Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Age-related decline in function of ON and OFF visual pathways

  • Amithavikram R. Hathibelagal ,

    Roles Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Resources, Supervision, Validation, Visualization, Writing – original draft, Writing – review & editing

    amithavikram@lvpei.org

    Affiliations Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India, Prof. Brien Holden Eye Research Center, L V Prasad Eye Institute, Hyderabad, India

  • Vishal Prajapati,

    Roles Data curation, Formal analysis, Investigation, Methodology

    Affiliations Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India, Prof. Brien Holden Eye Research Center, L V Prasad Eye Institute, Hyderabad, India

  • Indrani Jayagopi,

    Roles Conceptualization, Data curation, Investigation, Methodology

    Affiliations Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India, Prof. Brien Holden Eye Research Center, L V Prasad Eye Institute, Hyderabad, India

  • Subhadra Jalali,

    Roles Validation, Visualization, Writing – review & editing

    Affiliations Srimati Kanuri Santhamma Centre for vitreoretinal diseases, L V Prasad Eye Institute, Hyderabad, India, Jasti V Ramanamma Children’s Eye Care Centre, L V Prasad Eye Institute, Hyderabad, India

  • Shonraj Ballae Ganeshrao

    Roles Conceptualization, Formal analysis, Methodology, Validation, Visualization, Writing – original draft, Writing – review & editing

    Affiliation Department of Optometry, Manipal College of Health Professions, Manipal Academy of Higher Education (MAHE), Manipal, Karnataka, India

Abstract

Purpose

A simple psychophysical paradigm is available as a digital application in iOS devices such as iPad to measure the function of ON and OFF visual pathways. However, an age-matched normative database is not readily available. The purpose of the study is to evaluate the response of ON and OFF visual pathways as a function of age.

Methods

158 normal healthy adults (84 males and 74 females) whose age ranged 18–80 years participated in the study. None of them had any ocular disease (except cataract of grade II or less) and visual acuity of ≤ 20/25. Monocular testing (only one eye) was performed on the ‘EyeSpeed’ application on an iPad at 40cm distance. The targets ranged between 1 to 3 light or dark squares presented randomly in a noise background and participants responded by indicating the number of squares by touching the screen as fast as possible. The main outcome variables are reaction time, accuracy and performance index (1 / speed * accuracy).

Results

The median reaction time was shorter (Median (IQR): 1.53s (0.49) [dark] Vs 1.76s (0.58) [light], p < 0.001) and accuracy was higher (97.21% (3.30) [dark] Vs 95.15% (5.10) [light], p < 0.001) for dark targets than the light targets. Performance index and reaction time for both target types significantly correlated with age (ρ = -0.41 to -0.43; p < 0.001).

Conclusions

This normative database will be useful to quantify disease-specific defects. More importantly, the ON pathway function can potentially serve as a surrogate for rod photoreceptor function.

Introduction

The luminance information from the eye to the brain is carried out by two pathways namely ON and OFF pathways [1], which start in the inner retina at the level of bipolar cells [2]. The ON pathway is responsible for the transmission of signals at/during light stimulation, whereas the OFF pathway is responsible for the transmission of signals after the light offset [1]. The OFF pathway is better represented than the ON pathway in visual cortex [35] which probably results in more accurate and faster detection of dark targets compared to light targets [68]. Beyond animal studies [35], this ON-OFF asymmetry has been demonstrated in humans using simple psychophysical paradigms [68]. More importantly, ON/OFF pathway-specific defects have been noted in congenital stationary night blindness [9], melanoma-associated retinopathy [9], amblyopia [10] and glaucoma [8]. However, to use ON-OFF asymmetries as a metric to identify disease-specific defects, one must have an age-matched normative database to distinguish between age-related decline compared to disease-specific defects.

Previously, the effect of age on the function of ON and OFF pathways has been studied in a small subset of individuals (n = 21) between 49–74 years [8]. However, such a small sample is not large enough to capture the age-related changes due to the following reasons. 1. The age at which visual function begins to decline cannot be captured. 2. The rate of change could be different in different phases of ageing. Besides, the test used previously was lab-based and the testing distance and size of the stimuli are different from the setup used in this study. A similar paradigm is now available for testing in a simple portable device as an application. The advantage of having a rapid, sensitive test that is portable is an attractive option in a clinical population relative to lab-based setups that can measure photoreceptor-specific thresholds [1113]. In this study, we aimed to determine the age-related changes in the detection of light and dark targets using an iPad-based freely available application called “EyeSpeed”.

Methods

This is a prospective cross-sectional study. The study protocol has been approved by the Institutional Review Board (IRB) of the L V Prasad Eye Institute, Hyderabad (IRB Application number: LEC 09-18-139). The inclusion criteria for the participants were as follows: 1. Age ≥ 18 years 2. No history of ocular/systemic disease. 3. Visual acuity at least 20/25 in the tested eye with refractive correction in place. 4. Cataract grade less than LOCS grade II or lower [14]. 5. No history of ocular surgery except pterygium and cataract. All the potential participants were briefed about the test and only if they agreed to participate, then they signed the consent form before participating in the study. The participant cohort included the patient population that visited the hospital campus, also the staff and student cohort from the institute.

Procedure

The participants wore their near correction if they were ≥ 40 years. The eye which has a better acuity was considered for testing. In case of equal acuity across the two eyes, the dominant eye determined by a simple test. The test involved the subject to extend their arms to create a triangular opening and fixate on an object with both eyes open and then close each eye alternatively to view the distant object. The eye through which, there was no change in view relative to binocular view was considered as dominant eye. The participant’s dominant eye was tested, while the other eye was occluded with a dark patch. Monocular testing was conducted so that it can be compared easily against the monocular measurements that will be made in upcoming studies in patients with retinal diseases, where disease severity may vary across the two eyes. The room illumination was standard room illumination of ~300 lux. The app called “EyeSpeed” was developed by a research group in USA [8] and is available on the iOS app store for free. The application was developed as a tool for easy testing the function of the ON and OFF visual pathways.

The test was carried out on an iPad (iPad 4th Generation; Model: MD525X/A, USA). The resolution of the device was 2048X1536 pixels. The participants held the tablet with the support of a table. The tablet was held such that there were no major reflections while viewing the screen during the test. The participant’s task was to correctly identify the number of targets against the noise background as fast as possible by tapping on the corresponding button on the touch-sensitive screen (see Fig 1). The participant was initially habituated to a ‘demo’ test for 20 trials before starting the test to avoid any learning effects. The noise squares width was 10 pixels, while the size of the target was 70 pixels. The tablet’s viewing area subtended 27.80° X 20.82° at a test distance of 40cm. The panel of noise background subtended ~18° at the distance of 40cm, while the target (dark/light) embedded in the noise background subtended ~2° at the same distance. The ratio of dark area to total area was 50% and the total number of trials was 200. A photometer (Konica Minolta LS-110, Japan) was used to measure the luminance of the light and dark targets. The mean luminance of the light patch was 128 ± 0.75 Cd/m2, while the luminance of the dark patch was 0.19 Cd/m2. The mean luminance of the noise background was 63.28 ± 6.16 Cd/m2. During the test, the participants viewed either a dark or a light target and the number of targets ranged from 1 to 3 (see Fig 1). In each presentation, the number of targets and type of targets (dark/light) also varied randomly. This type of stimulus has been used previously to elicit the ON and OFF responses in humans [6,8]. More specifically, light targets stimulate the ON pathway, while dark targets stimulate the OFF pathway. There was no fixed duration of the targets, however, they disappeared after the response was obtained from the participant. The average testing time was approximately 4–5 minutes. The key outcome variables obtained from the test was accuracy (%) and reaction time (s).

thumbnail
Fig 1. The display screen of the “EyeSpeed” app during the test.

The top panels show dark targets in a noise background and the bottom panels show the light targets. The option to choose the correct answer is shown in grey boxes. The number choices are presented in ascending order. Grey option boxes were also present for the top panels as well during the test, which has been removed in this representation for compact viewing.

https://doi.org/10.1371/journal.pone.0261489.g001

Data analysis

The data were not normally distributed as tested by the Kolmogorov-Smirnov test (p > 0.05). Wilcoxon Signed-Rank test is used to compare the parameters between light and dark targets. The p-value of < 0.05 was considered statistically significant. The performance index was computed as the product of speed (1/ reaction time [s]) and accuracy. Linear regression was performed to assess the relationship between age and parameters. The data was divided into 2 age groups namely ≤ 49 years and > 49 years to allow comparison with the previous study [8]. The Grubbs’ test was used to identify the outliers (Graph Pad Prism; https://www.graphpad.com/quickcalcs/Grubbs1.cfm).

Results

The mean [SD] age of the participants was 43.42 [14.5] years. The repeatability was assessed in a small subgroup of subjects (n = 10). The test was repeated within 1 week from the first visit. The coefficient of variation between visits for all the parameters in both the test conditions was within 20% of the mean. A total of 170 subjects were approached to participate in the study. Ten subjects (all above 40 years of age) were excluded as there were unable to perform the ‘demo’ test successfully. The excluded subjects had reaction time longer than 4 seconds, largely owing to the lack of familirisation to use of digital device and/or discontinued test after the first 50 trials due to fatigue.Two outliers were detected by Grubb’s test (P-value set to 0.05) and were excluded from the analysis. Therefore, data from 158 subjects (84 males and 74 females) were analyzed. The age distribution of subjects is provided in Fig 2. The mean (SD) refractive error of the cohort was -0.36 D (1.29). There were 17 pseudophakes in the cohort (mean (SD) age = 60.29(11.42) years).

thumbnail
Fig 2. Histogram showing the age distribution of individuals who participated in the study.

The numbers inside the bars represent the number of individuals in each decade, with the only exception being the last bar which shows individuals greater than 60 years of age.

https://doi.org/10.1371/journal.pone.0261489.g002

The reaction times were shorter (Median (IQR): 1.54s (0.50) [dark] Vs 1.77s (0.63) [light], Wilcoxon Signed Rank test, p < 0.001) and accuracy was higher (97.16% (3.35) [dark] Vs 95.15% (5.32) [light], p < 0.001) for detection of dark targets compared to light targets. Similarly, performance index was also significantly higher for dark targets (63.04%*s-1(20.69)) compared to light targets [(54.3%*s-1 (18.27)); p < 0.001]; see Fig 3.

thumbnail
Fig 3.

Box plots showing the accuracy (left panel), reaction time (middle panel) and performance index (right most panel) of all the subjects for dark and light targets respectively. The central solid horizontal line in each box represents the median and the solid black circles represent the outliers.

https://doi.org/10.1371/journal.pone.0261489.g003

There was no significant difference in accuracy between the two groups age ≤ 49 years and age > 49 years for dark targets. However, there was significant difference in accuracy for light targets (Table 1). However, there were significant differences in reaction time and performance index between the two groups,. All the parameters showed significant correlation with age except accuracy for dark targets (Spearman correlation, ρ = -0.06; p = 0.44) across the entire age range (see Fig 4). More specifically, the reaction time and performance index measures (for light and dark targets) showed significant negative correlation (ρ = -0.41 to -0.43; p < 0.001) with age, whereas accuracy (for light targets) showed weak negative correlation with age (ρ = -0.18; p = 0.02; see Fig 4). However, in each of the subgroups (≤ 49 years and age > 49 years), the parameters showed no significant correlation with age. None of the differences in parameters between dark and light targets (e.g., reaction time of dark targets–reaction time of light targets) and age showed any significant correlation. All the parameters were independent of refractive error (p > 0.05). None of the parameters in the pseudophakic group was significantly different from the age-matched cohort. Besides, there were no gender-specific differences in any of the parameters.

thumbnail
Fig 4. Left panels show outcome variables (accuracy, reaction time and performance index) for light targets as a function of age.

A similar representation shows the data for the right panels. The blue solid line in each of the panels represents the slope of the linear regression and the grey region represents the standard error of the fit.

https://doi.org/10.1371/journal.pone.0261489.g004

thumbnail
Table 1. Summary (median [IQR]) of the outcome variables between the two groups.

https://doi.org/10.1371/journal.pone.0261489.t001

Discussion

The main findings from the study are that visual performance in the detection of light and dark targets is dependent on age. Accuracy is independent of age, while the reaction time is relatively constant up to 40 years of age. Beyond this age, there is an increase in reaction time with the increase in age. The higher performance (i.e., shorter reaction times and higher accuracy) for dark targets relative to light targets is consistent with the previous literature [8,15]. This is an expected finding because the detection of dark and light targets is inferred to be via the OFF pathway and ON pathway respectively. The OFF pathway has a higher contrast gain than the ON pathway as shown in visually evoked potential (VEP) recordings in humans [16]. Besides, in animal models such as cats, it has been identified that OFF neurons have a larger representation in the visual cortex [3] and stronger connections in the thalamus relative to the ON neurons [4]. Also, the OFF pathway consists of almost twice the number of cortical neurons compared to the ON pathway [5]. Recently, the ‘neuronal blur’ hypothesis has been proposed to explain why it is harder to detect light targets than dark targets using a centre-surround model [17]. It states that the enlargement of the image due to ON response luminance saturation [7] causes the image to fall in the surround region, thus enhancing the suppression [17]. The ON/OFF asymmetries are also noticed at the retinal level [6,1821].

This is the first study that has looked at visual performance in the detection of light targets and dark targets over a wide age range of subjects from 18 years to 80 years. There was a significant correlation of reaction time with age across the entire age range. However, > 49 years of age, the reaction time for both targets (dark and light) were not correlated with age. Both these findings are consistent with Zhao et al (2014) [8]. Across all ages and in the subgroups (≤ 49 years and > 49 years), we have found that accuracy for both light and dark targets are independent of age, which is similar to the previous study [8].

Dark targets on light background stimulate the OFF pathway whereas, the light targets on dark background stimulate the ON visual pathway [17]. Westheimer et al (2003) had measured acuity on the normal polarity and reverse polarity charts on healthy normal subjects as a function of age [22], which is essentially a test of ON and OFF visual pathways. Acuities measured on both the charts showed a negative correlation with age. They showed that the rate of change in acuity measured using normal polarity charts (OFF pathway) is steeper than the acuities measured on the reverse contrast chart [22]. However, the rate of deterioration in visual performance for dark targets (OFF pathways) was similar to the light targets (slopes in Fig 4E and 4F) in this study. The discrepancies could be attributed to the differences in tasks (detection task [this study] Vs recognition task [Westheimer, 2003] measured between the studies. Besides, it is well known that reaction time in search-based tasks, increases with ageing [23]. The role of eye-hand coordination in increased reaction time with age cannot be discounted [24]. However, it could also be attributed to neuronal loss in the visual cortex [25]. There is currently no evidence to suggest that ageing affects one pathway more than the other in humans. None of our patients had any motor or neurological problems that could influence eye-hand coordination.

The differences between reaction time for light and dark targets showed no correlation with age, which is contrary to the previous report. Similarly, asymmetry in reaction times between ON and OFF targets (~200 ms) was also not very pronounced compared to Zhao et al [8] (~500–600 ms). The average time taken for identifying the dark targets is greater than the dark targets reaction time found in Zhao et al [8]. However, the magnitude of difference in accuracy between light and dark targets was smaller (~ 2–3 units) compared to the previous study reported by Zhao et al [8] which was ~8%. The major difference between this study and the lab-based study is that they had performed on a desktop monitor, while this was on an iPad. Therefore, we replicated the test containing 1–3 dark or light targets in a randomized manner using Psychopy program [26] and the participant was asked to press the keyboard buttons to respond. The results from this small sub-sample (n = 10) were similar to the larger database. The asymmetry in reaction time and accuracy was still smaller between the light and the dark targets. Although we tried to replicate the setup done by Zhao et al [8], there could be some methodological differences that could have accounted for the discrepancies. It is known that at higher luminances, the asymmetry in reaction times and accuracy between light and dark targets reduces [17]. That could also be attributed to the different results.

The normative database forms a useful test to differentiate age-related losses from disease-specific losses. The pathway-specific losses are noticed in glaucoma [8], melanoma-associated retinopathy [9], congenital stationary night blindness and also expected in rod-dominated diseases such as retinitis pigmentosa, rod dystrophy and rod monochromatism. The rationale for expected loss in rod-dominated diseases is based on the previous findings that ON pathway defects are known to be associated with rod system dysfunction [27]. Therefore, the ON pathway function can potentially provide a surrogate marker of rod function, which is typically difficult to measure without dark adaptation and elaborate individual calibration [2830].Thus the implications of the test go well beyond the assessment of ON and OFF visual pathways.

