Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Effect of proximal box elevation on fracture resistance and microleakage of premolars restored with ceramic endocrowns

  • Hong Zhang,

    Roles Conceptualization, Writing – review & editing

    Affiliation Hospital of Stomatology, Jilin University, Changchun, P.R China

  • He Li,

    Roles Formal analysis, Methodology

    Affiliation Hospital of Stomatology, Jilin University, Changchun, P.R China

  • Qian Cong,

    Roles Resources, Writing – review & editing

    Affiliation Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, P.R China

  • Zhimin Zhang ,

    Roles Methodology, Writing – review & editing

    azhangzm2019@yandex.com

    Affiliation Hospital of Stomatology, Jilin University, Changchun, P.R China

  • Aobo Du,

    Roles Data curation, Investigation

    Affiliation Hospital of Stomatology, Jilin University, Changchun, P.R China

  • Ying Wang

    Roles Data curation, Formal analysis

    Affiliation Hospital of Stomatology, Jilin University, Changchun, P.R China

Correction

23 Sep 2021: Zhang H, Li H, Cong Q, Zhang Z, Du A, et al. (2021) Correction: Effect of proximal box elevation on fracture resistance and microleakage of premolars restored with ceramic endocrowns. PLOS ONE 16(9): e0258038. https://doi.org/10.1371/journal.pone.0258038 View correction

Abstract

Background

Restoration of endodontically treated premolar is in high risk for biomechanical failure, and often presents with subgingival margins. Proximal box elevation (PBE) has been used to relocate subgingival cavity outlines.

Objective

To evaluate the influence of PBE on fracture resistance and gingival microleakage of premolars with endodontic access cavities following ceramic endocrown.

Methods

Eighty sound maxillary premolars with standardized Class II cavities on mesial surfaces were randomly assigned to four groups (n = 20 in each group). Groups E1, E2 and E3, with proximal margins located in dentin/cementum, 2 mm below the cemento-enamel junction (CEJ), simulated subgingival location. Group E4 (supragingival group), with proximal margins located in enamel, 1 mm above the CEJ, was used as the positive control. For margin elevation of the proximal cavities, bulk-fill Smart Dentin Replacement (SDR), a visible light cured resin composite, was applied in group E1, and conventional resin composite (3M Z350 XT, a light-activated composite) was placed in group E2. Group E3 was only treated with a ceramic crown and served as the negative control. In all groups, computer-aided design (CAD) ceramic endocrowns were adhesively inserted, and fracture resistance, failure mode and microleakage were evaluated.

Results

A higher fracture resistance value was observed in PBE groups E1 and E2, regardless of the materials used (P = 0.038, and 0.010, respectively, vs E3), and fracture resistance in group E1 was higher than that in group E2. In teeth without PBE, the percentage of catastrophic failures reached 70%. Compared to group E3, a lower frequency distribution of microleakage was detected in supragingival group E4 (P = 0.031). No increased percentage of microleakage was observed in groups treated with PBE.

Conclusion

For endodontically treated maxillary premolars restored with ceramic endocrowns, PBE increases fracture resistance but not microleakage.

Introduction

Because of the high risk of biomechanical failure, restoration of endodontically treated premolars remains a challenge in prosthetic and restorative dentistry [1]. Teeth may fracture due to the decrease of water content, and the absence of structural integrity associated with deep dental caries, trauma, or restorative and endodontic procedures [2, 3]. Additionally, endodontically treated teeth with deep proximal defects display maximal tooth fragility [4]. To minimize risk of fracture, premolar under endodontic therapy is suggested to follow full-coverage restorations [5].

Computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic endocrown with minimally invasive preparations has been used for restoring endodontically treated teeth rather than post-core techniques [6]. Fiber post placement is efficacious to reduce failures of postendodontic restorations only with teeth that exhibit no coronal walls. Post insertion for teeth showing a minor substance loss should be critically reconsidered [7, 8]. However, because proximal defects are often located beneath gingiva, it is difficult for impression taking, rubber dam application, and adhesive cementation [9, 10]. Dry condition during cementation is also required, but marginal microleakage is hard to control [11]. A less invasive method to set cavity margins supragingivally was brought up by Dietschi et al. (1998) using a composite layer covered with an indirect ceramic restoration. This approach is commonly referred to as proximal box elevation (PBE) which is to set an intra-crevicular to a supragingival level by a proper resin composite onto the existing margin, similar mechanism like deep margin elevation [1215]. After resetting the cavity margins to the supragingival level, a rubber dam is applied to maintain a dry working field, thus significantly facilitating PBE physical applications [16].

Polymerization of the composite layer is often accompanied by substantial volumetric shrinkage. This shrinkage may cause marginal leakage, secondary caries, cuspal deflection, which may be associated with microleakage and marginal staining at the tooth/restoration interface, leading to adhesion failure [1720]. Previous studies suggested that a resin composite with bulk-fill technique exhibits several advantageous properties such as low polymerization shrinkage, low microleakage, good color stability, and low water sorption and solubility [21]. A few data demonstrated how a resin composite layer for PBE impacts fracture and marginal microleakage of root canal treated premolar with indirect restorations [2225]. So, based on previous findings, we hypothesized that PBE technique is feasible following ceramic endocrown. However, how PBE with a resin composite impact the marginal quality and fracture behavior of premolars restored with CAD/CAM endocrowns remains unclear. In this study, we aimed to explore the effects of PBE technique on fracture resistance, marginal microleakage in premolars with CAD/CAM endocrowns, and to evaluate the difference of two kinds of materials in the relocation of the cervical margin.

Materials and methods

Specimen collection and preparation

This study was approved by the Ethics Committee of Jilin University, China on September 3rd, 2016 (No.2016-025). Signed informed consent was also obtained from all adult patients who needed teeth extraction. Eighty complete and caries-free human premolars were immersed in 0.1% thymol solution (Sigma-Aldrich, St. Louis, MO, USA) after extraction, and used in this in vitro study. After cleaning, the premolars were randomly allocated to four groups (n = 20 in each group). Root canal preparation was done with rotary instruments ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland) until the apical size reached ISO 30. The root canals were vertically filled with condensed gutta-percha (BeeFill, VDW, München, Germany) and an epoxy sealer (AH-Plus, DentsplyDe Trey, Konstanz, Germany). Standardized mesial-occlusal (MO) Class II cavities were designed as follows: 5 mm in buccal-lingual extension, 2 mm width at the cervical area. In groups E1, E2 and E3, all cervical margins were set 2 mm below cemento-enamel junction (CEJ), and 3 mm below CEJ in group E4. A 3 mm thick bulk-fill SDR flowable composite (Dentsply Caulk, Milford, DE, USA) was applied in group E1, and 1.5 mm thick Filtek Z350 XT conventional resin composite (3 M ESPE, St Paul, MN, USA) was used in group E2. At the same time, two increments were used to simulate PBE with a periodontal probe (Kang Qiao, Alton (Shanghai) Medical Instruments, Shanghai, China) in both group E1 and E2. In group E3, all cervical margins were left untreated. In group E4, enamel margins were treated with 37% phosphoric acid (Monobond Plus, Ivoclar Vivadent, Schaan, Liechtenstein) for 30 s, rinsed with water for 30 s, and then gently dried with air. Immediate dentin sealing (IDS) techniques were applied, and a Tetric N-Bond self-etching adhesive resin (Monobond Plus, Ivoclar Vivadent, Schaan, Liechtenstein) was applied to the dentin surface and left in place for 20 s. Excess solvent was removed by air-drying for 3 S. The bonding, together with a resin composite, was light cured using an LED polymerization device (SmartLite Focus, Dentsply Sirona, Ballaigues, Switzerland) at 1,200 mW/cm2 for 40 s. After placing the proximal composite layers, the cervical boxes of the MO-cavities were set 1 mm above CEJ in groups E1 and E2. The shape of cavities and composite increments of all groups are shown in Fig 1.

thumbnail
Fig 1. Restoration designs used in this study.

Groups E1, E2 and E3, with proximal margins located in dentin/cementum, subgingival. Group E4 (supragingival group), with proximal margins located in enamel above the CEJ, as the positive control. Group E1 was with bulk-fill Smart Dentin Replacement, and E2 with conventional resin composite. Group E3 was treated with a ceramic crown, as the negative control.

https://doi.org/10.1371/journal.pone.0252269.g001

The endocrowns were designed and machined with the Cerec CAD/CAM system (D4DTechnologies, Richardson, TX, USA), showing all contact points and articulation for correct dynamic occlusion. The endocrown preparation consisted of deepening the central retention cavity, and extending 5 mm in depth from the occlusal floor with round internal line angles. A 2 mm reduction of the buccal and lingual cusps was done on all teeth. Internally, a flowable material (Filtek TM Supreme XTE Flowable; 3M ESPE, St. Paul, MN, USA) was used to seal the root canal and plan the chamber wall. A smooth chamber wall and divergent axial walls were preserved 8 degree towards the occlusal surface. The endocrown was gently positioned with finger pressure.

All cavity walls were polished, and sharp inner corners were rounded. Ceramic endocrowns were made using the CEREC 3D CAD-CAM unit (Sirona Dental Systems, Bensheim, Germany) and produced from lithium disilicate reinforced ceramic (IPS e.max CAD; Ivoclar Vivadent, Schaan, Liechtenstein). After adjustment, the internal surface of the restoration was rinsed with 96% ethanol (Tianyu, Jilin, China) and air-dried. To improve the strength, all the surfaces were etched with 5% hydrofluoric acid (Ivoclar Vivadent, Schaan, Liechtenstein) for 1 min, and then washed with air/water for 30 s. Silane (Ivoclar Vivaddent, Schaan, Liechtenstein) was used for 1 min and air dried. Before cementation, the resin composites for PBE in groups E1 and E2 were pre-treated with air abrasion (CoJet, 30 mm; 3M ESPE Platz, Seefeld, Germany) for 5 s, followed by an extensive clean with water spray. 37% phosphoric acid (Ivoclar Vivadent, Schaan, Liechtenstein) was spread on the enamel for 30 s and dentin for 15 s. The resin composites in groups E1 and E2 were then silanized (Monobond-S, IvoclarVivadent, Schaan, Liechtenstein), and dried without air-blow. Then the bonding system (Tetric N-Bond, Ivoclar Vivadent, Schaan, Liechtenstein) was used as described above for all groups. All endocrowns were luted with dual-cured Variolink II luting resin composite cement (Ivoclar Vivadent, Schaan, Liechtenstein), and then cemented. The surface was finished and polished with disks (Sof-Lex Pop-On; 3M ESPE, St. Paul, MN, USA) in decreasing granulations.

Fracture resistance testing

Samples in each group were tested for fracture resistance. The roots of selected samples were covered with a 0.3 mm gum resin layer (Impregum Penta Soft, 3M ESPE, Seefeld, Germany) to simulate a periodontal ligament, and subsequently embedded in self-curing acrylic resin (Shanghai Dental Material Company, shanghai, China). The restoration margins were set approximately 2 mm above the feigned bone level. All restored specimens were stored in distilled water in the dark at 37°C for 72 h. Repeated mechanical stress was applied to all specimens under a computer-controlled masticator (custom made; Jilin University, Jilin, China) for 1,200,000 cycles, using tungsten carbide spheres (5.0 mm radius of curvature) of 49 N at 1.7 Hz [26], and simulating approximately 5 years of clinical usage. Then, all samples were placed vertically to the long axis of the tooth for fixation in a universal testing machine (NTS Technology, Tokyo, Japan), to produce a static compression force onto the tooth by a 5 mm steel sphere. The crosshead speed was set at 0.05 mm/s until fracture occurred.

