-->PONE-D-26-09272-->-->Diagnostic Accuracy of Automated Hematology Analyzer Abnormal Flags for Detecting Hematological Malignancies: A Systematic Review and Meta-Analysis-->-->PLOS One Dear Dr. Mulatie, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. ACADEMIC EDITOR: Major revision Please submit your revised manuscript by Jul 26 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:-->
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. As the corresponding author, your ORCID iD is verified in the submission system and will appear in the published article. PLOS supports the use of ORCID, and we encourage all coauthors to register for an ORCID iD and use it as well. Please encourage your coauthors to verify their ORCID iD within the submission system before final acceptance, as unverified ORCID iDs will not appear in the published article. Only the individual author can complete the verification step; PLOS staff cannot verify ORCID iDs on behalf of authors. We look forward to receiving your revised manuscript. Kind regards, Marwan Salih Al-Nimer, MD, PhD Academic Editor PLOS One Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. We note that your Data Availability Statement is currently as follows: [All relevant data are within the manuscript and its Supporting Information files.] Please confirm at this time whether or not your submission contains all raw data required to replicate the results of your study. Authors must share the “minimal data set” for their submission. PLOS defines the minimal data set to consist of the data required to replicate all study findings reported in the article, as well as related metadata and methods (https://journals.plos.org/plosone/s/data-availability#loc-minimal-data-set-definition). For example, authors should submit the following data: - The values behind the means, standard deviations and other measures reported; - The values used to build graphs; - The points extracted from images for analysis. Authors do not need to submit their entire data set if only a portion of the data was used in the reported study. If your submission does not contain these data, please either upload them as Supporting Information files or deposit them to a stable, public repository and provide us with the relevant URLs, DOIs, or accession numbers. For a list of recommended repositories, please see https://journals.plos.org/plosone/s/recommended-repositories. If there are ethical or legal restrictions on sharing a de-identified data set, please explain them in detail (e.g., data contain potentially sensitive information, data are owned by a third-party organization, etc.) and who has imposed them (e.g., an ethics committee). Please also provide contact information for a data access committee, ethics committee, or other institutional body to which data requests may be sent. If data are owned by a third party, please indicate how others may request data access. 3. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information. 4. If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions -->Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. --> Reviewer #1: Yes Reviewer #2: Yes ********** -->2. Has the statistical analysis been performed appropriately and rigorously? --> Reviewer #1: Yes Reviewer #2: Yes ********** -->3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.--> Reviewer #1: Yes Reviewer #2: Yes ********** -->4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.--> Reviewer #1: Yes Reviewer #2: No ********** -->5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)--> Reviewer #1: This manuscript addresses a clinically relevant question regarding the diagnostic utility of abnormal hematology analyzer flags for hematological malignancies. The study has potential value, particularly for laboratories in resource-limited settings where automated screening tools may support early case identification and improve laboratory workflow. The manuscript includes several strengths, including use of standard diagnostic meta-analysis techniques, subgroup analyses, and clinical utility assessments. However, substantial revisions are required before the manuscript can meet the methodological and reporting standards expected for publication in PLOS ONE. The major concerns include: extremely high heterogeneity, pooling of clinically heterogeneous conditions and flag types, inconsistent reference standards, possible non-independence of datasets, insufficient methodological transparency, and overinterpretation of pooled findings. In addition, the manuscript requires substantial language editing and restructuring of the discussion section to reduce repetition and improve analytical depth. Reviewer #2: This systematic review and meta-analysis addresses an important and clinically relevant topic. The evaluation of automated hematology analyzer abnormal flags for the detection of hematological malignancies is of practical significance, particularly in settings where rapid and cost-effective screening tools are needed. The manuscript is generally well organized, and the authors have applied recognized methods for diagnostic test accuracy meta-analysis. However, several issues should be addressed before the manuscript can be considered for publication. Major comments 1. The search strategy requires clarification. The supplementary search strategy includes a randomized controlled trial filter in PubMed despite the review focusing on diagnostic accuracy studies. The rationale for this approach should be explained, and the authors should discuss whether relevant studies may have been inadvertently excluded. In addition, the search syntax contains several formatting inconsistencies and should be presented in a fully reproducible manner. 2. The pooled analyses demonstrate extremely high heterogeneity for both sensitivity and specificity. Although subgroup analyses and meta-regression were performed, the manuscript would benefit from a more detailed discussion of the sources of heterogeneity and their implications for interpretation of the pooled estimates. 3. Several publications contributed multiple datasets to the meta-analysis. The authors should clarify how these datasets were handled statistically and discuss any potential impact on the pooled results. 4. The included studies used different reference standards, including microscopy, flow cytometry, bone marrow examination, and combined approaches. The potential influence of this variability on diagnostic accuracy estimates should be discussed more thoroughly. 5. The conclusions should be moderated to emphasize that abnormal analyzer flags are useful screening tools but cannot replace confirmatory diagnostic methods such as peripheral blood smear review, flow cytometry, or bone marrow examination. Minor comments 1. The manuscript requires substantial English-language editing. Numerous grammatical errors, typographical errors, and awkward sentence constructions are present throughout the text. 2. Terminology should be standardized throughout the manuscript to improve clarity and consistency. 3. Table 1 would benefit from improved formatting and clearer presentation of multiple datasets originating from the same publication. Overall, this study addresses an important topic and has the potential to make a useful contribution to the field. However, the methodological and reporting issues outlined above should be addressed before the manuscript is considered for publication. ********** -->6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.--> Reviewer #1: Yes: GYESI RAZAK ISSAHAKU Reviewer #2: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation. NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications. |
| Revision 1 |
|
Diagnostic Accuracy of Automated Hematology Analyzer Abnormal Flags for Detecting Hematological Malignancies: A Systematic Review and Meta-Analysis PONE-D-26-09272R1 Dear Dr. Zewudu Mulatie, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. For questions related to billing, please contact billing support. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Marwan Salih Al-Nimer, MD, PhD Academic Editor PLOS One Additional Editor Comments (optional): Reviewers' comments: |
| Formally Accepted |
|
PONE-D-26-09272R1 PLOS One Dear Dr. Mulatie, I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS One. Congratulations! Your manuscript is now being handed over to our production team. At this stage, our production department will prepare your paper for publication. This includes ensuring the following: * All references, tables, and figures are properly cited * All relevant supporting information is included in the manuscript submission, * There are no issues that prevent the paper from being properly typeset You will receive further instructions from the production team, including instructions on how to review your proof when it is ready. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few days to review your paper and let you know the next and final steps. Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. You will receive an invoice from PLOS for your publication fee after your manuscript has reached the completed accept phase. If you receive an email requesting payment before acceptance or for any other service, this may be a phishing scheme. Learn how to identify phishing emails and protect your accounts at https://explore.plos.org/phishing. If we can help with anything else, please email us at customercare@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Professor Marwan Salih Al-Nimer Academic Editor PLOS One |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .