The dynamic response of human lungs due to underwater shock wave exposure

  • Eyal Bar-Kochba ,

    Roles Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Visualization, Writing – original draft

    eyal.bar-kochba@jhuapl.edu

    Affiliation Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, United States of America

  • Alexander S. Iwaskiw,

    Roles Investigation

    Affiliation Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, United States of America

  • Jenna M. Dunn,

    Roles Data curation, Writing – review & editing

    Affiliation Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, United States of America

  • Kyle A. Ott,

    Roles Writing – review & editing

    Affiliation Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, United States of America

  • Timothy P. Harrigan,

    Roles Conceptualization, Methodology, Writing – review & editing

    ¤ Current address: Verisk Extreme Event Solutions, Boston, MD, United States of America

    Affiliation Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, United States of America

  • Constantine K. Demetropoulos

    Roles Conceptualization, Methodology, Writing – review & editing

    Affiliation Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, United States of America

Abstract

Since the 19th century, underwater explosions have posed a significant threat to service members. While there have been attempts to establish injury criteria for the most vulnerable organs, namely the lungs, existing criteria are highly variable due to insufficient human data and the corresponding inability to understand the underlying injury mechanisms. This study presents an experimental characterization of isolated human lung dynamics during simulated exposure to underwater shock waves. We found that the large acoustic impedance at the surface of the lung severely attenuated transmission of the shock wave into the lungs. However, the shock wave initiated large bulk pressure-volume cycles that are distinct from the response of the solid organs under similar loading. These pressure-volume cycles are due to compression of the contained gas, which we modeled with the Rayleigh-Plesset equation. The extent of these lung dynamics was dependent on physical confinement, which in real underwater blast conditions is influenced by factors such as rib cage properties and donned equipment. Findings demonstrate a potential causal mechanism for implosion injuries, which has significant implications for the understanding of primary blast lung injury due to underwater blast exposures.

Introduction

Since the early days of naval warfare in the 19th century, underwater explosions have been responsible for serious injury or even death [1, 2]. Underwater explosive devices such as mines, torpedoes, and depth charges were increasingly common in the early 20th century [3]. In World War II alone, over 1,500 casualties related to underwater blast were documented [4]. While there have been fewer documented cases of injuries due to underwater blasts in recent decades [5], naval warfare has become one of the major emerging battlespaces of the future [6]. As a result, injury or death to service members exposed to underwater blasts has the potential to be more prevalent in the future.

While extensive work has been undertaken to investigate safe and lethal exposure levels under primary blast exposure in air [710], the translation of these limits to underwater blast injury risk is challenging due to fundamental differences in shock wave characteristics between water and air. Shock waves propagate farther and faster in water due to the higher density of water and the corresponding increased speed of sound. When these shock waves reflect off the water surface or ocean floor, they can produce either constructive or destructive interference [11]. Furthermore, the underwater detonation can cause gas bubble cavitation, which generates additional shock waves [11]. Due to the similar densities between humans and water, underwater shock waves are able to transmit more energy to the organs, posing a greater risk to humans [12, 13]. Conversely, the human body reflects more energy from shock waves in air [12].

Gas-containing organs are most vulnerable to underwater primary blast injury [14] due to the sudden decrease in material density and sound speed at the gas-tissue interface, which results in increased shock wave energy deposition [12]. Trauma to the lungs is particularly lethal [1517], as it can result in pulmonary hemorrhage and contusions, gas embolisms, and pneumothorax, among others conditions [16, 18, 19]. Mechanisms of underwater blasts injuries are thought to closely resemble those suggested for air blasts [20], i.e., spallation, implosion, and inertia [16, 21, 22]. However, these mechanisms are poorly understood due to the lack of experimental evidence.

Historically, underwater blast injury studies have sought to establish exposure guidelines for the lungs [13, 20]. Data that inform these guidelines are based on air blast, unscaled animal models, computational models, medical case reports, clinical experience, or even, speculation [13, 20]. The broad range of methods has led to highly inconsistent guidelines, without a consensus exposure metric (e.g., peak pressure or impulse, or charge weight and range). Most importantly, these guidelines are not founded on well-characterized experimental data for humans, which is critical for the establishment of relevant and precise injury guidelines. Until a robust mapping between underwater explosions and human injury is established, military missions will continue to expose service members to underwater blast with an unknown risk of injury or death.

To address the critical need for high-fidelity human lung data, a series of shock tube experiments were conducted where isolated human lungs were exposed to underwater shock waves in a water chamber. The pressure and volumetric response were measured with a combination of pressure sensors and high-speed video, and compared to equivalent measurements from solid organs, i.e., the liver and spleen. Finally, an analytical model based on the Rayleigh-Plesset equation was utilized to further explain the mechanisms that lead to the observed pressure-volume changes and to inform future injury risk metrics.

Materials and methods

Shock tube setup

A shock tube, designed to simulate blast loading pressure profiles, generated short duration underwater overpressure waves to expose submerged organs (Fig 1). The shock tube was divided into four sections; the driver, driven, diffuser, and water chamber (Fig 1A). The driver and driven section are separated by a diaphragm that prevents the flow of pressurized helium from the driver to the driven section. The diaphragm ruptures once a threshold pressure is reached, which produces a shock wave as the pressure wave travels along the driven section. Pressures were measured by a PCB sensor (PCB113B21, PCB Piezotronics, Depew NY). The diaphragm condition was calibrated to deliver repeatable rupture pressures. The pressure wave is then radially expanded from 0.15 m to 0.43 m in diameter by an air-filled conical diffuser as it travels towards the water filled chamber. The diffuser and water-filled chamber are separated by a rubber diaphragm that ensures that water does not enter into the driven section, but still allows for transmission of the shock wave into the water chamber. Tests were run at two burst pressures of 350 kPa and 700 kPa for the liver and the spleen, and 350 kPa and 525 kPa for the lung. There was a discrepancy of the higher burst pressure between the liver and spleen, and lung due to manufacturing and storage differences of the diaphragm materials. Three repeat tests were conducted run at each burst pressure for each specimen.

thumbnail
Fig 1. Experimental setup and organ preparation method for applying overpressure to organs within a water-filled chamber.

