Due to limited motor capabilities, people with upper limb disabilities have trouble utilizing a typical mouse while operating a computer. Different wearable Assistive Mouse Controllers (AMCs) have been developed to overcome their challenges. However, these people may not be able to realize the importance, ease of use, and social approval of these AMCs due to their fear of new technology, lack of confidence, and lack of ingenuity. These may negatively affect their attitude and intention toward accepting AMCs for equitable human-computer interaction. This study presents the development of a sensor-based head-mounted AMC, followed by an empirical analysis of its acceptance using the Technology Acceptance Model (TAM) from the socioeconomic perspective of Bangladesh. In a similar vein, we examined the effects of three additional psychological constructs—technology anxiety, confidence, and innovation, on its acceptance along with the original components of the TAM. A total of 150 individuals with stroke-induced upper limb disability participated in an online survey, and their responses were analyzed using confirmatory factor analysis and structural equation modeling, following the general least square method. Analysis revealed, about 96.44% of the participants had positive attitude towards the AMC, and almost 88.56% of them had positive intentions to accept it. Furthermore, about 68.61% of them expressed signs of anxiety, 96.35% were confident, and 94.16% of them had an innovative mindset in terms of device usage. The findings imply that individuals with an innovative mentality are more capable of comprehending the practical implications of a new technology than those without one. It is also feasible to reduce technological anxiety and boost a user’s confidence while using an AMC by combining an innovative mentality with straightforward device interaction techniques. Additionally, peer encouragement and motivation can significantly enhance their positive attitude towards accepting the AMC for facilitating their interaction with a computer.
Citation: Kabir MR, Mahmud H, Hasan MK (2023) Acceptability of a head-mounted assistive mouse controller for people with upper limb disability: An empirical study using the technology acceptance model. PLoS ONE 18(10): e0293608. https://doi.org/10.1371/journal.pone.0293608
Editor: Alejandro Vega-Muñoz, Universidad Central de Chile, CHILE
Received: May 26, 2023; Accepted: October 16, 2023; Published: October 31, 2023
Copyright: © 2023 Kabir et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: The responses to the survey questionnaire are available from the Zenodo database (DOI: https://doi.org/10.5281/zenodo.8320738).
Funding: This work was supported by the Research Seed Grant (RSG) received from the department of Research Extension Advisory Services and Publications (REASP), Islamic University of Technology (IUT) under the grant no.: REASP/IUT-RSG/2021/OL/07/012. The grant was received by Dr. Md. Kamrul Hasan. URL: https://www.iutoic-dhaka.edu/research/research-extension-advisory-services-and-publications The funders did not play any role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Competing interests: The authors have declared that no competing interests exist.
Introduction
Recent technological advancements have increased our dependency on computers for any interaction as simple as “checking today’s date” to a task as complex as “writing a computer program” [1]. Healthy people, due to their physical capability, can move the cursor on the computer screen and actuate mouse clicks with the help of a generic computer mouse. However, the scenario is quite different for people with disabilities of the upper limb, caused due to neurological disorders [2–5], accidents [6], or birth defects [7]. Compared to healthy individuals, people with upper limb disability can perform only a limited number of motor activities with their upper limbs, otherwise known as residual capabilities [8]. As a result, their participation in different motor activities is restricted, making them dependent on special devices, otherwise known as Assistive Technologies (ATs) [9]. Since a generic computer mouse is hand-held, such people require different kinds of ATs to facilitate alternative input modalities for interacting with a computer [9]. Hence, any AT that functions as an alternative to a generic computer mouse or a similar pointing device, allowing a disabled individual to interact with a computer, may be termed an Assistive Mouse Controller (AMC).
Stroke is the major cause behind upper limb disability in the socioeconomic context of Bangladesh [10–12]. Unfortunately, there is no comprehensive system to recognize the requirements of AMCs for the disabled community, let alone register their usage [13–16]. Moreover, since the majority of these people live below the poverty line [17], they are unable to afford [18] many of the existing state-of-the-art AMCs [19–35]. Consequently, they are not only falling behind in economically empowering themselves through activities involving a computer but also in contributing to the national economy of Bangladesh [36]. This suggests that there is a scope for developing an AMC for economically empowering the upper limb disabled community of Bangladesh. Considering their lack of experience in using AMC technology [16, 18], it is also imperative to study the probable influence of their perception of its usefulness, ease of use, social approval, etc., on its acceptance [37] from the socioeconomic perspective of Bangladesh. In a similar vein, it is very natural for them to exhibit signs of anxiety about the ergonomics, complexity of interaction techniques, hygiene issues, etc., associated with the technology [37–39]. Moreover, they might also feel less—confident [37, 40–42], innovative, enthusiastic, etc. [37, 43–45], while using the AMC technology. Moreover, analysis of these psychological constructs may provide insights into whether to add new or modify existing features of an AMC to favor its acceptance in the socioeconomic context of Bangladesh. However, a theoretical understanding of such influence on newly developed AMC technologies is inadequate in the literature [37, 46].
To date, researchers have explored the feasibility of various wearable sensors in the design and development of AMCs for people with upper limb disability while leveraging their residual motor capabilities [8, 19–34]. Among these capabilities, head movement is a natural, effective, and one of the most common modalities for moving a cursor [19–22]. Other alternatives include but are not limited to—tongue muscles movement [23], eye gaze tracking using eye-trackers, webcams, or other imaging sensors [24–26], Electromyography (EMG) [27, 28], Electrooculogram (EOG) [29–34], Brain-Computer Interfaces (BCI) [35], etc. However, to the best of our knowledge, an AMC for the upper limb disabled community from the socioeconomic perspective of Bangladesh has not yet been developed [13–16].
The Technology Acceptance Model (TAM) [40, 41] has been widely used by researchers [37–39, 43, 44, 46–58] for analyzing the influence of various psychological constructs, for example—Perceived Usefulness (PU), Perceived Ease of Use (PEU), Subjective Norm (SN), Attitude Towards Usage (ATU), Behavioral Intention (BI), etc., on the user’s perception and intention to use various ATs in general. It is also evident from the literature that the constructs external to the TAM, namely—Technology Anxiety (TA) (perceived fear of a new technology) [38, 39], Perceived Behavioral Control (PBC) (perceived confidence of carrying out a task with a technology) [40–42], and Personal Innovativeness (PI) (portraying enthusiasm, curiosity, innovation, etc., while using a new technology) [43–45], also play a crucial role behind the acceptability of different ATs [37, 47, 48, 59]. However, to the best of our knowledge, the influence of these external constructs along with the internal ones of the TAM on the acceptance of AMCs by individuals with upper limb disability from the socioeconomic perspective of Bangladesh has not been carried out.
From the perspectives mentioned above, in this study, we present the design and development of a functional prototype of a head-mounted sensor-based AMC to facilitate equitable human-computer interaction for individuals with stroke-induced upper limb disability. With motivation from prior studies [19, 20, 22] the proposed AMC utilizes an Inertial Measurement Unit (IMU) to register head motion for moving a mouse cursor on the screen. For registering mouse clicks, on the other hand, we adapted the idea of exploiting cheek muscle twitches from [8]. However, the authors in [8] leveraged flex sensors for registering the cheek muscle twitches, whereas, in our study, we used infrared sensors. The rationale behind doing so stems from the fact that the flex sensors had to be attached to a user’s cheek with the help of adhesives [8]. We perceived that this may significantly reduce the ease of use, comfort, and wearability of the device. Although we were able to overcome these limitations by using infrared sensors, we were faced with new challenges related to fluctuating sensor readings due to—ambient light, varying shapes of cheek muscles, etc. Special design considerations from both hardware and software perspectives were taken into account to address these challenges. Thus, it is safe to say that such an AMC for the upper limb disabled community from the socioeconomic perspective of Bangladesh is the first of its kind. From a similar standpoint, we also examine the influence of the fundamental psychological constructs of the original TAM framework (PU, PEU, SN, ATU, and BI) [39, 40] as well as the three constructs external to it, namely—TA [38, 39], PBC [40–42, 54, 55, 60] and PI [43–45, 56, 61–63], on the users’ perceptions of and intentions to use the proposed AMC for the previously mentioned reasons.
To summarize our contributions to this study—(1) to develop an IMU and infrared sensor-based wearable AMC for people with upper limb disability from the socioeconomic perspective of Bangladesh, and (2) to analyze the impact of different psychological constructs of the TAM framework (PU, PEU, SN, ATU, and BI) [40, 41] along with three external constructs (TA, PBC, and PI) adapted from prior studies [38–45, 49–56, 60–63] on one another (significant or otherwise) on the acceptability of the proposed AMC to people with upper limb disability in a similar vein.
