Diagnostic accuracy of digital technologies compared with 12-lead ECG in the diagnosis of atrial fibrillation in adults: A protocol for a systematic review

Abstract

Background

Atrial fibrillation (AF) is the most prevalent cardiac arrhythmia in the world. AF increases the risk of stroke 5-fold, though the risk can be reduced with appropriate treatment. Therefore, early diagnosis is imperative but remains a global challenge. In low-and middle-income countries (LMICs), a lack of diagnostic equipment and under-resourced healthcare systems generate further barriers. The rapid development of digital technologies that are capable of diagnosing AF remotely and cost-effectively could prove beneficial for LMICs. However, evidence is lacking on what digital technologies exist and how they compare in regards to diagnostic accuracy. We aim to systematically review the diagnostic accuracy of all digital technologies capable of AF diagnosis.

Methods

MEDLINE, Embase and Web of Science will be searched for eligible studies. Free text terms will be combined with corresponding index terms where available and searches will not be limited by language nor time of publication. Cohort or cross-sectional studies comprising adult (≥18 years) participants will be included. Only studies that use a 12-lead ECG as the reference test (comparator) and report outcomes of sensitivity, specificity, the diagnostic odds ratio (DOR) or the positive and negative predictive value (PPV and NPV) will be included (or if they provide sufficient data to calculate these outcomes). Two reviewers will independently assess articles for inclusion, extract data using a piloted tool and assess risk of bias using the QUADAS-2 tool. The feasibility of a meta-analysis will be determined by assessing heterogeneity across the studies, grouped by index device, diagnostic threshold and setting. If a meta-analysis is feasible for any index device, pooled sensitivity and specificity will be calculated using a random effect model and presented in forest plots.

Discussion

The findings of our review will provide a comprehensive synthesis of the diagnostic accuracy of available digital technologies capable for diagnosing AF. Thus, this review will aid in the identification of which devices could be further trialed and implemented, particularly in a LMIC setting, to improve the early diagnosis of AF.

Trial registration

Systematic review registration:

PROSPERO registration number is CRD42021290542. https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42021290542.

Background

Atrial fibrillation (AF) is the most common cardiac arrhythmia in the world with prevalence predicted to double over the next 30 years [1]. The risk of stroke is five-fold in AF patients; however, early anticoagulation therapy can reduce this risk by 65% [2]. Early diagnosis of AF is key for ensuring early effective treatment thus avoiding fatal and debilitating strokes. It is estimated that 15% of people with AF in high-income countries are not diagnosed, of whom up to 75% could be eligible for anticoagulation therapy [3]. In low- and middle-income countries (LMICs), under diagnosis is amplified due to limited resources, lack of knowledge of AF (in primary care and in the public) and cost implications [4,5].

Digital health technologies to improve the accuracy and diagnostic rate of AF have rapidly advanced in the last decade [6,7]. Examples include smart watches, smart belts, single lead mobile based electrocardiogram (ECG), portable Holter monitoring devices, modified blood pressure monitors and photoplethysmography (PPG) [7]. These technological advancements are often minimally-intrusive and enable self-testing and ad-hoc long-term monitoring [6]; thus, improving early diagnosis and self-monitoring by mitigating barriers of inaccessibility to and non-attendance at healthcare facilities. Advanced devices allow for the transfer of physiological parameters and patient-reported symptoms directly from smartphone applications to healthcare providers, reducing the number of healthcare visits necessary; thus, reducing costs on the patient and healthcare system [6,8]. Mobile connectivity has exponentially increased globally over the last 20 years, including in LMICs where now more than half the population use mobile internet [9,10]. As the growth of mobile connectivity continues to rise, the benefits of using digital technologies will become increasingly notable in LMICs where AF burden is increasing the most [11].

Eight systematic reviews were identified on the diagnostic accuracy of digital technologies such PPG, mobile applications, single lead ECGs and smart wearable devices for AF [1220] However, six of these reviews only assessed one type of technology. For instance, Belani et al (2021), Gill S et al (2022) [12,17] Nazarian S (2020) et al and Narut et al (2021) only reviewed the diagnostic accuracy of smart gadgets and wearable devices such smart watches [13,18]; and Wong et al (2020) only reviewed diagnostic accuracy of handheld electrocardiogram [20]; and O’Sullivan JW et al reviewed diagnostic accuracy of smartphone camera applications [16]. Including all types of technologies in one review, with pooled diagnostic accuracy stratified by type of device would be useful in deciding which device to take forward for testing in new settings, particular in resource-limited settings. Giebel et al reviewed the diagnostic accuracy of all types of technologies; however, the inclusion criteria were restricted to publication years 2014 to 2019, they did not restrict to studies that only used a 12-lead ECG (the gold standard) as the comparison device. Using different comparison devices can lead to discrepancies in diagnostic accuracy. Lopez et al also reviewed all types of technologies, but also limited their search to 2012 to 2019 and did not restrict to studies using the gold standard as a comparator device (including several studies where the comparator was not described). Furthermore, several studies that report on the AF diagnostic accuracy of digital technologies have been published since the search was conducted for these two existing systematic reviews. Thus, an updated comprehensive review on the diagnostic accuracy of all digital technologies compared to the gold standard will aid in the selection of which digital device(s) can and should be tested in LMICs. Therefore, we aimed to conduct a systematic review to assess the diagnostic accuracy of digital technologies that can be used for diagnosing AF. To reach this aim, we propose to answer the following questions:

  1. Q1: What digital technologies has available diagnostic accuracy data for AF diagnosis?
  2. Q2: What digital technology is the most accurate for diagnosing AF?

Methods

This protocol has been registered within the International Prospective Register of Systematic Reviews (PROSPERO) database [21] (registration number CRD42021290542) and is reported in line with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis Protocols (PRISMA-P) (S1 File) [22]. The methods of this systematic review is in line with the Cochrane Handbook for Systematic Reviews [23].

Eligibility criteria

Study eligibility will be determined through a pre-defined PICOS criteria (Table 1).

Inclusion criteria.

We will include primary studies that assess AF within an adult participants aged 18 years or older (population) using any mobile application, ECG based digital technology or non-ECG-based digital technology (intervention) compared with a 12-lead ECG (comparator) and reporting on the following outcomes sensitivity and specificity, the diagnostic odds ratio (DOR), negative and positive predictive values (NPV and PPV), or figures that can be used by review authors to calculate these measures: (i.e. true positive (TP), true negative (TN), false positive (FP), false negative (FN). Only cohort and cross-sectional study designs will be deemed eligible.

Mobile applications that will be considered includes but are not limited to Cardiogram application and Cardio Rhythm. ECG based digital technologies that will be considered includes but are not limited to handheld devices, smart watches, single lead ECG (Kardia), wearables (bio-textiles, belt) and patches. Non-ECG based digital technologies that will be considered includes but are not limited to PPG, oscillometry, mechanocardiograph, modified BP meters and contactless video PPG.

Authors will calculate the outcomes of interest from studies that only report true positive and negative values using the following:

  • TP/(TP+FN) = Sensitivity
  • TN/(TN+FP) = Specificity
  • (TP/FN)/(FP/TN) = DOR
  • TN/(TN+FN) = NPV
  • TP/(TP+FP) = PPV

Inclusion criteria.

We will exclude any studies that do not report the outcomes of interest specifically for AF and the following study designs: interventional studies, review articles, editorials, case reports, modelling, economic studies, or clinical trials.

Search strategy

MEDLINE and Embase via OVID will be searched for eligible studies. A search of grey literature will be conducted using Web of Science database. References of all included studies and existing systematic reviews identified from the search will be assessed for additional eligible studies not identified within the search.

Key terms such as “atrial fibrillation”, “mHealth”, “eHealth”, “sensitivity” and “specificity” will be used alongside MeSH and Emtree terms where appropriate. A draft search strategy for MEDLINE is available (S2 File). There will be no restriction on publication date, setting or language. Citations of all identified studies from the search strategy will be exported to EndNote X9 software (Clarivate 2013) and duplicates will be removed using the automated features. Two reviewers (AS and SK) will independently review titles and abstracts and the full-text of any study where eligibility cannot be determined via the title and abstract. Disagreements will be handled through discussion or a third reviewer (UP).

Data extraction and management

Relevant data will be extracted from included studies using a piloted extraction tool in Excel. Data will be extracted by two reviewers (AS and SK) independently and cross checked for accuracy. We will contact the study authors in cases where additional information is required. If there is no response after two contact attempts, we will continue with the data available within the published article.

The following information will be recorded:

  • Study characteristics (title, authors, journal, publication date, study period, number of participants, country, any conflicts of interest, funding source)
  • Study design/methodology (study type, data source/recruitment strategy, eligibility criteria, data analysis)
  • Study population characteristics (age, sex, number of suspected AF cases)
  • Index test(s) (type of digital technology) used
  • Reference test(s) used
  • Outcome (sensitivity and specificity, DOR, PPV, NPV, TP, TN, FP and FN for each mHealth being tested and for each test duration presented)

Risk of bias assessment

The Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS-2) will be used to assess risk of bias independently by two reviewers (AS and SK) [24]. The checklist includes questions on patient selection, index test, reference standard and flow and timing; answers will be noted as yes, no or unclear for signaling questions and high, low or unclear for risk of bias and applicability questions. Bias will not be assessed using one overall score; instead, each question will be tabulated for each study and will be considered within the discussion of our results. The QUADAS-2 tool will be piloted as is and where necessary, the signaling questions will be modified to fit the purpose of our review. Once implemented, any disagreements will be resolved by discussion or a third reviewer (UP).

Analysis

The study selection process will be summarized using a PRISMA diagram [25]. Tables summarizing the study characteristics of included studies, risk of bias (RoB) and quality of evidence will be presented in a summary of findings table.

Excel will be used for data management and R 4.1.1 (R Core Team, 2020) will be used to perform the statistical analysis. We will present the outcomes of sensitivity and specificity using forest plots and will group the studies based on index test first, then by diagnostic threshold of the index test, then by country setting (high-income or low/middle-income) and setting of application (community or healthcare facility). If more than one primary study has the same index test and diagnostic thresholds, heterogeneity will be assessed through the presented forest plots. If there are more than one primary study with the same index test but differing thresholds, heterogeneity will be assessed by observing how well studies fit within the plotted summary receiver operating curve (SROC). If heterogeneity is suspected, a Chi-squared test will be performed. Heterogeneity based on sample size (≤100 participants and >100 participants), sampling method (consecutive/convenience), country setting (high-income vs low/middle-income country) and setting of application (community and healthcare facility) will be explored if necessary. If heterogeneity exists but cannot be explained, a meta-analysis will not be performed and results from included studies will be qualitatively synthesized. Where a meta-analysis is possible for any group of primary studies with the same index test, the sensitivity and specificity will be calculated using a random effect model and pooled effects will be presented within the forest plot of individual study estimates.

Confidence in effect estimates for the outcome measured will be rated according to the quality of evidence using Grading of Recommendation, Assessment, Development and Evaluation (GRADE) approach for diagnostic tests and strategies [26].

Discussion

AF is the most common cardiac arrhythmia worldwide and a major contributor to the global burden of stroke [27]. Early diagnosis of AF can prevent the occurrence of stroke and reduce excess morbidity and mortality [28]. Whilst screening programmes have been found to be clinically effective [29], the 12-lead ECG (gold-standard diagnostic tool for AF) must be used and assessed by a trained clinician within a healthcare facility and can be costly to use in a population-based screening programme [3]. Given 12-lead ECGs are not portable; patients must travel to a healthcare facility to be assessed which is not always accessible or practical and can be costly for the patient and healthcare system, particularly in LMICs where access to healthcare facilities and resources are limited [5,30]. The continuous Holter monitoring device is a useful alternative and is currently the method most used globally to detect suspected AF; however, they are expensive and not commonly available in LMICs. Furthermore, it can be a burden for the patient to carry the device for one or two days [19].

To date, a number of digital technologies have been developed that can be used to diagnose AF, with the added benefits of being portable, patient-friendly and cost effective [10]. Such devices could be particularly beneficial in diagnosing AF in at-risk populations in LMICs where the lack of healthcare access and diagnostic equipment are a known barrier for early AF diagnosis [31]. An improved understanding of what devices have AF diagnostic accuracy data available, and which provide higher accuracy will aid the selection of which devices to further test and use in LMIC settings. Our review findings will therefore provide a clinically important resource for LMICs, where the prevalence of AF is expected to exponentially increase over the next decade [4].

We are only including studies that compare the diagnostic accuracy of digital technologies with a 12-lead ECG; therefore, we may unintentionally exclude many studies that report the diagnostic accuracy of digital technologies, but not against this gold-standard. However, from assessing existing systematic reviews [12,13,15,19,32,33], we do not expect this eligibility criteria to exclude a large number of studies. Furthermore, we feel it is necessary to compare the diagnostic accuracy of these devices to the 12-lead ECG for comparison purposes and to fully understand the potential of using these devices for diagnosing AF. Off-brand named devices may be missed within our search; however, we expect from our search of numerous databases and assessment of references from included studies and existing systematic reviews, the number of studies missed will be reduced. We expect that the methodological quality may be lower for most studies given the observational and descriptive nature of the study designs. Nonetheless, a comprehensive review of all available evidence will be a vital step in understanding what device is best to test and use for diagnosing AF, particularly in low-resourced areas of the world. We will use the findings of our risk and bias assessment to critically assess and synthesize the evidence in a clear and precise manner.

Publication of this research protocol is in keeping with transparent research practice. If any methods outlined in this protocol changes substantially following publication, we will document the amendments. Dissemination of the findings from this review will be done through presenting at academic seminars and conferences and submitting a manuscript to a peer-reviewed journal. This review will provide guidance to a range of stakeholders such as clinicians, primary care doctors and policy makers on the selection of appropriate technology to test and use for early diagnosis of AF.

Supporting information

Acknowledgments

Members of the NIHR Global Health Group on Atrial Fibrillation Management listed in alphabetical order: Ajini Arasalingam, Abi Beane, Isabela M Bensenor, Peter Brocklehurst, Kar Keung Cheng, Itamar S Santos, Wahbi El-Bouri, Mei Feng, Alessandra C Goulart, Sheila Greenfield, Yutao Guo, Mahesan Guruparan, Gustavo Gusso, Tiffany E Gooden, Rashan Haniffa, Lindsey Humphreys, Kate Jolly, Sue Jowett, Balachandran Kumarendran, Emma Lancashire, Deirdre A Lane, Xuewen Li, Gregory Y.H. Lip (Co-PI), Yan-guang Li, Trudie Lobban, Paulo A Lotufo, Semira Manseki-Holland, David J Moore, Krishnarajah Nirantharakumar, Rodrigo D Olmos, Elisabete Paschoal, Paskaran Pirasanth, Uruthirakumar Powsiga, Carla Romagnolli, Alena Shantsila, Vethanayagam Antony Sheron, Kanesamoorthy Shribavan, Isabelle Szmigin, Kumaran Subaschandren, Rajendra Surenthirakumaran, Meihui Tai, Bamini Thavarajah, G. Neil Thomas (Co-PI) Ana C Varella, Hao Wang, Jingya Wang, Hui Zhang, Jiaoyue Zhong.

References

  1. 1. Krijthe BP, Kunst A, Benjamin EJ, Lip GYH, Franco OH, Hofman A, et al. Projections on the number of individuals with atrial fibrillation in the European Union, from 2000 to 2060. Eur Heart J. 2013;34(35):2746–51. pmid:23900699
  2. 2. Gómez-Outes A, Lagunar-Ruíz J, Terleira-Fernández AI, Calvo-Rojas G, Suárez-Gea ML, Vargas-Castrillón E. Causes of Death in Anticoagulated Patients With Atrial Fibrillation. J Am Coll Cardiol. 2016;68(23):2508–21. pmid:27931607
  3. 3. Lewis M, Parker D, Weston C, Bowes M. Screening for atrial fibrillation: sensitivity and specificity of a new methodology. The British Journal of General Practice. 2011 Jan;61(582):38. pmid:21401988
  4. 4. Santos IS, Goulart AC, Olmos RD, Thomas GN, Lip GYH, Lotufo PA, et al. Atrial fibrillation in low- And middle-income countries: A narrative review. European Heart Journal, Supplement. 2020;22:061–77. pmid:33380945
  5. 5. Zoni-Berisso M, Lercari F, Carazza T, Domenicucci S. Epidemiology of atrial fibrillation: European perspective. Clin Epidemiol [Internet]. 2014;6–213. Available from: pmid:24966695
  6. 6. Hamad AKS. New technologies for detection and management of atrial fibrillation. J Saudi Heart Assoc. 2021;33(2):169–76. pmid:34249609
  7. 7. Richardson E, Hall A, Mitchell ARJ. Screening for Atrial Fibrillation and the Role of Digital Health Technologies. In: Cismaru G, Chan KA, editors. Epidemiology and Treatment of Atrial Fibrillation [Internet]. Rijeka: IntechOpen; 2019. p. Ch. 1. Available from: https://doi.org/10.5772/intechopen.88660
  8. 8. Ding EY, Marcus GM, McManus DD. Emerging Technologies for Identifying Atrial Fibrillation. Vol. 127, Circulation Research. Lippincott Williams and Wilkins; 2020. p. 128–42.
  9. 9. Delaporte A, Bahia K. THE STATE OF MOBILE INTERNET CONNECTIVITY 2022 [Internet]. 2022. Available from: www.gsmaintelligence.com
  10. 10. Richardson E, Hall A, R.J. Mitchell . Screening for Atrial Fibrillation and the Role of Digital Health Technologies. Epidemiology and Treatment of Atrial Fibrillation. 2020;1–19.
  11. 11. Lippi G, Sanchis-Gomar F, Cervellin G. Global epidemiology of atrial fibrillation: An increasing epidemic and public health challenge. International Journal of Stroke [Internet]. 2020 Jan 19;16(2):217–21. Available from: pmid:31955707
  12. 12. Prasitlumkum N, Cheungpasitporn W, Chokesuwattanaskul A, Thangjui S, Thongprayoon C, Bathini T, et al. Diagnostic accuracy of smart gadgets/wearable devices in detecting atrial fibrillation: A systematic review and meta-analysis. Arch Cardiovasc Dis. 2021 Jan 1;114(1):4–16. pmid:32921618
  13. 13. Nazarian S, Lam K, Darzi A, Ashrafian H. Diagnostic accuracy of smartwatches for the detection of cardiac arrhythmia: Systematic review and meta-analysis. J Med Internet Res. 2021;23(8). pmid:34448706
  14. 14. Lopez Perales CR, Van Spall HGC, Maeda S, Jimenez A, Laţcu DG, Milman A, et al. Mobile health applications for the detection of atrial fibrillation: A systematic review. Europace. 2021;23(1):11–28. pmid:33043358
  15. 15. Yang TY, Huang L, Malwade S, Hsu CY, Chen YC. Diagnostic accuracy of ambulatory devices in detecting atrial fibrillation: Systematic review and meta-analysis. JMIR Mhealth Uhealth. 2021;9(4). pmid:33835039
  16. 16. O’Sullivan JW, Grigg S, Crawford W, Turakhia MP, Perez M, Ingelsson E, et al. Accuracy of Smartphone Camera Applications for Detecting Atrial Fibrillation: A Systematic Review and Meta-analysis. JAMA Netw Open. 2020 Apr 1;3(4):e202064. pmid:32242908
  17. 17. Belani S, Wahood W, Hardigan P, Placzek AN, Ely S. Accuracy of Detecting Atrial Fibrillation: A Systematic Review and Meta-Analysis of Wrist-Worn Wearable Technology. Cureus. 2021 Dec 12; pmid:35036196
  18. 18. Gill S, Sartini C, Uh H, Ghoreishi N, Cardoso V, Bunting K, et al. Accurate detection of atrial fibrillation using a smartphone remains uncertain: a systematic review and meta-analysis [Internet]. Available from: https://academic.oup.com/eurheartj/article/41/Supplement_2/ehaa946.3505/6002671
  19. 19. Giebel GD, Gissel C. Accuracy of mhealth devices for atrial fibrillation screening: Systematic review. JMIR Mhealth Uhealth. 2019;7(6):1–13. pmid:31199337
  20. 20. Wong KC, Klimis H, Lowres N, Von Huben A, Marschner S, Chow CK. Diagnostic accuracy of handheld electrocardiogram devices in detecting atrial fibrillation in adults in community versus hospital settings: A systematic review and meta-analysis. Vol. 106, Heart. BMJ Publishing Group; 2020. p. 1211–7.
  21. 21. Page MJ, Shamseer L, Tricco AC. Registration of systematic reviews in PROSPERO: 30,000 records and counting. Systematic Reviews 2018 7:1. 2018 Feb 20;7(1):1–9. pmid:29463298
  22. 22. Moher D, Shamseer L, Clarke M, Ghersi D, Liberati A, Petticrew M, et al. Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement. Systematic Reviews 2015 4:1. 2015 Jan 1;4(1):1–9. pmid:25554246
  23. 23. Cochrane Handbook for Systematic Reviews of Interventions | Cochrane Training [Internet]. [cited 2021 Oct 30]. Available from: https://training.cochrane.org/handbook
  24. 24. Reitsma JB, Leeflang MMG, Sterne JAC, Bossuyt PMM, Whiting PF, Rutjes AWSS, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155(4):529–36. pmid:22007046
  25. 25. PRISMA [Internet]. [cited 2021 Oct 30]. Available from: http://prisma-statement.org/prismastatement/flowdiagram.aspx
  26. 26. Guyatt GH, Oxman AD, Vist GE, Kunz R, Falck-Ytter Y, Alonso-Coello P, et al. GRADE: an emerging consensus on rating quality of evidence and strength of recommendations. BMJ. 2008 Apr 24;336(7650):924–6. pmid:18436948
  27. 27. Feigin VL, Norrving B, Mensah GA. Global Burden of Stroke. Circ Res. 2017 Feb 3;120(3):439–48. pmid:28154096
  28. 28. Freedman B. Screening for Atrial Fibrillation A Report of the AF-SCREEN International Collaboration. 2017;1851–67.
  29. 29. Burdett P, Lip GYH. Targeted vs. full population screening costs for incident atrial fibrillation and AF-related stroke for a healthy population aged 65 years in the United Kingdom. Eur Heart J Qual Care Clin Outcomes. 2022;1–7. pmid:35138372
  30. 30. Santos IS, Goulart AC, Olmos RD, Thomas GN, Lip GYH, Lotufo PA, et al. Atrial fibrillation in low- And middle-income countries: A narrative review. Vol. 22, European Heart Journal, Supplement. Oxford University Press; 2020. p. 061–77.
  31. 31. Osei E, Mashamba-Thompson TP. Mobile health applications for disease screening and treatment support in low-and middle-income countries: A narrative review. Heliyon. 2021;7(3):e06639. pmid:33869857
  32. 32. Hermans ANL, Gawalko M, Dohmen L, van der Velden RMJ, Betz K, Duncker D, et al. Mobile health solutions for atrial fibrillation detection and management: a systematic review. Vol. 111, Clinical Research in Cardiology. Springer Science and Business Media Deutschland GmbH; 2022. p. 479–91.
  33. 33. Scarlet, Lam K, Darzi A, Ashrafian H. Diagnostic Accuracy of Smartwatches for the Detection of Cardiac Arrhythmia: Systematic Review and Meta-analysis. J Med Internet Res 2021;23(8):e28974 https://www.jmir.org/2021/8/e28974 [Internet]. 2021 Aug 27 [cited 2021 Sep 20];23(8):e28974. Available from: https://www.jmir.org/2021/8/e28974 pmid:34448706