Figures
Abstract
Estimating the contact angle of a virus infected saliva droplet is seen to be an important area of research as it presents an idea about the drying time of the respective droplet and in turn of the growth of the underlying pandemic. In this paper we extend the data presented by Balusamy, Banerjee and Sahu [“Lifetime of sessile saliva droplets in the context of SARS-CoV-2,” Int. J. Heat Mass Transf. 123, 105178 (2021)], where the contact angles are fitted using a newly proposed half-circular wrapped-exponential model, and a sequential confidence interval estimation approach is established which largely reduces both time and cost with regards to data collection.
Citation: Bapat SR (2021) Sequentially estimating the dynamic contact angle of sessile saliva droplets in view of SARS-CoV-2. PLoS ONE 16(12): e0261441. https://doi.org/10.1371/journal.pone.0261441
Editor: Etsuro Ito, Waseda University: Waseda Daigaku, JAPAN
Received: October 19, 2021; Accepted: November 24, 2021; Published: December 22, 2021
Copyright: © 2021 Sudeep R. Bapat. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: The associated data has been uploaded to the OSF repository. A view only link to the data is as follows: https://osf.io/xz5md/?view_only=50bb01f67fe34eaba12da776beb76f86.
Funding: The author received no specific funding for this work.
Competing interests: The authors have declared that no competing interests exist.
Introduction
SARS-CoV-2 (virus which causes COVID-19) has severely impacted more than 200 countries worldwide, with over 180 million cases until the end of June, 2021. The span of this virus was so fast and devastating that the World Health Organization declared the outbreak as a Public Health Emergency of International Concern on 30 January, 2020, whereas a global pandemic on 11 March, 2020. Spreading of such respiratory diseases is largely caused due to respiratory droplets of saliva (of an infected person) during coughing, sneezing or even moist speaking. A recent reference paper in this regard is by [1]. Understanding the lifetime of such droplets is hence an important area of research, which could be handled by studying the fluid dynamics of such droplets in air. One may refer to [2] who analyze the flow-physics of virus laden respiratory droplets, or [3] who analyze the likelihood of survival of a virus laden droplet on a solid surface. Further, it has been studied that such respiratory droplets have a tendency to increase their lifetime on coming in contact with a surface based on its properties. [4] studied the physico-chemical characteristics of evaporating respiratory fluid droplets and found out that a typical saliva droplet also contains NaCl, mucin (protein) and a certain surfactant in fixed amounts. In addition to the droplet composition, the evaporation rate of a droplet also depends on environmental conditions and factors such as temperature, relative humidity, droplet volume and the contact angle which the droplet makes with the surface. A specific analysis was carried out in [3] where the authors examined the drying time of a deposited droplet in two different temperatures namely, 25°C and 40°C which represent an air-conditioned room and a summer afternoon respectively. The contact angle and humidity were set at 30° and 50%. Studying the drying time of a droplet plays an important role as it well related to the the survival of the droplet and in turn to the growth of the pandemic. [5] tested this hypothesis using suspended droplets in air, whereas [3] compared the growth of infection with the drying time in different cities globally. They verified that for a 5 nL droplet, a higher drying time corresponds to a higher pandemic growth rate. Hence, when a droplet evaporates slowly, the chance of the survival of the virus is enhanced.
Specifically, the initial contact angle, which measures the angle that a droplet makes with the surface plays a big role in determining the lifetime of it. Different contact angles are predominant with different surfaces i.e., droplets on glass, wood, stainless steel, cotton or the touchscreen of a smartphone tend to make angles varying from 5° to 95°. It is also intuitive that a contact angle cannot exceed 180°. Fig 1 contains pictorial representations of two different droplets making different angles with the surface. The left image shows a water droplet on cloth, making a high contact angle due to the hydrophobic property of the cloth. Whereas the image on the right shows a water droplet on a lotus leaf, again making a high contact angle. Both the images are borrowed from Wikipedia under the license CC BY-SA 3.0.
Both the images are borrowed from Wikipedia under the license CC BY-SA 3.0. (a) water drop on cloth (b) water drop on a lotus leaf.
A dynamic contact angle is the one which is measured as the droplet changes its size as it moves quickly over the surface. One may again refer to [3] or [1] for more details. However it is also true that measuring such contact angles (initial or dynamic) involves a lot of struggle and cost, as it has to be carried out using heavy apparatus. Some of the existing methods for contact angle determination include the sessile droplet method, where the angle is measured using a “contact angle goniometer”, the pendant drop method which is used to measure angles for pendant drops, the dynamic sessile drop method which is similar to a sessile drop method but requires the drop to be modified or a single-fiber meniscus method where the shape of the meniscus on the fiber is directly imaged through a high resolution camera. One may refer to [6] for an overview of other techniques. Hence to estimate a dynamic contact angle of a droplet, a reduction in the number of observations required to carry out the estimation is highly beneficial. In this paper, we thus introduce an appropriate sequential estimation technique.
Now since the aim of this paper is to estimate a certain contact angle, it makes more sense to apply a circular model rather than a usual linear one on the concerned data. Literature on such models is vast and ever expanding. A few other examples where a circular model is appropriate involve orientations of the major axis of termite mounds, the angles of slope of different sedimentary layers of an exposed rock-face or the walking directions of long legged desert ants etc. In all these examples, the observations are either certain directions, or angles measured in degrees or radians. Such observations are often measured either clockwise or counter-clockwise from some reference direction, usually called as the zero direction. Over years, a usual technique to design new circular distributions is to wrap a linear distribution over a full circle. However as seen before, since the contact angles of any droplet is necessarily less than 180°, an adjusted model which is capable of taking values only on half-a-circle seems more appropriate. In this context, we introduce a new model called as the half-circular wrapped-exponential distribution to model our data. In general, a few notable books covering circular models which one can refer to are by [7–10], among others.
Data modeling and analysis
The particular dataset analyzed for this experiment is a pseudo dataset which is an extended version of the one borrowed from [1] and consists of the temporal variations of the dynamic contact angles in degrees (simply called as contact angles from now on) of the droplet normalized with the initial contact angle, θ/θ0. The particular setting used for this experiment is as follows: the relative humidity (RH) is controlled at 50%, the initial droplet volume (V0) is 10 nL, the molality of the saliva (M) is 0.154 mol/kg, temperature (T) is 30°, the surfactant parameter (Ψ) is 10 and the initial contact angle (θ0) is 50°. One may refer to Fig 2a in [1] for a pictorial description of the dataset. As there was not an access to the actual observations, we adopted the following approach: for brevity alone, we only focused on the curve representing RH = 50%. Using an online tool, we extracted the (x, y) coordinates for each of its 20 observations. We converted these normalized contact angles to actual contact angles (θ) and finally translated those into radians. Table 1 lists all these observations for convenience. Now, to include more observations in the analysis, we first assumed a linear relationship between “time” and “contact angles” (CA), fitted several polynomial regression models and picked the following third-order model which fitted better with a R2 value of 0.9613.
(1)
Fig 2 contains a scatterplot of the raw data (a) and the fitted polynomial regression model superimposed on it (b).
We then assumed a vector of times ranging over 5–300 seconds with a jump of 1 second in between, and predicted the contact angles according to the above model. Thus, our final pseudo dataset consists of 296 observations according to our construction.
A half-circular wrapped-exponential model for the contact angles
For a start, Fig 3 shows a pictorial distribution of our pseudo data placed around a circle. Purposefully, we have stacked the closely lying observations for a better visualization and as one can observe, all the observations lie entirely between 0 and π/2 radians. As seen before, wrapping a linear density over a circle is a suitable choice to model such observations. In this case, since the linear curve seen in Fig 2 shows an exponential decline, it makes sense to choose some of the lifetime distributions and wrapping them around a circle. Now as discussed before, since any contact angle of a droplet is always less than π radians it makes more sense to fit a distribution which takes values only on a semicircle. In literature, not many such distributions have been proposed. One such example is of a half-circular distribution which was introduced by [11], who converted a Gamma distribution to a half-circular one and fitted it to the angle which measures the posterior corneal curvature of an eye. In a similar spirit, we now introduce a half-circular wrapped-exponential (HCWE) distribution with parameter λ. An intuitive construction is through the following transformation: Xw = X(modπ), where X is a linear exponential random variable with pdf f(x) = λe−λx, x > 0, λ > 0. Interestingly, another easy construction is to simply truncate X over [0, π). Its pdf, cdf and characteristic functions are as follows,
(2)
(3)
(4)
Consequently, the mean direction happens to be,
(5)
Now for a comparison, we tried to fit several other wrapped distributions to the data namely, the wrapped-exponential by [12], transmuted wrapped-exponential by [13] and wrapped-Lindley by [14]. For completeness, we also fit a von-Mises distribution which is one of the widely used circular models. Table 2 contains the log-likelihood values and the AICs for these five models. As one can observe, the half-circular wrapped-exponential model fits better than the others. It is also seen to be a significant fit with a p-value of 0.18 using the Kolmogorov-Smirnov test, and the estimated λ value equals 3.69. On using Eq (5), the estimated mean direction equals 0.2646 radians. Fig 4 contains a set of goodness of fit plots for the HCWE(λ) distribution. All these fits and plots were carried out using the “circular” and “fitdistrplus” packages in R.
