Figures
Abstract
Purpose
To investigate the psychometric performance and responsiveness of Catquest-9SF, a patient-reported questionnaire developed to evaluate visual function as related to daily tasks, in patients referred for cataract surgery in Ontario, Canada.
Methods
This is a pooled analysis on prospective data collected for previous projects. Subjects were recruited from three tertiary care centers in Peel region, Hamilton, and Toronto, Ontario, Canada. Catquest-9SF was administered pre-operative and post-operatively to patients with cataract. Psychometric properties, including category threshold order, infit/outfit, precision, unidimensionality, targeting, and differential item functioning were tested using Rasch analysis with Winsteps software (v.4.4.4) for Catquest-9SF. Responsiveness of questionnaire scores to cataract surgery was assessed.
Results
934 patients (mean age = 71.6, 492[52.7%] female) completed the pre- and post-operative Catquest-9SF questionnaire. Catquest-9SF had ordered response thresholds, adequate precision (person separation index = 2.01, person reliability = 0.80), and confirmed unidimensionality. The infit range was 0.75–1.29 and the outfit range was 0.74–1.51, with one item (‘satisfaction with vision’) misfitting (outfit value = 1.51). There was mistargeting of -1.07 in pre-operative scores and mistargeting of -2.43 in both pre- and post-operative scores, meaning that tasks were relatively easy for respondent ability. There was no adverse differential item functioning. There was a mean 1.47 logit improvement in Catquest-9SF scores after cataract surgery (p<0.001).
Citation: Kabanovski A, Shah B, D’Silva C, Ma J, Minotti SC, Qian J, et al. (2023) Multi-center validation of Catquest-9SF visual function questionnaire in Ontario, Canada. PLoS ONE 18(7): e0278863. https://doi.org/10.1371/journal.pone.0278863
Editor: Timo Eppig, Saarland University, GERMANY
Received: April 27, 2022; Accepted: November 25, 2022; Published: July 6, 2023
Copyright: © 2023 Kabanovski et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the paper and its Supporting Information files.
Funding: The authors received no specific funding for this work.
Competing interests: I have read the journal’s policy and the authors of this manuscript have the following competing interests: M.B.S: Consulting: Alcon, Allergan, Bausch and Lomb Health, Light Matter Interaction, Santen. Honorarium: Alcon, Allergan, Johnson & Johnson Vision, Thea-Labtician. Other authors do not have any conflicts of interest to disclose. The following authors have declared that no competing interests exist: AK, BS, CD, JM, SCM, JQ, WH, RR, VC, SE, IIA.
1 Introduction
The demand for cataract surgery is growing worldwide [1], creating a challenging task to accurately evaluate appropriateness for surgery and decide on waitlist prioritization. Traditionally, visual acuity was the main indicator of visual function. However, other factors, like brightness, contrast, and glare, also affect visual function and must be considered [2, 3]. Thus, there is a growing need for a tool to accurately evaluate patients’ self-reported visual function as related to daily life.
Several quality-of-life questionnaires were created to measure visual function, including Catquest, Activities of Daily Vision Scale, Visual Functioning-14, and others [4–7]. These questionnaires were developed using Classical Test Theory (CTT), which was recently shown to have significant limitations that can be overcome with a newer approach called Rasch analysis [8]. In CTT, values assigned to responses are added together, which may be inaccurate because steps along the continuum may be unequal [9]. In Rasch analysis, data are converted to a scale with equally sized steps, which allows addition of scores, more accurate comparisons, and use of parametric statistics [9, 10].
Catquest was developed in Sweden using CTT in 1997 [11]. In 2009, Rasch analysis was applied to Catquest creating a new 9-item version called Catquest-9SF [12]. As of 2020, Catquest-9SF has been culturally adapted and validated in at least 12 countries and 12 languages (Chinese, Danish, Dutch, French, German, Italian, Malay, Portuguese, Russian, Spanish, English, and Swedish) [12–28]. In all populations, Catquest-9SF proved to be a reliable instrument for measuring visual function and it is currently frequently used to assess the visual function and satisfaction of patients undergoing cataract surgery, particularly with multifocal or extended depth-of-focus lenses [29–31]. Researchers who designed the Catquest-9SF in Sweden recently demonstrated that the questionnaire retained its long-term stable psychometric properties (over a period of 11 years) [31]. It is short and was rated as a higher-quality tool compared to others due to its psychometric performance and high responsiveness to cataract surgery [10, 32].
Despite the need for a visual function questionnaire, there are barriers for implementation of such a tool in routine care. For example, there was heterogeneity in the psychometric results across validation studies, suggesting that questionnaire performance can be population specific. Thus, questionnaires must be validated in new populations before use. Our group previously performed a Rasch validation analysis for Catquest-9SF in one center in Peel Region, Ontario, with pre-operative scores only [17]. This was the first validation study in Canada, and the results demonstrated excellent performance. In the following study we assess whether Catquest-9SF is valid in patients with cataract across three centers in different regions in Ontario, using pre- and post-operative responses. We also assess responsiveness to clinical improvement after cataract surgery and examine the performance of shorter versions.
2 Methods
2.1 Questionnaire
Catquest-9SF contains 9 items [12], with 2 global assessment items(Ca,Cb) and 7 activity-specific items(C1-C7). Each item has four response options, with a raw score of 1 representing better visual function and 4 representing worse visual function. ‘Cannot decide’ is an option for all items, which was treated as missing data. The English translation of Catquest-9SF was used (S1 Fig).
2.2 Participants
A pooled analysis was performed on prospective data collected for previous projects at three sites in Ontario, Canada: Kensington Eye Institute (Toronto), Trillium Health Partners (Mississauga), and St. Joseph’s Healthcare Center (Hamilton). Catquest-9SF was administered pre- and post-operatively to patients. Before combining the data from different sites, a sensitivity analysis was performed to ensure the groups were similar in demographics (S1 Table). This study was approved by the Trillium Health Partners Research and Ethics Board (#984), Hamilton Research Ethics Board, and University of Toronto Research Ethics Board (#27054). Written consent was obtained from participants.
2.3 Rasch analysis
In Rasch analysis, a single linear scale, measured in log of the odds (logit) units, is created to measure the person’s ability to perform a task (visual function) and the level of difficulty of the task (item difficulty) [33]. A person with a better visual function, or a difficult item, falls on the negative side of the scale. Rasch analysis was performed for two datasets using Winsteps software (v.4.4.4). The first analysis (Analysis A) included only pre-operative scores. All respondents with available pre-operative visual acuity for both eyes and no more than two missing responses on the pre-operative Catquest-9SF were included. The second analysis (Analysis B) was performed on stacked pre-operative and post-operative scores. Respondents from Analysis A with no more than two missing responses on the post-operative Catquest-9SF were included. A detailed explanation of the psychometric properties assessed was previously published [17]. Briefly, category threshold order shows whether response options are ordered appropriately, infit and outfit indicate if the data match the Rasch model, and unidimensionality determines whether the questionnaire only measures one trait. Precision is determined by the person separation index (number of levels of ability that can be distinguished in respondents) and person reliability (a measure of internal consistency). Targeting assesses whether person ability matches item difficulties. Differential item functioning assesses whether respondents from various subgroups with similar abilities respond differently to an item [17].
2.4 Responsiveness
Raw Catquest-9SF scores were converted to logit scores based on results of Analysis B (S2 Table). A higher raw score was translated to a more positive logit score. For each subject, each raw score was converted to logit for the item. Logit scores for individual items were summed and divided by 9 (total number of items), to determine the subject’s logit score on the questionnaire. Improvement in logit scores after surgery was assessed with a paired t-test. Mean and standard deviations (SD) are reported. p-values<0.05 were statistically significant.
2.5 Validation of Catquest-9SF subsets
Catquest-9SF is a relatively short questionnaire compared to other available tools. However, Sparrow et al. previously suggested that an even shorter questionnaire may be preferred [14]. In our previous validation in Ontario, we used Rasch analysis to explore the psychometric performance of 8-item, 7-item, and 5-item subsets of Catquest-9SF [17]. In all sub-analyses, reducing the number of items lowered precision. The best 8-item subset included items Ca,Cb,C1,C2,C3,C5,C6, and C7, and the best 5-item subset included items Cb,C1,C2,C3, and C7. The 8-item subset had excellent precision, distinguishing between low, medium, and high visual function, while the 5-item subset had adequate precision to distinguish only between low or high ability. In this study, Rasch analysis was performed on these two subsets.
Based on the above results, we would expect that shortening the questionnaire to less than five items would further reduce precision. However, an ultrashort questionnaire may provide unique benefits which may outweigh the limitation of reduced precision. For example, the Patient Health Questionnaire 2 (PHQ-2) is a two-item subset of PHQ-9, which is used for diagnosis of depression [34]. PHQ-2 has 95% sensitivity in diagnosis of depression and is commonly used in screening [35]. Thus, it is worthwhile to investigate the performance of an ultrashort subset of Catquest-9SF as it may help when administration of a full questionnaire is impractical.
