Abstract
Introduction
The prevalence of catheter-associated bloodstream infections (CLABSI) is high and is a severe health problem associated with an increase in mortality and elevated economic costs. There are discrepancies related to the risk factors of CLABSI since the results published are very heterogeneous and there is no synthesis in the description of all the predisposing factors.
Objective
We aimed to perform a systematic review and meta-analysis to synthesize and establish the risk factors predisposing to CLABSI reported in the literature.
Method
This is a systematic review of observational studies following the PRISMA recommendations. MEDLINE and CINAHL databases were searched for primary studies from 2007 to 2021. The protocol was registered in PROSPERO CRD42018083564.
Results
A total of 654 studies were identified, 23 of which were included in this systematic review. The meta-analysis included 17 studies and 9 risk factors were analyzed (total parenteral nutrition (TPN), chemotherapy, monolumen and bilumen catheters, days of catheterization, immunosuppression, kidney disease and diabetes mellitus) due to the homogeneity of their definitions and measurements. The risk factors found to increase the probability of developing CLABSI were TPN, multilumen devices, chemotherapy treatment, immunosuppression and the number of days of catheterization. On the other hand, monolumen devices presented a lower likelihood of triggering this infection.
Citation: Lafuente Cabrero E, Terradas Robledo R, Civit Cuñado A, García Sardelli D, Hidalgo López C, Giro Formatger D, et al. (2023) Risk factors of catheter- associated bloodstream infection: Systematic review and meta-analysis. PLoS ONE 18(3): e0282290. https://doi.org/10.1371/journal.pone.0282290
Editor: Ahmet Murt, Istanbul University-Cerrahpasa, Cerrahpasa Medical Faculty, TURKEY
Received: November 30, 2021; Accepted: February 13, 2023; Published: March 23, 2023
Copyright: © 2023 Lafuente Cabrero et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the manuscript and its Supporting information files.
Funding: The author ELC has received a research grant from Becton Dickinson S.A. The funding reference for the grant from Becton Dickinson S.A given to the doctoral thesis project of ELC is MS-01702-2019-02-12/FIMIM 12773. Only the doctoral thesis project of ELC was the receptor of this grant through the Grupo de Investigación de Cuidados Enfermeros (GRECI) of the Instituto Municipal de Investigación Médica (IMIM). The URL of Becton Dickinson S.A is: https://www.bd.com/es-es. Becton Dickinson S.A has had no role in the design of the study, data collection or analysis or in the preparation of the manuscript and will not know the results until publication.
Competing interests: The authors have no conflict of interest.
1. Introduction
The use of central venous catheters (CVCs) has increased in current medical practice and is widely used in hospitalized patients [1, 2]. Safe administration of different medications and use by nursing teams is ensured by advances in the technology of these devices and insertion techniques, among others. However, despite the multiple benefits, CVCs are also associated with (central line)-associated bloodstream infections (CLABSI) [3–6].
In the United States 80,000 episodes of CLABSI are diagnosed annually and are associated with increased mortality and elevated economic costs (39,000 US dollars per episode) [7]. Despite including CLABSI in the Bacteremia 0 program and in nosocomial infection surveillance programs in Catalonia (VINCAT) or the Study of the Prevalence of Nosocomial Infections in Spain (EPINE), the rates of CLABSI remain elevated in our country [8]. According to EPINE, 45.80% of nosocomial bacteremias are secondary to a vascular device, with central venous access devices and peripherally inserted central catheters (PICC) being the cause in 34.39% and 11.42% of the cases, respectively [1]. The Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) reports that the rates of CLABSI range between 15% and 30% in Spain [3]. Other international studies have reported catheter-associated infection rates of 6.3% to 23% of all nosocomial bacteremias and others describe 15.2% [9, 10]. Moreover, the high prevalence of this complication has led to it becoming one of the major causes of morbidity and mortality in hospitalized patients [5, 11]. According to SEIMC, the direct mortality attributable to bacteremia is between 12% and 25% [3, 12], with a repercussion on the health care system of a mean cost of 18,000 euros per episode, depending on the causative microorganism [13].
In addition to the high rates and severity of outcomes, many studies have described a multitude of risk factors. In 2007, one systematic review studied the risk of CLABSI based on the venous device implanted and the time in place [14]. However, this study did not evaluate other related risk factors that could increase the risk of CLABSI, such as those related to some treatments [4, 5, 15, 16], pathological history [5, 17–21] and clinical status [5, 18, 20, 22]. Thus, the results obtained in the different studies are very heterogeneous, and do not synthesize and identify all the factors that favor the appearance of CLABSI. Therefore, here we provide a systematic review and meta-analysis that synthesizes and establishes the risk factors predisposing central venous catheter-associated bacteremia described in the literature.
2. Method
2.1 Design
In accordance with the prevailing guidelines, our systematic review protocol was registered with the International Prospective Register of Systematic Reviews (PROSPERO, registration number CRD42018083564). This systematic review followed the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) [23].
2.2 Search strategy
We performed serial literature searches for articles published in MEDLINE (via PubMed) and CINAHL, from 2007 to February 25, 2021, using the following keywords: “CLABSI”, “CRBSI” “Catheter” and “Risk factor”. Boolean operators were used to enhance electronic searches. All human studies published in full-text form were eligible for inclusion, with no language restriction in the searches. Additional studies of interest were identified by hand searches of bibliographies of expert authors (Pittiruti, M and Maki, D) (S1 Text).
2.3 Study eligibility and selection criteria
Three authors (EL, AT and CE) independently determined study eligibility. Any difference in opinion regarding eligibility was resolved through consensus.
Studies were included if they: involved participants 18 years of age or older; mentioned the risk factors associated with central venous devices, whether centrally or peripherally inserted (CICC/PICC, respectively); definition of catheter- associated bacteremia according to the criteria of the Centers for Disease Control (CDC)/National Healthcare Safety Network (NHSN); studies published in the last 14 years; and the study design was randomized control trials, cohort or case-control studies. We excluded studies with patients not hospitalized during the whole study.
2.4 Definition of variables and outcomes
The primary outcome of this study was the presence of CLABSIs or (central line)-related bloodstream infection (CRBSI) in patients with CICC or PICC.
A CICC was defined as any central venous access device inserted into the internal jugular or subclavian vein. PICCs were defined as catheters inserted in the basilic, axillar, cephalic, or brachial veins of the upper extremities with tips terminating in the cavoatrial junction. CLABSI or CRBSI was defined as the occurrence of bacteremia in patients with PICCs or CICCs according to CDC /NHSN criteria [7]
2.5 Data abstraction and validity assessment
Data were extracted from the studies included with use of a standardized template designed by our group. The following information was collected from all studies: study characteristics (author, year of publication, country, study design and patient population), variables related to vascular access/device (vascular access device, CLABSI ratio), variables and potential risk factors evaluated in each study and results of multivariate analysis.
2.6 Study selection
All the studies containing abstracts and title were imported to Mendeley (version 1.19.3; Mendeley LDT, m Elsevier, London, United Kingdom). After excluding duplicate papers, three investigators (EL, AT and CE) independently screened the title and the abstract according to the inclusion and exclusion criteria. If the selection of the literature could be determined based on the criteria, the full text was further evaluated. Three investigators (EL, AT and CE) independently assessed the quality of the papers included. The grade of evidence and grade of recommendation were established according to the proposal of the Centre for Evidence-Based Medicine of Oxford [24]
2.7 Range of bias among the studies
The three authors (EL, AT and CE) independently evaluated the risk of bias.
To analyze the quality of potentially eligible articles the Strengthening the Reporting of Observational studies in Epidemiology (STROBE) [25] statement for cohort, case and control studies was followed.
2.8 Inclusion in the meta-analysis, data extraction and statistical methods
A meta-analysis was performed using the most prevalent risk factors for the presence of CLABSI included in the quantitative review (total parenteral nutrition [TPN], number of lumens, days of catheter placement, chemotherapy, immunosuppression, kidney disease and diabetes).
For the data analysis in the case of days of catheterization, mean values and their standard deviations of each study were extracted and weighted mean differences and 95% confidence intervals (CI) were used. In the case of qualitative factors, odds ratios (OR) and 95% CI were calculated for each study. The Cochrane-Q test was performed to assess the degree of heterogeneity among studies, and the I2 index (Higgins et al. 2003) [26] was used to describe the percentage of variation across studies due to heterogeneity (I2 = 25%: low; I2 = 50%: moderate; I2 = 75%: high heterogeneity). Study-specific estimates were pooled using both the fixed effect model (Mantel–Haenzel–Peto test) and the random effect model (Dersimonian-Laird test). If significant heterogeneity was found, the random effect model results were shown. To the contrary, the fixed-effect model was presented. Forest Plots were created to describe the pooled analysis. Statistical significance was defined as a P value < 0.05. All of the statistical analyses were conducted using R Studio.
3. Results
3.1 Search results
After removal of duplicates, 533 articles were identified by our electronic search. Of these, 417 were excluded on the basis of abstract information, and an additional 93 studies were discarded after full text review. Therefore, 23 studies reporting CLABSI in patients with PICCs or CICCs were included in the present systematic review. (Fig 1).
3.2 Characteristics of the studies included
Table 1 provides a detailed description of the studies analyzed. The 23 studies included were published between 2007 and 2021. Eight studies were undertaken in the United States, [4, 16,17, 20, 21, 27–29], three in Australia [30–32], two in India [18, 33], two in China [34, 35], and one in each of the following countries: Spain [36], Tunisia [19], Japan [15], France [37], Cyprus [38], Germany [22], Korea [39], and Turkey [40]. Among the studies eligible, 22 (95.65%) were cohort follow-up studies [4, 15, 17–22, 27–40] and 1 was a case-control study (4.34%) [16]. Of the studies included, 9 were performed in the Intensive Care Unit (ICU) (39.13%) [17–19, 27, 28, 30, 31, 33, 36], 10 in conventional hospitalization wards (43.47%) [4, 15, 16, 20, 21, 29, 35, 37, 38, 40] and 4 in the Oncology Department (17.39%) [22, 32, 34, 39].
All the studies specified the type of catheter used; in 9 the type of venous device used was CICC (39.13%) [17–19, 21, 28, 30, 33, 35, 40], in 5 PICC (21.73%) [4, 20, 37–39], and in 9 studies both types of devices were included (39.13%) [15, 16, 22, 27, 29, 31, 32, 34, 36].
The sample size of the studies evaluated established the catheter as the unit of analysis. In the cohort follow-up studies, the sample size ranged between 115 and 85,849 catheters, except in one study [30], which did not report the number of catheters but described rates of days of catheter placement. The only case-control study evaluated [16] included a sample of 197 cases and 207 controls.
3.3 Quality of the studies included
Analysis of the quality of the studies included was performed according to the STROBE statement [25]. The quality of the studies included was 3a and 3b. Eighteen studies obtained a grade 3a recommendation (78.26%) while 6 were 3b (21.74%). Of the latter 6 studies, one had a case-control design [16] and the 5 remaining studies [18, 19, 33, 35, 39] had a reduced sample size and did not achieve sufficient statistical power. Thus, the quality of the studies included in the review was good-regular.
3.4 Description of the risk factors
3.4.1 Demographic characteristics.
Gender was analyzed in 20 articles (89.95%), although male sex was identified as having a greater probability of CLABSI in only 1 study [27] (odds ratio [OR] 1.93; 95% confidence interval [CI] 1.02–3.68). Age was evaluated as a risk factor in 18 studies (78.26%). One study independently related age to the risk of CLABSI (OR 1.02; 95% CI 1.00–1.04) [50]. On the other hand, another study [30] demonstrated that age was a protective factor for CLABSI (relative risk [RR] = 0.94; 95% CI 0.90–0.99).