Theoretical background
The Technology Acceptance Model (TAM) [40–42], depicted in Fig 1, has been widely used for analyzing users’ acceptance of different ATs in previous studies [37–39, 43, 44, 47–56]. According to the literature [40–42], the influences of different psychological constructs of the TAM on the users’ acceptance of new technology are defined as follows -
- Perceived Usefulness (PU): “The degree to which a person believes that using a particular system would enhance his or her job performance” [40–42].
- Perceived Ease of Use (PEU): “The degree to which a person believes that using a particular system would be free of effort” [40–42].
- Subjective Norm (SN): “An individual’s perception that most people who are important to him or her think s/he should or should not perform the behavior in question” [40–42].
- Attitude Towards Usage (ATU): “An individual’s positive or negative feelings (evaluative affect) about performing the target behavior” [40–42].
- Behavioral Intention (BI): “A measure of the strength of one’s intention to perform a specified behavior” [40–42].
The analysis of users’ acceptance of technology using the TAM framework typically involves a self-administered, closed-ended, n-point (n = 4, 5, 6 or 7) Likert scale-based survey questionnaire, which is divided into sections that represent different psychological constructs (e.g., PU, PEU, SN, etc.) [39, 42, 55, 64, 65]. Each question corresponding to a particular construct is normally referred to as a measurement item. Based on a theoretical analysis of the possible influence of one construct over another, alternative hypotheses are postulated [42, 49, 66, 67] and later tested (rejected or accepted) during data analysis. In studies related to technology acceptance, involving TAM [38, 39, 49, 50, 52, 66, 67], data analysis typically involves two steps—1) developing a Measurement Model and 2) developing a structural model using Structural Equation Modeling (SEM) [39, 61, 66]. A brief description of these two steps is provided in the subsequent paragraphs.
Measurement model
The measurement model is generally developed through Exploratory Factor Analysis (EFA) or Confirmatory Factor Analysis (CFA) [39, 66, 68–70]. Detailed descriptions of EFA and CFA are beyond the scope of this study, and the reader is requested to refer to the work of Noora Shrestha [70] for better comprehension. However, before either EFA or CFA could be conducted for developing the measurement model, it is necessary to check whether the dataset under consideration is adequate for factor analysis. The adequacy test involves both Bartlett’s test of sphericity and Kaiser-Meyer-Olkin (KMO) measure of sampling adequacy [69, 70]. Bartlett’s test of sphericity is intended to test whether the items in the questionnaire are correlated enough, such that the correlation matrix does not become an identity matrix. This can be verified if the value of p, obtained from this test is less than 0.05 at 95% confidence interval [70]. The KMO measure, on the other hand, is used to determine whether the sample size is large enough for factor analysis. The KMO value ranges between 0 and 1, indicating 4 types of sample size, namely—“adequate” (0.80≤ KMO <1.00), “middling” (0.70≤ KMO <0.79), “mediocre” (0.60≤ KMO <0.69), and “inadequate” (KMO <0.60) [70]. Factor analysis cannot be carried out with inadequate sample size, in which case the sample size must be increased [70]. The measurement model is developed to test the following properties -
- Overall reliability of the questionnaire: Measured using the Cronbach’s Alpha (α) (CA) test, where α > 0.7 is recommended for acceptable reliability [39, 66].
- Internal consistency of the constructs: Generally measured using their respective Composite Reliability (CR) [39, 61, 66, 68, 71], where the typical value of CR should be greater than 0.7 [39, 68]. However, CR>0.6 and CR≤0.7 is also acceptable [66, 71].
- Individual item reliability: Measured using factor loadings (λ), where factors are defined as latent or unobserved variables that affect a particular construct [39, 61, 68, 71, 72]. Only the factors with eigenvalues greater than 1 are considered for analysis [70]. Although the typical value of λ should be greater than 0.7, values between 0.5 and 0.7 are also acceptable [68, 72].
- Convergent Validity (CV) of a construct: An indicator of high correlation between theoretically related items. Alternatively, CV ensures that the items intended for measuring a construct are indeed measuring that construct. For ensuring the CV of a construct, both the CR and the Average Variance Extracted (AVE) of that construct are considered. Previous studies suggest that CR>0.7 and AVE>0.5 combined, are indicators of good convergent validity [39, 70, 71, 73]. However, if AVE<0.5, but CR>0.6, the CV of the construct is still considered to be adequate [71].
- Discriminant Validity (DV) of a construct: Ensures that the items of a particular construct are not measuring a different construct [39, 68]. DV can be tested using the Fornell and Larcker criterion [45], where the squared root of AVE for a construct (usually placed on the diagonal of the construct correlation matrix) is greater than its correlation coefficients with other constructs [38, 45, 61, 66, 68, 71].
Structural model
After a measurement model has been developed, Structural Equation Modeling (SEM) is used to test the hypotheses postulated earlier during the theoretical analysis of the possible influence of one construct over another, relevant to the acceptance of technology [38, 39, 49, 50, 52, 66–68], for developing a structural model. For example, if we consider two constructs, CONS1 and CONS2, where CONS1 is hypothesized to have an influence on CONS2; the influence is represented with an arrow, termed as a path, from CONS1 to CONS2. The standardized β coefficient, otherwise known as the path coefficient, is considered as the magnitude of the influence. This coefficient may be estimated using any one of the following methods—Partial Least Square (PLS) [39, 66], Maximum Likelihood [52, 74, 75], Unweighted Least Squares (ULS) [76–78], and Generalized Least Squares (GLS) [77]. The statistical significance of the path coefficient (β) is determined either through bootstrapping [61, 74, 79], t-tests, or Z-tests [66] to calculate p-values at a significance level of 0.05. Therefore, a hypothesis is accepted, if the z-value is either <−1.96 or >1.96 and p < 0.05, otherwise, it was rejected. After quantitatively investigating all the hypotheses, the results are combined to generate a path model as an outcome of SEM. Although the path model gives an overview of the influences (significant or insignificant) of one construct over another, it is important to investigate the relative fit of the data to the model. For this purpose, many studies have recommended fit indices, namely—the ratio of chi-square to degrees of freedom (χ2/df), the Goodness-of-Fit Index (GFI), Adjusted Goodness-of-Fit Index (AGFI), Comparative Fit Index (CFI), Tucker-Lewis Index (TLI), Normed Fit Index (NFI), and Root-Mean-Square Error of Approximation (RMSEA) [49, 67, 69, 80, 81].
Literature review
Till date, several researchers have leveraged TAM for analyzing how different psychological constructs, under the influence of external variables, affect user’s acceptance of different technologies. Liu et al. [46] tested 7 commercially available wearable ATs for motor function rehabilitation, daily activity assistance, and knee care for the elderly (aged 65 and above). They analyzed 14 perception variables related to device usage [PU, PEU, SN, ATU, TA, ease of maintenance (EOM), weight (WEI), portability (POR), perceived comfort (PCOM), perceived convenience (PCON), appearance (APP), perceived need (PN), perceived cost-effectiveness (PCE), and trust (TRU)] by testing 27 hypotheses. They recruited healthy and educated older adults who did not have much need for ATs in general for their survey. After gathering demographic data via a questionnaire, the participants were informed about the functions, features, and history of the devices. They could use any three of the seven gadgets to complete three tasks with each one, followed by rating their perception of using the gadgets on a 7-point Likert scale. The findings of their study suggest that developers should understand the need of the stakeholders while ensuring simple interaction mechanisms and intuitive and self-explanatory UI. This may significantly increase PEU, device effectiveness, and user satisfaction while reducing the probability of errors. Most importantly, reliable quality and functional stability must be ensured to positively affect the constructs—TRU and PU. Finally, the user base of such devices should be increased to reduce the feeling of shame or shyness about using them. Apart from making proper arrangements for advertising the existence, usage, and benefits of using these devices, mental health counseling sessions can also be arranged for achieving these goals. Liu et al. in another study [57], explored whether and why patients accept a Health Information Technology (HIT) platform and continue to accept it over time. They conducted the study on patients with type-2 diabetes and hypertension using a patient-focused, touchscreen tablet-based system over a 24-week implementation period. They were motivated by the fact that previous studies only considered conventional constructs while analyzing acceptance of HIT platforms, whereas many nonconventional and inferred constructs might influence their acceptance as well. Moreover, the prior studies mostly explored smartphone-based applications and telemedicine, and hence, the findings of those studies might not apply to HIT systems designed for the self-management of chronic diseases at home. The authors proposed a theoretical model for HIT acceptance by patients with chronic diseases performing self-management at home while additionally considering the psychological constructs—perceived hand function (PHF), perceived visual function (PVF), and perceived space adequacy (PSA), external to the TAM framework. Tsai et al. [39], in addition to the traditional components of TAM, conducted a study with 31 older patients with cardiovascular diseases and 81 older adults in general, to understand the behavioral effects of TA, Perceived Ubiquity (PUB), and Resistance to Change (RC), on the adoption of a wearable cardiac warming system in older adults. Their research findings state that TA has negative effects on PEU and PUB, while PUB affects both PU and PEU of the cardiac warming system. On top of these, PU was found to have an indirect effect on BI through ATU. Felea et al. [66] analyzed the influence of constructs—Perceived Enjoyment (PE), defined as, “the level to which using a specific technology or service is seen as enjoyable”, and Visual Attractiveness (VA), defined as, “an aesthetic product design expressed through shapes, colors, and materials and user interfaces such as device menus and the mobile applications of wearable devices”, on the adoption of wearable technologies among 192 Romanian students using the TAM. Their analysis revealed that apart from the relation between the original constructs of the TAM, VA positively affects PE and ATU, while PE positively affects PU, ATU, and BI when it comes to the adoption of wearable technologies. Ashfaq et al. [49] analyzed external constructs, namely—Perceived Irreplaceability, Perceived Credibility, Compatibility, etc., that might influence elderly diabetic peoples’ intention to continue using digital health wearables through a survey from 223 diabetic patients, aged 60 years and above. The findings of their study revealed that all the constructs mentioned above had a positive influence on the intention to continue using digital health wearables. Lin et al. [38], have developed an instrumented wearable vest for monitoring the quality of posture among elderly people. They identified Technology Anxiety (TA) as a common psychological trait among elderly people when acceptance of new technology is of concern. About 50 elderly people were recruited for their study and leveraging TAM, they analyzed the ATU and BI of their proposed technology under the influence of the psychological constructs—TA, PU, and PEU. Hong et al. [51], Chuah et al. [52] and Kim et al. [67], through a survey involving 276, 226, and 363 participants, respectively, utilized TAM to empirically identify Visibility (VIS), Affective Quality (AQ), Relative Advantage (RA), Mobility (MB), Availability (AV), Subcultural Appeal (SA), Consumer Innovativeness (CI), etc., as potential external constructs that might influence adoption of smartwatches. The results of these studies suggest that the variables AQ and RA influenced PU, while MB and AV influenced PEU, and the variables, CI, SA, and VIS, were found to be significant indicators of ATU and BI of smartwatch adoption. Lunney et al. [50] deployed the TAM for gaining insights into a user’s perception of Wearable Fitness Technologies (WFT) and to analyze the relation between perceived health benefits and the use of WFTs. From their analysis, it may be stated that WFTs that have enhanced PU and PEU, are more likely to instigate increased positive ATU and BI towards their adoption. Apart from these technologies, evidence of studies on the acceptance of industrial upper limb exoskeleton [82, 83] and head-mounted display-based augmented reality [84] can also be found in the literature. A generic finding of these studies suggests that to increase the usage and adoption of ATs, they should be designed from both engineering and user perspectives while ensuring ease of use, comfort, usefulness, reliability, ergonomics, etc.
Prototype development
We have developed a working prototype of the proposed head-mounted AMC, as shown in Fig 2. It mainly consists of three separate entities—1) a transmitter unit, 2) a receiver unit, and 3) a device driver software.
(a) The wearable transmitter unit, for sensor data acquisition and transmission, (b) infrared sensor housing and adjustable mechanism, (c) the receiver unit, for wireless retrieval of sensor data and forwarding those to the device driver software, and (d) the custom device driver software for mapping sensor data to system calls for mouse control.
The physical form factor of the transmitter unit is similar to that of a helmet, hence the AMC is head-mounted. It contains all the sensors, microcontroller, wireless communication module, and power source and is responsible for sensor data acquisition, processing, and wireless data transmission to a PC via the receiver unit. It is important to note that the form factor of the human head is not absolute, rather it varies across humans. Therefore, to ensure the comfort and wearability of the AMC by people with varying head sizes, adjustable head-straps have also been facilitated.
To facilitate mouse-cursor movement, we exploited absolute movements of the head. An Inertial Measurement Unit (IMU), featuring an MPU9250 (a combination of a 3-axis accelerometer, a 3-axis gyroscope, and a 3-axis magnetometer) was used to measure the yaw (horizontal rotation of the head about the z-axis) and the pitch (vertical rotation of the head about the y-axis) angles of head rotation in degrees. These values were then converted to 2D screen coordinates facilitating horizontal and vertical movements of the mouse cursor on the screen, respectively. A user can simply rotate his/her head by only ±15° both horizontally and vertically, and move the cursor about the entire screen. Literature suggests that head movements to this extent are well within the ergonomic range of motion of the human head and are unlikely to cause neck pains, in the long run, [85].
The transmitter unit contains a visor-like mechanism that can be rotated up and down to make it easier for the user to wear the AMC, as shown in Fig 2a. To facilitate left and right mouse-click actuation, we leveraged left and right cheek muscle twitches, respectively. One pair of infrared sensors (transmitter and receiver) per cheek (left and right), as depicted in Fig 2b, were used in this regard. Although the infrared sensor readings are inherently subject to fluctuations due to changes in the ambient lighting conditions, we have compensated for this limitation with the help of a strategically placed mechanical ambient light-blocking shield on the wearable itself as well as through software. Another inherent challenge with actuating mouse clicks in this manner is the variations in cheek shape from person to person, resulting in different patterns of cheek muscle movements. Therefore, to ensure proper actuation of mouse clicks, the infrared sensors are placed on the visor mechanism with vertically adjustable housing which can be slid up and down, as depicted in Fig 2b, allowing 2 degrees of adjustments to fit differently shaped cheek muscles. The receiver unit, as shown in Fig 2c, connects to a PC and is responsible for retrieving data from the transmitter unit, wirelessly. These data are then mapped to appropriate system calls with the help of a device driver with customizable features, as shown in Fig 2d, enabling mouse control.
The yaw and the pitch angles are measured relative to a reference zero point, which is considered as the orientation of the user’s head at the device startup while the user focuses on the screen at its center. Therefore, at startup, the transmitter unit goes through a calibration phase (8−10 seconds), during which the user orients his/her head towards the middle of the screen and holds the position until they hear 3 consecutive beeps. The third beep at the end of the calibration phase indicates that the device has been calibrated, and the user is free to move his/her head or twitch cheek muscles for controlling the mouse. Furthermore, to enhance the user’s experience while interacting with the device, two gesture controls, one for enabling and the other for disabling the mouse functionality of the AMC, have been incorporated. For disabling the mouse, a user has to rotate his/her head down to about 35° and twitch both cheek muscles, after which they can easily interact with their surroundings. During this time, no data will be transmitted to the receiver unit. For enabling the mouse, the user has to rotate his head up to about 35° and twitch both cheek muscles, after which the mouse can be controlled as before.
Hypothesis development and research model
In this section, in addition to the original psychological constructs of the TAM (PU, PEU, ATU, SN, and BI) [42], we discuss the three external constructs, namely—Personal Innovativeness (PI), Technology Anxiety (TA), and Perceived Behavioral Control (PBC), that may influence the acceptance of the proposed AMC technology by people with upper limb disability. Furthermore, we also state our hypotheses regarding how each of the constructs may influence other constructs, thereby, proposing our conceptual framework for validation.
Constructs of the TAM
The primary objective of the TAM is to identify the psychological constructs that determine users’ attitude towards (positive or negative) and intention to accept a particular technology, identifying the direct or indirect influence of the constructs on one another in the process [37–39, 41–44, 47–57, 67]. TAM theorizes a direct positive effect of PU on the constructs ATU and BI [42]. In the context of our study, PU is the perception of a user with an upper limb disability that they will be able to interact with a computer while enhancing their productivity, work efficiency, etc. with the proposed AMC. Prior studies have analyzed similar influences in the adoption of wearable technologies as well [38, 39, 44, 45, 49–52, 67]. On the other hand, PEU of the AMC refers to the degree to which a user perceives that it allows effortless interaction mechanisms, consequently affecting their PU and ATU towards it [8, 38, 40–42, 52]. Furthermore, an easy-to-use technology supposedly should have a greater influence on the confidence (PBC) of using that technology [60]. As evident from the literature [37–39, 42–44, 47–56], SN is a crucial construct for determining user acceptance of any wearable technology. However, to the best of our knowledge, there are insignificant references to the analysis of the effect of SN and ATU on a user’s intention (BI) of using a wearable AMC in the literature [41, 50, 56, 86]. Therefore, we propose the following hypotheses -
- H1: PU has a positive influence on ATU of the wearable AMC.
- H2: PU has a positive influence on BI of the wearable AMC.
- H3: PEU has a positive influence on PU of the wearable AMC.
- H4: PEU has a positive influence on PBC while using the wearable AMC.
- H5: PEU has a positive influence on ATU of the wearable AMC.
- H6: SN has a positive influence on PU of the wearable AMC.
- H7: SN has a positive influence on PEU of the wearable AMC.
- H8: SN has a positive influence on ATU of the wearable AMC.
- H9: SN has a positive influence on a user’s BI of using the wearable AMC.
- H10: ATU has a positive influence on a user’s BI of using the wearable AMC.
Technology Anxiety (TA)
Technology Anxiety (TA) as proposed by Lin et al. [38] and Tsai et al. [39], is the perceived fear involved with any technology. For reasons mentioned earlier, the potential anxiety factors about the proposed AMC could be the device ergonomics, complexity of interaction techniques, hygiene issues, etc. Logically, TA should be negatively correlated with PEU [38, 39]. Therefore, the following hypothesis is stated -
- H11: TA has a negative influence on PEU of the wearable AMC.
Perceived Behavioral Control (PBC)
As reported by previous studies [40–42, 54, 55, 60], the confidence while performing any task, or in other words, Perceived Behavioral Control (PBC), may have a direct or indirect positive impact on the ATU and BI of accepting a technology depending on the context. However, to the best of our knowledge, there are insignificant references to PBC in the context of users’ acceptability of the proposed wearable AMC. Therefore, we state the following hypotheses -
- H12: PBC has a positive influence on ATU of the wearable AMC.
- H13: PBC has a positive influence on a user’s BI of using the wearable AMC.
Personal Innovativeness (PI)
Personal Innovativeness (PI) may be defined as, “the presence of characteristics, such as—willingness, curiosity, search for novelty, creativity, etc. in an individual for adopting a technology” [43–45]. Highly innovative individuals tend to be confident, and enthusiastic, and therefore, require a shorter time to accept a particular technology [43, 61]. Such individuals can realize the potential advantages of adopting a technology, earlier than others, and therefore, their positive ATU and BI towards that technology increase gradually [44, 45, 56, 61]. However, the literature suggests that the effect of PI on different constructs of the TAM in different contexts requires further investigation [62, 63]. In the context of this study, the proposed wireless head-mounted AMC may be considered as a technological innovation for people with upper limb disability in Bangladesh. Therefore, we postulated the following hypotheses -
- H14: PI has a positive influence on PU of the wearable AMC.
- H15: PI has a positive influence on PEU of the wearable AMC.
- H16: PI has a positive influence on PBC while using the wearable AMC.
- H17: PI has a positive influence on ATU of the wearable AMC.
- H18: PI has a positive influence on a user’s BI of using the wearable AMC.
Research model
In this study, 18 hypotheses (H1-H18) have been postulated for verifying the relationship among eight psychological constructs of the Technology Acceptance Model (TAM), namely—Perceived Usefulness (PU), Perceived Ease of Use (PEU), Subjective Norm (SN), Personal Innovativeness (PI), Technology Anxiety (TA), Perceived Behavioral Control (PBC), Attitude Towards Usage (ATU), and Behavioral Intention (BI), concerning the acceptance of the proposed AMC. Out of these 18 hypotheses, 7 of them were conventional, i.e. considered in the original framework of the TAM as well [40–42]. A summary of the postulated hypotheses and a TAM-based research model, specific to the adoption of the proposed AMC, are given in Table 1 and Fig 3, respectively. The validity of these hypotheses will be subsequently analyzed to identify the constructs that are significant in determining users’ acceptability of the proposed AMC from the socioeconomic perspective of Bangladesh.
[PU: Perceived Usefulness, PEU: Perceived Ease of Use, SN: Subjective Norm, PI: Personal Innovativeness, TA: Technology Anxiety, PBC: Perceived Behavioral Control, ATU: Attitude Towards Usage, and BI: Behavioral Intention].
Research methodology
Participants
The target respondents of this survey were individuals who despite having basic computing knowledge fail to interact with a computer due to any form of upper limb disability and are willing to adapt to an alternative modality for human-computer interaction. As mentioned earlier, analysis of the acceptance of technology using the TAM framework involves a self-administered, closed-ended survey questionnaire, which is divided into sections that represent different psychological constructs. However, due to the onset of COVID-19 at the time of this study, it was not possible for us to facilitate first-hand device usage through physical sessions with such individuals, and therefore, the survey had to be conducted online. Consequently, a comprehensive video of device interaction involving real-life users with upper limb disability (recorded prior to COVID-19 with verbal consent from them after the device prototype had been developed) was accommodated. This video helped demonstrate the prospect, usage, and interaction mechanism of the proposed AMC for executing different computing tasks to the respondents of the survey. Although familiarizing the users with the proposed AMC in this manner represents a notable limitation of our study, evidence of such an approach to TAM analysis can be found in the literature as well [87, 88].
The survey questionnaire was circulated only among those respondents, who verbally consented to participate in the survey, via email or social networking sites. In connection to this, a total of 150 individuals with stroke-induced upper limb disability, among which 107 were Male (71.33%, Mean Age: 33.13 ± 5.38 years) and 43 were Female (28.67%, Mean Age: 34.49 ± 4.12 years), participated in the online survey with the help of their caregivers. The survey was conducted between 01 January and 31 May 2022, and the corresponding data were accessed for research purposes between 01 June and 31 August 2022. The authors did not have access to information that could identify participants during or after the survey was conducted. The study was approved by the Department of Research, Extension, Advisory, Services, and Publications (REASP) at the Islamic University of Technology (IUT).
Developing measurement items
In this study, 28 measurement items were considered for developing the construct measures, where few items were adopted and some were adapted from prior studies to suit the context of this study. Some items were newly developed specifically for this study as well. The questionnaire was subdivided into 11 sections, where 8 sections addressed items corresponding to the different psychological constructs (PU, PEU, SN, PI, TA, PBC, ATU, and BI) of the proposed research model, as shown in Fig 3. In 2 of the remaining 3 sections, a brief description of the prospects of the proposed AMC and questions relevant to demographic data (name, age, and gender) were presented. The remaining 1 section was allotted for the video demonstration of how different pointing [72] and typing tasks can be accomplished with the proposed AMC. The organization of the 11 sections of the questionnaire is depicted in Fig 4.
[PU: Perceived Usefulness, PEU: Perceived Ease of Use, SN: Subjective Norm, PI: Personal Innovativeness, TA: Technology Anxiety, PBC: Perceived Behavioral Control, ATU: Attitude Towards Usage, and BI: Behavioral Intention].
It is to be noted from this organization that the items corresponding to the constructs PU, PI, and TA are presented after the device description and before the video demonstration of device interaction. However, the items corresponding to the constructs PEU, PBC, SN, ATU, and BI, are presented after the video demonstration. Such organization of the questionnaire was made with the following objectives in mind -
- (a) To record the respondents’ PI that might affect their ATU later on and to capture their initial thoughts on the constructs, PU and TA, from the device description.
- (b) Since first-hand interaction with the proposed AMC could not be accommodated for the participants of this study, it was necessary that the respondents had a clear understanding of the working mechanism of the AMC for analyzing their acceptance of the technology using the TAM. In connection to this, the video demonstration of device interaction will assist them with the constructs, PEU, PBC, and SN, which in the end, would be reflected on their ATU and BI of accepting the proposed AMC that facilitates human-computer interaction for the people with upper limb disability.
As pointed out by Jonald L. Pimentel [64], Likert scales essentially quantify bipolar opinions (positive or negative) about a particular statement. However, the responses may be biased due to several reasons, e.g., respondents’ tendency to avoid extreme opinions (central tendency bias) [64]. To remove this type of bias, Likert scale items with an even number of options (4-point or 6-point), or in other words, items with no choice of neutrality are generally suggested for greater reliability of the responses [64, 89–91]. In connection to this, a 4-point Likert scale was used to quantify the responses to the psychological constructs of the proposed research model, where the Likert scale representations were as follows—1—Strongly Disagree, 2—Disagree, 3—Agree, and 4—Strongly Agree. The items, corresponding to different psychological constructs considered for this study, are summarized in Table 2.
Before being used for online data collection, the questionnaire was reviewed by a group of 10 reviewers who had prior experience with wearable technology and did not have any upper limb disabilities. Before scrutinizing the comprehensibility and obscurity of the measuring items, they were initially told online about the goal of the study and the survey. They endorsed the questionnaire’s sectional organization and pointed out any slight formatting flaws; these were subsequently corrected, and the questionnaire was approved for data collection.
Data analysis
Before conducting CFA for assessing the reliability and validity of the corresponding measurement model, an adequacy test was performed to verify whether the sample size (n = 150) is suitable for CFA. Structural Equation Modeling (SEM) was then performed for hypotheses (H1-H18) testing and validation in python language with the help of the library, “semopy” [92], following the GLS method [77]. Consequently, a path model was generated summarizing the results of SEM [39, 50, 52, 56, 61, 66–70]. The R2-values of regression analysis were used to quantify the percentage of variance explained by the predictor variables in the proposed research model. Finally, the relative fit of the data to the model was analyzed using different fit indices (χ2/df, GFI, AGFI, CFI, TLI, NFI, RMSEA) [49, 67, 69, 80, 81].
Results
Measurement model
The adequacy test of the sample, considered for this study, was conducted using both Bartlett’s test of sphericity and Kaiser-Meyer-Olkin (KMO) measure of sampling adequacy [69, 70]. The sphericity test (χ2 = 2016.17, p < 0.001) indicated that the inter-construct correlation matrix was not an identity matrix, as shown in Table 5. The KMO value for the sample (KMO = 0.8057) indicated that the sample size was “Adequate” for Confirmatory Factor Analysis (CFA). A summary of the sample adequacy test results is given in Table 3.
The results of the measurement model, obtained using CFA, as shown in Table 4, indicated that the measurement items demonstrated strong psychometric properties. The internal reliability of the items in each of the psychological constructs, measured using Cronbach’s Alpha (CA) [39, 66], ranged between 0.7248 and 0.8969 and the overall reliability of the questionnaire was found to be 0.8801, which indicates “Good” reliability. In simple terms, the items could quantify the constructs accurately. The factor loadings (λ), as a measure of individual item reliability, were obtained using Principal Component Analysis with “varimax” rotation [68, 70]. The values of λ for 50% of the items ranged between 0.5 and 0.7, while the rest were above 0.7, both of which are permissible [39, 49, 61, 68, 69, 71]. In connection with these results, the reliability of the constructs can be ascertained.
The internal consistency of the psychological constructs was measured using Composite Reliability (CR) [39, 61, 66, 68, 71] with values ranging between 0.7293 and 0.8224, which is indicative of “Good” internal consistency. However, for the construct Perceived Behavioral Control (PBC), the value of CR was found to be 0.6821, which is also acceptable [66, 71]. The validity of the measurement model was tested using CV [39, 70, 71, 73] and DV [39, 68]. For evaluating the CV, both CR and AVE were considered [39, 70, 71, 73]. Five out of the eight constructs (PU, TA, PBC, PEU, and ATU), considered in this study exhibited “Acceptable” CV with AVE ranging between 0.4384 and 0.5181, and CR ranging between 0.6821 and 0.8224. The remaining three constructs (SN, PI, and BI) had AVE ranging between 0.5110 and 0.6690, and CR ranging between 0.7575 and 0.8109, suggesting “Good” CV. Overall, the model had satisfactory CV. On the other hand, the DV of the constructs was evaluated using the Fornell and Larcker criterion [45]. The DV of the constructs of this study along with the Mean and the Standard Deviation (SD) are summarized in Table 5. It can be seen from this table that for each of the constructs, the corresponding squared root of AVE is greater than all the corresponding inter-construct correlations. Therefore, it can be stated that the model demonstrates satisfactory DV.
Structural model
From the results of SEM, as shown in Table 6, it was observed that 6 (85.71%) out of the 7 conventional hypotheses and 13 (72.22%) out of the total 18 hypotheses were supported. According to the order in which the measurement items were presented in the online survey questionnaire, as shown in Fig 4, about 94.16% of the participants (n = 150) claimed to have an innovative mindset (PI), and about 94.71% of them could perceive the usefulness (PU) of the proposed AMC from the description of the corresponding device alone. Analysis showed that before watching the video demonstration of device interaction, 68.61% of the participants reported feeling nervous (TA) about the AMC. However, after watching the video, about 86.86% of them were able to better perceive its ease of use (PEU) and 96.35% of them reported feeling confident (PBC) about using it to complete a computing activity. This can be validated from the structural model in Fig 5, as both PEU and PI had significant positive influences on PU and PBC (the hypothesis H3, H4, H14, and H16 were supported). Furthermore, the constructs PU, PEU, and PBC had significant positive influences on ATU, supporting the hypotheses H1, H5, and H12, respectively. The participants claimed that they were encouraged to use the AMC by their peers (SN) in about 80.65% of the situations. Because of these reasons and how they perceived the AMC, most of them (about 96.44%) had a favorable attitude (ATU) toward it. Additionally, almost 88.56% of them indicated a positive intention (BI) to incorporate it into their way of life. Although prior studies have reported PU to have a direct significant effect on BI, the same was not observed in the context of this study, and therefore H2 was not supported, which aligns with evidence found in the literature [39]. However, the constructs ATU and PBC were found to have significant positive influences on BI, supporting the hypotheses H10 and H13, respectively. The motivation from their peers may have contributed to them being able to perceive the usefulness and ease of using the AMC better, while enhancing their positive attitude towards and intention to accept it. Consequently, SN was found to have significant positive influences on the constructs PU, PEU, ATU, and BI (the hypotheses H6, H7, H8, and H9 were supported, respectively). These findings are consistent with prior studies related to technology adoption [39, 44, 49, 54, 60, 66]. Both of the constructs TA and PI had insignificant influences on PEU (the hypotheses H11 and H15 were not supported, respectively) while maintaining consistency with the results of prior studies [38, 39] as well. Furthermore, PI did not have any significant positive influence on ATU and BI of the AMC (the hypotheses H17 and H18 were not supported, respectively) as well. Fig 6 depicts the average distribution of participant responses for each of the psychological constructs considered in this study. The TAM path model of the proposed research model using SEM analysis is given in Fig 5.
Structural Equation Modelling (SEM) was used for this purpose. The model shows standardized β-coefficients of the significant influences only.
[PU: Perceived Usefulness, PEU: Perceived Ease of Use, SN: Subjective Norm, PI: Personal Innovativeness, TA: Technology Anxiety, PBC: Perceived Behavioral Control, ATU: Attitude Towards Usage, and BI: Behavioral Intention].
After the hypotheses were tested, the explanatory power of the research model was assessed using the R2-values of regression analysis. Prior studies have stated that R2-values greater than 0.67, 0.33, and 0.19 can be termed, “substantial”, “moderate”, and “weak”, respectively [66]. It was found that the proposed model explained about 49.02% of the variation in users’ Attitude Towards Usage (ATU) and 53.71% of the variation in their Behavioral Intention (BI) to accept the proposed AMC for their interaction with a computer. The corresponding R2-values, along with the F-statistics and the corresponding p-value of the other constructs, ATU, PU, PEU, and PBC are reported in Table 7. It can be observed from this table that all the predictions were significant at p ≤ 0.001. Furthermore, the constructs TA, SN, and PI altogether, explained about 10.50% of the variation in PEU, with SN being a significant predictor. Although the R2-value of PEU was very low compared to the other constructs, it was statistically significant at p = 0.001 and exceeded the recommended benchmark, which requires R2 being greater than 0.10 [45, 51]. It can also be observed from Table 7 that the R2 values exhibited an increasing trend as the model proceeds towards determining BI of accepting the proposed AMC, which indicated that the predictors of the research model were adequate in the context of this study. In connection to this, it can be established that the model explained an acceptable variation in the predicted constructs—PU, PEU, PBC, ATU, and BI. Furthermore, the relative fit of the structural model was analyzed using various fit indices (e.g., χ2/df, GFI, AGFI, CFI, TLI, NFI, RMSEA), as shown in Table 8. It is evident from this table that the values of all the indices were consistent with their recommended threshold values [49, 67, 69, 80, 81, 93–100]., which suggest a good model fit.
Discussion
The purpose of this study was to develop a working prototype of a sensor-based head-mounted Assistive Mouse Controller (AMC), followed by a TAM-based analysis of its acceptability to the people with upper limb disabilities from the socioeconomic perspective of Bangladesh.
To reduce the risk of an ineffective and impractical prototype design, it is imperative to adopt a user-centered design approach [101] while considering their inputs to get a proper understanding of their requirements. However, due to the onset of COVID-19, it was challenging for us to recruit individuals or focus groups to carry out primary user-based requirement analysis through face-to-face interview sessions. Nonetheless, we were able to overcome this challenge by analyzing prior research [8] for specific design principles as part of user requirements in such contexts. Initially, we considered the eye wink gesture for actuating mouse clicks. However, long-term interaction with a computer involving frequent eye wink gestures can cause eye strain, leading to headaches [102]. Considering the long-term health issues of this gesture, it was challenging for us to consider an alternative generic facial gesture for this purpose. However, after rigorous analysis and brainstorming sessions, and with motivation from prior research [103], we adopted cheek muscle twitches for actuating mouse clicks using the proposed AMC.
For analyzing users’ acceptability of the proposed AMC, 18 hypotheses were postulated, which involved the 5 original constructs of TAM (PU, PEU, SN, ATU, and BI) along with 3 external constructs relevant to the socioeconomic perspective of Bangladesh (TA, PBC, and PI). To the best of our knowledge, the TAM-based acceptability analysis of an AMC is the first of its kind in such a context. The proposed TAM model can explain about, 49.02% and 53.71% of the variation in users’ positive attitude and intention to adopt the proposed AMC, respectively. Since the use of ATs is not widespread in Bangladesh let alone that of an AMC [13–16], it is natural for the people with upper limb disabilities in Bangladesh to exhibit signs of anxiety, lack of confidence, and innovation about the acceptance of the proposed AMC aimed towards equitable human-computer interaction. However, the users may be able to overcome these psychological shortcomings if first-hand interaction with it can be ensured through a trial usage period, subject to further investigation. Considering the beta coefficients of the positive significant influences of different psychological constructs on the participants’ attitude towards using the AMC (as seen from Table 6), they must be able to perceive its usefulness first, followed by its ease of use, and lastly, receive support, education, and motivation from the society to be able to interact with a computer for improving their socioeconomic status. Therefore, if proper initiatives to motivate, educate, and train them are taken by different government and/or private organizations in Bangladesh, the acceptability of the proposed AMC by the stakeholders may be ensured with a higher probability of success [37]. However, based on our findings, we may safely state that the participants endorsed the easy, simple, and intuitive interaction mechanisms of the AMC, which along with their innovative mindset, and support from their peers enabled them to perceive its usefulness better while enhancing their confidence in and attitude towards using it for carrying out a computing task.
Although our findings suggest that the current prototype of the AMC is potentially highly acceptable to the stakeholders, one major limitation of our study is that they could not interact with the AMC firsthand due to the onset of COVID-19, and therefore, they might not have perceived the practical implications of its usage just by watching a video demonstration of device interaction. This implies that the results of the TAM analysis are specific to this study and may not hold for a different wearable AMC technology in a different context. Therefore, future research may be focused on improving the explanatory power of the same or a different model with the same or an advanced prototype of the AMC, while facilitating first-hand device interaction, considering a larger sample size, or exploring a wide range of psychological constructs that were not considered in this study, such as—perceived enjoyment, perceived ubiquity, pricing, facilitating conditions, aesthetics, resistance to change, compatibility, etc. Furthermore, since actual usage of the proposed AMC could not be facilitated for the participants of the study, we were unable to measure the influence of users’ positive BI to use the proposed device on its actual usage. Therefore, we express our keen interest to explore this research avenue through a longitudinal cohort study in the future. Another potential future avenue of research may be to understand how a user adapts to performing specific tasks with the device over time, by measuring their decrease in reaction times. In this regard, the power law of practice [104] may be utilized, according to which the logarithm of response time for a certain task decreases linearly with the logarithm of practice trials encountered. Furthermore, we intend to analyze and assess the usability [101, 105–107] of the proposed AMC, while leveraging the System Usability Scale (SUS) in the future. It may help us modify existing gestures or add novel ones so that both the disabled community and the academic research body can benefit from its usage.
To summarize, the findings of this study suggest that for the proposed AMC, in addition to perceived usefulness, ease of use, and positive social influence, a high level of confidence owing to the easier working mechanism of the device and highly innovative personality significantly influences positive attitude and intention towards using the device from the socioeconomic perspective of Bangladesh.
References
- 1. Zhao R, Wang J. Visualizing the research on pervasive and ubiquitous computing. Scientometrics. 2011;86(3):593–612.
- 2. Raghavan P. Upper limb motor impairment after stroke. Physical Medicine and Rehabilitation Clinics. 2015;26(4):599–610. pmid:26522900
- 3. Dewan MC, Rattani A, Baticulon RE, Faruque S, Johnson WD, Dempsey RJ, et al. Operative and consultative proportions of neurosurgical disease worldwide: estimation from the surgeon perspective. Journal of neurosurgery. 2018;130(4):1098–1106. pmid:29749918
- 4. Reddihough DS, Collins KJ. The epidemiology and causes of cerebral palsy. Australian Journal of physiotherapy. 2003;49(1):7–12. pmid:12600249
- 5. Roller NW, Garfunkel A, Nichols C, Ship II. Amyotrophic lateral sclerosis. Oral Surgery, Oral Medicine, Oral Pathology. 1974;37(1):46–52. pmid:4519446
- 6. Sarvestani AS, Azam AT. Amputation: a ten-year survey. Trauma monthly. 2013;18(3):126.
- 7. Carmona RH. The global challenges of birth defects and disabilities. The lancet. 2005;366(9492):1142–1144. pmid:16198750
- 8. Moon NW, Baker PM, Goughnour K. Designing wearable technologies for users with disabilities: Accessibility, usability, and connectivity factors. Journal of Rehabilitation and Assistive Technologies Engineering. 2019;6:2055668319862137. pmid:35186318
- 9. Harris N. The design and development of assistive technology. IEEE Potentials. 2017;36(1):24–28.
- 10. Sadat A, Podder V, Biswas R. Stroke Strikes in Bangladesh: Current Insights and Future Directions. Cureus. 2023;15(4). pmid:37213980
- 11. Mondal MBA, Hasan AH, Khan N, Mohammad QD. Prevalence and risk factors of stroke in Bangladesh: A nationwide population-based survey. Eneurologicalsci. 2022;28:100414. pmid:35769921
- 12. Venketasubramanian N, Mannan M. Stroke burden and stroke services in Bangladesh. Cerebrovascular Diseases Extra. 2021;11(2):69–71. pmid:34247155
- 13.
Organization WH, et al.. Global report on assistive technology; 2022.
- 14. Karki J, Rushton S, Bhattarai S, De Witte L. Access to assistive technology for persons with disabilities: a critical review from Nepal, India and Bangladesh. Disability and Rehabilitation: Assistive Technology. 2023;18(1):8–16. pmid:33651968
- 15. Karki J, Rushton S, Bhattarai S, Norman G, Rakhshanda S, De Witte PL. Processes of assistive technology service delivery in Bangladesh, India and Nepal: a critical reflection. Disability and Rehabilitation: Assistive Technology. 2022; p. 1–10. pmid:35746866
- 16. Nuri RP, Xu X, Aldersey HM. Users’ satisfaction and experiences in using assistive devices distributed by a rehabilitation centre in Bangladesh: a cross-sectional study. Disability and Rehabilitation: Assistive Technology. 2022; p. 1–10. pmid:36215415
- 17. Borg J, Östergren PO, Larsson S, Rahman AA, Bari N, Khan AN. Assistive technology use is associated with reduced capability poverty: a cross-sectional study in Bangladesh. Disability and Rehabilitation: Assistive Technology. 2012;7(2):112–121. pmid:21851288
- 18. Borg J, Östergren PO. Users’ perspectives on the provision of assistive technologies in Bangladesh: awareness, providers, costs and barriers. Disability and Rehabilitation: Assistive Technology. 2015;10(4):301–308. pmid:25347347
- 19.
Raihan MR, Shams AB, Ahmad M. Wearable multifunctional computer mouse based on EMG and gyro for amputees. In: 2020 2nd International Conference on Advanced Information and Communication Technology (ICAICT). IEEE; 2020. p. 129–134.
- 20.
Fouché R. Head mouse: generalisability of research focused on the disabled to able bodied users. In: Proceedings of the South African Institute of Computer Scientists and Information Technologists. Association for Computing Machinery; New York; NY; United States.; 2017. p. 1–10.
- 21.
HeydariGorji A, Safavi SM, Lee CT, Chou PH. Head-mouse: A simple cursor controller based on optical measurement of head tilt. In: 2017 IEEE Signal Processing in Medicine and Biology Symposium (SPMB). IEEE; 2017. p. 1–5.
- 22. Velasco MA, Clemotte A, Raya R, Ceres R, Rocon E. A novel head cursor facilitation technique for cerebral palsy: Functional and clinical implications. Interacting with Computers. 2017;29(5):755–766.
- 23.
Marjanovic N, Kerr K, Aranda R, Hickey R, Esmailbeigi H. Wearable wireless user interface cursor-controller (uic-c). In: 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). IEEE; 2017. p. 3852–3855.
- 24. Zhang X, Liu X, Yuan SM, Lin SF. Eye tracking based control system for natural human-computer interaction. Computational intelligence and neuroscience. 2017;2017. pmid:29403528
- 25.
Sabab SA, Hussain SR, Mahmud H, Kabir MH, Hasan MK. EYE POINTER: A real time cost effective computer controlling system using eye and head movement. In: Proc. 9th Int. Conf. Adv. Comput.-Hum. Interact.; 2016. p. 153–159.
- 26. Sabab SA, Kabir MR, Hussain SR, Mahmud H, Rubaiyeat HA, Hasan MK. VIS-iTrack: Visual Intention Through Gaze Tracking Using Low-Cost Webcam. IEEE Access. 2022;10:70779–70792.
- 27. Igual C, Igual J, Hahne JM, Parra LC. Adaptive auto-regressive proportional myoelectric control. IEEE Transactions on Neural Systems and Rehabilitation Engineering. 2019;27(2):314–322. pmid:30676969
- 28.
O’Meara SM, Shyr MC, Lyons KR, Joshi SS. Comparing two different cursor control methods which use single-site surface electromyography. In: 2019 9th international IEEE/EMBS conference on neural engineering (NER). IEEE; 2019. p. 1163–1166.
- 29. Teng G, He Y, Zhao H, Liu D, Xiao J, Ramkumar S. Design and development of human computer interface using electrooculogram with deep learning. Artificial intelligence in medicine. 2020;102:101765. pmid:31980102
- 30. Ding X, Lv Z. Design and development of an EOG-based simplified Chinese eye-writing system. Biomedical Signal Processing and Control. 2020;57:101767.
- 31. Lin CT, King JT, Bharadwaj P, Chen CH, Gupta A, Ding W, et al. EOG-based eye movement classification and application on HCI baseball game. IEEE Access. 2019;7:96166–96176.
- 32. Xiao J, Qu J, Li Y. An electrooculogram-based interaction method and its music-on-demand application in a virtual reality environment. IEEE Access. 2019;7:22059–22070.
- 33.
Lingegowda DR, Amrutesh K, Ramanujam S. Electrooculography based assistive technology for ALS patients. In: 2017 IEEE international conference on consumer electronics-Asia (ICCE-Asia). IEEE; 2017. p. 36–40.
- 34. Triadi T, Wijayanto I, Hadiyoso S. Electrooculogram (EOG) based mouse cursor controller using the continuous wavelet transform and statistic features. Lontar Komputer: Jurnal Ilmiah Teknologi Informasi. 2021;12(1):53–61.
- 35. McFarland DJ, Krusienski DJ, Sarnacki WA, Wolpaw JR. Emulation of computer mouse control with a noninvasive brain–computer interface. Journal of neural engineering. 2008;5(2):101. pmid:18367779
- 36. Islam MN, Moniruzzaman M, Khalil MI, Basri R, Alam MK, Loo KW, et al. Burden of stroke in Bangladesh. International journal of stroke. 2013;8(3):211–213. pmid:22974096
- 37.
Dirks S, Bühler C. Assistive technologies for people with cognitive impairments–which factors influence technology acceptance? In: Universal Access in Human-Computer Interaction. Methods, Technologies, and Users: 12th International Conference, UAHCI 2018, Held as Part of HCI International 2018, Las Vegas, NV, USA, July 15-20, 2018, Proceedings, Part I 12. Springer; 2018. p. 503–516.
- 38. Lin WY, Chou WC, Tsai TH, Lin CC, Lee MY. Development of a wearable instrumented vest for posture monitoring and system usability verification based on the technology acceptance model. Sensors. 2016;16(12):2172. pmid:27999324
- 39. Tsai TH, Lin WY, Chang YS, Chang PC, Lee MY. Technology anxiety and resistance to change behavioral study of a wearable cardiac warming system using an extended TAM for older adults. PloS one. 2020;15(1):e0227270. pmid:31929560
- 40. Davis FD, Bagozzi RP, Warshaw PR. User acceptance of computer technology: A comparison of two theoretical models. Management science. 1989;35(8):982–1003.
- 41. Davis FD. Perceived usefulness, perceived ease of use, and user acceptance of information technology. MIS Q 13 (3): 319; 1989.
- 42. Venkatesh V, Davis FD. A theoretical extension of the technology acceptance model: Four longitudinal field studies. Management science. 2000;46(2):186–204.
- 43. Lee SY, Lee K. Factors that influence an individual’s intention to adopt a wearable healthcare device: The case of a wearable fitness tracker. Technological Forecasting and Social Change. 2018;129:154–163.
- 44. Talukder MS, Chiong R, Bao Y, Hayat Malik B. Acceptance and use predictors of fitness wearable technology and intention to recommend: An empirical study. Industrial Management & Data Systems. 2019;119(1):170–188.
- 45. Cheung ML, Chau KY, Lam MHS, Tse G, Ho KY, Flint SW, et al. Examining consumers’ adoption of wearable healthcare technology: The role of health attributes. International journal of environmental research and public health. 2019;16(13):2257. pmid:31247962
- 46.
Liu H, Or C, Lou V, Hu Y, Xi N. Perceptions of and Intention to Use Wearable and Assistive Devices Among Older Adults. In: 14th International Conference on Applied Human Factors and Ergonomics (AHFE). AHFE; 2023. p. 101–110.
- 47.
Onofrio R, Gandolla M, Lettieri E, Pedrocchi AG. Acceptance model of an innovative assistive technology by neurological patients with a motor disability of their upper limb. In: Advances in Usability, User Experience, Wearable and Assistive Technology: Proceedings of the AHFE 2020 Virtual Conferences on Usability and User Experience, Human Factors and Assistive Technology, Human Factors and Wearable Technologies, and Virtual Environments and Game Design, July 16-20, 2020, USA. Springer; 2020. p. 907–913.
- 48. Theodorou P, Meliones A. Developing apps for people with sensory disabilities, and implications for technology acceptance models. Global Journal of Information Technology: Emerging Technologies. 2019;9(2):33–40.
- 49. Ahmad A, Rasul T, Yousaf A, Zaman U. Understanding factors influencing elderly diabetic patients’ continuance intention to use digital health wearables: extending the technology acceptance model (TAM). Journal of Open Innovation: Technology, Market, and Complexity. 2020;6(3):81.
- 50. Lunney A, Cunningham NR, Eastin MS. Wearable fitness technology: A structural investigation into acceptance and perceived fitness outcomes. Computers in Human Behavior. 2016;65:114–120.
- 51. Hong JC, Lin PH, Hsieh PC. The effect of consumer innovativeness on perceived value and continuance intention to use smartwatch. Computers in Human Behavior. 2017;67:264–272.
- 52. Chuah SHW, Rauschnabel PA, Krey N, Nguyen B, Ramayah T, Lade S. Wearable technologies: The role of usefulness and visibility in smartwatch adoption. Computers in Human Behavior. 2016;65:276–284.
- 53. Lee SM, Lee D. Healthcare wearable devices: an analysis of key factors for continuous use intention. Service Business. 2020;14(4):503–531.
- 54. Al-Emran M, Al-Maroof R, Al-Sharafi MA, Arpaci I. What impacts learning with wearables? An integrated theoretical model. Interactive learning environments. 2022;30(10):1897–1917.
- 55.
Mertins B, Austermann J. Technology Acceptance Model Revised: An Investigation on the Managerial Attitudes towards Using Social Media in Innovation Processes; 2014.
- 56. Lu J, Yao JE, Yu CS. Personal innovativeness, social influences and adoption of wireless Internet services via mobile technology. The journal of strategic Information Systems. 2005;14(3):245–268.
- 57. Liu K, Or CK, So M, Cheung B, Chan B, Tiwari A, et al. A longitudinal examination of tablet self-management technology acceptance by patients with chronic diseases: Integrating perceived hand function, perceived visual function, and perceived home space adequacy with the TAM and TPB. Applied Ergonomics. 2022;100:103667. pmid:34920356
- 58. Chen T, Or CK. Perceptions of a machine learning-based lower-limb exercise training system among older adults with knee pain. Digital Health. 2023;9:20552076231186069. pmid:37426581
- 59. Or CK, Karsh BT. A systematic review of patient acceptance of consumer health information technology. Journal of the American Medical Informatics Association. 2009;16(4):550–560. pmid:19390112
- 60. Ozkan S, Kanat IE. e-Government adoption model based on theory of planned behavior: Empirical validation. Government Information Quarterly. 2011;28(4):503–513.
- 61. Alkawsi G, Ali N, Baashar Y. The moderating role of personal innovativeness and users experience in accepting the smart meter technology. Applied Sciences. 2021;11(8):3297.
- 62. Agarwal R, Prasad J. A conceptual and operational definition of personal innovativeness in the domain of information technology. Information systems research. 1998;9(2):204–215.
- 63. Dabholkar PA, Bagozzi RP. An attitudinal model of technology-based self-service: moderating effects of consumer traits and situational factors. Journal of the academy of marketing science. 2002;30:184–201.
- 64. Pimentel JL. A note on the usage of Likert Scaling for research data analysis. USM R&D Journal. 2010;18(2):109–112.
- 65. Chen T, Chen J, Or CK, Lo FP. Path analysis of the roles of age, self-efficacy, and TAM constructs in the acceptance of performing upper limb exercises through immersive virtual reality games. International Journal of Industrial Ergonomics. 2022;91:103360.
- 66. Felea M, Bucur M, Negruţiu C, Nitu M, Stoica DA. Wearable technology adoption among Romanian Students: A structural model based on TAM. Amfiteatru Economic. 2021;23(57):376–391.
- 67. Kim KJ, Shin DH. An acceptance model for smart watches: Implications for the adoption of future wearable technology. Internet Research. 2015;.
- 68. Martínez-Torres MdR, Toral Marín S, García FB, Vazquez SG, Oliva MA, Torres T. A technological acceptance of e-learning tools used in practical and laboratory teaching, according to the European higher education area. Behaviour & Information Technology. 2008;27(6):495–505.
- 69. Marakhimov A, Joo J. Consumer adaptation and infusion of wearable devices for healthcare. Computers in Human Behavior. 2017;76:135–148.
- 70. Shrestha N. Factor analysis as a tool for survey analysis. American Journal of Applied Mathematics and Statistics. 2021;9(1):4–11.
- 71. Fornell C, Larcker DF. Evaluating structural equation models with unobservable variables and measurement error. Journal of marketing research. 1981;18(1):39–50.
- 72. Kabir MR, Abedin MI, Ahmed R, Mahmud H, Hasan MK. ANTASID: A Novel Temporal Adjustment to Shannon’s Index of Difficulty for Quantifying the Perceived Difficulty of Uncontrolled Pointing Tasks. IEEE Access. 2022;10:21774–21786.
- 73. Fornell C, Bookstein FL. Two structural equation models: LISREL and PLS applied to consumer exit-voice theory. Journal of Marketing research. 1982;19(4):440–452.
- 74. Martínez-Torres MdR, Toral Marín S, García FB, Vázquez SG, Oliva MA, Torres T. A technological acceptance of e-learning tools used in practical and laboratory teaching, according to the European higher education area. Behaviour & Information Technology. 2008;27(6):495–505.
- 75. Liao S, Hong JC, Wen MH, Pan YC, et al. Applying technology acceptance model (TAM) to explore users’ behavioral intention to adopt a performance assessment system for E-book production. EURASIA Journal of Mathematics, Science and Technology Education. 2018;14(10):em1601.
- 76. Morata-Ramírez MdlÁ, Holgado-Tello FP. Construct validity of Likert scales through confirmatory factor analysis: A simulation study comparing different methods of estimation based on Pearson and polychoric correlations. Int’l J Soc Sci Stud. 2013;1:54.
- 77. Savalei V, Bonett DG, Bentler PM. CFA with binary variables in small samples: A comparison of two methods. Frontiers in psychology. 2015;5:1515. pmid:25709585
- 78. Koğar H, KOĞAR EY. Comparison of different estimation methods for categorical and ordinal data in confirmatory factor analysis. Journal of Measurement and Evaluation in Education and Psychology. 2015;6(2).
- 79. Alambaigi A, Ahangari I. Technology acceptance model (TAM) as a predictor model for explaining agricultural experts behavior in acceptance of ICT. International Journal of Agricultural Management and Development (IJAMAD). 2016;6(1047-2017-1663):235–247.
- 80. Baumgartner H, Homburg C. Applications of structural equation modeling in marketing and consumer research: A review. International journal of Research in Marketing. 1996;13(2):139–161.
- 81. Doll WJ, Raghunathan T, Lim JS, Gupta YP. A confirmatory factor analysis of the user information satisfaction instrument. Information Systems Research. 1995;6(2):177–188.
- 82. Elprama SA, Vanderborght B, Jacobs A. An industrial exoskeleton user acceptance framework based on a literature review of empirical studies. Applied Ergonomics. 2022;100:103615. pmid:34847372
- 83. Pacifico I, Aprigliano F, Parri A, Cannillo G, Melandri I, Sabatini AM, et al. Evaluation of a spring-loaded upper-limb exoskeleton in cleaning activities. Applied Ergonomics. 2023;106:103877. pmid:36095895
- 84. Ariansyah D, Erkoyuncu JA, Eimontaite I, Johnson T, Oostveen AM, Fletcher S, et al. A head mounted augmented reality design practice for maintenance assembly: Toward meeting perceptual and cognitive needs of AR users. Applied Ergonomics. 2022;98:103597. pmid:34598078
- 85. Ferrario VF, Sforza C, Serrao G, Grassi G, Mossi E. Active range of motion of the head and cervical spine: a three-dimensional investigation in healthy young adults. Journal of orthopaedic research. 2002;20(1):122–129. pmid:11853078
- 86. Miller J, Khera O. Digital library adoption and the technology acceptance model: A cross-country analysis. The Electronic Journal of Information Systems in Developing Countries. 2010;40(1):1–19.
- 87.
Haugstvedt AC, Krogstie J. Mobile augmented reality for cultural heritage: A technology acceptance study. In: 2012 IEEE international symposium on mixed and augmented reality (ISMAR). IEEE; 2012. p. 247–255.
- 88. Sprenger DA, Schwaninger A. Video demonstrations can predict the intention to use digital learning technologies. British Journal of Educational Technology. 2023;.
- 89. Pimentel JL, Pimentel J. Some biases in Likert scaling usage and its correction. International Journal of Science: Basic and Applied Research (IJSBAR). 2019;45(1):183–191.
- 90. Croasmun JT, Ostrom L. Using likert-type scales in the social sciences. Journal of adult education. 2011;40(1):19–22.
- 91. Chang L. A psychometric evaluation of 4-point and 6-point Likert-type scales in relation to reliability and validity. Applied psychological measurement. 1994;18(3):205–215.
- 92. Igolkina AA, Meshcheryakov G. semopy: A python package for structural equation modeling. Structural Equation Modeling: A Multidisciplinary Journal. 2020;27(6):952–963.
- 93. Hu Lt, Bentler PM. Cutoff criteria for fit indexes in covariance structure analysis: Conventional criteria versus new alternatives. Structural equation modeling: a multidisciplinary journal. 1999;6(1):1–55.
- 94. Kim KJ, Sundar SS. Does screen size matter for smartphones? Utilitarian and hedonic effects of screen size on smartphone adoption. Cyberpsychology, Behavior, and Social Networking. 2014;17(7):466–473. pmid:24694112
- 95.
Bartholomew DJ, Knott M, Moustaki I. Latent variable models and factor analysis: A unified approach. John Wiley & Sons; 2011.
- 96. Gefen D, Straub D, Boudreau MC. Structural equation modeling and regression: Guidelines for research practice. Communications of the association for information systems. 2000;4(1):7.
- 97. Singh R, Sandhu HS, Metri BA, Kaur R, et al. Organizational performance and retail challenges: a structural equation approach. iBusiness. 2011;3(02):159.
- 98. Browne MW, Cudeck R. Alternative ways of assessing model fit. Sociological methods & research. 1992;21(2):230–258.
- 99. Bentler PM, Bonett DG. Significance tests and goodness of fit in the analysis of covariance structures. Psychological bulletin. 1980;88(3):588.
- 100. Bentler PM. Comparative fit indexes in structural models. Psychological bulletin. 1990;107(2):238. pmid:2320703
- 101.
Or CK, Holden RJ, Valdez RS. Human factors engineering and user-centered design for mobile health technology: enhancing effectiveness, efficiency, and satisfaction. In: Human-Automation Interaction: Mobile Computing. Springer; 2022. p. 97–118.
- 102. Bates R, Istance HO. Why are eye mice unpopular? A detailed comparison of head and eye controlled assistive technology pointing devices. Universal Access in the Information Society. 2003;2:280–290.
- 103.
Sancheti K, Suhaas A, Suresh P, et al. Hands-free cursor control using intuitive head movements and cheek muscle twitches. In: TENCON 2018-2018 IEEE Region 10 Conference. IEEE; 2018. p. 0356–0361.
- 104. Johnson EJ, Bellman S, Lohse GL. Cognitive lock-in and the power law of practice. Journal of Marketing. 2003;67(2):62–75.
- 105.
de Godoi TX, Valentim NMC. Towards an Integrated Evaluation of Usability, User Experience and Accessibility in Assistive Technologies. In: Proceedings of the XVIII Brazilian Symposium on Software Quality; 2019. p. 234–239.
- 106. Or C, Tao D, et al. Usability study of a computer-based self-management system for older adults with chronic diseases. JMIR Research Protocols. 2012;1(2):e2184. pmid:23612015
- 107.
Tao D, Or C. A paper prototype usability study of a chronic disease self-management system for older adults. In: 2012 IEEE International Conference on Industrial Engineering and Engineering Management. IEEE; 2012. p. 1262–1266.