(A) Schematic illustrating the key components of the shock tube, including pressure sensors (red downward-point triangles) for measuring the pressure evolution of the shock wave in the driver and driven section, and pressure sensors (magenta downward-pointing triangles) for measuring the overpressure applied to the organ in the water chamber. Lateral images shows the lateral placement (green triangle) and outline (yellow dotted line) of the (B) liver and spleen, and (C) lung within the water chamber. Scale bar, 0.1 m. To prepare the organs for testing, the (D) liver and (E) spleen are encapsulated in a gelatin puck and instrumented with six pressure sensors (blue circle) inserted into the parenchyma and two reference pressure sensors inserted into the gelatin. (F) The right and left lungs were encapsulated in a polyethylene bag installed with a lung insufflation port, a suction port for removing air leakage from the lung, and two sensor ports that pass-through eight pressure sensors (blue circle), with six located under the visceral pleura, one inserted into the main bronchus, and one positioned in the water chamber as a reference measurement.

https://doi.org/10.1371/journal.pone.0303325.g001

The burst pressure was measured by a Kulite pressure sensor (HKS-37, Kulite Semiconductors, Leonia, NJ), installed through the wall of the driver section. The dynamics of shock wave pressure as it propagates along the driven section was measured by an additional five Kulite pressure sensors placed at predetermined intervals. The pressure in the water chamber was measured by five piezoelectric PCB pressure sensors (PCB113B21, PCB Piezotronics, Depew NY), installed through the wall of the water chamber. All pressure data was collected at 1 MHz using a 16-bit high speed data acquisition system (DEWE 801; Dewetron, Wakefield, RI). Pressure values are relative to atmospheric pressure. Lateral images of the dynamic events during shock wave propagation in the water chamber were recorded by a high-speed camera (v711, Phantom, Wayne, NJ) at 2,000 fps. The last test series for the lung had an additional rear facing high-speed camera, which was used to compute the dynamic volume change due to the shock wave. This test series was of right lung specimen tested at both 350 kPa and 525 kPa burst pressures.

Specimen preparation

Tests were performed on the liver (N = 4), spleen (N = 4), left lung (N = 2), and right lung (N = 2) of 6 human cadaver specimens with ages ranging from 61 to 78 years, which were obtained through Science Care (Phoenix, AZ). The study was approved by the U.S. Army Medical Research and Material Command (USAMRMC), Human Research Protections Office for compliance with the USAMRMC Policy for Ethical Use of Human Cadavers in USAMRMC Research and U.S. Army Policy for Use of Human Cadavers for Research, Development, Test, and Evaluation, Education, and Training. Written informed consent was obtained from the donor or next of kin. All donors were screened to avoid any medical issues that would affect the mechanical properties of the tissue, e.g., cancer and chronic obstructive pulmonary disease. Specimens were fresh-frozen at -20°C and stored until testing, which occurred between December 16, 2014 through October 9, 2015. Prior to preparation, specimens were thawed for at least 8 hours at 4°C. The solid organs, the liver and spleen, were encapsulated in a gelatin puck (Fig 1D and 1E). Gelatin was chosen to correspond with the shock impedance properties of soft tissue [2325] and water [26]. A 10% w/v gelatin puck was created from 250 Bloom A Gelatin powder (Knox, Sioux City, IA) according to the protocol outlined by Fackler and Malinowski [27]. Gelatin powder was rigorously mixed into cold water at 7—10°C and subsequently heated until the gelatin was completely dissolved. The gelatin solution, totaling 12 L, was then poured into a cylindrical mold with the same diameter as the water chamber and allowed to cure for at least 8 hours at 4°C. Subsequently, the organ was placed into a cavity in the shape of the organ, which was cut from the surface of the gelatin. An additional 12 L of gelatin solution was poured into the mold to encapsulate the rest of the organ. The gelatin supported the organs to approximate physiological geometry for the duration of the experiment. The final dimensions of the gelatin puck were 0.41 m in depth and 0.43 m in diameter. To measure the dynamic pressure due to the pressure wave in the water chamber, six fiber optic pressure (FOP) sensors (FOP-M-PK, FISO, Quebec, QC, Canada) were inserted into the parenchyma of the liver and spleen through a hollow insertion tube. Two additional FOP sensors were placed into the gelatin to serve as references for computing the incident pressure. The location of the FOP sensors for the liver and spleen are shown in Fig 1D and 1E. A similar procedure was initially repeated for the lungs. However, air leakage during potting and testing compromised the mechanical integrity of the gelatin. Additionally, it was not possible to confirm the insufflation of the lungs during testing since the cured gelatin is opaque.

To overcome these issues with air leakage, a novel encapsulation method for underwater testing of the lungs was developed. The lung was inserted into a polyethylene bag with four liquid-proof ports installed. Two ports served for insufflation and vacuum, and two ports served to insert sensors (Fig 1F). The lung was insufflated during testing by a pump that delivered air at pressures ranging from 5—10 kPa through a vinyl tube that passed through the insufflation port and connected to a barbed polyethylene fitting sutured to the bronchus. These insufflation pressure ranges were based on typical mechanical ventilation pressures [28]. The vacuum port was attached to a pump with a vinyl tube and evacuated the air leaking out of the lungs during testing. To measure the dynamic pressure response of the lung, seven FOP sensors were inserted under the visceral pleura, and one FOP sensor was inserted into the main bronchus. An additional reference pressure sensor was placed next to the lung in the water chamber. This encapsulation method provided three key advantages: 1) precise control of lung insufflation, 2) removal of air leaking from the lung to the water chamber, and 3) full visibility of the lung, allowing the capture of high-speed video.

Prior to testing, organs were placed into the chamber with no water and positioned along the radial center of the chamber and approximately 0.25—0.30 m from the end of the diffuser. To position the lungs for testing, a thin plastic net was anchored to the chamber walls. The sensor cables and tubing for the lung were passed through water-tight ports at the top of the water chamber and the chamber was subsequently filled with water until no air was present. Photos of the nominal pretest position of the liver, spleen, and lungs are shown in Fig 1B and 1C.

Data processing and analysis

Pressure measurements.

Data was processed and analyzed using MATLAB 2022b (Mathworks, Natick, MA). All pressure measurements except those made by the reference pressure sensor next to the organ were filtered with a zero-phase 4-pole Butterworth low-pass filter with a cutoff frequency of 50 kHz. Peak organ pressure was determined by computing the local maxima within 30 ms of the trigger and subsequently verified through visual inspection of the data trace. The dominant frequency of the pressure response of the organ was computed by averaging Welch’s power spectral density [29] across all pressure sensors and subsequently selecting the frequency with the highest power.

To quantify the pressure dose to the organ, incident pressure was computed by subtracting the reference pressure measurement from the chamber pressure measurement closest to the diaphragm. Prior to subtraction, the reference pressure measurement was low-pass filtered with a zero-phase 4-pole Butterworth with a cutoff frequency of 1 kHz to preserve the transient response of the incident pressure wave. This method of computing the incident pressure was chosen in order to overcome limitations associated with pressure measurements collected in an enclosed rigid chamber, where the pressure response of the organ alters the measured chamber pressure due to the relative incompressibility of the water. The subtraction procedure isolates the transient pressure dose from the organ pressure response. S1 Fig shows an example of pressure waveforms of the incident pressure computed using this method.

A two-sided hypothesis test was performed to examine the linear association between the peak pressure and incident pressure, with a significance level of p < 0.05 based on the computed t-statistic of the slope term.

A Shapiro-Wilk test was performed to assess the normality of both the peak pressure range and the dominant frequency. To identify significant pairwise differences across organs, a Kruskal-Wallis test followed by a post-hoc Dunn-Sidak test was conducted, with a significance level set at p < 0.05.

Lung volume measurements.

The volume of the lung (V) for the last test series was computed from the high-speed video by approximating the lung for a single test as an ellipsoid. The equation for the lung volume and corresponding volumetric strain εV relative to the initial volume V0 is given by (1) and (2) respectively, where A is the cross-sectional area of the lung computed by manually tracing the lung boundary from the lateral high-speed video and b is the distance corresponding to the minor axis of an ellipse that was manually fitted to the lung boundary from the rear high-speed video. Manual tracing was repeated every 3 ms for a total of 99 ms post diaphragm burst. The other test series for the lungs were not included in the volumetric analysis since they did not include high speed video of the chamber from the rear view. The volumetric strain rate was computed with forward finite difference.

Analytical modeling of the lung dynamics.

A modified version of the Rayleigh-Plesset (RP) equation [30, 31] was applied to understand the first-order dynamic response of the lungs due to a transient pressure wave [32, 33]. For this model, the lungs are assumed as a spherical gas bubble suspended in a spherical domain of incompressible liquid, which is confined by an elastic spherical shell. The choice of the gas bubble confinement was made to get a preliminary understanding of the confinement effects of the rib cage in humans. The following assumptions are made: (1) the shell inertia are negligible; (2) the gas bubble behavior follows a polytropic process and its pressure is uniform; (3) there is zero mass transport across the bubble interface; and (4) the dynamic viscosity and surface tension effects are negligible due the large dimensions of the bubble (i.e., > 10−1 m) [34]. The equation of motion for the bubble is given by (3) where ρ is the liquid density, p is the pressure inside the bubble, p is the pressure of the liquid, R is the bubble radius with time derivatives and , and λ is a dimensionless parameter defined as the ratio of R to the radius of the spherical shell RS (i.e., λ = R/RS). The last three terms that contain λ are the modification to the classic RP equation, which can be obtained by setting RS = ∞. Due to the liquid incompressibility, RS is related to R via volume conservation by (4) where and R0 are the initial shell radius and bubble radius, respectively. While other versions of the RP equation [35, 36] that can better generalize to other boundary conditions, this version of the confined RP was chosen due to the inclusion of key parameters without undue complexity. Other models of the lungs that account for structure, material properties, and geometry [3639] were considered, but complexity beyond the needs of this study placed these models out of scope.

Eq (3) was numerically solved with MATLAB “ode45” for p and R as a function of time, t, given an incident pressure p, defined as an instantaneous pressure increase with amplitude pA from initial pressure p0 with duration τ, i.e., (5) The volumetric strain was computed with Eq (2), but assuming the volume of a sphere, i.e., V = 4/3πR3.

The parameters for the model were chosen to best match the experimental data. The initial gas bubble radius R0 was set to 0.092 m based on the average effective radius of lung prior to shock wave arrival as computed from the volume estimated with Eq (1). The effective polytropic index for the lung was set to 1.0 based on Wodicka et al. [40]. The liquid density ρ was set to that of water, i.e., 997 kg/m3. Similar to the experimental data, all pressures are relative to atmospheric pressure. Simulations with volumetric strains of less than -95% were not included in the results since this would indicate total bubble collapse, which would lead to very high and unrealistic bubble pressures.

Results

Organ pressure response waveform

A representative pressure response measured by sensors embedded throughout the organ in various locations, along with the corresponding incident pressure waveform is shown in Fig 2. The average peak incident pressure was 68 kPa, 86 kPa, and 113 kPa resulting in a peak organ pressure of 88 kPa, 106 kPa, and 119 kPa for the lung, liver, and spleen, respectively. The pressure response of the lung shows large regional differences in the pressure magnitude (Fig 2A). In contrast, the pressure response of the liver and spleen (Fig 2B and 2C) are tightly grouped, indicating minimal regional differences in pressure magnitude. For all of the organs, the intra-organ pressure responses were in phase, indicating that there was sufficient spatial sampling of the pressure to characterize the bulk pressure response of the organ. The oscillatory behavior was markedly higher for the liver and spleen compared to the lung. The morphology of lung pressure was markedly different, in which the positive pressure peaks were shorter and greater in magnitude compared to the longer negative pressure troughs. The insets in Fig 2 provide a more detailed version of the organ pressure and incident pressure waveforms, and reveals that the liver and spleen exhibit a considerably fast, approximately 2 ms, pressure rise time, compared to the lung with a rise time of approximately 10 ms. Additionally, it is evident from the insets that the incident waveform is characterized by a sub-millisecond rise time and pressure oscillations. These high-frequency pressure oscillations may arise from the pressure wave reflecting off of the chamber walls, which should have an lower bound of 1 kHz based on the time it would take a pressure wave to travel between the front and back of the chamber.

thumbnail
Fig 2. Representative organ pressure response waveforms.

(A) lung, (B) liver, and (C) spleen pressure response due to incident pressure (black line), The light blue line shows the individual organ sensor measurements, while the blue line represents the temporally averaged response. Inset shows the first 5 ms of the organ pressure responses and incident pressure.

https://doi.org/10.1371/journal.pone.0303325.g002

Features of the organ pressure response

The relationship between peak incident pressure, and the intra-organ mean and maximum peak organ pressure is shown in Fig 3A and 3B. The mean peak lung pressures due to incident peak pressures of 53 kPa—108 kPa ranged between 55 kPa—147 kPa, but was not significantly correlated to peak incident pressure (R2 = 0.16, p = 0.06). Conversely, the liver and spleen exhibited a wider range of mean peak organ pressures from 79 kPa to 190 kPa, due to greater burst pressures, which produced a greater down-stream incident pressures from 46 kPa to 177 kPa compared to the lung. A significant positive correlation was observed between peak incident pressure and mean peak organ pressure for the liver (R2 = 0.81, p < 0.001) and spleen (R2 = 0.75, p < 0.001). Maximum peak lung pressures were considerably higher than mean peak lung pressures, and ranged from 68 kPa to 394 kPa, but no significant correlations were observed (R2 = 0.16, p = 0.06). The maximum peak pressure of the liver and the spleen were similar to mean peak pressure and ranged from 83 kPa to 252 kPa. Similar trends across organs were observed with incident impulse, which ranged from 28 to 196 N⋅ms, likely due to correlation between the peak incident pressure and the associated impulse [20]. Maximum peak organ pressure significantly correlated with the peak incident pressure for the liver (R2 = 0.80, p < 0.001) and spleen (R2 = 0.75, p < 0.001). These differences between mean and maximum peak organ pressure were also be observed by computing the regional range of the peak organ pressure on a per test basis (Fig 3C). The lung exhibited a significantly higher peak organ pressure range (median = 103 kPa) than either the liver (median = 19 kPa, p< 0.001) or the spleen (median = 22 kPa, p < 0.001) (Fig 3C). No significant differences were observed between pressure ranges for the liver and spleen (p = 0.82). The lung exhibited a significantly lower dominant frequency response (median = 28 Hz) compared to the liver (median = 176 Hz, p < 0.001) and the spleen (median = 198 Hz, p < 0.001) (Fig 3D). The dominant frequency between the liver and the spleen were significantly different (p < 0.001).

thumbnail
Fig 3. Organ-specific pressure response characterization.

(A) Mean and (B) maximum peak pressure response of lung (blue circle), liver (red square), and spleen (green triangle) with corresponding line of best fit (blue, red, and green dashed lines, respectively) as a function of peak incident pressure. Box-and whiskers plots of the (C) peak pressure range and (D) dominant frequency of the pressure response for liver (n = 20, N = 4), spleen (n = 24, N = 4), and lungs (n = 23, N = 4) showing the median (black line), mean (plus), and interquartile range (gray box). Outliers (circle) are 1.5 times the interquartile range either above or below the non-outlier maximum or minimum shown as whiskers. ***p < 0.001.

https://doi.org/10.1371/journal.pone.0303325.g003

Volumetric response of the lung

The lung underwent large volumetric strains and strain rates due to the pressure wave in the water-filled chamber compared to the liver and spleen (Fig 4). The minimum and maximum volumetric strain for the specimen shown in Fig 2A was -24.0% and 15.6%, respectively (Fig 4A). The maximum and minimum volumetric strain rate was 43.3 s−1 and -41.7 s−1, respectively (Fig 4B). The volumetric strain oscillations occurred at the same dominant frequency as the pressure oscillations shown in Fig 2A. The corresponding lateral high-speed images of the lung in the undeformed, most compressed, and most expanded state of the lung are shown in Fig 4C and 4D. In the most compressed state, the lung surface deformed non-uniformly. S1 Video shows the temporal evolution of the volumetric response at 0.2 ms intervals.

thumbnail
Fig 4. Volumetric deformation of the lung due to shockwave exposure.

(A) Volumetric strain and (B) strain rate time series of the lung with six tests (gray) and corresponding mean (black). Outlines of the lung are shown in the undeformed at 0 ms (red), most compressed at 10 ms (yellow), and most expanded at 25 ms (blue) state. (C) Lateral image in the undeformed state with an overlay of the lung outlines shown in (A). (D) Enlarged images of the lung shown in (C). Scale bar, 0.1 m.

https://doi.org/10.1371/journal.pone.0303325.g004

Analytical model of the lung pressure-volume response

A confined Rayleigh-Plesset (RP) equation was solved to understand the driving force behind the pressure-volume response of the lung due to a transient pressure pulse. For this model, the lungs are assumed to be a spherical gas bubble with initial radius R0 suspended in a spherical domain of incompressible liquid confined by a spherical shell with radius RS. Fig 5 shows solutions for the bubble pressure (p) and volumetric strain εV for a range of different incident pressures amplitudes (pA) and durations (τ), and for different bubble confinement (denoted as the ratio of RS to R0). The waveform morphology of bubble pressure exhibited shorter duration positive pressure peaks with larger magnitudes compared to the longer negative pressure troughs, which were more pronounced with higher incident pressures (Fig 5A). The corresponding volumetric strain of the bubble was inversely related to the bubble pressure due to the gas behavior following a polytropic process. The maximum bubble pressure and volumetric strain scaled nonlinearly with both the incident pressure amplitude and duration (Fig 5B and 5C) and impulse (S2 Fig). Across the simulated pressure durations (τ), p was less pA. However, for τ = 10 ms, simulations with pA above approximately 130 kPa, yielded volumetric strains greater then 95%, leading to near bubble collapse and very high bubble pressures. As a result, these data were not included in (Fig 5B and 5C). As the bubble becomes more confined (i.e., RS/R0 → 1.1), the maximum bubble pressures and volumetric strains increased by 3.3 to 8.3 times and 3.3 to 3.4 times, respectively (Fig 5D).

thumbnail
Fig 5. Analytical solution of the modified Rayleigh-Plesset equation of a spherical gas bubble with initial radius R0 within a spherical water chamber of radius RS.

(A) Bubble pressure, (p; blue) and volumetric strain (εV; red) waveforms due to a square pressure pulse with amplitudes pA = 100 kPa (dotted), 200 kPa (dashed), and 400 kPa (solid) and duration τ = 10−3 s within an infinitely large water chamber, i.e., RS/R0 = ∞. Maximum (B) p and (C) εV for increasing values of pA and τ = 10−4 s (solid), 10−3 s (dashed), and 10−2 s (dotted) at RS/R0 = ∞. Maximum (D) p and (E) εV for increasing values of pA and RS/R0 = 1.1 (solid), 2.0 (dashed), and ∞ (dotted) at τ = 10−3 s.

https://doi.org/10.1371/journal.pone.0303325.g005

Discussion

While there been many attempts to establish injury guidelines for the human lungs exposed to underwater blast [13, 20], the criteria remain highly variable due to a lack of sufficient human data to reveal the underlying injury mechanisms. To address this gap, a series of shock tube experiments that subjected isolated lungs to shock waves in a water chamber were conducted. Experiments were repeated with the liver and the spleen to compare lung response to those of solid organs. Lastly, this study utilized an analytical model based on the Rayleigh-Plesset (RP) equation to isolate the effect of air on lung response and to understand the mechanisms of lung deformation.

Upon analyzing the pressure measurements (Fig 2A), transient spikes in lung pressure were not observed with a duration similar to the incident pressure waveform, suggesting that shock wave front propagation through the lungs is severely attenuated. This attenuation is likely due to the unique structure of the lung, which is composed of many microscopic air sacs. Each air sac acts as a high acoustic impedance solid-gas interface that diffracts and reflects the shock wave front. At a macro-scale, these events superimpose to severely and quickly dissipate the energy of the shock wave front. This proposed dissipation mechanism is similar to the well-characterized shock wave attenuation mechanisms in foams [41, 42]. Despite substantial shock wave attenuation, the lungs still underwent large pressure cycles characterized by larger magnitudes with shorter positive pressure peaks, and smaller magnitudes with longer negative pressure troughs (Fig 2A) repeating at approximately 28 Hz (Fig 2D). In comparison, the solid organs exhibited a much faster oscillatory response between 175 Hz and 200 Hz, which may correspond to the resonant frequency of these organs. Unlike the solid organs, the peak pressures associated with these cycles exhibited large test-to-test variations that did not correlate with peak incident pressures (Fig 3A and 3B). In some tests, the measured peak pressure greatly exceeded peak incident pressure. This finding provides further evidence that the pressure response is not dominated by the shock wave front.

The pressure cycles in Fig 2A and inversely associated volumetric strains (Fig 4B) are indicative of the thermodynamic processes of gases [43]. To gain insights into this interesting PV behavior, we solved a RP equation where a spherical gas bubble within a domain of incompressible liquid subject to a short-duration pressure square wave [30, 31]. Fetherston et al. solved a similar equation to understand the dynamics of marine mammal lungs when exposed to underwater blast [36]. Although this RP model oversimplifies the complexities of lung composition, material properties, and structure, the PV time series (Fig 5A) exhibits waveform morphologies that are remarkably similar to those of the lung (Figs 2A and 4B). These morphological similarities provide evidence that the bulk PV response of the lung is due to the compression of the contained gas, which is initiated by the shock wave. One possible mechanism for how the shock wave initiates lung compression is that the external water-tissue interface has a small acoustic impedance mismatch, so the reflection from the water-tissue interface is small, allowing more energy to be transmitted into the body. However, at the interface between the pleural cavity and the lung, the acoustic impedance mismatch is large, leading to substantial energy deposition at the lung surface, which then initiates a bulk PV response. This proposed mechanism of lung compression in underwater blast exposure is substantially different from the mechanism of lung compression in air blast exposure as modeled by Stuhmiller [44], due to the difference in the surrounding fluid. In Stuhmiller’s analysis, the air-to-tissue interface reflects the blast wave, resulting in momentum transfer to the outer tissues of the chest and abdomen. Resulting motion of the chest wall and diaphragm are then used to develop a model for lung compression. Another possible mechanism for how the shock wave initiates lung compression can be observed in studies involving foams, where heavily attenuated shock waves convert to high-pressure compression waves causing foam compaction [45]. For both initiation mechanisms, we expect that these PV cycles are also present when the lung is exposed to air blast, but with smaller amplitudes due to weaker acoustic coupling between the torso and the air compared to coupling with water [12, 13], and higher frequencies due to air having less inertia than the surrounding water.

Confinement on the lungs by the rib cage plays a critical role in PV response. To understand these effects, a solution to the modified version of the RP equation that accounts for confinement was solved by enclosing the gas bubble and surrounding liquid with an elastic shell [32, 33]. By accounting for confinement, bubble pressures substantially increased by up to approximately 8 times when the bubble was in a shell that is 10% larger than its original radius (Fig 5D). Although we expect the corresponding volumetric strain in real scenarios to decrease with confinement in humans, our model shows the opposite (Fig 5E). This discrepancy is attributed to the treatment of the elastic shell in Eq (4) as variations of bubble volume were accommodated by modifying the shell radius. From an injury perspective, a decreased volumetric strain is desirable. Yet, this accommodation comes at the cost of inducing higher alveolar pressures, which could lead to increased forced air emboli into the capillary [46]. This confinement could also lead to local tissue shearing when the soft lungs expand and impinge on the stiffer rib cage, potentially causing the lung tissue to deform into the intercostal space. This mechanism of injury is consistent with clinical observations of rib markings on the lungs following air blast injury [47]. However, in air blast scenarios, the transfer of momentum to the chest wall due to the high acoustic impedance produces rib motion that would compress the lungs, whereas in the underwater blast scenarios, the lungs would expand into the rib cage. The effects of lung confinement are likely to vary based on the individuals rib cage stiffness and geometry, as well as donned personal protective equipment, or occupation specific equipment, which may further restrict the lungs.

These findings have significant implications for our understanding of the injury mechanisms for lungs and other gas-containing organs exposed to underwater blast. While the the mechanisms of lung injury in underwater blasts are thought to closely follow, albeit be more damaging, those of air blasts [20], i.e., spallation, implosion, and inertia [21], the extent of damage caused by these mechanisms remains unknown despite numerous studies on air blast injuries [16]. Among these mechanisms, implosion forces are the most consistent with the observed lung response in this study, resulting in rapid compression and expansion of gaseous content. At the alveolar length scale, compression can cause the alveolus to collapse and result in atelectasis [48], while pneumothorax can occur at the length scale of the lung [18, 19]. Rapid lung expansion can cause alveolar and capillary overstretching and rupture, or the driving of extravascular fluid into the alveolar space, causing pulmonary oedema and hemorrhage [16]. These injuries may not present uniformly throughout the lung based on regional pressure differences (Figs 2 and 3C) that are due to the heterogeneous structure of the lung. Previously, the implosion mechanism was first postulated by Forbes in 1812 [49], later described by Schardin in 1950 [21], and conceptually modeled by Ho in 2002 [46]. Yet, to the best of our knowledge, this study is the first to present experimental evidence of this mechanism, and with direct visualization of lung volume over the course of events.

Peak incident pressures and associated impulses measured in this study fall within the reported range of previous studies [13, 20]. However, it is difficult to determine the severity of injury that would be obtained in this study with any granularity based on the large spread in the injury criteria [13, 20]. This variability in reported data is likely due to the variety of approaches that have been used to develop these criteria, each with its own significant limitations [13]. The peak incident pressures and impulses measured in this study are most likely above safe levels based on an animal study conducted by Richmond et al. [50, 51], but below 50% lethality based on a study by Lance et al. [20] that combined field injury data with computational predictions of incident pressures and impulses. It is important to note that the injury criteria developed in these studies are based on incident pressure and not the lung pressure, which can reach up to approximately six times the peak incident pressure (Fig 3B). These internal pressures should be an important factor in the development of future injury criteria, as they are a more accurate representation of tissue level loading that directly leads to injury.

Conclusion

This study provides the first directly observable experimental data and characterization of human lung dynamics when exposed to underwater blast. We found that the shock wave front was severely attenuated by the high acoustic impedance gas-solid microstructure of the lung, similar to gas-filled foams [41, 42]. However, the shock wave front initiated large bulk PV cycles that are distinct from the solid organs. By solving the RP equation, we show that these large PV cycles are due to the compression of contained gas, which follows a classic thermodynamic process [43]. By further modifying the RP equation to include physical confinement, we find that the PV cycles are also highly depending on physical confinement, which is dependent on the rib cage properties and may be modified by donned equipment. These findings have significant implications for our understanding of the proposed injury mechanisms both for underwater and air blast exposures, in that they provides the first direct evidence of the implosion injury mechanism, which has was first proposed in 1817 by Forbes [49] and has been expanded on over the course of over two centuries [21, 46].

A number of future studies are needed to fully characterize lung dynamics during blast and their role in injury. In this study, isolated lungs were placed in a chamber that is not fully representative of human blast exposure in an open body of water. The experimental setup involving an organ confined within a chamber presents two major limitations. Firstly, shock wave reflections occur at the chamber walls, resulting in these reflected waves impinging on the organs. Secondly, the PV changes induced in the organs cause measured pressure changes in the chamber, making it challenging to accurately quantify the true incident pressure dose without further data processing. These limitations would be overcome by running tests in substantially larger volume of water that would also recreate open water phenomena, e.g., shockwave reflection from the ocean floor or rarefaction from the surface [13, 20]. Additionally, these shock waves should be generated with underwater explosives to better represent real world exposure to blast, and should cover a larger range of incident pressures to form a basis of comparison with previous injury criteria [20].

Future studies should also characterize the dynamics of the lungs with a combination of experimental models. These studies should include additional cadaveric experiments to ensure a more accurate geometry and structure (e.g., the effects of the rib cage), and animal experiments to better characterize injury in vivo. To fully understand the injury mechanisms on the alveolar length scale, more detailed in vitro and in vivo models are needed in conjunction with higher resolution imaging techniques [52, 53] to overcome the issues with limited pressure sensing resolution.

Higher fidelity computational models of the lungs exposed to underwater blast are critical to understanding the injury mechanisms and designing protective measures. Our study involved the use of the RP equation to create a analytical model of the lung, which is intended to be a first-order approximation for the lung. This model oversimplified the true composition, material properties, and structure of real lungs, resulting in PV responses that were different from the test data. Peak pressures and volumetric strains, as well as their rates of decay, are different than the test data. Specifically, by the third PV cycle, the maximum PV of that cycle has decreased by over 50% (Fig 4A). We believe that these discrepancies are based on the need to explicitly include sources of energy loss. For example, this model does not account for dynamic viscosity of the liquid and bubble surface tension [31], but we believe that these factors are negligible due to the larger dimensions of the bubble [34]. Additionally, the model does not account for the viscoelastic nature of the lung [54, 55] due to the tissue, which would produce lower volumetric strains compared to the RP model since the stiffness of the tissue would resist volumetric strain. This tissue resistance would also affect the subsequent decay of the PV response. Future studies should build on the history of high fidelity finite element models used for blast [39, 44, 5660] to better understand the unique PV response. However, these models must be validated against high-fidelity human data collected in underwater blast scenarios similar to those presented in this study.

Supporting information

S1 Fig. Representative pressure waveforms to illustrate the incident pressure calculation.

The incident pressure (black) was computed by subtracting a filtered reference pressure measurement (red) from the pressure measurement made at the wall closest to the diaphram (green).

https://doi.org/10.1371/journal.pone.0303325.s001

(TIF)

S2 Fig. Bubble dynamics due to incident pressure impulse.

Analytical solution of the Rayleigh-Plesset equation of a spherical gas bubble with initial radius R0 within a unconstrained spherical water chamber of radius RS = ∞. Maximum (A) bubble pressure p and (B) volumetric strain εV for increasing values of pressure impulse for incident pressure durations of τ = 10−4 s (solid), 10−3 s (dashed), and 10−2 s (dotted).

https://doi.org/10.1371/journal.pone.0303325.s002

(TIF)

S1 Video. Lateral high-speed video of the lung undergoing volumetric deformation due to incident pressure.

https://doi.org/10.1371/journal.pone.0303325.s003

(MOV)

S1 File. MATLAB code for generating presented data in manuscript.

https://doi.org/10.1371/journal.pone.0303325.s004

(M)

Acknowledgments

The authors would like to thank Andrew Merkle and Robert Armiger for their management of the overarching project and Catherine Carneal for manuscript review.

References

  1. 1. Green JB. Diving with & Without Armor: Containing the Submarine Exploits of JB Green. Buffalo, NY: Faxon’s Steam Power Press, Buffalo, NY; 1859.
  2. 2. Heinke JW. On the Improvements in Diving Dresses and Other Apparatus for Working Under Water. Royal United Services Institution Journal. 1860;4(12):106–120.
  3. 3. Gordon A. The rules of the game: Jutland and British naval command. Naval Institute Press; 2013.
  4. 4. Williams E. Blast effects in warfare. Journal of British Surgery. 1942;30(117):38–49.
  5. 5. Petri NM, Dujella J, Definis-Gojanovic M, Vranjkovic-Petri L, Cuculic D. Diving-related fatalities caused by underwater explosions: a report of two cases. The American journal of forensic medicine and pathology. 2001;22(4):383–386. pmid:11764906
  6. 6. Mastro OS. Military Confrontation in the South China Sea. Center for Preventive Action. 2020.
  7. 7. Bowen IG, Fletcher ER, Richmond DR. Estimate of man’s tolerance to the direct effects of air blast. Lovelace Foundation for Medical Education and Research, Albuquerque, NM; 1968. AD0693105.
  8. 8. Bass CR, Rafaels KA, Salzar RS. Pulmonary Injury Risk Assessment for Short-Duration Blasts. Journal of Trauma: Injury, Infection & Critical Care. 2008;65(3):604–615. pmid:18784574
  9. 9. Rafaels KA, Bass CR, Panzer MB, Salzar RS. Pulmonary Injury Risk Assessment for Long-Duration Blasts: A Meta-Analysis. Journal of Trauma: Injury, Infection & Critical Care. 2010;69(2):368–374. pmid:20699746
  10. 10. Boutillier J, Deck C, Mezzo SD, Magnan P, Prat N, Willinger R, et al. Lung injury risk assessment during blast exposure. Journal of Biomechanics. 2019;86:210–217. pmid:30808500
  11. 11. Costanzo FA. Underwater explosion phenomena and shock physics. In: Structural Dynamics, Volume 3: Proceedings of the 28th IMAC, A Conference on Structural Dynamics, 2010. Springer; 2010. p. 917–938.
  12. 12. Nguyen N, Hunt JP, Lindfors D, Greiffenstein P. Aerial fireworks can turn deadly underwater: Magnified blast causes severe pulmonary contusion. Injury Extra. 2014;45(4):32–34.
  13. 13. Lance RM, Capehart B, Kadro O, Bass CR. Human Injury Criteria for Underwater Blasts. PLOS ONE. 2015;10(11):e0143485. pmid:26606655
  14. 14. Ritenour AE, Baskin TW. Primary blast injury: Update on diagnosis and treatment. Critical Care Medicine. 2008;36(Suppl):S311–S317. pmid:18594258
  15. 15. Mellor SG. The relationship of blast loading to death and injury from explosion. World Journal of Surgery. 1992;16(5):893–898. pmid:1462626
  16. 16. Wolf SJ, Bebarta VS, Bonnett CJ, Pons PT, Cantrill SV. Blast injuries. The Lancet. 2009;374(9687):405–415. pmid:19631372
  17. 17. Singleton JAG, Gibb IE, Bull AMJ, Mahoney PF, Clasper JC. Primary blast lung injury prevalence and fatal injuries from explosions. Journal of Trauma and Acute Care Surgery. 2013;75(2):S269–S274. pmid:23883919
  18. 18. Stapczynski JS. Blast injuries. Annals of Emergency Medicine. 1982;11(12):687–694. pmid:7149365
  19. 19. Sziklavari Z, Molnar TF. Blast injures to the thorax. Journal of Thoracic Disease. 2019;11(S2):S167–S171. pmid:30906581
  20. 20. Lance RM, Bass CR. Underwater blast injury: a review of standards. Diving Hyperbaric Medicine. 2015;45(3):190–199. pmid:26415071
  21. 21. Schardin H. The physical principles of the effects of a detonation. German Aviation Medicine, World War II. 1950;2:1207–1224.
  22. 22. Li N, Geng C, Hou S, Fan H, Gong Y. Damage-Associated Molecular Patterns and Their Signaling Pathways in Primary Blast Lung Injury: New Research Progress and Future Directions. International Journal of Molecular Sciences. 2020;21(17):6303. pmid:32878118
  23. 23. Shepherd CJ, Appleby-Thomas GJ, Hazell PJ, Allsop DF, Elert M, Furnish MD, et al. The Dynamic Behavior of Ballistic Gelatin. In: AIP Conference Proceedings; 2009.
  24. 24. Cook JR, Bouchard RR, Emelianov SY. Tissue-mimicking phantoms for photoacoustic and ultrasonic imaging. Biomedical Optics Express. 2011;2(11):3193. pmid:22076278
  25. 25. Forbes JW. Impedance Matching Technique. Shock Wave Compression of Condensed Matter: A Primer. 2012; p. 31–57.
  26. 26. Alves N, Kim A, Tan J, Hwang G, Javed T, Neagu B, et al. Cardiac Tissue-Mimicking Ballistic Gel Phantom for Ultrasound Imaging in Clinical and Research Applications. Ultrasound in Medicine & Biology. 2020;46(8):2057–2069. pmid:32430107
  27. 27. Fackler ML, Malinowski JA. The wound profile: a visual method for quantifying gunshot wound components. The Journal of Trauma: Injury, Infection, and Critical Care. 1985;25(6):522–529. pmid:4009751
  28. 28. Wenzel V, Idris AH, Dörges V, Nolan JP, Parr MJ, Gabrielli A, et al. The respiratory system during resuscitation: a review of the history, risk of infection during assisted ventilation, respiratory mechanics, and ventilation strategies for patients with an unprotected airway. Resuscitation. 2001;49(2):123–134. pmid:11382517
  29. 29. Welch P. The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms. IEEE Transactions on Audio and Electroacoustics. 1967;15(2):70–73.
  30. 30. Rayleigh L. VIII. On the pressure developed in a liquid during the collapse of a spherical cavity. The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science. 1917;34(200):94–98.
  31. 31. Plesset MS. The Dynamics of Cavitation Bubbles. Journal of Applied Mechanics. 1949;16(3):277–282.
  32. 32. Fourest T, Laurens JM, Deletombe E, Dupas J, Arrigoni M. Analysis of bubbles dynamics created by Hydrodynamic Ram in confined geometries using the Rayleigh–Plesset equation. International Journal of Impact Engineering. 2014;73:66–74.
  33. 33. Fourest T, Laurens JM, Deletombe E, Dupas J, Arrigoni M. Confined Rayleigh–Plesset equation for Hydrodynamic Ram analysis in thin-walled containers under ballistic impacts. Thin-Walled Structures. 2015;86:67–72.
  34. 34. Chapman RB, Plesset MS. Thermal Effects in the Free Oscillation of Gas Bubbles. Journal of Basic Engineering. 1971;93(3):373–376.
  35. 35. Vincent O, Marmottant P. On the statics and dynamics of fully confined bubbles. Journal of Fluid Mechanics. 2017;827:194–224.
  36. 36. Fetherston T, Turner S, Mitchell G, Guzas E. Marine Mammal Lung Dynamics when Exposed to Underwater Explosion Impulse. The Anatomical Record. 2018;302(5):718–734. pmid:30450793
  37. 37. Chanda A, Callaway C. Computational modeling of blast induced whole-body injury: a review. Journal of Medical Engineering & Technology. 2018;42(2):88–104. pmid:29473767
  38. 38. Herrmann J, Tawhai MH, Kaczka DW. Computational Modeling of Primary Blast Lung Injury: Implications for Ventilator Management. Military Medicine. 2019;184(Supplement_1):273–281. pmid:30901433
  39. 39. Yang C, Dong-hai Z, Ling-ying L, Yong-hui Y, Yang W, Li-wei Z, et al. Simulation of blast lung injury induced by shock waves of five distances based on finite element modeling of a three-dimensional rat. Scientific Reports. 2019;9(1). pmid:30837628
  40. 40. Wodicka GR, Stevens KN, Golub HL, Cravalho EG, Shannon DC. A model of acoustic transmission in the respiratory system. IEEE Transactions on Biomedical Engineering. 1989;36(9):925–934. pmid:2777281
  41. 41. Kitagawa K, Yasuhara M, Takayama K. Attenuation of shock waves propagating in polyurethane foams. Shock Waves. 2006;15(6):437–445.
  42. 42. Kazemi-Kamyab V, Subramaniam K, Andreopoulos Y. Stress transmission in porous materials impacted by shock waves. Journal of Applied Physics. 2011;109(1):013523.
  43. 43. Cengel YA, Boles MA, Kanoğlu M. Thermodynamics: an engineering approach. vol. 5. McGraw-hill New York; 2011.
  44. 44. Stuhmiller JH. Biological response to blast overpressure: A summary of modeling. Toxicology. 1997;121(1):91–103. pmid:9217318
  45. 45. Skews BW, Atkins MD, Seitz MW. The impact of a shock wave on porous compressible foams. Journal of Fluid Mechanics. 1993;253(-1):245.
  46. 46. Ho AMH. A simple conceptual model of primary pulmonary blast injury. Medical Hypotheses. 2002;59(5):611–613. pmid:12376089
  47. 47. Clemedson CJ, Granström SA. Studies on the Genesis of “Rib Markings” in Lung Blast Injury. Acta Physiologica Scandinavica. 1950;21(2-3):131–144. pmid:14856764
  48. 48. Zhang B, Wang A, Hu W, Zhang L, Xiong Y, Chen J, et al. Hemoconcentration Caused by Microvascular Dysfunction After Blast Injuries to the Chest and Abdomen of Rabbits. Journal of Trauma and Acute Care Surgery. 2011;71(3):694–701.
  49. 49. Forbes P. Observations on the Cause of Death from What Is Called the Wind of a Ball. Edinburgh Medical and Surgical Journal. 1812;8(31):310–312. pmid:30329505
  50. 50. Richmond DR, Yelverton JT, Fletcher ER. Far-field underwater-blast injuries produced by small charges. Lovelace Foundation for Medical Education and Research, Albuquerque, NM; 1973. AD0763497.
  51. 51. Richmond D. Underwater shock facility and explosion levels evaluated by a swimmer. In: Proceedings, 5th International Symposium on Military Applications of Blast Simulation; 1977.
  52. 52. Matuszak J, Tabuchi A, Kuebler WM. Ventilation and Perfusion at the Alveolar Level: Insights From Lung Intravital Microscopy. Frontiers in Physiology. 2020;11. pmid:32308629
  53. 53. Arora H, Nila A, Vitharana K, Sherwood JM, Nguyen TT, Karunaratne A, Mohammed IK, et al. Microstructural Consequences of Blast Lung Injury Characterized with Digital Volume Correlation Frontiers in Materials. 2017;4:41.
  54. 54. Birzle AM, Wall WA. A viscoelastic nonlinear compressible material model of lung parenchyma—Experiments and numerical identification. Journal of the Mechanical Behavior of Biomedical Materials. 2019;94:164–175. pmid:30897504
  55. 55. Fung Yc. Biomechanics: mechanical properties of living tissues. Springer Science & Business Media; 2013.
  56. 56. Stuhmiller JH, Chuong CJ, Phillips YY, Dodd KT. Computer modeling of thoracic response to blast. Journal of Trauma and Acute Care Surgery. 1988;28(1):S132–S139. pmid:3339675
  57. 57. Greer A, Cronin D, Salisbury C, Williams K. Finite Element Modeling for the Prediction of Blast Trauma. In: IUTAM Symposium on Impact Biomechanics: From Fundamental Insights to Applications. Springer-Verlag; 2007. p. 263–271.
  58. 58. Ward E, Merkle A, Harrigan T, Roberts J. Comparing blast effects on human torso finite element model against existing lethality curves. Johns Hopkins University Applied Physics Laboratory, Laurel, MD; 2010. ADA532225.
  59. 59. Gibbons MM, Dang X, Adkins M, Powell B, Chan P. Finite Element Modeling of Blast Lung Injury in Sheep. Journal of Biomechanical Engineering. 2015;137(4). pmid:25411822
  60. 60. Zhou J, Tao G. Biomechanical modeling for the response of human thorax to blast waves. Acta Mechanica Sinica. 2015;31(4):589–598.