Now, since in practice the value of λ will be unknown, we develop a sequential fixed-width confidence interval to estimate λ which in turn will give us an estimate for the mean direction μ0 of the contact angle, which will give us a fair idea about the drying time of the droplet.
A sequential fixed-width confidence interval
In general, a sequential rule consists of identifying a stopping variable, which determines the optimal sample size to be used in the experiment. This technique largely reduces the number of observations needed for the inference part, which proves to be beneficial as it reduces both time and cost. Literature on sequential estimation methodologies is vast and still being explored. In particular, a few recent works aimed at finding appropriate confidence intervals include, [15], who developed a general sequential fixed-accuracy confidence interval, [16], who looked at constructing bounded length intervals, [17, 18] who constructed fixed-accuracy intervals for parameters under an inverse Gaussian and bivariate exponential models or [19], who derived fixed-accuracy intervals for the reliability parameter of an exponential distribution.
To summarize, a fixed-width interval (FWI) aims at simultaneously controlling the width of the interval (say, d) and the confidence limit (1−α). Such an interval is clearly symmetric around the parameter. It turns out that there does not exist any fixed sample size procedure to tackle this problem and one has to resort to a sequential setup. However, a certain drawback of this method is: even though a parameter is entirely positive, the lower bound of a FWI can assume negative values. A fix to this is to construct a fixed-accuracy interval (FAI), which assumes a fixed-accuracy value (say, d). A FAI happens to be symmetric around log of the parameter. An introductory paper to this approach is [15]. Even in this case it may happen, that if the parameter space is bounded (say from above by U), a FAI may contain bounds which cross U. Hence, [15] came up with a bounded-length fixed-accuracy interval (BLFAI) as a fix. In our case, we aim at constructing a fixed-width interval as outlined next.
Let θ1, θ2, … be the dynamic contact angles of a droplet, measured using a suitable technique. Then, for some pre-fixed width d, a confidence interval of λ takes the following form,
(6)
where
is the MLE of λ, which is consistent and asymptotically normal with the following representation,
(7)
where
is the variance of the MLE and
stands for convergence in distribution. Now, for In to include λ with a pre-fixed coverage probability 1 − α, the required fixed sample size can be found out as follows,
(8)
where zα/2 is the upper 100(α/2)% point of a standard normal distribution. Since n* is an unknown quantity, we now propose the following sequential methodology:
We first fix an integer m(> 1) often called as the “pilot sample size” and obtain a pilot sample θ1, θ2, …, θm from a HCWE(λ) density as given in Eq (2). We then aim to collect an additional observation at every stage, until sampling is terminated according to the following stopping rule:
(9)
where
is the estimated variance of the MLE. We then have a final set of observations θ1, θ2, …, θN and will estimate λ using the interval,
(10)
The stopping variable N from Eq (9) follows properties such as asymptotic first-order efficiency and asymptotic consistency. We leave out the proofs for brevity. One may refer to Theorem 3.1 of [17]. Finally, we estimate the mean direction μ0 using an interval,
(11)
We now outline a stepwise procedure to tackle a practical problem through the above methodology.
- Step 1: For a certain specific liquid droplet, observe the contact angles over equally spaced time intervals and note down the first m angles (θ1, θ2, …, θm) over the first m time points t1, t2, …, tm.
- Step 2: After tm, collect observations (i.e. observe contact angles) one-at-a-time according to the stopping rule given in Eq (9).
- Step 3: Once the stopping rule is executed, observe the value of N, find out an interval for λ as per Eq (10) and ultimately find a subsequent interval for the mean direction μ0 according to Eq (11).
- Step 4: Using the interval for μ0, find out a rough interval for the average drying time of the droplet by predicting using the following inverted polynomial regression model (R2 = 0.98) (i.e. by assuming “time” as the response and “contact angle” as the predictor.
Hence, for our complete pseudo data, and the estimated drying time equals 115.13 seconds. We now apply the above procedure to our observed pseudo data with a small adjustment: we first randomize the entire data, sample 250 observations, and sort them. This kind of an approach gives a good representation of the actual data in every simulation. We consider several fixed values of d ranging from 0.05 to 0.6 over roughly equally spaced intervals. We fix the pilot sample size m = 5 and the significance level α = 0.05. After implementing the sequential rule Eq (9) with a particular choice of d, we obtain the confidence interval for λ and in turn report the interval for μ0, and finally an interval for the average drying time of the droplet. Since the procedure has to be solved analytically, all the analyses were carried out again using the “fitdistrplus” package in R.
A few take away points from Table 3 are: as one goes on increasing d, naturally, the width of the desired interval increases and as a result, less number of observations are required to achieve a confidence level of α (0.05 in this case). Also, for increasing N, the intervals for the drying time also increase and are seen to approach the actual estimated drying time of 115.13 seconds. But of course, a larger sample size comes with a cost and hence one needs to strike a proper balance.
Conclusion
In this paper we have established a sequential confidence interval methodology to estimate the dynamic contact angle of a sessile saliva drop. This will help the researchers and practitioners to build an idea about the growth of the pandemic in general or by focusing on specific countries. Since a contact angle has to be measured using a heavy-duty apparatus, a sequential rule also appears to be beneficial by offering a reduction in time and cost. We introduced a new circular model called as the half-circular wrapped-exponential distribution to model the angles, which can only spread over half a circle. This new model was seen to fit better than some of the existing ones in the literature. Depending on the width d of the interval fixed by the experimenter, the mean contact angle of the droplet was seen to be between 0.41 and 0.56 radians or 23.49 and 32.08 degrees. On the other hand the drying time of the saliva droplet was seen to be between 61 and 80 seconds.
Acknowledgments
The author sincerely thanks the anonymous referee and the Editor for their valuable comments and suggestions.
References
- 1. Balusamy S, Banerjee S, Sahu KC. Lifetime of sessile saliva droplets in the context of SARS- CoV-2. Int J Heat Mass Trasf. 2021; (123).
- 2. Mittal R, Ni R, Seo JH. The flow physics of COVID-19. J Fluid Mech. 2020; (894).
- 3. Bhardwaj R, Agrawal A. Likelihood of survival of coronavirus in a respiratory droplet deposited on a solid surface. Phys Fluids. 2020; 32(6).
- 4. Vejerano EP, Marr LC. Physico-chemical characteristics of evaporating respiratory fluid droplets. Interface. 2018; 15(139). pmid:29491178
- 5. Chaudhuri S, Basu S, Kabi P, Unni VR, Saha A. Modeling ambient temperature and relative humidity sensitivity of respiratory droplets and their role in determining growth rate of COVID-19 outbreaks. Phys Fluids. 2020; 32.
- 6. Albert E, Tegze B, Hajnal Z, Zámbó D, Szekrényes DP, Déak A, et al. Robust contact angle determination for needle-in-drop type measurements. ACS Omega. 2019; 4:18465–18471. pmid:31720550
- 7.
Mardia KV, Jupp PE. Directional statistics. 2nd Ed. New York: Wiley.
- 8.
Rao JS and Sengupta A. Topics in circular statistics. New York: World Scientific.
- 9.
Rao AVD, Girija SVS. Angular statistics. Boca Raton: CRC Press.
- 10.
Ley C, Verdebout T. Applied directional statistics. Boca Raton: CRC Press.
- 11. Rambli A, Mohamed I, Shimizu K, Ramli N. A half-circular distribution on a circle. Sains Malay. 2019; 48(4):887–892.
- 12. Rao JS, Kozubowski TJ. New families of wrapped distributions for modeling skew circular data. Comm Stat Theo Meth. 2004; 33(9):2059–2074.
- 13. Yilmaz A, Biçer C. A new wrapped exponential distribution. Math Sci. 2018; (12):285–293.
- 14. Joshi S, Jose KK. Wrapped Lindley distribution. Comm Stat Theo Meth. 2018; 47(5):1013–1021.
- 15. Banerjee S, Mukhopadhyay N. A general sequential fixed-accuracy confidence interval estimation methodology for a positive parameter: Illustrations using health and safety data. Ann Inst Stat Math. 2016; (68):541–571.
- 16.
Mukhopadhyay N, Banerjee S. Purely sequential and two-stage bounded-length confidence intervals for the Bernoulli parameter with illustrations from health studies and ecology. Choudhary PK et al. (eds.), Ordered Data Analysis, Modeling and Health Research Methods. Springer Proceedings in Mathematics & Statistics 149.
- 17. Bapat SR. On purely sequential estimation of an inverse Gaussian mean. Metrika. 2018; (81):1005–1024.
- 18. Bapat SR. Purely sequential fixed accuracy confidence intervals for P(X > Y) under bivariate exponential models. Am J Math Manag Sci. 2018; (37):386–400.
- 19. Khalifeh A, Mahmoudi E, Chaturvedi A. Sequential fixed-accuracy confidence intervals for the stress-strength reliability parameter for the exponential distribution: two-stage sampling procedure. Comp Stat. https://doi.org/10.1007/s00180-020-00957-5.