We proposed a new 3-item subset of Catquest-9SF. Based on the best 5-item subset (Cb,C1,C2,C3,C7) from our previous analysis, the easiest item (C2-‘recognize faces’) and the most difficult item (Cb-‘satisfaction with vision’) were included so that respondents with extremes of visual function can be identified. For the third item, one of the remaining items–C1-‘read text in newspaper’, C3-‘see prices when shopping’, or C7-‘carry out a hobby’–could be chosen. In C7, ‘hobby’ could be interpreted differently based on respondents’ interests, as was the case in another study using this word to describe various activities [36]. In C1, not all respondents read newspapers, and the activity is not known to affect activities of daily living (ADL). C3 is related to grocery shopping, which is an instrumental ADL [37]. A limitation in the ability to shop is known to affect independence and quality of life [37]. Furthermore, vision impairment is associated with disability based on self-reported difficulty with ADLs, highlighting the potential importance of this item [38]. Thus, item C3 was chosen and Rasch analysis was re-run for the 3-item subset (Cb,C2,C3).
3 Results
3.1 Participants
Data was collected for 1786 patients. 1523 patients were included in Analysis A, with median age 72.0 (mean = 71.5,SD = 8.72), 518 (51.7%) female, and 696 (51.7%) completed high school or less. 934 subjects were included in Analysis B, with median age 72.0 (mean = 71.6,SD = 8.80), 492 (52.7%) female, and 387 (48.9%) completed high school or less (Table 1).
3.2 Rasch analysis
In both Analysis A and B, Catquest-9SF demonstrated ordered category thresholds, acceptable fit statistics with one item misfitting, adequate precision, and unidimensionality. There was mistargeting, indicating that the items were relatively easy for respondent ability. The results for all criteria are outlined below.
3.2.1 Threshold order.
Category thresholds were ordered for all items (Analysis A: S2 Fig; Analysis B: S3 Fig).
3.2.2 Item calibration and fit.
Analysis A: Infit range was 0.85–1.38 and outfit range was 0.76–1.54 (Table 2). Item Cb-‘satisfaction with vision’ had an outfit value of 1.54. Analysis B: Infit range was 0.75–1.29 and outfit range was 0.74–1.51 (Table 2). Item Cb had an outfit value of 1.51. The acceptable range is 0.50–1.50, with values 1.5–2.0 being unproductive for measurement but not degrading.
3.2.3 Unidimensionality.
According to the principal component analysis of the residuals, the observed explained variance was close to the value expected if the data fit the Rasch model perfectly (Analysis A: observed = 61.3%,expected = 61.7%; Analysis B: observed = 60.4%,expected = 60.6%). The unexplained variance explained by the first contrast was 1.72 eigenvalue units in Analysis A and 1.75 in analysis B, which is less than 2.0 and therefore meets criteria for unidimensionality.
3.2.4 Precision.
Person separation index and person reliability were 2.49 and 0.86, respectively, in Analysis A and 2.01 and 0.80 in Analysis B, meaning that the questionnaire can discriminate respondents who have low, medium, and high abilities (minimum acceptable values are 2.00 and 0.80, respectively) [34]. Cronbach’s alpha was 0.90 in Analysis A and 0.92 in Analysis B, indicating excellent internal consistency (0.70 to <0.80 is acceptable, 0.80 to <0.90 is good, and 0.90 or higher is excellent) [14, 16].
3.2.5 Targeting.
The mean person location was -1.07 in Analysis A and -2.43 in Analysis B. Optimal value is between -1.00 and 1.00. Negative mistargeting means that respondents reported minimal difficulties with the questionnaire tasks.
3.2.6 Differential Item Functioning (DIF).
Analysis A: There was no significant DIF for Catquest-9SF with respect to age. Small but statistically significant DIF (defined as DIF contrast between 0 and 0.5 and Rasch-Welch p<0.05) occurred as a function of gender for item Ca-‘difficulties in daily life’(DIF contrast = 0.27,p = 0.011,rated more difficult by men) and as a function of education level for C1-‘read newspaper text’(DIF contrast = 0.23,p = 0.0092,rated more difficult by those with education of high-school or less).
Analysis B: There was statistically significant DIF for some items with respect to age, gender, and pre-/post-operative status (Table 3). A detailed assessment of the pre-/post-operative DIF was performed using racked data, which focuses on the change in item difficulty, rather than person ability, from before surgery to after surgery (S3 Table). There was no DIF with respect to education level.
Age groups were categorized as <65 years old and 65+ years old. DIF contrast <0.5 logits is considered small or absent, 0.50 to 1.0 logits is minimal, while >1.0 logits is notable.
3.2.7 Person-item map.
In both Analysis A and B, the easiest question was C2-‘recognize faces’, meaning that only respondents with very low visual function reported difficulty. The most difficult question was Cb-‘satisfaction with vision’, indicating that even respondents with high visual function reporting dissatisfaction. The person-item maps (Fig 1) show that C5-‘do needlework/handicraft’ and C7-‘carry out a hobby’ are on the same line. Items C3-‘see prices when shopping’,Ca-‘difficulties in daily life’,C1-‘read newspaper text’ and C6-‘read text on television’ are also at a similar position on the scale.
Person-item map for Catquest-9SF including A) pre-operative scores only and B) combined pre- and post-operative scores. The left side of the vertical line shows respondent data while the right side shows positioning of items. Respondents with higher visual function and items with higher difficulty are positioned at the bottom of the line. Each ‘#’ represents 2 respondents and each ‘.’ represents 1 respondent. M: mean, S:1 standard deviation, T: 2 standard deviations. The scale is in logits.
3.3 Responsiveness
The raw scores were converted to logit scores and the mean logit score was used to determine questionnaire score pre- and post-operatively (S2 Table, S4 Fig). In most subjects, visual function based on total Catquest-9SF scores improved after cataract surgery, as expected (Fig 2). Of 934 subjects, 801 (85.8%) reported improvement, 8 (0.9%) reported no change, and 125 (13.4%) had decreased visual function. The mean pre-operative score was -1.70±1.3 logits, and the mean post-operative score was -3.17±1.1 logits. The improvement of 1.47 logits was statistically significant (p<0.001,paired 2-tailed t-test). All items became easier after surgery. Item Cb-‘satisfaction with vision’ had the largest change in item calibration and C5-‘do needlework/handicraft’ had the smallest.
Subjects who had improvement in visual function after cataract surgery fall under the diagonal line (a higher Catquest-9SF score represents poor visual function).
An extended analysis was performed to further investigate why some subjects did not have improvement of Catquest-9SF scores after surgery (Table 4). Of 934 subjects, 809 had improvement or no change in Catquest-9SF scores after surgery compared to before surgery, and 125 subjects had worsening scores.
VA: Visual acuity. Those who had no change in score were grouped with those who had improvement in scores.
There was a mild statistically significant correlation between change in vision in the better eye and change in Catquest-9SF scores (pre- to post-operatively; Pearson correlation = 0.19, p = 0.004, two-tailed significance). There was no correlation between change in vision in the worse eye and change in Catquest-9SF scores (p = 0.601, two-tailed significance).
Mann Whitney U test did not demonstrate a statistically significant difference in the change in Catquest-9SF scores (pre to post-op) as related to age, gender, and education level.
3.4 Validation of Catquest-9SF subsets
Assessment of questionnaire subsets using only pre-operative scores demonstrated acceptable psychometric properties for all shortened versions (Table 5). The 8-item subset had no misfitting items, adequate precision to distinguish between low, medium, and high visual function with person separation index (PSI) = 2.41, person reliability (PR) = 0.85, and acceptable targeting (-0.97). The 5-item and 3-item combinations had one misfitting item (Cb-‘satisfaction with vision’) and adequate precision to distinguish between low and high visual function (PSI = 1.94,PR = 0.79 for 5-item; PSI = 1.53,PR = 0.70 for 3-item; acceptable values are PSI>1.5 and PR>0.7, for this level of precision). There was mild mistargeting for both versions (-1.06 for 5-item, -1.23 for 3-item), indicating that the tasks described in the items were relatively easy for respondents to perform. There was no differential item functioning of magnitude above 0.50.
Separate analyses presented for pre-operative scores only and combined pre- and post-operative scores (stacked data). *Presented as item: DIF contrast (p-value). PSI: person separation index, PR: person reliability.
Assessment of questionnaire subsets using both pre-operative and post-operative scores demonstrated acceptable psychometric properties for the 8-item and 5-item versions (Table 5). Item Cb misfit in both subsets with outfit values 1.53 (8-item) and 1.64 (5-item). The 8-item combination had adequate precision to discriminate between three levels of visual function (PSI = 2.01,PR = 0.80, acceptable values are PSI>2.0,PR>0.8), and the 5-item version had adequate precision to discriminate between two groups (PSI = 1.68,PR = 0.74, acceptable values are PSI>1.5,PR>0.7). The 3-item questionnaire had acceptable fit statistics with no misfitting items. Precision was inadequate, meaning that the questionnaire could not distinguish between at least two levels of visual function (PSI = 1.38,PR = 0.66). There was significant mistargeting in all three versions (-2.40,-2.45,-2.69 for the 8-item, 5-item, 3-item versions, respectively).
4 Discussion
Catquest-9SF demonstrated excellent Rasch-based psychometric properties in 12 world populations [12–16]. The questionnaire was previously validated in Peel Region, Ontario, Canada, using pre-operative scores only [17]. The current study assessed its performance in a large sample of pre- and post-operative cataract patients across 3 centers in Ontario. We show that Catquest-9SF has valid psychometric properties and is a suitable visual function questionnaire for use in Ontario. Implementation into routine care may aid in assessing appropriateness for cataract surgery and prioritization on waitlists. The questionnaire is also responsive to changes in visual function after cataract surgery, making it a potentially useful tool for assessment of surgical outcomes. Those who had improvement in Catquest-9SF scores from pre- to post-op had worse pre-operative visual acuity. Thus, subjects with worse visual acuity pre-operatively likely report greater improvement in their ability to perform daily activities when the vision improves, which is expected. There were no other variables that contributed to why a subject reported improvement or worsening of Catquest-9SF scores after surgery.
Catquest-9SF fulfilled all Rasch criteria. Precision was adequate to separate respondents based on low, medium, and high visual function. There was some mistargeting, meaning that the items were relatively easy for respondents. Mistargeting was greater when post-operative scores were included, which is expected because cataract surgery usually improves visual function.
Our Rasch analysis of Catquest-9SF showed similar results to the previous preoperative validation study in Ontario [17, S4 Table] and studies in other countries [39]. There is notable improvement with targeting in the current study (-1.07 pre-operatively), compared to the previous Ontario study (-1.43) [17]. Mistargeting was common in other studies (range -1.36 to -1.61) [16, 19, 21, 25, 39]. In all previous research, including the Ontario study, category thresholds were ordered, unidimensionality was confirmed, precision was adequate, and the person-item maps were similar.
In the previous Ontario study, all items demonstrated acceptable fit statistics. In this study, one item (Cb–‘satisfaction with vision’) had an outfit of 1.54 (maximum acceptable value = 1.50). In this case, high outfit may be because respondents with low visual function reported that they were satisfied with vision, or vice versa. In previous validation studies, misfitting items were removed from analysis. One study removed C5-‘do needlework/handicraft’ and another study removed C2-‘recognize faces’ and C4-‘walk on uneven ground’ [20, 24]. We did not remove the misfitting item because the outfit value was not degrading to the measurement. Furthermore, in a previous study where Catquest-9SF was shortened to 5 items, Cb was among the important questions to keep in the questionnaire [17].
There was no differential item functioning with respect to age, gender, or education level (DIF contrast>0.5). All items became easier after surgery, as expected. For some items, the improvements in scores were greater (Cb,C2,C6) and for others lower (C1,C3,C5) than expected based on the average improvement on all items. This shows that patients report different levels of improvement in visual function for different activities.
Shortened versions of the Catquest-9SF demonstrated promising results. The 8-item subset had excellent psychometric properties and performed better than the 9-item version in some areas. For example, pre-operatively, Catquest-9SF had one misfitting item and mild mistargeting, while the 8-item subset had excellent fit and targeting. In the analysis including pre- and post-operative scores, the 8-item and 9-item questionnaires performed similarly. Considering both analyses, the 8-item subset demonstrated better psychometric properties while also being shorter than Catquest-9SF.
The main limitation of the 5-item and 3-item versions is reduced precision compared to Catquest-9SF, and this is consistent with previous findings in Ontario [17]. The 5-item subset could not discriminate between three levels of ability like the 9-item version, but there was adequate precision to discriminate between two levels. This was the case in both the current study and the previous validation study in Ontario [17].
In analyzing only pre-operative scores, the 3-item subset performed similarly to Catquest-9SF except that it had adequate precision to discriminate between two, but not three, levels of visual function. Targeting was slightly reduced relative to Catquest-9SF. However, in the combined pre- and post-operative analysis, the 3-item version had unacceptable precision. Thus, the 3-item subset may be more suitable for analysis of only pre-operative visual function rather than combined pre-operative and post-operative data.
The main strengths of this study are the large sample size across three centers in different regions of Ontario and the availability of pre-operative and post-operative scores for assessment of responsiveness. One important limitation is that our pre- and post-operative scores come from the same subject. This violates an assumption in Rasch analysis which requires that all observations be independent [40]. One previous study changed the study design to prevent this violation [14], while all other studies stacked the pre-operative and post-operative scores into one dataset, which was our approach [12, 15, 19, 20, 22–25]. We report the results of the Rasch analysis on only pre-operative scores, where all observations are independent, to ensure that this did not inflate reliability and precision. Furthermore, due to our large sample size spanning several sites, there was missing data (Table 1). Also, since this is a pooled analysis, we do not have information on which eye (left or right) was operated on, so analysis was performed by categorizing visual acuity as ‘better’ or ‘worse’ eye.
In conclusion, Catquest-9SF demonstrated excellent psychometric properties and is a valid and reliable tool for measuring visual function before and after cataract surgery in Ontario. There is some mistargeting which indicates that the tasks are easy to perform, which is consistent with findings in other populations. Shortened variations of Catquest-9SF may be suitable for use, particularly pre-operatively. Future research should explore implementation of Catquest-9SF for clinical decision-making.
Supporting information
S2 Fig. Category probability curves for Catquest-9SF (including only pre-op scores).
Including all 9 items.
https://doi.org/10.1371/journal.pone.0278863.s002
(TIF)
S3 Fig. Category probability curves for Catquest-9SF (including pre and post-op scores).
Including all 9 items.
https://doi.org/10.1371/journal.pone.0278863.s003
(TIF)
S4 Fig. Distribution of pre-operative and post-operative Catquest-9SF logit scores.
N = 934.
https://doi.org/10.1371/journal.pone.0278863.s004
(TIF)
S1 Table. Sensitivity analysis of demographic factors between sites.
https://doi.org/10.1371/journal.pone.0278863.s005
(DOCX)
S2 Table. Conversion table between raw scores on Catquest-9SF to logit scores.
Based on combined analysis of pre- and post-operative scores in 934 subjects. Raw score legend: 1 = No difficulty, 2 = Some difficulty, 3 = Great difficulty, 4 = Very great difficulty.
https://doi.org/10.1371/journal.pone.0278863.s006
(DOCX)
S3 Table. Assessment of differential item functioning for pre vs. post-operative groups.
Data analyzed through racked approach. Total N = 934; 38 subjects were missing at least one item response for both pre- and post-operative Catquest-9SF; subjects with missing data were still accounted for according to the conversion table for logit scores. DIF: Differential item functioning. SE: Standard error.
https://doi.org/10.1371/journal.pone.0278863.s007
(DOCX)
S4 Table. Comparison of Rasch analysis results of current multi-center study in Ontario, Canada and previous single-center study in Ontario, Canada [17].
PSI: Person Separation Index, PR: Person Reliability.
https://doi.org/10.1371/journal.pone.0278863.s008
(DOCX)
References
- 1. Hatch WV, Campbell Ede L, Bell CM, El-Defrawy SR, Campbell RJ. Projecting the growth of cataract surgery during the next 25 years. Arch Ophthalmol. 2012 Nov;130(11):1479–81. pmid:23143457
- 2. Chaudhary V, Popovic M, Holmes J, Robinson T, Mak M, Mohaghegh P SM, et al. Predictors of functional vision changes after cataract surgery: the PROVISION study. Can J Ophthalmol. 2016 Aug;51(4):265–270. pmid:27521665
- 3. Massof RW, Rubin GS. Visual function assessment questionnaires. Surv Ophthalmol. 2001 May-Jun;45(6):531–48. pmid:11425359
- 4. Mangione CM, Lee PP, Gutierrez PR, Spritzer K, Berry S, Hays RD, et al. Development of the 25-item National Eye Institute Visual Function Questionnaire. Arch Ophthalmol. 2001 Jul;119(7):1050–8. pmid:11448327
- 5. Pesudovs K, Garamendi E, Keeves JP, Elliott DB. The Activities of Daily Vision Scale for cataract surgery outcomes: re-evaluating validity with Rasch analysis. Invest Ophthalmol Vis Sci. 2003 Jul;44(7):2892–9. pmid:12824228
- 6. Steinberg EP, Tielsch JM, Schein OD, Javitt JC, Sharkey P, Cassard SD, et al. The VF-14. An index of functional impairment in patients with cataract. Arch Ophthalmol. 1994 May;112(5):630–8. pmid:8185520
- 7. Burr JM, Kilonzo M, Vale L, Ryan M. Developing a preference-based Glaucoma Utility Index using a discrete choice experiment. Optom Vis Sci. 2007 Aug;84(8):797–808. pmid:17700343
- 8. Braithwaite T, Calvert M, Gray A, Pesudovs K, Denniston AK. The use of patient-reported outcome research in modern ophthalmology: impact on clinical trials and routine clinical practice. Patient Relat Outcome Meas. 2019 Jan 24;10:9–24. pmid:30774489
- 9. Prieto L, Alonso J, Lamarca R. Classical Test Theory versus Rasch analysis for quality of life questionnaire reduction. Health Qual Life Outcomes. 2003 Jul 28;1:27. pmid:12952544
- 10. Khadka J, McAlinden C, Pesudovs K. Quality assessment of ophthalmic questionnaires: review and recommendations. Optom Vis Sci. 2013 Aug;90(8):720–44. pmid:23873034
- 11. Lundström M, Roos P, Jensen S, Fregell G. Catquest questionnaire for use in cataract surgery care: description, validity, and reliability. J Cataract Refract Surg. 1997 Oct;23(8):1226–36. pmid:9368170
- 12. Lundström M, Pesudovs K. Catquest-9SF patient outcomes questionnaire: nine-item short-form Rasch-scaled revision of the Catquest questionnaire. J Cataract Refract Surg. 2009 Mar;35(3):504–13. pmid:19251145
- 13. Adnan TH, Mohamed Apandi M, Kamaruddin H, Salowi MA, Law KB, Haniff J, et al. Catquest-9SF questionnaire: validation of Malay and Chinese-language versions using Rasch analysis. Health Qual Life Outcomes. 2018 Jan 5;16(1):5. pmid:29304817
- 14. Sparrow JM, Grzeda MT, Frost NA, Johnston RL, Liu CSC, Edwards L, et al. Cataract surgery patient-reported outcome measures: a head-to-head comparison of the psychometric performance and patient acceptability of the Cat-PROM5 and Catquest-9SF self-report questionnaires. Eye (Lond). 2018 Apr;32(4):788–795. pmid:29386619
- 15. Visser MS, Dieleman M, Klijn S, Timman R, Lundström M, Busschbach JJ, et al. Validation, test-retest reliability and norm scores for the Dutch Catquest-9SF. Acta Ophthalmol. 2017 May;95(3):312–319. pmid:27775237
- 16. Xu Z, Wu S, Li W, Dou Y, Wu Q. The Chinese Catquest-9SF: validation and application in community screenings. BMC Ophthalmol. 2018 Mar 20;18(1):77. pmid:29554884
- 17. Schlenker MB, Minotti SC, Kabanovski A, Lim M, D’Silva C, Ma J, et al. Catquest-9SF questionnaire and eCAPS: Validation in a Canadian population. PLoS One. 2020 Sep 25;15(9):e0237788. pmid:32976522
- 18. Gothwal VK, Wright TA, Lamoureux EL, Lundström M, Pesudovs K. Catquest questionnaire: re-validation in an Australian cataract population. Clin Exp Ophthalmol. 2009 Nov;37(8):785–94. pmid:19878224
- 19. Harrer A, Gerstmeyer K, Hirnschall N, Pesudovs K, Lundström M, Findl O. Impact of bilateral cataract surgery on vision-related activity limitations. J Cataract Refract Surg. 2013 May;39(5):680–5. pmid:23535380
- 20. Khadka J, Huang J, Chen H, Chen C, Gao R, Bao F, et al. Assessment of Cataract Surgery Outcome Using the Modified Catquest Short-Form Instrument in China. PLoS One. 2016 Oct 13;11(10):e0164182. pmid:27736889
- 21. Lin X, Li M, Wang M, Zuo Y, Zhu S, Zheng Y, et al. Validation of Catquest-9SF questionnaire in a Chinese cataract population. PLoS One. 2014 Aug 1;9(8):e103860. pmid:25084020
- 22. Lundstrom M, Behndig A, Kugelberg M, Montan P, Stenevi U, Pesudovs K. The outcome of cataract surgery measured with the Catquest-9SF. Acta Ophthalmol. 2011 Dec;89(8):718–23. pmid:20039853
- 23. Lundström M, Llovet F, Llovet A, Martinez Del Pozo M, Mompean B, González JV, et al. Validation of the Spanish Catquest-9SF in patients with a monofocal or trifocal intraocular lens. J Cataract Refract Surg. 2016 Dec;42(12):1791–1796.
- 24. Nielsen E, Lundström M, Pesudovs K, Hjortdal J. Validation of Catquest-9SF in Danish: developing a revised form of the Catquest-9SF—the Danish Catquest-7SF. Acta Ophthalmol. 2019 Mar;97(2):173–177. pmid:30242976
- 25. Skiadaresi E, Ravalico G, Polizzi S, Lundström M, González-Andrades M, McAlinden C. The Italian Catquest-9SF cataract questionnaire: translation, validation and application. Eye Vis (Lond). 2016 Apr 28;3:12. pmid:27127797
- 26. Katz G, Rouquette A, Lignereux F, Mourgues T, Weber M, Lundström M. Validity of the French version of Catquest-9SF and use of an electronic notepad for entering patient-reported outcome measures. Eye Vis (Lond). 2021 Apr 1;8(1):11. pmid:33789766
- 27.
Chukhraev AM, Omelyanovskiy VV, Shchurov DG, Musina NZ, Savin EA, Gostishchev RV, et al. Validity and reliability assessment of the Russian version of the CATQUEST-9SF questionnaire. Available from: https://conference.ichom.org/wp-content/uploads/2021/10/1821.pdf
- 28. Antunes HM, Magalhães LC, Vasconcelos GC, Trindade BLC, Gonzaga ACM, Antunes RPG. Catquest-9SF questionnaire: validation of the Portuguese version using the Rasch analysis. Arq Bras Oftalmol. 2022 Feb 14:S0004–27492022005003212.
- 29. Spekreijse LS, Bauer NJC, van den Biggelaar FJHM, et al. Predictive accuracy of an intraoperative aberrometry device for a new monofocal intraocular lens. J Cataract Refract Surg. 2022;48(5):542–548. pmid:34433779
- 30. Galvis V, Escaf LC, Escaf LJ, et al. Visual and satisfaction results with implantation of the trifocal Panoptix® intraocular lens in cataract surgery. J Optom. 2022;15(3):219–227.
- 31. Lundström M, Kugelberg M, Montan P, et al. Catquest-9SF functioning over a decade—a study from the Swedish National Cataract Register. Eye Vis (Lond). 2020;7(1):56. Published 2020 Dec 1 pmid:33292703
- 32. McAlinden C, Gothwal VK, Khadka J, Wright TA, Lamoureux EL, Pesudovs K. A head-to-head comparison of 16 cataract surgery outcome questionnaires. Ophthalmology. 2011 Dec;118(12):2374–81. pmid:21945088
- 33.
Linacre JM. User’s Guide to Winsteps: Rasch-Model Computer Program. Chicago: Mesa Press; 2002.
- 34. Kroenke K, Spitzer RL, Williams JB. The Patient Health Questionnaire-2: validity of a two-item depression screener. Med Care. 2003 Nov;41(11):1284–92. pmid:14583691
- 35. Whooley MA, Avins AL, Miranda J, Browner WS. Case-finding instruments for depression. Two questions are as good as many. J Gen Intern Med. 1997 Jul;12(7):439–45. pmid:9229283
- 36. Brown JC, Goldstein JE, Chan TL, Massof R, Ramulu P; Low Vision Research Network Study Group. Characterizing functional complaints in patients seeking outpatient low-vision services in the United States. Ophthalmology. 2014 Aug;121(8):1655–62.e1.
- 37.
Edemekong PF, Bomgaars DL, Sukumaran S, Levy SB. Activities of Daily Living. [Updated 2021 Jul 26]. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2021 Jan-. Available from: https://www.ncbi.nlm.nih.gov/books/NBK470404
- 38. Whitson HE, Malhotra R, Chan A, Matchar DB, Østbye T. Comorbid visual and cognitive impairment: relationship with disability status and self-rated health among older Singaporeans. Asia Pac J Public Health. 2014 May;26(3):310–9. pmid:22535554
- 39. Kabanovski A, Hatch W, Chaudhary V, El-Defrawy S, Reid R, Ahmed IIK, et al. Validation and application of Catquest-9SF in various populations: A systematic review. Surv Ophthalmol. 2020 May-Jun;65(3):348–360. pmid:31862206
- 40. Baghaei P. Local Dependency and Rasch Measures. Rasch Measurement Transactions; 2008.