Abstract
Portable x-ray fluorescent (pXRF) technology provides significant opportunities for rapid, non-destructive data collection in a range of fields of study. However, there are sources of variation and sample assumptions that may influence the data obtained, particularly in animal samples. We used representative species for four taxa (fish, mammals, birds, reptiles) to test the precision of replicate scans, and the impact of sample thickness, sample state, scan location and scan time on data obtained from a pXRF. We detected some significant differences in concentration data due to sample state, scanning time and scanning location for all taxa. Infinite thickness assumptions were met for fish, reptile and mammal representatives at all body locations. Infinite thickness was not met for feathers. Scan time results found in most cases the 40, 60 and 80 second beam scan times were equivalent but significantly different to 20 second beam scan times. Concentration data across replicate scans were highly correlated. The opportunities for the use of pXRF in biological studies are wide-ranging. These findings highlight the considerations required when scanning biological samples to ensure the required data are suitably collected and standardised while reducing radiation exposure to live animals.
Citation: Brandis KJ, Francis RJ, Zawada KJA, Hasselerharm CD, Ramp D (2024) Advancing the application of pXRF for animal samples. PLoS ONE 19(12): e0297830. https://doi.org/10.1371/journal.pone.0297830
Editor: Dawid Surmik, University of Silesia, POLAND
Received: January 14, 2024; Accepted: August 15, 2024; Published: December 5, 2024
Copyright: © 2024 Brandis et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the manuscript and its Supporting Information files.
Funding: The author(s) received no specific funding for this work.
Competing interests: The authors have declared that no competing interests exist.
Introduction
Elemental and isotopic signature analyses are routine in the biological and environmental sciences, being used as indicators of diet [1,2], ecotoxicology [3], pollution [4], soil sciences [5] and animal movement studies [6,7]. Current analytical techniques include stable isotope analysis (SIA), inductively coupled plasma mass spectrometry (ICP-S), atomic absorption spectroscopy (AAS), and neutron activation (NAA) among others [8]. However, many of these techniques are destructive, time consuming, and expensive, precluding their use in the field, or on live organisms. Development of rapid, in situ, inexpensive and non-destructive sampling techniques would greatly expand the utility of elemental signatures in biological and environmental sciences.
X-ray fluorescence (XRF) is a well-established methodology for measuring the elemental composition of samples [9]. It is a quantitative, non-destructive technique that measures the abundance of an element based on the characteristic emission of secondary x-rays following excitation by a primary x-ray beam [10]. Portable x-ray fluorescence (pXRF) instruments provide opportunities for field-based data collection. Developed initially for use in the field of geology [11], they are also used in a diverse range of fields including archaeology [12–14], art history [15,16], forensics [17,18] and food sciences [19,20] among others [21–23].
Data obtained from XRF is also used for a range of applied biological questions including the detection of in vivo disease for assessment in humans [24,25], toxicology in humans [26–28] and wildlife [29,30], and geographic provenance for wildlife [7,31]. However, it’s use in animal studies, has been limited relative to the opportunities it offers.
The portability, non-destructive and rapid multi-variable data collection offers significant opportunities in the field of animal sciences. However, due to its initial development for use in geology there are assumptions about sample characteristics that are not necessarily met by biological, and other non-geological samples. This has potential implications for the way in which samples should be processed and scanned, how raw data is processed by pXRF on-board algorithms, and the resulting data provided to the user.
These assumptions include the thickness and density of the sample, referred to as ‘infinite thickness’, i.e., the sample is of sufficient thickness and density that all x-rays are contained within the sample and do not pass through it [32,33]. It has been recognized that data acquired from samples that are thin, and do not meet infinite thickness need to be corrected [33]. The thickness required to meet this assumption varies with the density of the material being analysed [34], which is challenging to accurately determine in living samples.
Moisture content is another variable that can impact on the results returned by pXRF [35,36]. Water absorbs the characteristic x-rays from the elements and causes the primary radiation from the excitation sources to scatter. This results in a decrease in the intensity of characteristic x-rays and an increase in the intensity of scattered x-rays in a fluorescence spectrum [37]. Higher moisture content in soils has been shown to impact data resulting in lower elemental concentrations [35]. Moisture content of biological samples is highly varied and dependant on sample state, and in living samples moisture content is very difficult to determine.
The length of time a sample is exposed to x-rays can impact on the data obtained. Scanning times may affect the ability to detect low-concentration or low atomic weight elements, where longer scan times improve the signal-to-noise ratio [38]. However, in a biological context, there may be a trade-off between detecting elements, and exposing a live organism to excessive radiation. As such, determining whether elemental signatures significantly change in biological samples as a function of scanning time is a key consideration to optimise data quality and organism welfare.
Further, the location of the scan on the sample can also influence results. The partitioning of elements in biological samples may occur due to tissue type, metabolic processes [39], age, and sex [40]. Studies by Nganvongpanit et al. (2016) found different elemental concentrations for different bones within the same individual while Buddhachat et al., (2016) found differences between tissue types with keratinous tissues (hair, nail, skin), being different to bone.
The use of portable X-ray fluorescence (pXRF) as a non-destructive technique for elemental analysis of biological samples offers significant opportunities in the field of biological and environmental sciences. However, when planning a sampling design for biological samples, there are a number of potential sources of variation that need to be accounted for to ensure data are comparable and research questions are answerable. This paper aimed to explore the application of pXRF for elemental analysis of biological samples and to test the major sources of variation across four representative taxa, namely infinite thickness, sample state (dried/thawed), scanning time, and scanning location on the sample. The findings of this study provide insights for future studies and will contribute to the development of standardised protocols for pXRF analysis of biological samples.
Materials and methods
Sampling design
We chose species representing four taxa commonly studied in biological research: reptiles, mammals, birds and fish. Representative species for each taxa were chosen based upon accessibility to sufficient specimens, with each species represented by ten samples.
Reptiles were represented by the shingleback lizard (Tiliqua rugosa) and were sourced as whole or gutted carcasses from Taronga Conservation Society, Macquarie University and Murdoch University. Mammals were represented by the European rabbit (Oryctolagus cuniculus) and sourced from a pet food supplier. Fish were represented by Eastern school whiting (Sillago flindersi) sourced from the Sydney Fish Markets, Australia. Birds were represented by Australian maned duck (Chenonetta jubata), and moulted flight feathers were collected from wetland sites. All taxa except the duck feathers were stored frozen prior to scanning. Each of the taxa were used to test each of the sources of variation.
pXRF data collection
An Olympus Vanta M-Series portable x-ray fluorescence (pXRF) instrument (4-watt X-ray tube with tungsten (W) anode, 8-50keV, silicon drift detector), with three beam energies (10, 40 and 50keV) was used to scan all specimens. Where size permitted, specimens were scanned within the Olympus workstation [41]. Samples were scanned using the GeoChem3 method which uses a fundamental parameters algorithm [42] that automatically corrects for inter-element effects [41]. The instrument was factory calibrated by Olympus and calibration checks were performed throughout the sampling process using the onboard calibration option. The Vanta pXRF provides two output data types; raw beam spectra containing information across 2048 keV bands, and elemental concentrations as a percentage for 42 elements calculated via Olympus’ on-board algorithms.
Reptile, mammal, and fish specimens were scanned in both thawed and dried states, feathers were scanned in their natural state. All specimens were scanned at 20, 40, 60, and 80s/beam with and without silica backing at multiple locations (Fig 1) and states (Fig 2) with 2 replicate scans. The silica dioxide block backing consisted of 30 mm diameter x 25 mm solid cylinder. Prior to scanning, specimens were defrosted at room temperature for ~12 hours and scanned thawed. Specimens were then oven dried (60°C for 72 hours) and re-scanned.
pXRF data analyses
Data from the Vanta were exported as JSON files and processed in R [43] to convert them to compiled csv files for analysis. Files were first read into R using the jsonlite [44] package and relevant data extracted into a dataframe using the tidyverse [45] package. Concentration and raw beam spectra data were extracted from the JSON data and processed using the xrftools [46] package. Spectra processing included associating known characteristic fluorescence energies for elements to the correct spectra energy range, baseline measurement and reduction, and applying a gaussian smoothing filter.
To ensure that elements analysed were present in the samples we checked for diagnostic peaks in the beam spectra data using 80s scans for each species group (thawed state). We excluded any elements that did not match their Kɑ1 and Kß2 peaks [47]. This approach allowed us to remove all non-biologically relevant elements. Eighty second scan data, the longest scan time in this study, were chosen as providing the greatest possibility of detecting the element if present. Elements below the limits of detection were not included in analyses.
To test whether infinite thickness was being met we inspected the beam spectra data to analyse the dispersion of the characteristic lines of the X-ray tube, in this case, the L line for tungsten (W). Where characteristics lines were the same for samples scanned with and without backing, we determined that infinite thickness had been met.
Sample state, scanning time, and scan-location were all tested using a fitted a median quantile regression for each scan location for each species using the concentration data (20, 40, 60 and 80s/beam), and were split into an overall difference test across all elements and a per-element analysis to identify specific element differences. Median quantile regression was chosen as it is more robust than standard least-squares linear regression to skew and kurtosis in the residuals [48]. In cases with multiple response categories such as scanning location or scanning time, pair-wise models were run to, for example, compare leg to tail, leg to head, head to tail, etc. Per-element analyses followed the median quantile approach described above. Overall differences were tested using multi-response generalised linear models [49], or manyglm’s. Manyglm’s allow a model to be specified with multiple response variables (in this case the concentration of each element in a sample) and to calculate an overall effect of an explanatory variable such as tail vs head scanning location. This approach examines all elemental differences simultaneously, and provides overall statistics, including an overall p.value for the effect of the explanatory variable. Unfortunately, no median quantile version of a manyglm is available at present, meaning that these models rely on the assumptions of linear regression. Despite this, they are still likely more robust than typical distance-based approaches [49].
We also tested for correlation between replicate scans to determine the precision of the pXRF when working with biological samples, using Spearman’s correlation coefficient.
Results
We excluded 22 elements from our analyses (Y, Nb, Ag, In, Sb, Te, La, Ta, W, Pt, Au, Pb, Bi, Si, V, Cr, Co, Ce, Ne, Pd, U and Th) due to absences in their Kɑ1 and/or Kß2 peaks.
Infinite thickness assumptions were met for thawed and dried states for fish, rabbits and lizards using concentration data (Fig 3). Infinite thickness was not met for feathers using either concentration and beam spectra data (Fig 3).
Overall, we detected a mix of significant (p<0.05) and non-significant (p>0.05) differences in concentration data due to sample state (Fig 3 and S1 Table), scan time (Fig 3 and S2 Table) and scan location for all taxa (Fig 3 and S3 Table).
All three taxa (reptiles, fish, and mammals) tested for differences between dried and thawed sample states found significant differences in the concentration data overall, with multiple per-element differences identified (Fig 3 and S1 Table).
Scanning time had a significant effect on overall detected elemental concentrations for all taxa when comparing the 20 second beam time to the 40, 60 and 80 second beam times. (Fig 3). All three taxa tested for differences between scan locations revealed some significant differences in overall elemental concentration data amongst differing scan locations (Fig 3).
Overall device precision was very high, with a Spearman’s correlation coefficient of 0.999 when comparing replicate scans). There was variation in the correlation of replicate scans across elements, with heavier elements less correlated than lighter elements (S4 Table).
Discussion
In this study we investigated the application of pXRF for sampling biological samples, focusing on the effects of sample thickness, sample state, scanning time, and scan location on elemental concentration data. Our results found that sample state, and scan location resulted in the most significant differences between element concentrations. Infinite thickness assumptions were met for most tests regardless of sample state, excluding feather samples. Scan time results found in most cases the 40, 60 and 80 second beam times were equivalent.
