Peer Review History
| Original SubmissionFebruary 11, 2026 |
|---|
|
-->PONE-D-26-07168-->-->Double-cuff versus single-cuff bronchial blockers for video-assisted thoracoscopic lobectomy: a randomised controlled trial-->-->PLOS One Dear Dr. Zhou, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Apr 23 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:-->
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Luca Bertolaccini, M.D., Ph.D. Academic Editor PLOS One Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. We note that the grant information you provided in the ‘Funding Information’ and ‘Financial Disclosure’ sections do not match. When you resubmit, please ensure that you provide the correct grant numbers for the awards you received for your study in the ‘Funding Information’ section. 3. Please note that funding information should not appear in any section or other areas of your manuscript. We will only publish funding information present in the Funding Statement section of the online submission form. Please remove any funding-related text from the manuscript. 4. We note that you have a patent relating to material pertinent to this article. Please provide an amended statement of Competing Interests to declare this patent (with details including name and number), along with any other relevant declarations relating to employment, consultancy, patents, products in development or modified products etc. Please confirm that this does not alter your adherence to all PLOS ONE policies on sharing data and materials, as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests by including the following statement: "This does not alter our adherence to PLOS ONE policies on sharing data and materials.” If there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared. This information should be included in your cover letter; we will change the online submission form on your behalf. 5. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information. 6. Thank you for providing your underlying data as Supporting Information. We note that the data set contains text or data that is not in English. Please note that PLOS is an English-language publisher, so we require data sets to be provided in English as well. Please upload an English-language version of your data set. This will also allow us to determine if your data follows PLOS standards per our Data Availability policy here: https://journals.plos.org/plosone/s/data-availability 7. If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions -->Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. --> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Partly ********** -->2. Has the statistical analysis been performed appropriately and rigorously? --> Reviewer #1: No Reviewer #2: Yes Reviewer #3: No ********** -->3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.--> Reviewer #1: Yes Reviewer #2: No Reviewer #3: No ********** -->4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.--> Reviewer #1: No Reviewer #2: No Reviewer #3: Yes ********** -->5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)--> Reviewer #1: This randomized controlled trial compares the performance of a novel double-cuff bronchial blocker (DcBB) with a conventional single-cuff bronchial blocker (ScBB) during video-assisted thoracoscopic lobectomy. The authors demonstrate that the DcBB significantly reduces the incidence of malpositioning without increasing adverse events, highlighting its potential as an effective airway management tool. While the study addresses an important clinical issue and provides valuable insights, several methodological, statistical, and language issues need to be addressed before the manuscript can be considered for publication. My specific comments are as follows. 1. Randomization and Allocation Concealment The use of a computer-generated random number table to randomly assign patients is documented. However, there is no description of how the randomization sequence was concealed until the time of assignment (e.g., whether opaque, sealed envelopes with sequential numbers were used, or whether a central registration system was employed). This is an important item in the CONSORT statement. Please specify. 2. Statistical Analysis 2-1. Lines 114-117: Because the number of patients who experienced these events was low, Fisher's exact test should be used instead of the chi-square test. 2-2. Table 2: In the "Difference" column, please specify the point estimate in addition to the 95% CI. Furthermore, in the "Risk ratio" column, the calculated values seem to represent the Odds Ratio rather than the Risk Ratio. Please clarify and correct this. 2-3. Table 3: In the "Risk ratio" column, the calculation seems to be based on the number of patients who did NOT experience the events. Please correct this to reflect the occurrence of the events. 3. Language and Formatting Issues The manuscript requires thorough language editing. Here are specific examples of errors that need to be corrected: 3-1 Abstract (Methods): The sentence "we enrolled and randomized 80 patients..." begins with a lowercase "w". 3-2 Abstract (Methods): There is a missing period before "The primary outcomes": "...(ScBB used during one-lung ventilation) The primary outcomes...". 3-3 Abstract (Results): There is an unnecessary comma in: "...significantly lower in the DcBB, than the ScBB group...". 3-4 Abstract (Results): There is a missing period before "However": "...in the DcBB cohort (P=0.002) However, positioning the DcBB...". 3-5 Line 131: There is a missing period between sentences: "Between-group differences were not significant The duration of BB placement...". 3-6 Lines 139-150: The text contains a major structural issue that leaves sentences disjointed and garbled. For example, a sentence cuts off with "The malposition", continues awkwardly on the next line, and later abruptly inserts fragments like "rate of the DLT is lower than that of BBs¹s and a meta-analysis also found a rate of 17.0%,14 which was" in the middle of a different thought. This entire paragraph needs to be rewritten for coherence. 3-7 Line 154: There is a typo in the word "skills": "...in terms of bronchoscopic skilss...". 3-8 Table 3: There is a typo in the variable name: "Contamination rate of non-surgica" instead of "non-surgical". Reviewer #2: PONE-D-26-07168 1. was an intent to treat approach used? 2. please provide details of randomization. When were the anesthesiologist and the surgeon informed about the allocation? HOw was allocation concealed until then? 3. Please specify how the groups were so equally balanced? Was blocking used? If not, please give more details about the allocation. 4. Details of randomization deserves its own section. 5. Please remove p values from Table 1 6. Please standardize number of decimal places in tables. 7. Please present pvalues or CIs in Table 4. 8. Please describe the flow diagram in the results section. 9. Would a GEE that took into account the multiple measures for arterial partial pressure of oxygen and CO2 be useful? 10. A careful reading for grammar, especially verb tense, is necessary. Reviewer #3: This manuscript reports a randomized clinical trial comparing a double-cuff bronchial blocker (DcBB) with a conventional single-cuff bronchial blocker (ScBB) for thoracoscopic lobectomy. Although the topic is clinically relevant, several major methodological limitations substantially undermine the validity of the findings. For these reasons, I cannot recommend publication in its current form. 1. A critical limitation of this study is that both anesthesiologists and surgeons were aware of the allocated intervention during the procedure. The manuscript explicitly states that the operators could easily determine which bronchial blocker was used and therefore were aware of group allocation. Because the primary endpoint (malposition) is largely dependent on intraoperative clinical judgment and bronchoscopy assessment by the treating anesthesiologist, the absence of blinding introduces a substantial risk of performance and detection bias. In device trials where operator technique strongly influences outcomes, lack of blinding severely limits the reliability of comparative conclusions. Consequently, the study design does not sufficiently support the causal inference that the double-cuff device reduces malposition. 2. The primary endpoint—bronchial blocker malposition—is not rigorously defined. In this study, malposition was considered when airway pressure increased, ventilation could not be maintained, or the surgical lung suddenly inflated, followed by confirmation using bronchoscopy. These criteria are nonspecific and may occur for multiple intraoperative reasons unrelated to blocker displacement. Moreover, the decision to perform bronchoscopy and confirm malposition appears to rely on the judgment of the anesthesiologist who was aware of the device type. Without predefined objective bronchoscopic criteria or independent adjudication, the validity and reproducibility of the primary endpoint remain questionable. 3. Several authors are listed as inventors of the investigated double-cuff bronchial blocker and hold a related patent. While such involvement does not necessarily invalidate the research, it increases the importance of strict methodological safeguards such as independent outcome adjudication or blinded assessment. These safeguards are not present in this study, which further raises concerns about bias. 4. Although a statistical difference in malposition incidence was reported, the study failed to demonstrate meaningful differences in clinically relevant secondary outcomes such as hypoxemia, surgical duration, lung collapse quality, or postoperative complications. Therefore, even if the reported reduction in malposition were valid, the clinical benefit of the device remains unclear. 5. The authors conclude that the double-cuff bronchial blocker may be a superior airway management tool. However, the data do not convincingly demonstrate superiority. In fact, device positioning required significantly longer time in the DcBB group. Furthermore, the mechanistic rationale for why an additional cuff should substantially reduce malposition is not convincingly supported by either experimental data or prior literature. 6. The sample size calculation is also questionable. The authors assumed a malposition rate of 40% in the single-cuff BB group, even though the single-cuff blocker represents a standard and widely used device in current practice. This assumption appears inflated and insufficiently justified. An overestimated control event rate can artificially reduce the required sample size and make the investigational device appear more favorable. Therefore, the statistical planning itself raises concern regarding the internal validity of the trial. ********** -->6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.--> Reviewer #1: No Reviewer #2: No Reviewer #3: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation. NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications. |
| Revision 1 |
|
-->PONE-D-26-07168R1-->-->Double-cuff versus single-cuff bronchial blockers for video-assisted thoracoscopic lobectomy: a randomized controlled trial-->-->PLOS One Dear Dr. Zhou, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by May 29 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:-->
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. As the corresponding author, your ORCID iD is verified in the submission system and will appear in the published article. PLOS supports the use of ORCID, and we encourage all coauthors to register for an ORCID iD and use it as well. Please encourage your coauthors to verify their ORCID iD within the submission system before final acceptance, as unverified ORCID iDs will not appear in the published article. Only the individual author can complete the verification step; PLOS staff cannot verify ORCID iDs on behalf of authors. We look forward to receiving your revised manuscript. Kind regards, Luca Bertolaccini, M.D., Ph.D. Academic Editor PLOS One Journal Requirements: If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise. Additional Editor Comments: I would urge the authors to carefully read the remarks of Reviewers and consider these in the revised paper. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions -->Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation.--> Reviewer #1: (No Response) Reviewer #2: All comments have been addressed Reviewer #3: All comments have been addressed ********** -->2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. --> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** -->3. Has the statistical analysis been performed appropriately and rigorously? --> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: No ********** -->4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.--> Reviewer #1: Yes Reviewer #2: No Reviewer #3: Yes ********** -->5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.--> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** -->6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)--> Reviewer #1: The authors have largely addressed the previous comments appropriately. However, the following issues still require attention. The statement “P > 0.05” in the Results section of the main text does not add any meaningful information and should be removed. The estimated odds ratio for the “Contamination rate of non-surgical” in Table 3 appears not to have converged. It would be more appropriate to report this as “Not estimated.” The P-value for the between-group comparison at T0 in Table 4 should be removed. Reviewer #2: (No Response) Reviewer #3: Thank you for your efforts in revising the manuscript and for providing detailed responses to the reviewers’ comments. The revisions have improved the clarity of reporting, statistical presentation, and overall structure of the manuscript. However, several critical concerns remain that limit the scientific rigor and clinical applicability of the study. You appropriately acknowledge that blinding of operators was not feasible due to the nature of the devices. However, this limitation is particularly important in the context of this study, as both the intervention and outcome assessment are operator-dependent. The lack of blinding, combined with the subjective components of outcome detection, continues to pose a significant threat to internal validity. Most importantaly, although additional references have been provided to support the assumed malposition rate in the control group, the chosen assumptions still appear optimistic and may have influenced the estimated effect size and required sample size. This raises concerns regarding the robustness of the statistical planning. Given the methodological limitations and the absence of demonstrated clinical benefit, the conclusion that the double-cuff bronchial blocker represents a meaningful alternative for airway management is not sufficiently supported by the current data. ********** -->7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.--> Reviewer #1: No Reviewer #2: No Reviewer #3: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation. NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications. |
| Revision 2 |
|
Double-cuff versus single-cuff bronchial blockers for video-assisted thoracoscopic lobectomy: a randomized controlled trial PONE-D-26-07168R2 Dear Dr. Zhou, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. For questions related to billing, please contact billing support. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Luca Bertolaccini, M.D., Ph.D. Academic Editor PLOS One Additional Editor Comments (optional): Reviewers' comments: Reviewer's Responses to Questions -->Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation.--> Reviewer #1: All comments have been addressed Reviewer #2: All comments have been addressed ********** -->2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. --> Reviewer #1: Yes Reviewer #2: Yes ********** -->3. Has the statistical analysis been performed appropriately and rigorously? --> Reviewer #1: Yes Reviewer #2: Yes ********** -->4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.--> Reviewer #1: Yes Reviewer #2: Yes ********** -->5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.--> Reviewer #1: Yes Reviewer #2: Yes ********** -->6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)--> Reviewer #1: (No Response) Reviewer #2: (No Response) ********** -->7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.--> Reviewer #1: No Reviewer #2: No ********** |
| Formally Accepted |
|
PONE-D-26-07168R2 PLOS One Dear Dr. Zhou, I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS One. Congratulations! Your manuscript is now being handed over to our production team. At this stage, our production department will prepare your paper for publication. This includes ensuring the following: * All references, tables, and figures are properly cited * All relevant supporting information is included in the manuscript submission, * There are no issues that prevent the paper from being properly typeset You will receive further instructions from the production team, including instructions on how to review your proof when it is ready. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few days to review your paper and let you know the next and final steps. Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. You will receive an invoice from PLOS for your publication fee after your manuscript has reached the completed accept phase. If you receive an email requesting payment before acceptance or for any other service, this may be a phishing scheme. Learn how to identify phishing emails and protect your accounts at https://explore.plos.org/phishing. If we can help with anything else, please email us at customercare@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Luca Bertolaccini Academic Editor PLOS One |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .