Peer Review History
| Original SubmissionJune 23, 2025 |
|---|
|
Dear Dr. Otto, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Sep 21 2025 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org . When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols .. We look forward to receiving your revised manuscript. Kind regards, Kokouvi Kassegne Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. Thank you for stating the following financial disclosure: [TDO was supported by the ExposUM Institute of the University of Montpellier (grants ANR-21-EXES-0005 and Occitanie Region) and the Wellcome Trust: 104111/Z/14/Z & A. EAP was funded by La Caixa Foundation - Health Research Program (HR20-00635).]. Please state what role the funders took in the study. If the funders had no role, please state: """"The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript."""" If this statement is not correct you must amend it as needed. Please include this amended Role of Funder statement in your cover letter; we will change the online submission form on your behalf. 3. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information. 4. If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise. Additional Editor Comments: Please provide point-by-point response to the reviewers' comments and revise the manuscript accordingly to show where revisions have been made. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? -->?> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available??> The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.--> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English??> Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** Reviewer #1: Pangilinan et al present a new tool for predicting the upstream region classification of var genes encoding P .falciparum’s key virulence proteins , PfEMP1). This is important as the var genes, despite their extreme diversity generated though both recombination and mutation, are well organized in the genome with specific receptor-binding phenotypes linked to specific chromosomal locations and upstream regions. This has led reserachers to use these sequence signatures to link receptor binding phenotypes to clinical outcome, and speculate if also genetic regulation may be tied to e.g. parasites establishing low patent chronic “dry season “infections or fast switching at the eary onset of infection etc. The present tool for linking ups-type to gene fragments which can be extracted experimentally- most commonly and DBLa tags is a welcoming tool, not least as an earlier attempt for such a tool was considered highly inaccurate – a notion supported by the present analyses. A main challenge is within the biological limitations provided by the recombinogenic nature of the var genes.. ie the “truth” is that most likely not all var genes can be classified as either upsa, b or c – due to their recent recombination between the groups. As In addition to the upsABC the authors attempt to predict the chromosomal location from encoded sequence fragments, - again this may be inherently difficult for recently recombined genes. On this background the authors apply and compare three different computational approaches to tackle the classification. The reporting on this is sound hones and open about the limitations – which - as expected and supported by 2 examples of in-depth analysis of ups-type calling sequence elements tiled across the var sequence, - appear to reflect said biological limitations. It is this open and clear description of the limitations of the too, which makes the strength of the paper and will guide proper applications and data interpretations from the tool. I think this is well done. A key application will be the annotation of expressed DBLa tags as these are the most easily acquired through NGS. A challenge for using the tool is that it relies on protein sequence. Have the authors tried to apply raw error prone DBLa tag DNA sequences ? if this was possible this would omit need for cumbersome data curation of large DBLa tag datasets? In my view the use of DC is less likely to happen or be meaningful. The mention of domain cassettes (DCs) line 69 to 71, and throughout MS could be omitted as these have proven inaccurate and obsolete descriptions of both pfemp1 geno- and phenotypes. If kept i suggest some subtle changes below: Line 73: For instance, half of group A and some B variants (DC8) bind …, whereas group A and C variants bind CD36 and are… (ie remove “tend to”). Similarly the commonly used phrase "such as" on PfEMP1 endothelial receptors should changed as 1) it implies there is something grouping and common about CD36 EPCR and ICAM1 among endothelial receptors- there is not to my knowledge..2) also it implies some unspecific binding to a panel of receptors within ec receptors - this is not the case either..PfEMP1 have shown to be highly adapted to their human receptors. I suggest "via specific binding to host receptors including cd36, EPCR and ICAm1..." Line 64: strictly speaking: var2csa is not conserved .... Section from line 156: The use of "var" gene sequence regions is misleading as what was used is the translated pfemp1 (protein ) sequences. Reviewer #2: The authors address an important issue, the ability to infer further information about var gene sequences based on the partial sequences typically obtained from volunteer samples. This has value for evolutionary and genetics perspectives, attempting to understand the recombinations that underly the phylogeny of these gene family, and also may prove useful in identifying associations between var sequences and clinical phenotypes. Associations between ups types and severe disease have been frequently noted but remain unexplained, a robust means of predicting characteristics of these genes in the absence of the definitive upstream sequence data will allow such associations to be tested in larger datasets. The ultimate goal would be to predict the set of genes to which a tag or contig could belong and this work is a valuable step along that path. The developed tool has advantages and disadvantages compared to the already available cUPS namely upsAI classifies ups B better and cUPS classifies ups C better, this appears to be because upsAI claims more Cs as Bs and cUPS claims more Bs as Cs. As the authors note this difference affects accuracy due to the greater number of B than C genes in the genome. Combining the two approaches would enable a relatively stringent set of identifications to be made but would leave a large number of genes as either upsC or B. The authors made the interesting biological observations that he tools worked best on models that segregated genes by their chromosome position rather than by ups B/C. This suggests that constrained recombination due to genomic location has segregated the coding sequences for chromosomal internal upsB despite the homology between upsB sequences from telomeres or internal sites. Their tag analysis further substantiates this showing that tags can be associated with another ups type than the actual gene they belong to, presumably due to recombination. Overall this paper makes a useful contribution providing a novel tool for var gene classification and using it to make several interesting observations about var gene recombination that inform our understanding of the gene family’s evolution. I have only 2 minor suggestions, Line 22 “the best model of upsAI for DBLα-tags sequences achieves an overall accuracy of 83%, 92% and for full-length PfEMP1 sequences, therefore significantly outperforming existing tools.” There appears to be a typo in this sentence Lines 388-391 “However, we advise caution in interpreting these patterns, as the underlying dataset is subject to biases related to sequencing quality and assembly methods. To draw robust biological conclusions regarding var gene distributions, more controlled datasets, such as RNA-Seq-derived contigs from clinical isolates stratified by disease phenotype, would be necessary. “ Why would rnaseq be more informative about var distributions? Presumably not all the var repertoire would be expressed and there are more likely to issues with uneven 5' coverage from rnaseq. Clinical rnaseq would allow associations between ups type and clinical disease to be identfied. Could the authors clarify what they mean by this statement. Reviewer #3: Please see attached review. ----------------------------------------------------------------------- ********** what does this mean? ). If published, this will include your full peer review and any attached files.). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our For information about this choice, including consent withdrawal, please see our Privacy Policy .--> Reviewer #1: No Reviewer #2: No Reviewer #3: Yes: Yao-ban ChanYao-ban Chan ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/ . PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at . PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org . Please note that Supporting Information files do not need this step.. Please note that Supporting Information files do not need this step.
|
| Revision 1 |
|
Dear Dr. Otto Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. ============================== Please submit your revised manuscript by Dec 25 2025 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org . When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.
If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols .. We look forward to receiving your revised manuscript. Kind regards, Kokouvi Kassegne Academic Editor PLOS ONE Journal Requirements: If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise. Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. Additional Editor Comments : Please provide point-by-point to to the reviewer's minor comments and revise the manuscript accordingly to show (in tracking change mode) where revisions are made. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author Reviewer #1: All comments have been addressed Reviewer #2: All comments have been addressed Reviewer #3: (No Response) ********** 2. Is the manuscript technically sound, and do the data support the conclusions??> Reviewer #1: Yes Reviewer #2: (No Response) Reviewer #3: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? -->?> Reviewer #1: Yes Reviewer #2: (No Response) Reviewer #3: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available??> The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.--> Reviewer #1: Yes Reviewer #2: (No Response) Reviewer #3: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English??> Reviewer #1: Yes Reviewer #2: (No Response) Reviewer #3: Yes ********** Reviewer #1: The authors have addressed all my comments appropriately and made changes to the manuscript accordingly. Reviewer #2: (No Response) Reviewer #3: Please see attached pdf. I include some filler words here to attain the lower character limit. (This is a rather absurd requirement.) ********** what does this mean? ). If published, this will include your full peer review and any attached files.). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our For information about this choice, including consent withdrawal, please see our Privacy Policy .--> Reviewer #1: No Reviewer #2: No Reviewer #3: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation. NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications.
|
| Revision 2 |
|
Dear Dr. Thomas D Otto, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Mar 04 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org . When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.
If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols .. We look forward to receiving your revised manuscript. Kind regards, Kokouvi Kassegne Academic Editor PLOS One Journal Requirements: If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise. Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. Additional Editor Comments: Minor revisions are requested; please refer to the attachment [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author Reviewer #3: (No Response) ********** 2. Is the manuscript technically sound, and do the data support the conclusions??> Reviewer #3: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? -->?> Reviewer #3: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available??> The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.--> Reviewer #3: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English??> Reviewer #3: Yes ********** Reviewer #3: Please see attached review. ----------------------------------------------------------------------- ********** what does this mean? ). If published, this will include your full peer review and any attached files.). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our For information about this choice, including consent withdrawal, please see our Privacy Policy .--> Reviewer #3: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation. NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications.
|
| Revision 3 |
|
upsML: A high-accuracy machine learning classifier for predicting Plasmodium falciparum var gene upstream groups PONE-D-25-33506R3 Dear Dr. Thomas D Otto, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. For questions related to billing, please contact and clicking the ‘Update My Information' link at the top of the page. For questions related to billing, please contact billing support .. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Kokouvi Kassegne Academic Editor PLOS One Additional Editor Comments (optional): The authors have satisfactorily addressed all the comments. Two minor typos: Fig 4 still has "AUC" l599 "extract weights from" Reviewers' comments: Reviewer's Responses to Questions Comments to the Author Reviewer #3: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions??> Reviewer #3: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? -->?> Reviewer #3: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available??> The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.--> Reviewer #3: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English??> Reviewer #3: Yes ********** Reviewer #3: The authors have satisfactorily addressed my comments. Two minor typos: Fig 4 still has "AUC" l599 "extract weights from" ********** what does this mean? ). If published, this will include your full peer review and any attached files.). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our For information about this choice, including consent withdrawal, please see our Privacy Policy .--> Reviewer #3: No ********** |
| Formally Accepted |
|
PONE-D-25-33506R3 PLOS One Dear Dr. Otto, I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS One. Congratulations! Your manuscript is now being handed over to our production team. At this stage, our production department will prepare your paper for publication. This includes ensuring the following: * All references, tables, and figures are properly cited * All relevant supporting information is included in the manuscript submission, * There are no issues that prevent the paper from being properly typeset You will receive further instructions from the production team, including instructions on how to review your proof when it is ready. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few days to review your paper and let you know the next and final steps. Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. You will receive an invoice from PLOS for your publication fee after your manuscript has reached the completed accept phase. If you receive an email requesting payment before acceptance or for any other service, this may be a phishing scheme. Learn how to identify phishing emails and protect your accounts at https://explore.plos.org/phishing. If we can help with anything else, please email us at customercare@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Kokouvi Kassegne Academic Editor PLOS One |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .