Abstract
Objectives
Describing mitochondrial oxygenation (mitoPO2) and its within- and between-subject variability over time after 5-aminolevulinic acid (ALA) plaster application in healthy volunteers.
Interventions
Two ALA plasters were placed parasternal left and right, with a 3-hour time interval, to examine the influence of the calendar time on the value of mitoPO2. We measured mitoPO2 at 4, 5, 7, 10, 28, and 31 hours after ALA plaster 1 application, and at 4, 5, 7, 25, and 28 hours after ALA plaster 2 application.
Primary and secondary outcome measures
At each time point, five mitoPO2 measurements were performed. Within-subject variability was defined as the standard deviation (SD) of the mean of five measurements per timepoint of a study participant. The between-subject variability was the SD of the mean mitoPO2 value of the study population per timepoint.
Results
In 16 completed inclusions, median mitoPO2 values and within-subject variability were relatively similar over time at all time points for both plasters. An increase in overall between-subject variability was seen after 25 hours ALA plaster time (19.6 mm Hg vs 23.9 mm Hg after respectively 10 and 25 hours ALA plaster time).
Citation: Baysan M, Broere M, Wille ME, Bergsma JE, Mik EG, Juffermans NP, et al. (2024) Description of mitochondrial oxygen tension and its variability in healthy volunteers. PLoS ONE 19(6): e0300602. https://doi.org/10.1371/journal.pone.0300602
Editor: Gaetano Santulli, Albert Einstein College of Medicine, UNITED STATES
Received: July 20, 2023; Accepted: February 27, 2024; Published: June 3, 2024
Copyright: © 2024 Baysan et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the manuscript and its Supporting Information files.
Funding: This research was financially supported by Grant PPOC-16-31 by VWS-PPOC, Amsterdam, the Netherlands. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Competing interests: I have read the journal’s policy and the authors of this manuscript have the following competing interests: E.G. Mik is a founder and shareholder of Photonics Healthcare B.V. (Utrecht, The Netherlands). Photonics Healthcare develops and commercializes the COMET measuring system for mitochondrial oxygen measurements. The other authors have declared that no competing interests exist. This does not alter our adherence to PLOS ONE policies on sharing data and materials.
Introduction
Adequate tissue and cellular oxygenation is one of the cornerstones of therapy in critically ill patients, which is guided by regular monitoring of the patient’s circulation and oxygenation [1]. Monitoring techniques used for these purposes include mean arterial pressure, lactate, venous-to-arterial carbon dioxide difference, central venous oxygen saturation, near infrared spectroscopy (NIRS) and side stream darkfield (SDF) imaging. These techniques are limited to measurement of microcirculatory or tissue oxygenation. Furthermore, newer techniques like NIRS and SDF measurements are not used as a standard in clinical practice due to its technical limitations and troublesome interpretations [2–6]. For the assessment of cellular oxygenation there are currently no standardized bedside monitoring solutions, but several techniques are being investigated for this purpose [7, 8].
One of them is the cellular oxygen metabolism measurement monitor (COMET) measuring intracellular oxygenation at the end of the oxygen cascade. It has been developed to non-invasively measure oxygen tension in the mitochondria, which is called the mitoPO2, using the oxygen-dependent protoporphyrin IX (PpIX)-triplet state lifetime technique (TSLT) [9, 10]. Exogenous administration of the precursor of PpIX, 5-aminolevulinic acid (ALA), is used as a dye to optimize the measurement of oxygen tension at the mitochondrial level, and to ensure mitochondrial origin of the measurement [10]. A number of studies in animals [11, 12] and humans [13–18], have shown the COMET measurement systems’ robustness and clinical potential as a system to assess cellular oxygenation.
Monitoring of mitoPO2 in critically ill patients with this system, and potentially guide therapy based on the measurements, would require various measurements over a time period after the initial measurements. However, little is known about measurement repeatability of the mitoPO2 measurement with the COMET system [13, 15, 17, 19]. A pilot study evaluating the COMET mitoPO2 measurement system in critically ill patients receiving red blood cell transfusion showed an increase in mitoPO2 values over time, and an increase in the between- and within-subject variability in mitopO2 values during the first 24-hours after ALA-plaster application [20]. This increased variability in the between-subject and within-subject values in the pilot study might have been caused by the instable condition of critically ill patients or might have been caused by the decreased measurement sensitivity of the COMET system after an extended period of measurements after application of ALA-plasters. In the latter case, one would expect to see the same increase in variability in healthy volunteers as in critically ill patients over time [19–21].
The present study therefore aimed to describe the mitoPO2, the within- and between-subject variability of the mitoPO2 values during the first 31 hours after application of the ALA plaster in healthy volunteers.
Materials and methods
Study design
We performed a prospective cohort study in healthy volunteers at Leiden University Medical Center, the Netherlands. We used LUMC notice boards to recruit volunteers. Interested individuals gave written informed consent after assessment of eligibility by a trained study team member. Adult individuals without an active or chronic disease were eligible, while pregnant or breast-feeding women, volunteers with hypersensitivity to brown plaster, and persons with insufficient comprehensibility of the Dutch language were not. Eligible healthy volunteers were recruited from July 1st to September 11th 2020 and were followed-up until October 11th 2020. The healthy volunteers were instructed to refrain from doing sports, perform labored work, or shower during their participation in the study. The institutional ethics committee of Leiden-The Hague-Delft approved the study, as part of a bigger project to study between- and within-subject variability in different cohorts (reference P20.003). The study was conducted according to the declaration of Helsinki and its later amendments. The authors confirm that all ongoing and related trials for this intervention were registered in ClinicalTrials.gov (NCT04626661). We used the Transparent Reporting of Evaluations with Nonrandomized Designs (TREND) checklist when writing our report (S1 Table) [22].
Patient and public involvement
The public and patients were not involved in the preparation and design of the study, students of technical medicine were. The results of the study were shared with the study participants.
Data collection
Demographic, physiological and safety data of each included healthy volunteer were collected at inclusion in an electronic case report form in Castor Electronic Data Capture [23] Demographic data included age, sex, comorbidities, body mass index and smoking status (S1 File). Physiological data included heart rate, blood pressure and peripheral oxygen saturation. During the study measurements, the study team member observed and collected data regarding (serious) adverse event (AE). One week and one month after the last study measurement, data regarding (serious) adverse events were collected via a digital survey, which was send to every participant. The digital survey included the following data: protective measures at measurement locations, duration of these protective measures, observed AE after study measurements (erythema, pain, itching, burning sensation, exfoliation of the skin, blistering, crusting, other), location of AE, duration of AE in days, and severity of AE according to the study participant on a visual analogous scale from 0–10.
Study data were collected using the COMET system (Photonics Healthcare, Utrecht, the Netherlands, CE marked). Description of the PpIX-TSLT technique behind the COMET system can be found in multiple studies [9, 10, 20, 24, 25]. A valid mitoPO2 measurement can be performed after at least four hours after ALA plaster application [10]. The output of a mitoPO2 measurement with the COMET measurement device includes the mitoPO2 value, skin temperature and the signal quality of the measurement [10]. All data were coded to ensure anonymity of the volunteers. Access to identifiable data was restricted to the coordinating investigator (M Baysan) and was only used for follow-up of the healthy volunteers regarding adverse events and monitoring of the study by independent monitors.
Definitions of ALA plaster time, calendar time, between- and within-subject variability
Measurement repeatability has been described as “precision under similar conditions with replicate measurements over a short period of time” [19]. Within-subject and between-subject variability were used to address the measurement repeatability of the mitoPO2 measurement with the COMET measurement device. Within-subject variability was defined as the standard deviation (SD) of the mean of the five measurements per timepoint of a study participant. The between-subject variability was the SD of the mean mitoPO2 of the study population per timepoint. Within-subject variability of the population per timepoint was calculated as the mean SD of the mean of 5 mitoPO2 measurements per timepoint per study participant. Between-subject variability was calculated as the SD of the mean mitoPO2 of the total study population per timepoint.
To study the variability of mitoPO2 over time, we applied two plasters at the left and right side of the sternum, 3–5 centimeters apart. We applied the second plaster, three hours after the first plaster. Our assumption hereby was that despite heterogenous oxygen distribution in the skin, mitoPO2 values measured at the left and right of the sternum at the same time, would be comparable. The aim was to collect mitoPO2 measurements on two time scales: calendar time and plaster time. Calendar time was defined as the time of the day the measurement was performed. ALA plaster time was defined as the number of hours since application of the ALA plaster. With two plasters, applied with three hours’ time difference, we assumed to be able to discern the effect of duration of application and time of the day on the mitoPO2.
Study procedure
We performed the study with two ALA plasters and we pragmatically used a study duration of 31 hours based on the combination of 24-hour study duration in the aforementioned pilot study and logistics of the current study [20].
After the informed consent procedure, the healthy volunteers were given oral and written instructions, ALA plasters of 2x2cm (Alacare, Photonamic GmbH, Wedel, Germany) and alcohol patches. Participants were instructed to place the first ALA plaster parasternal at 7 A.M. on measurement day, after firmly cleaning the anterior chest wall with alcohol. Three hours later, at 10 A.M., a study team member placed a second ALA plaster at the opposite parasternal location, after cleaning it with alcohol. Thus, two ALA-plasters were in place with a 3-hour time interval, one on each side of the sternum, to be able to compare ALA plaster time (i.e. the time that has passed since the plaster was administered) with calendar time (i.e. the actual time of the measurement). The study team member marked the circumference of each ALA plaster. After placement of the participant in supine position, the first ALA plaster was temporarily removed after four hours induction of PpIX. The removed ALA patch was kept next to the participant during the measurements with the COMET measurement device. One to two minutes after removal of the ALA patch, the COMET measurement device was gently placed on the skin by a study team member, within the marked circumference of the removed ALA plaster to start the mitoPO2 measurements. Directly following the five mitoPO2 measurements at the respective timepoints, the removed ALA plaster was re-placed on the skin to protect the exposed skin against phototoxicity. This procedure was repeated for each plaster at each timepoint.
MitoPO2 measurements consisted of a validation phase and a measurement phase. During the validation phase, a PpIX-TSLT signal quality of ≥25% during the measurement at measurement location was needed for the mitoPO2 measurements to be valid [20]. The signal quality of the mitoPO2 measurement was measured by the COMET measurement device itself, where a higher signal quality corresponds with a more robust mitoPO2 measurement. The mitoPO2 measurement was additionally validated by occlusion of the microcirculation at measurement location, by applying local pressure on the measurement device. In doing this, an immediate drop in mitoPO2 level was expected, as well as a fast recovery after release of the pressure on the microcirculation [10, 20]. After this validation procedure, mitoPO2 was measured once per minute for five minutes, to obtain a mean mitoPO2, with its corresponding SD for each participant at each time point. To minimize movement artifacts, the measurement probe was stabilized at the measurement location by manually holding the cable at the end of the measurement probe. To minimize the effect of different light conditions on the PpIX utilization, the room lights were turned off during all measurements.
The timepoints for mitoPO2 measurements with the first ALA plaster were 4, 5, 7 10, 28, and 31 hours after ALA plaster application (ALA plaster time), while the timepoints for the second ALA plaster were at 4, 5, 7, 25, and 28 hours ALA plaster time. This corresponded with calendar time of 11 A.M. (only plaster 1), 12 P.M. (only plaster 1), 2 P.M. (plaster 1 and 2), 3 P.M. (only plaster 2), 5 P.M. (plaster 1 and 2), 12 P.M. the next day (plaster 1 and 2), and 3 P.M. the next day (plaster 1 and 2) for these measurements. The timepoints were chosen to get insight into the course of the between- and within-subject variability over time, while keeping the study logistically manageable.
After completion of all measurements, the exposed skin was protected from sunlight for an additional 24 hours with a waterproof plaster (Kliniplast border, Medeco, Oud-Beijerland, the Netherlands). The participants were given instructions to minimize sun exposure on the ALA plaster locations for at least 24 hours. A schematic overview of the study procedure and mitoPO2 measurement can be found in S1 and S2 Figs.
Statistical analyses
The sample size of 17 subjects was calculated to achieve a statistical power of 90%, with a significance level of 5%, to test for differences in one-sample mean within-subject variability of 8.7 mm Hg to 4mm Hg, with a standard deviation of 5.67 mm Hg and a drop-out rate of 10%, as depicted in the study protocol. The study population characteristics, signal quality and skin temperature per timepoint and per plaster were described using mean and SD, or median and interquartile ranges (IQR), as appropriate. Categorical variables were presented as number (percentage). The mitoPO2, its within-subject variability and between-subject variability of each plaster at each time point were described using respectively median mitoPO2 (IQR), median within-subject variability (IQR), and SD of mean mitoPO2. Overall mitoPO2, and overall within-subject variability were calculated using the median value of the composed data of plaster 1 and 2 in concurrent measurement time points, while the between-subject variability was based on the SD of the mean mitoPO2 of the composed data of plaster 1 and 2. Concurrent measurements of plaster 1 and 2 were performed at 4,5,7 and 28 hours ALA plaster time, which corresponds with the measurements respectively at 2 P.M., 5 P.M., 12 P.M.(+1 day), and 3 P.M.(+1 day) calendar time. The mitoPO2 and within-subject variability were visualized using a boxplot and spaghetti plot. Between-subject variability was visualized using error bars and a spaghetti plot. Data regarding adverse events were described with number (percentage). All analyses were performed using R (R foundation for Statistical Computing, Vienna, Austria) [26].
Results
Characteristics of study population
After assessment of eligibility, 18 healthy volunteers were included in this study, 16 were analyzed (Fig 1). One healthy volunteer was excluded due to brown plaster allergy. Another healthy volunteer was excluded from the analyses, since no valid mitoPO2 measurement could be achieved during the study. The signal quality of this volunteer remained below 25% after multiple efforts. Furthermore, no decrease of mitoPO2 could be seen after application of pressure on the measurement device at each timepoint in this volunteer. The mean age of the included 16 participants was 22.4 (SD 1.8) years, ten were female (62.5%). Further details of the study population are depicted in Table 1.
MitoPO2 measurement characteristics
Median sensor temperature was 30.4 (IQR 29.6–30.7) ⁰C in plaster 1 and 31.8 (IQR 31.7–32.2) ⁰C in plaster 2. The median sensor temperature remained between 30.0–30.7 ⁰C in plaster 1, while it was between 30.4–32.0 ⁰C in plaster 2 (S2 Table). The median signal quality was 33.2 (IQR 29.5–35.6) % in plaster 1 and 31.2 (IQR 29.0–34.4) % in plaster 2 after 4 hours after ALA plaster application. The median signal quality increased after 7 hours ALA plaster time to 41.0 (IQR 31.0–49.9) % in plaster 1 and 47.8 (IQR 44.7–62.7) % in plaster 2. The signal quality remained above the limit of 25% during all measurements (S2 Table). Furthermore, there were data missing after 4 hours ALA plaster time in plaster 1 in 4 participants (S3 Table), which was due to poor validation measurement performances in 3 participants and no measurement in 1 participant. After 5 hours ALA plaster time in plaster 1, there was 1 volunteer with remaining poor validation measurement performances. There were no missing data in measurements with plaster 2 or in later timepoints for plaster 1. The mitoPO2 values and within-subject variability values were not normally distributed at each time point, both at ALA plaster time and calendar time (S3 and S4 Figs).
Course of mitoPO2
Calendar time.
The median mitoPO2 of plaster 1 at 2 P.M. was 37.5 (IQR 28.2–66.2) mm Hg, while it was 45.9 (IQR 37.6–54.7) mm Hg in plaster 2 (Table 2). At 5 P.M. the median mitoPO2 of plaster 1 was 45.2 mm Hg (IQR 36.8–60.2), while it was 45.5 (IQR 41.2–50.2) mm Hg in plaster 2. The measurement at 12 P.M. the following day resulted in a median mitoPO2 of 50.3 (IQR 26.5–57.1) mm Hg and 48.2 (IQR 28.1–61.8) mm Hg in respectively plaster 1 and 2. Similar results were seen at 3 P.M. the following day with a median mitoPO2 of 38.5 (IQR 30.1–51.8) mm Hg in plaster 1 and 40.0 (IQR 29.0–50.3) mm Hg in plaster 2. A small difference in median mitoPO2 was only seen between the plasters at 2 P.M., while the median mitoPO2 values were relatively steady over the remaining calendar time (S5 Fig).
Plaster 2 was placed 3 hours after plaster 1 was placed. Despite a difference in the value of median mitoPO2 at 2 P.M., the median mitoPO2 values seem relatively steady over the remaining calendar times. The within-subject variability remains stable over time in each plaster, while an increase in between-subject variability can be seen in plaster 2.
Plaster time.
The median mitoPO2 after 4 hours ALA plaster time was 46.6 (IQR 38.0–57.4) mm Hg, 42.4 (IQR 34.8–53.4) mm Hg after 5 hours ALA plaster time, 44.1 (IQR 33.6–56.7) mm Hg after 7 hours ALA plaster time, 45.2 (IQR 36.8–60.2) mm Hg after 10 hours ALA plaster time, 48.2 (IQR 28.1–61.8) mm Hg after 25 hours ALA plaster time, 46.3 (IQR 28.8–54.4) mm Hg after 28 hours plaster ALA time, and 38.5 (IQR 30.1–51.8) mm Hg after 31 hours ALA plaster time (Table 3 and S6 Fig). The course of the individual mitoPO2 values over ALA plaster time showed similar results (S7 Fig). A small difference in median mitoPO2 values were only seen between the plasters after 5, 7 and 28 hours ALA plaster time, while the median mitoPO2 values were relatively steady over the remaining calendar time (Fig 2).
The median mitoPO2 appears to be relatively steady over time in both plasters, despite a small difference in median mitoPO2 and its corresponding interquartile range after 5,7, and 28 hours ALA plaster time between plaster 1 and 2. This difference is not seen in the mean mitoPO2 values at that timepoint (Table 3).
The mitoPO2 and within-subject variability remains stable over time, while an increase in between-subject variability can be seen after 25 hours ALA plaster time.
Overall, the value of mitoPO2 remained relatively stable over time, both in calendar time (Table 2, S5 and S9 Figs) and in ALA plaster time (Table 3, Fig 2 and S6 Fig).
Within-subject variability
The individual within-subject variability and the overall median within-subject variability showed no marked increase of the within-subject variability over ALA plaster time (Tables 2 and 3, S4 Table, S8 and S10 Figs).
The within-subject variability per plaster over calendar time and ALA plaster time, showed small differences in median within-subject variability at 5 P.M. and 5 hour ALA plaster time respectively (S11–S13 Figs). S5 Table shows that the median within-subject variability after 5 hours ALA plaster time was 6.4 (IQR 5.0–12.8) mm Hg in plaster 1 and 12.7 (IQR 10.5–15.1) mm Hg in plaster 2.
The median within-subject variability over ALA plaster time was 6.8 mm Hg (IQR 4.1–10.1) mm Hg after 4 hours ALA plaster time, 11.5 (IQR 6.3–13.8) mm Hg after 5 hours ALA plaster time, 8.0 (IQR 4.2–12.6) mm Hg after 7 hours ALA plaster time, 7.4 (IQR 5.0–10.8) mm Hg after 10 hours ALA plaster time, 6.9 (IQR 4.1–13.4) mm Hg after 25 hours ALA plaster time, 8.4 (IQR 5.5–12.6) mm Hg after 28 hours ALA plaster time, and 6.3 (IQR 4.5–11.0) mm Hg after 31 hours ALA plaster time (Table 3).
Between-subject variability
An increase in between-subject variability could be seen in calendar time from 12 P.M. next day on in both the overall between-subject variability and the between-subject variability per plaster (S14 and S15 Figs). An increase in the overall between-subject variability was observed from 17.3 mm Hg at 5 P.M. to 22.8 mm Hg at 12 P.M. the following day (S4 Table).
The between-subject variability was 16.9 mm Hg after 4 hours ALA plaster time, 14.5 mm Hg after 5 hours ALA plaster time, 18.5 mm Hg after 7 hours ALA plaster time, 19.6 mm Hg after 10 hours ALA plaster time, 23.9 mm Hg after 25 hours ALA plaster time, 22.6 mm Hg after 28 hours ALA plaster time, and 24.8 mm Hg after 31 hours ALA plaster time (Table 3). The increase of overall between-subject variability over ALA plaster time was reflected in S16 Fig, showing an increase in between-subject variability after 25 hours ALA plaster time. This increase was more pronounced in plaster 2 than in plaster 1 (S17 Fig).
Adverse events
All healthy volunteers developed adverse events during the study measurements, as depicted in S6 Table, ranging from erythema (n = 15, 94%), itching (n = 15, 94%) to hyperpigmentation of the skin (n = 2, 13%). All adverse events resolved within 1 month after the last measurement. An overview of the adverse events and their course over time are depicted in S6 Table. Nine of the participants (56%) experienced their adverse events as only mild in unpleasantness. Six felt moderate unpleasantness due to their adverse events, while one participant did not report the severity of the adverse event. The compliance rate of the healthy volunteers with the protection instructions was 94% (n = 15). One volunteer only applied protection for one night, 10 volunteers protected the locations for 48 hours (63%), and 5 volunteers (32%) applied protection for even longer than two days, ranging from 72 hours up until a month. The manner of protection was as follows: 10 protected with clothing, 4 with the given plaster for protection at the end of the measurement moments, 1 with the plaster and clothing and 1 with clothing and sunscreen.
Discussion
We performed a study to describe the mitoPO2, the within- and between subject variability of the mitoPO2 values during the first 31 hours after application of the ALA plaster in healthy volunteers. The mitoPO2 was relatively stable over a period of 28 hours of ALA plaster time with a median range of 42.4–48.2 mm Hg, while there was a decline at 31 hours ALA plaster time. Furthermore, the within-subject variability of mitoPO2 showed no marked increase over a period of 31 hours ALA plaster time. Interestingly the between-subject variability was slightly increased 25-hours after application of the ALA plaster.
Previous studies using the COMET system, have performed mitoPO2 measurements over a period of up to 6 hours ALA plaster time [13, 15–18]. Only a few of these studies have described their between-subject and/or within-subject variability of the mitoPO2 measurements over time, concluding moderate repeatability of the mitoPO2 measurements using the COMET system over a short period of time [15, 17]. As stated earlier, the repeatability is a characteristic of a measurement system indicating the precision of the measurement under similar conditions with replicate measurements over time [19]. We previously performed mitoPO2 measurements with 24-hours ALA plaster time using the COMET system in critically ill patients and showed an increase of both within-subject and between-subject variability after 3 hours, implicating diminished repeatability of the COMET system over a period of time [20]. However, our current results show that the within-subject variability and mitoPO2 measured with the COMET system are relatively repeatable up until 28 hours ALA plaster time in healthy volunteers, but that between-subject variability increases after 25 hours. We therefore recommend that the ALA plaster is replaced with a new plaster after 24 hours when mitoPO2 measurements with the COMET system are performed.
Biologically, 24 hours after ALA induction normalization of PpIX levels is expected, with a peak fluorescence after 4–14 hours ALA plaster time and limited PpIX fluorescence detectability after 24 hours [27, 28]. The diminished fluorescence of PpIX after 4–14 hours ALA plaster time might explain the increased between-subject variability seen in our study after 25 hours ALA plaster time. However, even after 25–31 hours ALA plaster time, the signal quality of the measurements remained above 25%, suggesting the fluorescence signal of PpIX was still substantial and not causing the increase in the between-subject variability. The biological mechanism of the increase in between-subject variability after 25 hours ALA plaster time is therefore not fully understood with the current knowledge.
Furthermore, our results showed that longer time since application of ALA plaster resulted in better signal quality, especially after 5 hours ALA plaster time, strengthening the earlier report of the correlation between ALA plaster time and the signal quality [17]. In one participant we did not gain sufficient signal quality for our measurements despite protocol adherence. Despite 7 hours of ALA plaster time, no increase in signal quality was seen. Furthermore, no drop in mitoPO2 values was seen in this heathy volunteer after occlusion of the microcirculation. Looking into patient characteristics, the only difference with other participants was that this participant had a dark skin tone. It is known that the depth of COMET measurement is dependent on the stratum corneum thickness [10], which has been associated with sun exposure, smoking (negative association), and pigmentation independent of sun exposure [29, 30]. Further investigation is needed to clarify these effects on the mitoPO2 measurement with the COMET measurement device. The manufacturer was notified, but the cause of the low signal quality was not completely understood.
Interestingly, an unexpected high incidence of adverse events was seen in our study, since 100% of the healthy volunteers developed local adverse events during the measurements. Previously reported incidence of adverse events of mitoPO2 measurements was 45% in healthy volunteers [31], while minimal to no adverse events have been reported in mitoPO2 measurements with critically ill patients [15, 20, 32]. As in previous studies, the adverse events were present at the measurement sites up to one month after the last mitoPO2 measurement. The higher incidence of adverse events in this study compared to the study of Harms et al. could partly be explained by the difference in measurement devices and total ALA plaster time. We used the COMET measurement device for the mitoPO2 measurements, while the study of Harms et al. reported measurements with the precursor of the COMET device. The total ALA plaster time in the study of Harms et al. was 5 hours, while it was 31 hours in our study [31]. No detailed information was given regarding protective measures of the PpIX induced skin in the study of Harm et al., while we used an island plaster [8]. Other studies have used an occlusive dressing or a plaster as protective measures which could contribute to variation in incidence of adverse events [8, 13]. Non-compliance to instructions, might not fully explain the high incidence of adverse events, since one participant did not protect the measurement site for at least 24 hours, which resulted in hyperpigmentation of the skin after the measurements for a month, after which the hyperpigmentation resolved. Furthermore, the cumulative dose of light at the measurement site could not explain the increased incidence of adverse events, since similar cumulative dose of light at measurement sites in critically ill patients did result in low incidence of adverse events [20]. We advise to use occlusive dressings after ALA plaster application to minimize the risk of adverse events in future mitoPO2 measurements with the COMET measurement device.
A strength of our study was that we strictly protocolized the measurement procedure, with strict instructions to participants, timing of measurements, dark environment during the measurements, supine position of the participants during the measurements, and the application of 2 ALA plasters 3 hours apart from each other. Therefore, the measurement conditions could have had minimal influence [19].
One of the study limitations included possible effects of small movements of the measurement probe on the within-subject variability during measurements [31], which were minimised by using gentle pressure on the cable of the measurement device to fixate the measurement probe. MitoPO2 measurement at the anterior chest wall in supine position strengthened the stabilization of the measurement probe despite respiratory movements of the chest wall. A double-sided plaster for fixation of the measurement probe is now handed out by the manufacturer to further minimise the effect of movement artefacts of the measurement probe on measurement variability [14, 32]. Despite no availability of double-sided plaster during the measurements in this study, the within-subject variability over time was within acceptable limits as described in previous studies [15, 17]. A within-subject variability of approximately 11.71 mm Hg was seen in replicate mitoPO2 measurements 10 minutes apart from each other in a study in healthy volunteers [17]. Similar results were seen in a feasibility study with critically ill patients with sepsis. Repetitive mitoPO2 measurements before and after local occlusion of the microcirculation resulted in within-subject variabilities of 13.62 mm Hg before occlusion and 11.24 mm Hg after occlusion [15]. However, the absolute within-subject variability was higher than seen in our pilot study, possibly due the movement artefacts [20]. We therefore advise to use the double-sided plaster to fixate the measurement probe, thereby improving the mitoPO2 measurement precision.
During the validation phase of the mitoPO2 measurements, we assumed that the local perfusion of the measurement location was not impaired in healthy volunteers. We did not perform any measurements to assess the local perfusion. In future studies, capillary refill time could be an instrument to assess the local perfusion, while keeping in mind the factors influencing the capillary refill time including ambient temperature [33, 34].
Another limitation of our study is our study size leading to broader confidence intervals, attenuating the careful interpretation of our results.
The results of this study suggest that the previously reported increased mitoPO2 and within-subject variability over a 24-hour time period in critically ill patients, is not a consequence of ALA plaster time. The repeatability of the mitoPO2 measurements seem reliable and robust in healthy volunteers, however an increased between-subject variability was seen over time. Possible explanations for the observed increased between-subject variability need to be examined in future studies [20]. Possibly it is the consequence of diminished fluorescence properties or clearance of the ALA enhanced PpIX after 24 hours [35] or other unknown biomechanical factors. Current studies with the COMET device are mostly focused on monitoring mitoPO2 in critically ill patients in the ICU and operation room. However, mitoPO2 measurements might be an additional tool in other settings as well [36]. For example, mitoPO2 might be an additional tool to assess sleep apnea severity, like serum Romo1 [37]. The COMET device could also be useful in assessment of mitoPO2 in COVID-19 patients and its possible association with balance disorders [38]. However, there is currently no evidence to support these uses and future studies into specific patient population are needed.
Conclusions
The mitoPO2 values and within-subject variability remained relatively steady in healthy volunteers during the first 31 hours after ALA plaster application, with a median mitoPO2 of 42.4–48.2 mm Hg and within-subject variability of 6.3–11.5 mm Hg respectively, suggesting no deleterious effect of prolonged ALA plaster time. However, an increase in between-subject variability was seen after 25 hours ALA plaster time warranting replacement of the ALA plaster one day after its application. Validation of these results are needed in future studies and in different study populations.
Supporting information
S2 Fig. Overview of the standardized mitoPO2 measurement per timepoint.
The measurement was standardized to minimize influence of different measurement techniques on the result of the within-subject and between-subject variability.
https://doi.org/10.1371/journal.pone.0300602.s002
(TIF)
S3 Fig. Histograms of distribution of mitoPO2 over ALA plaster time.
The histograms show normal distribution of mitoPO2 after 4 and 7 hours ALA plaster time. At remaining timepoints, no normal distribution of the mitoPO2 values is seen.
https://doi.org/10.1371/journal.pone.0300602.s003
(TIF)
S4 Fig. Histograms of distribution of mitoPO2 over calendar time.
The histograms show normal distribution of mitoPO2 at 11 A.M. and 2 P.M. At remaining timepoints, no normal distribution of the mitoPO2 values is seen.
https://doi.org/10.1371/journal.pone.0300602.s004
(TIF)
S5 Fig. A boxplot of the course of mitoPO2 over calendar time per plaster.
The median mitoPO2 appears to be relatively steady over time in both plasters, despite a small difference in median mitoPO2 and its corresponding interquartile range at 2 P.M. between plaster 1 and 2. This difference is not seen in the mean mitoPO2 values at that timepoint (Table 2).
https://doi.org/10.1371/journal.pone.0300602.s005
(TIF)
S6 Fig. The course of the overall median mitoPO2 over ALA plaster time.
Concurrent measurements were performed at 4,5,7 and 28 hours ALA plaster time in plaster 1 and 2. The median mitoPO2 appears to be relatively steady over ALA plaster time.
https://doi.org/10.1371/journal.pone.0300602.s006
(TIF)
S7 Fig. Spaghetti plot of the course of the overall median mitoPO2 over ALA plaster time.
A range of mitoPO2 values between 20–60 mm Hg can be seen after 4 hours ALA plaster time, which remains relatively stable up to 31 hours ALA plaster time.
https://doi.org/10.1371/journal.pone.0300602.s007
(TIF)
S8 Fig. Spaghetti plot of the overall median within-subject variability over ALA plaster time per participant.
A range of within-subject variability between 3-13mmHg can be seen after 4 hour ALA plaster time which remains relatively steady up to 31 hours ALA plaster time. Small outliers can be seen at 10 and 25 hours ALA plaster time, probably due to measurements with only one plaster instead of 2 plasters.
https://doi.org/10.1371/journal.pone.0300602.s008
(TIF)
S9 Fig. The course of the overall median mitoPO2 over calendar time.
Concurrent measurements were performed at 2 P.M., 5 P.M., 12 P.M.(+1), and 3 P.M.(+1) in plaster 1 and 2. The median mitoPO2 appears to be relatively steady over both calendar time.
https://doi.org/10.1371/journal.pone.0300602.s009
(TIF)
S10 Fig. The course of the overall median within-subject variability over ALA plaster time.
Concurrent measurements were performed at 2 P.M., 5 P.M., 12 P.M.(+1), and 3 P.M.(+1) in plaster 1 and 2. The median within-subject variability appears to be relatively steady over ALA plaster time.
https://doi.org/10.1371/journal.pone.0300602.s010
(TIF)
S11 Fig. The course of the overall median within-subject variability over calendar time.
Concurrent measurements were performed at 4,5,7 and 28 hours ALA plaster time in plaster 1 and 2. The median within-subject variability appears to be relatively steady over calendar.
https://doi.org/10.1371/journal.pone.0300602.s011
(TIF)
S12 Fig. The course of the within-subject variability over calendar time per plaster.
The median within-subject variability appears to be relatively steady over time in both plasters. A small difference in median within-subject variability was seen at 5 P.M. between plaster 1 and 2.
https://doi.org/10.1371/journal.pone.0300602.s012
(TIF)
S13 Fig. The course of the within-subject variability over ALA plaster time per plaster.
The median within-subject variability appears to be relatively steady over time in both plasters. A small difference in median within-subject variability was seen at 5 hours ALA plaster time between plaster 1 and 2.
https://doi.org/10.1371/journal.pone.0300602.s013
(TIF)
S14 Fig. The course of the overall mean mitoPO2 and its corresponding between-subject variability over calendar time.
The dots correspond with the mean mitoPO2, while the line corresponds with the standard deviation and therefore the between-subject variability. Concurrent measurements were performed at 2 P.M., 5 P.M., 12 P.M.(+1), and 3 P.M.(+1) in plaster 1 and 2. The between-subject variability appears to increase after 12 P.M.(+1).
https://doi.org/10.1371/journal.pone.0300602.s014
(TIF)
S15 Fig. The course of the mean mitoPO2 and its corresponding between-subject variability over calendar time.
The dots correspond with the mean mitoPO2, while the line corresponds with the standard deviation and therefore the between-subject variability. Concurrent measurements were performed at 2 P.M., 5 P.M., 12 P.M.(+1), and 3 P.M.(+1)in plaster 1 and 2. The between-subject variability appears to increase after 12 P.M.(+1 in especially plaster 2.
https://doi.org/10.1371/journal.pone.0300602.s015
(TIF)
S16 Fig. The course of the overall mean mitoPO2 and its corresponding between-subject variability over ALA plaster time.
The dots correspond with the mean mitoPO2, while the line corresponds with the standard deviation and therefore the between-subject variability. Concurrent measurements were performed at 4,5,7 and 28 hours ALA plaster time in plaster 1 and 2. The between-subject variability appears to increase after 25 hours ALA plaster time.
https://doi.org/10.1371/journal.pone.0300602.s016
(TIF)
S17 Fig. The course of the mean mitoPO2 and its corresponding between-subject variability over ALA plaster time per plaster.
The dots correspond with the mean mitoPO2, while the line corresponds with the standard deviation and therefore the between-subject variability. Concurrent measurements were performed at 4,5,7 and 28 hours ALA plaster time in plaster 1 and 2. The between-subject variability appears to increase after 25 hours ALA plaster time in especially plaster 2.
https://doi.org/10.1371/journal.pone.0300602.s017
(TIF)
S1 Table. Checklist of items that should be included in this manuscript.
https://doi.org/10.1371/journal.pone.0300602.s018
(PDF)
S2 Table. An overview of characteristics of the mitoPO2 measurements with the COMET probe.
The course of the overall median skin temperature and signal quality over ALA plaster time are depicted, as well as the median skin temperature and signal quality per plaster over ALA plaster time.
https://doi.org/10.1371/journal.pone.0300602.s019
(PDF)
S3 Table. Overview of missing data in the study population.
There was only missing data in plaster 1 after 4 and 5 hours ALA plaster time due to poor calibration measurement performances.
https://doi.org/10.1371/journal.pone.0300602.s020
(PDF)
S4 Table. The course of the overall median mitoPO2, between-subject variability and the median within-subject variability over calendar time.
Plaster 2 was placed 3 hours after plaster 1 was placed. An increase in between-subject variability can be seen after 12 P.M. the next day.
https://doi.org/10.1371/journal.pone.0300602.s021
(PDF)
S5 Table. The course of the median mitoPO2, between-subject variability and the median within-subject variability over ALA plaster time per plaster.
Plaster 2 was placed 3 hours after plaster 1 was placed. The mitoPO2 and within-subject variability remains relatively stable over time in each plaster, while an increase in between-subject variability can be seen after 25 hours ALA plaster time in plaster 2 and after 28 hours in plaster 1.
https://doi.org/10.1371/journal.pone.0300602.s022
(PDF)
S6 Table. Adverse events during and after study measurements.
https://doi.org/10.1371/journal.pone.0300602.s023
(PDF)
S1 File. A CSV file of our study database, which we used for the analyses in this manuscript.
https://doi.org/10.1371/journal.pone.0300602.s024
(CSV)
Acknowledgments
The authors thank the healthy volunteers for participation in this study. Furthermore, we would like to thank the colleagues of the Anesthesiology department of Leiden University Medical Center for their help. The authors acknowledge the helpful comments from Aad Pors and Camila Caram-Deelder in the data management of this study.
References
- 1. Bronicki RA. Hemodynamic monitoring. Pediatr Crit Care Med. 2016;17(8 Suppl 1): S207–14.
- 2. Sanfilippo F, La Via L, Tigano S, Astuto M. Establishing the role of cerebral oximetry during cardio-pulmonary resuscitation of cardiac arrest patients. Resuscitation. 2021;164: 1–3. pmid:33961958
- 3. Ali J, Cody J, Maldonado Y, Ramakrishna H. Near-Infrared Spectroscopy (NIRS) for cerebral and tissue oximetry: analysis of evolving applications. J Cardiothorac Vasc Anesth. 2022;36(8 Pt A): 2758–66. pmid:34362641
- 4. De Backer D, Cecconi M, Chew MS, Hajjar L, Monnet X, Ospina-Tascon GA, et al. A plea for personalization of the hemodynamic management of septic shock. Crit Care. 2022;26(1): 372. pmid:36457089
- 5. Ince C. Hemodynamic coherence and the rationale for monitoring the microcirculation. Crit Care. 2015;19 Suppl 3(Suppl 3): S8. pmid:26729241
- 6. Hallisey SD, Greenwood JC. Beyond mean arterial pressure and lactate: perfusion end points for managing the shocked patient. Emerg Med Clin North Am. 2019;37(3): 395–408. pmid:31262411
- 7. Kara A, Akin S, Ince C. Monitoring microcirculation in critical illness. Curr Opin Crit Care. 2016;22(5): 444–52. pmid:27583585
- 8. Dubin A, Henriquez E, Hernandez G. Monitoring peripheral perfusion and microcirculation. Curr Opin Crit Care. 2018;24(3): 173–80. pmid:29553951
- 9. Mik EG. Special article: measuring mitochondrial oxygen tension: from basic principles to application in humans. Anesth Analg. 2013;117(4): 834–46. pmid:23592604
- 10. Ubbink R, Bettink MAW, Janse R, Harms FA, Johannes T, Munker FM, et al. A monitor for Cellular Oxygen METabolism (COMET): monitoring tissue oxygenation at the mitochondrial level. J Clin Monit Comput. 2017;31(6): 1143–50. pmid:28000040
- 11. Wefers Bettink MA, Harms FA, Dollee N, Specht PAC, Raat NJH, Schoonderwoerd GC, et al. Non-invasive versus ex vivo measurement of mitochondrial function in an endotoxemia model in rat: Toward monitoring of mitochondrial therapy. Mitochondrion. 2020;50: 149–57. pmid:31770610
- 12. Mandigers L, Pooth JS, Wefers Bettink MA, den Uil CA, Damjanovic D, Mik EG, et al. Monitoring mitochondrial partial oxygen pressure during cardiac arrest and extracorporeal aardiopulmonary resuscitation. An experimental pilot study in a pig model. Front Cardiovasc Med. 2021;8: 754852.
- 13. Ubbink R, Prens EP, Mik EG. Quantitative intracellular oxygen availability before and after 5-aminolevulinic acid skin photodynamic therapy. Photodiagnosis Photodyn Ther. 2021;36: 102599. pmid:34699980
- 14. Ubbink R, Wefers Bettink MA, van Weteringen W, Mik EG. Mitochondrial oxygen monitoring with COMET: verification of calibration in man and comparison with vascular occlusion tests in healthy volunteers. J Clin Monit Comput. 2021;35(6): 1357–66. pmid:33085071
- 15. Neu C, Baumbach P, Plooij AK, Skitek K, Gotze J, von Loeffelholz C, et al. Non-invasive assessment of mitochondrial oxygen metabolism in the critically ill patient using the protoporphyrin IX-triplet state lifetime technique-a feasibility study. Front Immunol. 2020;11: 757. pmid:32457741
- 16. Baumbach P, Schmidt-Winter C, Hoefer J, Derlien S, Best N, Herbsleb M, et al. A pilot study on the association of mitochondrial oxygen metabolism and gas exchange during cardiopulmonary exercise testing: is there a mitochondrial threshold? Front Med (Lausanne). 2020;7: 585462. pmid:33409287
- 17. Baumbach P, Neu C, Derlien S, Bauer M, Nisser M, Buder A, et al. A pilot study of exercise-induced changes in mitochondrial oxygen metabolism measured by a cellular oxygen meatabolism monitor (PICOMET). Biochim Biophys Acta Mol Basis Dis. 2019;1865(4): 749–58.
- 18. Harms FA, Ubbink R, de Wijs CJ, Ligtenberg MP, Ter Horst M, Mik EG. Mitochondrial oxygenation during cardiopulmonary bypass: a pilot study. Front Med (Lausanne). 2022;9: 785734. pmid:35924039
- 19. Squara P, Imhoff M, Cecconi M. Metrology in medicine: from measurements to decision, with specific reference to anesthesia and intensive care. Anesth Analg. 2015;120(1): 66–75. pmid:25625255
- 20. Baysan M, Arbous MS, Mik EG, Juffermans NP, van der Bom JG. Study protocol and pilot results of an observational cohort study evaluating effect of red blood cell transfusion on oxygenation and mitochondrial oxygen tension in critically ill patients with anaemia: the INsufficient Oxygenation in the Intensive Care Unit (INOX ICU-2) study. BMJ Open. 2020;10(5): e036351. pmid:32423938
- 21. Vincent JL. The coming era of precision medicine for intensive care. Crit Care. 2017;21(Suppl 3): 314. pmid:29297399
- 22. Des Jarlais DC, Lyles C, Crepaz N, Group T. Improving the reporting quality of nonrandomized evaluations of behavioral and public health interventions: the TREND statement. Am J Public Health. 2004;94(3): 361–6. pmid:14998794
- 23.
Castor EDC. Castor Electornic Data Capture [Internet]. 2019 [Cited 2023 August 28]. Available from: https://castoredc.com.
- 24. Lo LW, Koch CJ, Wilson DF. Calibration of oxygen-dependent quenching of the phosphorescence of Pd-meso-tetra (4-carboxyphenyl) porphine: a phosphor with general application for measuring oxygen concentration in biological systems. Anal Biochem. 1996;236(1): 153–60. pmid:8619481
- 25. Mik EG, Balestra GM, Harms FA. Monitoring mitochondrial PO2: the next step. Curr Opin Crit Care. 2020;26(3): 289–95. pmid:32348095
- 26.
R Core Team. R: A language and environment for statistical computing [Internet]. Vienna, Austria;2016. Available from: https://www.R-project.org.
- 27. Wachowska M, Muchowicz A, Firczuk M, Gabrysiak M, Winiarska M, Wanczyk M, et al. Aminolevulinic Acid (ALA) as a prodrug in photodynamic therapy of cancer. Molecules. 2011;16(5): 4140–64.
- 28. Peng Q, Warloe T, Berg K, Moan J, Kongshaug M, Giercksky KE, et al. 5-Aminolevulinic acid-based photodynamic therapy. Clinical research and future challenges. Cancer. 1997;79(12): 2282–308. pmid:9191516
- 29. Huzaira M, Rius F, Rajadhyaksha M, Anderson RR, Gonzalez S. Topographic variations in normal skin, as viewed by in vivo reflectance confocal microscopy. J Invest Dermatol. 2001;116(6): 846–52. pmid:11407970
- 30. Sandby-Moller J, Poulsen T, Wulf HC. Epidermal thickness at different body sites: relationship to age, gender, pigmentation, blood content, skin type and smoking habits. Acta Derm Venereol. 2003;83(6): 410–3. pmid:14690333
- 31. Harms F, Stolker RJ, Mik E. Cutaneous respirometry as novel technique to monitor mitochondrial function: a feasibility study in healthy volunteers. PloS one. 2016;11(7): e0159544. pmid:27455073
- 32. Costerus SA, Bettink MW, Tibboel D, de Graaff JC, Mik EG. Mitochondrial oxygen monitoring during surgical repair of congenital diaphragmatic hernia or esophageal atresia: a feasibility study. Front Pediatr. 2020;8: 532. pmid:32984226
- 33. Lewin J, Maconochie I. Capillary refill time in adults. Emerg Med J. 2008;25(6): 325–6. pmid:18499809
- 34. La Via L, Sanfilippo F, Continella C, Triolo T, Messina A, Robba C, et al. Agreement between capillary refill time measured at finger and earlobe sites in different positions: a pilot prospective study on healthy volunteers. BMC Anesthesiol. 2023;23(1): 30. pmid:36653739
- 35. Juzeniene A, Iani V, Moan J. Clearance mechanism of protoporphyrin IX from mouse skin after application of 5-aminolevulinic acid. Photodiagnosis Photodyn Ther. 2013;10(4): 538–45. pmid:24284108
- 36. Di Luca M, Iannella G, Montevecchi F, Magliulo G, De Vito A, Cocuzza S, et al. Use of the transoral robotic surgery to treat patients with recurrent lingual tonsillitis. Int J Med Robot. 2020;16(4): e2106. pmid:32223059
- 37. Ye L, Qian Y, Li Q, Fang S, Yang Z, Tan Y, et al. Serum Romo1 is significantly associated with disease severity in patients with obstructive sleep apnea syndrome? 2018;22(3): 743–8. pmid:29302924
- 38. Di Mauro P, La Mantia I, Cocuzza S, Sciancalepore PI, Rasa D, Maniaci A, et al. Acute Vertigo After COVID-19 vaccination: case series and literature review. Front Med (Lausanne). 2021;8: 790931. pmid:35071270