The limitations of the study are that the test was not carried out in a controlled lab-based setup. The external lighting under which, the test was conducted was not uniform across all the participants. However, such effect on the results is expected to be minimal, as the test is primarily dependent on the luminance of the iPad screen. The angle at which the device held during the test was not fixed. However, most participants would hold at an angle that they would hold reading material. Also, there is no fixation monitor to track participants’ eye movements, however, the subjects were instructed to keep looking towards the centre of the screen throughout the test. There was no ‘pause’ option available during the test. Therefore, the effect of fatigue on reaction times cannot be ruled out.

Conclusions

The test has several advantages such as easy-to-use, portability and being less time-consuming. This is the first study to establish a wide age-related normative database for this tablet-based test, which is important, because it allows us to distinguish age-related changes from disease-specific defects. This test will be especially useful in rod-dominated diseases, where ON pathway parameter can potentially act as a easy-to-use surrogate marker of rod photoreceptor function as shown in pilot data so far [31] in lieu of long adaptation tests. Future studies should iterate and identify the optimum ‘number of trials’ required to balance between the need for robust data and the time taken for test completion.

Acknowledgments

We would like to acknowledge Hyderabad Eye Research Foundation for the infrastructure support to carry out the project.

References

  1. 1. Hartline HK. The response of single optic nerve fibers of the vertebrate eye to illumination of the retina. Am J Physiol Content. 1938;121: 400–415.
  2. 2. Schiller PH. Central connections of the retinal ON and OFF pathways. Nature. 1982;297: 580–583. pmid:7088141
  3. 3. Jin JZ, Weng C, Yeh CI, Gordon JA, Ruthazer ES, Stryker MP, et al. On and off domains of geniculate afferents in cat primary visual cortex. Nat Neurosci. 2008;11: 88–94. pmid:18084287
  4. 4. Jin J, Wang Y, Swadlow HA, Alonso JM. Population receptive fields of on and off thalamic inputs to an orientation column in visual cortex. Nature Neuroscience. Nat Neurosci; 2011. pp. 232–240. pmid:21217765
  5. 5. Wang Y, Jin J, Kremkow J, Lashgari R, Komban SJ, Alonso JM. Columnar organization of spatial phase in visual cortex. Nat Neurosci. 2015;18: 97–103. pmid:25420070
  6. 6. Kremkow J, Jin J, Komban SJ, Kremkow J, Jin J, Komban SJ, et al. Neuronal nonlinearity explains greater visual spatial resolution for darks than lights. Proc Natl Acad Sci. 2014;111: 3170–3175. pmid:24516130
  7. 7. Komban SJ, Kremkow J, Jin J. Neuronal and perceptual differences in the temporal processing of darks and lights. Neuron. 2014;82: 224–234. pmid:24698277
  8. 8. Zhao L, Sendek C, Davoodnia V. Effect of age and glaucoma on the detection of darks and lights. Invest Ophthalmol Vis Sci. 56: 7000–7006. pmid:26513506
  9. 9. Alexander KR, Fishman GA, Peachey NS, Marchese AL, Tso MO. ‘On’response defect in paraneoplastic night blindness with cutaneous malignant melanoma. Invest Ophthalmol Vis Sci. 1992;33: 477–483. pmid:1544774
  10. 10. Pons C, Jin J, Mazade R, Dul M, Zaidi Q, Alonso JM. Amblyopia Affects the ON Visual Pathway More than the OFF. J Neurosci. 2019;39: 6276–6290. pmid:31189574
  11. 11. Hathibelagal AR, Bharadwaj SR, Yadav AR, Subramanian A, Sadler JRE, Barbur JL. Age-related change in flicker thresholds with rod-and cone-enhanced stimuli. PLoS One. 2020;15: e0232784. pmid:32639956