Fractures were divided into two categories: favorable failures were repairable fractures above the level of bone recreation, and unfavorable failures were catastrophic fractures below the level of bone simulation. The numbers and percentage of each fracture were recorded.

Microleakage testing

After cementation of the crowns for 1 h, the remaining specimens were immersed in water at room temperature for 24 h before thermocycling. The teeth were thermocycled using 500 cycles from 5°C to 55°C with a dwell time for 30 s under a thermocycling device (TC-501F; Weier, Suzhou, China) [27]. After thermocycling, the teeth were then covered with two coats of nail varnish 1 mm beyond the margins of the crown and immersed in 0.55% methylene-blue dye solution (Sigma-Aldrich, St. Louis, MO, USA) for 24 h at room temperature, followed by tap water washing for 10 min. PBE with the endocrowns was embedded in acrylic resin. And the teeth were split mesiodistally using a diamond wheel saw (Model SYJ-150A; Shenyang Kejing Equipment Manufacturing, Shenyang, China) under water-cooling. Two surfaces from each tooth were evaluated for gingival microleakage under a stereomicroscope (SZ51/61; Olympus, Tokyo, Japan). Dye penetration measurement was started from gingival margins. An independent examiner scored, and another trained examiner confirmed observation. The cervical marginal microleakage was recorded based on the following criteria: score 0 = no dye penetration, score 1 = dye penetration limited to enamel, score 2 = dye penetration beyond CEJ but limited to 2/3 of the cervical wall length, score 3 = dye penetration beyond 2/3 of the cervical wall length but not to the pulpal wall, and score 4 = dye penetration to the pulpal wall [10].

Statistical analysis

SAS version 9.2 (SAS Institute, Cary, NC, USA) was used for data analysis, and data were expressed as mean ± standard deviation (SD). For fracture resistance testing, a one-way analysis of variance (ANOVA) and Bonferroni post hoc multiple comparison tests were used. Failure mode of four groups was analyzed by Chi–Square test using a software program (SPSS version 19.0; IBM, Armonk, NY, USA). For microleakage testing, a Kruskal-Wallis (K-W) test was used to assess differences among groups. Dwass-Steel-Critchlow-Fligner test was used as post hoc to investigate pairwise differences. The significant level was set at 0.05.

Results

Fracture resistance

The fracture resistance for four groups was obtained and shown in Table 1. Fracture resistance level was the highest in group E4, but it was not significantly different from group E1 (P = 0.059). Compared to group E3 (the negative control), fracture resistance level was increased significantly in groups E1 and E2 with PBE, and there was a significance between PBE and groups E1 and E2 (P = 0.010).

thumbnail
Table 1. Results of fracture resistance and fracture modes.

https://doi.org/10.1371/journal.pone.0252269.t001

Failure results are presented in Table 1 and Fig 2. It was suggested that, compared to group E3, resistance was increased and catastrophic fracture was decreased in groups E4 and E1 (both P = 0.020). Group E4 showed the highest resistance and least catastrophic fracture, followed by group E1 with bulk-fill SDR. However, there were no statistical significances between two filled groups E1 and E2 with PBE (P = 0.070) (Table 1). Representative failure types are also listed in Fig 2, showing the worst fracture in group E3 (the negative control), and the least fracture in group E4 (the positive control). Groups E1 and E2 with PBE fractured mainly at interface between dentin/composite layer or within resin composite for PBE, while groups E3 and E4 without PBE fractured from the surface to the interface through all layers vertically (Fig 2).

thumbnail
Fig 2. Images of fractures in different groups.

Groups E1, E2 and E3, with proximal margins located in dentin/cementum, subgingival. Group E4 (supragingival group), with proximal margins located in enamel above the CEJ, as the positive control. Group E1 was with bulk-fill Smart Dentin Replacement, and E2 with conventional resin composite. Group E3 was treated with a ceramic crown, as the negative control.

https://doi.org/10.1371/journal.pone.0252269.g002

Microleakage test results

Microleakage in dentin/cementum margins is presented in Table 2, and representative stereomicroscopic photographs of microleakage in groups E1 to E4 are shown in Fig 3. The highest frequency distribution of score 0 and 1 was detected in the supragingival group E4 (60%), while the highest percentage of score 4 (12%) was found in group E3 (P = 0.026). The positive control group E4 also has the lowest percentage of score 1 (25%, P = 0.010), while group E1 presented a slightly higher frequency of score 2 (P = 0.078).

thumbnail
Fig 3. Representative stereomicroscopic photograph of microleakage in different groups.

Groups E1, E2 and E3, with proximal margins located in dentin/cementum, subgingival. Group E4 (supragingival group), with proximal margins located in enamel above the CEJ, as the positive control. Group E1 was with bulk-fill Smart Dentin Replacement, and E2 with conventional resin composite. Group E3 was treated with a ceramic crown, as the negative control. Magnification used for observation of the specimens under stereomicroscope was 10×.

https://doi.org/10.1371/journal.pone.0252269.g003

thumbnail
Table 2. Frequency distributions of microleakage scores on dentin/cementum margins.

https://doi.org/10.1371/journal.pone.0252269.t002

Discussion

With the development of material technology and clinical techniques, dental restorative treatment of large and deep cavities of posterior teeth has become feasible [28]. This study evaluated the fracture resistance and microleakage of premolars restored with ceramic endocrowns using PBE, and suggested that PBE significantly increases fracture resistance of the premolars, resulting in a more favorable fracture around the junction between the tooth and the material for PBE. A benefit of the PBE technique is that IDS technique can be performed concomitantly. This combined procedure increases retention, decreases marginal leakage, and has better bond strengths [29]. Previous studies have shown that PBE technique significantly increases the resistance of the restoration to fracture under a compressive load [30, 31]. Our study also revealed that PBE has a higher fracture load regardless of the materials used. The occurrence of high fracture resistance is most likely due to the improvements of the structural support [32]. The fracture patterns of the restored teeth are related to the brittle nature of ceramic. Generally, fracture line below bone level is considered as a non-restorable failure mode, and PBE affects the ratio of irreparable fractures to repairable fractures [33]. In line with previously published reports [33], our findings showed that majority of fracture pattern is vertical fracture from the occlusal fissure, which split the restoration and is located within the restoration or material for PBE. These findings can be explained by the layer of material for PBE, because the material for PBE and endocrown may function as a cohesive unit. Therefore, stress is distributed and PBE groups mainly display restorable failure modes. For ceramic restorations without PBE, fractures happen in the teeth when the force is dispersed through the small cervical structure, and the stress concentrates at the weakest area-the ceramic restoration and tooth interface. The failure mode of two PBE groups is similar, suggesting that the fracture mode depends on the construction in the cervical zone and cuspal inclination [34, 35], rather than the material for PBE.

Microleakage is a major reason of restoration failure [36]. So far, no restorative technique eliminates microleakage in gingival walls. It was reported that no difference was discovered in margin quality of ceramic restorations in dentin regardless of PBE [9, 10, 37]. Also, in this study, all testing groups showed some level of microleakage in gingival wall. Compared to E4 group, higher microleakage scores (score 1) were recorded in E3 group. A significant percentage of score 0 (no dye penetration) was found in supragingival group, suggesting the lowest microleakage in supragingival group. To reduce microleakage, new resin monomers with low polymerization shrinkage are suggested. Both bulk-fill SDR and traditional resin composite were tested, and no significant difference was found between them in this study, which are in accordance with the previous data [3841]. This may be due to the fact that high molecular weight and the conformational flexibility impart optimizes flexibility. Lower dye penetration was reported for bulk-fill SDR [42]. The possible reason is that the thermal expansion coefficient of bulk-fill SDR is closer to the tooth tissue, so the microleakage is less in dentin margins of the cavity after temperature circulation [43].

The limitation of this study is the use of microleakage a two-dimensional measurement, and these results are most likely materials specific. Further study covering both cariologic and periodontal aspects, and clinical durability of PBE as a two-step restoration technique with larger sample size are clearly warranted.

Conclusion

In conclusion, our study would suggest that premolars with gross lesions should be subsequently restored with full covering (CAD/CAM) ceramic restorations, while PBE seems to increase fracture resistance of ceramic endocrowns, and is able to decrease marginal microleakage of restorations showing gingival walls below the CEJ.

References

  1. 1. Sorrentino R, Salameh Z, Zarone F, Tay FR, Ferrari M. Effect of post-retained composite restoration of MOD preparations on the fracture resistance of endodontically treated teeth. J Adhes Dent. 2007; 9: 49–56. pmid:17432401
  2. 2. Lin CL, Chang YH, Chang CY, Pai CA, Huang SF. Finite element and Weibull analyses to estimate failure risks in the ceramic endocrown and classical crown for endodontically treated maxillary premolar. Eur J Oral Sci. 2010; 118: 87–93. pmid:20156270
  3. 3. Eraslan O, Eraslan O, Eskitascioglu G, Belli S. Conservative restoration of severely damaged endodontically treated premolar teeth: a FEM study. Clin Oral Investig. 2011; 15: 403–408. pmid:20238232
  4. 4. Jiang W, Bo H, Yongchun G, LongXing N. Stress distribution in molars restored with inlays or onlays with or without endodontic treatment: a three-dimensional finite element analysis. J Prosthet Dent. 2010; 103: 6–12. pmid:20105674
  5. 5. Cheung W. A review of the management of endodontically treated teeth. Post, core and the final restoration. J Am Dent Assoc. 2005; 136: 611–619. pmid:15966648
  6. 6. Krejci I, Duc O, Dietschi D, de Campos E. Marginal adaptation, retention and fracture resistance of adhesive composite restorations on devital teeth with and without posts. Oper Dent. 2003; 28: 127–135. pmid:12670067
  7. 7. Sterzenbach G, Karajouli G, Naumann M, Peroz I, Bitter K. Fiber post placement with core build-up materials or resin cements-an evaluation of different adhesive approaches. Acta Odontol Scand. 2012; 70(5): 368–376. pmid:21815838
  8. 8. Bitter K, Noetzel J, Stamm O, Vaudt J, Meyer-Lueckel H, Neumann K, et al. Randomized clinical trial comparing the effects of post placement on failure rate of postendodontic restorations: preliminary results of a mean period of 32 months. J Endod. 2009; 35(11): 1477–1482. pmid:19840634
  9. 9. Frankenberger R, Hehn J, Hajto J, Kramer N, Naumann M, Koch A, et al. Effect of proximal box elevation with resin composite on marginal quality of ceramic inlays in vitro. Clin Oral Investig. 2013; 17: 177–183. pmid:22358378
  10. 10. Kielbassa AM, Philipp F. Restoring proximal cavities of molars using the proximal box elevation technique: Systematic review and report of a case. Quintessence Int. 2015; 46(9): 751–764. pmid:26159213
  11. 11. Schmidt JC, Sahrmann P, Weiger R, Schmidlin PR, Walter C. Biologic width dimensions—a systematic review. J Clin Periodontol. 2013; 40: 493–504. pmid:23461747
  12. 12. Dietschi D, Spreafico R. Current clinical concepts for adhesive cementation of tooth-colored posterior restorations. Pract Periodontics Aesthet Dent. 1998; 10: 47–54; quiz 56. pmid:9582662
  13. 13. Bresser RA, Gerdolle DI, van den Heijkant A, Sluiter-Pouwels LM. A, Cune MS, Gresnigt MMM. Up to 12 years clinical evaluation of 197 partial indirect restorations with deep margin elevation in the posterior region. J Dent. 2019; 91:103227. pmid:31697971
  14. 14. Suryakumari NB, Reddy PS, Surender LR, Kiran R. In vitro evaluation of influence of salivary contamination on the dentin bond strength of one-bottle adhesive systems. Contemp Clin Dent. 2011; 2(3): 160–164. pmid:22090757
  15. 15. Tachibana A, Castanho GM, Vieira SN, Matos AB. Influence of blood contamination on bond strength of a self-etching adhesive to dental tissues. J Adhes Dent. 2011; 13: 349–358. pmid:20978637
  16. 16. Dietschi D, Olsburgh S, Krejci I, Davidson C. In vitro evaluation of marginal and internal adaptation after occlusal stressing of indirect class ii composite restorations with different resinous bases. Eur J Oral Sci. 2003; 111(1): 73–80. pmid:12558811
  17. 17. Borges AL, Borges AB, Xavier TA, Bottino MC, Platt JA. Impact of quantity of resin, c-factor, and geometry on resin composite polymerization shrinkage stress in class v restorations. Oper Dent. 2014; 39(2): 144. pmid:23786611
  18. 18. Shibasaki S, Takamizawa T, Nojiri K, Imai A, Tsujimoto A, Endo H, et al. Polymerization behavior and mechanical properties of high-viscosity bulk fill and low shrinkage resin composites. Oper Dent. 2017; 42(6): E177–E187. pmid:28976846
  19. 19. Ferracane JL. Buonocore Lecture. Placing dental composites-a stressful experience. Oper Dent. 2008; 33: 247–257. pmid:18505214
  20. 20. Park J, Chang J, Ferracane J, Lee IB. How should composite be layered to reduce shrinkage stress: incremental or bulk filling? Dent Mater. 2008; 24: 1501–1505. pmid:18433857
  21. 21. Bagis YH, Baltacioglu IH, Kahyaogullari S. Comparing microleakage and the layering methods of silorane-based resin composite in wide Class II MOD cavities. Oper Dent. 2009; 34: 578–585. pmid:19830973
  22. 22. El-Damanhoury HM, Haj-Ali RN, Platt JA. Fracture resistance and microleakage of endocrowns utilizing three CAD-CAM blocks. Oper Dent. 2015; 40(2): 201–210. pmid:25268039
  23. 23. Furuse AY, Gordon K, Rodrigues FP, Silikas N, Watts DC. Colour-stability and gloss-retention of silorane and dimethacrylate composites with accelerated aging. J Dent. 2008; 36: 945–952. pmid:18778884
  24. 24. Ghajghouj O, Taşar-Faruk S. Evaluation of Fracture Resistance and Microleakage of Endocrowns with Different Intracoronal Depths and Restorative Materials Luted with Various Resin Cements. Materials (Basel). 2019; 12(16): 2528. pmid:31398883
  25. 25. Yeolekar TS, Chowdhary NR, Mukunda KS, Kiran NK. Evaluation of Microleakage and Marginal Ridge Fracture Resistance of Primary Molars Restored with Three Restorative Materials: A Comparative in vitro Study. Int J Clin Pediatr Dent. 2015; 8(2): 108–113. pmid:26379377
  26. 26. Lambrechts P, Debels E, Van Landuyt K, Peumans M, Van Meerbeek B. How to simulate wear? Overview of existing methods. Dent Mater. 2006; 22: 693–701. pmid:16712913
  27. 27. Wahab FK, Shaini FJ, Morgano SM. The effect of thermocycling on microleakage of several commercially available composite Class V restorations in vitro. J Prosthet Dent. 2003; 90: 168–174. pmid:12886210
  28. 28. Chuang SF, Jin YT, Liu JK, Chang CH, Shieh DB. Influence of flowable composite lining thickness on Class II composite restorations. Oper Dent. 2004; 29: 301–308. pmid:15195731
