Peer Review History
| Original SubmissionAugust 25, 2025 |
|---|
|
Dear Dr. ELAHE, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Jan 10 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org . When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols . We look forward to receiving your revised manuscript. Kind regards, Junhuang Jiang Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. We note that your Data Availability Statement is currently as follows: All relevant data are within the manuscript and Supporting Information files Please confirm at this time whether or not your submission contains all raw data required to replicate the results of your study. Authors must share the “minimal data set” for their submission. PLOS defines the minimal data set to consist of the data required to replicate all study findings reported in the article, as well as related metadata and methods (https://journals.plos.org/plosone/s/data-availability#loc-minimal-data-set-definition). For example, authors should submit the following data: - The values behind the means, standard deviations and other measures reported; - The values used to build graphs; - The points extracted from images for analysis. Authors do not need to submit their entire data set if only a portion of the data was used in the reported study. If your submission does not contain these data, please either upload them as Supporting Information files or deposit them to a stable, public repository and provide us with the relevant URLs, DOIs, or accession numbers. For a list of recommended repositories, please see https://journals.plos.org/plosone/s/recommended-repositories. If there are ethical or legal restrictions on sharing a de-identified data set, please explain them in detail (e.g., data contain potentially sensitive information, data are owned by a third-party organization, etc.) and who has imposed them (e.g., an ethics committee). Please also provide contact information for a data access committee, ethics committee, or other institutional body to which data requests may be sent. If data are owned by a third party, please indicate how others may request data access. 3. If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes Reviewer #4: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? -->?> Reviewer #1: No Reviewer #2: Yes Reviewer #3: Yes Reviewer #4: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available??> The PLOS Data policy Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes Reviewer #4: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English??> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes Reviewer #4: Yes ********** Reviewer #1: • The manuscript is well-structured but requires deeper justification for selecting only BRCA and ROSMAP datasets to validate generalizability. • Figures illustrating the experimental workflow and results could be improved with clearer legends and higher resolution for readability. • The discussion section should explicitly compare findings with recent graph-transformer and hypergraph models to contextualize novelty. • Parameter sensitivity analysis for α, β, and γ is missing and should be included to enhance reproducibility. • The comparison with state-of-the-art models is limited; include some recent work such as Feature selection using game Shapley improved grey wolf optimizer for optimizing cancer classification, A hybrid feature gene selection approach by integrating variance filter, extremely randomized tree, and Cuckoo Search algorithm for cancer classification, AI-driven insights: a machine learning approach to lung cancer diagnosis, Efficient gene selection for breast cancer classification using Brownian Motion Search Algorithm and Support Vector Machine, Hybrid Feature Selection Techniques Utilizing Soft Computing Methods for Classifying Microarray Cancer Data, Improved GA based Clustering with a New Selection Method for Categorical Dental Data, A Novel Technique for Image Captioning Based on Hierarchical Clustering and Deep Learning, Study of Optimality Strategies for Two-Person Game Model Under Interval Uncertainty. • The introduction could better emphasize the research gap and how this study advances beyond existing GCN-based multi-omics works. • The statistical validation (t-tests) should be complemented by effect size or confidence interval reporting to strengthen the results. • The authors may include an ablation study to show the individual contributions of GCN and VCDN components. • The manuscript would benefit from highlighting biological interpretability and practical implications of the results in clinical contexts. • The conclusion section should be condensed and focus more on key takeaways and limitations rather than re-summarizing results. • English language and grammar are generally good but could be polished for conciseness and clarity, especially in the methodology section. Reviewer #2: In this manuscript, Bin Hannan Siam and colleagues have independently evaluated the classification performance (accuracy) of six similarity network construction strategies, which are implemented in graph convolutional networks (GCNs), a graph-based deep learning approach, using two benchmark datasets, BRCA and ROSMAP. The authors conclude that Cosine Similarity, one of the six similarity network construction strategies mentioned above, outperforms the others by demonstrating the superior accuracy, F1 score, and AUC, with the lowest standard deviation across validation splits using GCNs constructed with multiple omics datasets, including mRNA expression, DNA methylation, and miRNA expression. Overall, this manuscript is well written and well structured, providing profound information about the theoretical rationales and the analytical workflow. The finding and the conclusion are straightforward and sound. In this circumstance, only several minor comments from my perspective are for consideration. Minor comments: 1. “(0,1]” is written at several places, including lines 271, 302, and Table 1. I cannot recall whether a hybrid of half parentheses and brackets brings a specific mathematical meaning. If not, please correct it. 2. Please provide the citation for the statement mentioned in line 274. 3. Line 434: Can the authors elaborate more about the choice of k equal to 5? Is it based on empirical observations, or have the authors tested other sizes of k? 4. Please provide a Table legend for Table 3, explaining the representation of TP (true positive?), TN, FP, FN, P, and R written in the formulas. Reviewer #3: General Comments: This manuscript presents a systematic evaluation of similarity-network construction strategies within a graph-based multi-omics classification framework. Overall, the study is clearly motivated and generally well written. The finding that the simple Cosine Similarity outperforms more complex RBF and hybrid metrics is significant and provides valuable, practical guidance for the field. But several issues regarding methodological clarity, redundancy in presentation, and justification of analytical choices should be addressed before the manuscript can be considered for publication. Specific Comments: 1. Line 118: The manuscript states that “five similarity network strategies” were evaluated, whereas in other parts six strategies are described (Cosine similarity, Cosine distance, RBF similarity, RBF distance, Hybrid similarity, Hybrid distance). 2. The Methods section describing the similarity metrics is excessively detailed and interrupts the flow. I recommend keeping the essential definitions and moving extended mathematical explanations or background text to the Supplementary Material. 3. The authors should clarify how the number of selected features (e.g., 1000 / 1000 / 503 for BRCA; 200 / 200 / 200 for ROSMAP) was determined. Have different feature counts been tested? How does the number of selected features influence model stability or accuracy? 4. Several tables duplicate information already shown in figures: Table 2 duplicates Fig. 3, Table 4 duplicates Fig. 5 and Fig. 6, Table 5, Fig. 8A, and Fig. 8B show highly overlapping content. I suggest removing the redundant tables or figures to improve readability. Fig. 7 does not add additional information beyond Fig. 5 and Fig. 6. If the authors want to keep it, including cross-validation variance, standard deviation, or confidence intervals would make the figure more meaningful. Otherwise, I suggest removing it. 5. It would be valuable for the authors to comment on whether certain similarity metrics work better for specific omics types (mRNA vs. methylation vs. miRNA). Different omics layers have distinct distributions and noise characteristics. Testing modality-specific similarity networks could provide additional insight. 6. Because the hybrid and RBF methods depend heavily on γ and weighting parameters, the manuscript should describe the tuning procedures, the search space used, and whether the tuning strategy was applied consistently across all datasets. 7. Although early stopping is used, 2,500 epochs is relatively high for small omics datasets. The authors could provide the average stopping epoch and include validation-loss curves in the supplementary materials. 8. Since six networks * three omics * cross-view training were performed, the authors should provide runtime comparisons and discuss the computational resources required. Reviewer #4: The manuscript presents a well-designed and interesting study. However, after careful consideration, I feel that the main focus of the research does not fully align with the scope of PLOS ONE. While the findings are valuable within its specific field, they do not sufficiently meet the journal’s criteria regarding broad scientific relevance. This is purely a matter of scope rather than the quality or significance of the study itself. I believe the manuscript may be better suited for a more specialized journal that focuses directly on this type of research. ********** what does this mean? ). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy Reviewer #1: No Reviewer #2: Yes: Heng-Chang Chen Reviewer #3: No Reviewer #4: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation. NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications. |
| Revision 1 |
|
Dear Dr. ELAHE, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Mar 16 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org . When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.
If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols . We look forward to receiving your revised manuscript. Kind regards, Junhuang Jiang Academic Editor PLOS One Journal Requirements: If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise. Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author Reviewer #1: All comments have been addressed Reviewer #2: All comments have been addressed Reviewer #3: (No Response) ********** 2. Is the manuscript technically sound, and do the data support the conclusions??> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? -->?> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available??> The PLOS Data policy Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English??> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** Reviewer #1: None,the authors have adequately addressed all the comments raised in the previous round of review. I find the revised manuscript acceptable for publication. Reviewer #2: The authors have carefully addressed all my comments. At this stage, I don't have any more comments, so I recommend this manuscript for publication. Reviewer #3: The authors have carefully considered and adequately addressed my main concerns from the previous round. The manuscript has improved substantially in clarity, organization, and methodological justification. At this stage, I have no major scientific concerns. My remaining comments mainly relate to presentation and redundancy. There is still considerable overlap in the information presented across multiple figures and tables, which affects the readability and conciseness of the manuscript. By implementing some consolidations, the core message—that Cosine Similarity is the most robust and accurate metric —will be supported by a much cleaner and more professional presentation. In particular, Figure 5 and Figure 6, both figures use three different visual formats (Radar plot, Violin plot, and Heatmap) to present the same set of performance metrics (Accuracy, F1, and AUC). Keep only one sub-figure (for example Figure 5C and 6C) per dataset is recommended. Tables 3 and 4 vs. Figures 5 and 6: Tables 3 and 4 provide Mean AUC, SD, and Cohen’s d. If the Heatmaps (5C/6C) are kept, consider moving the "Cohen’s d" and "95% CI" columns to the text or a supplementary table to avoid repeating the "Mean AUC" and "SD" values cross three different locations (Table, Figure Heatmap, and Supporting Information). Figure 7 presents the standard deviation of AUC using both a line plot (A) and a bar chart (B). I recommend keep only Figure 7B (Bar Chart). Ensure the numerical values from S3 Table (AUC standard deviation) are cited in the text so that the visual trend in Figure 7B is sufficient on its own. ********** what does this mean? ). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy Reviewer #1: No Reviewer #2: Yes: Heng-Chang Chen Reviewer #3: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation. NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications. |
| Revision 2 |
|
Effects of Similarity Networks in Graph-Based Multi-Omics Classification PONE-D-25-45745R2 Dear Dr. ELAHE, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. For questions related to billing, please contact billing support . If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Tao Huang Academic Editor PLOS One Additional Editor Comments (optional): Reviewers' comments: Reviewer's Responses to Questions Comments to the Author Reviewer #1: All comments have been addressed Reviewer #2: All comments have been addressed Reviewer #3: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions??> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? -->?> Reviewer #1: No Reviewer #2: Yes Reviewer #3: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available??> The PLOS Data policy Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English??> Reviewer #1: Yes Reviewer #2: (No Response) Reviewer #3: Yes ********** Reviewer #1: None, The manuscript presents a systematic and well-designed evaluation of similarity network construction strategies for graph-based multi-omics disease classification. The comparative analysis across BRCA and ROSMAP datasets is comprehensive and statistically sound. A key and interesting finding is that simple Cosine Similarity consistently outperforms more complex kernel-based and hybrid approaches in accuracy, stability, and robustness. The study highlights the importance of interpretability and simplicity in high-dimensional biological data modeling. No concerns regarding research ethics, data usage, or dual publication are observed. Reviewer #2: The authors have greatly improved the quality of this manuscript in terms of readability of the main text and figures. I do not have further comments and recommend publication at PLOS One. Reviewer #3: All of my previous concerns have been addressed satisfactorily, and I have no additional comments at this time. ********** what does this mean? ). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy Reviewer #1: No Reviewer #2: Yes: Heng-Chang Chen Reviewer #3: No ********** |
| Formally Accepted |
|
PONE-D-25-45745R2 PLOS One Dear Dr. ELAHE, I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS One. Congratulations! Your manuscript is now being handed over to our production team. At this stage, our production department will prepare your paper for publication. This includes ensuring the following: * All references, tables, and figures are properly cited * All relevant supporting information is included in the manuscript submission, * There are no issues that prevent the paper from being properly typeset You will receive further instructions from the production team, including instructions on how to review your proof when it is ready. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few days to review your paper and let you know the next and final steps. Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. You will receive an invoice from PLOS for your publication fee after your manuscript has reached the completed accept phase. If you receive an email requesting payment before acceptance or for any other service, this may be a phishing scheme. Learn how to identify phishing emails and protect your accounts at https://explore.plos.org/phishing. If we can help with anything else, please email us at customercare@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Tao Huang Academic Editor PLOS One |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .