Peer Review History

Original SubmissionNovember 2, 2025
Decision Letter - Mengistu Zenebe, Editor

-->PONE-D-25-58950-->-->Microbiological quality assessment of potential pathogenic bacteria and multidrug resistance patterns in commercial electrolyte drinks in Dhaka, Bangladesh-->-->PLOS One

Dear Dr. Haque,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

Please submit your revised manuscript by Jan 23 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:-->

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Mengistu Hailemariam Zenebe, PhD

Academic Editor

PLOS One

Journal Requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

-->Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. -->

Reviewer #1: No

Reviewer #2: Yes

**********

-->2. Has the statistical analysis been performed appropriately and rigorously? -->

Reviewer #1: No

Reviewer #2: Yes

**********

-->3. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.-->

Reviewer #1: No

Reviewer #2: Yes

**********

-->4. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.-->

Reviewer #1: No

Reviewer #2: Yes

**********

-->5. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)-->

Reviewer #1: The authors conducted this study to determine the presence and antimicrobial resistance profiles of various Gram-positive and Gram-negative bacteria isolated from local electrolytes in Bangladesh. This study seems interesting, but I found a lot of serious drawbacks! I believe the authors should check the CLSI guidelines properly before selecting antibiotics against different bacteria. Moreover, I found some serious issues in the AMR results. For example, Klebsiella pneumoniae is intrinsically resistant to ampicillin, amoxicillin, amoxicillin-clavulanic acid, and cefoxitin, but they found 30.77%, 19.23%, 3.85%, and 15.38% of the isolates, respectively. This result doesn’t make sense. The same happened to Pseudomonas aeruginosa, Acinetobacter baumannii, and others. Moreover, you mustn’t follow CLSI 2018 for Vibrio isolates; you should follow CLSI 2015. Also, you used the disk diffusion test for vancomycin, but you mustn’t do that. You must determine MIC values for Staphylococcus aureus against vancomycin to determine their resistance profiles. Overall, I feel the authors didn’t conduct the study properly. They should repeat the study with a proper study design and antimicrobial agent selection. They should also properly evaluate the lab work and results to maintain scientific integrity.

Reviewer #2: The article describe the "Microbiological quality assessment of potential pathogenic bacteria and multidrug

resistance patterns in commercial electrolyte drinks in Dhaka, Bangladesh". The article is well written with sufficient data and the results are convincing. However, the author should consider the following points before finalizing the manuscript.

1. The author isolated a number of bacteria from different samples. the author should add the images of grams staining as well as the characteristic colony of the isolated bacteria in the supplementary materials.

2. It would be good to to show Antimicrobial Resistance (AMR) using heat maps, and this is a widely used and effective method in scientific research and public health surveillance. Heat maps provide a clear visual representation of complex AMR data, allowing researchers and public health officials to identify patterns, trends, and correlations easily.

3. Discuss the production volume and popularity of electrolyte drink in Bangladesh in the introduction section of the manuscript.

4. The authors identified antibiotic resistance only phenotypically, the authors can target known genes responsible for that resistance mechanism.

For Methicillin-resistant Staphylococcus aureus (MRSA): The primary target is the mecA or mecC gene, which encodes penicillin-binding protein 2a (PBP2a), conferring resistance to methicillin and most beta-lactams.

For Extended-Spectrum Beta-Lactamase (ESBL) producers (common in E. coli and Klebsiella): Common genes to screen for include blaCTX-M, blaTEM, and blaSHV subclasses.

For Carbapenem-resistant Gram-negative bacteria: Key carbapenemase genes include blaKPC, blaNDM, blaVIM, blaIMP, and blaOXA-48-like.

For Tetracycline resistance: Common genes are tetA, tetB, tetM, etc.

Data regarding the resistance mechanism will improve the quality of the manuscripts and would be more acceptable to the readers.

**********

-->6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.-->

Reviewer #1: Yes: Md Saiful Islam

Reviewer #2: Yes: Sukumar Saha

**********

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures

You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation.

NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications.

Revision 1

We extend our heartfelt appreciation to the reviewers and editors for their invaluable critiques and suggestions, which have significantly contributed to the enhancement of our manuscript. In response to the reviewers’ feedback, we have carefully revised the manuscript by updating and expanding the reference list, adding new results, including a heatmap illustrating antimicrobial resistance patterns, and incorporating a new figure (heatmap) and an additional table summarizing antimicrobial resistance–related genes. We have prepared a rebuttal letter that responds to each point raised by the academic editor and reviewer(s) and uploaded the letter as a separate file labeled as “Response to Reviewers” along with all other associated files.

Attachments
Attachment
Submitted filename: Response to Reviewers.docx
Decision Letter - Mengistu Zenebe, Editor

-->PONE-D-25-58950R1-->-->Microbiological quality assessment of potential pathogenic bacteria and multidrug resistance patterns in commercial electrolyte drinks in Dhaka, Bangladesh-->-->PLOS One

Dear Dr. Haque,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

Please submit your revised manuscript by Jun 12 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:-->

  • A letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

-->

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

As the corresponding author, your ORCID iD is verified in the submission system and will appear in the published article. PLOS supports the use of ORCID, and we encourage all coauthors to register for an ORCID iD and use it as well. Please encourage your coauthors to verify their ORCID iD within the submission system before final acceptance, as unverified ORCID iDs will not appear in the published article. Only the individual author can complete the verification step; PLOS staff cannot verify ORCID iDs on behalf of authors.

We look forward to receiving your revised manuscript.

Kind regards,

Mengistu Hailemariam Zenebe, PhD

Academic Editor

PLOS One

Journal Requirements:

If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise.

Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

-->Comments to the Author

1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation.-->

Reviewer #3: (No Response)

Reviewer #4: All comments have been addressed

**********

-->2. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. -->

Reviewer #3: Yes

Reviewer #4: Yes

**********

-->3. Has the statistical analysis been performed appropriately and rigorously? -->

Reviewer #3: Yes

Reviewer #4: Yes

**********

-->4. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.-->

Reviewer #3: Yes

Reviewer #4: Yes

**********

-->5. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.-->

Reviewer #3: Yes

Reviewer #4: Yes

**********

-->6. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)-->

Reviewer #3: (No Response)

Reviewer #4: The authors mostly addressed the raised concnerns. Before the manuscript acceptance, they must carefully revise the italics writing of the scientific name of species within the entire manuscript, including figures and newly inserted references.

**********

-->7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.-->

Reviewer #3: No

Reviewer #4: No

**********

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures

You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation.

NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications.

-->

Attachments
Attachment
Submitted filename: PONE-D-25-58950 Reviewers Comments.docx
Revision 2

In response to the reviewers’ feedback, we have carefully revised the manuscript by updating and expanding the reference list, supporting all the relevant data with proper reference in the manuscript, adding all the methodological details and clarifications requested by the reviewers in the Methods section and shortening the introduction and discussion section to fit the structured narrative of a research manuscript. Furthermore, the overall language and clarity of the manuscript have been improved in accordance with the reviewers’ recommendations. We are confident that these revisions have strengthened our manuscript.

Attachments
Attachment
Submitted filename: Response to the Reviewers.docx
Decision Letter - Mengistu Zenebe, Editor

Microbiological quality assessment of potential pathogenic bacteria and multidrug resistance patterns in commercial electrolyte drinks in Dhaka, Bangladesh

PONE-D-25-58950R2

Dear Author,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. For questions related to billing, please contact billing support.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Mengistu Hailemariam Zenebe, PhD

Academic Editor

PLOS One

Additional Editor Comments (optional):

Reviewers' comments:

Formally Accepted
Acceptance Letter - Mengistu Zenebe, Editor

PONE-D-25-58950R2

PLOS One

Dear Dr. Haque,

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS One. Congratulations! Your manuscript is now being handed over to our production team.

At this stage, our production department will prepare your paper for publication. This includes ensuring the following:

* All references, tables, and figures are properly cited

* All relevant supporting information is included in the manuscript submission,

* There are no issues that prevent the paper from being properly typeset

You will receive further instructions from the production team, including instructions on how to review your proof when it is ready. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few days to review your paper and let you know the next and final steps.

Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

You will receive an invoice from PLOS for your publication fee after your manuscript has reached the completed accept phase. If you receive an email requesting payment before acceptance or for any other service, this may be a phishing scheme. Learn how to identify phishing emails and protect your accounts at https://explore.plos.org/phishing.

If we can help with anything else, please email us at customercare@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff

on behalf of

Dr. Mengistu Hailemariam Zenebe

Academic Editor

PLOS One

Open letter on the publication of peer review reports

PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.

We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.

Learn more at ASAPbio .