Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Does stroke volume variation predict fluid responsiveness in children: A systematic review and meta-analysis

  • Ling Yi ,

    Contributed equally to this work with: Ling Yi, Zhongqiang Liu

    Affiliations National Office for Maternal and Child Health Surveillance of China, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China, Key Laboratory of Obstetric & Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, Sichuan University, Chengdu, Sichuan, China

  • Zhongqiang Liu ,

    Contributed equally to this work with: Ling Yi, Zhongqiang Liu

    Affiliations Key Laboratory of Obstetric & Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, Sichuan University, Chengdu, Sichuan, China, Department of Pediatric Intensive Care Unit, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China

  • Lina Qiao,

    Affiliations Key Laboratory of Obstetric & Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, Sichuan University, Chengdu, Sichuan, China, Department of Pediatric Intensive Care Unit, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China

  • Chaomin Wan ,

    wcm0220@sina.com (CW); Mudz@scu.edu.cn (DM)

    Affiliations Key Laboratory of Obstetric & Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, Sichuan University, Chengdu, Sichuan, China, Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China

  • Dezhi Mu

    wcm0220@sina.com (CW); Mudz@scu.edu.cn (DM)

    Affiliations Key Laboratory of Obstetric & Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, Sichuan University, Chengdu, Sichuan, China, Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China

Abstract

Objective

Stroke volume variation (SVV) is a reliable predictor of fluid responsiveness in adult patients. However, the predictive value of SVV is uncertain in pediatric patients. We performed the first systematic meta-analysis to evaluate the diagnostic value of SVV in predicting fluid responsiveness in children.

Methods

PUBMED, EMBASE, and Cochrane Central Register of Controlled Trials were searched up to December 2016. Original studies assessing the diagnostic accuracy of SVV in predicting fluid responsiveness in children were considered to be eligible. A random-effects model was used to calculate pooled values of sensitivity, specificity and diagnostic odds ratio with 95% CI. The summary receiver operating characteristic curve was estimated and area under the curve was calculated. Quality of the studies was assessed with the QUADAS-2 tool.

Results

Six studies with a total of 279 fluid boluses in 224 children were included. The analysis demonstrated a pooled sensitivity of 0.68 (95% CI,0.59–0.76), pooled specificity of 0.65 (95% CI, 0.57–0.73), pooled diagnostic odds ratio of 8.24 (95% CI, 2.58–26.30), and the summary area under the summary receiver operating characteristic curve of 0.81. However, significant inter-study heterogeneity was found (p<0.05, I2 = 61.3%), likely due to small sample size and diverse study characteristics.

Conclusions

Current evidence suggests that SVV was of diagnostic value in predicting fluid responsiveness in children under mechanical ventilation. Given the high heterogeneity of published data, further studies are needed to confirm the diagnostic accuracy of SVV in predicting fluid responsiveness in pediatric patients.

Introduction

Fluid therapy is the key intervention to improve tissue perfusion and oxygenation for critically ill and perioperative patients [13]. Both inadequate and excessive fluid infusion can lead to deleterious outcome for the patient [4, 5]. Thus, assessment of fluid responsiveness is essential to guide fluid resuscitation and optimize preload in perioperative medicine and critical care. Static measures of preload such as central venous pressure (CVP) and pulmonary artery wedge pressure (PAWP) were found to have poor predictive value in predicting fluid responsiveness [68]. Dynamic indices have emerged as promising predictors in recent years, and have been proven to predict fluid responsiveness far better than static measures [911]. Stroke volume variation (SVV) is one of the most widely used dynamic indices of fluid responsiveness in patients undergoing mechanical ventilation. SVV has been consistently shown to be reliable predictor of fluid responsiveness in adults. Zhang et al [12] reported that SVV was of diagnostic value for fluid responsiveness in adult patients ventilated with tidal volume greater than 8 ml/kg in operating room or intensive care unit. However, in the pediatric population, the predictive value of SVV remains relatively underexplored and the available results are controversial [1315]. We hypothesised that SVV could be of predictive value in predicting fluid responsiveness in children. To test this hypothesis, we performed a systematic review and meta-analysis to summarize available evidence about the diagnostic accuracy of SVV in predicting fluid responsiveness in pediatric patients.

Materials and methods

This systematic review and meta-analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement (PRISMA) as shown in S1 File [16].

Search strategy

Databases of PubMed, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) were searched for relevant publications with the following Medical Subject Headings and search terms: “fluid or volume or preload responsiveness”, “fluid or preload challenge”, “fluid therapy or management”, “stroke volume variation”. The initial search was conducted in August 2016 without language restrictions. The search was updated in December 2016 but did not identify any additional studies for inclusion. The search was conducted separately by two investigators (Z. L. and L.Y.).

Study selection

The titles/abstracts for all articles from the search were reviewed, and full-text articles from potentially relevant abstracts were retrieved for assessment of eligibility. The bibliographies of all relevant articles were reviewed manually to identify additional relevant articles. Studies were included if the following criteria were fulfilled: (1) Studies investigated the ability of SVV to predict fluid responsiveness. (2) Studies involved pediatric subjects (age<18 years). (3) Data were available to calculate sensitivity, specificity. If raw data were not published but the study was otherwise eligible for inclusion, authors were contacted to obtain additional information.

Data extraction

Data from all included studies were abstracted independently by two investigators (Z. L. and L.Y.) into a spreadsheet, with disagreement resolved by consensus. The following data were extracted from each included study: (1) characteristics of study (year of publication, study design, clinical setting), (2) characteristics of trial participants (number of patients, number of fluid bolus, age), (3) methods used to determine fluid responsiveness (monitoring device, fluid bolus type, tidal volume, definition of fluid responsiveness), (4) variables tested (cutoff value, sensitivity, specificity, the area under the receiver operating characteristic curve (AUROC)).

Statistical analysis

A fluid bolus was employed as statistical unit as multiple fluid boluses were used in some patients. From the studies included, we extracted the numbers of fluid boluses with a true-positive, false-positive, true-negative, false-negative test result either directly or through recalculation. Sensitivity, specificity and diagnostic odds ratios (DOR) together with 95% CI for included studies were extracted or calculated based on the reconstructive contingency table. A random-effects model was used to calculate pooled values of sensitivity, specificity and DOR with 95% CI. A summary receiver operating characteristic (SROC) was constructed, and the AUROC was calculated. Statistical heterogeneity between studies was assessed using Cochran-Q and I2 tests [17]. Values of p<0.1 or I2>50% were considered to be statistically significant. Deek's Funnel Plot Asymmetry Test was applied to determine the presence of publication bias [18]. Meta-Disc (version 1.4) software was used for data analysis [19]. Subgroup analysis was performed according to the monitoring device the study used (non-invasive monitoring or invasive monitoring), and the type of patient population (postoperative patients or PICU patients).

Results

Study flow

The flow chart of the study selection is illustrated in Fig 1. A total of 827 studies were identified after an initial search. Of them, 789 were excluded after title and abstract review. Full text review of the 38 potentially eligible articles was carried out and resulted in 32 articles being excluded. Reasons for exclusion are detailed in S2 File. Consequently, six studies were ultimately included in our analysis [13, 14, 2023].

Study characteristics

The characteristics of the individual studies are presented in Table 1. All of the studies were published from 2012 to 2015. Totally 279 fluid boluses were given in 224 children, as two studies used multiple fluid boluses in some patients [13, 20]. In the majority of studies, the patients were mechanically ventilated with tidal volumes of 10 ml/kg. Four studies used colloids as fluid bolus, one study used crystalloid, and one study did not report type of fluid given. Four studies were performed in the operating room during congenital heart surgery or craniosynostosis repair [14, 2123], and two studies were performed in the PICU [13, 20]. SVV was tested by non-invasive measures such as NICOM (non-invasive cardiac output monitor) and USCOM (ultrasonic cardiac output monitor) in four studies, whereas two studies used invasive measures including PiCCO (pulse index continuous cardiac output) and Mostcare. In the majority of studies, fluid responsiveness was defined as change in stroke volume index (SVI) of at least 15%, except one study used a threshold of 10% [20]. The quality of the included studies were assessed by Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) available in Table 2 [24].

thumbnail
Table 2. Quality assessment of included diagnostic accuracy studies using QUADAS-2.

https://doi.org/10.1371/journal.pone.0177590.t002

Quantitative data synthesis

Study data and individual diagnostic estimates are summarized in Table 3. Overall, 47% of the patients included in this review responded to fluid bolus. Cutoff values of SVV varied across studies, ranging from 10% to 22%. The AUROC of individual studies ranged from 0.51 to 0.89. There was significant heterogeneity between the included studies, the I2 for sensitivity, specificity and DOR were 64.6, 77.0 and 61.3, respectively. The pooled sensitivity, specificity and DOR from all six studies were 0.68 (95% CI, 0.59–0.76), 0.65 (95% CI, 0.57–0.73) and 8.24 (95% CI, 2.58–26.30) respectively (Fig 2). Fig 3 presents the receiver operator characteristic (ROC) scatter plot displaying the results of sensitivity and specificity for individual studies in the ROC space. A summary AUROC of 0.81 was obtained. There was evidence of small study effects (Deek's Funnel Plot Asymmetry Test, p = 0.04) (S1 Fig). In the subgroup analysis, summary AUROC for non-invasive monitoring studies and postoperative patients studies were 0.87 and 0.85 respectively (Table 4).

thumbnail
Fig 2. Sensitivity, specificity and diagnostic odds ratio of stroke volume variation in predicting fluid responsiveness in children assessed by forest plots.

The point estimates of sensitivity, specificity and diagnostic odds ratio for each study are shown as solid circles.

https://doi.org/10.1371/journal.pone.0177590.g002

thumbnail
Fig 3. Summary receiver operating characteristic curve of stroke volume variation in predicting fluid responsiveness in children.

Solid circles represent each study included in the meta-analysis.

https://doi.org/10.1371/journal.pone.0177590.g003

Discussion

SVV has been demonstrated to be a reliable predictor of fluid responsiveness in adult patients [12]. However, few studies have addressed the reliability of SVV to predict fluid responsiveness in children. This is the first meta-analysis to examine the ability of SVV to predict the response to volume expansion in pediatric patients. We found six studies with a combined total of 224 patients. The results of meta-analysis showed a pooled sensitivity of 0.68, specificity of 0.65, and a summary AUROC of 0.81. A diagnostic tool with an AUROC of 0.81 is considered to have good diagnostic accuracy. Our results confirmed the diagnostic value of SVV in predicting fluid responsiveness in children under mechanical ventilation. However, high heterogeneity was found between studies, possibly due to small sample size and differences among monitoring devices, the fluid bolus was administered, and also to different patient characteristics.

In critically ill children, especially infants and neonates, adequate fluid resuscitation is a particular challenge for the pediatrician since fluid homeostasis is maintained in a narrow range and physiological compensation of both hypervolaemia and hypovolaemia is limited. Based on the Frank-Starling mechanism, the relationship between preload and stroke volume is curvilinear instead of linear. An increase in stroke volume will be induced by an increase in preload only if the ventricle operates on the ascending portion of the curve [25, 26]. Therefore, it is of great importance to assess each patient’s position on the Frank-Starling curve in order to optimize cardiac preload and avoid fluid overload. Static markers of cardiac preload were found to have poor predictive value of fluid responsiveness. To overcome the limitations of static indices, dynamic parameters have been introduced in clinical practice. Numerous dynamic parameters such as pulse pressure variation (PPV), systolic pressure variation (SPV), respiratory variation in aortic blood flow peak velocity (ΔVPeak) and Plethysmograph variability index (PVI) were investigated for prediction of fluid responsiveness in children [15]. There is no consensus on their predictive value in children except ΔVPeak [27].

In recent years, many investigations have been carried out to explore the SVV diagnostic accuracy in predicting fluid responsiveness. Numerous studies have demonstrated that SVV can predict fluid responsiveness reliably in adults [2830]. A meta-analysis reported that SVV was an accurate predictor of fluid responsiveness in adult patients, with pooled sensitivity of 0.81, specificity of 0.80, and a summary AUROC of 0.93 [12]. The findings of our meta-analysis showed that SVV also have ability to predict fluid responsiveness in children, but the predictive value was not as encouraging as reported in adult patients. We speculated that it may be explained by the physiological differences between children and adult subjects, such as heart rate, chest wall compliance and vascular elasticity, all of which may influence SVV in a different way compared with adults.

Many studies demonstrated that tidal volume was an important factor that influences the predictive value of dynamic parameters. De Backer et al [31] reported that PPV can effectively predict fluid responsiveness in patients under mechanical ventilation only when tidal volume is at least 8 ml/kg. Suehiro et al [32] found that SVV was a reliable predictor of fluid responsiveness in patients undergoing one-lung ventilation provided with tidal volume of 8 ml/kg, while SVV was of no predictive value ventilated at 6 ml/kg. In our meta-analysis, three studies enrolled children mechanically ventilated with tidal volume of 10 ml/kg, the predictive value of SVV was positive in two studies. However, Lee et al [23] reported that SVV did not predict fluid responsiveness in pediatric patients during cardiac surgery ventilated with tidal volumes of 10 ml/kg. Furthermore, it was reported recently that the predictive value of dynamic parameters may be influenced by other settings of mechanical ventilation besides tidal volume in children. Kang et al [33] studied the influence of different peak inspiratory pressure (PIP) on SVV in pediatric cardiac surgery patients, and the result showed that SVV was affected by different levels of PIP in same patient and under same volume status. In consideration of the differences between the physiology in children and adult patients, further studies are needed to explore the optimal tidal volume and other parameters of mechanical ventilation for children.

The pulmonary artery catheter using the thermodilution technique has long been regarded as the gold standard approach for cardiac output monitoring. However, some studies showed that the usage of pulmonary artery catheter may cause complications associated with the insertion and may be related to increased risk in mortality [34, 35]. Alternative monitoring techniques currently available include esophageal Doppler technique (such as USCOM), transoesophageal echocardiography, thoracic electrical bioimpedance devices, pulse contour analysis (such as PiCCO and Mostcare), and bioreactance devices (such as NICOM) [34, 36, 37]. NICOM and USCOM were non-invasive monitoring measures which avoid the potential complications of pulmonary artery catheter insertion and maintenance. Several studies have shown that cardiac output measured by USCOM / NICOM had good accuracy compared with those obtained by the standard thermodilution-based techniques [3841]. Monitoring devices used in the studies were diverse in our analysis, one study using USCOM, one study using PiCCO, one study using Mostcare, three studies using NICOM. Subgroup analysis results showed that SVV with non-invasive monitoring seems to have good value of prediction for fluid responsiveness in pediatric patients. Considering the limited number of studies using invasive monitoring involved in our analysis, more studies are needed to evaluate the predictive value of SVV monitoring with invasive devices.

Assessment and monitoring of fluid status is of great importance for both critically ill patients and perioperative patients to maintain hemodynamic stability. Zhang et al [12] reported that SVV was of diagnostic value for fluid responsiveness both in operating room and intensive care unit, with higher predictive value in the intensive care unit. In our subgroup analysis, the subgroup of postoperative patients appears to have higher value of prediction for fluid responsiveness. With respect to PICU patients involved in our analysis, only two sets of data were available, no definitive conclusion can be drawn in this subgroup of patients.

In our analysis, pediatric patients with a wide age range were enrolled in the studies, some included children younger than 5 years, and some included subjects in their late teens. The cardiovascular physiology changes remarkably from the neonatal period to one year of age, with minor changes thereafter [42, 43]. Myocardium is less responsive to preload and vulnerable to overfilling for newborns [44]. There are dramatic changes in arterial compliance and aortic characteristic impedance from newborns to teenager [45, 46]. Vergnaud et al [22] demonstrated that SVV reliably predicted fluid responsiveness only in children aged more than 3 years old, while AUROC was 0.57 in younger children. It is difficult to interpret the validity of summarized results from subjects of diverse age in our meta-analysis.

Limitations

Several limitations should be considered when assessing the clinical relevance of our study results. Firstly, our analysis included only six studies with a relatively small sample size, among which the study implemented by Saxena et al was the largest study with more than 50% of the total combined 279 fluid boluses, thus the power and precision of the results were limited. Secondly, different monitoring devices were used in the studies. The quantity and type of fluid administered, and the cut-off values for defining fluid responsiveness varied obviously between the included studies. All these diverse study characteristics may influence the predictive value of SVV. Thirdly, some patients received vasoactive drugs, which might interfere with the cardiopulmonary interactions. Finally, we did not include studies without available data to calculate sensitivity and specificity, non-English studies, and unpublished studies, which may have increased the risk of reporting bias.

Conclusions

This work is the first meta-analysis to evaluate the ability of SVV to predict the response to volume expansion in pediatric patients. Our results showed that SVV was of diagnostic value in predicting fluid responsiveness in children under mechanical ventilation. However, high heterogeneity was found between published studies, further studies are needed to confirm the diagnostic accuracy and utility of SVV in predicting fluid responsiveness in children.

Supporting information

S1 Fig. Deek's Funnel Plot Asymmetry Test for the assessment of potential publication bias.

https://doi.org/10.1371/journal.pone.0177590.s003

(TIFF)

Acknowledgments

This work was supported by the National Science Foundation of China (No. 81630038).

Author Contributions

  1. Conceptualization: CW DM.
  2. Data curation: LY ZL.
  3. Formal analysis: LY ZL.
  4. Funding acquisition: DM.
  5. Investigation: LY ZL.
  6. Methodology: LY ZL.
  7. Project administration: LQ CW DM.
  8. Resources: ZL.
  9. Software: LY.
  10. Supervision: CW DM.
  11. Validation: LY LQ.
  12. Visualization: LY ZL.
  13. Writing – original draft: LY ZL.
  14. Writing – review & editing: LQ CW DM.

References

  1. 1. Antonelli M, Levy M, Andrews PJ, Chastre J, Hudson LD, Manthous C, et al. Hemodynamic monitoring in shock and implications for management. International Consensus Conference, Paris, France, 27–28 April 2006. Intensive care medicine. 2007;33(4):575–90. pmid:17285286
  2. 2. Navarro LH, Bloomstone JA, Auler JO Jr., Cannesson M, Rocca GD, Gan TJ, et al. Perioperative fluid therapy: a statement from the international Fluid Optimization Group. Perioperative medicine. 2015;4:3. pmid:25897397
  3. 3. Carsetti A, Cecconi M, Rhodes A. Fluid bolus therapy: monitoring and predicting fluid responsiveness. Current opinion in critical care. 2015;21(5):388–94. pmid:26348418
  4. 4. Boyd JH, Forbes J, Nakada TA, Walley KR, Russell JA. Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality. Critical care medicine. 2011;39(2):259–65. pmid:20975548
  5. 5. Rosenberg AL, Dechert RE, Park PK, Bartlett RH, Network NNA. Review of a large clinical series: association of cumulative fluid balance on outcome in acute lung injury: a retrospective review of the ARDSnet tidal volume study cohort. Journal of intensive care medicine. 2009;24(1):35–46. pmid:19103612
  6. 6. Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008;134(1):172–8. pmid:18628220
  7. 7. Wiesenack C, Fiegl C, Keyser A, Prasser C, Keyl C. Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients. European journal of anaesthesiology. 2005;22(9):658–65. pmid:16163911
  8. 8. Eskesen TG, Wetterslev M, Perner A. Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness. Intensive care medicine. 2016;42(3):324–32. pmid:26650057
  9. 9. Sandroni C, Cavallaro F, Marano C, Falcone C, De Santis P, Antonelli M. Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis. Intensive care medicine. 2012;38(9):1429–37. Epub 2012/06/27. pmid:22732902
  10. 10. Ansari BM, Zochios V, Falter F, Klein AA. Physiological controversies and methods used to determine fluid responsiveness: a qualitative systematic review. Anaesthesia. 2016;71(1):94–105. Epub 2015/10/16. pmid:26459299
  11. 11. Hasanin A. Fluid responsiveness in acute circulatory failure. Journal of intensive care. 2015;3:50. pmid:26594361
  12. 12. Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. Journal of anesthesia. 2011;25(6):904–16. pmid:21892779
  13. 13. Saxena R, Durward A, Steeley S, Murdoch IA, Tibby SM. Predicting fluid responsiveness in 100 critically ill children: the effect of baseline contractility. Intensive care medicine. 2015;41(12):2161–9. pmid:26415680
  14. 14. Renner J, Broch O, Duetschke P, Scheewe J, Hocker J, Moseby M, et al. Prediction of fluid responsiveness in infants and neonates undergoing congenital heart surgery. British journal of anaesthesia. 2012;108(1):108–15. pmid:22113930
  15. 15. Gan H, Cannesson M, Chandler JR, Ansermino JM. Predicting fluid responsiveness in children: a systematic review. Anesthesia and analgesia. 2013;117(6):1380–92. pmid:24257389
  16. 16. Moher D, Liberati A, Tetzlaff J, Altman DG, Group P. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Int J Surg. 2010;8(5):336–41. pmid:20171303
  17. 17. Higgins JP, Thompson SG. Quantifying heterogeneity in a meta-analysis. Statistics in medicine. 2002;21(11):1539–58. pmid:12111919
  18. 18. Deeks JJ, Macaskill P, Irwig L. The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. Journal of clinical epidemiology. 2005;58(9):882–93. pmid:16085191
  19. 19. Zamora J, Abraira V, Muriel A, Khan K, Coomarasamy A. Meta-DiSc: a software for meta-analysis of test accuracy data. BMC medical research methodology. 2006;6:31. pmid:16836745
  20. 20. McLean JR, Inwald DP. The utility of stroke volume variability as a predictor of fluid responsiveness in critically ill children: a pilot study. Intensive care medicine. 2014;40(2):288–9. Epub 2013/12/07. pmid:24306083
  21. 21. Lee JY, Kim JY, Choi CH, Kim HS, Lee KC, Kwak HJ. The ability of stroke volume variation measured by a noninvasive cardiac output monitor to predict fluid responsiveness in mechanically ventilated children. Pediatric cardiology. 2014;35(2):289–94. pmid:23963186
  22. 22. Vergnaud E, Vidal C, Verchere J, Miatello J, Meyer P, Carli P, et al. Stroke volume variation and indexed stroke volume measured using bioreactance predict fluid responsiveness in postoperative children. British journal of anaesthesia. 2015;114(1):103–9. Epub 2014/10/16. pmid:25315146
  23. 23. Lee JH, No HJ, Song IK, Kim HS, Kim CS, Kim JT. Prediction of fluid responsiveness using a non-invasive cardiac output monitor in children undergoing cardiac surgery. British journal of anaesthesia. 2015;115(1):38–44. Epub 2015/05/01. pmid:25926311
  24. 24. Whiting PF, Rutjes AW, Westwood ME, Mallett S, Deeks JJ, Reitsma JB, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Annals of internal medicine. 2011;155(8):529–36. pmid:22007046
  25. 25. Hofer CK, Cannesson M. Monitoring fluid responsiveness. Acta anaesthesiologica Taiwanica: official journal of the Taiwan Society of Anesthesiologists. 2011;49(2):59–65.
  26. 26. Auler JO Jr., Galas FR, Sundin MR, Hajjar LA. Arterial pulse pressure variation predicting fluid responsiveness in critically ill patients. Shock. 2008;30 Suppl 1:18–22.
  27. 27. Desgranges FP, Desebbe O, Pereira de Souza Neto E, Raphael D, Chassard D. Respiratory variation in aortic blood flow peak velocity to predict fluid responsiveness in mechanically ventilated children: a systematic review and meta-analysis. Paediatric anaesthesia. 2016;26(1):37–47. pmid:26545173
  28. 28. Li C, Lin FQ, Fu SK, Chen GQ, Yang XH, Zhu CY, et al. Stroke volume variation for prediction of fluid responsiveness in patients undergoing gastrointestinal surgery. International journal of medical sciences. 2013;10(2):148–55. pmid:23329886
  29. 29. Min JJ, Lee JH, Hong KY, Choi SJ. Utility of stroke volume variation measured using non-invasive bioreactance as a predictor of fluid responsiveness in the prone position. Journal of clinical monitoring and computing. 2016. Epub 2016/03/12.
  30. 30. Biais M, Nouette-Gaulain K, Cottenceau V, Revel P, Sztark F. Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. British journal of anaesthesia. 2008;101(6):761–8. pmid:18852114
  31. 31. De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive care medicine. 2005;31(4):517–23. pmid:15754196
  32. 32. Suehiro K, Okutani R. Influence of tidal volume for stroke volume variation to predict fluid responsiveness in patients undergoing one-lung ventilation. Journal of anesthesia. 2011;25(5):777–80. pmid:21744128
  33. 33. Kang WS, Kim JY, Woo NS, Yoon TG. The influence of different mechanical ventilator settings of peak inspiratory pressure on stroke volume variation in pediatric cardiac surgery patients. Korean journal of anesthesiology. 2014;66(5):358–63. pmid:24910727
  34. 34. Marik PE. Noninvasive cardiac output monitors: a state-of the-art review. Journal of cardiothoracic and vascular anesthesia. 2013;27(1):121–34. pmid:22609340
  35. 35. Matthay MA, Chatterjee K. Bedside catheterization of the pulmonary artery: risks compared with benefits. Annals of internal medicine. 1988;109(10):826–34. pmid:3056159
  36. 36. Hett DA, Jonas MM. Non-invasive cardiac output monitoring. Intensive & critical care nursing. 2004;20(2):103–8.
  37. 37. Thiele RH, Bartels K, Gan TJ. Cardiac output monitoring: a contemporary assessment and review. Critical care medicine. 2015;43(1):177–85. pmid:25251758
  38. 38. Chand R, Mehta Y, Trehan N. Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery. Journal of cardiothoracic and vascular anesthesia. 2006;20(3):315–9. pmid:16750729
  39. 39. Tan HL, Pinder M, Parsons R, Roberts B, van Heerden PV. Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. British journal of anaesthesia. 2005;94(3):287–91. pmid:15653709
  40. 40. Marque S, Cariou A, Chiche JD, Squara P. Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring. Critical care (London, England). 2009;13(3):R73. Epub 2009/05/21.
  41. 41. Weisz DE, Jain A, McNamara PJ, EL-K A. Non-invasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography. Neonatology. 2012;102(1):61–7. Epub 2012/04/18. pmid:22508150
  42. 42. Akao M, Katsube Y, Kamisago M, Watanabe M, Abe M, Fukazawa R, et al. Developmental changes in left and right ventricular function evaluated with color tissue Doppler imaging and strain echocardiography. Journal of Nippon Medical School = Nippon Ika Daigaku zasshi. 2013;80(4):260–7. pmid:23995568
  43. 43. Miller-Hance W WI, Andropoulos DB. Developmental physiology of the cardiovascular system. In: Gregory GA AD, editor. Gregory’s Pediatric Anesthesia. Oxford: Wiley-Blackwell; 2012. p. 60–94.
  44. 44. Wolf AR, Humphry AT. Limitations and vulnerabilities of the neonatal cardiovascular system: considerations for anesthetic management. Paediatric anaesthesia. 2014;24(1):5–9. pmid:24330443
  45. 45. Senzaki H, Akagi M, Hishi T, Ishizawa A, Yanagisawa M, Masutani S, et al. Age-associated changes in arterial elastic properties in children. European journal of pediatrics. 2002;161(10):547–51. pmid:12297902
  46. 46. Sharp MK, Pantalos GM, Minich L, Tani LY, McGough EC, Hawkins JA. Aortic input impedance in infants and children. Journal of applied physiology. 2000;88(6):2227–39. pmid:10846040