These findings are consistent with previous studies that reported the impacts of sample moisture [35,50], and sample thickness [34,35] on pXRF data collected from soil samples. Extended scan times were not found to result in significant data gains, which is supported by findings by Williams, Taylor [51], however is contrary to findings by Zhang, Specht [38], which found extended (5 minute) scan times reduced variability in results when scanning bone through soft tissue. Extending scan times on live specimens increases radiation exposure which can result in health impacts [52]. Estevam and Appoloni [24] calculated that a 50 second scan using an x-ray source of 13 and 17 keV resulted in an exposure of 3 mSV.
Based on the results of this study and considering animal care and ethics we would recommend when scanning live specimens that scan times are kept to a minimum while still ensuring adequate data is obtained, our study suggests that 40 s/beam is sufficient to achieve this for most elements (Fig 3). We would also recommend scanning a part of the body that is of sufficient thickness to meet infinite thickness assumptions, but away from key organs to limit the impact of radiation exposure, and to scan with a standardised and consistent backing behind the specimen whenever possible. For the Olympus Vanta this is the provided silicon dioxide block but any other inert, elementally simple material should suffice. This study found that on thawed specimens (akin to live organisms with regards to body thickness and moisture) the majority of scan locations met infinite thickness requirements (Fig 3). However, noting that different scan locations on the specimen may results in different results (Fig 3). This is an important consideration if wanting standardised data between specimens. To ensure consistency the same location should always be scanned. Lastly, noting that we found significant differences in data due the state (thawed or dried) of the sample.
There are some limitations of this study that should be considered when translating our results. Firstly, we only tested a limited number of biological samples from a small set of taxa. Our results may not be generalizable to other types of biological samples but are intended as a guide to the impact different sample characteristics, and sampling techniques may have on results. Secondly, we used a single pXRF instrument with a specific configuration and settings. Different instruments or settings may produce different results [53], however the broad effects demonstrated here should hold as the sources of variation are extrinsic to the instrument. Finally, we did not evaluate the long-term stability or repeatability of pXRF measurements for biological samples [12]. Future research should address these issues by testing more diverse biological samples and elements, comparing different pXRF instruments and settings, and assessing the quality control and assurance procedures for pXRF analysis.
This study demonstrates that pXRF can be a useful tool for biological research if sample characteristics and sample design are cognisant of the assumptions of the pXRF device, and differences within and between samples as highlighted in this study. The advantages of pXRF over conventional analytical techniques include its portability, non-destructiveness, speed, and capability to measure many elements simultaneously. These features make pXRF an attractive option for biological studies that require in situ or large-scale analysis of elemental signatures in various types of samples, such as feathers, hair, bones, plants, soils, etc. However, our study also highlights the considerations required when sampling biological samples using pXRF and the potential impact on results obtained, which include where to scan, how long to scan and how to prepare the sample.
Supporting information
S1 Table. Sample state test results.
Significant (p<0.05) results of sample state testing.
https://doi.org/10.1371/journal.pone.0297830.s001
(CSV)
S2 Table. Scan time test results.
Significant (P<0.05) results of scan time testing.
https://doi.org/10.1371/journal.pone.0297830.s002
(CSV)
S3 Table. Scan location test results.
Significant (p<0.05) results of location test results.
https://doi.org/10.1371/journal.pone.0297830.s003
(CSV)
S4 Table. Spearman rank results.
Spearman correlation co-efficients for device precision.
https://doi.org/10.1371/journal.pone.0297830.s004
(CSV)
Acknowledgments
B. Jackson, Murdoch University, WA. P. Meagher, Taronga Conservation Society, D. Harasti, NSW Department of Planning and Environment, The Reptile Lab, Macquarie University.
References
- 1. Hobson KA, Clark, R.G. Assessing avian diets using stable isotopes I: Turnover of 13C in tissues. The Condor. 1992;94(1):181–8.
- 2. Pearson SH, Avery HW, Kilham SS, Velinsky DJ, Spotila JR. Stable isotopes of C and N reveal habitat dependent dietary overlap between native and introduced turtles Pseudemys rubriventris and Trachemys scripta. PLoS One. 2013;8(5):e62891. Epub 2013/05/16. pmid:23675437; PubMed Central PMCID: PMC3652855.
- 3. Gashkina NA. Essential elements in the organs and tissues of fish depending on the freshwater toxicity and physiological state. Geochemistry International. 2017;55(10):927–34.
- 4. Marcussen H, Dalsgaard A, Holm PE. Content, distribution and fate of 33 elements in sediments of rivers receiving wastewater in Hanoi, Vietnam. Environ Pollut. 2008;155(1):41–51. Epub 2008/01/01. pmid:18164523.
- 5. Mancini M, Weindorf DC, Chakraborty S, Silva SHG, dos Santos Teixeira AF, Guilherme LRG, et al. Tracing tropical soil parent material analysis via portable X-ray fluorescence (pXRF) spectrometry in Brazilian Cerrado. Geoderma. 2019;337:718–28.
- 6. Hobson KA. Tracing origins and migration of wildlife using stable isotopes: a review. Oecologia. 1999;120:314–26. pmid:28308009
- 7. Brandis KJ, Mazumder D, Gadd P, Ji B, Kingsford RT, Ramp D. Using feathers to map continental-scale movements of waterbirds and wetland importance. Conservation Letters. 2021;e12798(e12798).
- 8. Helaluddin ABM, Khalid RS, Alaama M, Abbas SA. Main Analytical Techniques Used for Elemental Analysis in Various Matrices. Tropical Journal of Pharmaceutical Research. 2016;15(2).
- 9.
Beckhoff B, Kanngießer B, Langhoff N, Wedell R, Wolff H. Handbook of Practical X-Ray Fluorescence Analysis: Springer Berlin Heidelberg; 2007.
- 10.
Gates WP. X-ray Absorption Spectroscopy. In: Bergaya F, Theng BKG, Lagaly G, editors. Developments in Clay Science. 1: Elsevier; 2006. p. 789–864.
- 11. Lemière B. A review of pXRF (field portable X-ray fluorescence) applications for applied geochemistry. Journal of Geochemical Exploration. 2018;188:350–63.
- 12. Newlander K, Goodale N, Jones GT, Bailey DG. Empirical study of the effect of count time on the precision and accuracy of pXRF data. Journal of Archaeological Science: Reports. 2015;3:534–48.
- 13. Mauran G, Lebon M, Détroit F, Caron B, Nankela A, Pleurdeau D, et al. First in situ pXRF analyses of rock paintings in Erongo, Namibia: results, current limits, and prospects. Archaeological and Anthropological Sciences. 2019;11(8):4123–45.
- 14.
Liritzism I, Zacharias N. Portable XRF of Archaeological Artifacts: Current Research, Potentials and Limitations. In: Shackley MS, editor. X-Ray Fluorescence Spectrometry (XRF) in Geoarchaeology. London: Springer; 2011.
- 15. Lopez NF. History through the Elemental Anlaysis of Materials and pXRF. APT Bulletin: The Journal of Preservation Technology. 2017;48(4):13–8.
- 16. Molari R, Appoloni CR. Pigment analysis in four paintings by Vincent van Gogh by portable X-ray fluorescence (pXRF). Radiation Physics and Chemistry. 2021;181.
- 17. Kobylarz D, Michalska A, Jurowski K. Field portable X-ray fluorescence (FP-XRF) as powerful, rapid, non-destructive and ‘white analytical tool’ for forensic sciences—State of the art. TrAC Trends in Analytical Chemistry. 2023;169.
- 18. Pringle JK, Jeffery AJ, Ruffell A, Stimpson IG, Pirrie D, Bergslien E, et al. The use of portable XRF as a forensic geoscience non-destructive trace evidence tool for environmental and criminal investigations. Forensic Sci Int. 2022;332:111175. Epub 2022/01/14. pmid:35026699.
- 19. Frydrych A, Jurowski K. Portable X-ray fluorescence (pXRF) as a powerful and trending analytical tool for in situ food samples analysis: A comprehensive review of application—State of the art. TrAC Trends in Analytical Chemistry. 2023;166.
- 20. Malo N, Mazumder D, Crawford J, Gadd P, Gopi K, Saintilan N, et al. Evaluating the Application of Portable Handheld X-ray Fluorescence (XRF) Scanner for Determining Seafood Provenance: A Case Study on Penaeus monodon. Foods. 2023;12(15). Epub 2023/08/12. pmid:37569144; PubMed Central PMCID: PMC10417198.
- 21. Hou X, He Y, Jones BT. Recent Advances in Portable X‐Ray Fluorescence Spectrometry. Applied Spectroscopy Reviews. 2004;39(1):1–25.
- 22. Jurowski K. The toxicological assessment of hazardous elements (Pb, Cd and Hg) in low-cost jewelry for adults from Chinese E-commerce platforms: In situ analysis by portable X-ray fluorescence measurement. J Hazard Mater. 2023;460:132167. Epub 2023/08/24. pmid:37619281.
- 23. Rouillon M, Taylor MP. Can field portable X-ray fluorescence (pXRF) produce high quality data for application in environmental contamination research? Environ Pollut. 2016;214:255–64. Epub 2016/04/22. pmid:27100216.
- 24. Estevam M, Appoloni CR. Use of portable x-ray fluorescence (pxrf) in vivo as an alternative technique for the assessment of iron levels in patients with thalassemia and hemochromatosis. Health Physics Society. 2013;104(2):132–8. pmid:23274815
- 25. Todd AC, Chettle DR. In Vivo X-Ray Fluorescence of Lead in Bone: Review and Current Issues. Environmental Health Perspectives. 1994;102(2):172–7. pmid:8033846
- 26. McInver DJ, VanLeeuwen JA, Knafla AL, Campbell JA, Alexander KM, Gherase MR, et al. Evaluation of a novel portable x-ray fluorescence screening tool for detection of arsenic exposure. Physiological Measurement. 2015;36:2443–59. pmid:26536141
- 27. Specht AJ, Parish CN, Wallens EK, Watson RT, Nie LH, Weisskopf MG. Feasibility of a portable X-ray fluorescence device for bone lead measurements of condor bones. Sci Total Environ. 2018;615:398–403. Epub 2017/10/11. pmid:28988075; PubMed Central PMCID: PMC5688005.
- 28. Specht AJ, Lin Y, Weisskopf M, Yan C, Hu H, Xu J, et al. XRF-measured bone lead (Pb) as a biomarker for Pb exposure and toxicity among children diagnosed with Pb poisoning. Biomarkers. 2016;21(4):347–52. pmid:26856822
- 29. Hampton JO, Specht AJ, Pay JM, Pokras MA, Bengsen AJ. Portable X-ray fluorescence for bone lead measurements of Australian eagles. Sci Total Environ. 2021;789:147998. Epub 2021/05/30. pmid:34051503.
- 30. Nzabanita D, Hampton JO, Toop SD, Bengsen AJ, Specht AJ, Flesch JS, et al. Expanding the use of portable XRF to monitor lead exposure in an Australian duck species two decades after a ban on lead shot. Sci Total Environ. 2023;869:161803. Epub 2023/01/29. pmid:36708833.
- 31. Buddhachat K, Brown JL, Thitaram C, Klinhom S, Nganvongpanit K. Distinguishing real from fake ivory products by elemental analyses: A Bayesian hybrid classification method. Forensic Sci Int. 2017;272:142–9. Epub 2017/02/06. pmid:28157639.
- 32. Kieser R, Mulligan TJ. Prediction of Mass Absorption Coefficients from Inelastically Scattered X-Radiation for Specimens of Less than ‘Infinite Thickness’. X-Ray Spectrometry. 1979;8(1):164–8.
- 33. Sitko R. Quantitative X-ray fluorescence analysis of samples of less than ‘infinite thickness’: Difficulties and possibilities. Spectrochimica Acta Part B: Atomic Spectroscopy. 2009;64(11–12):1161–72.
- 34. Liu H, Lu C, Zhou Z, Huang F, Hu X. Specimen Variation Effects on XRF Analysis by the Monte Carlo Method: Thicknesses, Densities and Particle Sizes. Journal of Applied Mathematics and Physics. 2018;06(04):628–39.
- 35. Padilla JT, Hormes J, Magdi Selim H. Use of portable XRF: Effect of thickness and antecedent moisture of soils on measured concentration of trace elements. Geoderma. 2019;337:143–9.
- 36. de Santana FB, de Giuseppe LO, de Souza AM, Poppi RJ. Removing the moisture effect in soil organic matter determination using NIR spectroscopy and PLSR with external parameter orthogonalization. Microchemical Journal. 2019;145:1094–101.
- 37. Ge L, Lai W, Lin Y. Influence of and correction for moisture in rocks, soils and sediments onin situ XRF analysis. X-Ray Spectrometry. 2005;34(1):28–34.
- 38. Zhang X, Specht AJ, Wells E, Weisskopf MG, Weuve J, Nie LH. Evaluation of a portable XRF device for in vivo quantification of lead in bone among a US population. Sci Total Environ. 2021;753:142351. Epub 2020/11/20. pmid:33207470; PubMed Central PMCID: PMC7677595.
- 39. Tomlinson DJ, Mulling CH, Fakler TM. Invited review: Formation of keratins in the bovine claw: Roles of hormones, minerals and vitamins in functional claw integrity. Journal of Dairy Science. 2004;87:797–809. pmid:15259213
- 40.
Underwood EJ. Trace Elements in Human and Animal Nutrition. 4th ed. New York, USA: Academic Press; 1977.
- 41.
Olympus. Vanta Family X-Ray Fluorescence Analyzer User’s Manual. United States of America: Olympus Scientific Solutions Americas; 2020 April 2020.
- 42. Afonin VP, Finkelshtein AL, Borkhodoev VJ, Gunicheva TN. X-ray fluorescence analysis of rocks by the fundamental parameter method. X-Ray Spectrometry. 1992;21(2):69–75.
- 43.
R Core Team. R: A language and environment for statistical computing. R Foundation for Statistical Computing. Vienna, Austria. ISBN 3-900051-07-0, URL http://www.R-project.org.: R Foundation for Statistical Computing.; 2023.
- 44. Ooms J, Lang DT, Hilaiel L. jsonlite: A simple and robust JSON parser and generator for R https://jeroen.r-universe.dev/jsonlite https://arxiv.org/abs/1403.2805. 2023.
- 45. Wickham H. tidyverse: easily install and load the ’tidyverse’. https://tidyverse.tidyverse.org. 2023.
- 46. Dunnington D. xrftools: XRF Tools for R. https://github.com/paleolimbot/xrftools. 2023.
- 47.
Thomson A, Attwoord D, Gullikson E, Howells M, Kim K-J, Kirz J, et al. X-Ray Data Booklet. 3rd ed. California: Lawrence Berkeley National Laboratory; 2009.
- 48.
Koenker R. Quantile Regression: Cambridge University Press; 2005.
- 49. Wang Y, Naumann U, Wright ST, Warton DI. mvabund–an R package for model‐based analysis of multivariate abundance data. Methods in Ecology and Evolution. 2012;3(3):471–4.
- 50.
Nuchdang S, Niyomsat T, Pitiphathrarbun B, Leelanupat O, Rattanaphra D. Effect of grain size and moisture content on major and minor elements concentrations using portable X-ray fluorescence. Siam Physics Congress 2018 (SPC2018) A Creative Path to Sustainable Innovation; 21–13 May 2018; Pitsanulok, Thailand: Journal of Physics: Conference Series; 2018.
- 51. Williams R, Taylor G, Orr C. pXRF method development for elemental analysis of archaeological soil. Archaeometry. 2020;62(6):1145–63.
- 52. Preston RJ, Boice JD Jr, Brill AB, Chakraborty R, Conolly R, Hoffman FO, et al. Uncertainties in estimating health risks associated with exposure to ionising radiation. J Radiol Prot. 2013;33(3):573–88. Epub 2013/06/28. pmid:23803503.
- 53. Goodale N, Bailey DG, Jones GT, Prescott C, Scholz E, Stagliano N, et al. pXRF: a study of inter-instrument performance. Journal of Archaeological Science. 2012;39(4):875–83.