Influence of head and neck position on the performance of supraglottic airway devices: A systematic review and meta-analysis

  • Min-Soo Kim ,

    Contributed equally to this work with: Min-Soo Kim, Jin Ha Park

    Roles Data curation, Formal analysis, Investigation, Methodology, Writing – original draft, Writing – review & editing

    Affiliation Department of Anesthesiology and Pain Medicine, Severance Hospital and Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea

  • Jin Ha Park ,

    Contributed equally to this work with: Min-Soo Kim, Jin Ha Park

    Roles Data curation, Investigation, Methodology, Writing – original draft, Writing – review & editing

    Affiliation Department of Anesthesiology and Pain Medicine, Severance Hospital and Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea

  • Ki-Young Lee,

    Roles Data curation, Investigation, Writing – review & editing

    Affiliation Department of Anesthesiology and Pain Medicine, Severance Hospital and Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea

  • Seung Ho Choi,

    Roles Data curation, Investigation, Writing – original draft, Writing – review & editing

    Affiliation Department of Anesthesiology and Pain Medicine, Severance Hospital and Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea

  • Hwan Ho Jung,

    Roles Data curation, Investigation, Writing – review & editing

    Affiliation Department of Anesthesiology and Pain Medicine, National Health Insurance Service Ilsan Hospital, Goyang City, Gyeonggi-do, Republic of Korea

  • Ji-Ho Kim,

    Roles Data curation, Investigation, Writing – review & editing

    Affiliation Department of Anesthesiology and Pain Medicine, National Health Insurance Service Ilsan Hospital, Goyang City, Gyeonggi-do, Republic of Korea

  • Bora Lee

    Roles Conceptualization, Data curation, Formal analysis, Methodology, Supervision, Validation, Writing – original draft, Writing – review & editing

    dreamkaist@yuhs.ac

    Affiliation Department of Anesthesiology and Pain Medicine, Severance Hospital and Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea

Abstract

Background

Changes in head and neck position may significantly affect the performance of supraglottic airway devices (SADs) by altering the pharyngeal structure.

Purpose

This systematic review and meta-analysis aimed to elucidate the effect of changes in head and neck position on performance of SADs.

Data source

Bibliographic databases, including PubMed, EMBASE, the Cochrane library, and the Web of Science.

Study eligibility criteria

Prospective studies investigating the effects of head and neck positions on the performance of SADs.

Methods

A random effect model was applied in the all analyses. Subgroup analysis was performed according to the type of device and the age of patient. The oropharyngeal leak pressure was the primary outcome measure. Secondary outcome measures included peak inspiratory pressure, fibreoptic view, and ventilation score (PROSPERO, CRD42017076971).

Results

Seventeen studies met the eligibility criteria. Overall, the oropharyngeal leak pressure significantly increased (mean difference 4.07 cmH2O; 95% confidence interval 3.30 to 4.84) during neck flexion with adverse effects on ventilation and fibreoptic view. Conversely, the oropharyngeal leak pressure decreased (mean difference 4.05; 95% confidence interval 4.90 to 3.20) during neck extension with no significant effect on ventilation or fibreoptic view. Rotation of the head and neck did not significantly affect SAD performance.

Conclusions

The reduced oropharyngeal leak pressure in the extended neck position was not associated with impaired ventilation except with the air-Q self-pressurizing airway. The flexed neck position significantly worsens ventilation and the alignment between the SAD and glottis despite improving the seal except with the air-Q self-pressurizing airway and LMA Proseal.

Introduction

Supraglottic airway devices (SADs) are frequently used in lieu of tracheal intubation for patients undergoing elective procedures under general anesthesia.[15] Compared with tracheal intubation, the use of SADs has been shown to reduce the incidence of postoperative pharyngolaryngeal complications and shorten recovery time from anesthesia.[4] Despite these advantages, the performance of SADs can be affected by head and neck position.[5,6]

The volume and shape of the pharyngeal space changes significantly with changes in head and neck position.[4,5,7] The flexed neck position reduces the pharyngeal anteroposterior diameter by eliminating the longitudinal tension in the anterior pharyngeal muscles. Conversely, the extended neck position increases the anteroposterior diameter of the pharynx by elevating the laryngeal inlet.[4,8] Because the pharyngeal anatomy changes according to the head and neck position, the performance of SADs may be affected, including the sealing function, ventilation, and fibreoptic view.[4,912]

Since the laryngeal mask airway (LMA) Classic was first introduced, several other types of SADs have been developed and utilised in clinical practice.[1,4,9,13,14] Although the design of most SADs is generally based on the LMA Classic, each device has its own unique structural characteristics.[4,8,12,15] In addition, newer SADs, such as the i-gel and the air-Q self-pressurizing airway, do not require cuff inflation.[4,14]

Several studies have reported changes in SAD performance according to head and neck position but with conflicting results.[4,12,16,17] Therefore, this systematic review and meta-analysis aimed to integrate the existing data to elucidate the effect of head and neck position on the overall performance of SADs, as well as the performance of individual devices.

Materials and methods

This systematic review and meta-analysis was reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines.[18] The protocol was registered with the International Prospective Registry of Systematic Reviews (PROSPERO, CRD42017076971) on September 14, 2017.

Eligibility criteria

The studies included in the meta-analysis were prospective trials, including those with a crossover design, which investigated the influence of the various head and neck positions on the performance of SADs. The participants of studies included in this review were pediatric and adult patients who underwent general anesthesia with an SAD for airway management. The comparator was neutral head and neck position and intervention was changes of head and neck position, including flexion, extension, and rotation. The primary outcome measure was the oropharyngeal leak pressure. Secondary outcome measures were peak inspiratory pressure, fibreoptic view grade, and ventilation score. We included the studies which have the primary outcome.

Literature search

We performed a computerised, systematic search of PubMed, EMBASE, the Cochrane library, and the Web of Science on October 17, 2017, using combinations of the following search terms: head, neck, position, positions, extension, rotation, flexion, supraglottic airway, laryngeal mask, i-gel, air-Q, and laryngeal tube. The search strategy created for use in PubMed was ((((((((((head) OR neck)) AND ((positions) OR position))) OR extension) OR rotation) OR flexion)) AND (((((supraglottic airway) OR laryngeal mask) OR i-gel) OR air-Q) OR laryngeal tube)). No age or language restrictions were applied to article selection. Published data that did not belong to general journal articles, such as letters, editorials, and conference papers, were excluded. Search results derived from each database were integrated and duplicates were eliminated. Two authors (K.-Y.L., S.H.C.) independently performed a primary screening of the search results based on article titles and abstracts. The same authors then conducted a full-text assessment of articles for final inclusion. Disagreements regarding study inclusion were resolved by discussion and consensus, and uncertainties were resolved by consulting a third author (J.-H. K.). In addition, the reference lists of all included articles were investigated to find other potentially eligible studies.

Risk of bias assessment

Two authors (B.L. and H.H.J.) independently assessed the quality of the included studies using the Cochrane Collaboration Risk of Bias Tool, which evaluates several domains of bias, including selection, performance, detection, attrition, reporting, and other forms of bias.[19] Each bias domain was graded as high risk, low risk, or unclear. Disagreements regarding bias were resolved through discussion and consensus, and uncertainties were resolved by consulting a third author (J.H.P.).

Data collection

Two authors (J.H.P. and M.-S.K.) independently collected relevant data from the final selected studies. Disagreements regarding data collection were resolved by discussion and consensus, and uncertainties were resolved by consulting a third author (B.L.). The authors extracted the following data: the primary author’s name, publication year, study design, sample size, patient characteristics, type of SAD, details of interventions, primary and secondary outcome measures, conflict of interests, and funding source. In addition, we emailed the study authors to request for raw data in order to compute missing values and correlation coefficients. The ventilation quality scores were reversed for comparisons with the ventilation scores.

When the data were described as median, total range, and interquartile range (IQR), the mean value and standard deviations were estimated using formulae developed by Wan and colleagues.[20] If the value was provided as 95% confidence intervals, the standard deviations were calculated inversely using the confidence interval formula with t-distribution.

Statistical analysis

Data were analysed using R version 3.4.1 (R Foundation for Statistical Computing, Vienna, Austria). We calculated the individual values and pooled estimates of the raw mean difference with 95% confidence interval for continuous outcomes and the risk ratio (RR) with 95% confidence interval for dichotomous outcomes. Correlation coefficients used to compute estimates for each study were computed from the raw data provided by the study authors. If raw data were unavailable, correlation coefficients obtained from the studies with available raw data were applied. The I2 statistic was used to assess heterogeneity using the following predetermined thresholds: low heterogeneity (I2 = 25–49%), moderate heterogeneity (I2 = 50–74%), and high heterogeneity (I2 > 75%).[21] A random effect model with the DerSimonian and Laird method was applied in the all analyses. Subgroup analysis was performed according to the type of device and the age of patient. Publication bias was assessed by visually examining the asymmetry of a funnel plot and using Egger’s linear regression test.[22] The presence of publication bias was suspected when the P-value of the Egger test was less than 0.1.

Results

Of the 1004 articles retrieved from the literature search, 17 studies met the eligibility criteria, representing a total of 959 patients (Fig 1). A full description of the characteristics of the included studies is provided in Table 1.

Study characteristics

SADs used for the included studies were as follows: the air-Q self-pressurizing airway was used in 1 study,[4] the i-gel was used in 5 studies,[1012,14,23] the LMA Supreme was used in 2 studies,[6,23] the laryngeal tube was used in 1 study,[9] the laryngeal tube suction was used in 4 studies,[6,8,17,24] the LMA Proseal was used in 6 studies,[8,11,15,16,24,25] the Cobra perilaryngeal airway was used in 1 study,[8] the LMA Classic was used in 5 studies,[5,7,9,13,25] and the LMA Flexible was used in 2 studies.[7,13] The reinforced LMA was regarded as the LMA Flexible.[13] Seven studies investigated SADs in pediatric patients,[5,9,10,12,15,17,23] and 4 studies did not use neuromuscular blocking agents.[5,9,23,24] Oropharyngeal leak pressure was defined as the airway pressure at which a leak sound was detected around the patient’s mouth and at which the airway pressure had reached equilibrium, when the pressure-limiting valve of the anesthesia breathing system was closed and the fresh gas flow rate was fixed at 3 L/min.[2] Peak inspiratory pressure was measured using a respirator and was indicated on the display during mechanical ventilation.[9] Seven studies recorded data of the peak inspiratory pressure at a tidal volume of 10 mL/kg [4,1012,14,17] or 8 mL/kg.[9] Thirteen studies reported data on the fibreoptic view, wherein the Brimacombe score[26] was used in 8 studies,[4,7,8,11,1416,25] the Okuda score[5] was used in 3 studies,[5,10,12] the Cook score[1] was used in 1 study,[17] and the 5-point score was used in 1 study.[23] The best and worst fibreoptic view ratings of the devices in each study was used for this meta-analysis. One study abstained from evaluating the fiberoptic score if patients experienced ventilatory difficulty after neck motion.[8] Seven studies provided data regarding the ventilation score[4,1012,14,17] or quality.[16] The ventilation score was rated from 0 to 3 based on three criteria (no leakage at an airway pressure of 15 cmH2O, bilateral chest excursion with 20 cmH2O of peak inspiratory pressure, and a square-wave capnogram).[3] The ventilation quality was assessed with a 3-point ventilation score, wherein 1 = chest expansion without gas leakage; 2 = chest expansion with obvious gas leakage; and 3 = minimal chest expansion and considerable gas leakage.[2,16] In studies in which data were reported in both the left- and right-rotated neck positions, we selected data measured in the right-rotated position.[5,6,9,24] One study was published in German with an abstract available in English.[24] After translating the article to English, we performed data collection and bias evaluation from this included study. Raw data provided by Kim and colleagues was used to determine correlation coefficients and compute effect sizes for the oropharyngeal leak pressure and peak inspiratory pressure.[4] Effect sizes for the fibreoptic view and ventilation score were estimated as two independent groups, without applying correlation coefficients. All of the included studies were graded using the Cochrane Collaboration Risk of Bias Tool (Table 2).

thumbnail
Table 2. Assessment of bias risk items for each included study.

https://doi.org/10.1371/journal.pone.0216673.t002

Oropharyngeal leak pressure (Table 3)

Sixteen studies reported data comparing the oropharyngeal leak pressure between the flexed and neutral neck positions.[414,16,17,2325] The overall analysis showed a significantly higher oropharyngeal leak pressure in the flexed neck position than in the neutral neck position (mean difference 4.07 cmH2O; 95% confidence interval 3.30 to 4.84; I2 = 92.8%; P < 0.001) (Fig 2). Fourteen studies reported data comparing the oropharyngeal leak pressure between the extended and neutral neck positions.[411,13,14,17,2325] The overall analysis revealed that the oropharyngeal leak pressure was significantly lower in the extended neck position than in the neutral neck position (mean difference 4.05; 95% confidence interval 4.90 to 3.20; I2 = 83.0%; P < 0.001) (Fig 3). A greater reduction in the oropharyngeal leak pressure was observed during neck extension with the air-Q self-pressurizing airway (mean difference 8.60; 95% confidence interval 10.07 to 7.13),[4] the LMA Proseal (mean difference 6.31; 95% confidence interval 8.42 to 4.20),[8,11,24,25] and the LMA Flexible (mean difference 4.41; confidence interval 6.20 to 2.63).[7,13] Subgroup analysis by patient age revealed that the decrease in oropharyngeal leak pressure during neck extension was greater in adult patients (mean difference 4.64; 95% confidence interval 5.78 to 3.51)[4,68,11,13,14,24,25] than in pediatric patients (mean difference 2.80; 95% confidence interval 3.55 to 2.04).[5,9,10,17,23]

thumbnail
Fig 2. Forest plot of the oropharyngeal leak pressure in the flexed neck position compared with the neutral neck position.

https://doi.org/10.1371/journal.pone.0216673.g002

thumbnail
Fig 3. Forest plot of the oropharyngeal leak pressure in the extended neck position compared with the neutral neck position.

https://doi.org/10.1371/journal.pone.0216673.g003

Thirteen studies reported data comparing the oropharyngeal leak pressure between the rotated and neutral neck positions.[49,11,1315,17,24,25] The overall analysis showed no significant difference in the oropharyngeal leak pressure between the rotated and the neutral neck positions. In subgroup analyses, the oropharyngeal leak pressure was significantly higher in the rotated neck position with the LMA Classic (mean difference 2.17; 95% confidence interval 1.29 to 3.06; I2 = 41.4%; P < 0.001),[5,7,9,13,25] as well as in the pediatric subgroup (mean difference 1.56; 95% confidence interval 0.96 to 2.16; I2 = 0.0%; P < 0.001).[5,9,15,17]

Peak inspiratory pressure (Table 4)

thumbnail
Table 4. Meta-analysis of peak inspiratory pressure (cmH2O).

https://doi.org/10.1371/journal.pone.0216673.t004

Seven studies reported data comparing the peak inspiratory pressure between the flexed and neutral neck positions.[4,912,14,17] The overall analysis revealed a significantly higher peak inspiratory pressure in the flexed neck position than in the neutral neck position (mean difference 5.18; 95% confidence interval 3.81 to 6.55; I2 = 95.6%; P < 0.001). The increase in peak inspiratory pressure was greater in pediatric patients (mean difference 6.71; 95% confidence interval 4.80 to 8.62)[9,10,12,17] than in adult patients (mean difference 3.34; 95% 1.99 to 4.70).[4,11,14] Six studies compared the peak inspiratory pressure between the extended and neutral neck positions.[4,912,17] The overall analysis revealed a significantly lower peak inspiratory pressure in the extended neck position than in the neutral neck position (mean difference 2.23; 95% confidence interval 3.21 to 1.26; I2 = 89.6%; P < 0.001). Five studies reported data comparing the peak inspiratory pressure between the rotated and neutral neck positions.[4,9,11,14,17] Neither the overall or subgroup analyses showed any significant change in peak inspiratory pressure during neck rotation.

Fibreoptic view evaluation (Tables 5 and 6)

Twelve studies reported data comparing the fibreoptic view between the flexed and neutral neck positions.[4,5,7,8,1012,14,16,17,23,25] The overall analysis revealed that the flexed neck position significantly increased the incidence of receiving the worst fibreoptic view rating (RR 1.70; 95% confidence interval 1.06 to 2.73; I2 = 40.8%; P < 0.028)[5,7,8,1012,16,17,23,25] and decreased the incidence of receiving the best fibreoptic view rating (RR 0.76; 95% confidence interval 0.61 to 0.96; I2 = 38.9%; P = 0.020).[4,5,7,8,1012,14,17,23,25] Compared with other devices, the incidence of the worst fibreoptic view rating was significantly higher with the i-gel (RR 7.67; 95% confidence interval 1.75 to 33.70; I2 = 0.0%; P = 0.007).[1012] In pediatric patients, the flexed neck position resulted in a substantially greater chance of receiving the worst fibreoptic view rating (RR 4.59; 95% confidence interval 2.36 to 8.95; I2 = 0.0%; P < 0.001)[5,10,12,17,23] and a significantly lower chance of receiving the best fibreoptic view rating (RR 0.37; 95% confidence interval 0.18 to 0.75; I2 = 59.4%; P = 0.006).[5,10,12,17,23]

Ten studies reported data comparing the fibreoptic view between the extended and neutral neck positions.[4,5,7,8,10,11,14,17,23,25] Neck extension did not significantly change the incidence of receiving the worst fibreoptic view rating in the overall or subgroup analyses.

Nine studies reported data comparing the fibreoptic view between the rotated and neutral neck positions.[4,5,7,8,11,14,15,17,25] The analysis of these studies revealed that the rotated neck position did not significantly affect the incidence of receiving either the worst or best fibreoptic view rating.

Ventilation score (Table 7)

Seven studies reported data comparing the ventilation score between the flexed and neutral neck positions.[4,1012,14,16,17] The overall analysis revealed a significantly lower ventilation score in the flexed neck position (mean difference 0.74; 95% confidence interval 1.20 to 0.28; I2 = 98.8%; P = 0.002). Subgroup analyses according to the type of device revealed a significantly lower ventilation score with the i-gel (mean difference 1.25; 95% confidence interval 1.72 to 0.79; I2 = 91.5%; P < 0.001)[10,11,14] and the laryngeal tube suction (mean difference 1.50; 95% confidence interval 1.76 to 1.24; P < 0.001),[17] but no significant differences were found with the air-Q self-pressurizing airway[4] or the LMA Proseal.[11,16] Subgroup analysis by patient age revealed a significant decrease in the ventilation score during neck flexion in pediatric patients (mean difference 1.50; 95% confidence interval 1.63 to 1.37; I2 = 0.0%; P < 0.001), but not in adult patients.[10,12,17]

Five studies reported data comparing the ventilation score between the extended and neutral neck positions.[4,10,11,14,17] The overall analysis did not reveal any significant change in the ventilation score during neck extension (mean difference 0.11; 95% confidence interval 0.30 to 0.07; I2 = 92.3%; P = 0.221). Subgroup analysis revealed that neck extension only resulted in a significant decrease in the ventilation score with the air-Q self-pressurizing airway (mean difference 0.55; 95% confidence interval 0.69 to 0.41; P < 0.001).[4]

Four studies reported data comparing the ventilation score between the rotated and neutral neck positions.[4,11,14,17] The analysis of these studies revealed no significant change in the ventilation score between the two neck positions.

Discussion

This meta-analysis shows that the flexed neck position significantly improves airway sealing but adversely affects ventilation and the fibreoptic view with most SADs. Although neck extension significantly reduced airway sealing, it did not affect ventilation or the fibreoptic view. Overall, neck rotation did not significantly affect SAD performance.

Changes in head and neck position can alter pharyngeal volume and shape, which can significantly affect the performance of SADs.[4,6,12] It might be expected that neck flexion would enhance the sealing function of SADs because it reduces the pharyngeal anteroposterior diameter by eliminating the longitudinal tension in the anterior pharyngeal muscles.[4,9,11,27] However, the reduction in space of the laryngeal inlet that occurs in the flexed neck position may provoke airway obstruction, resulting in poor ventilation and the need for higher airway pressures.[8,17] Conversely, neck extension increases the anteroposterior diameter of the pharynx by elevating the laryngeal inlet; thus, it may lead to decreased contact between the cuff and the mucosa, reducing the oropharyngeal leak pressure.[4,8] These changes in the pharyngeal structure according to head and neck position may affect the results of the overall analysis. However, substantial heterogeneity indicates that the results of the overall analysis may be more valid than the results of the subgroup analyses. In addition, the results from some of the subgroup analyses, according to the type of device and patient age, were inconsistent with the results of the overall analysis.

According to the subgroup analyses, the oropharyngeal leak pressure did not increase during neck flexion with the laryngeal tube suction. The study reported that the laryngeal tube suction has a large ellipsoid cuff and its anteroposterior diameter is larger than that of the LMA Proseal.[8] Due to these unique structural characteristics of the laryngeal tube suction, the reduced pharyngeal space that develops in the flexed neck position may not improve airway sealing around the cuff of this device. As evidence of this hypothesis, subgroup analysis revealed that the corbra perilaryngeal airway, which has a cuff of comparable size and shape to that of the laryngeal tube suction, also showed a smaller increase in the oropharyngeal leak pressure during neck flexion (mean difference 2.40 cmH2O), compared with the results of the overall analysis (mean difference 4.07 cmH2O).[8] Another result of the laryngeal tube suction in the flexed neck position was impaired ventilatory function. In fact, the greatest reduction in the ventilation score and the largest increase in the peak inspiratory pressure between the flexed and neutral neck positions was seen with the laryngeal tube suction. The previous study revealed that impaired ventilation in the flexed neck position was observed in 7 subjects with the laryngeal tube suction, and these subjects were excluded from the oropharyngeal leak pressure assessment.[8] Considering that there was no benefit in airway sealing and that ventilation became more difficult with the laryngeal tube suction during neck flexion, clinicians may need to exercise caution when choosing this device for procedures requiring the flexed neck position.

The ventilation score of the air-Q self-pressurizing airway did not significantly change in the flexed neck position compared with the neutral neck position. However, this does not necessarily indicate that partial airway obstruction does not occur, given the higher peak inspiratory pressure, and because it was more common to see the anterior epiglottis in the fibreoptic view with the air-Q self-pressurizing airway in the flexed neck position.[4] However, the partial airway obstruction that occurred with the air-Q self-pressurizing airway in the flexed position seems to be clinically insignificant.[4] As with the air-Q self-pressurizing airway, the i-gel also has a non-inflatable cuff, and a substantial decrease in the ventilation score was observed during neck flexion with this device.[1012,14] In addition, the incidence of receiving the worst fibreoptic view rating was greatly increased as the vocal cords were not visible with the i-gel in the flexed neck position; however, this effect on the fibreoptic view was not observed with the air-Q self-pressurizing airway in the flexed neck position.[4,1012,14,23] The difference in the fibreoptic view and ventilation score between the air-Q self-pressurizing airway and the i-gel in the flexed neck position may be attributable to the i-gel’s smaller area ventilating orifice, straighter airway tube, and thicker anteroposterior diameter compared with the air-Q self-pressurizing airway.[4] Although the air-Q self-pressurizing airway exhibited satisfactory performance during neck flexion, the i-gel exhibited worse performance during neck extension. Kim and colleagues demonstrated that the oropharyngeal leak pressure significantly decreased with the air-Q self-pressurizing airway in the extended neck position.[4] The sealing function of SADs, as assessed by the oropharyngeal leak pressure, is important for protecting the larynx and ensuring adequate ventilation.[28] Brimacombe and colleagues suggested that the oropharyngeal leak pressure should be greater than 10 cmH2O, as this is the approximate fluid pressure within the posterior pharyngeal space.[29] From the raw data provided by Kim and colleagues, an oropharyngeal leak pressure of less than 10 cmH2O was observed in 39% of cases with the air-Q self-pressurizing airway in the extended neck position.[4] In addition to inadequate airway protection, the air-Q self-pressurizing airway did not provide sufficient ventilatory function in the extended neck position, as evidenced by the decrease in the expiratory tidal volume and ventilation score.[4] Conversely, the i-gel provided clinically reasonable sealing and ventilatory function in the extended neck position relative to its function in the neutral neck position. This discrepancy between the function of these two devices may stem from the difference in cuff design. The cuff of the i-gel has a large anteroposterior diameter that can fill the wider pharyngeal space in the extended neck position, whereas the self-regulated cuff of the air-Q self-pressurizing airway seems to be insufficient to fill the increased pharyngeal space.[4] In light of these results, the i-gel may be preferable to the air-Q self-pressurizing airway during procedures requiring the extended neck position.

The LMA Proseal was the most commonly assessed device in the studies included in this meta-analysis.[8,11,15,16,24,25] The subgroup analysis revealed that the decrease in the oropharyngeal leak pressure with the LMA Proseal in the extended neck position was greater than the decrease in the oropharyngeal leak pressure seen in the overall analysis. As mentioned previously, the LMA Proseal has a smaller anteroposterior diameter and different cuff design than the laryngeal tube suction and corbra perilaryngeal airway.[8] The diameter and/or shape of the LMA Proseal may be associated with its reduced sealing function during neck extension. However, Park and colleagues reported that the LMA Proseal provided a reasonable mean oropharyngeal leak pressure value [18.5 (5.4) cmH2O] in the extended neck position and did not result in ventilation difficulty despite substantial oropharyngeal leak pressure reduction (mean difference 8.00 cmH2O).[8] In addition, no deterioration in the ventilation score or fibreoptic view with changes in head and neck position were observed with the LMA Proseal in our meta-analysis. Given the current evidence, the LMA Proseal could be utilised regardless of the head and neck posture.

Subgroup analyses by patient age showed significant differences in outcomes between pediatric and adult patients. In terms of the sealing function of SADs, the extent of the oropharyngeal leak pressure increase during neck flexion was comparable between both age groups, but the decrease in oropharyngeal leak pressure in pediatric patients during neck extension was less than the decrease in oropharyngeal leak pressure seen in adult patients. In the flexed neck position, the peak inspiratory pressure increased more than twice as much in pediatric patients as it did in adult patients, and the fibreoptic view and ventilation score greatly deteriorated in pediatric patients. This discrepancy according to patient age may be attributable to the anatomical differences in the upper airway between children and adults. Compared with adult patients, children have a larger tongue and epiglottis and more frequently have enlarged tonsils, which may result in a narrower pharyngeal space.[30] These anatomical features in pediatric patients seemed to worsen the negative effect of neck flexion on ventilation and alleviate the negative effect of neck extension on SAD sealing function. Therefore, neck extension may improve the fibreoptic view when using an SAD as a conduit for tracheal intubation in pediatric patients.

This meta-analysis has several limitations. Most importantly, the results indicate moderate to high levels of heterogeneity. This heterogeneity in the overall and subgroup analyses may be due to various factors, such as the type of device, patient age, study design, and use of neuromuscular blocking agents. To alleviate this limitation, we performed subgroup analysis according to the type of device and patient age. No subgroup analyse was performed separately by using of neuromuscular blocking agents because most of the studies that did not use muscular blocking agents were conducted in children. Second, the possibility of publication bias was observed in some of the overall and subgroup analyses. Thus, the outcomes of our meta-analysis may change with the addition of newly published articles and ongoing studies. Third, the number of articles included in the overall analysis was relatively small in terms of ventilation score data and subgroup analyses with the air-Q self-pressurizing airway and corbra perilaryngeal airway.[4,8] One study used ventilation quality scores,[1] and these scores were reversed for comparisons with the ventilation scores of other studies. Although the two methods are different, higher scores indicate better ventilation in both methods. Despite these weaknesses, to the best of our knowledge, the present study represents the first meta-analysis reporting changes in the performance of SADs in various head and neck positions.

This meta-analysis demonstrates that the reduced oropharyngeal leak pressure during neck extension does not result in a clinically significant impact on ventilation except with the air-Q self-pressurizing airway. Neck flexion negatively affects ventilation and the alignment between the SAD and glottis despite improving the sealing function of the SAD except with the air-Q self-pressurizing airway and LMA Proseal.

Supporting information

S2 File. Extracted data about the oropharyngeal leak pressure according to the flexed and neutral neck position.

https://doi.org/10.1371/journal.pone.0216673.s002

(CSV)

S3 File. Extracted data about the oropharyngeal leak pressure according to the extended and neutral neck position.

https://doi.org/10.1371/journal.pone.0216673.s003

(CSV)

S4 File. Extracted data about the oropharyngeal leak pressure according to the rotated and neutral neck position.

https://doi.org/10.1371/journal.pone.0216673.s004

(CSV)

Acknowledgments

We are very grateful to the researchers who provided their raw data after our request.

References

  1. 1. Cook TM, Cranshaw J. Randomized crossover comparison of ProSeal Laryngeal Mask Airway with Laryngeal Tube Sonda during anaesthesia with controlled ventilation. Br J Anaesth. 2005;95: 261–266. pmid:15923264
  2. 2. Keller C, Brimacombe JR, Keller K, Morris R. Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients. Br J Anaesth. 1999;82: 286–287 pmid:10365012
  3. 3. Kim JT, Jeon SY, Kim CS, Kim SD, Kim HS. Alternative method for predicting optimal insertion depth of the laryngeal tube in children. Br J Anaesth. 2007;99: 704–707. pmid:17724391
  4. 4. Kim HJ, Lee K, Bai S, Kim MH, Oh E, Yoo YC. Influence of head and neck position on ventilation using the air-Q (R) SP airway in anaesthetized paralysed patients: a prospective randomized crossover study. Br J Anaesth. 2017;118: 452–457. WOS:000395339900026 pmid:28203730
  5. 5. Okuda K, Inagawa G, Miwa T, Hiroki K. Influence of head and neck position on cuff position and oropharyngeal sealing pressure with the laryngeal mask airway in children. Br J Anaesth. 2001;86: 122–124 pmid:11575387
  6. 6. Somri M, Vaida S, Fornari GG, Mendoza GR, Charco-Mora P, Hawash N, et al. A randomized prospective controlled trial comparing the laryngeal tube suction disposable and the supreme laryngeal mask airway: the influence of head and neck position on oropharyngeal seal pressure. BMC Anesthesiol. 2016;16. WOS:000385049100003 pmid:27716165
  7. 7. Keller C, Brimacombe J. The influence of head and neck position on oropharyngeal leak pressure and cuff position with the flexible and the standard laryngeal mask airway. Anesth Analg. 1999;88: 913–916 pmid:10195547
  8. 8. Park SH, Han SH, Do SH, Kim JW, Kim JH. The influence of head and neck position on the oropharyngeal leak pressure and cuff position of three supraglottic airway devices. Anesth Analg. 2009;108: 112–117. pmid:19095838
  9. 9. Biedler A, Wrobel M, Schneider S, Soltesz S, Ziegeler S, Grundmann U. Randomized evaluation of the size 2 laryngeal tube and classical laryngeal mask airway in different head and neck positions in children under positive pressure ventilation. J Anesth. 2013;27: 657–662. pmid:23460409
  10. 10. Jain D, Ghai B, Bala I, Gandhi K, Banerjee G. Evaluation of I-gel airway in different head and neck positions in anesthetized paralyzed children. Paediatr Anaesth. 2015;25: 1248–1253. WOS:000363806300009 pmid:26383088
  11. 11. Mishra SK, Nawaz M, Satyapraksh MVS, Parida S, Bidkar PU, Hemavathy B, et al. Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the ProSeal Laryngeal Mask Airway and the I-Gel: A Randomized Clinical Trial. Anesthesiol Res Pract. 2015. WOS:000363339900001 pmid:25648620
  12. 12. Jain D, Ghai B, Gandhi K, Banerjee G, Bala I, Samujh R. Evaluation of I-Gel™ size 2 airway in different degrees of neck flexion in anesthetized children–a prospective, self-controlled trial. Paediatr Anaesth. 2016;26: 1136–1141. pmid:27779349
  13. 13. Buckham M, Brooker M, Brimacombe J, Keller C. A comparison of the reinforced and standard laryngeal mask airway: ease of insertion and the influence of head and neck position on oropharyngeal leak pressure and intracuff pressure. Anaesth Intensive Care. 1999;27: 628–631 pmid:10631418
  14. 14. Sanuki T, Uda R, Sugioka S, Daigo E, Son H, Akatsuka M, et al. The influence of head and neck position on ventilation with the i-gel airway in paralysed, anaesthetised patients. Eur J Anaesthesiol. 2011;28: 597–599. pmid:21505345
  15. 15. Choi WJ, Kim YH. The influence of head rotation on ProSeal™ laryngeal mask airway sealing during paediatric myringotomy. Anaesth Intensive Care. 2007;35: 957–960 pmid:18084990
  16. 16. Xue FS, Mao P, Liu HP, Yang QY, Li CW, He N, et al. The effects of head flexion on airway seal, quality of ventilation and orogastric tube placement using the ProSeal (TM) laryngeal mask airway. Anaesthesia. 2008;63: 979–985. WOS:000258255400011 pmid:18699873
  17. 17. Kim JT, Na HS, Bae JY, Kim HJ, Shin HY, Kim HS, et al. Flexion compromises ventilation with the laryngeal tube suction II in children. Paediatr Anaesth. 2009;19: 153–158. pmid:19143960
  18. 18. Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6: e1000097. pmid:19621072
  19. 19. Higgins JP, Altman DG, Gotzsche PC, Juni P, Moher D, Oxman AD, et al. The Cochrane Collaboration's tool for assessing risk of bias in randomised trials. Bmj. 2011;343: d5928. pmid:22008217
  20. 20. Wan X, Wang W, Liu J, Tong T. Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range. BMC Med Res Methodol. 2014;14: 135. pmid:25524443
  21. 21. Higgins JP, Thompson SG. Quantifying heterogeneity in a meta-analysis. Stat Med. 2002;21: 1539–1558. pmid:12111919
  22. 22. Egger M, Davey Smith G, Schneider M, Minder C. Bias in meta-analysis detected by a simple, graphical test. Bmj. 1997;315: 629–634 pmid:9310563
  23. 23. Gupta S, Dogra N, Chauhan K. Comparison of i-gel and Laryngeal Mask Airway Supreme in Different Head and Neck Positions in Spontaneously Breathing Pediatric Population. Anesth Essays Res. 2017;11: 647–650. pmid:28928564
  24. 24. Mann V, Mann S, Rupp D, Rohrig R, Weigand M, Muller M. Influence of head position and neuromuscular block on the clinical efficacy of supraglottic airway devices. A prospective randomized study to compare the laryngeal tube suction (LTS) with the proseal laryngeal mask. [German]. Notfall Rettungsmed; 2012. pp. 136–141.
  25. 25. Brimacombe J, Keller C. Stability of the LMA-Proseal® and standard laryngeal mask airway in different head and neck positions: A randomized crossover study. Eur J Anaesthesiol. 2003;20: 65–69. pmid:12553391
  26. 26. Brimacombe J, Berry A. A proposed fiber-optic scoring system to standardize the assessment of laryngeal mask airway position. Anesth Analg. 1993;76: 457 pmid:8424538
  27. 27. Nandi PR, Charlesworth CH, Taylor SJ, Nunn JF, Dore CJ. Effect of general anaesthesia on the pharynx. Br J Anaesth. 1991;66: 157–162 pmid:1817614
  28. 28. Kim MS, Lee JH, Han SW, Im YJ, Kang HJ, Lee JR. A randomized comparison of the i-gel() with the self-pressurized air-Q() intubating laryngeal airway in children. Paediatr Anaesth. 2015;25: 405–412. pmid:25559870
  29. 29. Brimacombe J, Berry A, Brain AI. Optimal intracuff pressures with the laryngeal mask. Br J Anaesth. 1996;77: 295–296 pmid:8881646
  30. 30. Ghai B, Wig J. Comparison of different techniques of laryngeal mask placement in children. Curr Opin Anaesthesiol. 2009;22: 400–404 pmid:19434792