  29. 29. Soh MS, Yap AU, Siow KS. The effectiveness of cure of LED and halogen curing lights at varying cavity depths. Oper Dent. 2003; 28: 707–715. pmid:14653284
  30. 30. Dartora NR, Ferreira MBDC, Spazzin AO, Sousa Neto MD, Dartora G, Gomes EA. Effect of Intracoronal Depth of Teeth Restored with Endocrowns on Fracture Resistance: In Vitro and 3-dimensional Finite Element Analysis. J Endod. 2018; 44(7): 1179–1185. pmid:29866407
  31. 31. Pedrollo Lise D, Van Ende A, De Munck J, Umeda Suzuki TY, Cardoso Vieira LC, Van Meerbeek B. Biomechanical behavior of endodontically treated premolars using different preparation designs and CAD/CAM materials. J Dent. 2017; 59: 54–61. pmid:28214537
  32. 32. Firouzmandi M, Doozandeh M, Jowkar Z, Abbasi S. Effect of composite/amalgam thickness on fracture resistance of maxillary premolar teeth, restored with combined amalgam-composite restorations. J Clin Exp Dent. 2016; 8(3): e268–e272. pmid:27398176
  33. 33. de Assis FS, Lima SN, Tonetto MR, Bhandi SH, Pinto SC, Malaquias P, et al. Evaluation of Bond Strength, Marginal Integrity, and Fracture Strength of Bulk- vs Incrementally-filled Restorations. J Adhes Dent. 2016; 18: 317–323. pmid:27419244
  34. 34. Ilgenstein I, Zitzmann NU, Buhler J, Wegehaupt FJ, Attin T, Weiger R, et al. Influence of proximal box elevation on the marginal quality and fracture behavior of root-filled molars restored with CAD/CAM ceramic or composite onlays. Clin Oral Investig. 2015; 19: 1021–1028. pmid:25248949
  35. 35. Camacho GB, Goncalves M, Nonaka T, Osorio AB. Fracture strength of restored premolars. Am J Dent. 2007; 20: 121–124. pmid:17542207
  36. 36. Mincik J, Urban D, Timkova S, Urban R. Fracture resistance of endodontically treated maxillary premolars restored by various direct filling materials: an in vitro study. Int J Biomater. 2016; 2016(4): 1–5. pmid:27656212
  37. 37. Ameri H, Ghavamnasiri M, Abdoli E. Effects of load cycling on the microleakage of beveled and nonbeveled margins in class v resin-based composite restorations. J Contemp Dent Pract. 2010. 11(5): 25–32. pmid:20978721
  38. 38. Litonjua LA, Andreana S, Bush PJ, Tobias TS, Cohen RE. Noncarious cervical lesions and abfractions. J Am Dent Assoc. 2003; 134: 845–850. pmid:12892441
  39. 39. Agarwal RS, Hiremath H, Agarwal J, Garg A. Evaluation of cervical marginal and internal adaptation using newer bulk fill composites: An in vitro study. J Conserv Dent. 2015; 18: 56–61. pmid:25657529
  40. 40. Francis AV, Braxton AD, Ahmad W, Tantbirojn D, Simon JF, Versluis A. Cuspal Flexure and Extent of Cure of a Bulk-fill Flowable Base Composite. Oper Dent. 2015; 40: 515–523. pmid:25741908
  41. 41. Moorthy A, Hogg CH, Dowling AH, Grufferty BF, Benetti AR, Fleming GJ. Cuspal deflection and microleakage in premolar teeth restored with bulk-fill flowable resin-based composite base materials. J Dent. 2012; 40: 500–505. pmid:22390980
  42. 42. Jawaed NUA, Ali SAY, Qazi FUR, Ahmed S. An Evaluation of Microleakage at the Cervical Margin Between two Different Class II Restorative Techniques Using Dye Penetration Method. J Coll Physicians Surg Pak. 2016; 26 (9): 748–752. pmid:27671178
  43. 43. Sarfati A, Tirlet G. Deep margin elevation versus crown lengthening: biologic width revisited. Int J Esthet Dent. 2018; 13(3): 334–356. pmid:30073217