Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Laboratory- and community-based health outcomes in people with transtibial amputation using crossover and energy-storing prosthetic feet: A randomized crossover trial

  • Sara J. Morgan,

    Roles Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Writing – original draft, Writing – review & editing

    Affiliation Department of Rehabilitation Medicine, University of Washington, Seattle, WA, United States of America

  • Cody L. McDonald,

    Roles Conceptualization, Data curation, Investigation, Writing – review & editing

    Affiliation Department of Rehabilitation Medicine, University of Washington, Seattle, WA, United States of America

  • Elizabeth G. Halsne,

    Roles Data curation, Investigation, Writing – review & editing

    Affiliation Department of Rehabilitation Medicine, University of Washington, Seattle, WA, United States of America

  • Sarah M. Cheever,

    Roles Data curation, Investigation, Writing – review & editing

    Affiliation Department of Rehabilitation Medicine, University of Washington, Seattle, WA, United States of America

  • Rana Salem,

    Roles Data curation, Writing – review & editing

    Affiliation Department of Rehabilitation Medicine, University of Washington, Seattle, WA, United States of America

  • Patricia A. Kramer,

    Roles Conceptualization, Methodology, Writing – review & editing

    Affiliation Department of Anthropology, University of Washington, Seattle, WA, United States of America

  • Brian J. Hafner

    Roles Conceptualization, Data curation, Funding acquisition, Investigation, Methodology, Project administration, Supervision, Validation, Writing – review & editing

    bhafner@uw.edu

    Affiliation Department of Rehabilitation Medicine, University of Washington, Seattle, WA, United States of America

Abstract

Contemporary prosthetic feet are generally optimized for either daily or high-level activities. Prosthesis users, therefore, often require multiple prostheses to participate in activities that span a range of mobility. Crossover feet (XF) are designed to increase the range of activities that can be performed with a single prosthesis. However, little evidence exists to guide clinical prescription of XF relative to traditional energy storing feet (ESF). The objective of this study was to assess the effects of XF and ESF on health outcomes in people with transtibial amputation. A randomized crossover study was conducted to assess changes in laboratory-based (endurance, perceived exertion, walking performance) and community-based (step activity and self-reported mobility, fatigue, balance confidence, activity restrictions, and satisfaction) outcomes. Twenty-seven participants were fit with XF and ESF prostheses with standardized sockets, interfaces, and suspensions. Participants were not blinded to the intervention, and wore each prosthesis for one month while their steps were counted with an activity monitor. After each accommodation period, participants returned for data collection. Endurance and perceived exertion were measured with the Six-Minute Walk Test and Borg-CR100, respectively. Walking performance was measured using an electronic walkway. Self-reported mobility, fatigue, balance confidence, activity restrictions, and satisfaction were measured with survey instruments. Participants also reported foot preferences upon conclusion of the study. Differences between feet were assessed with a crossover analysis. While using XF, users experienced improvements in most community-based outcomes, including mobility (p = .001), fatigue (p = .001), balance confidence (p = .005), activity restrictions (p = .002), and functional satisfaction (p < .001). Participants also exhibited longer sound side steps in XF compared to ESF (p < .001). Most participants (89%) reported an overall preference for XF; others (11%) reported no preference. Results indicate that XF may be a promising alternative to ESF for people with transtibial amputation who engage in a range of mobility activities.

Trial registration: ClinicalTrials.gov NCT02440711

Introduction

Increasingly sophisticated prosthetic feet have been developed over the past three decades to enable users to participate in a variety of activities, including walking, running, and playing sports.[1] However, each prosthetic foot design is generally optimized for performance across a narrow range of activities and may inhibit use in other areas. For example, energy storing feet (ESF, Fig 1) are designed to both support users in static standing and facilitate their ability to walk at various speeds. ESF employ modern materials and geometric configurations designed to store and return energy in walking, much like a mechanical spring.[2] Prosthetic limbs with ESF allow users to return to an active lifestyle, but restrict running speed and aerobic performance compared to prosthetic feet designed for high speeds.[3] Running-specific feet (RSF), such as the Össur Cheetah (Össur hf, Reykjavik, Iceland), allow people with lower limb amputation to participate in demanding athletic activities.[4,5] While RSF are well-suited for running and sprinting, the absence of a heel and split keel decreases stability in standing, walking, and other low- and moderate-impact activities.[6] Thus, active users often require a primary prosthesis with an ESF and a sports prosthesis with an RSF or other specialized foot to participate optimally in a broad range of activities (Fig 2).[6,7]

thumbnail
Fig 2. Activities along the mobility spectrum that ESF, RSF, and XF are estimated to span for most prosthetic limb users.

The black sections of the arrows indicate that the foot is well-designed for these activites, the faded sections indicate that the foot design can be used for these activities, however, performance may be suboptimal.

https://doi.org/10.1371/journal.pone.0189652.g002

Combined use of primary and sports prostheses may allow people to engage in a variety of low-, moderate-, and high-impact activities. However, obtaining and maintaining multiple prostheses may present barriers to many active prosthetic limb users. First, procuring a sports prosthesis is expensive–many insurance companies only cover the beneficiary’s primary prostheses and generally deem secondary prostheses not to be medically necessary.[8] Thus, users must often pay out-of-pocket for sports prostheses. Second, sports prostheses require regular maintenance, similar to the individual’s primary prosthesis. Prosthesis users must regularly return to their prosthetist for adjustments as components wear or the fit of their prosthesis changes over time.[6,7,9] These adjustments can be time-consuming, particularly when a second prosthesis must be modified. Another barrier to use of sports prostheses is the inconvenience of switching back and forth between prostheses as users transition among different activities. These breaks in activity are inefficient and burdensome for prosthesis users and could limit users’ ability to engage in high-impact activities. Together, the cost, maintenance, and burden of alternating prostheses may restrict participation in occasional or regular physical activity for many prosthesis users. In lieu of obtaining and maintaining multiple prostheses, users have expressed a desire for feet designed to accommodate a wider range of activities.[10]

The crossover foot (XF) is a novel prosthetic foot that has been developed to widen the range of activities a user can perform with a single prosthesis. Similar to many ESF, the XF design incorporates a split keel to accommodate uneven terrain, heel springs to facilitate heel-toe walking, and a foot shell to enable the foot to fit in a traditional shoe. However, the XF also includes elements of RSF design, such as an extended, stiff carbon keel blade that attaches directly to the posterior socket. The keel blade of the XF is longer than that of the ESF to increase the energy storage and return properties of the prosthesis (Fig 1). XF are designed for both low-impact activities, such as walking and standing, and high-impact activities, such as jogging and running (Fig 2). A foot like the XF is desirable as it improves the ability to engage in activities across the mobility spectrum without use of multiple prostheses.

At present, limited evidence is available to guide selection of XF technology. Preliminary research demonstrated that users experience modest functional benefits with XF, including better mobility at comfortable and fast speeds, improved endurance, reduced perceived exertion, and longer sound (i.e., non-prosthetic) side steps compared to the ESF conditions.[11] However, these initial findings are from a pilot study with a small sample (n = 7), short accommodation period, and non-standardized prosthetic interventions across study participants. Further, the prior study used a cross-sectional, laboratory-based design that allowed for limited assessment of participants’ experiences in the community. Additional research is therefore needed to facilitate evidence-based prescription of XF prosthetic technologies for routine daily use.

The purpose of this study was to compare a range of health outcomes for individuals with transtibial amputation in two prosthetic foot conditions: XF and ESF. A randomized crossover study was conducted to assess the relative effects of XF and ESF on laboratory-based (i.e., endurance, perceived exertion, walking performance) and community-based outcomes (i.e., step activity and self-reported mobility, fatigue, balance confidence, activity restrictions, and satisfaction). Based on preliminary evidence,[11] we hypothesized that participants would exhibit equivalent or better health outcomes when wearing XF compared to ESF.

Materials and methods

A randomized crossover study (Fig 3) was conducted to compare functional and self-reported health outcomes in participants with transtibial amputation under two different test conditions: wearing a prosthesis with a ESF and wearing a prosthesis with an XF. The order in which study participants received interventions (i.e., XF-ESF or ESF-XF) was randomly assigned. Participants were not blinded to the intervention, and wore each intervention (i.e., XF and ESF) for at least one month to experience the function of each prosthetic foot across a range of settings and activities. All outcomes were assessed at the end of each one-month accommodation period.

thumbnail
Fig 3. Overview of the randomized crossover study design.

https://doi.org/10.1371/journal.pone.0189652.g003

Participants

A convenience sample of individuals with lower limb amputation was recruited to participate in the study. An a priori power analysis from previously-collected data[11] was used to estimate sample size for this study. Mean differences in outcomes also proposed in the present study, including the six-minute walk test distance (mean = 19.7m, SD = 26.6m, effect size = 0.75) and walking speed (mean = 0.05m/s, SD = 0.06m/s, effect size = 0.85) were used in the power analysis. Probability of type I error (α) was set to 0.05, and power (1-β) from 0.80 to 0.95 was assessed to account for limitations in the pilot study design. G*Power 3.1.9.2 (Universität Kiel, Germany) was used to conduct the power analysis. Target sample sizes ranged from 17 to 26 based on 6MWT distances, and from 14 to 21 based on walking speeds reported in the prior study. The target sample was increased to 30 participants to account for attrition in the present study.

Study participants were recruited from local prosthetics facilities with practitioners experienced in fitting XF and ESF. Eligibility criteria included: (1) 18 years of age or older; (2) unilateral, transtibial amputation that occurred more than 1 year before recruitment into study; (3) amputation secondary to non-dysvascular causes; (4) ownership of a well-fitting, functional prosthesis with an ESF or XF; and (5) ability to complete the study protocol (e.g., willingness to wear each prosthetic foot with an activity monitor for a one-month period; ability to walk continuously for at least six minutes without assistance, read and write English, and follow verbal instructions). Potential participants were excluded from the study if they had (1) contralateral lower limb or upper limb amputation or (2) any health condition that would limit completion of the study protocol (e.g., skin breakdown, heart disease).

Blocked random allocation was used to assign participants to order of prosthetic foot interventions (i.e., XF-ESF, ESF-XF). To randomize participants to order, an investigator not involved in enrollment (BH) randomly sorted a list of 32 participant identification numbers. Additional numbers beyond the minimum sample size (n = 26) were randomized to account for attrition. The first 16 randomly sorted numbers were assigned to XF-ESF and the remaining 16 were assigned to ESF-XF. Once the orders of the interventions were assigned, the list was re-sorted in ascending order by identification number. Participants were assigned consecutive identification numbers upon enrollment along with the associated order of foot assignment. Assignment was concealed from participants and the investigators involved in enrollment until the participant was enrolled in the study.

Experimental conditions

The intervention condition for this study was a transtibial prosthesis with an XF (Össur Cheetah Xplore®, Össur hf, Reykjavik, Iceland). The comparison condition was a transtibial prosthesis with an ESF (Össur Vari-Flex®). ESF like the Vari-Flex® are commonly prescribed for many moderate-to-high activity patients with lower limb amputation. As such, Vari-Flex® feet are a direct clinical alternative to XF.

XF and ESF prostheses were custom-fabricated for each participant by their prosthetist. Given the direct-lamination attachment of the XF to the prosthetic socket, the same socket could not be used for both conditions. Therefore, duplicate sockets were fabricated for each study participant. Each participant’s XF and ESF sockets shared a custom flexible inner socket that was transferred between the prostheses to provide equivalent socket fit and comfort between prosthetic conditions. Participants also used identical interfaces (e.g., prosthetic liners) and suspension mechanisms (e.g., elevated vacuum). Footwear was standardized between test conditions. Socket adjustments to optimize fit were allowed during the study period and were duplicated in the comparison prosthesis.

Study variables

Laboratory- and community-based health outcomes were identified to quantify differences between the tested interventions. Outcomes were selected based on preliminary data, review of similar studies,[12] the investigators’ experience with similar patients with lower limb amputation, and clinical rationale. Laboratory-based outcomes selected included endurance, perceived exertion, and walking performance. Community-based outcomes included daily step activity and self-reported mobility, fatigue, balance confidence, activity restrictions, and satisfaction. Participants were also asked to indicate and comment on the foot they preferred for performing a variety of low-, moderate-, and high-level activities.

Endurance and perceived exertion.

Endurance was assessed with the Six Minute Walk Test (6MWT). The 6MWT is a submaximal test of aerobic capacity and endurance that exhibits good test-retest reliability in transtibial prosthesis users.[13] This test requires the participant to walk at their fastest possible walking speed for six minutes. The test was conducted with cones separated by 30m in an unobstructed indoor hallway, as recommended in administration guidelines.[14] Encouragement was not provided during the test for either session to standardize the administration protocol.[15] The study variable associated with the 6MWT is distance (m) traveled in the six-minute period.

Perceived exertion following the 6MWT was assessed with the Borg-CR100 Rating of Perceived Exertion (RPE).[16,17] RPE has been used previously to measure exertion after the 6MWT in people with lower limb amputation.[13] The Borg RPE correlates with oxygen consumption in individuals without amputation under select situations.[18] The study variable associated with RPE is the Borg-CR100 score (range of scores is 0–120, higher scores indicate more exertion).

Participants were noted to have experienced a benefit from the XF or the ESF if they demonstrated a clinically-significant change in the 6MWT and/or the Borg CR-100. Participants were noted to have no change on these measures if they did not demonstrate clinically-significant change in either measure. A clinically-significant difference in the 6MWT was defined as a change in distance by greater than 45 meters.[19] A clinically-significant difference in the Borg was defined as a change greater than 10 points.[20]

Walking performance.

Walking performance was assessed using a 4.9m GAITRite System (CIR Systems, Havertown, Pennsylvania). The GAITRite is a pressure-sensitive instrumented walkway that has been used extensively in the scientific literature to measure temporal-spatial parameters of gait across populations, both able-bodied[21] and impaired (including people with lower limb amputation[2225]). It has been validated against gold-standard motion-analysis systems to provide accurate measurement of walking speed and foot placement[26] and has demonstrated good reliability[27] at both self-selected and fast speeds. Data were sampled at 80Hz as participants ambulated over the walkway during the 6MWT. The GAITRite was placed in the middle of the 30m unobstructed hallway to minimize the influence of turns, acceleration, and deceleration on collected gait data. Seven spatiotemporal variables, including average walking speed (m/s), step width (cm), prosthetic and sound side step lengths (cm), and prosthetic and sound side step times (s), were collected with the GAITRite walkway. Definitions for spatiotemporal variables are based on the GAITRite Electronic Walkway Technical Reference Manual[10] with the exception of step width, which was defined as heel-to-heel base of support.

Step activity.

Daily step activity was measured by the StepWatch 3 step activity monitor (SAM, Modus Health LLC, Washington, DC) attached to the prosthesis. The SAM was configured to record the number of steps taken by the wearer in 1-min increments for periods of up to 60 days. The SAM has excellent evidence of measurement reliability and validity across patient populations, including persons with limb loss.[2830] Data from the activity monitor were downloaded to a laptop computer (HP; Palo Alto, CA) at each assessment and were processed according the manufacturer's instructions using the StepWatch 3.4 Software. Step activity on test days was removed from the analysis to mitigate the influence of laboratory performance testing on participants' step activity. The study variable for step activity was mean daily step count (steps/day).

Mobility, fatigue, and balance confidence.

Mobility was measured with the Prosthetic Limb Users Survey of Mobility (PLUS-M) version 1.2, a self-report instrument developed to be a brief, valid, and reliable measure of mobility.[31,32] PLUS-M is specific to measurement of mobility in prosthetic limb users and has been developed with data from over 1300 people with lower limb amputation. Internal consistency is greater than 0.9 and PLUS-M scores correlate with other measures of mobility in hypothesized magnitude and direction.[31] The PLUS-M was administered by a 12-item short form and computerized adaptive test; the most precise score (i.e., the score with the lowest standard error) was used in the analysis. The study variable for self-reported mobility was PLUS-M T-score (range of possible scores is 17.5–76.6, where 50 is the mean of the development sample). Higher scores indicate better mobility.

Fatigue was assessed using the Patient-Reported Outcomes Measurement Information System- Fatigue (PROMIS-F) version 1.0, a self-report questionnaire that measures symptoms and effects of fatigue on respondents’ ability to execute daily activities. PROMIS measures, including PROMIS-F, were developed using rigorous modern measurement techniques and validated in the general United States population and clinical samples.[33] PROMIS-F was administered to participants by a 12-item short form and CAT, and the most precise score (i.e., the score with the lowest standard error) was used in the analysis. The study variable for self-reported fatigue was PROMIS-F T-score (range of possible scores is 29.4–84.0, where 50 is the mean of a development sample representative of the general United States population in gender, age, race, ethnicity, and education[34]). Higher scores indicate more fatigue. Normative PROMIS-F scores in samples with lower limb amputation have been previously reported in the literature.[35]

Balance confidence was assessed with the Activities Specific Balance Confidence Scale (ABC). The ABC is a self-report measure of respondents’ confidence in performing 16 community-based standing and walking activities without falling or feeling unsteady.[36] The ABC has demonstrated good psychometric properties, including retest reliability and construct validity, in samples with lower limb amputation.[37] A revised version of the ABC with a 5-point response scale [38] was used to ease administration and improve scoring. The study variable for balance confidence was the ABC score (range of scores is 0–4, higher scores indicate more balance confidence).

Activity restrictions and satisfaction.

The 19-item revised Trinity Amputation and Prosthesis Experience Scales is a multidimensional health instrument that measures self-reported activity restrictions (TAPES-AR) and satisfaction with the function (TAPES-FUN) and aesthetics (TAPES-AES) of a prosthesis.[39,40] The revised TAPES measures have demonstrated good internal consistency in people with lower limb amputation.[39] A revised scoring system based on subscale average scores, rather than sum scores, was adopted in consultation with the TAPES developers. The study variables for activity restriction was the TAPES-AR score, and the study variable for satisfaction was the TAPES-FUN and TAPES-AES scores (range of scores was 0–2 for each subscale, higher scores indicate more restrictions for the TAPES-AR and more satisfaction for the TAPES-FUN and TAPES-AES).

Prosthetic foot preference.

An ad hoc exit survey was administered to participants to assess which prosthetic foot they preferred overall and which they preferred for use in a number of specific activities. Preference was measured using standardized response options (i.e., XF, ESF, no preference, not applicable). Participants were also asked to provide additional details about their experiences using each prosthesis. Development of a structured exit survey was prompted by spontaneous comments made by initial study participants. The exit survey was added to the study protocol after the study had commenced to more comprehensively document participants’ experiences with each foot. Therefore, exit survey data was collected and is presented on only a subset of sample (19 of 27 participants).

Study protocol

All study procedures were reviewed and approved by University of Washington (approval date: 02/2015) and U.S. Army Medical Research review boards. Informed consent was obtained from all participants prior to their involvement in study activities. Enrollment for the study occurred between 05/2015 and 01/2017. Data collection occurred between 08/2015 and 05/2017.

Screening.

Potential participants were first assessed for eligibility via a telephone screening interview. Interested individuals who met the selection criteria were invited to the laboratory for an in-person screening to verify eligibility. Investigators also inspected each candidate’s residual limb and assessed their willingness to complete study procedures. Eligible individuals completed a self-report survey that included basic demographic (e.g., age, sex) and health questions (e.g., cause of amputation, time since amputation, hours of daily prosthesis use). A research prosthetist assessed each participant’s Medicare Functional Classification Level (“K-level”)[41] via clinical inspection and interview.

Prosthetic fabrication and fitting.

Each participant had two prostheses fabricated by their usual prosthetist. Prostheses were fabricated, fit, and aligned in accordance with good clinical practices. Optimal fit, alignment, and function of each prosthesis was verified by at least one study prosthetist (CM, EH). Participants were administered the socket comfort score[42] (SCS) at each data collection session to confirm equivalent socket fit across prosthetic conditions. A research prosthetist also affixed a SAM to each participant’s prosthetic foot, per the developers’ instructions.[28] Participants used the assigned prosthesis (i.e., XF or ESF) for a period of 1 month and returned for data collection. The other prosthesis was left with study researchers to ensure full time use of the assigned prosthesis.

First data collection session.

Participants returned to the laboratory for testing after 1 month. The SAM was removed and the data downloaded to a laptop computer. Investigators visually reviewed the SAM data and inquired with the participant if any step activity data were missing. Participants then completed a self-report survey hosted on the Assessment CenterSM (Northwestern University, Chicago, IL)[43] and administered on a tablet computer (Apple iPad, Cupertino, CA). The survey included standardized instruments selected to measure participants’ mobility, fatigue, balance confidence, activity restrictions, and satisfaction. Participants were then administered the 6MWT, during which they also walked over the GAITRite walkway. Participants were familiarized with the Borg-CR100 RPE scale prior to the 6MWT and standardized instructions[14] were used in administration. Immediately upon conclusion of the 6MWT, participants reported their exertion using the Borg-CR100 RPE. Following the first data collection session, participants transitioned to the other prosthesis and used it exclusively for at least one month before returning for the second data collection session.

Second data collection session.

All instructions and procedures for the second period of use and data collection session were identical to those described for the first period of use and data collection session. Upon conclusion of the second data collection session, participants were asked to complete the standardized exit survey. Participants were allowed to keep both prostheses at the conclusion of the study.

Data analysis

Visual analyses (e.g., histograms) were used to evaluate distributions of the collected data. Descriptive statistics (e.g., means, standard deviations) were calculated for all measures. Differences between ESF and XF conditions were assessed based on best statistical practices for a crossover analysis.[44] Two-sample t-tests were first conducted to determine whether carryover effects were present. For each variable, the sum of observations (i.e., time, distance, or score, based on the selected variable) for the sequence in which participants first received ESF was compared to the sum of observations for those who first received XF. When no significant carryover effects were observed, two-sample t-tests were conducted to assess the effects of intervention. For each variable, the difference in observations for the sequence in which participants received ESF first was compared to the difference in observations for the sequence in which participants received XF first. Holm-Bonferroni adjustments for multiple comparisons were applied to yield an experiment-wise alpha level of .05.[45] Effect sizes (i.e., Cohen’s d) were computed for all measured outcomes to aid in interpretation of the results.

Results

Participants

Thirty-one people with transtibial amputation enrolled in the study and complete datasets were collected for 30 participants. Three participants completed study protocols, but were not included in the final dataset as their health outcomes data were atypical due to shoulder surgery, significant changes in residual limb volume that affected socket fit, and the death of spouse. One participant did not complete study protocols due to relocation midway through the study (Fig 4).

Data from 27 total participants were analyzed (Table 1). All but one participant were classified by study prosthetists as unlimited community ambulators (K3, n = 16) or active adults (K4, n = 10), which is typical for people who use ESF and XF prostheses.

thumbnail
Table 1. Participant demographics and characteristics (n = 27).

https://doi.org/10.1371/journal.pone.0189652.t001

Assessment of carryover effects

No significant carryover effects were observed between Session 1 and Session 2 (all p>.14).

Laboratory-based outcomes

Endurance and perceived exertion.

Participants walked similar distances (p = .29) during the 6MWT in the ESF and XF prostheses. Following the 6MWT, participants reported greater perceived exertion on the Borg-CR100 scale in the ESF compared to the XF condition, however this difference was not statistically significant (p = .05, Table 2, S1 Fig).

thumbnail
Table 2. Results of clinical performance and self-report measures (n = 27).

https://doi.org/10.1371/journal.pone.0189652.t002

Walking performance.

Participants walked with a significantly longer step length on their sound side in the XF compared to the ESF prosthesis (mean difference = 3 cm, p < .001). Across participants, the measured difference in step length resulted in a more symmetrical step length. Other gait parameters (i.e., walking speed, step width, step time, prosthetic side step length) collected during the 6MWT did not significantly differ between foot conditions (all p>.14, Table 2, S1 Fig).

Community-based outcomes

Step activity.

On average, participants took 198 more steps per day while wearing ESF than while wearing XF, but this difference was not statistically significant (p = .14, Table 2, S1 Fig).

Mobility, fatigue, and balance confidence.

Participants reported better mobility (PLUS-M, p = .001), less fatigue (PROMIS-F, p = .001), and greater balance confidence (ABC, p = .005) in the XF compared to the ESF prosthesis (Table 2, S1 Fig).

Activity restrictions and satisfaction.

Participants reported fewer activity restrictions (TAPES-AR, p = .002) and greater satisfaction with the function (TAPES-FUN, p < .001) of the XF prosthesis compared to ESF prosthesis. There was no difference in aesthetic satisfaction between conditions (TAPES-AES, p = .85, Table 2, S1 Fig).

Prosthetic foot preference

Of the 19 participants that completed the standardized exit interview, 17 preferred the XF overall and two stated that they had no preference between feet. No participants preferred the ESF overall (Table 3). Activities in which the majority of participants reported a preference for the XF included walking on inclines (n = 14), ascending stairs (n = 14), walking quickly (n = 18), traversing uneven terrain (n = 11), carrying a heavy load (n = 13), playing sports (n = 12), and running (n = 15). Activities in which the majority of participants reported no preference between feet included standing up from a chair (n = 12), sitting down in a chair (n = 11), getting in and out of a car (n = 11), and walking when you cannot see your feet (n = 13). There were no activities in which the majority of participants preferred the ESF.

Discussion

The goal of this study was to compare health outcomes of transtibial prosthesis users between ESF and XF prostheses. Results of this study indicate that users experienced significant improvements in most community-based health outcomes in the XF condition. Specifically, participants reported better mobility, balance confidence, and functional satisfaction and less fatigue and activity restrictions. Only one laboratory-based health outcome, sound side step length, was significantly different between foot conditions, with participants taking longer sound side steps in the XF compared to the ESF prosthesis. No significant differences were observed in endurance, rating of perceived exertion, most aspects of walking performance, daily step activity, or aesthetic satisfaction, indicating that participants experienced similar outcomes across foot conditions in these areas. Most study participants preferred the XF prosthesis overall, and particularly preferred it for performing high-level activities, such as walking when carrying a heavy load, playing sports, and running.

While overall results of this study indicate similar or improved performance in the XF relative to the ESF prosthesis, it is important to note that significant differences were based predominantly on self-report measures. Participants reported that they experienced better mobility and functional satisfaction, lower fatigue, and less activity restrictions. Interestingly, participants did not demonstrate significantly improved endurance based on 6MWT distance, significantly improved walking performance as measured by most spatiotemporal metrics, or significantly increased step activity as measured by SAMs. These findings imply people perceived benefits when wearing the XF for community-based activities, but the performance-based measures we chose for this study were unable to detect these perceived differences between feet.

Discrepancies between performance measurement and users’ experiences of outcomes related to ESF has been previously noted,[46] and is likely due to inherent differences in these approaches to health outcomes measurement. Even when assessing a singular construct, it is generally recognized that performance-based and self-report instruments measure different aspects of functioning.[47] Performance-based measures promote objectivity, but are often constrained to a laboratory-based environment and may not reflect ecologically-valid situations or settings. For example, the laboratory-based measures in the current study primarily evaluated the distance and quality of walking over a level surface. While the ability to walk long distances is important to many prosthetic limb users, such activities are not typical in daily life.[48,49] Further, walking on level surfaces may not generalize to the various activities that characterize typical home and community mobility.[50,51] In contrast, self-report measures like the PLUS-M, TAPES-AR, and ABC evaluate a variety of mobility activities beyond simple locomotion, including traversing curbs, slopes, stairs, and uneven terrain, walking while being bumped into by others, running, and participating in sports, hobbies, and vocational activities.[39,52] Laboratory-based performance measures and community-based self-report measures, therefore, provided complementary information about users’ experiences with ESF and XF in this study. Due to inherent differences in these measures, combinations of performance and self-report measures should be used in future prosthetic foot intervention research to more comprehensively assess health outcomes that are important to prosthetic foot users.

Improvements in most community-based measures, but not in laboratory-based walking over a level surface, suggests that XF may improve mobility in real-world or high-level activities. Complex mobility activities, such as those evaluated with community-based self-report measures in this study, may be more affected by prosthetic foot design than level walking, an activity that both XF and ESF are well-designed to perform. Future research is needed to assess the performance of XF and ESF in demanding, high-level mobility activities like jogging and agility tests.[53] Additionally, investigations that use direct measures of performance outside of laboratory settings are needed.

Unlike the other community-based measures used in this study, daily step activity was not significantly different between ESF and XF conditions. While step activity provides an important glimpse into locomotor activities performed by a prosthesis user in their daily life, step count has not been shown to be sensitive to interventions in recent studies that examined a variety of high- and low-activity prosthetic feet.[5456] One possible reason for the lack of sensitivity in step count is that higher mean daily steps is not inherently better. For example, if step length is increased, as in the XF condition in this study, participants may be able to walk the same distance each day using fewer steps. Further, daily step activity is often determined by a person’s work, family, and social priorities and is, therefore, not easily varied due to the design of a prosthesis. Additionally, variations in daily step count due to atypical routine (e.g., vacation or unusual work schedule), can obscure the effects of a prosthetic foot on daily activity. More selective analysis of step activity data, guided by participants’ report of unusual activity, may provide additional insight into the relative effects of XF and ESF on community-based activity.

Sound-side step length in the current study was significantly increased in the XF compared to the ESF prosthesis (mean difference = 3.0 cm). A similar increase in sound-side step length (mean difference = 3.3 cm) was also observed for the XF in a previous cross-sectional study that assessed ESF and XF users’ walking performance.[11] Increased XF step length is further supported by participant statements in the exit interview that indicated users experienced a feeling of “more propulsion” and “smoother transition” in the XF condition. In both studies, changes in sound side step length normalized step length symmetry between the prosthetic and sound sides in the XF compared to the ESF. Improved symmetry is clinically important because it is hypothesized to reduce secondary physical conditions (e.g., osteoarthritis) common in long-term prosthesis users.[5759]

Sound side step lengths likely increased in the XF condition due to its unique keel properties (e.g., shape and stiffness). XF keels are longer and stiffer then ESF keels, which allow more energy to be stored and returned as the keel deflects and recoils during gait. Previous research in early ESF found that the keel of the Flex Foot, which like the XF in this study had extended and posteriorly-attached keel, facilitated second rocker motion and decreased sound limb loading forces compared to other prosthetic feet (e.g., solid ankle cushion heel, SACH).[60,61] Similarly, investigation into the relationship between prosthetic keel flexibility and gait outcomes demonstrated that increased keel stiffness improved symmetry due to longer sound side steps and reduced sound side loading.[62] Thus, the increased sound-side step length observed in the present study may also decrease sound side loading due to the XF’s extended and stiff keel design. Additional research is required to better understand how the mechanical properties of prosthetic feet, including the deflection of the keel spring and the timing of the recoil, contribute to sound side kinetic outcomes and changes in users’ long-term physical health.

Measurements of endurance (6MWT) and perceived exertion (Borg-CR100) in this study were not found to significantly differ between prosthetic foot conditions. While it was hypothesized that individual participants would walk farther during and report reduced perceived exertion after the 6MWT in the XF condition, none of the participants in this study experienced improvements on both measures that exceeded estimates of detectable change reported in the literature (6MWT: 45m[19], Borg: 10 points[20]). However, many participants either walked farther or reported reduced exertion in the XF. Specifically, almost half (48%) of participants experienced a clinically-significant benefit in either 6MWT distance or Borg RPE while walking with an XF compared to approximately one-fifth (19%) of participants who experienced a clinically-significant benefit in the ESF condition. This finding suggests that almost 50% of people with transtibial amputation experience a benefit in either endurance or exertion in long-distance walking with the XF. Previous investigators have not found significant differences in 6MWT distance when comparing prosthetic feet.[55,56] However, these studies did not include or present data from the Borg to assess the tradeoff between endurance and exertion. Future prosthetic foot intervention studies should administer the Borg immediately following the 6MWT to assess potential tradeoffs between participants’ walking performance and perceived exertion.

Strengths and limitations

Strengths of this study include the relatively large sample size of 27 participants. Prosthetic foot comparative effectiveness studies are typically much smaller, including between 3–16 people in each study.[63] In addition, participants crossed over between interventions, so each person acted as their own control. Further, data were collected longitudinally, which allowed participants one month to accommodate to each prosthetic foot condition. The extended accommodation period also allowed for the collection of community-based outcome measures to complement laboratory-based assessment of XF and ESF. Qualitative feedback in the form of exit interviews was also collected to provide context for the other measured health outcomes. Lastly, prostheses used in the study were standardized between prosthetic foot conditions and optimized by clinicians who have extensive experience with ESF fittings and have the training required for XF fittings.

Limitations of this study include the extent to which the results can be generalized to the overall population of people with lower limb amputation. While the results of this study may be generalized to people with unilateral transtibial amputation who are deemed to be community ambulators or active adults, the effects of XF on health outcomes for people with bilateral limb amputation, higher levels (e.g., transfemoral) of amputation, and lower mobility levels were not studied. Future research should assess health outcomes related to XF use in these patient groups. In addition, there is potential for bias in participant report, both in community-based self-report measures and in qualitative exit interviews. Due to the differences in overall design between XF and ESF prostheses (e.g., the extended strut and the posterior attachment of the XF), users were not blinded to interventions. Users may have reported better outcomes in the XF condition due to its novelty. Nonetheless, results for both XF and ESF conditions were similar to or better than average for measures with published transtibial prosthesis user norms (i.e., PLUS-M,[64] ABC,[65] and PROMIS-F[35]), indicating that participants in the study reported good outcomes relative to established norms in both feet. Lastly, investigators were not blinded to the intervention. Standardized methods of data collection and analysis were used to mitigate possible investigator biases, and all investigators verified they had no financial conflicts of interest related to the study.

Conclusions

Compared to ESF, XF improved community-based health outcomes, including perceived mobility, balance confidence, fatigue, activity restrictions, and functional satisfaction, in community ambulators and active adults with unilateral transtibial amputation. Further, sound side step length increased in the XF condition, which may convey short- and long-term kinetic benefits for the sound limb. Importantly, participants in this study largely preferred XF over the ESF for daily activities, especially high-level activities like running and sports. Prosthetic limb users demonstrated similar performance on laboratory-based measures of endurance, walking performance, and step activity between foot conditions. Overall, XF are a promising advancement in prosthetic foot technology for community ambulators or active adults with unilateral transtibial amputation, although additional research is warranted to assess their effectiveness for other patient populations with lower limb amputation.

Supporting information

S1 Fig. Results figures.

Graphical depiction of endurance (6MWT), perceived exertion (Borg-CR100), spatiotemporal walking performance, and community-based outcome measure results.

https://doi.org/10.1371/journal.pone.0189652.s001

(DOCX)

Acknowledgments

The authors wish to acknowledge Angelina Boulicault and Elen Feuerriegel, PhD, for assistance with data collection, Greg Davidson, CPO, John Shaffer, CPO, and Ryan Blanck, CPO, for donation of fabrication time and materials, and Ossur ehf Iceland Research and Development for donation of prosthetic components.

References

  1. 1. Versluys R, Beyl P, Van Damme M, Desomer A, Van Ham R, Lefeber D. Prosthetic feet: state-of-the-art review and the importance of mimicking human ankle-foot biomechanics. Disabil Rehabil Assist Technol. 2009;4(2):65–75. pmid:19253096
  2. 2. Gailey R. Functional value of prosthetic foot/ankle systems to the amputee. J Prostet Orthot. 2005;17(4):S39–S41.
  3. 3. Brown MB, Millard-Stafford ML, Allison AR. Running-specific prostheses permit energy cost similar to nonamputees. Med Sci Sports Exerc. 2009;41(5):1080–7. pmid:19346979
  4. 4. Linendoll K. Össur’s Cheetah Goes for Paralympic Gold ESPN.com 2012 [Available from: http://espn.go.com/blog/playbook/tech/post/_/id/2047/ossurs-flex-foot-cheetah-goes-for-gold-in-paralympics.
  5. 5. Shaw A. Pistorius, 25, Is First Double-Amputee Sprinter to Compete in Olympic Games: ABC News; 2012 [Available from: http://abcnews.go.com/Sports/oscar-pistorius-makes-history-double-amputee-sprinter-compete/story?id=16929845.
  6. 6. Webster JB, Levy CE, Bryant PR, Prusakowski PE. Sports and recreation for persons with limb deficiency. Arch Phys Med Rehabil. 2001;82(3 Suppl 1):S38–44.
  7. 7. Matthews D, Sukeik M, Haddad F. Return to sport following amputation. J Sports Med Phys Fitness. 2014;54(4):481–6. pmid:25034549
  8. 8. Fergason JR, Boone DA. Custom design in lower limb prosthetics for athletic activity. Phys Med Rehabil Clin N Am. 2000;11(3):681–99. pmid:10989486
  9. 9. Dillingham TR, Pezzin LE, MacKenzie EJ, Burgess AR. Use and satisfaction with prosthetic devices among persons with trauma-related amputations: a long-term outcome study. Am J Phys Med Rehabil. 2001;80(8):563–71. pmid:11475475
  10. 10. Klute GK, Kantor C, Darrouzet C, Wild H, Wilkinson S, Iveljic S, et al. Lower-limb amputee needs assessment using multistakeholder focus-group approach. J Rehabil Res Dev. 2009;46(3):293–304. pmid:19675983
  11. 11. Hafner B, Halsne E, Morgan S, Davidson G. Functional outcomes in people with transtibial amputation using crossover and energy-storing prosthetic feet: a pilot study. J Prosthet Orthot. 2017; Publish Ahead of Print.
  12. 12. van der Linde H, Hofstad CJ, Geurts AC, Postema K, Geertzen JH, van Limbeek J. A systematic literature review of the effect of different prosthetic components on human functioning with a lower-limb prosthesis. J Rehabil Res Dev. 2004;41(4):555–70. pmid:15558384
  13. 13. Lin SJ, Bose NH. Six-minute walk test in persons with transtibial amputation. Arch Phys Med Rehabil. 2008;89(12):2354–9. pmid:18976979
  14. 14. American Thoracic Society. ATS statement: guidelines for the six-minute walk test. Am J Respir Crit Care Med. 2002;166(1):111–7. pmid:12091180
  15. 15. Guyatt GH, Pugsley SO, Sullivan MJ, Thompson PJ, Berman L, Jones NL, et al. Effect of encouragement on walking test performance. Thorax. 1984;39(11):818–22. pmid:6505988
  16. 16. Borg E, Borg G. A comparison of AME and CR100 for scaling perceived exertion. Acta Psychol. 2002;109(2):157–75.
  17. 17. Borg GA. Borg’s Rating of Perceived Exertion and Pain Scales. Champaign, IL: Human Kinetics; 1998.
  18. 18. Chen MJ, Fan X, Moe ST. Criterion-related validity of the Borg ratings of perceived exertion scale in healthy individuals: a meta-analysis. J Sports Sci. 2002;20(11):873–99. pmid:12430990
  19. 19. Resnik L, Borgia M. Reliability of outcome measures for people with lower-limb amputations: distinguishing true change from statistical error. Phys Ther. 2011;91(4):555–65. pmid:21310896
  20. 20. Ries AL. Minimally clinically important difference for the UCSD Shortness of Breath Questionnaire, Borg Scale, and Visual Analog Scale. COPD. 2005;2(1):105–10. pmid:17136970
  21. 21. Beauchet O, Allali G, Annweiler C, Bridenbaugh S, Assal F, Kressig RW, et al. Gait variability among healthy adults: low and high stride-to-stride variability are both a reflection of gait stability. Gerontol. 2009;55(6):702–6.
  22. 22. Hordacre B, Barr C, Crotty M. Use of an activity monitor and GPS device to assess community activity and participation in transtibial amputees. Sensors. 2014;14(4):5845–59. pmid:24670721
  23. 23. Fridman A, Ona I, Isakov E. The influence of prosthetic foot alignment on trans-tibial amputee gait. Prosthet Orthot Int. 2003;27(1):17–22. pmid:12812324
  24. 24. Isakov E, Keren O, Benjuya N. Trans-tibial amputee gait: time-distance parameters and EMG activity. Prosthet Orthot Int. 2000;24(3):216–20. pmid:11195356
  25. 25. Highsmith MJ, Schulz BW, Hart-Hughes S, Latlief GA, Phillips SL. Differences in the spatiotemporal parameters of transtibial and transfemoral amputee gait. J Prosthet Orthot. 2010;22(1):26–30.
  26. 26. Webster KE, Wittwer JE, Feller JA. Validity of the GAITRite walkway system for the measurement of averaged and individual step parameters of gait. Gait Posture. 2005;22(4):317–21. pmid:16274913
  27. 27. van Uden CJ, Besser MP. Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite). BMC Musculoskelet Disord. 2004;5:13. pmid:15147583
  28. 28. Coleman KL, Smith DG, Boone DA, Joseph AW, del Aguila MA. Step activity monitor: long-term, continuous recording of ambulatory function. J Rehabil Res Dev. 1999;36(1):8–18. pmid:10659890
  29. 29. Godfrey A, Conway R, Meagher D, Olaighin G. Direct measurement of human movement by accelerometry. Med Eng Phys. 2008;30(10):1364–86. pmid:18996729
  30. 30. Bassett DR, John D. Use of pedometers and accelerometers in clinical populations: validity and reliability issues. Phys Ther Rev. 2010;15(3):135–42.
  31. 31. Hafner BJ, Gaunaurd IA, Morgan SJ, Amtmann D, Salem R, Gailey RS. Construct Validity of the Prosthetic Limb Users Survey of Mobility (PLUS-M) in Adults With Lower Limb Amputation. Arch Phys Med Rehabil. 2017;98(2):277–85. pmid:27590443
  32. 32. Hafner BJ, Morgan SJ, Askew RL, Salem R. Psychometric evaluation of self-report outcome measures for prosthetic applications. J Rehabil Res Dev. 2016;53(6):797–812. pmid:28273329
  33. 33. Cella D, Riley W, Stone A, Rothrock N, Reeve B, Yount S, et al. The Patient-Reported Outcomes Measurement Information System (PROMIS) developed and tested its first wave of adult self-reported health outcome item banks: 2005–2008. J Clin Epidemiol. 2010;63(11):1179–94. pmid:20685078
  34. 34. Liu H, Cella D, Gershon R, Shen J, Morales LS, Riley W, et al. Representativeness of the Patient-Reported Outcomes Measurement Information System Internet panel. J Clin Epidemiol. 2010;63(11):1169–78. pmid:20688473
  35. 35. Amtmann D, Morgan SJ, Kim J, Hafner BJ. Health-related profiles of people with lower limb loss. Arch Phys Med Rehabil. 2015;96(8):1474–83. pmid:25917819
  36. 36. Powell LE, Myers AM. The Activities-specific Balance Confidence (ABC) Scale. J Gerontol A Biol Sci Med Sci. 1995;50a(1):M28–34. pmid:7814786
  37. 37. Miller WC, Deathe AB, Speechley M. Psychometric properties of the Activities-specific Balance Confidence scale among individuals with a lower-limb amputation. Arch Phys Med Rehabil. 2003;84(5):656–61. pmid:12736877
  38. 38. Sakakibara BM, Miller WC, Backman CL. Rasch analyses of the Activities-specific Balance Confidence Scale with individuals 50 years and older with lower-limb amputations. Arch Phys Med Rehabil. 2011;92(8):1257–63. pmid:21704978
  39. 39. Gallagher P, Franchignoni F, Giordano A, MacLachlan M. Trinity amputation and prosthesis experience scales: a psychometric assessment using classical test theory and rasch analysis. Am J Phys Med Rehabil. 2010;89(6):487–96. pmid:20489393
  40. 40. Gallagher P, Maclachlan M. The Trinity Amputation and Prosthesis Experience Scales and quality of life in people with lower-limb amputation. Arch Phys Med Rehabil. 2004;85(5):730–6. pmid:15129396
  41. 41. Medicare region C durable medical equipment prosthetics orthotic supplier (DMEPOS) manual. 2005.
  42. 42. Hanspal RS, Fisher K, Nieveen R. Prosthetic socket fit comfort score. Disabil Rehabil. 2003;25(22):1278–80. pmid:14617445
  43. 43. Gershon R, Rothrock NE, Hanrahan RT, Jansky LJ, Harniss M, Riley W. The development of a clinical outcomes survey research application: Assessment Center(SM). Qual Life Res. 2010;19(5):677–85. pmid:20306332
  44. 44. Wellek S, Blettner M. On the proper use of the crossover design in clinical trials: part 18 of a series on evaluation of scientific publications. Dtsch Arztebl Int. 2012;109(15):276–81. pmid:22567063
  45. 45. Holm S. A Simple Sequentially Rejective Multiple Test Procedure. Scand J Stat. 1979;6(2):65–70.
  46. 46. Hafner BJ, Sanders JE, Czerniecki J, Fergason J. Energy storage and return prostheses: does patient perception correlate with biomechanical analysis? Clin Biomech. 2002;17(5):325–44.
  47. 47. Coman L, Richardson J. Relationship between self-report and performance measures of function: a systematic review. Can J Aging. 2006;25(3):253–70. pmid:17001588
  48. 48. Orendurff MS, Schoen JA, Bernatz GC, Segal AD, Klute GK. How humans walk: bout duration, steps per bout, and rest duration. J Rehabil Res Dev. 2008;45(7):1077–89. pmid:19165696
  49. 49. Klute GK, Berge JS, Orendurff MS, Williams RM, Czerniecki JM. Prosthetic intervention effects on activity of lower-extremity amputees. Arch Phys Med Rehabil. 2006;87(5):717–22. pmid:16635636
  50. 50. Patla AE, Shumway-Cook A. Dimensions of Mobility: Defining the Complexity and Difficulty Associated with Community Mobility. J Aging Phys Act. 1999;7(1):7–19.
  51. 51. Hafner BJ, Morgan SJ, Abrahamson DC, Amtmann D. Characterizing mobility from the prosthetic limb user's perspective: Use of focus groups to guide development of the Prosthetic Limb Users Survey of Mobility. Prosthet Orthot Int. 2016;40(5):582–90. pmid:25944625
  52. 52. Amtmann D, Abrahamson D, Morgan S, Salem R, Askew R, Gailey R, et al. The PLUS-M: Item Bank Of Mobility For Prosthetic Limb Users. Proceedings of the ISOQOL 20th Annual Conference, Berlin, Germany, October 15–18, 2014.
  53. 53. Gailey RS, Gaunaurd IA, Raya MA, Roach KE, Linberg AA, Campbell SM, et al. Development and reliability testing of the Comprehensive High-Level Activity Mobility Predictor (CHAMP) in male servicemembers with traumatic lower-limb loss. J Rehabil Res Dev. 2013;50(7):905–18. pmid:24301428
  54. 54. Raschke SU, Orendurff MS, Mattie JL, Kenyon DE, Jones OY, Moe D, et al. Biomechanical characteristics, patient preference and activity level with different prosthetic feet: a randomized double blind trial with laboratory and community testing. J Biomech. 2015;48(1):146–52. pmid:25480541
  55. 55. Wurdeman SR, Schmid KK, Myers SA, Jacobsen AL, Stergiou N. Step Activity and 6-Minute Walk Test Outcomes When Wearing Low-Activity or High-Activity Prosthetic Feet. Am J Phys Med Rehabil. 2017;96(5):294–300. pmid:27584137
  56. 56. Gailey RS, Gaunaurd I, Agrawal V, Finnieston A, O'Toole C, Tolchin R. Application of self-report and performance-based outcome measures to determine functional differences between four categories of prosthetic feet. J Rehabil Res Dev. 2012;49(4):597–612. pmid:22773262
  57. 57. Gailey R, Allen K, Castles J, Kucharik J, Roeder M. Review of secondary physical conditions associated with lower-limb amputation and long-term prosthesis use. J Rehabil Res Dev. 2008;45(1):15–29. pmid:18566923
  58. 58. Norvell DC, Czerniecki JM, Reiber GE, Maynard C, Pecoraro JA, Weiss NS. The prevalence of knee pain and symptomatic knee osteoarthritis among veteran traumatic amputees and nonamputees. Arch Phys Med Rehabil. 2005;86(3):487–93. pmid:15759233
  59. 59. Struyf PA, van Heugten CM, Hitters MW, Smeets RJ. The prevalence of osteoarthritis of the intact hip and knee among traumatic leg amputees. Arch Phys Med Rehabil. 2009;90(3):440–6. pmid:19254609
  60. 60. Powers CM, Torburn L, Perry J, Ayyappa E. Influence of prosthetic foot design on sound limb loading in adults with unilateral below-knee amputations. Arch Phys Med Rehabil. 1994;75(7):825–9. pmid:8024435
  61. 61. Snyder RD, Powers CM, Fontaine C, Perry J. The effect of five prosthetic feet on the gait and loading of the sound limb in dysvascular below-knee amputees. J Rehabil Res Dev. 1995;32(4):309–15. pmid:8770795
  62. 62. Klodd E, Hansen A, Fatone S, Edwards M. Effects of prosthetic foot forefoot flexibility on gait of unilateral transtibial prosthesis users. J Rehabil Res Dev. 2010;47(9):899–910. pmid:21174254
  63. 63. Hofstad C, Linde H, Limbeek J, Postema K. Prescription of prosthetic ankle-foot mechanisms after lower limb amputation. Cochrane Database Syst Rev. 2004(1):Cd003978. pmid:14974050
  64. 64. Prosthetic Limb Users Survey of Mobility (PLUS-M™) Version 1.2 Short Forms Users Guide. 2014. http://www.plus-m.org/. Accessed on [July 20, 2017].
  65. 65. Hafner B, Amtmann D, Abrahamson D, Morgan S, Kajlich A, Salem R. Normative PEQ-MS and ABC scores among persons with lower limb loss. American Academy of Orthotists & Prosthetists (AAOP) 39th Annual Meeting and Scientific Symposium, Orlando, FL, February 20–23, 2013.