Figures
Abstract
Due to the operation mode of traditional activated sludge systems, it is difficult for various functional bacteria to exert their respective advantages. In this study, immobilized fillers for hydrolytic acidification, nitrification, and denitrification were developed to allow independent operation at each stage, enhancing nitrogen removal performance of overall process. The results showed that ammonia nitrogen and total nitrogen levels in the effluent stabilized at 0.75–0.83 and 1.5–2 mg/L, respectively, when the total hydraulic retention time (HRT) of the system was 6.4 h and the nitrification unit HRT was 3 h. These values represented significant improvements compared with the traditional activated sludge process. Unit performance tests revealed that reducing the hydrolytic-acidification time to 0 min increased nitrite nitrogen and nitrate nitrogen levels in the effluent of unit A2 to 6.11 ± 0.2 mg/L and 3.67 ± 0.1 mg/L, respectively. This demonstrates that an active hydrolysis - acidification stage is the prerequisite for A2 to fully utilize raw organic matter in the water for remove nitrogen. When raw organic matter in the water bypassed the A2 unit and entered the O1 unit directly, ammonia oxidation rate (AOR) significantly decreased (from 0.32–0.33 to 0.22–0.23 kg/m3 ⋅ d), with further reduction at a low temperature (down to 0.11–0.12 kg/m3 ⋅ d). At this time, the AOR, unaffected by organic matter, decreased only slightly. This indicates that directing organic matter into the nitrification stage is essential for maintaining stability and resisting low temperatures. This process has certain guiding significance for improving nitrogen removal efficiency in municipal wastewater processes.
Citation: Liu X, Yang H, Wang J (2025) Optimizing nitrogen removal with an immobilized biological filler system: realizing stage-independent operational process. PLoS ONE 20(3): e0315864. https://doi.org/10.1371/journal.pone.0315864
Editor: Abdelamjeed Adam Lagum, Isra University, JORDAN
Received: August 21, 2024; Accepted: December 2, 2024; Published: March 5, 2025
Copyright: © 2025 Liu et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the manuscript and its Supporting Information files.
Funding: Xuyan Liu:Science Research Project of Hebei Education Department (QN2024036); Xuyan Liu:the Open Project Program of Hebei Center for Ecological and Environmental Geology Research (JSYF-202304); Hong Yang: the Beijing Municipal Commission of Education (Z161100004516015); Xuyan Liu: The Doctoral Research Start-up Fund of Hebei GEO University(BQ2024084). The sponsor or funder plays a role in research design, data collection and analysis, publication decisions or manuscript preparation.
Competing interests: The authors have declared that no competing interests exist.
Abbreviations:: TN, Total nitrogen; NH4 + -N, Ammonia nitrogen; NO2—N, Nitrite nitrogen; NO3—N, Nitrate nitrogen; COD, Chemical oxygen demand; DON, Dissolved organic nitrogen; DO, Dissolved oxygen; HRT, Hydraulic retention time; AOR, Ammonia oxidation rate; ARR, Ammonia nitrogen removal rate; NRR, TN removal rate; SEM, Scanning electron microscopy; VFAs, Volatile fatty acids
Introduction
Municipal sewage treatment plants use activated sludge to remove nitrogen and phosphorus from wastewater using bacterial hydrolytic acidification along with nitrifying, denitrifying, and polyphosphate-accumulating bacteria. In a single sludge system, pollutants are removed through three treatment units (anaerobic, anoxic, and aerobic). The processed water enters the sedimentation tank for solid-liquid separation and bacterial collection; it then flows back to the front end of the tank to retrieve biomass [1]. In this method, bacteria with different physiological characteristics and generation cycles function in the same system [2], which makes it difficult to leverage their respective advantages and results in lower overall treatment efficiency.
In the traditional activated sludge process, sludge reflux to maintain the biomass in the reaction system is generally employed, which inhibits the formation and maintenance of a strict anaerobic environment for hydrolysis-acidification bacteria. This makes it difficult to fully transform complex organic matter into simple organic matter and requires the addition of a carbon source. Furthermore, complex organic matter needs to be oxidized in the aerobic stage, which results in ineffective energy consumption. In addition, the influent dissolved organic nitrogen (DON) cannot be fully converted into NH4 + -N and removed, affecting overall treatment efficiency [3–5].
The biological effect of the traditional activated sludge method is highly contradictory. The specific operation mode results in a mixture of various functional bacteria, and the performance of those involved in nitrification and denitrification for nitrogen removal cannot be further improved [6,7]. In addition, since nitrifying bacteria have the longest reproduction cycle, longer hydraulic retention times (HRTs) and a higher sludge age (SRT) are required to ensure nitrification[8,9]; however, bacteria with a short reproduction cycle, such as phosphorus-accumulating bacteria, need to be continuously discharged to achieve good treatment results. This discharge decreases the number of nitrifying bacteria in the reactor, resulting in a decrease in overall nitrogen removal performance [10–12].
It is necessary to increase the overall sludge concentration or provide suitable conditions in traditional activated sludge treatment to better leverage the characteristics of certain bacteria. However, a high sludge concentration causes sludge swelling and loss. Attachment culturing is generally performed to obtain biofilms to achieve the separation of functional bacteria. However, owing to the inability to selectively control the types of attached bacteria, it is difficult to effectively separate various types of functional groups [13]. Immobilization technology has received widespread attention, as it facilitates the targeted cultivation of specific spatial areas through physical or chemical means, stabilizing the bacterial population while maintaining high activity and controlling species separation [14,15].
This study utilized urban sewage and immobilized hydrolytic acidification, nitrification, and denitrification fillers to build an anaerobic-anoxic-aerobic anoxic (AAOA) pilot nitrogen removal system. This system enabled the separation of different functional bacteria to fully utilize their respective properties and also solved the problems of the poor rate of influent organic matter utilization and low nitrogen removal efficiency seen in the traditional activated sludge process. The objectives were to determine the overall operation performance of the AAOA nitrogen removal system under different working conditions and seasonal temperature changes, along with the key control parameters, characterize each unit (including the influence of hydrolytic acidification on first-order denitrification performance and organic matter on nitrification performance), and analyze the internal structure of each filler. These results provide a basis for the efficient and stable removal of nitrogen from municipal sewage.
Materials and methods
Experimental water quality
The influent of the AAOA nitrogen removal pilot system originated from the primary sedimentation tank of the Beijing Gaobeidian Sewage Treatment Plant (Beijing, China). Table 1 provides an overview of the water quality of the influent.
Preparation of the immobilized filler
Polyvinyl alcohol was weighed and dissolved in water. It was then mixed with different bacteria, and auxiliary additives were added to form a relatively viscous embedded solution. The different bacterial auxiliary agents were added in different ways. Equipment was developed in the laboratory to pressure the concentrated mixed liquid to form a hollow cylinder that was cut into small sections. These sections were then placed in a solution of saturated boric acid for crosslinking and stabilization. Finally, they were cleaned with water to prepare immobilized fillers for hydrolytic acidification, nitrification, and denitrification. The filler had no skeleton and was a hollow cylinder approximately 1 cm wide and 2 mm thick [16–18].
Reactor setup and operation
The anaerobic-anoxic-aerobic-anoxic (AAOA) immobilized filler nitrogen removal system consisted of hydrolytic acidification, nitrification, and denitrification fillers that were components of a hydrolytic acidification unit (A1; effective volume 200 L), a primary denitrification unit (A2; effective volume 320 L), a nitrification unit (O1-O3; effective volume 200 L × 3), and a secondary denitrification unit (A3; effective volume 160 L); the total volume was 1.28 m3 (Fig 1). Influent water first entered unit A1 for hydrolysis and acidification to transform the complex organic matter into easily degradable organic matter and fully transform the DON. It subsequently entered unit A2 for denitrification by fully using influent COD and NO3--N. It then entered unit O, which was divided into three parts for gradient aeration; in this manner, NH4 + -N could be converted into NO3--N while controlling the DO that entered the denitrification compartment. Finally, it entered unit A3, and the remaining NO3--N was converted into N2.
Impacts of the working conditions on AAOA operation
The operating parameters of the system are shown in Table 2. The first phase was the stable operation phase, which was divided into three parts: the reflux ratio optimization stage (1 to 40 d), the HRT exploration stage (41 to 60 d), and the operation stage under seasonal temperature changes (61 to 120 d). The effects of reflux ratio, HRT, and seasonal temperature on the nitrogen removal of the AAOA fillers were investigated. The second phase was the low-temperature operation phase (121 to 160 d). The low-temperature operation of municipal sewage treatment is a bottleneck that needs to be solved, so this phase was investigated to improve the efficiency of this process.
Effect of organic matter on nitrification performance
The primary purpose of this study was to investigate the effect of organic matter on nitrification. By removing the first-stage denitrification (A2) unit, the influent water directly entered the O unit after passing through the A1 unit. This enabled a comparison to study the effect of organic matter on the performance of the nitrification unit. The schematic diagram of the process is shown in Fig 2, and the specific operation parameters are shown in Table 3.
Equations and calculations
The ammonia oxidation rate (AOR) and the ammonia nitrogen removal rate (ARR) were calculated using Equations 1, 2, and 3:
where (NH4 + -N)inf is the influent NH4 + -N concentration; (NH4 + -N)eff is the influent NH4 + -N concentration, and tHRT is the hydraulic retention time.
The TN removal rate (NRR) was calculated using Equation 4:
Where (TN)inf is the influent TN concentration, and (TN)eff is the influent TN concentration.
The distribution of TN in each part of the process was calculated as follows:
The daily N inflow was calculated from the inflow and the TN concentration, including DON, NH4 + -N, and NO3--N; the NO2--N concentration was negligible.
In the AAOA system, the N was removed through primary and secondary denitrification, and the TN amount in this stage was Mass TNA2,A3. Aerobic denitrification occurred in the nitrification stage, where TN was Mass TNo. Since the N removal system was composed of immobilized fillers and did not consider the residual sludge problem, the residual TN was taken as the final effluent N content. The formula for this calculation is as follows:
The daily effluent N level was calculated from the effluent flow and the TN concentration.
Analytical methods
The levels of NH4 + -N, NO2--N, NO3--N, and TN were determined using the national standard method (SEPAC, 2002) with Nessler reagent spectrophotometry, N-(1-naphthyl)-ethylenediamine spectrophotometry, ultraviolet spectrophotometry (UV-1600PC, MAPADA), and potassium persulfate oxidation ultraviolet spectrophotometry, respectively [19–21]. The COD level was determined using a rapid COD measuring instrument (Lianhua Technology, Shenzhen, China)[22].
Scanning electron microscopy (SEM)
We performed SEM to observe and analyze the internal structure of the immobilized fillers of each strain. Different immobilized fillers were obtained and immersed in the sampling tube with 2.5% glutaraldehyde, and the pH was adjusted to 6.8. The samples were fixed at 4 °C for 1.5 h and rinsed two to three times with 0.1 mol/L phosphoric acid buffer for 10 min each. The samples were then dehydrated with 50%, 70%, 80%, and 90% ethanol for 10–15 min in sequence and subsequently dehydrated three times with 100% ethanol for 10 to 15 min. The samples were replaced by a 1:1 mixture of ethanol and isoamyl acetate (v/v) and a pure solution of isoamyl acetate. Each incubation time was within 10–15 min. After replacement, the samples were placed in the dryer for > 8 h, and those with poor electrical conductivity were sprayed with gold. Finally, the treated samples were placed under the SEM, and the different positions and magnifications were adjusted according to the specific requirements. In all, 10–20 clear structural diagrams were obtained for analysis [23].
Community structure analysis
Bacterial 16S rRNA high-throughput sequencing was used to investigate the microbial community diversity of sludge. Illumina HiSeq 2500 PE250 (Illumina, San Diego, CA, USA) was used to amplify and sequence the V3–V4 region of bacterial 16 S rRNA, and Megan software was used to perform the environmental 16S sequence analysis. High-quality sequences of the corresponding samples were obtained and divided into different clustering operational taxonomic units (OTUs). Finally, the OTU results were analyzed and calculated [24,25].
Results and discussion
Impacts of working conditions on the operation of the AAOA system
Impact of reflux ratio.
We tested to select the most suitable internal reflux ratio (R) (80%, 90%, 100%, and 110%) over 40 d of operation. The apparent NH4 + -N value of each unit of the system was diluted by reflux. On days 1 to 10, when R was 80%, the concentration of NH4 + -N in the effluent of unit A2 ranged from 23.16 to 24.89 mg/L; simultaneously, the concentration of NH4 + -N in the effluent of the O1 unit decreased to 15.03–16.56 mg/L. According to Equation 2, the AOR value at this time was between 0.25 and 0.26 kg/m3·d, and the ARR ranged from 32% to 34%. The concentration of NH4 + -N in the effluent water of the O2 unit was further reduced to 5.75–6.33 mg/L; the AOR value was 0.42–0.44 kg/m3·d, and the ARR was 61.7–64.6%. After entering the O3 treatment unit, the concentration of NH4 + -N decreased to 0.82–0.97 mg/L; the AOR value was 0.21–0.23 kg/m3·d, and the ARR was as high as 83.7–86.5%. In addition, the effluent COD concentration of the A2 treatment unit was 64.4–70.5 mg/L.
When R increased to 90% (11–20 d), the NH4 + -N effluent of O1 decreased to 13.38–13.5 mg/L and the AOR increased to 0.33–0.35 kg/m3·d compared to those seen with R at 80%. At this time, the COD of the A2 effluent was 45.5–48.3 mg/L, which indicated that the COD had an impact on the AOR of O1. When R was 90%, A2 had sufficient NO3--N for denitrification and largely consumed the influent COD. This impeded the growth of the heterotrophic bacteria that were introduced into the system through the influent because they could not fully use the COD during the aerobic stage, meaning they could not compete with the nitrifying bacteria for dissolved oxygen [26,27]. At this time, there was little change in the ARR and AOR of O2 and O3, and the NH4 + -N in the effluent remained below 1 mg/L. When R increased to 100% (d 21–30), the COD of the A2 effluent was 45.67–47.89 mg/L, which was not significantly different from the previous stage, indicating that there was a negative effect on the degradation of organic matter. With the degradation effect in the aerobic stage, the COD of the O3 effluent was reduced to 31.67–33.19 mg/L, whereas the ARR of O1 in this stage remained at 0.33–0.35 kg/m3·d. Similarly, when R increased to 110% (31–40 d), the ARR of O1 remained unchanged, and the NH4 + -N level in the effluent from both stages remained below 1 mg/L. This indicated that when R was 90%, the NO3--N reflux generated by the nitrification unit was sufficient for A2 to consume most of the easily degradable COD in the influent water. However, an additional increase of R did not considerably improve the performance of the entire nitrification unit but increased its energy consumption [28–30]. From these results, an R-value of 90% was deemed the most suitable.
The changes in TN of each unit in the AAOA system are shown in Fig 3(c). From days 1 to 10, when R was 80%, there was less NO2--N and NO3--N in the A2 effluent compared with traditional process, and the TN in the O1 effluent decreased by approximately 3.5 mg/L compared to A2. The NRR was 13.75%–14.33%. The NRR of O2 was 9.49%–9.96%, whereas the NRR of O3 was only 3%–4%. The TN of the A3 effluent was 1.59–2.05 mg/L. When R increased to 90%, the NO2--N and NO3--N levels in the A2 effluent increased by 0.68–0.8 and 0.98–1.03 mg/L, respectively. At this time, the NRR of O1 was reduced to 4.56%–4.69%; the NRR of O2 and O3 was only 3%–4%, and the TN of the A3 effluent was 1.5–2 mg/L. These findings indicate that when R ranged from 90% to 80%, the easily degradable organic matter in the influent was fully utilized. This not only prevented the nitrification unit from being affected by the presence of COD but also reduced the effect of aerobic denitrification, resulting in a decrease in the variation of effluent TN in each unit [31,32]. When R increased to 100% and 110%, the NO2--N and NO3--N levels in the A2 effluent increased slightly, which was related to insufficient levels of CODs in the influent. For the nitrification unit, the consumption of COD resulted in a small variation in effluent TN, and owing to the increase in R, the inlet load of A3 was reduced, and the effluent TN could be maintained at a low level [33,34].
(a) Changes in NH4 + -N. (b) AOR and ARR. (c) Changes in TN ((AAOA: Anaerobic - anoxic - aerobic - anoxic; NH4 + -N: Ammonia nitrogen; AOR: Ammonia oxidation rate; ARR: Ammonia removal rate).
Impact of HRT.
The effect of HRT on the system was also assessed. The first stage (P1) occurred from days 11 to 21, with a total HRT of 6.4 h and a nitrification unit HRT of 3 h. The second stage (P2) lasted from days 41 to 50; the total HRT was 4.82 h, and the nitrification unit HRT was 2.27 h. The third stage (P3) was from days 51 to 60, with a total HRT of 3.2 h and a nitrification unit HRT of 1.5 h. The specific operation parameters are shown in Table 2.
The influence of HRT on the operation of the nitrification unit is shown in Fig. 4(a,b). During the P1 stage, the nitrification units performed well, with an AOR of 0.27–0.28, 0.47–0.48, and 0.16–0.18 kg/m3·d and an ARR of 39%–40%, 69%–70%, and 79%–80%, respectively. The effluent NH4 + -N of the nitrification unit stabilized at 0.78 mg/L. When the HRT of the nitrification unit was reduced to 2.27 h, and the reaction time of each unit was 0.75 h, the nitrification unit performed well and even exceeded the performance of the previous stage at certain points (days 46–48). The COD of each unit’s effluent increased compared to that of the previous stage: that of O1 increased from 47.3 to 53.4 mg/L, that of O2 increased from 43.3 to 49.8 mg/L, and that of O3 increased from 36.2 to 44.9 mg/L. When the HRT of the nitrification unit was reduced to 2.27 h, the performance did not decrease but the concentration of COD in the effluent increased, which indicated that aerobic denitrification was easily affected by HRT [34,35]. When the HRT was further reduced to 1.5 h, the effluent NH4 + -N of the nitrification unit increased greatly and reached 3.89 mg/L on day 60. The AOR decreased to 0.12–0.13, 0.43–0.44, and 0.17–0.18 kg/m3·d, and the ARR decreased to 31.4%–32.7%, 52.5%–53.4%, and 45.3%–46.3%, respectively. This indicated that there was insufficient time for the reaction to proceed.
(a) Changes in NH4+-N concentration; (b) AOR and ARR; (c) changes in TN (AAOA: anaerobic - anoxic - aerobic - anoxic; HRT: hydraulic retention time; NH4+-N: ammonia nitrogen; AOR: ammonia oxidation rate; ARR: ammonia removal rate).
At an HRT of 6.4 h, the units of the AAOA system performed well (Fig 4 (c)). There were low concentrations of NO2--N and NO3--N in the A2 effluent, and the NRR of the nitrification units was between 4.5% and 5.0%. The TN in the A3 effluent ranged between 1.76 and 1.89 mg/L, and the NRR was between 90.79% and 91.92%. The performance remained stable when the HRT was decreased to 4.82 h. There were low concentrations of NO2--N and NO3--N in the effluent of A3. However, the residual TN was 4.83–5.01 mg/L, and the NRR decreased to 75.6%–76.2%. When the HRT decreased to 3.2 h, NO2--N accumulated in the A2 unit and the NRR in the nitrification unit decreased to 2.09%–2.56%, indicating that aerobic denitrification had diminished. The TN that remained in the effluent of A3 was 7.0–7.3 mg/L. Combined with the previous analysis of the changes of NH4 + -N, the NH4 + -N concentration at this time was found to include DON transformation. The residual NO3--N concentration of the denitrification unit was approximately 3.5–3.6 mg/L.
Based on these results, each unit maintained a good state at an HRT of 6.4 h. When the HRT decreased to 4.82 h, the HRT of the nitrification unit was 2.27 h. At this time, the nitrification unit still maintained high levels of AOR and ARR, but there was residual TN in the effluent of A3. The concentrations of NO2--N and NO3--N remained low, which indicated that the reaction time of A1 was too short. This resulted in residual DON and an increase in effluent TN. As the HRT further decreased to 3.2 h, the nitrification stage HRT was only 1.5 h. At this time, although NH4 + -N and TN residues appeared in the effluent, the national Class A standard was still met. This indicated that the fillers in the AAOA system facilitated efficient nitrification and denitrification. However, to ensure a stable and efficient operation of the system, a total HRT of 6.4 h and a nitrification unit HRT of 3 h were selected in the subsequent stages to maximize the performance of each unit [36].
Impact of temperature.
In this study, the operational performance of the system under seasonal temperature changes and low temperatures in winter was explored (61 to 120 d). The specific operating parameters are shown in Table 2.
The temperature gradually decreased from days 61 to 100. In the early stage of seasonal temperature changes, the performance of each nitrification unit did not change considerably, and the AOR of O1, O2, and O3 remained at 0.32–0.35, 0.46–0.48, and 0.15–0.17 kg/m3·d, respectively. The levels of ARR1, ARR2, and ARR3 reached 38%–39%, 69%–70%, and 79%–80%, respectively, and the effluent NH4 + -N remained below 1 mg/L. When the temperature decreased to 17 °C, the effluent NH4 + -N level started to increase; the AOR of O1 and O2 decreased to 0.28–0.29 and 0.34–0.35 kg/m3·d, respectively, and the AOR of O3 increased to 0.18–0.19 kg/m3·d. These changes were related to the increase in the effluent load of the previous unit owing to the lower temperature. The ARR decreased to 34%–35%, 47%–48%, and 51%–52%, respectively, and the effluent level of the nitrification unit increased to 3.67 mg/L, indicating that when the temperature reached 17 °C, it negatively affected the performance of the filler. When the temperature decreased to < 14 °C, the level of effluent in O3 increased to 3.96 mg/L. At this time, the system entered the low-temperature operation stage; the AOR was stabilized at 0.32–0.33, 0.33–0.34, and 0.18–0.19 kg/m3·d, respectively, and the effluent NH4 + -N decreased to 3.42 mg/L and remained stable (Fig 5). This indicated that the nitrifying fillers in the AAOA system could maintain high activity when experiencing seasonal temperature changes, though system performance was affected to some extent at temperatures below 17 °C, and temperatures below 14 °C substantially affected performance. However, by adjusting the operating conditions, the effluent levels still met the national Class A standard [37].
(a) changes in the NH4+-N concentration; (b) ammonia oxidation rate and removal rate; (c) changes in the TN concentration (AAOA: anaerobic - anoxic - aerobic - anoxic; NH4+-N: ammonia nitrogen; TN: total nitrogen ).
When the temperature decreased seasonally, the NRR of each unit remained stable, and there were low effluent nitrogen levels in A2 (Fig 5(c)): the level of NO2--N was 0.73–0.75 mg/L, that of NO3--N was stable at 0.95–1.01 mg/L, and the effluent TN was 22.9–23.1 mg/L. After the O unit reaction, the NRR1 was 4.7%, whereas the NRR2 and NRR3 levels were 5.1% and 3.6%, respectively. These values indicated that aerobic denitrification occurred in the nitrification unit. The final effluent TN of A3 remained at approximately 1.5 mg/L, and the NRR4 was 94%. When the temperature decreased to 14.2 °C (14 d), the TN in the A3 effluent began to increase; when the temperature dropped below 13.6 °C, the increase was 5.03 mg/L, and the NRR4 was 70.3%–70.5%. However, the NRR of the nitrification units increased in the low-temperature operation stage because the effect of aerobic denitrification was enhanced after the adjustment of the operating conditions; the extended HRT was 4.5–5 h. These results indicate that the denitrification filler was strongly resistant to low temperatures and could maintain stable treatment; although the performance decreased when the temperature decreased to 14 °C or lower, the Class A requirements were still met.
Nitrogen changes along the AAOA system
After the action of A1, the mean value of NH4 + -N increased from 35.67 to 40.66 mg/L, whereas the levels of TN, NO2--N, and NO3--N changed only slightly, and the COD decreased from 139.2 to 125.4 mg/L. This indicated that the DON conversion was approximately 5 mg/L in the hydrolytic acidification stage. After the action of the A2 unit, the effluent TN remained at 24.66 mg/L and the COD at 46.77 mg/L. After the nitrification unit reaction, only 0.76 mg/L of the NH4 + -N remained in the effluent of O3, and the nitrogen removal capacity of aerobic denitrification in O1, O2, and O3 accounted for 4.74%, 3.46%, and 3.0% of the total nitrogen removal capacity, respectively. This shows that the contribution of aerobic denitrification to the nitrogen removal of O1 did not differ considerably from that of O2 and O3, indicating that unit A2 fully utilized the influent organic matter with little impact on O1. Aerobic denitrification accounted for 11.2% of the total nitrogen removal of the whole unit. After the A3 unit, the levels of TN and NH4 + -N were 1.89 and 0.26 mg/L, respectively, and the COD concentration was 28.15 mg/L. Unit A3 played a significant role in ensuring that the final discharge met the requirements. Primary and secondary denitrification in the AAOA system accounted for 43.1% and 42.08% of the total nitrogen removal, respectively, and for 85.18% as a whole (Fig 6).
In this system, the role of primary denitrification is to fully utilize the organic matter brought by the influent as a carbon source, while the role of secondary denitrification is to ensure the final effluent. Because of this, primary and secondary denitrification are both important to total nitrogen removal. According to Equations 5 to 7, the total amount of nitrogen removed from the AAOA system in the stable period was 235.5 g/d; the total amount of nitrogen removed by aerobic denitrification was 26.37 g/d, while 200.62 g/d was removed by denitrification.
Impact of organic matter on the performance of nitrification
The impact of organic matter on the performance of nitrification units in the AAOA and AOA systems was explored by a comparison of their performance. The specific operational performance of the AOA system is shown in the supporting materials (S1 Fig).
The stages were > 17 °C, from 17–14 °C, and < 14 °C. The mean values of O1, O2, and O3 in AAOA and AOA during these stages were named either A or F (for AAOA or AOA, respectively);1, 2, or 3 for O1, O2, and O3, respectively, and -1, -2, -3 for each stage, respectively; for example, AAOA O1 at < 14 °C was named A1-3.
The AOA system lacked A2 units, meaning that influent organic matter affects the AOR value of the O1 unit (Fig 7). When the temperature was > 17 °C, the AOR and ARR of the O1 unit were 0.22–0.23 kg/m3·d and 17.5%, whereas those of the O1 unit of the AAOA were 0.32–0.33 kg/m3 ⋅ d and 38.7%, respectively. As the temperature decreased from 17 ºC to 14 °C, the AOR and ARR of the O1 unit in the AOA decreased to 0.17–0.18 kg/m3 ⋅ d and 12.9%, respectively. When the temperature decreased further to < 14 °C, the levels of AOR and ARR levels decreased again to 0.11–0.12 kg/m3 ⋅ d and 13.0%, respectively. Compared to the AAOA at low temperatures, the AOR and ARR in the AOA only decreased slightly. The O1 unit of AOA was highly affected by temperature. This indicated that when the influent organic matter entered the nitrification unit, the heterotrophic bacteria competed with the nitrifying bacteria for DO, affecting nitrification efficiency and reducing their ability to resist low temperatures [38]. The ammonia oxidation performance of O2 and O3 in the AOA was significantly improved and reached levels greater than those in the AAOA. This indicated that once the organic matter consumption of the AOA O1 unit was complete, the subsequent fillers still had high activity; this was related to the low O1 performance and high NH4 + -N concentration in the effluent. A comparison of the NRR of the O1 unit between AOA and AAOA showed that there was a significantly larger NRR in the AOA. This was attributed to the use of influent organic matter for denitrification by the aerobic denitrifying bacteria, which resulted in an NRR level of 14.5%. Within the temperature range of 17–14 °C, the NRR still maintained a high level (14.7%). However, when the temperature dropped < 14 °C, the NRR decreased to 5.0%, indicating a decrease in the performance of aerobic denitrifying bacteria.
As shown above, the O1 performance of the AOA system decreased significantly owing to the influence of influent organic matter, and the system was less resistant to low temperatures than the AAOA system. These findings indicate that controlling the amount of organic matter that enters the nitrification stage is also an important factor in maintaining the stability of the nitrification unit.
Impact of hydrolytic acidification on the performance of the primary denitrification unit
The impact of the A1 unit performance on the A2 unit is shown in Fig 8. After 60 min of hydrolysis and acidification, the concentrations of NO2--N and NO3--N in the A2 effluent were both lower (0.75 and 0.96 mg/L, respectively), and the TN decreased from 42.1 ± 0.5 mg/L in the influent to 22.56 ± 0.2 mg/L. As the reaction time of A1 decreased (30 min), the concentrations of NO2--N and NO3--N in the effluent of A2 increased to 3.62 ± 0.2 and 2.1 ± 0.1 mg/L, respectively. This indicated that the amount of simple organic matter remaining after hydrolysis and acidification was no longer sufficient to fuel denitrification, leading to the accumulation of NO2--N; when the hydrolysis-acidification reaction ceased and the influent directly entered A2, the NO2--N accumulated to 6.11 ± 0.2 mg/L. In addition, the NO3--N increased to 3.67 ± 0.1 mg/L. Owing to the lack of hydrolysis and acidification, the biodegradability of the influent could not be increased, which resulted in a decrease in the efficiency of denitrification. Overall, these results indicate that the hydrolysis and acidification stage has a significant impact on the performance of A2. Chang et al (2001) [39] found that the amount of rapidly degradable organic matter in the COD of raw water in urban sewage accounted for 19.19% of the total COD, soluble inert organic matter (non-biodegradable) accounted for 9.74%, suspended inert organic matter (non-biodegradable) accounted for 4.21%, and the active microbial components accounted for 7.27%; the largest proportion was suspended slowly-degradable organic matter, which accounted for 59.59%. However, Pai (2007) [40] found that the NO3--N in the A2O anoxic pool decreased from 12.41 to 8.4 mg/L, which indicated a low removal efficiency, possibly caused by the poor hydrolysis and acidification of the A2O anaerobic segment. The results indicate that a hydrolysis-acidification section that performs well can transform the organic matter that is generally resistant to degradation into an available carbon source for denitrification; in contrast, a hydrolysis-acidification section that performs poorly will reduce denitrification efficiency and increase the reaction time. The hydrolysis and acidification performance of the anaerobic section in the common A2O process was poor, which explains the difficulties in improving the nitrogen removal effect of the anoxic section.
Internal structure of fillers
The internal structures of the nitrification and denitrification fillers were observed by SEM. The electron microscope images of nitrifying fillers were magnified by 2k, 5k, 10k, and 20k, respectively (Fig 9a–d). The overall structure of the embedded nitrification filler was characterized by a tight network structure, with large numbers of bacteria in the gaps (Fig 9(a)(b)). This structure facilitates the adhesion of bacteria and provides space for bacterial growth, which is also the reason why the immobilized filler produces less mud [41,42]. The main types of bacteria in the nitrifying filler were ellipsoidal and rod-shaped bacteria (Fig 9(c),(d)). Zhao et al. (2018) [43] found that the nitrite bacteria are primarily spherical. The morphology of the bacterial cells in the figure suggests that Nitrosococcus could be found here. The main forms of ammonia-oxidizing bacteria (AOB) are spherical, ellipsoidal, rod-shaped, tightly spiraled, and slender arcs. The main forms of nitrite-oxidizing bacteria (NOB) are spherical, pear-shaped, slender rod-shaped, multi-shaped rod-shaped, and loose spirals. The electron microscopy images of denitrification fillers at different magnifications (Fig 9(e-h)) showed that the internal structure of the also contained numerous bacteria, most of which were rod-shaped (Fig 9(e)). Wong et al. (2005) [44] found that most of the immobilized fillers were occupied by rod-shaped denitrifying bacteria, with a small number of spherical bacteria, which is consistent with the findings of this study.
Comparative analysis of the community structure involved in primary and secondary denitrification
Fig 10 shows the abundance of bacteria that were involved in primary and secondary denitrification in the AAOA system to compare the differences in community structure during the long-term operation of denitrification fillers with different carbon sources. The denitrifying bacteria in A2 and A3 primarily included Arcobacter, Thauera, Comamonas, Thiobacillus, Pseudomonas, Azoarcus, Flavobacterium, Defluviimonas, and Thermomonas, with little difference between the two; however, there were differences in abundance. In A2 and A3, Arcobacter, Thauera, and Comamonas predominated; the abundance of Arcobacter was 14.34 and 21.23%, respectively. Pseudomonas and Thauera were typical concurrent autotrophic denitrifying bacteria, while Arcobacter, Thiobacillus, and Azoarcus were the primary autotrophic denitrifying microorganisms. High-throughput sequencing previously identified Thauera and Paracoccus in the denitrifying immobilized filler as the predominant bacterial genera. The abundance of denitrifying bacteria commonly found in wastewater treatment plants, such as Pseudomonas and Comamonas, increased significantly with the operation in actual sewage. The denitrification properties of Flavobacterium, Defluviimonas, and Thermomonas have also been verified, and these three bacteria are more abundant in A3 than A2.
In addition to the dominant denitrifying bacteria in A2 and A3, some bacterial genera capable of hydrolysis-acidification were also found, including Ornatilinea, Longilinea, Ignavibacterium, and Anaerolinea. Ornatilinea has been shown to ferment sugars and amino acids and then convert them into acetic acid and other volatile fatty acids. Longilinea can metabolize a variety of carbohydrates, and Anaerolinea can metabolize a variety of carbohydrates to produce organic acids. The various hydrolysis-acidification strains were more abundant in A2 than in A3; the abundance of Ornatilinea was 4.45% and 1.34%, respectively, and that of Longilinea was 2.22% and 0.67%. The reason for this is that A2 primarily utilizes the organic matter in raw water as a carbon source; although there is a hydrolysis-acidification unit, owing to fluctuations in actual sewage quality, there may still be some complex organic matter that enters the system, leading to an increase in the abundance of some hydrolysis-acidification bacteria. A3 primarily utilizes sodium acetate as a carbon source, so there were relatively few hydrolytic acidification functional bacteria present. Some common bacterial genera were found at similar levels in these two reactors.
Analysis of the community structure of nitrification units.
As shown in Fig. 11, the nitrobacteria in O1, O2, and O3 primarily included Nitrosomonas, Nitrobacter, and Nitrospira. The nitrobacteria in O2 were highly abundant. Nitrosomonas was the most abundant (25.36%), followed by Nitrobacter (7.44%), Nitrospira (2.67%), and Nitrolancea (2.62%). There were fewer Nitrosomonas in O1 (18.3%) than in O2. Some studies have found that high DO is more conducive to the enrichment of Nitrosomonas and Nitrospira; this is different from the results in this study, possibly because the small amount of organic matter in the A2 effluent may have affected the abundance of some nitrobacteria. The nitrobacteria in O3 were similarly abundant to those of O1 but lower in abundance than those of O2. This may be because of the high performance of O2, which led to a low concentration of matrix that entered O3, resulting in a decrease in bacterial abundance under the action of long-term low load. As shown in Fig. 11, there were still aerobic denitrifying bacteria. Paracoccus was less abundant in O1, O2, and O3, although it was more abundant in O1 than in O2 and O3. Although the AAOA system has an A2 unit to utilize COD in raw water, a small amount of organic matter could enter the nitrification unit, meaning that a small amount of aerobic denitrification could occur. As previously shown, aerobic denitrification bacteria were present in immobilized inoculation sludge. The reason for the reduction in abundance is also related to their small role in the system. Ignavibacterium was also less abundant in the system, though it was more abundant in O1 (0.35%) than in O2 and O3. These differences can also be attributed to the influent COD.
Implications
The AAOA system utilizes immobilized biological fillers in the anaerobic hydrolysis and acidification section. Because it does not require sludge reflux to maintain biomass, it maintains a good anaerobic state to fully promote hydrolysis and acidification. The traditional A2O, MBR process and the combination process with a separate hydrolysis and acidification tank all require sludge reflux, which makes it difficult to maintain an effective anaerobic state. The AAOA system has a primary denitrification stage, meaning that less organic matter enters the nitrification stage. The direct entry of organic matter into the nitrification unit in traditional systems has a greater impact on the performance of nitrifying bacteria; competition between heterotrophic and nitrifying bacteria results in reduced ammonia-nitrogen oxidation rates. However, owing to the poor performance of the anaerobic hydrolysis and acidification stage in the traditional nitrogen removal process, denitrification in the anoxic section is insufficient. Because of this, the organic matter in the aerobic section needs to be removed, which will inevitably affect the performance of nitrifying bacteria.
Compared with the traditional nitrogen removal process, the AAOA system is effective at removing nitrogen because of the setting of the primary denitrification stage of hydrolytic acidification. This ensures the full use of influent organic matter, reducing the concentration that enters the nitrification stage as much as possible. Consequently, there are no limitations on the performance of nitrifying bacteria, resulting in better overall nitrogen removal performance.
Conclusion
To solve the key core problems facing traditional activated sludge treatment of municipal wastewater, such as low biochemical efficiency and raw organic matter utilization rate, an AAOA nitrogen removal system was constructed and the characteristics and overall performance of each unit were systematically studied. This new system provides an effective method for the removal of nitrogen from municipal wastewater. Compared with existing biological nitrogen removal processes, AAOA was more effective. When the total HRT of the system was 6.4 h and that of the nitrification unit HRT was 3 h, the effluent NH4 + -N was stabilized at 0.78–0.84 mg/L, and the TN reached 1.5–2 mg/L. When the system R was 90%, the AOR of O1 was increased by 0.33–0.35 kg/m3 ⋅ d; the effluent COD of A1 was 45.5-48.3 mg/L, and the NH4 + -N remained below 1 mg/L. At low temperatures (<14 °C), the NH4 + -N and TN of the effluent still met the national standard Class A standard.
Organic matter can still affect the performance of the nitrification unit. Although the nitrification filler contains highly efficient nitrifying bacteria, the heterotrophic bacteria in sewage will affect the oxidation of NH4 + -N when there is abundant organic matter. First-stage denitrification is necessary in the AAOA system, which was particularly seen during quarterly temperature changes. Above 17 °C, the AOR and ARR of AOA were 0.22–0.23 kg/m3 ⋅ d and 17.5%, respectively, while those of the AAOA were 0.32–0.33 kg/m3 ⋅ d and 8.7%, respectively. When the temperature decreased to 17 °C or lower, the AOR and ARR of AOA decreased to 0.11–0.12 kg/m3 ⋅ d and 13.0%, respectively, while those of the AAOA only slightly decreased. The change in the organic composition of raw water through altering the HRT of A1 to 60 minutes was crucial to improving denitrification performance and maintaining effluent NO2--N and NO3--N at a low level.
The AAOA pilot process demonstrates effective biological nitrogen removal and addresses key challenges that the traditional process struggles to overcome, offering valuable insights for process improvement.
Acknowledgments
We are very grateful to the sample testing companies involved in this study for their cooperation in sampling.
References
- 1. Satoh H, Ono H, Rulin B, Kamo J, Okabe S, Fukushi K-I. Macroscale and microscale analyses of nitrification and denitrification in biofilms attached on membrane aerated biofilm reactors. Water Res. 2004;38(6):1633–41. pmid:15016541
- 2. Shi K, Liang B, Cheng H-Y, Wang H-C, Liu W-Z, Li Z-L, et al. Regulating microbial redox reactions towards enhanced removal of refractory organic nitrogen from wastewater. Water Res. 2024;258:121778. pmid:38795549
- 3. Mishra S, Singh V, Cheng L, Hussain A, Ormeci B. Nitrogen removal from wastewater: A comprehensive review of biological nitrogen removal processes, critical operation parameters and bioreactor design. J Environ Chemical Eng. 2022;10(3):107387.
- 4. Roots P, Sabba F, Rosenthal AF, Wang Y, Yuan Q, Rieger L, et al. Integrated shortcut nitrogen and biological phosphorus removal from mainstream wastewater: process operation and modeling. Environ Sci: Water Res Technol. 2020;6(3):566–80.
- 5. Zanetti L, Frison N, Nota E, Tomizioli M, Bolzonella D, Fatone F. Progress in real-time control applied to biological nitrogen removal from wastewater. A short-review. Desalination. 2012;286:1–7.
- 6. Lagum AA. Integrated electro-anammox process for nitrogen removal from wastewater. Int J Environ Sci Technol. 2023;20(12):13061–72.
- 7. Zhang X, Liu Y. Circular economy-driven ammonium recovery from municipal wastewater: state of the art, challenges and solutions forward. Bioresour Technol. 2021;334:125231. pmid:33962161
- 8. Cruddas PH, Asproulis N, Antoniadis A, Best D, Collins G, Porca E, et al. The impact of hydraulic retention time on the performance of two configurations of anaerobic pond for municipal sewage treatment. Environ Technol. 20211–14. pmid:34057403
- 9. Pasalari H, Gholami M, Rezaee A, Esrafili A, Farzadkia M. Perspectives on microbial community in anaerobic digestion with emphasis on environmental parameters: a systematic review. Chemosphere. 2021;270:128618. pmid:33121817
- 10. Moretto G, Ardolino F, Piasentin A, Girotto L, Cecchi F. Integrated anaerobic codigestion system for the organic fraction of municipal solid waste and sewage sludge treatment: an Italian case study. J Chemical Tech Biotech. 2019;95(2):418–26.
- 11. Oehmen A, Zeng RJ, Yuan Z, Keller J. Anaerobic metabolism of propionate by polyphosphate-accumulating organisms in enhanced biological phosphorus removal systems. Biotechnol Bioeng. 2005;91(1):43–53. pmid:15880463
- 12. Cheng C, Zhou Z, Qiu Z, Yang J, Wu W, Pang H, et al. Enhancement of sludge reduction by ultrasonic pretreatment and packing carriers in the anaerobic side-stream reactor: Performance, sludge characteristics and microbial community structure. Bioresour Technol. 2018;249:298–306. pmid:29054059
- 13. Zhang Y, Zhang L, Guo B, Zhou Y, Gao M, Sharaf A, et al. Granular activated carbon stimulated microbial physiological changes for enhanced anaerobic digestion of municipal sewage. Chem Eng J. 2020;400:125838.
- 14. Xie Z, Wang Z, Wang Q, Zhu C, Wu Z. An anaerobic dynamic membrane bioreactor (AnDMBR) for landfill leachate treatment: performance and microbial community identification. Bioresour Technol. 2014;161:29–39. pmid:24681530
- 15. Rostron WM, Stuckey DC, Young AA. Nitrification of high strength ammonia wastewaters: comparative study of immobilisation media. Water Res. 2001;35(5):1169–78. pmid:11268837
- 16. Sam SP, Adnan R, Ng SL. Statistical optimization of immobilization of activated sludge in PVA/alginate cryogel beads using response surface methodology for p-nitrophenol biodegradation. J Water Process Eng. 2021;39:101725.
- 17. Magrí A, Vanotti MB, Szögi AA. Anammox sludge immobilized in polyvinyl alcohol (PVA) cryogel carriers. Bioresour Technol. 2012;114:231–40. pmid:22520223
- 18. Wang X, Yang H, Zhou Y, Liu X. Performance and mechanism analysis of gel immobilized anammox bacteria in treating different proportions of domestic wastewater: a valid alternative to granular sludge. Bioresour Technol. 2022;347:126623. pmid:35017093
- 19. Tringe SG, Rubin EM. Metagenomics: DNA sequencing of environmental samples. Nat Rev Genet. 2005;6(11):805–14. pmid:16304596
- 20. Pandi GJ, Raja K, Vijayan V, Sudhagar S. Investigation on the mechanical, water absorption, and tribological performance of calotropis gigantea and abaca fiber reinforced epoxy composites. J Polym Res. 2024;31(10).
- 21. Zhang J, Zhou J, Han Y, Zhang X. Start-up and bacterial communities of single-stage nitrogen removal using anammox and partial nitritation (SNAP) for treatment of high strength ammonia wastewater. Bioresour Technol. 2014;169:652–7. pmid:25105271
- 22. Tipaldi CF, Vitols K, Kokis T, Trausa A, Sarakovskis A. Experimental and theoretical comparison and analysis of surface-enhanced raman scattering substrates with different morphologies. Appl. Sci. 2024;14(19):9040.
- 23. Sallis PJ, Uyanik S. Granule development in a split-feed anaerobic baffled reactor. Bioresour Technol. 2003;89(3):255–65. pmid:12798116
- 24. Baloch MI, Akunna JC, Kierans M, Collier PJ. Structural analysis of anaerobic granules in a phase separated reactor by electron microscopy. Bioresour Technol. 2008;99(5):922–9. pmid:17531476
- 25. Lei L, Yao J, Liu Y, Li W. Performance, sludge characteristics and microbial community in a salt-tolerant aerobic granular SBR by seeding anaerobic granular sludge. Int Biodeter Biodegrad. 2021;163:105258.
- 26. Lagum AA, Elektorowicz M. Modification of nitrifying microbial community via DC electrical field application. J Environ Chem Eng. 2022;10(3):107743.
- 27. Guo H, Felz S, Lin Y, van Lier JB, de Kreuk M. Structural extracellular polymeric substances determine the difference in digestibility between waste activated sludge and aerobic granules. Water Res. 2020;181:115924. pmid:32492593
- 28. Castellano-Hinojosa A, Armato C, Pozo C, González-Martínez A, González-López J. New concepts in anaerobic digestion processes: recent advances and biological aspects. Appl Microbiol Biotechnol. 2018;102(12):5065–76. pmid:29713791
- 29. Coats ER, Appel FJ, Guho N, Brinkman CK, Mellin J. Interrogating the performance and microbial ecology of an enhanced biological phosphorus removal/post-anoxic denitrification process at bench and pilot scales. Water Environ Res. 2023;95(4):e10852. pmid:36987547
- 30. Wang C, Liu C, Si X. Study on the choice of wastewater treatment process based on the emergy theory. Processes. 2021;9(9):1648.
- 31. Carlson AL, He H, Yang C, Daigger GT. Comparison of hybrid membrane aerated biofilm reactor (MABR)/suspended growth and conventional biological nutrient removal processes. Water Sci Technol. 2021;83(6):1418–28. pmid:33767047
- 32. Zhang Q, Chen W, Yuan C, Liu H, Liang S, Tan S. A novel pure biofilm system based on aerobic denitrification for nitrate wastewater treatment: exploring the feasibility of high total nitrogen removal under low-carbon condition. Chemical Eng J. 2024;480:147978.
- 33. Baeza JA, Gabriel D, Lafuente J. Effect of internal recycle on the nitrogen removal efficiency of an anaerobic/anoxic/oxic (A2/O) wastewater treatment plant (WWTP). Process Biochem. 2004;39(11):1615–24.
- 34. Lagum AA. Simultaneous nitrification and denitrification by controlling current density and dissolved oxygen supply in a novel electrically-induced membrane bioreactor. J Environ Manag. 2022;322:116131.
- 35. Liu S, Chen Y, Xiao L. Metagenomic insights into mixotrophic denitrification facilitated nitrogen removal in a full-scale A2/O wastewater treatment plant. PLoS One. 2021;16(4):e0250283. pmid:33857258
- 36. Wang F, Yang K, Jiang W, Zhao T, Liu W, Yao X, et al. Factors affecting the enrichment of heterotrophic nitrifying aerobic denitrifying bacteria in municipal wastewater treatment systems and analysis of differences in nitrogen metabolism. J Water Proc Eng. 2024;58:104807.
- 37. Adam Lagum A, Al-Ghriybah M, Al-Ma’abreh AM. Coupling membrane electro-bioreactor with anammox process to treat wastewater at low temperatures. Arab J Chemi. 2023;16(10):105165.
- 38. Masoudi SMA, Hedayati Moghaddam A, Sargolzaei J, Darroudi A, Zeynali V. Investigation and optimization of the SND–SBR system for organic matter and ammonium nitrogen removal using the central composite design. Env Prog and Sustain Energy. 2017;37(5):1638–46.
- 39. Chang EE, Chiang PC, Ko YW, Lan WH. Characteristics of organic precursors and their relationship with disinfection by-products. Chemosphere. 2001;44(5):1231–6. pmid:11513412
- 40. Pai T-Y. Modeling nitrite and nitrate variations in A2O process under different return oxic mixed liquid using an extended model. Proc Biochem. 2007;42(6):978–87.
- 41. Crocetti GR, Banfield JF, Keller J, Bond PL, Blackall LL. Glycogen-accumulating organisms in laboratory-scale and full-scale wastewater treatment processes. Microbiology (Reading). 2002;148(Pt 11):3353–64. pmid:12427927
- 42. Wang X, Zhao J, Yu D, Chen G, Du S, Zhen J, et al. Stable nitrite accumulation and phosphorous removal from nitrate and municipal wastewaters in a combined process of endogenous partial denitrification and denitrifying phosphorus removal (EPDPR). Chem Eng J. 2019;355:560–71.
- 43. Zhao W, Huang Y, Wang M, Pan C, Li X, Peng Y, et al. Corrigendum to “Post-endogenous denitrification and phosphorus removal in an alternating anaerobic/oxic/anoxic (AOA) system treating low carbon/nitrogen (C/N) domestic wastewater” [Chem. Eng. J. 339 (2018) 450–458]. Chem Eng J. 2020;394:124812.
- 44. Wong M-T, Mino T, Seviour RJ, Onuki M, Liu W-T. In situ identification and characterization of the microbial community structure of full-scale enhanced biological phosphorous removal plants in Japan. Water Res. 2005;39(13):2901–14. pmid:15993461