU/mL [7,11].
cDDLAMP achieves sensitivity comparable previously reported LOD of 4.1 x104 CFU/ml for E. coli O157 in raw milk using LAMP [91], and 2.26×100 CFU/mL E. coli O157:H7 using RT-LAMP and visual LAMP [94]. However, our assay has the advantage of a 30-minute enrichment instead of a ≥3-hour culture enrichment [91]. Additionally, this method can detect low levels of STEC (100 CFU/g targeting stx1 and 103 CFU/g targeting stx2 and eae in spiked lettuce with a LOD lower than that previously reported [23].
In comparison to commercial diagnostic kits, such as the Loopamp Escherichia coli O157 Detection Kit and Thermo Scientific™ SureTect™ Escherichia coli O157:H7 and STEC Screening PCR Assay, which offer valuable detection capabilities, there are certain limitations. These include longer enrichment times (8–24 hours) and the need for specialized equipment (Loopamp Realtime Turbidimeter or Real-Time PCR instruments), which may not be readily available in resource-limited settings. Furthermore, the Loopamp kit’s sensitivity is limited to detecting 60 CFU/test, reducing its effectiveness for detecting low bacterial concentrations. In contrast, our method utilizes a 30-minute enrichment with streptavidin magnetic beads (SMB-PAb), followed by rapid results within 30 minutes after loading the gDNA sample into a heating block, which is much faster than the 60–80 minutes required by the commercial kits. Additionally, the use of a smartphone-based microplate reader (SpotXel) makes our assay cost-effective and accessible, even in settings with limited resources. Thus, our approach offers a quicker, more accessible, and potentially more sensitive alternative for STEC detection compared to current commercial diagnostic kits.
Currently, the food production system requires testing samples to be collected in larger volumes with low bacterial concentrations to avoid expensive homogenate preparation [24]. Therefore, we inoculated the surface of intact lettuce (25 g) with 103-9 CFU in our study. We were able to detect the presence of 105 and 106 CFU/25 g without enrichment for stx1, and eae genes, respectively, similar to previous studies [24,48]. However, IMS significantly improved the LOD by ten to one hundred-fold for stx1 and eae genes, respectively (104 CFU/25g). Furthermore, a strong and significant correlation of the color signal detection between smartphone-based SpotXel reader and the microplate reader with the accurate clustering of the positive and negative signal readout by each reader, indicating great promise for transforming POC diagnostics, offering a convenient, rapid, and accessible solution for the signal readout and analysis as previously reported DNAzyme-LAMP for SARS-CoV-2 detection [95]. The inconsistency between replicates in our study at extremely low cell counts could be due to negative or poor amplification efficiency of LAMP associated with low template copy numbers [96,97], resulting in increased standard deviation when compared to higher copy numbers [98,99].
Despite the ultra-sensitive detection of stx1 and eae STEC genes with cDDLAMP, neither magnetic bead enrichment (109 CFU/25g), nor culturing (up to 100-fold; 100 CFU/mL) resulted in the same sensitivity with stx2 gene detection. Studies evaluating STEC detection have shown influence on the accuracy and sensitivity of the stx target gene due to several factors: (i) potential mismatches of LAMP primer sequences between the strain and stx2 gene used for primer design [23,48], (ii) the presence of bacteriophage [100], (iii) DNA purity [65,101], and loss of stx-coding phage after sub-cultivation [100,102–104] with stx2 loss more commonly reported [102,104,105]. Moreover, a study found stx instability in STEC O157: H7 isolates(n=14), and confirmed stx loss through whole genome sequencing and PCR results [106].
The cDDLAMP assay is a cost-effective method for detecting STEC strains without expensive machines or extraction methods, making it suitable for resource-limited locations. It incorporates two types of DNAzymes and improves sensitivity with magnetic bead enrichment. Future research should incorporate a diverse range of STEC clinical isolates with varying eae, and stx2 subtypes to validate the assay’s effectiveness for broad-spectrum STEC detection in food samples. Additionally, such studies would contribute to a deeper understanding of the genetic heterogeneity and subtype variability of eae among non-O157 STEC strains.
Supporting information
S1 Fig. cDDLAMP assay obtained by rcDNAzyme modifications in all three primer set candidates targeting stx1, stx2, and eae genes.
Positions of rcDNAzyme (EAD2, and DZ-00) in the sequences of FIP/BIP compared with normal primers (LAMP assay).
https://doi.org/10.1371/journal.pone.0320393.s001
(TIF)
S2 Fig. Photograph of the corresponding well plate reflecting the progressive improvement of the cDDLAMP reaction condition based on the optimization ofprimer concentration (A), master mix (B), and temperature (C).
The photo demonstrates the corresponding changes in absorption based on reaction optimization.
https://doi.org/10.1371/journal.pone.0320393.s002
(TIF)
S3 Fig. Evaluation of cDDLAMP using 3different primer sets targeting stx2 gene of E. coli O157:H7 with varying distance between the outer primers (F3/B3): 258 bp, 229 bp, and 214 bp.
All reactions were evaluated by colorimetric change with a representative photograph of well plate shown. Means from three independent experiments are shown with error bars representing standard error of the means (****P < 0.0001, and ns p > 0.05).
https://doi.org/10.1371/journal.pone.0320393.s003
(TIF)
S4 Fig. Photograph of the corresponding well plate reflecting the specificity of cDDLAMP of all target genes (stx1, stx2, and eae genes) colorimetrically and by gel electrophoresis detection of the active dual DNAzyme LAMP amplicons.
The tested STEC strains are designated as E. coli O157:H7, O111:H8, O26:H11, and O103:H11.
https://doi.org/10.1371/journal.pone.0320393.s004
(TIF)
S5 Fig. Photograph of the corresponding well plate reflecting the color signal of cDDLAMP of all target genes (stx1, stx2, and eae genes).
(A). Gel electrophoresis detection of the active dual DNAzyme LAMP amplicons (B). Gel electrophoresis of the PCR amplicons of all target genes (stx1, stx2, and eae genes) (C). Tested STEC strains are labeled as O157:H7, O45:H2, O145:NT, and O121:H19.
https://doi.org/10.1371/journal.pone.0320393.s005
(TIF)
S6 Fig. Gel electrophoresis of the PCR amplicons 247 bp, 258 bp, and 203 bp of stx1, stx2, and eae genes, respectively.
The tested STEC strains are designated as E. coli O157:H7, O111:H8, O26:H11, and O103:H11.
https://doi.org/10.1371/journal.pone.0320393.s006
(TIF)
S7 Fig. Photograph of the corresponding well plate reflecting cDDLAMP detection of artificially inoculated lettuce by E. coli O157:H7 (103-9 CFU/25g) without SMB-PAb enrichment (A) or with SMB-PAb enrichment (B).
https://doi.org/10.1371/journal.pone.0320393.s007
(TIF)
S1 Table. Oligonucleotide primers used in the cDDLAMP assay. rcDNAzyme sequence (Dz-00 in BIP, and EAD2 in FIP) is underlined.
https://doi.org/10.1371/journal.pone.0320393.s008
(DOCX)
S2 Table. Colorimetric signal to noise ratio results of SpotXel reader and microplate reader (OD655nm) with A). E. coli O157:H7 spiked concentration 5.2 × 105,3,0 CFU/ g or mL of food matrices (#1–72) and B) E. coli O157:H7 spiked concentration 109-3 CFU/25g with or without SMB-PAb enrichment (#1–144).
https://doi.org/10.1371/journal.pone.0320393.s009
(DOCX)
References
- 1. Control CfD, Prevention. Surveillance for foodborne disease outbreaks—United States, 2009–2010. MMWR Morbid Mortal Weekly Rep. 2013;62(3):41–7.
- 2. Gould L, Walsh K, Vieira A, Herman K, Williams I, Hall A, et al. Surveillance for foodborne disease outbreaks—United States, 1998–2008. Morbid Mortal Week Rep: Surveill Summar. 2013;62(2):1–34.
- 3. Rangel J, Sparling P, Crowe C, Griffin P, Swerdlow D. Epidemiology of Escherichia coli O157:H7 outbreaks, united states, 1982–2002. Emerg Infect Dis. 2005;11(4):603.
- 4. Scallan E, Hoekstra RM, Angulo FJ, Tauxe RV, Widdowson M-A, Roy SL, et al. Foodborne illness acquired in the United States—major pathogens. Emerg Infect Dis. 2011;17(1):7–15. pmid:21192848
- 5. Parsons BD, Zelyas N, Berenger BM, Chui L. Detection, characterization, and typing of shiga toxin-producing Escherichia coli. Front Microbiol. 2016;7:478. pmid:27148176
- 6.
Organization WH. Diarrhoeal Disease. https://wwwwhoint/news-room/fact-sheets/detail/diarrhoeal-disease. 2017.
- 7.
Agriculture USDo. Draft Risk Profile for Pathogenic Non-O157 Shiga Toxin-Producing Escherichia coli. U.S. Department of Agriculture, Washington, DC. 2011.
- 8. Hara-Kudo Y, Konishi N, Ohtsuka K, Iwabuchi K, Kikuchi R, Isobe J, et al. An interlaboratory study on efficient detection of Shiga toxin-producing Escherichia coli O26, O103, O111, O121, O145, and O157 in food using real-time PCR assay and chromogenic agar. Int J Food Microbiol. 2016;230:81–8. pmid:27153219
- 9. Lefterova MI, Slater KA, Budvytiene I, Dadone PA, Banaei N. A sensitive multiplex, real-time PCR assay for prospective detection of Shiga toxin-producing Escherichia coli from stool samples reveals similar incidences but variable severities of non-O157 and O157 infections in northern California. J Clin Microbiol. 2013;51(9):3000–5. pmid:23843484
- 10. Service USDoAFSaI. E. coli 0157:H7 Contamination of Beef Products, vol. 76. FR 182. 2011.
- 11. Teunis PFM, Ogden ID, Strachan NJC. Hierarchical dose response of E. coli O157:H7 from human outbreaks incorporating heterogeneity in exposure. Epidemiol Infect. 2008;136(6):761–70. pmid:17672927
- 12. Gould LH, Bopp C, Strockbine N, Atkinson R, Baselski V, Body B, et al. Recommendations for diagnosis of shiga toxin-producing Escherichia coli infections by clinical laboratories. MMWR Recomm Rep. 2009;58(RR-12):1–14. pmid:19834454
- 13. Jenkins C, Perry NT, Godbole G, Gharbia S. Evaluation of chromogenic selective agar (CHROMagar STEC) for the direct detection of Shiga toxin-producing Escherichia coli from faecal specimens. J Med Microbiol. 2020;69(3):487–91. pmid:31935188
- 14. Fratamico PM, DebRoy C, Liu Y, Needleman DS, Baranzoni GM, Feng P. Advances in molecular serotyping and subtyping of Escherichia coli. Front Microbiol. 2016;7:644. pmid:27199968
- 15. Rani A, Donovan N, Mantri N. Review: The future of plant pathogen diagnostics in a nursery production system. Biosens Bioelectron. 2019;145:111631. pmid:31574353
- 16. Mori Y, Notomi T. Loop-mediated isothermal amplification (LAMP): a rapid, accurate, and cost-effective diagnostic method for infectious diseases. J Infect Chemother. 2009;15(2):62–9. pmid:19396514
- 17. Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N, et al. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 2000;28(12):E63. pmid:10871386
- 18. Francois P, Tangomo M, Hibbs J, Bonetti E-J, Boehme CC, Notomi T, et al. Robustness of a loop-mediated isothermal amplification reaction for diagnostic applications. FEMS Immunol Med Microbiol. 2011;62(1):41–8. pmid:21276085
- 19. Kaneko H, Kawana T, Fukushima E, Suzutani T. Tolerance of loop-mediated isothermal amplification to a culture medium and biological substances. J Biochem Biophys Methods. 2007;70(3):499–501. pmid:17011631
- 20. Kanki M, Seto K, Harada T, Yonogi S, Kumeda Y. Comparison of four enrichment broths for the detection of non-O157 Shiga-toxin-producing Escherichia coli O91, O103, O111, O119, O121, O145 and O165 from pure culture and food samples. Lett Appl Microbiol. 2011;53(2):167–73. pmid:21585404
- 21. Ohtsuka K, Tanaka M, Ohtsuka T, Takatori K, Hara-Kudo Y. Comparison of detection methods for Escherichia coli O157 in beef livers and carcasses. Foodborne Pathog Dis. 2010;7(12):1563–7. pmid:20704509
- 22. Stratakos AC, Linton M, Millington S, Grant IR. A loop-mediated isothermal amplification method for rapid direct detection and differentiation of nonpathogenic and verocytotoxigenic Escherichia coli in beef and bovine faeces. J Appl Microbiol. 2017;122(3):817–28. pmid:27992094
- 23. Wang F, Jiang L, Ge B. Loop-mediated isothermal amplification assays for detecting shiga toxin-producing Escherichia coli in ground beef and human stools. J Clin Microbiol. 2012;50(1):91–7. pmid:22031701
- 24. Wang F, Jiang L, Yang Q, Prinyawiwatkul W, Ge B. Rapid and specific detection of Escherichia coli serogroups O26, O45, O103, O111, O121, O145, and O157 in ground beef, beef trim, and produce by loop-mediated isothermal amplification. Appl Environ Microbiol. 2012;78(8):2727–36. pmid:22327594
- 25. Chen F, Wang J, Li W, Zhang Y, Xiu L, Hu Q, et al. Visual and rapid detection of Escherichia coli O157: H7 in stool samples by FTA card-based loop-mediated isothermal amplification. Zoonoses. 2023;3(1).
- 26. Tanner NA, Zhang Y, Evans TC Jr. Visual detection of isothermal nucleic acid amplification using pH-sensitive dyes. Biotechniques. 2015;58(2):59–68. pmid:25652028
- 27. Nawattanapaibool N, Saiyudthong S, Changsen C, Buates S. Rapid and simple detection of shiga toxin-producing Escherichia coli (Stec) o157: H7 and stec NON-O157: H7 serotypes using colorimetric loop-mediated isothermal amplification assay. Southeast Asian J Trop Med Publ Health. 2021;52(2):240–58.
- 28. Uribe-Alvarez C, Lam Q, Baldwin DA, Chernoff J. Low saliva pH can yield false positives results in simple RT-LAMP-based SARS-CoV-2 diagnostic tests. PLoS One. 2021;16(5):e0250202. pmid:33951060
- 29. Wang S, Cai G, Duan H, Qi W, Lin J. Automatic and multi-channel detection of bacteria on a slidable centrifugal disc based on FTA card nucleic acid extraction and recombinase aided amplification. Lab Chip. 2021;22(1):80–9. pmid:34796896
- 30. Kosman J, Juskowiak B. Peroxidase-mimicking DNAzymes for biosensing applications: a review. Anal Chim Acta. 2011;707(1–2):7–17. pmid:22027115
- 31. Roembke BT, Nakayama S, Sintim HO. Nucleic acid detection using G-quadruplex amplification methodologies. Methods. 2013;64(3):185–98. pmid:24135042
- 32. Lee J-E, Toushik SH, Park H-J, Kim S-A, Shim W-B. Rapid detection of Shiga-toxin-producing Escherichia coli O157:H7 based on a colorimetric loop-mediated isothermal amplification (cLAMP) assay using a molecular beacon paired with HRPzyme. Anal Bioanal Chem. 2023;415(20):4973–84. pmid:37365333
- 33. Hardinge P, Murray JAH. Lack of specificity associated with using molecular beacons in loop mediated amplification assays. BMC Biotechnol. 2019;19(1):55. pmid:31370820
- 34. Kim SU, Batule BS, Mun H, Byun J-Y, Shim W-B, Kim M-G. Colorimetric molecular diagnosis of the HIV gag gene using DNAzyme and a complementary DNA-extended primer. Analyst. 2018;143(3):695–9. pmid:29299545.
- 35. Liu Z, Yao C, Wang Y, Yang C. A G-quadruplex DNAzyme-based LAMP biosensing platform for a novel colorimetric detection ofListeria monocytogenes. Anal Methods. 2018;10(8):848–54.
- 36. Zhu L, Xu Y, Cheng N, Xie P, Shao X, Huang K, et al. A facile cascade signal amplification strategy using DNAzyme loop-mediated isothermal amplification for the ultrasensitive colorimetric detection of Salmonella. Sens Actuat B: Chem. 2017;242:880–8.
- 37. Li W, Li Y, Liu Z, Lin B, Yi H, Xu F, et al. Insight into G-quadruplex-hemin DNAzyme/RNAzyme: adjacent adenine as the intramolecular species for remarkable enhancement of enzymatic activity. Nucleic Acids Res. 2016;44(15):7373–84. pmid:27422869
- 38. Bhuyan SK, Wang L, Jinata C, Kinghorn AB, Liu M, He W, et al. Directed evolution of a G-quadruplex peroxidase DNAzyme and application in proteomic DNAzyme-aptamer proximity labeling. J Am Chem Soc. 2023;145(23):12726–36. pmid:37276197
- 39. Cheng X, Liu X, Bing T, Cao Z, Shangguan D. General peroxidase activity of G-quadruplex-hemin complexes and its application in ligand screening. Biochemistry. 2009;48(33):7817–23. pmid:19618960
- 40. Dong H-J, Cho A-R, Hahn T-W, Cho S. Development of a multiplex loop-mediated isothermal amplification assay to detect shiga toxin-producing Escherichia coli in cattle. J Vet Sci. 2014;15(2):317–25. pmid:24675834
- 41. Zhao X, Li Y, Wang L, You L, Xu Z, Li L, et al. Development and application of a loop-mediated isothermal amplification method on rapid detection Escherichia coli O157 strains from food samples. Mol Biol Rep. 2010;37(5):2183–8. pmid:19685165
- 42.
