Figures
Abstract
We investigated the effects of moderate hypoxia (FiO2 = 15%) on different kinetics between pulmonary ventilation () and heart rate (HR) during treadmill walking. Breath-by-breath
, oxygen uptake (
), carbon dioxide output (
), and HR were measured in 13 healthy young adults. The treadmill speed was sinusoidally changed from 3 to 6 km·h-1 with four oscillation periods of 1, 2, 5, and 10 min. The amplitude (Amp), phase shift (PS) and mean values of these kinetics were obtained by harmonic analysis. The mean values of all of these responses during walking at a sinusoidally changing speed became greater under hypoxia compared to normoxia (FiO2 = 21%), indicating that moderate hypoxia could achieve an increased energy expenditure (increased
and
) and hyperventilation. The Amp values of the
,
, and
kinetics were not significantly different between normoxia and hypoxia at most periods, although a significantly smaller Amp of the HR was observed at faster oscillation periods (1 or 2 min).The PS of the HR was significantly greater under hypoxia than normoxia at the 2, 5, and 10 min periods, whereas the PS of the
,
, and
responses was not significantly different between normoxia and hypoxia at any period. These findings suggest that the lesser changes in Amp and PS in ventilatory and gas exchange kinetics during walking at a sinusoidally changing speed were remarkably different from a deceleration in HR kinetics under moderate hypoxia.
Citation: Ebine N, Aoki T, Itoh M, Fukuoka Y (2018) Differential kinetics of the cardiac, ventilatory, and gas exchange variables during walking under moderate hypoxia. PLoS ONE 13(7): e0200186. https://doi.org/10.1371/journal.pone.0200186
Editor: Manabu Sakakibara, Tokai University, JAPAN
Received: May 26, 2017; Accepted: June 21, 2018; Published: July 25, 2018
Copyright: © 2018 Ebine et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the paper and its Supporting Information files.
Funding: This study was financially supported in part by Grant-in-Aid for Scientific Research from the Japan Society for the Promotion of Science (23680068 to NE, 22370091 to YF). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Competing interests: The authors have declared that no competing interests exist.
Introduction
Hiking is a very popular pastime in Japan—in fact, approx. "300,000 people have hiked to the top of Mount Fuji alone. Modeling the experience of mountain hiking in an experimental setting can be difficult, since mountain landscapes are rugged and the atmosphere is often hypoxic. In this study, in an attempt to accurately model the physiological cardiovascular responses of walking along mountain paths, we used treadmill walking in combination with the sinusoidal oscillation of walking speed and changes in the inspiratory oxygen concentrations (FiO2).
We also used sinusoidal work loading to more precisely define the kinetic response characteristics [1,2]. Dynamic physiological responsiveness can be estimated by the phase shift (PS) as the time lag and the amplitude (Amp) of the heart rate (HR) ventilatory and gas exchange variables in response to sinusoidal exercise [3–6], which can provide a clear and simple evaluation of an individual’s HR and ventilatory and gas exchange responses.
It has been well established that hypoxia speeds up the kinetics of CO2 output () and ventilation (
) via the peripheral chemoreceptors (i.e., carotid bodies) [7–9]. On the other hand, hypoxia also slows the kinetics of O2 uptake (
) [7,9–13] and HR [7,9,10, 12,13] at the onset of step exercise. The HR and cardiac output (
) values during steady-state exercise are significantly increased under hypoxia compared to normoxia [13]. Thus, hypoxia can change the blood flow into exercising muscle [14] and slow the kinetics of cardiovascular responses during exercise in order to compensate for the utilization of O2 in working muscles. Consequently, the
values are similar between normoxia and hypoxia during steady-state exercise. It was reported that these observations were supported only by steady-state exercise [13,15]. However, severe hypoxia and/or non-steady-state exercise mode (e.g., gradual load variation) would be able to achieve greater energy expenditure (i.e., an increased
and
) even at the same absolute work intensity [15].
In the present study, our goal was to quantify the effects of acute moderate hypoxia on the kinetics of cardiac, ventilatory and gas exchange variables during non-steady-state walking. We hypothesized that inherent hypoxia would decelerate the HR kinetics, whereas it would accelerate the kinetics during sinusoidal walking as a model of mountain hiking. To test this hypothesis, we compared changes in the kinetics of HR,
and gas exchange in response to sinusoidal changes in walking speed between normoxic and moderately hypoxic states.
Subjects and methods
Subjects
Thirteen healthy young volunteers (seven males and six females) with no cardiac, ventilatory, gas exchange or musculoskeletal disorders participated. The mean age, height, and body weight values were 20.5 ± 1.6 years old, 1.66 ± 0.08 m, and 58.0 ± 7.3 kg, respectively (mean ± standard deviation [SD]). Written informed consent was obtained from all subjects after a detailed explanation of all procedures, the purpose of the study, the possible risks, and the benefits of participation. Our study conformed to the Declaration of Helsinki, and the ethical committees of the Prefectural University of Kumamoto and Doshisha University approved all study procedures.
Experimental protocols
This study was carried out on a motor-driven treadmill (modified TMS 2200; Nihon Kohden, Tokyo). All 13 subjects performed a series of submaximal exercise tests as described [16]. The inspired oxygen fraction (FiO2; %) was set at either normobaric normoxia (20.9% FiO2) or moderate normobaric hypoxia (15.0% FiO2) [17–19]. Hypoxic gas was supplied via a 1000-L Douglas bag with a hypoxic gas generator system (Everest Summit II; Will Co., Tokyo). The atmosphere in the normobaric environmental chamber was set at 25°C with a relative humidity of 50%.
Following a 4 min warm-up by the subject consisting of walking at a constant speed at the midpoint of the sinusoid (4.5 km·h-1), we changed the treadmill speed with a sinusoidal pattern from 3 km·h-1 to 6 km·h-1 at a periods (T) of 10, 5, 2 or 1 min (Fig 1). Before the sinusoidal pattern, a stepwise manner (steady-state) pattern at speeds of 3 km·h-1 and 6 km·h-1 for 5 min and 3 min each was carried out [3,16,20]. The sinusoidal loading was repeated for six cycles at 1-min period and continued for three cycles at 2-min period after a warm-up at a constant work load at the midpoint between maximum and minimum. On another day, another sinusoidal loading was repeated for three cycles at 5-min period and continued for two cycles at 10-min period after 5 min warm-up. Each sinusoidal period of oscillation was studied on a separate occasion (one session at a time, two sessions per week for each individual). The subjects walked on the treadmill at a freely chosen pace. The order of normoxic and hypoxic conditions was randomized, and the subjects performed one of these experimental measurements on one experimental day.
Treadmill walking was started after 5 min of rest, and consisted of 5 min at 3 km·h−1, 3 min at 6 km·h−1, and 4 min at 4.5 km·h−1 for a total of 12 min of walking. After three consecutive exercises, the sinusoidal speed change between 3 and 6 km·h−1 was controlled by a PC in four different periods (1, 2, 5, and 10 min) (upper panel). At the same time, the measured breath-by-breath values were obtained (lower panel).
Measurements
A mass-flow sensor (type AB; Minato Medical Sciences, Osaka, Japan) was attached to the expiratory port of the valve of the face mask worn by the subject to continuously record the subject’s expiratory airflow, which was calibrated before each measurement with a 3-L syringe at three different flow rates. We calculated the values by integrating the tidal volume (VT; mL) and breathing frequency (Bf; breaths·min−1) observed from flow tracings recorded at the subject’s mouth. We confirmed that the sensitivity of the hot wire was not changed with changes in the gas composition over the range of the physiological flow variations.
The end-tidal oxygen pressure (PETO2; mmHg) and carbon dioxide pressure (PETCO2; mmHg) were determined by mass spectrometry (WSMR-1400; Westron, Chiba, Japan) from a sample drawn continuously from the inside of the mouthpiece at 1 mL·sec−1. This ‘loss’ of gas volume was not examined in this study, because the loss of 1 mL·sec−1 was much smaller than the inspired and expired airflows [13,15]. Two reference gases of known composition (O2 15.04%, CO2 2.92%, and N2 82.04%; O2 11.93%, CO2 6.96%, and N2 81.11%) and room air were used to calibrate the mass spectrometer.
The volumes, flows, PCO2, and PO2 at the subject’s mouth were recorded in real time at 50 Hz sampling frequency by a computerized online breath-by-breath system (AE-280; Minato Medical Sciences) from time-aligned gas volume and concentration signals. Breath-by-breath (BTPS),
(STPD),
(STPD), VT, Bf, PETCO2, and PETO2 were determined. The electrocardiogram (ECG), taken from a V5lead, was monitored continuously on an wireless ECG monitor (DS-2150; Fukudadenshi, Tokyo), and subject’s heart rate (HR) was measured by beat-by-beat counting of the R-spike of the ECG taken simultaneously with the other measurements. The signal controlling the speed of the motor driving the treadmill was delivered by a microcomputer through a digital-analog converter.
Data analysis
All HR, ventilatory and gas exchange data were analyzed using a standard Fourier analysis as described previously [2,5,6,16,20]. In brief, the variation of the treadmill speed was regarded as the input function. The amplitude (Amp) and phase shift (PS; degree) of the fundamental component of the ,
,
, HR, VT, and Bf were computed as follows:
(1)
and
(2)
where the Re and Im values are the real and imaginary parts of these responses determined after a second-by-second interpolation of these responses (x) as
(3)
(4)
where x(t) is the response value at time t (in seconds), Mx is the mean value of x for an integrated number of cycles (N), T is the period of the input signal (in seconds) and f (= 1/T) is its frequency. The Amp of each
,
,
, HR, VT, and Bf parameter was normalized by dividing the ‘magnitude’ of each parameter obtained during steady-state walking at 3 and 6 km·h−1. We used the average data of the final 1 min of each period of steady-state walking to determine the ‘magnitude’. The Amp is presented as the Amp ratio (%) and the absolute values of the fundamental component of each variable.
Statistical analysis
All values are presented as the mean ± SD. Significant differences in each variable (,
,
, VT, Bf, HR, PETCO2, and PETO2) were determined by a two-way repeated measures analysis of variance (ANOVA) for comparing different FiO2 conditions (normoxia and hypoxia) × oscillation periods (T; 1, 2, 5, and 10 min). Tukey’s post-hoc test was applied for the appropriate data sets if a significant F- value was obtained. The statistical significance was set at p < 0.05.
Results
Although we did not measure the O2 saturation in each subject’s finger, the mean values of PETO2 at the middle walking speed of 4.5 km·h−1 were 105.7 ± 2.8 mmHg under normoxia and 58.1 ± 9.4 mmHg under hypoxia. Fig 2 provides representative ,
,
, HR, VT, and Bf kinetics data for one subject and the calculated fundamental components during sinusoidal walking for all periods. The Amp and PS were shown to be reliable variables for estimating the fundamental component of the ventilatory and gas exchange kinetics under hypoxia.
The responses of a representative subject’s variables of ventilation (), O2 uptake (
), CO2 output (
), heart rate (HR), tidal volume (VT), and breath frequency (Bf) over four different periods of 1, 2, 5, and 10 min are shown. Oscillating lines: Superimposed data on gas exchange variable. Smooth lines: Fundamental sine-wave component of these kinetics.
Ventilatory and gas exchange kinetics between normoxia and hypoxia
During hypoxia, the Amp of the response decreased from 4.39 ± 0.86 L·min−1 (during constant speed exercise) to 1.88 ± 0.83 L·min−1 as the period was shortened (Fig 3A). We observed a significantly greater Amp of the
only during the 5-min period during hypoxia compared to normoxia (p < 0.05). The Amp of the
response during sinusoidal walking decreased from 207 ± 32 ml·min−1 (T: 10 min) to 70 ± 18 ml·min−1 (T: 1 min) under hypoxia.
Differences in the responses of Amp and PS of (A,E),
(B,F),
(C,G), and PETCO2 (D,H) between hypoxia (blue line) and normoxia (red line) as a function of the periods of the sinusoidal changes in the treadmill speed are shown. *p < 0.05, **p < 0.01 for hypoxia vs. normoxia. Data are means ± SD.
There were no significant differences in the Amp of the VO2 in any of the periods between normoxia and hypoxia (Fig 3B). The Amp of decreased from 197 ± 26 ml·min−1 (T: 10 min) to 67 ± 20 ml·min−1 (T: 1 min) without a significant difference between normoxia and hypoxia (Fig 3C). The changes in PETCO2 during hypoxia displayed small Amp oscillations ranging from 1.2 ± 0.3 to1.2 ± 0.7 mmHg, and the Amp values at all periods became significantly smaller under hypoxia compared to those observed at normoxia (Fig 3D, p < 0.01).
The PS of all of the responses gradually increased at shorter periods during walking. The PS of the ,
, and
responses were not significantly different between normoxia and hypoxia in any of the periods. Thus, the PS as an index of the time delay of ventilatory and gas exchange was not influenced by hypoxia (Fig 3E, 3F and 3G). The PS of the PETCO2 response was significantly delayed between normoxia and hypoxia at all periods expect for 10 min (Fig 3H, p < 0.05).
Hypoxic-induced slowing of the HR kinetics during sinusoidal walking
We compared the HR kinetics observed under hypoxia at the 5-min period with those observed under normoxia (Fig 4A). The average of the mean values (Mx) of HR was 97 bpm at all periods under normoxia, and the average of the Mx values of HR at all periods was significantly higher than approx.10 bpm at hypoxia (range: 106 and 110 bpm) (Fig 4B, p < 0.01, p < 0.001). The Amp of HR kinetics at the shorter periods of 1 min and 2 min were significantly smaller under hypoxia than normoxia (Fig 4C, p < 0.05), and the PS became significantly slower under hypoxia at the periods of 2, 5, and 10 min (but not the 1 min period) compared to the corresponding PS values under normoxia (Fig 4D, p < 0.05, p < 0.01, p < 0.001). Thus, hypoxia clearly induced an increase in PS (i.e., time lag) of the HR kinetics during sinusoidal walking.
Differences in the dynamic responses of a representative subject’s HR between normoxia and hypoxia at the representative sinusoidal period of 5 min are shown (A). The Mx (B), Amp (C), and PS (D) are shown for hypoxia (blue lines) and normoxia (red lines) as a function of the periods of the sinusoidal changes in the treadmill speed. *p < 0.05, **p < 0.01, ***p < 0.001 for hypoxia vs. normoxia. Data are means ± SD.
Changes in the mean values of ventilatory and gas exchange variables during sinusoidal walking
The Mx values of the ,
, and
kinetics were significantly different between hypoxia and normoxia (Fig 5A, 5D and 5E). The Mx of
was significantly elevated by 7.3% from 23.33 L·min−1 at normoxia to 25.47 L·min−1 under hypoxia (p < 0.05, p < 0.001). The Mx values of
and
were also increased to 46 and 42 ml·min−1 (6.1%, 4.4%) under hypoxia compared to normoxia (p < 0.05, p < 0.01, p < 0.001) independently of the different periods. The Mx of VT became significantly greater under hypoxia compared to normoxia (p < 0.05, p < 0.001, Fig 5B), whereas the Bf values were not significantly different between normoxia and hypoxia at any periods (Fig 5C). Thus, the greater Mx of
was attributable to the increased VT, not to Bf. By contrast, the Mx of PETCO2 was not significantly different between normoxia and hypoxia at each period, and it was narrowly distributed between 41.3 mmHg and 42.9 mmHg (Fig 5F).
Differences in Mx between hypoxia (blue line) and normoxia (red lines) are shown as a function of the periods of the sinusoidal changes in the treadmill speed. *p < 0.05, **p < 0.01, ***p < 0.001 for hypoxia vs. normoxia. Data are means ± SD.
The ventilatory-gas exchange matching during sinusoidal walking
The Amp ratio (i.e., the Amp ratio for between the constant and sinusoidal variation) of the
response was very closely related to the Amp ratio of
among the data obtained from all periods during hypoxia and normoxia (hypoxia, r = 0.92; normoxia, r = 0.88; p < 0.01) (Fig 6B). The slopes of the regression line for the
and
relationship were similar between hypoxia (0.849) and normoxia (0.966). A significant correlation between the Amp ratio of
and that of
was also observed at both hypoxia (r = 0.84, p < 0.01) and normoxia (r = 0.75, p < 0.01) (Fig 6A). Moreover, the Amp ratio for
was significantly related to that of HR during normoxia (r = 0.33, p < 0.05), but not during hypoxia (r = 0.27, p = 0.73; Fig 6C).
The Amp ratio of the against
(A),
(B), and HR (C) under conditions of either hypoxia or normoxia is shown. Note that the A ratio for the
kinetics followed the Amp ratio for the
kinetics more closely. In contrast, the Amp ratio for HR was not tightly related to the
kinetics. The regression line for the Amp ratio of the
relationship was similar between hypoxia and normoxia: for hypoxia, y = 0.85x + 0.13, r = 0.92 (p < 0.01); for normoxia, y = 0.97x + 0.08, r = 0.88 (p < 0.01).
Discussion
Moderate hypoxia induced significant increases in the mean values of the HR, ,
, and
kinetics, even though our frequency domain analysis of the
,
, and
kinetics during sinusoidal walking revealed that the ventilatory and gas exchange kinetics under moderate hypoxia were similar to those under normoxia. In contrast, the kinetics of the HR response were slower under hypoxia compared to normoxia, and the HR kinetics were remarkably different from the ventilatory and gas exchange kinetics under moderate hypoxia. On the other hand, the slopes of the
and
relationship were not different between normoxia and hypoxia, which suggests that the ventilatory adjustment of hormonal drive (i.e., the CO2 drive) was equivalent between normoxia and hypoxia, even though hypoxic-induced hyperventilation (i.e., the Mx of
) occurred via the peripheral chemoreflex during sinusoidal walking.
Hypoxia-induced slowing of HR kinetics during sinusoidal walking
In the case of mild sinusoidal exercise such as slower walking (average HR ≤ 100 beats·min−1), the HR response will reflect mostly the parasympathetic nervous system [6,16]. Yamamoto et al. [21] demonstrated that cardiac vagal tone was greatly reduced beginning at >110 beats·min−1 in the HR response to incremental work; indeed, the average HR values under five different sinusoidal workloads ranged from 97 to 110 beats·min−1. Because hypoxia evokes sympathetic activity and lessens parasympathetic activity, the increase in the Mx of the HR from 100 bpm to 110 bpm in the present study reduced the parasympathetic activation under hypoxia.
The parasympathetic nervous activity appeared to have been reduced, judging from the greater Mx of the HR under hypoxia, and this seemed to account for the slower HR kinetics compared to normoxia. However, the HR declined to below 110 bpm at the minimum speed of 3 km·h−1, and thus we suspected that the parasympathetic activation would not completely disappear even under hypoxia. By contrast, as the averaged Mx of the HR under normoxia was approx. 100 bpm at any periods, the faster HR kinetics during walking would have occurred due to the alteration of predominant parasympathetic activation. Taken together, our findings demonstrate that the sinusoidal work loading used in the present study has an advantage in that the alteration of the midpoint work load between the minimum and maximum would modify the variation in the balance between sympathetic and parasympathetic outflow during exercise.
Augmented mean values (Mx) of all variables by hypoxia
The Mx values of and
were significantly increased (6.1%, 4.4%) under moderate hypoxia compared to normoxia, as was also observed for the HR (8.8%). These observations provided evidence that non-steady-state exercise might induce an increase in energy expenditure without changing the kinetic characteristics of these variables. Despite this observation, it was unclear why sinusoidal exercise (i.e., non-steady-state exercise) was characterized by a significant increase in cardiac, ventilatory, and metabolic activities even under moderate hypoxic exposures. If patients with diseases such as heart failure or diabetes have limited walking speeds, hypoxia could help them achieve a higher energy expenditure, and a lower walking speed has also been suggested to be more protective of the muscles/joints in obese patients with orthopedic comorbidities than a higher walking speed [22].
Aaron et al. [23] reported that the energy expenditure for breathing (i.e., ) amounted to approx. 2~3% of the total energy expenditure even during light exercise. Previous studies may have overestimated the cost of respiration during locomotion by ignoring the cost of increased HR [23]. However, the increased energy expenditure at severe hypoxia would be derived from the HR and
during walking; in our previous study using a bivariate regression model, the contribution of heart beats accounted for 60%~80% of the approx. 5% increase in energy expenditure during walking [24]. Our present finding of a deceleration in HR kinetics with an increase in the Mx suggests that hypoxia has a greater influence on the HR than on the
during sinusoidal walking. In other words, the energy expenditure of the heart beats may be somewhat greater than that of the breathing during walking under a hypoxic condition.
In another aspect of hypoxic hyperventilation, even though the Mx of was significantly elevated by 7.3% from 23.33 L·min−1 at normoxia to 25.47 L·min−1 at hypoxia (p < 0.05, p < 0.001), the Mx of PETCO2 was not significantly different between normoxia and hypoxia at each period. This observation indicated that hypoxia had induced a change in the chemoreflex drive [7–9], while the PCO2 was maintained at the same level under hypoxia or normoxia during walking at a sinusoidally changing speed. Although the physiological mechanism underlying this phenomenon was not clarified, sinusoidal exercise may provide a useful technique for the determination of the augmented energy expenditure and the increased
with the stable PaCO2.
Ventilatory kinetics in response to exercise under a hypoxic condition
The carotid bodies are considered the primary mediators of kinetics at the transient phase in response to increases in the work rate [25]. It has been shown that under conditions of increased carotid-body gain induced by hypoxia, kinetics are accelerated [7,8,26]. Conversely, reduced carotid-body gain in response to induced hyperoxia [7,8,26] or carotid-body resection [25] resulted in slowed
kinetics. In the present study, we did not observe faster
kinetics during sinusoidal walking even under moderate hypoxia, which suggests that the carotid-body gain in response to O2 is less affected by moderate hypoxia. At the same time, the
kinetics during walking showed a similar trend under normoxia and hypoxia, and thus it appears that hypoxic-induced hyperventilation can move the
response upward directly, but has less of an effect on the
kinetics under moderate hypoxia.
The increased observed in the present study was attributed to the increased VT, not to Bf. In their review regarding the effect of the interaction between VT and Bf on the ventilatory response to various stresses, Tipton et al. [27] demonstrated that the increased
drive during moderate hypoxic exposure appears to be linked primarily to an increased VT in humans (see Fig 4). These findings may support the concept that the increased VT contribute more to the augmented
during sinusoidal walking under moderate hypoxia compared to Bf.
Hypoxia would also induce less Amp and greater PS in the PETCO2 response at all of the periods (using mathematical analysis) compared to those at normoxia. Consequently, the Mx values of the PETCO2 were similar between normoxia and hypoxia at all periods. We considered that the Amp in PETCO2 was less 1.3 mmHg, which was low enough to allow us to ignore the variation in PETCO2 (i.e., the PETCO2 response remained stable), and the PS of PETCO2 was also meaningless from a physiological perspective. In other words, the alteration of PETCO2 could reflect an error signal to the arterial and central chemoreceptors, which are further related to .
An important point needs to be clarified regarding PaCO2 homeostatics during hypoxic exercise. Previous investigations showed that during a sinusoidal change in walking speed, ventilatory-gas exchange matching occurred to prevent an abrupt increase in PaCO2, which would be derived from an increase in , thereby minimizing the changes in PaCO2 at an abrupt change in the exercise intensity [28–31]. This elaborate ventilatory system during mild exercise (i.e., walking) can be controlled under moderate hypoxia. However, in the cases in which more severe hypoxia is present during walking (e.g., at altitudes > 3,000m), it is not clear whether ventilatory and gas exchange matching will occur. In addition, the effective interaction between
and
kinetics may be supported by the findings we observed herein under hypoxic and normoxic conditions.
Conclusion
In conclusion, moderate hypoxia could achieve an increase in the energy expenditure (i.e., increased and
) and the increased
appeared to have occurred via the peripheral chemoreflex during non-steady-state walking at a sinusoidally changing speed. Our findings can advance the promotion of non-steady-state exercise protocols (e.g., sinusoidal walking) as available exercise for a greater energy demand even at lower exercise intensity in obese individuals and those with impaired movement. However, hypoxia produced the lesser changes in Amp and PS in ventilatory and gas exchange kinetics and the strong linkage between
and
, which suggests that the ventilatory adjustment of hormonal drive (i.e., CO2 drive) was equivalent between normoxia and hypoxia. Our study has demonstrated that the ventilatory and gas exchange kinetics were remarkably different from a deceleration in HR kinetics under moderate hypoxia.
Supporting information
S1 Table. Amplitudes of gas exchange variables during sinusoidal walking under hypoxia and normoxia.
Breath-by-breath ventilation (, BTPS), O2 uptake (
, STPD), CO2 output (
, STPD), and heart rate (HR) were determined. Data are shown by mean ± SD.
https://doi.org/10.1371/journal.pone.0200186.s001
(PDF)
S2 Table. Phase shifts of gas exchange variables during sinusoidal walking under hypoxia and normoxia.
Breath-by-breath ventilation (, BTPS), O2 uptake (
, STPD), CO2 output (
, STPD), and heart rate (HR) were determined. Data are shown by mean ± SD.
https://doi.org/10.1371/journal.pone.0200186.s002
(PDF)
S3 Table. Mean values of gas exchange variables during sinusoidal walking under hypoxia and normoxia.
Breath-by-breath ventilation (, BTPS), O2 uptake (
, STPD), CO2 output (
, STPD), heart rate (HR), tidal volume (VT), breaths frequency (Bf), and end-tidal PCO2 (PETCO2) were determined. Data are shown by mean ± SD.
https://doi.org/10.1371/journal.pone.0200186.s003
(PDF)
References
- 1. Fukuoka Y, Gwon O, Sone R, Ikegami H. Characterization of sports by the dynamics of athletes in response to sinusoidal work load. Acta Physiol Scand. 1995;153: 117–124. pmid:7778451
- 2. Miyamoto Y, Nakazono Y, Hiura T, Abe Y. Cardiorespiratory dynamics during sinusoidal and impulse exercise in man. Jpn J Physiol. 1983; 33: 971–986. pmid:6425544
- 3. Bakker HK, Struikenkamp RS, De Vries GA. Dynamics of ventilation, heart rate, and gas exchange: sinusoidal and impulse work loads in man. J Appl Physiol 1980; 48: 289–301. pmid:7364615
- 4. Casaburi R, Whipp BJ, Wasserman K, Beaver WL, Koyal SN. Ventilatory and gas exchange dynamics in response to sinusoidal work. J Appl Physiol. 1977; 42: 300–301. pmid:838654
- 5. Haouzi P, Fukuba Y, Peslin R, Chalon B, Marchal F. Crance JP. Ventilatory dynamics in children and adults during sinusoidal exercise. Eur J Appl Physiol Occup Physiol. 1992; 64: 410–418. pmid:1612079
- 6. Fukuoka Y, Nakagawa Y, Ogoh K, Shiojiri T, Fukuba Y. Dynamics of the heart rate response to sinusoidal work in humans: influence of physical activity and age. Clin Sci (Lond). 2002; 102: 31–38.
- 7. Griffiths TL, Henson LC, Whipp BJ. Influence of inspired oxygen concentration on the dynamics of the exercise hyperpnoea in man. J Physiol. 1986; 380: 387–403. pmid:3612567
- 8. Ward SA, Blesovsky L, Russak S, Ashjian A, Whipp BJ. Chemoreflex modulation of ventilatory dynamics during exercise in humans. J Appl Physiol. 1987; 63: 2001–2007. pmid:3121578
- 9. Xing HC, Cochrane JE, Yamamoto Y, Hughson RL. Frequency domain analysis of ventilation and gas exchange kinetics in hypoxic exercise. J Appl Physiol. 1991; 71: 2394–2401. pmid:1778938
- 10. Linnarsson D. Dynamics of pulmonary gas exchange and heart rate changes at start and end of exercise. Acta Physiol Scand (Suppl). 1974; 415: 1–68.
- 11. Murphy PC, Cuervo LA, Hughson RL. A study of cardiorespiratory dynamics with step and ramp exercise tests in normoxia and hypoxia. Cardiovasc Res. 1989; 23: 825–832. pmid:2620311
- 12. Engelen M, Porszasz J, Riley M, Wasserman K, Maehara K, Barstow TJ. Effects of hypoxic hypoxia on O2 uptake and heart rate kinetics during heavy exercise. J Appl Physiol. 1996; 81: 2500–2508. pmid:9018498
- 13. Hotta N, Abe D, Yoshida T, Aoki T, Fukuoka Y. Influence of work rate on dynamics of O2 uptake under hypoxic conditions in humans. J Sports Med Phys Fitness. 2008; 48: 129–137. pmid:18427405
- 14. Rowell LB, Saltin B, Kiens B, Christensen NJ. Is peak quadriceps blood flow in humans even higher during exercise with hypoxemia? Am J Physiol. 1986; 251(5 Pt 2): H1038–H1044. pmid:3777192
- 15. Horiuchi M, Handa Y, Abe D, Fukuoka Y. Walking economy at simulated high altitude in human healthy young male lowlanders. Biol Open. 2016; 15: 1408–1414. pmid:27744292
- 16. Fukuoka Y, Iihoshi M, Nazunin JT, Abe D, Fukuba Y. Dynamic Characteristics of Ventilatory and Gas Exchange during Sinusoidal Walking in Humans. PLoS One. 2017; 12: e0168517. pmid:28076413
- 17. Haufe S, Wiesner S, Engeli S, Luft FC, Jordan J. Influences of normobaric hypoxia training on metabolic risk markers in human subjects. Med Sci Sports Exerc. 2008; 40: 1939–1944. pmid:18845972
- 18. Kong Z, Fan X, Sun S, Song L, Shi Q, Nie J. Comparison of high-intensity interval training and moderate-to-vigorous continuous training for cardiometabolic health and exercise enjoyment in obese young women: A randomized controlled trial. PLoS One. 2016; 11: e0158589. pmid:27368057
- 19. Gatterer H, Haacke S, Burtscher M, Faulhaber M, Melmer A, Ebenbichler C, et al. Normobaric intermittent hypoxia over 8 months does not reduce body weight and metabolic risk factors—a randomized, single blind, placebo-controlled study in normobaric hypoxia and normobaric sham hypoxia. Obes Facts. 2015; 8: 200–209. pmid:26008855
- 20. Haouzi P, Chenuel B, Chalon B. The control of ventilation is dissociated from locomotion during walking in sheep. J Physiol. 2004; 559: 315–325. pmid:15235099
- 21. Yamamoto Y, Hughson, RL, and Peterson JC. Autonomic control of heart rate during studied by heart rate variability spectral analysis. J Appl Physiol. 1991; 71: 1136–1142. pmid:1757310
- 22. Wiesner S, Haufe S, Engeli S, Mutschler H, Haas U, Luft FC, et al. Influences of normobaric hypoxia training on physical fitness and metabolic risk markers in overweight to obese subjects. Obesity (Silver Spring). 2010; 18: 116–120. pmid:19543214
- 23. Aaron EA, Johnson BD, Seow CK, Dempsey JA. Oxygen cost of exercise hyperpnea: measurement. J Appl Physiol. 1992; 72: 1810–1817. pmid:1601790
- 24. Horiuchi M, Fukuoka Y, Handa Y, Abe D, Pontzer H. Measuring the energy of ventilation and circulation during human walking using induced hypoxia. Sci Rep. 2017; 10: 4938. pmid:28694491
- 25. Wasserman K, Whipp BJ, Koyal SN, Cleary MG. Effect of carotid body resection on ventilatory and acid-base control during exercise. J Appl Physiol. 1975; 39: 354–358. pmid:240799
- 26. Hughson RL. Coupling of ventilation and gas exchange during transitions in work rate by humans. Respir Physiol. 1995; 101: 87–98. pmid:8525125
- 27. Tipton MJ, Harper A, Paton JFR, Costello JT. The human ventilatory response to stress: rate or depth? J Physiol. 2017; 595: 5729–5752. pmid:28650070
- 28. Babb TG. Ventilatory response to exercise in subjects breathing CO2 or HeO2. J Appl Physiol. 1997b; 82: 746–754.
- 29. Bennett FM, Fordyce WE. Gain of the ventilatory exercise stimulus: definition and meaning. J Appl Physiol. 1988; 65: 2011–2017. pmid:3145273
- 30. Forster HV, Dunning MB, Lowry TF, Erickson BK, Forster MA, Pan LG, et al. Effect of asthma and ventilatory loading on arterial PCO2 of humans during submaximal exercise. J Appl Physiol. 1993; 75: 1385–1394. pmid:8226555
- 31. Mitchell GS. Ventilatory control during exercise with increased respiratory dead space in goats. J Appl Physiol. 1990; 69: 718–727. pmid:2228882