Figures
Abstract
Dental implants are important tools for restoring the loss of teeth. The rapid growth and periodic regeneration of antlers make Sika deer a good and less invasive alternative model for studying bone remodelling in mammals. We developed a special loading device for antlers and analysed the bone reaction around unloaded implants and under immediate loading conditions until osseointegration occurred. In micro-computed tomography images, the density of antler tissue around the implants increased as the loading time increased. This finding was histologically confirmed by the good osseointegration observed in unloaded and loaded specimens. Antler tissue displays a similar healing process to human bone. The use of an antler model is a promising alternative for implant studies that does not require animal sacrifice.
Citation: He Y, Fischer D, Hasan I, Götz W, Keilig L, Ziegler L, et al. (2018) Sika deer antler as a novel model to investigate dental implant healing: A pilot experimental study. PLoS ONE 13(7): e0200957. https://doi.org/10.1371/journal.pone.0200957
Editor: Jo-Ann L. Stanton, University of Otago, NEW ZEALAND
Received: February 28, 2018; Accepted: July 4, 2018; Published: July 31, 2018
Copyright: © 2018 He et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the paper and its Supporting Information files.
Funding: Following funding were involved in this study: Friadent GmbH (Mannheim, Germany) by sponsoring the implants for the initial investigations to improve the loading device. Straumann GmbH (Freiburg, Germany) by sponsoring the implants for the investigations in deer antlers. National Natural Science Foundation of China (11702231) by financial supporting for Mrs. Yun He. The funders did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.
Competing interests: The authors declare the following interests: Materiel support in the form of implants for the investigations in deer antlers was provided by the commercial company Straumann GmbH (Freiburg, Germany). Material support in the form of implants for the initial investigations to improve the loading device was provided by the commercial company Friadent GmbH (Mannheim, Germany). There are no patents, products in development, or marketed products to declare. This does not alter the authors’ adherence to all PLOS ONE policies on sharing data and materials.
Introduction
Dental implants are important tools for restoring the loss of single teeth and fixing tooth implant-supported fixed partial dentures after accidents, disease or age-related loss of teeth [1]. Therefore, dental implants improve the quality of a patient’s life by improving aesthetics and phonetics and by decreasing bone resorption processes in the alveolar ridge. In particular, immediately loaded dental implants offer fast dental restoration and pain relief [1,2]. Research regarding complex bone remodelling processes occurring around dental implants is crucial to improve the function and acceptance of dental implants. Therefore, in vivo models are required, and animal trials have previously been conducted in pigs and dogs that were ultimately sacrificed [3,4]. This limitation restricted an intensive investigation of bone tissue due to ethical reasons.
Deer antlers represent well-exposed and rapidly growing bones that change and regenerate periodically. Thus, antlers may be used as a good model for studying bone remodelling in mammals [5–10]. Antlers start to grow from bony pedicles located on the head of male Sika deer in winter or spring and are enveloped in vascularised velvet, the periosteum, during growth [11]. The growth rate may reach up to 1.2 cm per day during the 70 days of the fastest growth period [11]. In summer, growth ceases, and the antlers are completely mineralised; in addition, the velvet is shed, thereby exposing the bare bone of the so-called hard antlers from July to August [11,12]. The development of an abscission layer across the base induces casting of the antlers to complete the cycle and to enable subsequent regrowth [13–16].
In our study, we used Sika deer antlers as a less invasive model to analyse the bone remodelling processes occurring around dental implants in different periods until complete osseointegration of the implants was achieved, and the antlers were shed. The use of a self-developed autonomous loading device [17] enabled an in vivo analysis under an immediate loading situation without sacrificing the animals or altering the normal behaviour of the deer. Micro-computed tomography (μCT) and histological analyses were used to reveal changes in bone structure and density during healing and to understand the general ossification process and the specific reaction of bone around implants. Finite element analyses were used to observe the biomechanical properties of the implant and the surrounding antler tissue.
Materials and methods
Animal selection
Six healthy 4-year-old male captive bred and tamed Sika deer (Cervus nippon) were utilised in this study. The median weight of the animals was 64 kg (all 50–70 kg). All animals were handled according to the policies and principles established by the German Animal Welfare Act and approved by the North Rhine-Westphalia State Agency for Nature, Environment and Consumer Protection as the competent authority (Permission No.: LANUV NRW, 84–02.04.2014.A462).
Animal preparation and the surgical procedure
The animals were intramuscularly anaesthetised with 1.2–1.5 ml of Hellabrunn Mixture (100 mg of Ketamine and 125 mg of Xylazine per ml) [18] via distance immobilisation using a carbon dioxide injection gun (DAN-INJECT JM Standard injection rifle, DAN-INJECT Smith GmbH, Walsrode, Germany) [19]. After placing the deer on a surgical table in right lateral recumbency, anaesthesia was monitored by a visual inspection of breathing, auscultation of the heart and lungs, continuous monitoring of the rectal temperature and pulse oximetry (LifeVet P, Eickemeyer Medizintechnik für Tierärzte KG, Tuttlingen, Germany). A continuous oxygen supply was ensured by the use of a nasal tube and a flow rate between 1 and 5 l/min, depending on the breathing and oxygen parameters. A continuous intravenous drip infusion was applied via the lateral saphenous vein. The non-steroidal, anti-inflammatory agent meloxicam (Meloxidyl 20 mg/ml ad us vet., Ceva Tiergesundheit, Düsseldorf, Germany) was injected intramuscularly. In addition, local analgesia was applied by injecting 3–5 ml of lidocaine beneath branches of the zygomatic nerve at the antler’s base (Lidocaine 2%, B. Braun Melsungen, Melsungen, Germany, [20, 21].
Before surgically raising the velvet from two 1.5 × 1.5-cm2-sized areas close to branches of the antler, disinfection was repeated with 70% alcohol and a 1% iodine tincture (Applichen GmbH, Darmstadt, Germany), and a longitudinal incision of 5 cm was then performed without releasing cuts to raise the velvet of both sides up to a 1-cm distance to the longitudinal incision. The implant sites were prepared by sequential drilling with a Ø 2.2-mm and a Ø 2.8-mm cylindrical twist drill and 800 U/min under sterile saline irrigation according to the manufacturer’s protocol. In five animals (deer no. 1–5), two Straumann-Standard Plus Roxolid® soft tissue level implants (Institut Straumann AG, Basel, Switzerland) with a length of 10 mm and a diameter of 3.3 mm were inserted without thread-cutting in the left antler of each deer. The distance between the two implants was 2.5 cm. Roxolid® is a titanium-zirconium alloy composed of approximately 15% zirconium and approximately 85% titanium and has been specifically designed for use in dental implantology [22]. The first implant received a ball abutment for transvelvet healing, and the second received a closure screw. The tissues collected from the antlers of the sixth animal (deer no. 6, control animal that did not receive an implant) using a trepan drill were used as a control. The velvet was finally sutured using Serafit 4/0 (SERAG-WIESSNER GmbH & Co. KG, Naila, Germany) and was subsequently covered with a Hansaplast spray bandage (Beiersdorf AG, Hamburg, Germany). The first implant was immediately vertically loaded via the custom-made loading device fixed with bone screws [17], whereas the second implant remained unloaded (Fig 1). The self-developed load control unit was attached to the right antler. No loading device was placed in the control animal.
Insertion of a dental implant into the Sika deer antler (left). Each animal (deer no. 1–5) received two implants at a position near the branching point of the antler. One of the implants was loaded by an autonomous loading device controlled by a micro-computer. The implant was loaded by a motor driven thrust die (yellow arrow).
Follow-up and sample removal from the deer
Post-operatively, the animals and wounds were inspected daily for the absence of wound healing complications, alterations in general health, abnormal behaviours and reduced food intake. The correct placement of the loading devices was monitored daily. Animals were assigned randomly to different time points for implant removal, ranging from 3 to 6 weeks after surgery (deer no. 2: 3 weeks post-operation; deer no. 3: 4 weeks post-operation; deer no. 4: 5 weeks post-operation; and deer no. 5: 6 weeks post-operation). For this procedure, the animals were anaesthetised as described above, and vertically loaded implants and the surrounding tissues were collected using the trepan drill. The wound cavities were rinsed thoroughly and filled with a collagen sponge for local haemostasis (KOLLAGEN resorb, RESORBA Medical GmbH, Nuremberg, Germany). Finally, the velvet was sutured, and the Hansaplast spray bandage was applied. Loading devices and the load control unit were removed. The unloaded implants were kept in place and collected after antler shedding in February of the next year to investigate the osseointegration of the implants in a fully grown antler and the structure of antler tissue in comparison to human bone. Collected samples were immediately fixed in buffered formalin (4%) and subjected to μCT scanning and subsequent analyses.
Antler density analysis
Specimens collected from antlers 3, 4, 5 and 6 weeks after implant insertion were used in this study to analyse changes in antler density at different healing periods. The specimens were scanned in a micro-computed tomography (μCT) scanner (SkyScan 1174, SkyScan Bruker-microCT, Kontich, Belgium) at 50 kV, 800 μA, and a rotation step of 0.25°. A 1-mm-thick aluminium filter was used for beam-hardening reduction. The exposure time was set to 2 s. The scan times were approximately 10 hours per sample. After scanning each sample, two calibration phantom rods (SkyScan, Kontich, Belgium) with bone mineral density (BMD) values of 0.25 and 0.75 g/cm3 calcium hydroxyapatite were scanned on the same day using the same parameters. With the scans and reconstructions of the samples and the calibration phantoms complete, the BMD calibration program was performed using a Bruker-MicroCT CT-Analyser (SkyScan, Kontich, Belgium). First, the attenuation coefficient (AC) value of the two phantoms was measured and entered in the preferences histogram calibration table. The BMD-AC formula was updated, and the calibration was completed. Second, 3 mm of peri-implant antler tissue was selected, and the BMD was automatically calculated and recorded as the mean ± standard deviation (SD).
Histological analysis
Antler samples with integrated implants were fixed in formaldehyde, dehydrated and infiltrated with ultraviolet light-activated polymethylmethacrylate (PMMA, Technovit 72100®, Heraeus Kulzer, Hanau, Germany) for one week. This procedure was followed by a 3-day immersion in a 1:1 combination of PMMA and 2-hydroxyethyl methacrylate (GMA, Heraeus Kulzer). After subsequent immersion in 100% embedding medium, the samples were photopolymerised under high-power UV light sources in three steps. Later, parallel 100- to 200-μm-thick sections were cut from the specimens using a microsaw machine (EXAKT Advanced Technologies, Norderstedt, Germany), and sections up to 20 μm in thickness were polished down using a micro grinding system (EXAKT). Sections obtained from the grinding system were stained using toluidine blue without removing the plastic medium and were evaluated under a Zeiss-Axio-Imager® light microscope (Zeiss, Jena, Germany) at original magnifications ranging between 5 and 50x.
Numerical analysis
The μCT data from the four loaded and three unloaded specimens were imported into Mimics research 19.0 and 3-Matic research 9.0 (Materialise NV, Leuven, Belgium) for 3D reconstruction. Thereafter, the models were converted into 3D finite element (FE) models using 4-noded tetrahedral elements. The final models consisted of 235,297–258,158 elements for the specimens retrieved 3, 4, 5 and 6 weeks after loading and 532,709–1,116,651 elements for the unloaded models (Fig 2). The FE analysis was performed using the software package MSC.Marc/Mentat 2010 (MSC. Software, Santa Ana, CA, USA). All materials were assumed to be homogenous, isotropic and linearly elastic. Young’s modulus of the antler tissue was calculated from the density using the following formula [23]:
FE models created 6 weeks after loading (left); and an unloaded specimen from the same antler (right).
The material properties of the implant were calculated for Roxolid® material (Young’s modulus: 98 GPa; Poisson’s ratio: 0.3; 22). A frictional contact with a frictional coefficient of 0.3 was defined between the implant and the antler tissue to simulate the immediate loading condition [24]. All models were constrained in all directions at the cutting surfaces and the bottom of the antler tissue. A linear vertical force of 10 N was applied on the implant. Stresses and strains were evaluated and compared for all of the models using the software package MSC.Marc/Mentat 2010.
Results
Animal health and behaviour after implantation and loading
Signs of infections in the antler, behavioural changes and signs of impairment in the deer were not observed during the trial. The antlers of all animals were shed regularly during the subsequent spring and were replaced with new and completely intact antlers within 2–3 months. Thus, the present trial did not disturb the normal behaviour of the deer or antler regeneration.
Number of specimens included in the analysis
For the specimens that were loaded for 2 weeks post-operatively, the thickness of the antler tissue around the implant was less than 3 mm and was not suitable for histological analysis or BMD study. For this reason, four time points were selected for removing the samples after immediate loading, namely, 3, 4, 5 and 6 weeks.
Only three unloaded implant samples were collected after antler shedding due to the difficulty finding all the shed antlers in the Sika deer’s activity space. Therefore, three unloaded specimens were included in the analysis.
Bone mineral density of antler tissue
The BMD of antler tissue around the implant increased significantly during the healing period under immediate loading conditions. The BMD values observed at 3, 4, 5 and 6 post-operative weeks were 0.31 ± 0.01 g/cm3, 0.92 ± 0.23 g/cm3, 1.54 ± 0.40 g/cm3 and 2.00 ± 0.53 g/cm3, respectively. The BMD values observed at 6 post-operative weeks were similar to those for healthy adult human cortical bone [24]. For unloaded specimens, the BMD values for antler tissue were lower than those for loaded implants. For example, in the deer segment obtained 6 weeks after implant insertion, the BMD values of antler tissue were 1.30 ± 0.11 g/cm3 around the unloaded implant and 2.00 ± 0.53 g/cm3 around the loaded implant.
Histological results
Unloaded specimens
Specimens carrying unloaded implants collected after antler shedding displayed signs of excellent osseointegration (Figs 3 and 4). The peri-implant bone was mostly compact and peri-apically more cancellous with few fat marrow spaces. Growth was also visible in the crestal direction along the machined crestal implant surfaces (Fig 3). The crestal bony plateaus were smooth, contained only a thin layer of soft tissue remnants and showed no signs of bone resorption. A close bone contact forming a tight bone-implant interface was observed along the implant surface. At higher magnifications, e.g., 40 or 50x, single osteocytes were in very close proximity (maximal 5 μm) to the implant interface (Fig 4a–4c). Short and narrow peri-implant spaces of 10–20 μm were focally observed (Fig 4d). Substantial vascularisation was observed in perforating channels and osteons near (maximal 10 μm) and distal to the implant surface. Two defects were evaluated after explantation of the implants to investigate the healing outcome. In both defects, small apically located tears, a small amount of detritus and small bony fragments were observed. A soft tissue layer with dense connective tissue covered the defect bone surfaces.
p = Peri-implant bone, asterisks = artefacts and detritus in the inside taper; toluidine blue staining, reconstruction and 5x magnification; Inset: overview of the inserted implant; 1:1.
a) High-magnification image of cortical peri-implant bone (midshaft), b) high-magnification image of periapical cancellous bone (images in both a and b were captured 3 weeks after insertion), c) high-magnification images of cortical peri-implant bone (crestal) and d) the peri-implant gap (crestal, images in both c and d were captured 6 weeks after insertion); toluidine blue staining, 10x magnification (b), 20x magnification (a, c and d); p = peri-implant bone, i = implant.
Loaded specimens
Osseointegration appeared to be insufficient in the specimens obtained at 3, 4 and 5 post-operative weeks. Peri-implant spaces with diameters up to 100 μm were observed along the implant bodies, ranging between half of the length and the entire length of the implant body. These spaces were filled with extravasations, blood cells, plaque and detritus. The peri-implant bone mostly consisted of a spongy or cancellous bone with good vascularisation. In the cervical and crestal regions of the implants, soft peri-implant tissue was present and likely originated from the pedicle skin or the periosteum of the antler. This soft tissue consisted of loose connective tissue covered by a multi-layered epithelium, focal round cell infiltration and granulation tissue. Osteogenesis was detected in the crestal region of the cancellous bone, particularly in specimens retrieved 3 and 4 weeks after surgery (deer nos. 2 and 3). However, similar to the unloaded implant specimens, the loaded implant specimen retrieved at 6 post-operative weeks exhibited very good osseointegration and a compact peri-implant bone with good vascularisation (Figs 5 and 6). Interestingly, the orientation of bone lamellation in the coronal areas was mainly longitudinal and parallel to the implant body axis (Fig 6).
p = peri-implant bone; toluidine blue staining, reconstruction, and 5x magnification; Inset: overview of the inserted implant; 1:1.
a) Peri-implant gap along the implant body at 3 weeks after insertion, star: gap; b) high-magnification image of the compact bone along the midshaft implant surface at 6 weeks after insertion; c) high-magnification image of the compact bone as in b); please note the abundance of blue stained vessels in the peri-implant bone in b) and c). d) Osteocytes of the peri-implant bone are in close contact with the implant surface (open arrows) at 6 weeks after insertion; toluidine blue staining, 10x magnification (a and b), 20x magnification (c), 50x magnification (d); p = peri-implant bone, i = implant.
Numerical results
To evaluate the stress and strain, a 3-mm peri-implant antler tissue was selected. Stresses in antler tissue increased from 2.4 MPa (3 weeks after surgery) to 6.5 MPa (5 weeks after surgery) after immediate loading and decreased to 1.7 MPa after 6 weeks of loading. The values in the unloaded models displayed a similar range (1.0–1.3 MPa). The distribution of the stresses in antler tissues for all models was similarly concentrated in the antler tissue around the neck of the implant.
Strain in antler tissues decreased during the healing time for the loaded models, the 3-week (9,878 μstrain) and 6-week loaded models (49 μstrain), and illustrated the highest and lowest maximum strain values among the antler tissues. For the models from deer no. 2, the maximum strain in antler tissue in the loaded model was higher than that in the unloaded model. In contrast, the opposite results were obtained in the models from deer no. 5 (Fig 7).
Strains observed in the antler tissues 6 weeks after loading (left) and in the unloaded specimen from the same antler (right).
Discussion
Hard antlers are well suited mechanically since they are subject to high-impact loading and large bending moments [10,13,25,26]. The mechanical properties of hard antlers are highly anisotropic with the longitudinal elastic modulus, and higher bending, tensile and compressive strengths are observed in this direction than in the transverse direction [17]. Antlers dry out completely following the shedding of velvet [13] and transform into dead structures with the absence of further growth or bone remodelling until antler replacement [27].
Cortical porosity may vary along the main shaft [27]. The porosity is low in the lower and middle thirds of the shaft due to the more rapid completion of cortex formation prior to velvet shedding [27]. The more distal parts of the antler may be more porous, as velvet shedding interrupts the ongoing mineralisation process in the primary osteons. Thus, cortical porosity in the antler may not be the result of remodelling activity but may be the result of incomplete bone formation [16,27].
Antlers are predominantly composed of primary osteons [15,28]. In contrast, human bone is a secondary bone formed by the resorption of previously existing bone tissue and its replacement by new bone [26]. This process results in the formation of secondary osteons [29]. All secondary osteons include a prominent hyper-mineralised region surrounding the primary osteons [28,29]. In contrast, in human bone, a thin mineralised region, the cementum line, surrounds the secondary osteons [30]. Both types of osteons have strong implications for fractures and are prominent sites for microcracking [26,31,32]. However, the yield strength of antler compact bone in the transverse direction is as low as 71 MPa [25], whereas the corresponding yield strength of human cortical bone is approximately 110–120 MPa.
The results showed that the present trial did not disturb the normal behaviour of the deer or antler regeneration. Therefore, antlers can be safely used as a novel method for implantation research with a high value in terms of the refinement of the animal trial for research purposes. Implants are easily inserted into the deer antler using a clinical procedure with traditional implantation instruments. Loading was successful and well controlled when added onto the abutments by self-developed loading devices. No implants were lost during the trial. Thus, the use of deer antlers combined with the novel loading device is a successful model for immediately loaded implant investigations.
Experimental specimens must be observed at different time intervals to understand the behaviour of the implants and surrounding tissues after immediate loading. However, animals must be sacrificed to perform a histological analysis of the bone bed. Moreover, in traditional animal models, the load application on implants is difficult to control because the installation of the loading device in the mouth or on top of other bone sites is affected by many factors such as food intake and physiological activity. In this study, a special self-developed loading device was placed externally at the antler and offered good accessibility and the application of a specific load without the abovementioned limiting factors. However, myiasis was prevented by a thorough velvet suture and application of a spray bandage at this external location, which would not have been a high risk inside the oral cavity. Using the loading device, the magnitude, direction and period of loading were controlled, thus avoiding other interfering factors and allowing the healing process to be monitored easily at different time intervals under immediate loading conditions.
After shedding the antler, the BMD of antler tissue from the unloaded specimens exhibited a similar value of 1.30 ± 0.11 g/cm3. These values were consistent with the results of the study by Chen et al. [25], who discovered that the total bone density of the antler was 1.35 ± 0.01 g/cm3. The antler density of the loaded specimens observed in this study was higher than that of the unloaded specimens in single animals. Thus, the density of the antler tissue around the implant continuously increases over the loading period. However, the density might be reduced after the complete osseointegration of the implant, as shown in previous studies [33,34].
The histological results revealed excellent osseointegration, with a mostly compact peri-implant antler bone exhibiting growth in the crestal direction along the implant surfaces. This finding is comparable to those of studies using other animal models [35–37]. Based on these findings, the deer antler is a novel and valid animal model that simulates the clinical implant healing process.
The deformation of the bone tissue by strain is inversely correlated to its stiffness. The higher the strain value, the lower the stiffness of the bone. The strain in the antler tissues of the loaded model was noticeably lower than that in the unloaded model. Thus, the osseointegration process of implants is faster under the loading condition than under the non-loading condition. These results are very important and present the deer antler as a novel, valid animal model to simulate the clinical implant healing process.
Acknowledgments
The authors thank the staff of Raptor Center and Wildlife Parc Hellenthal, especially Mr Joerg Niesters, Mr Karl Fischer, Mr Dirk Wynands and Dr Martin Boettcher, for the care of the animals. The authors also thank the staff of the Endowed Chair of Oral Technology, University of Bonn, Dr Susanne Reimann and Ms Anna Weber for preparing and scanning the specimens by μCT scanner, and Mr Tim Klunter for removing the specimens from the antlers.
References
- 1. Abboud M, Koeck B, Stark H, Wahl G, Paillon R. Immediate loading of single-tooth implants in the posterior region. Int. J. Oral Maxillofac. Implants. 2005; 20: 61–68. pmid:15747675
- 2. Götz W, Gedrange T, Bourauel C, Hasan I. Clinical, biomechanical and biological aspects of immediately loaded dental implants: a critical review of the literature. Biomed. Tech. (Berl). 2010; 55: 311–315.
- 3. Rea M, Lang NP, Ricci S, Mintrone F, González G, Botticelli D. Healing of implants installed in over- or under-prepared sites: an experimental study in dogs. Clin. Oral Implants Res. 2015; 26: 442–426. pmid:24684411
- 4. Alharbi HM, Babay N, Alzoman H, Basudan S, Anil S, Jansen JA. Bone morphology changes around two types of bone-level implants installed in fresh extraction sockets: a histomorphometric study in Beagle dogs. Clin. Oral Implants Res. 2015; 26, 1106–1112. pmid:24690000
- 5.
Goss RJ. Epimorphic regeneration in mammals. In: Hunt TK, Heppenstall RB, Pines E, Rovee RB, editors. Soft and Hard Tissue Repair. New York: Praeger; 1984. pp.554–573.
- 6.
Bubenik GA. The antler as a model in biomedical research. In: Bubenik GA, Bubenik AB, editors. Horns, Pronghorns, and Antlers. New York: Springer; 1990. pp.474–487.
- 7. Price JS, Allen S, Faucheux C, Althnaian T, Mount JG. Deer antlers: a zoological curiosity or the key to understanding organ regeneration in mammals? J. Anat. 2005; 207: 603–618. pmid:16313394
- 8. Kierdorf U, Li C, Price JS. Improbable appendages: deer antler renewal as a unique case of mammalian regeneration. Semin. Cell Dev. Biol. 2009; 20: 535–542. pmid:19084608
- 9. Kierdorf U, Kierdorf H. Deer antlers: a model of mammalian appendage regeneration: an extensive review. Gerontology. 2011; 57: 53–65. pmid:20332600
- 10. Kierdorf U, Flohr S, Gomez S, Landete-Castillejos T, Kierdorf H. The structure of pedicle and hard antler bone in the European roe deer (Capreolus capreolus): a light microscope and backscattered electron imaging study. J. Anat. 2013; 223: 364–384. pmid:23961846
- 11. Gaspar-López E. Biometrics, testosterone, cortisol and antler growth cycle in Iberian red deer stags (Cervus elaphus hispanicus). Reprod. Domest. Anim. 2010; 45: 243–249. pmid:18992114
- 12. Gomez JA, García AJ, Landete-Castillejos T, Gallego L. Effect of advancing births on testosterone until 2.5 years of age and puberty in Iberian red deer (Cervus elaphus hispanicus). Anim. Reprod. Sci. 2006; 96: 79–88. pmid:16406397
- 13. Currey JD, Landete-Castillejos T, Estevez J, Ceacero F, Olguin A, Garcia A, et al. The mechanical properties of red deer antler bone when used in fighting. J. Exp. Biol. 2009; 212: 3985–3993. pmid:19946076
- 14. Meng S, Zhang X, Xu M, Heng BC, Dai X, Mo X, et al. Effects of deer age on the physicochemical properties of deproteinized antler cancellous bone: an approach to optimize osteoconductivity of bone graft. Biomed Mater. 2015; 4: 035006.
- 15. Szuwart T, Kierdorf H, Kierdorf U, Clemen G. Histochemical and ultrastructural studies of cartilage resorption and acid phosphatase activity during antler growth in fallow deer (Dama dama). Anat. Rec. 2002; 268: 66–72. pmid:12209566
- 16. Landete-Castillejos T, Currey JD, Ceacero F, García AJ, Gallego L, Gomez S. Does nutrition affect bone porosity and mineral tissue distribution in deer antlers? The relationship between histology, mechanical properties and mineral composition. Bone. 2012; 50: 245–254. pmid:22071000
- 17. Rahimi A, Klein R, Keilig L, Abboud M, Wahl G, Bourauel C. Development and design of a novel loading device for the investigation of bone adaptation around immediately loaded dental implants using the reindeer antler as implant bed. J. Biomech. 2009; 42: 2415–2418. pmid:19733856
- 18. Hafner S, Wiesner H, von Hegel G, Halm S, Erhardt W. The antagonism of ketamine/xylazine anesthesia (" Hellabrunn mixture") in wild zoo ruminants. Berl. Munch. Tierartl. 1989; 102: 181–184.
- 19.
Caulkett N, Haigh JC. Deer (Cervids). In: West G, Heard D, Caulkett N, editors. Zoo animal and wildlife immobilization and anaesthesia. Ames. Iowa: Blackwell Publishing; 2007. pp. 607–612.
- 20. Wilson PR, Stafford KJ, Thomas DJ, Mellor DJ. Evaluation of techniques for lidocaine hydrochloride analgesia of the velvet antlers of adult stags. N. Z. Vet. J. 2000; 48: 182–187. pmid:16032150
- 21. Walsh VP, Wilson PR. Chemical analgesia for velvet antler removal in deer. N. Z. Vet. J. 2002; 50: 237–243. pmid:16032279
- 22. Chiapasco M, Casentini P, Zaniboni M, Corsi E, Anello T. Titanium-zirconium alloy narrow-diameter implants (Straumann Roxolid(®)) for the rehabilitation of horizontally deficient edentulous ridges: prospective study on 18 consecutive patients. Clin Oral Implants Res. 2012; 23:1136–41. pmid:22092806
- 23. Beaupré GS, Orr TE, Carterm DR. An approach for time-dependent bone modeling and remodeling-theoretical development. J. Orthop. Res. 1990; 8: 651–61. pmid:2388105
- 24. Tassani S, Ohman C, Baruffaldi F, Baleani M, Viceconti M. Volume to density relation in adult human bone tissue. J. Biomech. 2011; 44: 103–108. pmid:20850118
- 25. Chen PY, Stokes AG, McKittrick J. Comparison of the structure and mechanical properties of bovine femur bone and antler of the North American elk (Cervus elaphus canadensis). Acta. Biomater. 2009; 5: 693–706. pmid:18951859
- 26. Launey ME, Chen PY, McKittrick J, Ritchie RO. Mechanistic aspects of the fracture toughness of elk antler bone. Acta. Biomater. 2010; 6:1505–1514. pmid:19941980
- 27. Gomez S, Garcia AJ, Luna S, Kierdorf U, Kierdorf H, Gallego L, et al. Labeling studies on cortical bone formation in the antlers of red deer (Cervus elaphus). Bone. 2013; 52: 506–515. pmid:23000508
- 28. Skedros JG, Durand P, Bloebaum RD. Hypermineralized peripheral lamellae in primary osteons of deer antler: potential functional analogs of cement lines in mammalian secondary bone. J. Bone Miner. Res. 1995; 10: S441.
- 29. Landete-Castilleijos T, Currey JD, Estevez JA, Gasparlópez E, Garcia A, Gallego L. Influence of physiological effort of growth and chemical composition onantler bone mechanical properties. Bone. 2007; 41: 794. pmid:17822969
- 30. Skedros JG, Holmes JL, Vajda EG, Bloebaum RD. Cement lines of secondary osteons in human bone are not mineral-deficient: new data in a historical perspective. Anat. Rec. A. 2005; 286A: 781.
- 31. Burr DB, Schaffle MB, Frederickson RG. Composition of the cement line and its possible mechanical role as a local interface inhuman compact-bone. J. Biomech. 1988; 21: 939. pmid:3253280
- 32. Yeni YN, Norman TL. Calculation of porosity and osteonal cement line effects on the effective fracture toughness of cortical bone in longitudinal crack growth. J. Biomed. Mater. Res. 2000; 51: 504. pmid:10880095
- 33. Ramachandran A, Singh K, Rao J, Mishra N, Jurel SK, Agrawal KK. Changes in alveolar bone density around immediate functionally and nonfunctionally loaded implants. J. Prosthet. Dent. 2016; 115: 712–717. pmid:26803180
- 34. Mainetti T, Lang NP, Bengazi F, Sbricoli L, Soto Cantero L, Botticelli D. Immediate loading of implants installed in a healed alveolar bony ridge or immediately after tooth extraction: an experimental study in dogs. Clin. Oral Implants Res. 2015; 4: 435–441.
- 35. Feng SW, Ho KN, Chan YH, Chang KJ, Lai WY, Huang HM. Damping Factor as a Diagnostic Parameter for Assessment of Osseointegration during the Dental Implant Healing Process: an Experimental Study in Rabbits. Ann. Biomed. Eng. 2016; 44: 3668–3678. pmid:27307008
- 36. Trisi P, Berardini M, Falco A, Podaliri Vulpiani M. Effect of Implant Thread Geometry on Secondary Stability, Bone Density, and Bone-to-Implant Contact: a Biomechanical and Histological Analysis. Implant Dent. 2015; 24: 384–391. pmid:25939083
- 37. Gottlow J, Dard M, Kjellson F, Obrecht M, Sennerby L. Evaluation of a new titanium-zirconium dental implant: a biomechanical and histological comparative study in the mini pig. Clin. Implant Dent. Relat. Res. 2012; 14: 538–545. pmid:20586785