  12. 12. Hathibelagal AR, Bharadwaj SR, Jalali S, Subramanian A, Barbur JL. Evaluation of photoreceptor function in inherited retinal diseases using rod‐and cone‐enhanced flicker stimuli. Ophthalmic Physiol Opt. 2021. pmid:33834501
  13. 13. Yadav G, Narayanan R, Hathibelagal AR. Chromatic and flicker threshold changes in age-related macular degeneration following anti-VEGF treatment. Clin Exp Optom. 2021; 1–7. pmid:33941047
  14. 14. Chylack LT, Wolfe JK, Singer DM, Leske MC, Bullimore MA, Bailey IL, et al. The lens opacities classification system III. Arch Ophthalmol. 1993;111: 831–836. pmid:8512486
  15. 15. Komban SJ, Alonso JM, Q Z. Darks are processed faster than lights. J Neurosci. 2011;31: 8654–8658. pmid:21653869
  16. 16. Zemon V, Gordon J, Welch J. Asymmetries in ON and OFF visual pathways of humans revealed using contrast-evoked cortical potentials. Vis Neurosci. 1988;1: 145–150. pmid:3154786
  17. 17. Pons C, Mazade R, Jin J, Dul MW, Zaidi Q, Alonso JM. Neuronal mechanisms underlying differences in spatial resolution between darks and lights in human vision. J Vis. 2017;17. pmid:29196762
  18. 18. Pandarinath C, Victor JD, Nirenberg S. Symmetry breakdown in the ON and OFF pathways of the retina at night: functional implications. J Neurosci. 2010;30: 10006–10014. pmid:20668185
  19. 19. Ahmad KM, Klug K, Herr S, Sterling P, Schein S. Cell density ratios in a foveal patch in macaque retina. Vis Neurosci. 2003;20: 189–209. pmid:12916740
  20. 20. Ratliff CP, Borghuis BG, Kao Y-H, Sterling P, Balasubramanian V. Retina is structured to process an excess of darkness in natural scenes. Proc Natl Acad Sci. 2010;107: 17368–17373. pmid:20855627
  21. 21. Balasubramanian V, Sterling P. Receptive fields and functional architecture in the retina. J Physiol. 2009;587: 2753–2767. pmid:19525561
  22. 22. Westheimer G, Chu P, Huang W, Tran T, Dister R. Visual acuity with reversed-contrast charts: II. Clinical investigation. Optom Vis Sci. 2003;80: 749–752. pmid:14627941
  23. 23. Woods DL, Wyma JM, Yund EW, Herron TJ, Reed B. Age-related slowing of response selection and production in a visual choice reaction time task. Front Hum Neurosci. 2015;9: 1–12. pmid:25653611
  24. 24. Van Halewyck F, Lavrysen A, Levin O, Boisgontier MP, Elliott D, Helsen WF. Both age and physical activity level impact on eye-hand coordination. Hum Mov Sci. 2014;36: 80–96. pmid:24964357
  25. 25. Devaney KO, Johnson HA. Neuron Loss in the Aging Visual Cortex of Man. J Gerontol. 1980;35: 836–841. pmid:7440924
  26. 26. Peirce J, Gray JR, Simpson S, MacAskill M, Höchenberger R, Sogo H, et al. PsychoPy2: Experiments in behavior made easy. Behav Res Methods. 2019;51: 195–203. pmid:30734206
  27. 27. Nelson R, Kolb H. ON and OFF pathways in the vertebrate retina and visual system. Vis Neurosci. 2004;1: 260–278.
  28. 28. Hathibelagal AR, Feigl B, Cao D, Zele AJ. Extrinsic cone-mediated post-receptoral noise inhibits the rod temporal impulse response function. JOSA A. 2018;35: B72–B77. pmid:29603925
  29. 29. Hathibelagal AR, Feigl B, Kremers J, Zele AJ. Correlated and uncorrelated invisible temporal white noise alters mesopic rod signaling. J Opt Soc Am A. 2016;33: A93–A103. pmid:26974946
  30. 30. Hathibelagal AR, Feigl B, Zele AJ. Correlated cone noise decreases rod signal contributions to the post-receptoral pathways. JOSA A. 2018;35: B78–B84. pmid:29603926
  31. 31. Hathibelagal AR, Bhutia P, Das M, Babu H, GaneshRao SB. Larger ON-pathway deficits in rod-dominated disease than cone-dominated disease. J Vis. 2022;22: 1.