Peer Review History
| Original SubmissionNovember 6, 2024 |
|---|
|
PONE-D-24-50441The critical role of optimized energy density in controlling void morphology and enhancing mechanical properties of L-PBF Ti-6Al-4V ELI alloyPLOS ONE Dear Dr. Srimaneepong, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please, improve the description of the methods and also the discussion of the results. More detailed analysis of the results is required. More results can be extracted from microCT as pointed out by reviewers. Please submit your revised manuscript by Feb 09 2025 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org . When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols . We look forward to receiving your revised manuscript. Kind regards, Antonio Riveiro Rodríguez, PhD Academic Editor PLOS ONE Journal requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. Thank you for stating the following financial disclosure: “The Faculty of Dentistry, Chulalongkorn University (grant no: DF65003) and the National Research Council of Thailand (NRCT) (grant no: N23A650883).” Please state what role the funders took in the study. If the funders had no role, please state: "The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript." If this statement is not correct you must amend it as needed. Please include this amended Role of Funder statement in your cover letter; we will change the online submission form on your behalf. 3. Thank you for stating the following in the Acknowledgments Section of your manuscript: “This work was supported by the Faculty of Dentistry, Chulalongkorn University (grant no: DF65003) and the National Research Council of Thailand (NRCT) (grant no:N23A650883). The authors appreciate the support from Dr. Ammarueda Issariyapat and Horiba (Thailand) for ONH analysis. Aung Nyein Soe acknowledges the financial support from King Mongkut’s University of Technology Thonburi under the industrial Post-Doctoral and Post-Master program.” We note that you have provided funding information that is currently declared in your Funding Statement. However, funding information should not appear in the Acknowledgments section or other areas of your manuscript. We will only publish funding information present in the Funding Statement section of the online submission form. Please remove any funding-related text from the manuscript and let us know how you would like to update your Funding Statement. Currently, your Funding Statement reads as follows: “The Faculty of Dentistry, Chulalongkorn University (grant no: DF65003) and the National Research Council of Thailand (NRCT) (grant no: N23A650883).” Please include your amended statements within your cover letter; we will change the online submission form on your behalf. 4. Please update your submission to use the PLOS LaTeX template. The template and more information on our requirements for LaTeX submissions can be found at http://journals.plos.org/plosone/s/latex. 5. In the online submission form, you indicated that [Data will be made available on request]. All PLOS journals now require all data underlying the findings described in their manuscript to be freely available to other researchers, either 1. In a public repository, 2. Within the manuscript itself, or 3. Uploaded as supplementary information. This policy applies to all data except where public deposition would breach compliance with the protocol approved by your research ethics board. If your data cannot be made publicly available for ethical or legal reasons (e.g., public availability would compromise patient privacy), please explain your reasons on resubmission and your exemption request will be escalated for approval. 6. Please amend either the title on the online submission form (via Edit Submission) or the title in the manuscript so that they are identical. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Partly Reviewer #2: No ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: No ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: No ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: Paper ‘The critical role of optimized energy density in controlling void morphology and enhancing mechanical properties of L-PBF Ti-6Al-4V ELI alloy’ presents an interesting topic related to optimal processing parameters and laser additive manufacturing. The influence of laser power on defects, microstructure and mechanical behavior of L-PBF fabricated TC4 alloy was studied. There's been a lot of researches on this field, and some questions should be added to improve the quality of the manuscript. 1. The parameters that determine the density of laser energy are laser power and scanning speed, hatch spacing and layer thickness. There is no clear explanation for why only the laser power is indicated as a variable in Introduction. Also, the authors did not explain why the laser scanning speed of 1200 mm/s, layer thickness of 20 µm, hatch spacing of 110 µm, laser spot size of 30 µm a were selected in section of Materials and Methods. 2. The laser spot 30 µm was used in this paper, and it is not the same as the commonly used fiber laser with spot size of 70-100 µm. The authors should indicate the type and wavelength of the laser used in section of Materials and sample preparation. 3. The shape and size of tensile samples should give in section of Mechanical testing. 4. The oxygen, nitrogen, and hydrogen contents obviously increase with the increase of laser power. The author should explain the cause of this phenomenon. 5. In Void defect analysis, the authors only analyzed the variation trend of laser power on the morphology and size of defects. It is also important for authors to provide a specific value for the size change. Furthermore, I believe that the described defect characteristics based on CT examination are not sufficient in this paper, and that the author should provide a more detailed description of defect characteristics and the correlation between these defects and process parameters. 6. From Fig.5, the elongation of as-built samples is highest for the 100 W, and the tensile strength is highest for the 150 W. As stated in the article, the defects of the formed parts are at their lowest at 100W, however, the tensile strength is not the highest at this time. This indicates that the microstructure also has a great influence on the mechanical properties. It is necessary for the authors to explain the cause of mechanical properties change, combined with the change of microstructure as a result of laser power. Reviewer #2: Thank you for your article. There are a number of inadequecies that will need to be addressed before this is at an acceptable quality level to be publishable. The description of the manufacture of the samples needs significant improvement, detailing all the samples manufactured, their sizes, number off etc for each of the tests performed in their analysis. The testing methods need to be more detailed to provide details of the sampling methods used to provide statistical robustness. Also, any stated value must have an associated error value stated. The xCT software should be utilised in the analysis to extract useful information regarding the pores, including e.g. pore volume, pore size distributions, pore geometries (average roundness, average axis dimensions), etc. There is a lot of valuable data possible from xCT that you are not using. There appears to be discrepancy between the results in Fig 3 and those in Fig 4. This needs to be explained. The discussion of the results is quite limited and needs improvement, with further analysis of the data required. Some conclusions and hypotheses are made that are unsubstantiated by the results as they stand and more detailed analysis of the results, and further sample analysis (advanced SEM techniques) will be required to be able to substantiate these. These and more trivial errors are detailed in the attachment. ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean? ). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy . Reviewer #1: Yes: Pei Wei Reviewer #2: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/ . PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org . Please note that Supporting Information files do not need this step.