3.4.2 Pharmacotherapy administered.
Nine (39.13%) articles included the type of pharmacotherapy administered through both an inserted catheter and other administration routes as a study variable. In regard to the treatment administered through the endovenous device, one study related preventive administration of antibiotics prior to catheter insertion to the appearance of infection (OR 4.46; 95% CI 2.08–10.1) [19]. Another study related the administration of antibiotics through the endovenous device to the risk of infection (hazard ratio [HR] 2.854; 95% CI 1.082–7.530) [39]. Specifically, the administration of other drugs, such as carbapenems, was shown to be a risk factor for CRSBI (OR 6.02; 95% CI 2.29–15.83) [22]. To the contrary, the administration of glycopeptides and blood transfusions reduced the probability of catheter-associated infection (OR 0.10; 95% CI 0.03–0.34) and (OR 0.04; 95%CI 0.02–0.08), respectively [22]. The administration of chemotherapy was identified as a risk factor in different studies [4, 16, 37–39] (HR 2.39; 95% CI 1.59–3.59), (OR 7.2; 95% CI 1.8–29.6), (OR 3.36; 95%CI 1.15–9.78), (OR 8.2; 95% CI 3.4–19.9), (HR 11.421; 95% CI 2.434–53.594), respectively. Likewise, TPN was also shown to be a factor related to CLABSI in 4 articles [4, 15, 16, 21] (HR 1.82; 95% CI 1.21–2.73), (OR 12.75; 95% CI 2.48–62.26), (OR 4.33; 95% CI 2.50–7.48), (OR 2.2; 95% CI 1.2–4.0), respectively. Other factors related to CLABSI [28,37] were the administration of anticoagulants, beta-blockers and diuretics (OR 4.1; 95% CI 1.4–12.0) and (OR 1.85; 95% CI 1.04–3.29), respectively. Finally, cholesterol-reducing drugs (oral statins) were described as protective factors (OR 0.39; 95% CI 0.17–0.89) (28).
3.4.3 Interventions and care in critical patients.
One of the studies related ICU stay greater than 20 days as a factor which increased the probability of CLABSI (OR 4.80; 95% CI 1.69–13.62) [33]. Another article described the relation which both invasive mechanical ventilation (IMV) and non-invasive mechanical ventilation have with CLABSI (RR 1.14; 95% CI 1. 08–1.21) and (RR 1.01; 95% CI 1.01–1.02), respectively [30]. However, in the same study, IMV during the first 24 hours reduced the probability of developing CLABSI (RR 0.85; 95% CI 0.77–0.94). Only one study identified tracheostomy as a risk factor for CLABSI (OR 2.3; 95% CI 1.17–4.54) [36]. In the critical surgical setting, two studies reported that emergency surgery by laparotomy increased the probability of presenting CLABSI (OR 1.92; CI 95% 1.02–3.61) [27] and (OR 3.96; 95% CI 1.01–15.51) [35], and reopening was also considered a risk factor (OR 2.08; 95% CI 1.10–3.94) [27].
3.4.4 Analytical indicators.
Four studies evaluated the presence of immunological factors related to the risk of CLABSI, with two studies [18, 20] identifying immunosuppression as a risk factor (OR 10.5; 95% CI 1.58–70.02) and (OR 2.60; 95% CI 1.45–4.67), respectively. A third study related immunodeficiency to the appearance of CLABSI (OR 2.26; 95% CI 1.70–3.00) [21].
Autologous/allogenic hematopoietic stem cell transplantation showed a relationship with catheter-related infection (OR 6.0; 95% CI 1.2–29.3) [37]. Likewise, leucopenia also demonstrated a relationship with CLABSI (OR 69.77; 95% CI 15.76–308.86) [22].
On the other hand, three studies [4, 33, 38] reported that the presence of some microorganisms in different contexts increased the likelihood of developing CLABSI. Colonization-infection by Clostridium difficile (OR 2.25; 95% CI 1.17–4.33) [38], a history of CLABSI during the three months prior to new device placement (HR 2.84; 95% CI 1.68–4.80) [4] and sepsis of the exit-site (OR 4.61; 95% CI 1.43–14.78) and (OR 3.80; 95% CI 1.91–7.87) [19, 33] were independently related to CLABSI.
3.4.5 Comorbidities.
A higher score in the Acute Physiology and Chronic Health Disease Classification System (APACHE III) scale increased the probability of catheter-related sepsis (RR 1.03; 95% CI 1.01–1.06) [30], and coagulopathy was independently related to the appearance of CLABSI (HR 1.65; 95% CI 1.17–2.30) [17]. In addition, in the latter study other factors related to infection were identified: paralysis of the extremity carrying the device (HR 1.76; 95% CI 1.06–2.93) and weight loss (HR 1.56; 95% CI 1.12–2.19). Acute myocardial infarction was also found to be related to CLABSI (OR 0.28; 95% CI 0.1–0.76) [28].
Kidney disease was independently related to CRSBI in three studies (HR 1.59; 95% CI 1.13–2.22) [17], (OR 1.88; 95% CI 1.16–3.05) [28] and (OR 2.79; 95% CI 2.00–3.88) [21]. Pulmonary disease and acute myeloid leukemia were also related to the appearance of CLABSI in one study (OR 3.17; 95% CI 1.32–7.62) (OR 2.72; 95% CI 1.43–5.17), respectively [22]. In addition, two publications identified the presence of hematologic neoplastic disease as a risk factor (HR 3.07; 95% CI 1.18–8.03) [32] and (HR 3.77; 95% CI 2.75–5.16) [4]. In the case of diabetes, on one hand, in one study it was described as a risk factor (OR 2.43; 95% CI 1.09–5.7) [19] while in another study diabetes had a protector effect (OR 0.63; 95% CI 0.45–0.88) [21].
3.4.6 Catheter.
With regard to catheter-related variables, one study showed that replacing the catheter through a guideline increased the probability of developing catheter infection (OR 4.59; 95% CI 2.28–9.3) [36]. The number of lumens was also related to the appearance of CLABSI in five studies [4, 20, 29, 38, 39], showing that the greater the number of lumens the greater the likelihood of developing infection (HR 2.09; 95% CI 1.49–2.92), (OR 3.26; 95% CI 1.09–9.72), (OR 2.87; 95% CI 1.39–5.92) (HR 8.52; 95% CI 2.55–28.49), and (HR 5.466; 95% CI 1.257–23.773), respectively. The synchronic presence of other venous devices also influenced the appearance of infection (HR 1.98; 95% CI 1.40–2.80) [4] and (OR 3.4; 95% CI 1.7–6.9) [16], (OR 7.08; 95% CI 2.95–17) [22]. On the other hand, the latter study also demonstrated that insertion into the subclavian vein had a protective effect (OR 0.32; 95% CI 0.14–0.77) [22]. Other protective factors reported included ultrasound-guided insertion (RR 0.47; 95% CI 0.34–0.64) [30], correct positioning of the distal point in the lower third of the superior vena cava (OR 0.34; 95% CI 0.2–0.51) [34] and an adhesive fixation system (OR 0.55; 95% CI 0.32–0.94) [34].
3.4.7 Temporality.
According to the results of four studies, the duration of device implantation had an impact on the appearance of catheter-related bacteremia, being one of the variables most frequently studied and showing the greatest number of significant results (OR 1.028; 95% CI 1.0009–1.048) [36], (OR 1.04; 95% CI 1.03–1.06) [28], (OR 5.52; 95% CI 1.8–16.1) [18], (OR 1.95; 95% CI 1.21–2.13) [19], (OR 1.08; 95% CI 1.04–1.13) [35], (OR 1.02; 95% CI 1.00–1.04) [40]. Two studies related the length of ICU stay to the appearance of CLABSI, with one showing that a stay longer than 7 days increased the probability of the infection and the second determined that a stay greater than 20 days was a factor related to infection (OR 4.80; 95% CI 1.69–13.62) [33] and (OR 2.07; 95% CI 1.06–4.04) [31].
3.4.8 Microbiology.
Microbiological results were reported in 14 (60.8%) of the studies included in this systematic review. In 11 studies Gram-positive microorganisms were isolated: in 9 studies [20, 22, 29, 32,34–36, 38, 40] coagulase-negative Staphylococci were described as the most prevalent, with 4 identifying S. epidermidis [22, 32, 34, 38]. In another study, the most prevalent microorganism was S. aureus [33] and lastly, Enterobacter spp. [31]. In 4 studies [18, 19, 31, 39] Gram-negative bacilli were described as the most prevalent (Enterobacter spp., Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa). Finally, Candida spp. was also isolated [31, 35, 39]. Some studies were cited twice because both microorganisms were isolated with the same prevalence.
3.5 Synthesis of the results
Among the 23 studies included, 17 were included in the meta-analysis [4, 15, 16–21, 28, 29, 33, 35–40]. The reasons for excluding six articles were: 1) the remaining risk factors were not defined or measured in the same way and did not allow for conclusive statistical tests, 2) they had not been analyzed in more than one study, and 3) the results of the studies did not show significance in the analyses performed. A total of 9 risk factors were identified and included in the meta-analysis due to the homogeneity of the definitions and measurements: administration of TPN, single, bilumen, or multilumen catheters (including trilumen, tetralumen and pentalumen catheters in the latter group), days of catheterization, chemotherapy, immunosuppression, kidney disease and diabetes mellitus.
The results showed that patients not receiving TPN had a lower probability of having CLABSI (OR = 0.48; 95% CI: 0.35–0.65, p <0.001, heterogeneity I2 = 47%) [4, 15, 16, 19, 21, 29, 36, 37, 39, 40] (Fig 2).
Likewise, patients who did not undergo chemotherapy presented a lower probability of developing this complication (OR 0.33; 95% CI: 0.20–0.54, p<0.0001 heterogeneity I2 = 68%) [4, 16, 20, 29, 37–39] (Fig 3).
Absence of immune system compromise secondary to treatment or some type of disease was also related to being a protector factor against CLABSI (OR 0.44; 95% CI: 0.24–0.82, p = 0.01, heterogeneity I2 = 66%) [18, 20, 21, 36] (Fig 4).
Being a carrier of a CVC with more than one lumen implied a greater risk of CLABSI (OR = 2.74; 95% CI: 1.84–4.07, p = 0.02, heterogeneity I2 = 60%) [4, 20, 29, 36–39] (Fig 5).
On the other hand, bilumen devices analyzed in 7 articles [20, 29, 36–40] were not related to the appearance of CLABSI (OR 0.78; 95% CI: 0.51–1.19, p = 0.25, heterogeneity I2 = 67%) (Fig 6).
Lastly, it was observed that not having a multilumen catheter reduced the probability of CLABSI (OR 0.45; 95% CI: 0.37–0.55, p<0.001, heterogeneity I2 = 0%) [(4, 20, 29, 33, 36–38, 40] (Fig 7).
With regard to the number of days with a catheter, it was found that patients catheterized for a greater number of days had a higher likelihood of developing CLABSI (OR 6.43; 95% CI: 10.75–2.12, p = 0.003, heterogeneity I2 = 89%) [15, 19, 21, 29] (Fig 8).
Lastly, kidney disease was included in a total of 6 articles [4, 17, 21, 29, 33, 38] and showed no relationship with CLABSI (OR 0.63; 95% CI: 0.35–1.12, p = 0.12, heterogeneity I2 = 90%) (Fig 9).
Likewise, neither was diabetes related to infection [4,17–21, 29, 33, 36, 38, 40] (OR 1.08; 95% CI: 0.94–1.25, p = 0.27 heterogeneity I2 = 41%) (Fig 10).
3.6 Individual biases
3.6.1.
The biases of publication and measurement were cited in 1 or the 23 studied included [31]. The variability in the insertion, management and treatment of CRSBI related to the bias of classification was observed in 3 of the 23 studies evaluated [31, 32, 36]. A bias of detection related to the variability in the definition and measurement of CLABSI was observed in 7 studies [4, 17, 19, 22, 32, 33, 38], and selection bias was detected in 12 studies [4, 16, 18–20, 22, 28–30, 34, 38, 39]. A bias of notification due to missing data during the data collection process was recognized in 12 studies [16, 17, 38, 39, 19–22, 28, 29, 36, 37]. Some studies had a reduced sample size implying a low statistical power in the analysis of some of the risk factors [16, 18, 28, 33]. Finally, 4 studies did not report any limitation [15, 27, 35, 40].
3.6.2.
This review has several limitations which are implicit in the studies included in the meta-analysis. Specifically, there was significant heterogeneity in the general results mainly derived from the data belonging to the risk factors of TPN, unilumen and bilumen catheters, days of catheterization, chemotherapy, kidney disease, diabetes and immunosuppression, which were attributed a high-moderate heterogeneity >25%. This heterogeneity could be related to the clinical diversity, sample size and variability of the results since they are very important variables which could explain the heterogeneity of the data as a whole. However, one of the variables studied presented a low heterogeneity < 25% (multilumen catheter) and, thus, may be attributed to very solid results with excellent homogeneity.
4. Discussion
The prevention of CLABSI is problematic, with severe clinical repercussions at an individual and organizational level, since the use of venous devices in the hospital setting is a transversal intervention that affects hospitalized, critical, and oncological patients alike. The different studies published show contradictory results and, therefore, the present review has focused on identifying and synthesizing the variables related to the appearance of CLABSI. The results indicate that TPN, multilumen devices, chemotherapy treatment, immune system compromise and the length of catheterization are risk factors for CLABSI. On the other hand, monolumen devices present a lower probability of triggering this infection.
Multiple studies established TPN as a risk factor of CLABSI. The guidelines of the American Society for Parenteral and Enteral Nutrition (ASPEN) and CDC relate TPN with the risk of CLABSI due to the preference of the microorganisms for dextrose [7, 41]. However, ASPEN related other nutritional factors, such as a deficient nutritional status conditioning immune response to the risk of infection. Along the same line, another study corroborated that a state of malnutrition and hypoalbuminemia was associated with CLABSI (OR 3.13; 95% CI 1.38–5.24, p<0.05) [42]. Other studies determined that the risk of CLABSI is dependent on the duration of catheterization and the length of TPN [43, 44]. In addition, it has been shown that manipulation of venous devices and TPN by health care professionals may condition the appearance of CLABSI and should be manipulated with maximum precaution of sterile barriers [7]. Nonetheless, the studies included in this review coincide in establishing TPN as a risk factor, but it should be noted that one study [29] found no association between these two factors, perhaps secondary to the creation of a strategy of bundle manipulation/care/approaches that reduce the appearance of the problem. Therefore, the result of TPN as a risk factor should be interpreted with caution since the factors described could be factors independently related to CLABSI.
Chemotherapy has shown to be an independent factor of CLABSI, but as described in the literature, the cause of this association could be because of the vulnerability of developing any infectious process due to the neutropenia induced by cytostatic drugs [45, 46]. In addition, this study shows that a state of immunosuppression is an independent factor of CLABSI due to immune system dysfunction [13, 47, 48]. However, the studies included in this review did not report whether the cause of the immunosuppression was secondary to a hematological disease, organ transplantation, autoimmune disease or acquired immunodeficiency, and thus, it is not possible to stratify the results based on the causative disease. On the other hand, the results of the meta-analysis identified immunosuppression as an independent risk factor, except in one study due to the reduced sample size [18].
In relation to the number of lumens of the venous devices, multilumen catheters were found to be an individual risk factor of CLABSI. These results coincide with the CDC recommendation (category IB) of implanting devices with the least number of lumens, since the microorganisms reach the catheter through the connections and with these devices the risk is higher due to the greater number of entries [7]. In addition, these devices are susceptible to greater manipulation, hindering adequate disinfection and device maintenance. However, multilumen catheters are indicated in patients with high pharmacologic requirements in whom it is not considered safe to reduce the number of lumens because of the risk of pharmacological interaction [49]. In these cases, the importance of the management and maintenance of these devices is important to note. Along this line, it has been demonstrated that the impregnation of lumens with antimicrobial substances reduces the risk of CLABSI [50].
The present review established that monolumen venous devices are a protective factor; however, a meta-analysis determined that there are no differences when high quality studies with homogeneous samples are analyzed [51]. Therefore, this contradiction among studies could also be related to the quality of management, care and adherence to guidelines by the professionals manipulating these devices [52].
In the case of days of catheterization, the studies included showed elevated heterogeneity in the results. Taking into account that the CDC has established that routine replacement of central devices is not necessary (category IB) [45], it seems that the real reason for the development of infection may be the deterioration and dysfunctionality which venous devices acquire by multiple manipulations over time. Previous studies have shown that the quality of catheter care and management is key in the colonization of these devices [52], with thrombosis and intraluminal and extraluminal fibrin favoring the growth of microorganisms [53].
Infection is the second cause of death in patients with kidney disease receiving hemodialysis therapy [54]. These patients live with precursor risk factors of CLABSI of different causes, such as immune compromise, being carriers of a vascular access for renal replacement therapies, resistance to antibiotics, comorbidities such as diabetes, and colonization by nasal Staphylococcus aureus which promote the risk of this infection [55]. However, there are discrepancies among the results obtained in the literature, and our study did not describe any association with catheter-related infection and kidney disease. This may be justified in that the concept of kidney disease is very wide, and all the patients with this disease present very different characteristics which may generate very heterogeneous and inconclusive results. In addition, the CDC states that correct manipulation of a vascular device and correct monitoring by professionals is the main intervention for the prevention of CLABSI [56]. This indicates that depending on the preventive measures applied at an institutional level, having kidney disease is a precursor risk factor for the development of CLABSI.
In our meta-analysis, diabetes was not determined to be an independent risk factor of CLABSI. However, in the literature a relationship has been described between this disease and compromise of immune response [57], which would explain the results of some studies which establish diabetes as a related factor [55]. The discordance of our results with others may be due to the fact that most of the studies included did not take into account the type of diabetes, the complexity of this disease, the treatment or the years of evolution, which could justify the heterogeneity in the results obtained.
In relation to the microbiological results, the most frequent microorganisms isolated were Gram-positive cocci, the most prevalent being coagulase-negative Staphylococci, thereby indicating a possible colonization by skin flora of the patient or secondary to manipulation of the device by different health care professionals. Other series of CLABSI in our setting showed the same trend [58, 59]. However, one study performed in the United States described Enterobacter spp. and Candida spp. as the most prevalent and concluded that more evidence is necessary to establish why the patients are at risk of presenting CLABSI by these microorganisms to thereby develop preventive measures aimed at these microorganisms [60]. Despite the improvements implemented in recent years, the results demonstrate that studies should be focused not only on strategies of insertion but also on the management and maintenance of venous catheters.
The main limitation of this review is the long interval of time in the inclusion of the articles which may increase the heterogeneity of some of the variables (days of catheterization). Another limitation is that the quality of the studies was good-regular, despite not including any randomized study, and this did not allow the establishment of cause-effect relationship. One other limitation is that the quality of the maintenance of venous devices is a very important factor for the appearance of CLABSI, and its evaluation is difficult to measure and may induce overestimation of the effect of other variables of catheter-related infection. Another aspect to take into account is the elevated heterogeneity based on the variable analyzed. In addition, the large number of variables that can be analyzed as potential related factors are always subject to changes, modifications and extensions of risk factors predisposing to CLABSI, since there are other risk factors not considered in the articles included for analysis that may be related to the appearance of CLABSI. Finally, the last limitation is related to the microbiological results since we were unable to synthetize the results reported in these studies because some are described in real numbers while others are indicated in percentages, and some studies report the species and others the genus.
Despite these limitations, this review also has great strengths such as the meta-analysis which provided a synthesis of the results obtained to date and their clinical applicability.
Robust identification of risk factors may be useful for their inclusion in algorithms for deciding the most adequate venous device, in addition to the variables of pharmacotherapy and venous accesses available. It also allows including therapeutic strategies based on rigorous measures of asepsis with the aim of preventing and reducing the incidence of CLABSI, especially in patients with some of the present risk factors.
5. Conclusions
The decision to insert a venous device should be made based on individual evaluation of risk factors for the development of CLABSI since this complication can involve very severe clinical repercussions with very elevated health care costs. Well-designed studies with homogeneous patient samples are needed to increase the quality of the results and help evaluate the efficacy of these devices as well as the clinical benefits and profitability of the therapeutic strategies implemented.
References
- 1.
Sociedad Española de Medicina Preventiva, Salud Pública Higiene [Sede Web]. Estudio de Prevalencia de las infecciones Nosocomiales en España. EPINE-EPPS 2017 [Acceso: 1/1/ 2020]; Disponible en: http://hws.vhebron.net/epine/Global/EPINE%20EPPS%202017%20Informe%20Global%20de%20Espa%C3%B1a%20Resumen.pdf
- 2. Climo M, Diekema D, Warren DK, Herwaldt LA, Perl TM, Peterson L, et al. Prevalence of the use of central venous access devices within and outside of the intensive care unit: results of a survey among hospitals in the prevention epicenter program of the Centers for Disease Control and Prevention. Infect Control Hosp Epidemiol. 2003 Dec;24(12):942–5. pmid:14700410
- 3. Chaves F, Garnacho-Montero J, Del Pozo JL, Bouza E, Capdevila JA, de Cueto M, et al. Diagnosis and treatment of catheter-related bloodstream infection: Clinical guidelines of the Spanish Society of Infectious Diseases and Clinical Microbiology and (SEIMC) and the Spanish Society of Spanish Society of Intensive and Critical Care Medicine. Med intensiva. 2018;42(1):5–36.
- 4. Herc E, Patel P, Washer LL, Conlon A, Flanders SA, Chopra V. A Model to Predict Central-Line-Associated Bloodstream Infection Among Patients With Peripherally Inserted Central Catheters: The MPC Score. Infect Control Hosp Epidemiol. 2017 Oct;38(10):1155–66. pmid:28807074
- 5. Buetti N, Marschall J, Drees M, Fakih MG, Hadaway L, Maragakis LL, et al. Strategies to prevent central line-associated bloodstream infections in acute-care hospitals: 2022 Update. Infect Control Hosp Epidemiol [Internet]. 2022 May 19 [cited 2022 Oct 28];43(5):553–69. Available from: https://pubmed.ncbi.nlm.nih.gov/35437133/
- 6.
Crnich CJ MD. Infections of vascular devices [Internet]. Cohen J PW, editor. Infectiuos Diseases. Edinburgh: Mosby; 2004 [cited 2022 Oct 28]. 629–39 p. https://books.google.com/books/about/Infectious_Diseases.html?hl=es&id=AoDAngEACAAJ
- 7. O’Grady NP, Alexander M, Burns LA, Dellinger EP, Garland J, Heard SO, et al. Guidelines for the prevention of intravascular catheter-related infections. Clin Infect Dis an Off Publ Infect Dis Soc Am. 2011 May;52(9):e162–93.
- 8. Palomar M, Álvarez-Lerma F, Riera A, Díaz MT, Torres F, Agra Y, et al. Impact of a national multimodal intervention to prevent catheter-related bloodstream infection in the ICU: the Spanish experience. Crit Care Med. 2013 Oct;41(10):2364–72. pmid:23939352
- 9. Mermel LA. Short-term Peripheral Venous Catheter-Related Bloodstream Infections: A Systematic Review. Clin Infect Dis [Internet]. 2017 Nov 15 [cited 2022 Oct 28];65(10):1757–62. Available from: https://pubmed.ncbi.nlm.nih.gov/29020252/
- 10. Tsuboi M, Hayakawa K, Mezaki K, Katanami Y, Yamamoto K, Kutsuna S, et al. Comparison of the epidemiology and microbiology of peripheral line- and central line-associated bloodstream infections. Am J Infect Control. 2019 Feb;47(2):208–10. pmid:30337129
- 11. Wisplinghoff H, Bischoff T, Tallent SM, Seifert H, Wenzel RP, Edmond MB. Nosocomial bloodstream infections in US hospitals: analysis of 24,179 cases from a prospective nationwide surveillance study. Clin Infect Dis an Off Publ Infect Dis Soc Am. 2004 Aug;39(3):309–17. pmid:15306996
- 12. Raad I, Chaftari A-M. Advances in prevention and management of central line-associated bloodstream infections in patients with cancer. Clin Infect Dis [Internet]. 2014 Nov 15 [cited 2014 Nov 4];59 Suppl 5:S340–3. Available from: http://www.ncbi.nlm.nih.gov/pubmed/25352628
- 13. Riu M, Chiarello P, Terradas R, Sala M, Castells X, Knobel H, et al. [Economic impact of nosocomial bacteraemia. A comparison of three calculation methods]. Enferm Infecc Microbiol Clin. 2016 Dec;34(10):620–5.
- 14. Maki DG, Kluger DM, Crnich CJ. The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies. Mayo Clin Proc. 2006 Sep;81(9):1159–71. pmid:16970212
- 15. Ishizuka M, Nagata H, Takagi K, Kubota K. Total parenteral nutrition is a major risk factor for central venous catheter-related bloodstream infection in colorectal cancer patients receiving postoperative chemotherapy. Eur Surg Res Eur Chir Forschung Rech Chir Eur. 2008;41(4):341–5.
- 16. Concannon C, van Wijngaarden E, Stevens V, Dumyati G. The effect of multiple concurrent central venous catheters on central line-associated bloodstream infections. Infect Control Hosp Epidemiol. 2014 Sep;35(9):1140–6. pmid:25111922
- 17. Jackson SS, Leekha S, Magder LS, Pineles L, Anderson DJ, Trick WE, et al. The Effect of Adding Comorbidities to Current Centers for Disease Control and Prevention Central-Line-Associated Bloodstream Infection Risk-Adjustment Methodology. Infect Control Hosp Epidemiol. 2017 Sep;38(9):1019–24. pmid:28669363
- 18. Mishra SB, Misra R, Azim A, Baronia AK, Prasad KN, Dhole TN, et al. Incidence, risk factors and associated mortality of central line-associated bloodstream infections at an intensive care unit in northern India. Int J Qual Heal care J Int Soc Qual Heal Care. 2017 Feb;29(1):63–7. pmid:27940521
- 19. Hajjej Z, Nasri M, Sellami W, Gharsallah H, Labben I, Ferjani M. Incidence, risk factors and microbiology of central vascular catheter-related bloodstream infection in an intensive care unit. J Infect Chemother Off J Japan Soc Chemother. 2014 Mar;20(3):163–8.
- 20. Baxi SM, Shuman EK, Scipione CA, Chen B, Sharma A, Rasanathan JJK, et al. Impact of postplacement adjustment of peripherally inserted central catheters on the risk of bloodstream infection and venous thrombus formation. Infect Control Hosp Epidemiol. 2013 Aug;34(8):785–92. pmid:23838218
- 21. Ippolito P, Larson EL, Furuya EY, Liu J, Seres DS. Utility of Electronic Medical Records to Assess the Relationship Between Parenteral Nutrition and Central Line-Associated Bloodstream Infections in Adult Hospitalized Patients. JPEN J Parenter Enteral Nutr. 2015 Nov;39(8):929–34. pmid:24898208
- 22. Baier C, Linke L, Eder M, Schwab F, Chaberny IF, Vonberg R-P, et al. Incidence, risk factors and healthcare costs of central line-associated nosocomial bloodstream infections in hematologic and oncologic patients. PLoS One. 2020;15(1):e0227772. pmid:31978169
- 23. Hutton B, Catalá-López F, Moher D. La extensión de la declaración PRISMA para revisiones sistemáticas que incorporan metaanálisis en red: PRISMA-NMA. Med Clin (Barc). 2016;147(6):262–6.
- 24.
Oxford Centre for Evidence-Based Medicine: Levels of Evidence (March 2009)—Centre for Evidence-Based Medicine (CEBM), University of Oxford [Internet]. [cited 2022 Oct 28]. https://www.cebm.ox.ac.uk/resources/levels-of-evidence/oxford-centre-for-evidence-based-medicine-levels-of-evidence-march-2009
- 25. Vandenbroucke JP, von Elm E, Altman DG, Gøtzsche PC, Mulrow CD, Pocock SJ, et al. Strengthening the Reporting of Observational Studies in Epidemiology (STROBE): explanation and elaboration. Int J Surg. 2014 Dec;12(12):1500–24. pmid:25046751
- 26. Higgins JPT, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ. 2003 Sep;327(7414):557–60. pmid:12958120
- 27. Lissauer ME, Leekha S, Preas MA, Thom KA, Johnson SB. Risk factors for central line-associated bloodstream infections in the era of best practice. J Trauma Acute Care Surg. 2012 May;72(5):1174–80. pmid:22673242
- 28. Pepin CS, Thom KA, Sorkin JD, Leekha S, Masnick M, Preas MA, et al. Risk factors for central-line-associated bloodstream infections: a focus on comorbid conditions. Infect Control Hosp Epidemiol. 2015 Apr;36(4):479–81. pmid:25782906
- 29. Chopra V, Ratz D, Kuhn L, Lopus T, Chenoweth C, Krein S. PICC-associated bloodstream infections: prevalence, patterns, and predictors. Am J Med. 2014 Apr;127(4):319–28. pmid:24440542
- 30. Spelman T, Pilcher D V, Cheng AC, Bull AL, Richards MJ, Worth LJ. Central line-associated bloodstream infections in Australian ICUs: evaluating modifiable and non-modifiable risks in Victorian healthcare facilities. Epidemiol Infect. 2017 Oct;145(14):3047–55. pmid:28868995
- 31. Wong SW, Gantner D, McGloughlin S, Leong T, Worth LJ, Klintworth G, et al. The influence of intensive care unit-acquired central line-associated bloodstream infection on in-hospital mortality: A single-center risk-adjusted analysis. Am J Infect Control. 2016 May;44(5):587–92. pmid:26874406
- 32. Mollee P, Jones M, Stackelroth J, van Kuilenburg R, Joubert W, Faoagali J, et al. Catheter-associated bloodstream infection incidence and risk factors in adults with cancer: a prospective cohort study. J Hosp Infect. 2011 May;78(1):26–30. pmid:21459476
- 33. Kaur M, Gupta V, Gombar S, Chander J, Sahoo T. Incidence, risk factors, microbiology of venous catheter associated bloodstream infections—a prospective study from a tertiary care hospital. Indian J Med Microbiol. 2015;33(2):248–54. pmid:25865976
- 34. Gao Y, Liu Y, Ma X, Wei L, Chen W, Song L. The incidence and risk factors of peripherally inserted central catheter-related infection among cancer patients. Ther Clin Risk Manag. 2015;11:863–71. pmid:26045668
- 35. Wu S, Ren S, Zhao H, Jin H, Xv L, Qian S, et al. Risk factors for central venous catheter-related bloodstream infections after gastrointestinal surgery. Am J Infect Control. 2017 May;45(5):549–50. pmid:28233571
- 36. Garnacho-Montero J, Aldabó-Pallás T, Palomar-Martínez M, Vallés J, Almirante B, Garcés R, et al. Risk factors and prognosis of catheter-related bloodstream infection in critically ill patients: a multicenter study. Intensive Care Med. 2008 Dec;34(12):2185–93. pmid:18622596
- 37. Bouzad C, Duron S, Bousquet A, Arnaud F-X, Valbousquet L, Weber-Donat G, et al. Peripherally Inserted Central Catheter-Related Infections in a Cohort of Hospitalized Adult Patients. Cardiovasc Intervent Radiol. 2016 Mar;39(3):385–93. pmid:26202391
- 38. Pongruangporn M, Ajenjo MC, Russo AJ, McMullen KM, Robinson C, Williams RC, et al. Patient- and device-specific risk factors for peripherally inserted central venous catheter-related bloodstream infections. Infect Control Hosp Epidemiol. 2013 Feb;34(2):184–9. pmid:23295565
- 39. Lee JH, Kim MU, Kim ET, Shim DJ, Kim IJ, Byeon JH, et al. Prevalence and predictors of peripherally inserted central venous catheter associated bloodstream infections in cancer patients: A multicentre cohort study. Medicine (Baltimore). 2020 Feb;99(6):e19056. pmid:32028425
- 40. Bekçibaşi M, Dayan S, Aslan E, Kortak MZ, Hoşoğlu S. Risk factors for central venous catheter-related bloodstream infections. Le Infez Med. 2019 Sep;27(3):258–65. pmid:31545769
- 41. McClave SA, Taylor BE, Martindale RG, Warren MM, Johnson DR, Braunschweig C, et al. Guidelines for the Provision and Assessment of Nutrition Support Therapy in the Adult Critically Ill Patient: Society of Critical Care Medicine (SCCM) and American Society for Parenteral and Enteral Nutrition (A.S.P.E.N.). JPEN J Parenter Enteral Nutr. 2016 Feb;40(2):159–211. pmid:26773077
- 42.
Requena J. Hipoalbuminemia como factor de riesgo asociado a infección de catéter venoso central en pacientes en hemodialisis del Hospital Víctor Lazarte Echegaray [Internet]. Universidad privada Antenor Orrego Facultad de Medicina Humana; 2014. https://repositorio.upao.edu.pe/bitstream/20.500.12759/500/1/REQUENA_JAVIER_HIPOALBUMINEMIA_CATÉTER_VENOSO.pdf
- 43. Ocón Bretón MJ, Mañas Martínez AB, Medrano Navarro AL, García García B, Gimeno Orna JA. [Risk factors for catheter-related bloodstream infection in non-critical patients with total parenteral nutrition]. Nutr Hosp [Internet]. 2013 [cited 2014 Dec 23];28(3):878–83. Available from: http://www.ncbi.nlm.nih.gov/pubmed/23848115
- 44. Yilmaz G, Koksal I, Aydin K, Caylan R, Sucu N, Aksoy F. Risk factors of catheter-related bloodstream infections in parenteral nutrition catheterization. JPEN J Parenter Enteral Nutr. 2007;31(4):284–7. pmid:17595436
- 45. Page J, Tremblay M, Nicholas C, James TA. Reducing Oncology Unit Central Line-Associated Bloodstream Infections: Initial Results of a Simulation-Based Educational Intervention. J Oncol Pract. 2016 Jan;12(1):e83–7. pmid:26443839
- 46. Kasi PM, Grothey A. Chemotherapy-Induced Neutropenia as a Prognostic and Predictive Marker of Outcomes in Solid-Tumor Patients. Drugs. 2018 May;78(7):737–45. pmid:29754293
- 47. Tunkel AR, Sepkowitz KA. Infections caused by viridans streptococci in patients with neutropenia. Clin Infect Dis an Off Publ Infect Dis Soc Am. 2002 Jun;34(11):1524–9. pmid:12015700
- 48. Freifeld AG, Bow EJ, Sepkowitz KA, Boeckh MJ, Ito JI, Mullen CA, et al. Clinical practice guideline for the use of antimicrobial agents in neutropenic patients with cancer: 2010 update by the infectious diseases society of america. Clin Infect Dis an Off Publ Infect Dis Soc Am. 2011 Feb;52(4):e56–93.
- 49. Gorski LA, Hadaway L, Hagle ME, Broadhurst D, Clare S, Kleidon T, et al. Infusion Therapy Standards of Practice, 8th Edition. J Infus Nurs Off Publ Infus Nurses Soc. 2021;44(1S Suppl 1):S1–224. pmid:33394637
- 50. Liu H, Liu H, Deng J, Chen L, Yuan L, Wu Y. Preventing catheter-related bacteremia with taurolidine-citrate catheter locks: a systematic review and meta-analysis. Blood Purif. 2014;37(3):179–87. pmid:24777144
- 51. Dezfulian C, Lavelle J, Nallamothu BK, Kaufman SR, Saint S. Rates of infection for single-lumen versus multilumen central venous catheters: a meta-analysis. Crit Care Med. 2003 Sep;31(9):2385–90. pmid:14501971
- 52. Bell T, O’Grady NP. Prevention of Central Line-Associated Bloodstream Infections. Infect Dis Clin North Am. 2017 Sep;31(3):551–9. pmid:28687213
- 53. Rowan CM, Miller KE, Beardsley AL, Ahmed SS, Rojas LA, Hedlund TL, et al. Alteplase use for malfunctioning central venous catheters correlates with catheter-associated bloodstream infections. Pediatr Crit care Med a J Soc Crit Care Med World Fed Pediatr Intensive Crit Care Soc. 2013 Mar;14(3):306–9. pmid:23392362
- 54. Collins AJ, Foley RN, Gilbertson DT, Chen S-C. United States Renal Data System public health surveillance of chronic kidney disease and end-stage renal disease. Kidney Int Suppl. 2015 Jun;5(1):2–7. pmid:26097778
- 55. Katneni R, Hedayati SS. Central venous catheter-related bacteremia in chronic hemodialysis patients: epidemiology and evidence-based management. Nat Clin Pract Nephrol. 2007 May;3(5):256–66. pmid:17457359
- 56.
Center for desease control and prevention (CDC). CDC´s Core Intervention for Dialysis BSI Prevention [Internet]. CDC. [Sede web]. 2011 [cited 2019 Jul 29].
- 57. Trevelin SC, Carlos D, Beretta M, da Silva JS, Cunha FQ. Diabetes Mellitus and Sepsis: A Challenging Association. Shock. 2017 Mar;47(3):276–87. pmid:27787406
- 58. Aldea Mansilla C, Martínez-Alarcón J, Gracia Ahufinger I, Guembe Ramírez M. Microbiological diagnosis of catheter-related infections. Enfermedades Infecc y Microbiol Clin (English ed). 2019 Dec;37(10):668–72. pmid:30220518
- 59. Duszynska W, Rosenthal VD, Szczesny A, Zajaczkowska K, Fulek M, Tomaszewski J. Device associated -health care associated infections monitoring, prevention and cost assessment at intensive care unit of University Hospital in Poland (2015–2017). BMC Infect Dis. 2020 Oct;20(1):761. pmid:33066740
- 60. Novosad SA, Fike L, Dudeck MA, Allen-Bridson K, Edwards JR, Edens C, et al. Pathogens causing central-line-associated bloodstream infections in acute-care hospitals-United States, 2011–2017. Infect Control Hosp Epidemiol. 2020 Mar;41(3):313–9. pmid:31915083