Figures
The correct email address for the corresponding author, Cassandra Kraaijenbrink, is: c.kraaijenbrink@umcg.nl.
In the Results subsection of the Abstract, there are errors in the gross mechanical efficiency (ME) values. The correct text is: With a decrease in cadence a slight increase in ME (70 rpm: 8.1 (0.3)%, 60 rpm: 8.5 (0.3)%, 52 rpm: 8.7 (0.2)%, P<0.001, η2p = 0.60), while an increase in FEF (70 rpm: 58.0 (3.2)%, 60 rpm: 66.0 (2.8)%, 52 rpm: 71.3 (2.3)%, P<0.001, η2p = 0.79) is seen simultaneously. Also with an increase in resistance an increase in ME (+0 W: 6.2 (0.3)%, +10 W: 8.8 (0.3)%, +20 W: 10.3 (0.3)%, P<0.001, η2p = 0.92) and FEF (+0 W: 59.0 (2.9)%, +10 W: 66.1 (3.4)%, +20 W: 70.2 (2.4)%, P<0.001, η2p = 0.56) was found.
In the “Effects of cadence and resistance on gross mechanical efficiency” subsection of the Results section, the following sentence is added after recalculating the gross mechanical efficiency: ME increased significantly with a decrease in cadence (η2p = 0.60) and an increase in resistance (η2p = 0.92). This implies that in Fig 3, the values of the mechanical efficiency are incorrect. Please see the correct Fig 3 here.
The mean value and the standard deviation (n = 11) are given for all nine conditions. Significant results following post-hoc pairwise comparisons (Bonferroni corrected): **: P<0.01; ***: P<0.001.
In the Limitations section, there is an error, and an important point is missing after the first sentence.
The correct Limitations are as follows: The participants were all able-bodied to ensure an equal experience level among the subjects and to ensure no preferred handcycle settings were present. Firstly, we found high values of RER (0.93 (0.07)) in every session. Previous research with bicycle ergometers showed that trained individuals had a lower RER than untrained individuals [29,30]. All our participants can be assumed to be untrained in this specific exercise, since they all had no handcycle experience before participating. This could be part of an explanation for the high RER in this exercise type.
Secondly, the users of an add-on handcycle are wheelchair dependent and may differ from an able-bodied population. Nevertheless, the results of the current study are believed to be transferable to this group, since all conditions were sub-maximal and did not require maximal effort. Even though the absolute values of ME may be different for wheelchair users due to different physiological responses, a similar effect of cadence and resistance is expected, an increase in ME with a decrease in cadence and increase in resistance. The same is expected for FEF, even though the total amount of force that can be produced may be less, the effect may still be similar. To get certainty, the experiment should be repeated with wheelchair users.
Lastly, The S1 Dataset is incorrect. Please view the correct S1 Dataset below.
Supporting information
S1 Dataset.
Table 1: data set used for statistical analysis. Table 2: counterbalanced order of the measurements.
https://doi.org/10.1371/journal.pone.0310506.s001
(XLSX)
Reference
- 1. Kraaijenbrink C, Vegter RJK, Hensen AHR, Wagner H, van der Woude LHV (2017) Different cadences and resistances in sub-maximal synchronous handcycling in able-bodied men: Effects on efficiency and force application. PLOS ONE 12(8): e0183502. https://doi.org/10.1371/journal.pone.0183502 pmid:28841704
Citation: Kraaijenbrink C, Vegter RJK, Hensen AHR, Wagner H, van der Woude LHV (2024) Correction: Different cadences and resistances in sub-maximal synchronous handcycling in able-bodied men: Effects on efficiency and force application. PLoS ONE 19(9): e0310506. https://doi.org/10.1371/journal.pone.0310506
Published: September 12, 2024
Copyright: © 2024 Kraaijenbrink et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.