|
| Revision 1 |
|
PONE-D-24-50441R1The critical role of optimized energy density in controlling void morphology and enhancing mechanical properties of L-PBF Ti-6Al-4V ELI alloyPLOS ONE Dear Dr. Srimaneepong, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please, address the minor comments given by reviewer 2 (please, improve the presentation of the errors) and 4. Please submit your revised manuscript by Mar 29 2025 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org . When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols . We look forward to receiving your revised manuscript. Kind regards, Antonio Riveiro Rodríguez, PhD Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #2: All comments have been addressed Reviewer #3: All comments have been addressed Reviewer #4: (No Response) ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #2: Yes Reviewer #3: Yes Reviewer #4: (No Response) ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #2: Yes Reviewer #3: Yes Reviewer #4: (No Response) ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #2: Yes Reviewer #3: Yes Reviewer #4: (No Response) ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #2: Yes Reviewer #3: Yes Reviewer #4: (No Response) ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #2: Errors are now provided with results, but they need to be presented to the appropriate level of precision. E.g. P28, 12.772±1.394 um, should be written as 13±1, 7.631±0.265 should be written as 7.6±0.3 etc. Please amend this throughout. Table 1 P29 still requires an assessment of error in the wt% values. P32 No assessment of error in the dimensions of the voids. All these dimensions require an error value. Without that you cannot assess if the changes between samples is statistically significant. Reviewer #3: the authors have addressed all of my comments in the revised version, and I have accepted the manuscript in its current form Reviewer #4: Manuscript Number: PONE-D-24-50441R1 Manuscript Title: The critical role of optimized energy density in controlling void morphology and enhancing mechanical properties of L-PBF Ti-6Al-4V ELI alloy 1. The abstract is perfect. 2. It is better to provide references for formulas and equations. 3. Increase the quality of Figure 1. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean? ). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy . Reviewer #2: Yes: Prof Gregory J Gibbons Reviewer #3: Yes: Zameer Abbas, PhD scholar in the School of Statistics East China Normal University, Shanghai, China. Reviewer #4: Yes: Behnam Akhoundi ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/ . PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org . Please note that Supporting Information files do not need this step. |
| Revision 2 |
|
PONE-D-24-50441R2The critical role of optimized energy density in controlling void morphology and enhancing mechanical properties of L-PBF Ti-6Al-4V ELI alloyPLOS ONE Dear Dr. Srimaneepong, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please see the appended Comments from Editorial Office. Please submit your revised manuscript by Jun 08 2025 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org . When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols . We look forward to receiving your revised manuscript. Kind regards, Antonio Riveiro Rodríguez, PhD Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. Additional Editor Comments: Comments from Editorial Office : Please further address the most recent comments of Reviewer #2 regarding quotation of values and associated uncertainties: "Errors are now provided with results, but they need to be presented to the appropriate level of precision. E.g. P28, 12.772±1.394 um, should be written as 13±1, 7.631±0.265 should be written as 7.6±0.3 etc". Throughout the manuscript, uncertainties should be quoted to 1 significant figure and associated values quoted to this same precision. [Note: HTML markup is below. Please do not edit.] [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/ . PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org . Please note that Supporting Information files do not need this step. |
| Revision 3 |
|
The critical role of optimized energy density in controlling void morphology and enhancing mechanical properties of L-PBF Ti-6Al-4V ELI alloy PONE-D-24-50441R3 Dear Dr. Srimaneepong, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. If you have any questions relating to publication charges, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Antonio Riveiro Rodríguez, PhD Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: |
| Formally Accepted |
|
PONE-D-24-50441R3 PLOS ONE Dear Dr. Srimaneepong, I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now being handed over to our production team. At this stage, our production department will prepare your paper for publication. This includes ensuring the following: * All references, tables, and figures are properly cited * All relevant supporting information is included in the manuscript submission, * There are no issues that prevent the paper from being properly typeset You will receive further instructions from the production team, including instructions on how to review your proof when it is ready. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few days to review your paper and let you know the next and final steps. Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. If we can help with anything else, please email us at customercare@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Antonio Riveiro Rodríguez Academic Editor PLOS ONE |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .