Figures
Abstract
Objective
Timely application of surfactant replacement therapy is critical for neonates with respiratory distress syndrome (RDS). Presently, early clinical decision on surfactant use relies solely on ventilator parameters. However, ventilator parameters are unable to truly recapitulate the extent of surfactant deficiency. Lung ultrasound has been increasingly used in the early prediction of surfactant use in recent years, but its predictive value remains unclear. Therefore, we conducted this study to examine its predictive value in surfactant use and determine the optimal timing and cutoff value.
Methods
Studies on neonates with respiratory distress or diagnosed with RDS were collected from PubMed, Embase, Cochrane Library, and Web of Science. Primary outcomes included sensitivity, specificity, and positive and negative predictive values of lung ultrasound.
Results
Ten eligible studies with 1162 participants were included. The sensitivity and specificity of lung ultrasound in predicting surfactant use were 0.86 (95% CI: 0.81–0.90) and 0.82 (95% CI: 0.71–0.90), respectively. Lung ultrasound performed within 1–3 h after birth had a sensitivity of 0.89 (95% CI: 0.79–0.95) and a Youden’s index of 0.67. Compared with a lung ultrasound score (LUS) cutoff of ≤6/7, ≤8, >5, >6/7, and >8, a LUS cutoff of ≤5 had higher Youden’s index (0.73) and sensitivity (0.94, 95% CI: 0.85–0.97) in predicting surfactant use.
Citation: Luo K, Wang H, Huang F, Tang J (2023) Optimal timing and cutoff range of lung ultrasound in predicting surfactant administration in neonates: A meta-analysis and systematic review. PLoS ONE 18(7): e0287758. https://doi.org/10.1371/journal.pone.0287758
Editor: Atnafu Mekonnen Tekleab, St Paul’s Hospital Millennium Medical College, ETHIOPIA
Received: April 23, 2023; Accepted: June 11, 2023; Published: July 27, 2023
Copyright: © 2023 Luo et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the paper and its Supporting information files.
Funding: This work was supported by National Natural Science Foundation of China (General Project, 82171710). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Competing interests: The authors have declared that no competing interests exist.
Introduction
Surfactant replacement therapy has been shown to effectively improve early respiratory distress and late prognosis of respiratory distress syndrome (RDS) neonates within 3 h of birth [1]. Current clinical practices emphasize the early use of surfactant to improve prognosis of neonates exhibiting symptoms of respiratory distress, such as shortness of breath, grunting, dyspnea, and transcutaneous oxygen saturation of <0.90 in the absence of oxygen inhalation [2]. However, not all neonates require surfactant since those with transient tachypnea of the newborn (TTN) may exhibit these symptoms. Therefore, clinical guidelines [3] and expert consensus [4] have added the use of ventilator parameters when determining surfactant use. The 2019 European Consensus Guidelines recommended FiO2 > 0.30 as the dosing cutoff for all neonates with clinically diagnosed RDS [3]. In addition, the 2021 Chinese Expert Consensus specified that a CPAP ≥6 cmH2O is an indication for surfactant use [4]. However, ventilator parameters are unable to truly recapitulate the extent of surfactant deficiency and are largely influenced by the type of respiratory support and degree of oxygenation. Thus, there are limitations in solely relying on clinical symptoms and ventilator parameters when determining surfactant use, which can result in unnecessary surfactant use or missing the best timing of surfactant.
Due to its timeliness, convenience, and radiation-free advantages, lung ultrasound has gained wide application in the neonatal ward in recent years. Two meta-analyses in 2020 pointed out that lung ultrasound has relatively high sensitivity and specificity for diagnosing neonatal RDS and may replace chest X-ray as the diagnostic measure [5, 6]. In addition, lung ultrasound has also demonstrated relatively high accuracy in diagnosing neonatal TTN [7]. Furthermore, Liu et al. [8] established standards and guidelines for the instrument operation and parameter setting of lung ultrasound in neonates, which further improved the accuracy and reliability of the procedure. Though, it is worth noting that qualitative evaluation by lung ultrasound is somewhat subjective, which renders the procedure difficult for wide clinical application. Moreover, only using lung ultrasound as a means of disease diagnosis cannot maximize its role in assessing pulmonary oxygenation in neonates. Consequently, Brat et al. [9] designed a scoring system that allows semi-quantitation by lung ultrasound. Furthermore, other studies have used the distribution of A-lines and B-lines to classify lung ultrasound images into different types [10, 11]. It has been reported that lung ultrasound score (LUS) can effectively identify failure of noninvasive assisted ventilation in neonatal RDS patients [11–14]. This then raises the question of whether LUS can predict surfactant use in RDS patients. Although many studies have confirmed the significance of LUS in guiding surfactant use [9, 15–26], the LUS cutoff value was inconsistently selected based on gestational age [9] or different timing of lung ultrasound [22]. Here, we performed a meta-analysis of the predictive value of lung ultrasound in surfactant use and assessed the optimal LUS cutoff value and timing of lung ultrasound to standardize the clinical application of surfactant and to rationalize and refine the treatment of neonatal diseases.
Methods
This systematic review and meta-analysis was conducted in accordance with the PRISMA statement [27] and has been registered on PROSPERO (Registration No. CRD42022359004) [28].
Inclusion and exclusion criteria
The included studies were diagnostic accuracy studies, prospective or retrospective cohort and case-control studies. Neonates with signs of respiratory distress or diagnosed with RDS were included. Neonates with chromosomal abnormalities, congenital malformations, congenital lung diseases, and meconium aspiration syndrome, as well as those requiring delivery room surfactant administration were excluded from the study.
Literature search
PubMed, Embase, Cochrane Library, and Web of Science were searched for relevant articles from inception to September 8th, 2022, with no language restriction. Detailed search strategy is provided in S1 File.
Literature screening and data extraction
Literature screening and data extraction were performed by two independent reviewers (Luo and Wang), and any disagreements were consulted with and settled by a third reviewer (Huang).
Data including title, first author, year of publication, study type, study background, number of patients receiving surfactant treatment, total number of patients, standards for surfactant use, timing of lung ultrasound, lung ultrasound evaluation criteria, LUS cutoff, sensitivity, and specificity were extracted into a pre-designed form.
Outcome measures
The outcome measures included sensitivity, specificity, positive and negative predictive values of lung ultrasound, optimal LUS cutoff, and optimal timing of lung ultrasound.
Quality assessment
The methodological qualities of the eligible articles were assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) scoring system. Two authors (Luo and Wang) independently assessed the methodological quality of the included studies and extracted data using RevManager 5.4. Discrepancies were consulted with and settled by a third reviewer (Huang).
Data compilation and analysis
Data were fitted to the bivariate mixed effect model using the "midas" command of Stata 15.0 (StataCorp LLC, College Station, TX), and the point estimates of test sensitivity and specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, summary receiver operating characteristic (SROC) curve, Youden’s index, and the corresponding 95% confidence intervals (Cis) were calculated. Comprehensive SROC curves were plotted, and the area under the curve (AUC) and its 95% CI were calculated. Publication bias was determined by Deeks’ funnel plot, and heterogeneity among studies was determined by Q statistics and I2 statistics. An I2 >50% indicates high heterogeneity, and a P<0.05 was considered statistically significant. Subgroup analyses were performed to discuss sources of heterogeneity. Subgroup analysis was performed on the timing and LUS cutoff of lung ultrasound. To ensure the reliability of the conclusion, each subgroup contained at least 4 sets of data. Different cutoff values were used for meta-analysis, and the optimal cutoff values were selected according to the maximum Youden index.
Results
Study selection
After reading the titles, abstracts and full texts of the 518 related articles, a total of 10 eligible studies with 1162 participants were included.[9, 15, 17–20, 22–24, 26] The flow diagram for study selection is shown in Fig 1. Some of the studies that were excluded for varying reasons are summarized in S1 Table.
Study characteristics
Among the included studies, 5 studies involved neonates diagnosed with RDS [15, 17, 23, 24, 26] and 5 studies involved neonates with symptoms of respiratory distress [9, 18–20, 22]. Five of the studies clearly stated that subjects were first provided with noninvasive ventilation or CPAP [15, 17–20]. With regards to the standards for surfactant use, 7 studies [9, 17, 19, 20, 22, 23, 26] referenced the 2013 [29], 2016 [30], and 2019 [3] European Consensus Guidelines and emphasized on FiO2 monitoring. The FiO2 cutoff was set at 0.3 and 0.4 for extremely and very preterm infants in both the 2013 01:39 PM and 2016 [30] guidelines, respectively, and at 0.3 in the 2019 [3] guidelines. The other 3 articles [15, 18, 24] did not clearly state which guidelines were used for designing the standards for surfactant use but still highlighted the need to focus on ventilator parameters such as FiO2 and SpO2. With regards to the diagnostic criteria for lung ultrasound, 9 articles [9, 15, 17, 18, 20, 22–24, 26] employed the 3-region 18-point scoring system established by Brat et al. [9] in evaluating the lung ultrasound results. One article [19] performed qualitative evaluation by classifying lung ultrasound images into different types based on A-line and B-line distribution [11] but did not provide the diagnostic data. For study type, 9 of the 10 studies were cohort studies [9, 15, 17–20, 22, 23, 26]. Among these studies, those conducted by Brat et al. [9] and Perri et al. [22] set multiple LUS cutoffs based on gestational age or timing of lung ultrasound and obtained the corresponding diagnostic results. On the other hand, De Martino et al. [17] calculated sensitivity and specificity using 3 different LUS cutoffs. One study [24] was a nested cohort study, which concluded that lung ultrasound is helpful for the timely application of surfactant and for improving RDS prognosis. However, this study did not provide diagnostic results and was hence not included in the final data analysis. The basic characteristics of the included studies are shown in S2 Table.
Risk of bias in studies
We evaluated the included studies using the QUADAS-2 tool. All studies avoided a case-control design and a pre-specified threshold, as well as interpreted the reference standard results without knowledge of the results of the index tests, except for a nested cohort study [24], which used a pre-specified cutoff for evaluating lung ultrasound. All the studies could not determine there was an appropriate interval between index test and reference standard (Fig 2).
Surfactant therapy as primary outcome
Meta-analysis of the 12 sets of data from 8 studies [9, 15, 17, 18, 20, 22, 23, 26] revealed that lung ultrasound had a sensitivity of 0.86 (95% CI: 0.81–0.90), specificity of 0.82 (95% CI: 0.71–0.90), positive likelihood ratio of 4.8 (95% CI: 2.9–7.9), negative likelihood ratio of 0.17 (95% CI: 0.11–0.23), and SROC of 0.89 (95% CI: 0.17–1.00) in predicting surfactant use. Deeks’ funnel plot showed no publication bias in each study (P = 0.18). Next, we analyzed the clinical applicability of lung ultrasound using Fagan’s nomogram. By assuming a prior probability of 0.5, the posterior probabilities of requiring and not requiring surfactant treatment after lung ultrasound prediction were 0.83 and 0.15, respectively (Figs 3–6).
Subgroup analysis of timing of lung ultrasound
Since the specific time of lung ultrasound was not provided in the studies by De Martino et al. [17] Raimondi et al. [23] and Vardar et al, [26] we divided the remaining studies into the 1–3 h group and >3 h groups based on the time at which lung ultrasound was performed. The >3 h subgroup was not analyzed due to having only 1 study and 1 set of data [22], which may result in bias. Meta-analysis of the remaining studies showed that lung ultrasound within 1–3 h after birth had a 0.89 (95% CI: 0.79–0.95) sensitivity, 0.78 (95% CI: 0.55–0.91) specificity, and 0.67 Youden’s index for predicting surfactant use (Table 1).
LUS cutoff
Next, we divided the included studies based on LUS cutoff into the ≤5, ≤6/7, ≤8, > 5, > 6/7, and > 8 groups. Meta-analysis showed that a LUS cutoff of ≤5 had a sensitivity of 0.94 (95% CI: 0.85–0.97), a specificity of 0.79 (95% CI: 0.31–0.97), and the highest Youden’s index of 0.73. (Table 1).
Discussion
We performed a comprehensive systematic review of studies that investigated the application of lung ultrasound in predicting surfactant use and showed that lung ultrasound is a good predictor for surfactant replacement therapy in neonates with respiratory distress or diagnosed with RDS (sensitivity: 0.86 (95% CI: 0.81–0.90), specificity: 0.82 (95% CI: 0.71–0.90), SROC: 0.89 (95% CI: 0.71–1.00). Subgroup analyses of the timing of lung ultrasound and LUS cutoff revealed that lung ultrasound within 1–3 h of birth and a LUS cutoff of ≤5 had a relatively high sensitivity (0.89 (95% CI: 0.79–0.95) and 0.94 (95% CI: 0.85–0.97), respectively) and Youden’s index (0.67 and 0.73, respectively) for predicting surfactant use.
We determined an optimal LUS cutoff range by compiling the data from each study. As for the timing of lung ultrasound, our results were consistent with those previously reported. The RCT by Rodriguez-Fanjul et al. [25] found that lung ultrasound within 3 h of birth promotes earlier surfactant treatment and reduces oxygen exposure during the early life of neonates. The nested cohort study by Raschetti et al. [24] showed that lung ultrasound-guided surfactant treatment increased the percent of neonates receiving surfactants within 3 h of birth and decreased the maximum FiO2 reached before surfactant replacement therapy. However, due to the small sample size of subgroups, as well as the heterogeneity among studies that resulted in the inability to use lung ultrasound as the absolute indicator for surfactant use, the manifestations and oxygenation of neonatal patients should still be monitored by clinical observation and ventilator parameters, respectively. Perri et al. [22] investigated the use of LUS in the early prediction of CPAP and surfactant, and found that LUS was significantly correlated with SpO2/FiO2 ratio. Raimondi et al. [23] reported that the combination of LUS and SpO2/FiO2 ratio had the highest AUC (0.93 (95% CI: 0.89–0.97)) in predicting surfactant use than each indicator alone.
Based on the results of this meta-analysis, we recommend the expansion of lung ultrasound application to further make use of its noninvasive, radiation-free and bedside advantages such that it is no longer limited to the diagnosis of RDS and TTN but rather involved in the entire diagnosis and treatment process of RDS. To the best of our knowledge, this is the first meta-analysis demonstrating that lung ultrasound is not only a good predictor for surfactant replacement therapy, but lung ultrasound within 1–3 h after birth and a LUS cutoff of 5 also had higher predictive accuracy.
A meta-analysis published in 2020 included 6 studies that evaluated the diagnostic value of LUS in neonates requiring surfactant or mechanical ventilation. The results showed that the risk of surfactant use was higher when LUS is > 5–6 than when LUS is < 5–6, and LUS was more reliable for neonates with a gestational age <34 weeks than for full term and late preterm neonates [31]. However, a shortcoming of this study was that both surfactant use and mechanical ventilation were regarded as one outcome measure when they are clearly different treatment measures. In addition, given the importance of early treatment in RDS, this meta-analysis did not investigate the significance of lung ultrasound timing. Furthermore, several studies published after this meta-analysis indicated that LUS > 5–6 is no longer the optimal cutoff for predicting surfactant use. In contrast, our meta-analysis included several recently published studies, used surfactant as the only primary outcome, and explored in-depth the appropriate timing of lung ultrasound and the optimal LUS cutoff.
Capasso, L. et al. [32] published a meta-analysis on a similar topic to ours. A total of 7 original studies were included in their meta-analysis, which confirmed the predictive value of lung ultrasound for surfactant use. However, in their meta-analysis, there are large differences in the timing of lung ultrasound among the original studies. Further, there are various cut-off thresholds for lung ultrasound scores, but their study did not provide guidance on the cut-off threshold and the timing of lung ultrasound. In clinical practice, for newborns with respiratory distress or diagnosed with RDS, the timing of lung ultrasound and the selection of scoring cut-off thresholds often make front-line medical workers confused. Our meta added 3 newly published original studies on the basis of their meta-analysis, and fully discussed the optimal timing of lung ultrasoundand the cut-off threshold of lung ultrasound score.
Nonetheless, there are still several limitations in this study. First, differences in patient populations, underlying conditions and methods of respiratory support can impact the degree of surfactant deficiency and oxygenation in neonates and increase the heterogeneity among studies. Second, since the small sample size of subgroups, further studies with larger sample size are needed to confirm the results. Finally, most of the included studies used the lung ultrasound diagnostic criteria developed by Brat et al. [9]. Though, there are also several other qualitative and semi-quantitative methods of lung ultrasound assessment. Therefore, more evidence-based studies are warranted to evaluate the significance of these methods.
Conclusions
Lung ultrasound is a good predictor for surfactant use in neonates with respiratory distress or diagnosed with RDS, and lung ultrasound within 1–3 h after birth and a LUS cutoff of 5 are recommended. Nevertheless, the symptoms and oxygenation of the neonatal patients should still be considered.
Supporting information
S2 Table. Basic characteristics of the included studies.
https://doi.org/10.1371/journal.pone.0287758.s003
(XLSX)
Acknowledgments
We would like to thank the researchers and study participants for their contributions.
References
- 1. Bahadue FL, Soll R. Early versus delayed selective surfactant treatment for neonatal respiratory distress syndrome. Cochrane Database Syst Rev. 2012;11(11):CD001456. pmid:23152207
- 2. Klotz D, Porcaro U, Fleck T, Fuchs H. European perspective on less invasive surfactant administration-a survey. Eur J Pediatr. 2017;176(2):147–154. pmid:27942865
- 3. Sweet DG, Carnielli V, Greisen G, Hallman M, Ozek E, Te Pas A, et al. European Consensus Guidelines on the Management of Respiratory Distress Syndrome—2019 Update. Neonatology. 2019;115(4):432–450. pmid:30974433
- 4. [Consensus for pulmonary surfactant therapy in neonates in China (2021)]. Zhonghua Er Ke Za Zhi. 2021;59(8):627–632. pmid:34333913
- 5. Wu J, Wang Y, Zhao A, Wang Z. Lung Ultrasound for the Diagnosis of Neonatal Respiratory Distress Syndrome: A Meta-analysis. Ultrasound Q. 2020;36(2):102–110. pmid:32511203
- 6. Ma H, Yan W, Liu J. Diagnostic value of lung ultrasound for neonatal respiratory distress syndrome: a meta-analysis and systematic review. Med Ultrason. 2020;22(3):325–333. pmid:32399541
- 7. Ma HR, Liu J, Yan WK. Accuracy and Reliability of Lung Ultrasound to Diagnose Transient Tachypnoea of the Newborn: Evidence from a Meta-analysis and Systematic Review. Am J Perinatol. 2022;39(9):973–979. pmid:33242910
- 8. Liu J, Guo G, Kurepa D, Volpicelli G, Sorantin E, Lovrenski J, et al. Specification and guideline for technical aspects and scanning parameter settings of neonatal lung ultrasound examination. J Matern Fetal Neonatal Med. 2022;35(5):1003–1016. pmid:34182870
- 9. Brat R, Yousef N, Klifa R, Reynaud S, S Aguilera S, De Luca D. Lung Ultrasonography Score to Evaluate Oxygenation and Surfactant Need in Neonates Treated With Continuous Positive Airway Pressure. Jama Pediatrics. 2015;169(8). pmid:26237465
- 10. Blank DA, Rogerson SR, Kamlin COF, Fox LM, Lorenz L, Kane SC, et al. Lung ultrasound during the initiation of breathing in healthy term and late preterm infants immediately after birth, a prospective, observational study. Resuscitation. 2017;114:59–65. pmid:28249708
- 11. Raimondi F, Migliaro F, Sodano A, Ferrara T, Lama S, Vallone G, et al. Use of neonatal chest ultrasound to predict noninvasive ventilation failure. Pediatrics. 2014;134(4):e1089–94. pmid:25180278
- 12. Raimondi F, Yousef N, Fanjul JR, De Luca D, Corsini I, Shankar-Aguilera S, et al. A Multicenter Lung Ultrasound Study on Transient Tachypnea of the Neonate. Neonatology. 2019;115(3):263–268. pmid:30731475
- 13. Raimondi F, Migliaro F, Sodano A, Umbaldo A, Romano A, Vallone G, et al. Can neonatal lung ultrasound monitor fluid clearance and predict the need of respiratory support? Crit Care. 2012;16(6):R220. pmid:23151314
- 14. Raimondi F, Yousef N, Migliaro F, Capasso L, De Luca D. Point-of-care lung ultrasound in neonatology: classification into descriptive and functional applications. Pediatric Research. 2021;90(3):524–531. pmid:30127522
- 15. Aldecoa-Bilbao V, Balcells-Esponera C, Herranz Barbero A, Borràs-Novell C, Izquierdo Renau M, Iriondo Sanz M, et al. Lung ultrasound for early surfactant treatment: Development and validation of a predictive model. Pediatr Pulmonol. 2021;56(2):433–441. pmid:33369257
- 16. Badurdeen S, Kamlin COF, Rogerson SR, Kane SC, Polglase GR, Hooper SB, et al. Lung ultrasound during newborn resuscitation predicts the need for surfactant therapy in very- and extremely preterm infants. Resuscitation. 2021;162:227–235. pmid:33548362
- 17. De Martino L, Yousef N, Ben-Ammar R, Raimondi F, Shankar-Aguilera S, De Luca D. Lung Ultrasound Score Predicts Surfactant Need in Extremely Preterm Neonates. Pediatrics. 2018;142(3). pmid:30108142
- 18. Gregorio-Hernandez R, Arriaga-Redondo M, Perez-Perez A, Ramos-Navarro C, Sanchez-Luna M. Lung ultrasound in preterm infants with respiratory distress: experience in a neonatal intensive care unit. European Journal of Pediatrics. 2020;179(1):81–89. pmid:31655870
- 19. Kayki G, Yigit S, Tandircioglu UA, Celik HT, Yurdakok M. Lung ultrasound (LUS) and surfactant treatment: looking for the best predictive moment. J Perinatol. 2021;41(7):1669–1674. pmid:33758395
- 20. Perri A, Riccardi R, Iannotta R, Di Molfetta DV, Arena R, Vento G, et al. Lung ultrasonography score versus chest X-ray score to predict surfactant administration in newborns with respiratory distress syndrome. Pediatr Pulmonol. 2018;53(9):1231–1236. pmid:29870158
- 21. Perri A, Tana M, Riccardi R, Iannotta R, Giordano L, Rubortone SA, et al. Neonatal lung ultrasonography score after surfactant in preterm infants: A prospective observational study. Pediatric Pulmonology. 2020;55(1):116–121. pmid:31710177
- 22. Perri A, Sbordone A, Patti ML, Nobile S, Tirone C, Giordano L, et al. Early lung ultrasound score to predict noninvasive ventilation needing in neonates from 33 weeks of gestational age: A multicentric study. Pediatric Pulmonology. pmid:35670034
- 23. Raimondi F, Migliaro F, Corsini I, Meneghin F, Pierri L, Salome S, et al. Neonatal Lung Ultrasound and Surfactant Administration A Pragmatic, Multicenter Study. Chest. 2021;160(6):2178–2186. pmid:34293317
- 24. Raschetti R, Yousef N, Vigo G, Marseglia G, Centorrino R, Ben-Ammar R, et al. Echography-Guided Surfactant Therapy to Improve Timeliness of Surfactant Replacement: A Quality Improvement Project. Journal of Pediatrics. 2019;212:137–143.e1. pmid:31079857
- 25. Rodriguez-Fanjul J, Jordan I, Balaguer M, Batista-Munoz A, Ramon M, Bobillo-Perez S. Early surfactant replacement guided by lung ultrasound in preterm newborns with RDS: the ULTRASURF randomised controlled trial. European Journal of Pediatrics. 2020;179(12):1913–1920. pmid:32710304
- 26. Vardar G, Karadag N, Karatekin G. The Role of Lung Ultrasound as an Early Diagnostic Tool for Need of Surfactant Therapy in Preterm Infants with Respiratory Distress Syndrome. Am J Perinatol. 2021;38(14):1547–1556. pmid:32674204
- 27. Hutton B, Salanti G, Caldwell DM, Chaimani A, Schmid CH, Cameron C, et al. The PRISMA extension statement for reporting of systematic reviews incorporating network meta-analyses of health care interventions: checklist and explanations. Ann Intern Med. 2015;162(11):777–84. pmid:26030634
- 28. Luo Keren TJ. High-flow nasal cannula versus continuous positive airway pressure for primary respiratory support in preterm infants: A systematic Review and Meta-analysis. 2022.
- 29. Sakonidou S, Dhaliwal J. The management of neonatal respiratory distress syndrome in preterm infants (European Consensus Guidelines—2013 update). Arch Dis Child Educ Pract Ed. 2015;100(5):257–9. pmid:25694422
- 30. Sweet DG, Carnielli V, Greisen G, Hallman M, Ozek E, Plavka R, et al. European Consensus Guidelines on the Management of Respiratory Distress Syndrome—2016 Update. Neonatology. 2017;111(2):107–125. pmid:27649091
- 31. Razak A, Faden M. Neonatal lung ultrasonography to evaluate need for surfactant or mechanical ventilation: a systematic review and meta-analysis. Arch Dis Child Fetal Neonatal Ed. 2020;105(2):164–171. pmid:31248960
- 32. Capasso L, Pacella D, Migliaro F, Salomè S, Grasso F, Corsini I, et al. Can lung ultrasound score accurately predict surfactant replacement? A systematic review and meta-analysis of diagnostic test studies. Pediatr Pulmonol. 2023;58(5):1427–1437. pmid:36717970