SICASYS. Spotxel® Reader: Plate Reader & Microarray Image Analysis 2021 [8/16/2022]. 2021. Available from: https://www.sicasys.de/spotxel-reader/
- 43. Miller ND, Davidson PM, D’Souza DH. Real-time reverse-transcriptase PCR for Salmonella typhimurium detection from lettuce and tomatoes. LWT - Food Science and Technology. 2011;44(4):1088–97.
- 44. Beuchat LR, Farber JN, Garrett EH, Harris LJ, Parish ME, Suslow TV, et al. Standardization of a method to determine the efficacy of sanitizers in inactivating human pathogenic microorganisms on raw fruits and vegetables. Comp Rev Food Sci Food Safe. 2003;2(s1):174–8.
- 45. Poimenidou SV, Bikouli VC, Gardeli C, Mitsi C, Tarantilis PA, Nychas G-J, et al. Effect of single or combined chemical and natural antimicrobial interventions on Escherichia coli O157:H7, total microbiota and color of packaged spinach and lettuce. Int J Food Microbiol. 2016;220:6–18. pmid:26773252
- 46. Weagant SD, Bryant JL, Jinneman KG. An improved rapid technique for isolation of Escherichia coli O157:H7 from foods. J Food Prot. 1995;58(1):7–12. pmid:31121773
- 47. Lang MM, Harris LJ, Beuchat LR. Survival and recovery of Escherichia coli O157:H7, Salmonella, and Listeria monocytogenes on lettuce and parsley as affected by method of inoculation, time between inoculation and analysis, and treatment with chlorinated water. J Food Prot. 2004;67(6):1092–103. pmid:15222533
- 48. Wang F, Yang Q, Qu Y, Meng J, Ge B. Evaluation of a loop-mediated isothermal amplification suite for the rapid, reliable, and robust detection of Shiga toxin-producing Escherichia coli in produce. Appl Environ Microbiol. 2014;80(8):2516–25. pmid:24509927
- 49. U.S. Food and drug administration’s bacteriological analytical manual enrichment protocol for detection of Shiga toxin-producing E. coli on leafy vegetables. 2023. Available from: https://www.fda.gov/food/laboratory-methods-food/bam-chapter-4a-diarrheagenic-escherichia-coli
- 50. Leonard SR, Mammel MK, Lacher DW, Elkins CA. Application of metagenomic sequencing to food safety: detection of Shiga toxin-producing Escherichia coli on fresh bagged spinach. Appl Environ Microbiol. 2015;81(23):8183–91. pmid:26386062
- 51. Leonard SR, Mammel MK, Lacher DW, Elkins CA. Strain-level discrimination of Shiga toxin-producing Escherichia coli in spinach using metagenomic sequencing. PLoS One. 2016;11(12):e0167870. pmid:27930729
- 52. Luciani M, Di Febo T, Zilli K, Di Giannatale E, Armillotta G, Manna L, et al. Rapid detection and isolation of Escherichia coli O104:H4 from milk using monoclonal antibody-coated magnetic beads. Front Microbiol. 2016;7:942. pmid:27379071
- 53. Sharma B, Jain R. Right choice of a method for determination of cut-off values: a statistical tool for a diagnostic test. Asian J Med Sci. 2014;5(3):30–4.
- 54. Doyle MP. Escherichia coli O157:H7 and its significance in foods. Int J Food Microbiol. 1991;12(4):289–301. pmid:1854598
- 55. Denny J, Bhat M, Eckmann K. Outbreak of Escherichia coli O157:H7 associated with raw milk consumption in the Pacific Northwest. Foodborne Pathog Dis. 2008;5(3):321–8. pmid:18564912
- 56. Keene WE, Hedberg K, Herriott DE, Hancock DD, McKay RW, Barrett TJ, et al. A prolonged outbreak of Escherichia coli O157:H7 infections caused by commercially distributed raw milk. J Infect Dis. 1997;176(3):815–8. pmid:9291342
- 57. Vernozy-Rozand C, Mazuy-Cruchaudet C, Bavai C, Montet MP, Bonin V, Dernburg A, et al. Growth and survival of Escherichia coli O157:H7 during the manufacture and ripening of raw goat milk lactic cheeses. Int J Food Microbiol. 2005;105(1):83–8. pmid:16055219
- 58. Bottichio L, Keaton A, Thomas D, Fulton T, Tiffany A, Frick A, et al. Shiga toxin-producing Escherichia coli infections associated with romaine lettuce—United States, 2018. Clin Infect Dis. 2020;71(8):e323-e30.
- 59. Feng P. Shiga toxin-producing Escherichia coli (STEC) in fresh produce—a food safety dilemma. Microbiol Spectr. 2014;2(4):EHEC-0010-2013. pmid:26104197
- 60. Franz E, van Bruggen AHC. Ecology of E. coli O157:H7 and Salmonella enterica in the primary vegetable production chain. Crit Rev Microbiol. 2008;34(3–4):143–61. pmid:18728991
- 61. Herman KM, Hall AJ, Gould LH. Outbreaks attributed to fresh leafy vegetables, United States, 1973–2012. Epidemiol Infect. 2015;143(14):3011–21. pmid:25697407
- 62. Marshall KE, Hexemer A, Seelman SL, Fatica MK, Blessington T, Hajmeer M, et al. Lessons learned from a decade of investigations of shiga toxin-producing Escherichia coli outbreaks linked to leafy greens, United States and Canada. Emerg Infect Dis. 2020;26(10):2319–28. pmid:32946367
- 63. Kase JA, Borenstein S, Blodgett RJ, Feng PCH. Microbial quality of bagged baby spinach and romaine lettuce: effects of top versus bottom sampling. J Food Prot. 2012;75(1):132–6. pmid:22221365
- 64.
Organization WH. Microbiological Hazards in Fresh Leafy Vegetables and Herbs: Meeting Report. World Health Organization; 2008.
- 65. Sivapalasingam S, Friedman CR, Cohen L, Tauxe RV. Fresh produce: a growing cause of outbreaks of foodborne illness in the United States, 1973 through 1997. J Food Prot. 2004;67(10):2342–53. pmid:15508656
- 66.
CDC. Investigation Update: Multistate Outbreak of Human E. coli O145 Infections Linked to Shredded Romaine Lettuce from a Single Processing Facility. CDC: Atlanta, GA. Accessed 1 December 2013 2010.
- 67. Lalonde LF, Gajadhar AA. Optimization and validation of methods for isolation and real-time PCR identification of protozoan oocysts on leafy green vegetables and berry fruits. Food Waterborne Parasitol. 2016;2:1–7.
- 68. Li X, Zhang R, Wang C, Wang X, Yang Y, Cui S, et al. Use of β-cyclodextrin and milk protein-coated activated charcoal for rapid detection of Listeria monocytogenes in leafy greens by PCR without pre-enrichment. Food Control. 2022;140:109118.
- 69. Schrader C, Schielke A, Ellerbroek L, Johne R. PCR inhibitors – occurrence, properties and removal. J Appl Microbiol. 2012;113(5):1014–26. pmid:22747964
- 70. Ge B, Meng J. Advanced technologies for pathogen and toxin detection in foods: current applications and future directions. J Assoc Lab Autom. 2009;14(4):235–41.
- 71.
Whitaker R. Product testing: Considering the Issues. Produce Marketing Association: Newark, DE. 2011.
- 72. Baylis CL. Growth of pure cultures of verocytotoxin-producing Escherichia coli in a range of enrichment media. J Appl Microbiol. 2008;105(5):1259–65. pmid:18713293
- 73. Catarame TMG, O’Hanlon KA, Duffy G, Sheridan JJ, Blair IS, McDowell DA. Optimization of enrichment and plating procedures for the recovery of Escherichia coli O111 and O26 from minced beef. J Appl Microbiol. 2003;95(5):949–57. pmid:14633022
- 74.
Feng P, Weagant S, Jinneman K. Diarrheagenic Escherichia coli, chap. 4A. Bacteriological Analytical Manual. 2013. Available at: http://wwwfdagov/Food/FoodScienceResearch/LaboratoryMethods/ucm070080htm
- 75. Hein I, Flekna G, Krassnig M, Wagner M. Real-time PCR for the detection of Salmonella spp. in food: an alternative approach to a conventional PCR system suggested by the FOOD-PCR project. J Microbiol Methods. 2006;66(3):538–47. pmid:16564585
- 76. Bhunia AK. Biosensors and bio-based methods for the separation and detection of foodborne pathogens. Adv Food Nutr Res. 2008;54:1–44. pmid:18291303
- 77. Fedio WM, Jinneman KC, Yoshitomi KJ, Zapata R, Wendakoon CN, Browning P, et al. Detection of E. coli O157:H7 in raw ground beef by Pathatrix™ immunomagnetic-separation, real-time PCR and cultural methods. Int J Food Microbiol. 2011;148(2):87–92. pmid:21641670
- 78. Verstraete K, Robyn J, Del-Favero J, De Rijk P, Joris M-A, Herman L, et al. Evaluation of a multiplex-PCR detection in combination with an isolation method for STEC O26, O103, O111, O145 and sorbitol fermenting O157 in food. Food Microbiol. 2012;29(1):49–55. pmid:22029918
- 79. Weagant SD, Jinneman KC, Yoshitomi KJ, Zapata R, Fedio WM. Optimization and evaluation of a modified enrichment procedure combined with immunomagnetic separation for detection of E. coli O157:H7 from artificially contaminated alfalfa sprouts. Int J Food Microbiol. 2011;149(3):209–17. pmid:21784545
- 80. Johnson KE, Thorpe CM, Sears CL. The emerging clinical importance of non-O157 Shiga toxin-producing Escherichia coli. Clin Infect Dis. 2006;43(12):1587–95. pmid:17109294
- 81. Paton JC, Paton AW. Pathogenesis and diagnosis of Shiga toxin-producing Escherichia coli infections. Clin Microbiol Rev. 1998;11(3):450–79. pmid:9665978
- 82. Sewid AH, Dylewski HC, Ramos JH, Morgan BM, Gelalcha BD, D’Souza DH, et al. Colorimetric and electrochemical analysis of DNAzyme-LAMP amplicons for the detection of Escherichia coli in food matrices. Sci Rep. 2024;14(1):28942. pmid:39578633
- 83. Hussein HS. Prevalence and pathogenicity of Shiga toxin-producing Escherichia coli in beef cattle and their products. J Anim Sci. 2007;85(13 Suppl):E63–72. pmid:17060419
- 84. Bibbal D, Loukiadis E, Kérourédan M, Peytavin de Garam C, Ferré F, Cartier P, et al. Intimin gene (eae) subtype-based real-time PCR strategy for specific detection of Shiga toxin-producing Escherichia coli serotypes O157:H7, O26:H11, O103:H2, O111:H8, and O145:H28 in cattle feces. Appl Environ Microbiol. 2014;80(3):1177–84. pmid:24296503
- 85. Oswald E, Schmidt H, Morabito S, Karch H, Marchès O, Caprioli A. Typing of intimin genes in human and animal enterohemorrhagic and enteropathogenic Escherichia coli: characterization of a new intimin variant. Infect Immun. 2000;68(1):64–71. pmid:10603369
- 86. Tarr CL, Whittam TS. Molecular evolution of the intimin gene in O111 clones of pathogenic Escherichia coli. J Bacteriol. 2002;184(2):479–87. pmid:11751825
- 87. Yang X, Sun H, Fan R, Fu S, Zhang J, Matussek A, et al. Genetic diversity of the intimin gene (eae) in non-O157 Shiga toxin-producing Escherichia coli strains in China. Sci Rep. 2020;10(1):3275. pmid:32094410
- 88. Peng Y, Chen X, Yi G, Gao Z. Mechanism of the oxidation of organic dyes in the presence of nanoceria. Chem Commun (Camb). 2011;47(10):2916–8. pmid:21264416
- 89. Jiang R, Long B, Zeng G, Wang D, Fan H, Wu X. Loop-mediated isothermal amplification for detecting enterohemorrhagic Escherichia coli O157: H7: a comparison with PCR. J Southern Med Univ. 2012;32(7):1026–30.
- 90. Kouguchi Y, Fujiwara T, Teramoto M, Kuramoto M. Homogenous, real-time duplex loop-mediated isothermal amplification using a single fluorophore-labeled primer and an intercalator dye: Its application to the simultaneous detection of Shiga toxin genes 1 and 2 in Shiga toxigenic Escherichia coli isolates. Mol Cell Probes. 2010;24(4):190–5. pmid:20230890
- 91. Wang D, Liu F, Huo G, Ren D, Li Y. Development and evaluation of a loop‐mediated isothermal amplification method for detecting Escherichia coli O157 IN raw milk. Rapid Methods Autom Mic. 2009;17(1):55–66.
- 92. Zhao X, Wang J, Forghani F, Park J-H, Park M-S, Seo K-H, et al. Rapid detection of viable Escherichia coli O157 by coupling propidium monoazide with loop-mediated isothermal amplification. J Microbiol Biotechnol. 2013;23(12):1708–16. pmid:24002453
- 93. Zhu S, Chen Y, Wang Z, Jin D, Lu Q, Yao P. Detection of enterohemorrhagic Escherichia coli O157:H7 by loop-mediated isothermal amplification. Zhonghua Yu Fang Yi Xue Za Zhi. 2009;43(9):803–8. pmid:20137565
- 94. Wang Z, Cui X, Hu A, Lu Z, Meng F, Zhou L, et al. Establishment of real-time fluorescence and visual LAMP for rapid detection of Escherichia coli O157:H7 and kits construction. Lett Appl Microbiol. 2023;76(11):ovad122. pmid:37863833
- 95. Song J, Cha B, Moon J, Jang H, Kim S, Jang J, et al. Smartphone-based SARS-CoV-2 and variants detection system using colorimetric DNAzyme reaction triggered by loop-mediated isothermal amplification (LAMP) with clustered regularly interspaced short palindromic repeats (CRISPR). ACS Nano. 2022;16(7):11300–14. pmid:35735410
- 96. Aoi Y, Hosogai M, Tsuneda S. Real-time quantitative LAMP (loop-mediated isothermal amplification of DNA) as a simple method for monitoring ammonia-oxidizing bacteria. J Biotechnol. 2006;125(4):484–91. pmid:16790287
- 97. Chen S, Wang F, Beaulieu JC, Stein RE, Ge B. Rapid detection of viable salmonellae in produce by coupling propidium monoazide with loop-mediated isothermal amplification. Appl Environ Microbiol. 2011;77(12):4008–16. pmid:21498750
- 98. Gandelman OA, Church VL, Moore CA, Kiddle G, Carne CA, Parmar S, et al. Novel bioluminescent quantitative detection of nucleic acid amplification in real-time. PLoS One. 2010;5(11):e14155. pmid:21152399
- 99. Hardinge P, Murray JAH. Full dynamic range quantification using loop-mediated amplification (LAMP) by combining analysis of amplification timing and variance between replicates at low copy number. Sci Rep. 2020;10(1):916. pmid:31969573
- 100. Martínez-Castillo A, Muniesa M. Implications of free Shiga toxin-converting bacteriophages occurring outside bacteria for the evolution and the detection of Shiga toxin-producing Escherichia coli. Front Cell Infect Microbiol. 2014;4:46. pmid:24795866
- 101. Bumunang EW, McAllister TA, Zaheer R, Ortega Polo R, Stanford K, King R, et al. Characterization of Non-O157 Escherichia coli from cattle faecal samples in the North-West province of South Africa. Microorganisms. 2019;7(8):272. pmid:31434244
- 102. Joris M-A, Verstraete K, Reu KD, Zutter LD. Loss of vtx genes after the first subcultivation step of verocytotoxigenic Escherichia coli O157 and Non-O157 during isolation from naturally contaminated fecal samples. Toxins (Basel). 2011;3(6):672–7. pmid:22069733
- 103. Karch H, Meyer T, Rüssmann H, Heesemann J. Frequent loss of Shiga-like toxin genes in clinical isolates of Escherichia coli upon subcultivation. Infect Immun. 1992;60(8):3464–7. pmid:1639518
- 104. Senthakumaran T, Brandal LT, Lindstedt B-A, Jørgensen SB, Charnock C, Tunsjø HS. Implications of stx loss for clinical diagnostics of Shiga toxin-producing Escherichia coli. Eur J Clin Microbiol Infect Dis. 2018;37(12):2361–70. pmid:30267169
- 105. Mellmann A, Lu S, Karch H, Xu J, Harmsen D, Schmidt MA, et al. Recycling of Shiga toxin 2 genes in sorbitol-fermenting enterohemorrhagic Escherichia coli O157:NM. Appl Environ Microbiol. 2008;74(1):67–72. pmid:17981936
- 106. Castro VS, Ortega Polo R, Figueiredo EEDS, Bumunange EW, McAllister T, King R, et al. Inconsistent PCR detection of Shiga toxin-producing Escherichia coli: insights from whole genome sequence analyses. PLoS One. 2021;16(9):e0257168. pmid:34478476