Determination of an Optimal Standardized Uptake Value of Fluorodeoxyglucose for Positron Emission Tomography Imaging to Assess Pathological Volumes of Cervical Cancer: A Prospective Study

  • Ying Zhang ,

    Contributed equally to this work with: Ying Zhang, Jing Hu, Hong-Jun Lu

    Affiliation Department of Radiation Oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

  • Jing Hu ,

    Contributed equally to this work with: Ying Zhang, Jing Hu, Hong-Jun Lu

    Affiliation Department of Radiation Oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

  • Hong-Jun Lu ,

    Contributed equally to this work with: Ying Zhang, Jing Hu, Hong-Jun Lu

    Affiliation Department of Radiation Oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

  • Jian-Ping Li,

    Affiliation Department of Radiation Oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

  • Ning Wang,

    Affiliation Department of Radiation Oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

  • Wei-Wei Li,

    Affiliation Department of Radiation Oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

  • Yong-Chun Zhou,

    Affiliation Department of Radiation Oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

  • Jun-Yue Liu,

    Affiliation Department of Radiation Oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

  • Sheng-Jun Wang,

    Affiliation Department of Nuclear Medicine, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

  • Jing Wang,

    Affiliation Department of Nuclear Medicine, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

  • Xia Li,

    Affiliation Department of Pathology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

  • Wan-Ling Ma,

    Affiliation Department of Radiology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

  • Li-Chun Wei ,

    weilichun@fmmu.edu.cn (LCW); mshifmmu@yahoo.com (MS)

    Affiliation Department of Radiation Oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

  • Mei Shi

    weilichun@fmmu.edu.cn (LCW); mshifmmu@yahoo.com (MS)

    Affiliation Department of Radiation Oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China

Abstract

Purpose

To determine the optimal standardized uptake value (SUV) of 18F-fluorodeoxyglucose (18F-FDG) for positron emission tomography (PET) imaging, at which the PET-defined gross tumor volume (GTVPET) best matches with the pathological volume (GTVPATH) in the cervical cancer.

Materials and Methods

Ten patients with the cervical cancer who underwent surgery were enrolled in this study. The excised specimens were processed for whole-mount serial sections and H-E staining. The tumor borders were outlined in sections under a microscope, histopathological images were scanned and the GTVPATH calculated. The GTVPET was delineated automatically by using various percentages relative to the maximal SUV and absolute SUV. The optimal threshold SUV was further obtained as the value at which the GTVPET best matched with the GTVPATH.

Results

An average of 85±10% shrinkage of tissue was observed after the formalin fixation. The GTVPATH was 13.38±2.80 cm3 on average. The optimal threshold on percentile SUV and absolute SUV were 40.50%±3.16% and 7.45±1.10, respectively. The correlation analysis showed that the optimal percentile SUV threshold was inversely correlated with GTVPATH (p<0.05) and tumor diameter (p<0.05). The absolute SUV was also positively correlated with SUVmax (p<0.05).

Conclusion

The pathological volume could provide the more accurate tumor volume. The optimal SUV of FDG for PET imaging by use of GTVPATH as standard for cervical cancer target volume delineation was thus determined in this study, and more cases are being evaluated to substantiate this conclusion.

Introduction

The fluorine-18 fluorodeoxyglucose positron emission tomography (18F-FDG-PET) is a noninvasive three-dimensional imaging procedure that uses a glucose analogue as metabolic tracer. The FDG uptake increases in the cells with high metabolic rate, especially in tumor region, which appears as high-uptake hot spots in FDG-PET image. This imaging technique has been extensively evaluated and widely used for early diagnosis, staging, confirmation of lymph node metastasis and radiotherapy outcome in the cervical cancer [1], [2], [3]. Among these, the accuracy of PET/CT imaging in the diagnosis of gynecologic cancers including cervical cancer is higher than other conventional imaging methods [2].

It is well known that radiotherapy is a treatment of choice for cervical cancer, which can even be cured by radiotherapy alone. Delineation of tumor target volumes accurately has an important significance to achieve precise radiotherapy in the three-dimensional era of radiotherapy. Though CT and MRI have been widely used in radiotherapy planning, it is essential to acquire more information of tumor volume. Presently, it is difficult to discriminate normal soft tissue and tumor border on CT images, even in the contrast-enhanced CT. In this regard, MRI is better than CT for primary tumors and adjacent soft tissue involvement in the pelvis. But, 18F-FDG-PET can provide more metabolic activity information of tumor tissue in addition to anatomical tumor characterization. It demonstrated that 18F-FDG-PET could measure ‘metabolic volume’ to select the best candidates for radiotherapy [2], [3]. It is clear that 18F-FDG-PET may be an advanced imaging technique for target localization and radiation dose calculation for intracavitary brachytherapy and sophisticated external radiation treatment [4], [5]. Furthermore, interobserver variability was effectively decreased by using PET/CT scan in treatment planning and evaluation of response for the cervical cancer [6].

However, it is an unsolved and critical question on how to obtain PET images that will provide tumor target volume accurately, as PET/CT is being currently used more frequently in clinical cancer radiotherapy. Compared with the gross tumor volume (GTV) on CT, the volume of GTVPET changed in two of eight cases of the gynecological cancers. The radiotherapy planning had to be revised because the volume of GTVPET varied about 20±10% [7]. The tumor volumes based on PET/CT were also affected by the threshold level of standardized uptake value (SUV). The different threshold of SUV caused significant differences in radiation dose to target and normal tissues [8]. Identification of an optimal PET segmentation method could reduce these errors and interobserver variability in GTV delineation, and potentially allow for reduction in GTV expansions. Data from studies indicated no consensus in optimal SUV selection when PET/CT was utilized to outline radiotherapy target volume, especially in lung cancer, head and neck tumor [9], [10], [11].

In this study, we have compared the volume based on the PET/CT functional imaging information of the cervical cancer with the pathologic volume reconstructed by a technique of whole-mount serial sections. The aim of this study was to explore feasibility of using the reconstructed pathologic volume as the standard to determine the optimal SUV cutoff-value of PET/CT images and to provide an experimental basis for delineating biological target volume of cervical cancer. At the same time, the range of microscopic extension in the different directions of the cervical cancer was observed under a microscope to observe boundary of clinical target volume. To our knowledge, this is the first report on correlation of image-based radiotherapy target volume and reconstructed pathologic volume of the cervical cancer.

Materials and Methods

Patients group

Ten patients with histologically confirmed cervical cancer were selected for the present study at the Xijing Hospital between March 2010 and November 2010. The eligibility criteria were included as invasive squamous cell carcinoma with FIGO clinical stageIB-IIB. The patients were free of diabetes or other diseases that could affect the results of FDG-PET/CT, and had not undergone any cancer-related treatments previously. All patients underwent radical hysterectomy and pelvic lymphadenectomy and the 18F-FDG-PET/CT scans on the day before surgery. The protocol was approved by Hospital's Protection of Human Subjects Committee (Xijing Hospital, Fourth Military Medical University, Clinical Ethics Committee), and written consent was taken from all the patients.

PET/CT scan and gross target volume in PET image (GTVPET) definition

The FDG-PET/CT scan was performed with a hybrid PET/CT scanner (Biograph 40; Siemens Medical Solutions, Malvern, PA). All patients were asked to fast for at least 6 h before the PET examination and their blood glucose levels were checked before injecting the tracer. About forty to sixty minutes after intravenous injection of 18F-FDG (5.55–7.40MBq/kg), the CT image scan was extended from L3 to tuber ischiadicum by using 64-slice helical CT acquisition (140 KV, 90 mA, a slice thickness of 3 mm, a 50 cm displayed field of view, and a rotational speed of 0.75 s per rotation) and emission images were acquired covering the same axial range. The PET images were reconstructed with CT-derived attenuation correction using ordered-subset expectation maximization software.

The PET/CT images were reviewed by two experienced nuclear medicine physicians on Xeleris workstation. The tumor was characterized by an increased FDG uptake beyond expected normal tissue uptake (standardized uptake value (SUV) being >2.5). The gross target volume confirmed by absolute SUV level (GTVPET(SUV)) was calculated automatically by the True-D Software at various cut-off level of the absolute SUV, from 2.5 to 12.5 at 0.5 intervals (representative PET images at absolute SUV value of 2.5, 3.5, 4.5, 5.5, 6.5 and 7.5 shown in Fig. 1A). The gross target volume confirmed by percentile level of SUV (GTVPET(%SUV)) was calculated by same way at different percentile thresholds of the maximal SUV, from 10% to 60% at 5% interval (representative PET images at 10%, 20%, 30%, 40%, 50% or 60% percentile thresholds of the maximal SUV are shown in Fig. 1B).

thumbnail
Figure 1. Determination of the optimal standardized uptake value (SUV) cut-off value.

Data from case 6 is shown as a representative example. The serial gross tumor volumes on positron emission tomography (GTVPET) measured on the basis of each cut-off value (A, SUV = 1.5, 2.5, 3.5, 4.5 and 5.5; B, % SUV = 10, 20, 30, 40 and 50) are plotted according to the threshold relative to the absolute SUV (C) or percentages of maximal SUV (D). The optimal cut-off value is determined by the linear approximation with the best agreement between the GTVPET and pathologically determined GTV (GTVpath).

https://doi.org/10.1371/journal.pone.0075159.g001

Pathology procedure

All the patients underwent radical hysterectomy and pelvic lymphadenectomy. The tumor maximum diameter and vertical diameter were measured and recorded (Table 1). Once the specimens were obtained, tumor and cervix were measured and fixed using 10% formalin solution for 24h at room temperature. The maximum diameter and vertical diameter of fixed tumor were recorded again to calculate volume reduction (Fig. 2A, B.). Next, the specimens were cut into serial slices of 4 mm thickness. The slices were again cut into 4μm thick histological sections with a microtome (Microm HM 450; GMI, Ramsey, MN) after routine dehydration and paraffin-embedding procedure. The 4μm thick sections were processed for hematoxylin and eosin (HE) staining. Under a light microscope, the tumor border on the HE-stained histological slides was outlined by an experienced pathologist blinded to the imaging results (Fig. 2C). The regions of interest of the HE stained sections were captured by a digital camera with a ruler. The captured images were then dealt with Adobe Photoshop software and outlined tumor areas were calculated by histogram function of software layers of the pixel sections. Finally, the pathologic gross target volume (GTVPATH) was calculated according to summation formula, i.e. GTVPATH  =  Σ area × thickness/R, in which R was defined as the ratio of the sample dimensions before and after formalin fixation.

thumbnail
Figure 2. A representative sample showing measurement of pathologic gross tumor volume of cervical cancer.

The surgical specimen is oriented to the in vivo geometry and bisected in the transverse plane. The dimensions of the sample are measured before (A) and after formalin fixation (B). The fixed specimen is then sectioned into 4-6μm slices. In the sections stained with hematoxylin and eosin, the tumor-containing region is delineated by black line (C).

https://doi.org/10.1371/journal.pone.0075159.g002

thumbnail
Table 1. Summary in tumor size of pre- and post-fixation, retraction ratio of corresponding area and volume, and actual pathologic volume of ten cervical cancers.

https://doi.org/10.1371/journal.pone.0075159.t001

Determination about optimal cut-off value of SUV

The GTVPATH with the GTVPET(SUV) and GTVPET(%SUV) were compared case by case. A coordinate system was established with the vertical axis of absolute SUV or percentile SUV threshold and abscissa of GTVPET. A linear approximation could be seen between the adjacent two points in coordinate system. The GTVPET(SUV) and GTVPET(%SUV) were obtained best in agreement with GTVPATH by a first-order linear approximation (Fig. 1). The optimal cut-off value of SUV was the absolute or percentile values of SUV when the GTV PATH was equal to the GTVPET.

Statistical methods

All data were statistically analyzed by SPSS software (version 13.0) in this study. Wilconxon signed-rank test was used to compare GTVPET(SUV) and GTVPET(%SUV) with the corresponding GTVPATH. Spearman correlation test was used to analyze relationship between optimal cut-off absolute SUV or percentile SUV threshold, tumor maximum diameter and GTVPATH. The cases satisfying p<0.05 were considered as statistically significant for all comparison tests in this study.

Results

Patient details

All the patients were confirmed with the invasive squamous carcinoma of cervix. The median age of 10 patients was 40 years (ranging 32–55 years). The clinical stage (FIGO): 2 of IB, 3 of IIA and 5 of IIB. All patients exhibited abnormal radioactive uptake in tumor (SUV>2.5). No patient showed abnormal lymph nodes in the pelvic cavity.

Retraction of surgical specimen after fixation

The volume of tissue changed during the pathological procedure. A notable shrinkage of tissue occurred during the formalin fixation procedure. The mean volume of tumor after fixation was about 85%±10% (ranging 65–97%) of the original tumor volume (Table 1).

Optimal cut-off value of SUV

The mean SUVmax and SUVmean were 18.38±8.85 and 7.88±2.85, respectively. The SUV values varied among patients. The range of absolute SUV threshold was from 3.8 to 13.0 and the mean of optimal absolute SUV was 7.45±1.10. The percentile SUV threshold was from 24.9% to 55% and the mean of optimal percentile SUV was 40.50%±3.16% (Table 2).

thumbnail
Table 2. Summary in SUVs, GTVs and Diameters of ten cervical cancers.

https://doi.org/10.1371/journal.pone.0075159.t002

The correlation of SUV values with tumor pathologic volume and diameter was further analyzed. The optimal percentile SUV threshold was inversely correlated with GTVPATH (r = −0.8424, p = 0.0037) (Fig. 3A) and tumor diameter (r = −0.8085, p = 0.0072) (Fig. 3B).

thumbnail
Figure 3. Correlation analysis of presented data.

A correlation is shown between optimal percentile SUV threshold and the gross tumor volumes determined by pathology (A), or tumor diameter (B), and correlation shown between the maximal SUV and the optimal absolute SUV (C).

https://doi.org/10.1371/journal.pone.0075159.g003

There was a significant difference of the percentile SUV among the different tumor diameters or different pathologic volumes. When they were divided tumor into three groups by diameter, i.e. <2.5 cm, 2.5–4.5 cm, and >4.5 cm, the optimal percentile SUV was 52.4%±3.08%, 37.33%±3.54% and 32.83%±10.02%, respectively (p = 0.0126). The percentile SUV threshold for tumors of different pathologic volumes was 32.83%±10.02% for tumors being >15 cm3, 35.70%±1.71% for tumor volume ranging between 5–15 cm3, and 49.9%±5.67% for tumors being <5 cm3, respectively (p = 0.0224).

On the other hand, there was no significant correlation between the optimal absolute SUV value and tumor diameter (r = −0.07295, p = 0.8382) or volume (r = −0.07295, p = 0.8382). The optimal absolute SUV was 7.73±4.57 for tumor diameter being <2.5 cm, 6.89±3.32 for diameter being between 2.5 cm and 4.5 cm, and 7.90±4.00 for diameter being >4.5 cm, respectively (p = 0.9340). It was 7.90±4.00 for tumors of size >15 cm3, 5.32±1.32 for tumors of size 5–15 cm3, and 8.70±4.21 for tumors of size <5 cm3 (p  = 0.4829). The absolute SUV was positively correlated with SUVmax (r = 0.6921, p = 0.0306) (Fig. 3C). However, no significant correlation was identified between the optimal percentile SUV and SUVmax (r = −0.07295, p = 0.8382).

Discussion

The novelty of the present piece of study is that pathological volume could provide the more accurate tumor volume and the PET-defined gross tumor volume (GTVPET) matched best to the pathological volume(GTVPATH) in the cervical cancer. By using whole-mount serial section technique, it revealed that shrinkage rate of tumor volume was from 65% to 97% (mean 85±10%) after pathological process and actual volume of tumor was obtained by reconstruction procedure. Data of this study indicate that the actual tumor volume could be considered as more accurate volume and be potentially used as “the gold standard” to compare PET volume and further to determine the optimal SUV value in PET images for radiotherapy of cervical cancer.

The common methods confirming SUV value on PET imaging are roughly divided into three types. They included one studying the phantom, one comparing with other types of image, and one comparing with tumor size determined by pathological volume. Through phantom studies, the researchers found an optimal SUV thresholds for PET as between 36% to 44% for sphere volume larger than 4 mm3 and the exact value might depend on the source-to-background (S/B) ratios [12]. The optimal SUV threshold changed while it was compared with the static phantom and moving phantom [11], [13], [14]. When FDG-filled different diameter phantom was utilized, the appropriate threshold level depended on lesion size [8] and 40–50% of the maximum SUV seemed to be appropriate for GTV contouring of sphere tumors with homogenously distributed 18F-FDG [15]. Besides, the FDG uptake in a tumor tissue showed a more gradual decrease toward the tumor edge and might be also affected by other blurring effects, such as respiratory motion, given the FDG-avid volumes in phantom studies were demarcated sharply.

To obtain the best SUV value, there were many studies comparing PET image with other type of image, especially CT, which was most commonly used to delineate the target volume for radiotherapy planning. Nestle U et al compared the GTVs with confirmation of four methods in 25 patients with primary non small cell lung carcinoma (NSCLC), and found that a threshold of 40% of the maximum standardized uptake value was not suitable for target volume delineation [16]. Biehl KJ et al reported that a single standardized uptake value threshold was not adequate for NSCLC [17]. In a later observation, Hong R et al recommended a method using SUV being ≥2.5 for radiotherapy planning in NSCLC by comparing with CT [18]. Researchers contoured the GTVs with six different “observers”, i.e. two radiation oncologists, two nuclear medicine physicians and two radiologists, by using SUV cutoffs of 2.5 and 3.5 and 40% SUVmax in 6 NSCLC patients. They found an SUV contour of 2.5 was most closely correlated with the mean GTV defined by the interobservers [19]. In other types of tumors such as esophageal cancer, a threshold of approximate 2.5 yielded the highest conformality index and approximate CT-based GTV at the epicenter [20]. Obviously, researchers might get various SUV suitable for different sizes and types of tumor. Currently, CT or MRI was widely used in contoured tumor and the image was easier obtained. However, both CT and MRI also exhibited disadvantages in delineating tumor border accurately, which mostly depended on personal experience in a large extent and tumor volume on CT was often overestimated.

Furthermore, some researchers calculated the actual tumor volume and used it as a reference standard to find best SUV value. Burri RJ et al studied the correlation of PET SUV with pathologic specimen size in patients with head-and-neck cancers. They drew a conclusion that the SUV40 method might appear to offer balance between accuracy and reducing risk of underestimating tumor extent [21]. In the esophageal cancer, the mean optimal threshold was 23.81%±11.29%, but the optimal threshold was different with various tumor sizes. An SUV cutoff of 2.5 provided the closest estimation when the length of PET matched the length of pathology [22]. In NSCLC researches, Yu et al found an optimal threshold of 31%±11% and an absolute SUV of 3.0±1.6, respectively [9]. Similarly, the threshold SUV varied with different tumor diameter (>5 cm, 3–5 cm, and <3 cm), but the difference was not significant statistically. In those studies, the pathologic specimen was used as the “gold standard”, which was recommended to reflect actual tumor volume more accurately.

In previous feasibility studies, a threshold of 40%–50% of maximum SUV was found to be a reliable correlate to tumor volume measured by CT [7], when the use of PET/CT was evaluated in radiation therapy planning. However, SUV on PET might vary with different anatomical sites, organizational characteristics and tumor activity in different type of cancer. In a retrospective study, Nguyen et al compared the SUVmax of FDG PET in four different sites and found that no common SUVmax threshold exists [23]. In another retrospective study, Chung et al measured the metabolic tumor volume(MTV) by integrated FDG-PET/CT imaging and used a fixed threshold of SUV 2.5 and found the MTV was good correlated with tumor volume calculated from surgical specimen [24]. This result was similar with previous report in the lung cancer [25]. However, the results of our prospective study further indicated an increased optimal threshold SUV or absolute SUV in cervical cancer compared with that of esophageal cancer or NSCLC, and the difference might mainly result from the less tumor motion in cervical cancer.

In this study, data showed that optimal percentile threshold SUV varied with changes of tumor volume. The optimal percentile threshold SUV reduced when the tumor volume increased, although the differences were not significant statistically. In contrast, no correlation was observed between the absolute SUV and tumor size of the cervical cancer. The optimal percentile threshold SUV showed an inverse correlation with GTVPATH and tumor diameter in our study, which was well consistent with previous report in NSCLC [9]. Another research indicated that the optimal PET threshold was inversely correlated with the GTVCT [17]. Besides, it also found an increased accuracy by using a threshold function, relative to a constant threshold in phantom [26]. One study recently showed that 40% threshold was suitable for calculating the volume of any lesion with diameter being >1.83 cm, 60% for diameter being >1.35 cm but <1.83 cm, and 75% for diameter being <1.35 cm by phantom observation [27]. The overall results indicate that a fixed SUV cut-off might not be appropriate to all tumor volumes.

To the best of our knowledge, there are few research reports comparing tumor volumes determined by different imaging modalities with surgical specimens in the cervical squamous cell tumors, and we thus concluded that GTVs derived from the PET images matched those from microscopy more accurately [28]. This is a first observation in cervical cancer for PET SUV determination, and the data of this study could provide a basis and reference for SUV selected for PET image in the cervical cancer. In addition, it may need to point out that a limitation of this study was small number of cases, relatively small tumor diameter and tumor volume of samples enrolled. More cases with various tumor volumes and diameters should be included and should be performed for further validation of this study.

Conclusion

In this study, the SUV of 18F-FDG-PET image was studied by comparing GTVPET and GTVPATH in the cervical cancers. Data analysis indicated that pathological volume provided a more accurate tumor volume. The optimal SUV of PET imaging is thus proposed to use GTVPATH as standard for cervical cancer target volume delineation for improving the radiotherapy planning. Currently, more cervical cancer cases are being investigated to substantiate this conclusion.

Acknowledgments

Authors also thank Prof. Z. Wang and Y. Huan of The Fourth Military Medical University, Prof. J.M. Yu and D.B. Mu of Shandong Cancer Hospital and Institute for their supports in this study.

Author Contributions

Conceived and designed the experiments: LCW MS. Performed the experiments: YZ HJL JPL NW WWL YCZ JYL. Analyzed the data: YZ NW LCW. Contributed reagents/materials/analysis tools: SJW JW XL WLM. Wrote the paper: YZ JH LCW.

References

  1. 1. Kim EE (2004) Whole-body positron emission tomography and positron emission tomography/computed tomography in gynecologic oncology. Int J Gynecol Cancer 14: 12–22.
  2. 2. Grisaru D, Almog B, Levine C, Metser U, Fishman A, et al. (2004) The diagnostic accuracy of 18F-fluorodeoxyglucose PET/CT in patients with gynecological malignancies. Gynecol Oncol 94: 680–684.
  3. 3. Chung HH, Jo H, Kang WJ, Kim JW, Park NH, et al. (2007) Clinical impact of integrated PET/CT on the management of suspected cervical cancer recurrence. Gynecol Oncol 104: 529–534.
  4. 4. Miller TR, Grigsby PW (2002) Measurement of tumor volume by PET to evaluate prognosis in patients with advanced cervical cancer treated by radiation therapy. Int J Radiat Oncol Biol Phys 53: 353–359.
  5. 5. Mutic S, Grigsby PW, Low DA, Dempsey JF, Harms WB, et al. (2002) PET-guided three-dimensional treatment planning of intracavitary gynecologic implants. Int J Radiat Oncol Biol Phys 52: 1104–1110.
  6. 6. Tejwani A, Lavaf A, Parikh K, Mokhtar B, Swamy U, et al. (2012) The role of PET/CT in decreasing inter-observer variability in treatment planning and evaluation of response for cervical cancer. Am J Nucl Med Mol Imaging 3: 307–313.
  7. 7. Ciernik IF, Dizendorf E, Baumert BG, Reiner B, Burger C, et al. (2003) Radiation treatment planning with an integrated positron emission and computer tomography (PET/CT): a feasibility study. Int J Radiat Oncol Biol Phys 57: 853–863.
  8. 8. Ford EC, Kinahan PE, Hanlon L, Alessio A, Rajendran J, et al. (2006) Tumor delineation using PET in head and neck cancers: threshold contouring and lesion volumes. Med Phys 33: 4280–4288.
  9. 9. Yu J, Li X, Xing L, Mu D, Fu Z, et al. (2009) Comparison of tumor volumes as determined by pathologic examination and FDG-PET/CT images of non-small-cell lung cancer: a pilot study. Int J Radiat Oncol Biol Phys 75: 1468–1474.
  10. 10. Giraud P, Grahek D, Montravers F, Carette MF, Deniaud-Alexandre E, et al. (2001) CT and (18)F-deoxyglucose (FDG) image fusion for optimization of conformal radiotherapy of lung cancers. Int J Radiat Oncol Biol Phys 49: 1249–1257.
  11. 11. Caldwell CB, Mah K, Skinner M, Danjoux CE (2003) Can PET provide the 3D extent of tumor motion for individualized internal target volumes? A phantom study of the limitations of CT and the promise of PET. Int J Radiat Oncol Biol Phys 55: 1381–1393.
  12. 12. Erdi YE, Mawlawi O, Larson SM, Imbriaco M, Yeung H, et al. (1997) Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding. Cancer 80: 2505–2509.
  13. 13. Yaremko B, Riauka T, Robinson D, Murray B, Alexander A, et al. (2005) Thresholding in PET images of static and moving targets. Phys Med Biol 50: 5969–5982.
  14. 14. Nagel CC, Bosmans G, Dekker AL, Ollers MC, De Ruysscher DK, et al. (2006) Phased attenuation correction in respiration correlated computed tomography/positron emitted tomography. Med Phys 33: 1840–1847.
  15. 15. Uto F, Shiba E, Onoue S, Yoshimura H, Takada M, et al. (2010) Phantom study on radiotherapy planning using PET/CT – delineation of GTV by evaluating SUV. J Radiat Res (Tokyo) 51: 157–164.
  16. 16. Nestle U, Kremp S, Schaefer-Schuler A, Sebastian-Welsch C, Hellwig D, et al. (2005) Comparison of different methods for delineation of 18F-FDG PET-positive tissue for target volume definition in radiotherapy of patients with non-Small cell lung cancer. J Nucl Med 46: 1342–1348.
  17. 17. Biehl KJ, Kong FM, Dehdashti F, Jin JY, Mutic S, et al. (2006) 18F-FDG PET definition of gross tumor volume for radiotherapy of non-small cell lung cancer: is a single standardized uptake value threshold approach appropriate? J Nucl Med 47: 1808–1812.
  18. 18. Hong R, Halama J, Bova D, Sethi A, Emami B (2007) Correlation of PET standard uptake value and CT window-level thresholds for target delineation in CT-based radiation treatment planning. Int J Radiat Oncol Biol Phys 67: 720–726.
  19. 19. Bayne M, Hicks RJ, Everitt S, Fimmell N, Ball D, et al. (2010) Reproducibility of “intelligent” contouring of gross tumor volume in non-small-cell lung cancer on PET/CT images using a standardized visual method. Int J Radiat Oncol Biol Phys 77: 1151–1157.
  20. 20. Vali FS, Nagda S, Hall W, Sinacore J, Gao M, et al. (2010) Comparison of standardized uptake value-based positron emission tomography and computed tomography target volumes in esophageal cancer patients undergoing radiotherapy. Int J Radiat Oncol Biol Phys 78: 1057–1063.
  21. 21. Burri RJ, Rangaswamy B, Kostakoglu L, Hoch B, Genden EM, et al. (2008) Correlation of positron emission tomography standard uptake value and pathologic specimen size in cancer of the head and neck. Int J Radiat Oncol Biol Phys 71: 682–688.
  22. 22. Zhong X, Yu J, Zhang B, Mu D, Zhang W, et al. (2009) Using 18F-fluorodeoxyglucose positron emission tomography to estimate the length of gross tumor in patients with squamous cell carcinoma of the esophagus. Int J Radiat Oncol Biol Phys 73: 136–141.
  23. 23. Nguyen NC, Kaushik A, Wolverson MK, Osman MM (2011) Is there a common SUV threshold in oncological FDG PET/CT, at least for some common indications? A retrospective study. Acta Oncol. 50: 670–7.
  24. 24. Chung HH, Kim JW, Han KH, Eo JS, Kang KW, et al. (2011) Prognostic value of metabolic tumor volume measured by FDG-PET/CT in patients with cervical cancer. Gynecol Oncol. 120: 270–4.
  25. 25. Ashamalla H, Rafla S, Parikh K, Mokhtar B, Goswami G, et al. (2005) The contribution of integrated PET/CT to the evolving definition of treatment volumes in radiation treatment planning in lung cancer. Int J Radiat Oncol Biol Phys 63: 1016–1023.
  26. 26. Black QC, Grills IS, Kestin LL, Wong CY, Wong JW, et al. (2004) Defining a radiotherapy target with positron emission tomography. Int J Radiat Oncol Biol Phys 60: 1272–1282.
  27. 27. Gupta A, Sharma P, Patel CD, Maharjan S, Pandey A, et al. (2011) Size-dependent thresholding as an optimal method for tumor volume delineation on positron emission tomography-computed tomography: A Phantom study. Indian J Nucl Med 26: 22–26.
  28. 28. Daisne JF, Duprez T, Weynand B, Lonneux M, Hamoir M, et al. (2004) Tumor volume in pharyngolaryngeal squamous cell carcinoma: comparison at CT, MR imaging, and FDG PET and validation with surgical specimen. Radiology 233: 93–100.