| Original SubmissionSeptember 25, 2024 |
|---|
|
PONE-D-24-42025Electroacupuncture for acute postoperative pain after video-assisted thoracoscopic surgery: study protocol for a pilot randomized controlled trialPLOS ONE Dear Dr. Tu, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Nov 23 2024 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org . When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols . We look forward to receiving your revised manuscript. Kind regards, Hantong Hu Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. We note that the grant information you provided in the ‘Funding Information’ and ‘Financial Disclosure’ sections do not match. When you resubmit, please ensure that you provide the correct grant numbers for the awards you received for your study in the ‘Funding Information’ section. 3. We note that you have indicated that there are restrictions to data sharing for this study. For studies involving human research participant data or other sensitive data, we encourage authors to share de-identified or anonymized data. However, when data cannot be publicly shared for ethical reasons, we allow authors to make their data sets available upon request. For information on unacceptable data access restrictions, please see http://journals.plos.org/plosone/s/data-availability#loc-unacceptable-data-access-restrictions. Before we proceed with your manuscript, please address the following prompts: a) If there are ethical or legal restrictions on sharing a de-identified data set, please explain them in detail (e.g., data contain potentially identifying or sensitive patient information, data are owned by a third-party organization, etc.) and who has imposed them (e.g., a Research Ethics Committee or Institutional Review Board, etc.). Please also provide contact information for a data access committee, ethics committee, or other institutional body to which data requests may be sent. b) If there are no restrictions, please upload the minimal anonymized data set necessary to replicate your study findings to a stable, public repository and provide us with the relevant URLs, DOIs, or accession numbers. Please see http://www.bmj.com/content/340/bmj.c181.long for guidelines on how to de-identify and prepare clinical data for publication. For a list of recommended repositories, please see https://journals.plos.org/plosone/s/recommended-repositories. You also have the option of uploading the data as Supporting Information files, but we would recommend depositing data directly to a data repository if possible. Please update your Data Availability statement in the submission form accordingly. 4. We note that Figure 4 in your submission contain copyrighted images. All PLOS content is published under the Creative Commons Attribution License (CC BY 4.0), which means that the manuscript, images, and Supporting Information files will be freely available online, and any third party is permitted to access, download, copy, distribute, and use these materials in any way, even commercially, with proper attribution. For more information, see our copyright guidelines: http://journals.plos.org/plosone/s/licenses-and-copyright. We require you to either (1) present written permission from the copyright holder to publish these figures specifically under the CC BY 4.0 license, or (2) remove the figures from your submission: a. You may seek permission from the original copyright holder of Figure 4 to publish the content specifically under the CC BY 4.0 license. We recommend that you contact the original copyright holder with the Content Permission Form (http://journals.plos.org/plosone/s/file?id=7c09/content-permission-form.pdf) and the following text: “I request permission for the open-access journal PLOS ONE to publish XXX under the Creative Commons Attribution License (CCAL) CC BY 4.0 (http://creativecommons.org/licenses/by/4.0/). Please be aware that this license allows unrestricted use and distribution, even commercially, by third parties. Please reply and provide explicit written permission to publish XXX under a CC BY license and complete the attached form.” Please upload the completed Content Permission Form or other proof of granted permissions as an "Other" file with your submission. In the figure caption of the copyrighted figure, please include the following text: “Reprinted from [ref] under a CC BY license, with permission from [name of publisher], original copyright [original copyright year].” b. If you are unable to obtain permission from the original copyright holder to publish these figures under the CC BY 4.0 license or if the copyright holder’s requirements are incompatible with the CC BY 4.0 license, please either i) remove the figure or ii) supply a replacement figure that complies with the CC BY 4.0 license. Please check copyright information on all replacement figures and update the figure caption with source information. If applicable, please specify in the figure caption text when a figure is similar but not identical to the original image and is therefore for illustrative purposes only. 5. Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Does the manuscript provide a valid rationale for the proposed study, with clearly identified and justified research questions? The research question outlined is expected to address a valid academic problem or topic and contribute to the base of knowledge in the field. Reviewer #1: Yes Reviewer #2: Yes ********** 2. Is the protocol technically sound and planned in a manner that will lead to a meaningful outcome and allow testing the stated hypotheses? The manuscript should describe the methods in sufficient detail to prevent undisclosed flexibility in the experimental procedure or analysis pipeline, including sufficient outcome-neutral conditions (e.g. necessary controls, absence of floor or ceiling effects) to test the proposed hypotheses and a statistical power analysis where applicable. As there may be aspects of the methodology and analysis which can only be refined once the work is undertaken, authors should outline potential assumptions and explicitly describe what aspects of the proposed analyses, if any, are exploratory. Reviewer #1: Partly Reviewer #2: Yes ********** 3. Is the methodology feasible and described in sufficient detail to allow the work to be replicable? Descriptions of methods and materials in the protocol should be reported in sufficient detail for another researcher to reproduce all experiments and analyses. The protocol should describe the appropriate controls, sample size calculations, and replication needed to ensure that the data are robust and reproducible. Reviewer #1: No Reviewer #2: Yes ********** 4. Have the authors described where all data underlying the findings will be made available when the study is complete? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception, at the time of publication. The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: No Reviewer #2: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: No Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above and, if applicable, provide comments about issues authors must address before this protocol can be accepted for publication. You may also include additional comments for the author, including concerns about research or publication ethics. You may also provide optional suggestions and comments to authors that they might find helpful in planning their study. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: This manuscript reports on the protocol of a randomised sham-controlled trial of electroacupuncture for acute postoperative pain after video-assisted thoracoscopic surgery. While this manuscript provides details of study plans, there seem to be several points to be clarified or modified. 1)As the authors calculated a sample size and defined a primary outcome to conduct a formal statistical analysis to evaluate effect size of the intervention, it is not a pilot study. It’s not a pilot study simply because the sample size is small. 2)Since it is a sham-controlled trial protocol, I would like the authors to report on detailed wording given to participants regarding sham. Were the participants aware of the existence of sham electroacupuncture and that they may be randomly allocated to either real or fake intervention? This information about whether the term ‘fake’, ‘placebo’, ‘dummy’ or ‘sham’ was used in the informed consent process is important in the aspects of participant blinding and the direction of trial outcomes. 3)As per author guidelines of this journal, authors of protocols without data are strongly encouraged to state how they plan to share their data when it is completed or published. Stating ‘No datasets were generated or analysed during the current study. All relevant data from this study will be made available upon study completion’ does not give any information how data will be shared. Please state your plan how to share your data. Are your going to use publicly accessable link, or provide supplementary files of raw data/analytic codes? 4)I would like to reconsider “average” postoperative pain as a primary outcome. Usually pain intensity data measured with NRS or VAS are not normally distributed. It means that it is common that you get (almost) complete pain relief or (almost) no help at all. It is highly likely that you belong to either end of the NRS, good or bad. So if you use the “mean” data, you are using nobody’s result. So in acute pain trials, it is appropriate to use responder/non-responder analysis and I recommend you reconsider adopting this approach and recalcuating the sample size accordingly. 5)Please report datails about how you will assess participant blinding. Why are you going to evaluate blinding after the ‘2nd’ treatment, not after 1st or at the end of treatment? What is your rationale for selecting ‘after the 2nd treatment’? How many options are your going to give? Real or sham? Or Real, sham, or don’t know? Are you going to calculate blinding index and what statistical method are you going to use? All these information will be useful and you’ve got a plenty of space for such information as this is a protocol paper. 6)Page 5, lines 79-81: "It is unclear that the efficacy of electroacupuncture in alleviating acute postoperative pain after VATS." It's grammatically incorrect. Reviewer #2: It is interesting that authors designed a clinical trial to evaluate the efficacy of electroacupuncture in acute postoperative pain during coughing after video-assisted thoracoscopic surgery, I think several concerns listed below will need to be addressed to improve paper quality. 1. The primary outcome is the average postoperative pain score during coughing. Please revise the title to match the primary outcome. 2. Please provide the rationale for the treatment acupoints selection in the discussion section. 3. The primary outcome is the average postoperative pain score during coughing, measured using a numeric rating scroe in the Abstract section(line 36-38, page 2). However, it is measured using the PCIA in the Outcomes section (line 242- 245). Which is correct? 4. When is the evaluation time point for the primary endpoint? (at 24h or 48h or 72h after surgery) Please clarify it. 5. Is the primary outcome the changes in NRS at each timepoint? Is the secondary outcome the changes in secondary outcome at each timepoint? Please clarify it. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean? ). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy . Reviewer #1: Yes: Hyangsook Lee Reviewer #2: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/ . PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org . Please note that Supporting Information files do not need this step. |
| Revision 1 |
|
PONE-D-24-42025R1Electroacupuncture for acute postoperative pain during coughing after video-assisted thoracoscopic surgery : study protocol for a pilot randomized controlled trialPLOS ONE Dear Dr. Tu, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Jan 13 2025 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org . When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols . We look forward to receiving your revised manuscript. Kind regards, Hantong Hu Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. Additional Editor Comments: The comments of two reviewers have been addressed, and the quality of the manuscript has been significantly improved, but there are still two issues that need further elaboration. 1. The article only briefly mentions the assessment of whether blinding was successful for the patients: "The James' blinding indices will be used to assess the adequacy of blinding." Please provide more specific relevant details and references of the James' blinding indices. Notably, the Bang's blinding index is also a commonly used method in the field of sham acupuncture to assess whether patient blinding was successful. Please clarify the differences between the two methods and explain why you ultimately chose the James' blinding indices over the Bang's blinding index. 2. In the revised manuscript, "a responder is defined as a participant with an NRS score ≤ 4 when coughing" (at Lines 264-266). However, the baseline NRS score of patients will also impact the post-treatment score. Why not define a responder based on a certain threshold of change in NRS score before and after treatment? [Note: HTML markup is below. Please do not edit.] [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/ . PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org . Please note that Supporting Information files do not need this step. |
| Revision 2 |
|
PONE-D-24-42025R2Electroacupuncture for acute postoperative pain during coughing after video-assisted thoracoscopic surgery : study protocol for a pilot randomized controlled trialPLOS ONE Dear Dr. Tu, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Feb 13 2025 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org . When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols . Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols . We look forward to receiving your revised manuscript. Kind regards, Hantong Hu Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. Additional Editor Comments: As requested by the Editorial Office of Plos One, this paper must include a review by a statistical expert. Please make minor revisions to the manuscript based on this statistical expert’s comments. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Does the manuscript provide a valid rationale for the proposed study, with clearly identified and justified research questions? The research question outlined is expected to address a valid academic problem or topic and contribute to the base of knowledge in the field. Reviewer #3: Yes ********** 2. Is the protocol technically sound and planned in a manner that will lead to a meaningful outcome and allow testing the stated hypotheses? The manuscript should describe the methods in sufficient detail to prevent undisclosed flexibility in the experimental procedure or analysis pipeline, including sufficient outcome-neutral conditions (e.g. necessary controls, absence of floor or ceiling effects) to test the proposed hypotheses and a statistical power analysis where applicable. As there may be aspects of the methodology and analysis which can only be refined once the work is undertaken, authors should outline potential assumptions and explicitly describe what aspects of the proposed analyses, if any, are exploratory. Reviewer #3: Partly ********** 3. Is the methodology feasible and described in sufficient detail to allow the work to be replicable? Descriptions of methods and materials in the protocol should be reported in sufficient detail for another researcher to reproduce all experiments and analyses. The protocol should describe the appropriate controls, sample size calculations, and replication needed to ensure that the data are robust and reproducible. Reviewer #3: Yes ********** 4. Have the authors described where all data underlying the findings will be made available when the study is complete? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception, at the time of publication. The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #3: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #3: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above and, if applicable, provide comments about issues authors must address before this protocol can be accepted for publication. You may also include additional comments for the author, including concerns about research or publication ethics. You may also provide optional suggestions and comments to authors that they might find helpful in planning their study. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #3: The document is well written. There are a few data issues that should be clarified. For example, the quality control section appears to be directed to the researchers. The investigators state that the researcher will regularly monitor the trial. What exactly is ,'regularly'? Also in the pain assessment, the patient will rate their pain which can be somewhat subjective. How will this assessment be validated? This should at least be mentioned in the protocol. Concerning the sample size and analysis, the sample size appears adequate for a pilot effort. For comparative univariate statistical analysis, the t-test and Wilcoxon appear to suffice as needed. Are there any thoughts of any adjustment (multivariate perhaps) to the analysis based on relevant patient characteristics or clinical variables? Also , presumably statements such as ,” We will perform a predefined subgroup analysis of primary endpoints according to chest tube duration and the number of incisions.”, will be detailed in the protocol. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean? ). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy . Reviewer #3: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/ . PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org . Please note that Supporting Information files do not need this step. |
| Revision 3 |
|
<p>Electroacupuncture for acute postoperative pain during coughing after video-assisted thoracoscopic surgery : study protocol for a pilot randomized controlled trial PONE-D-24-42025R3 Dear Dr. Tu, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. If you have any questions relating to publication charges, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Hantong Hu Academic Editor PLOS ONE Additional Editor Comments (optional): All previous comments of 3 reviewers have been properly addressed by the authors and I have also participated in the peer review of this paper. I think this paper has reached the level for publication in the current form. Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Does the manuscript provide a valid rationale for the proposed study, with clearly identified and justified research questions? The research question outlined is expected to address a valid academic problem or topic and contribute to the base of knowledge in the field. Reviewer #3: Yes ********** 2. Is the protocol technically sound and planned in a manner that will lead to a meaningful outcome and allow testing the stated hypotheses? The manuscript should describe the methods in sufficient detail to prevent undisclosed flexibility in the experimental procedure or analysis pipeline, including sufficient outcome-neutral conditions (e.g. necessary controls, absence of floor or ceiling effects) to test the proposed hypotheses and a statistical power analysis where applicable. As there may be aspects of the methodology and analysis which can only be refined once the work is undertaken, authors should outline potential assumptions and explicitly describe what aspects of the proposed analyses, if any, are exploratory. Reviewer #3: Yes ********** 3. Is the methodology feasible and described in sufficient detail to allow the work to be replicable? Descriptions of methods and materials in the protocol should be reported in sufficient detail for another researcher to reproduce all experiments and analyses. The protocol should describe the appropriate controls, sample size calculations, and replication needed to ensure that the data are robust and reproducible. Reviewer #3: Yes ********** 4. Have the authors described where all data underlying the findings will be made available when the study is complete? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception, at the time of publication. The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #3: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #3: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above and, if applicable, provide comments about issues authors must address before this protocol can be accepted for publication. You may also include additional comments for the author, including concerns about research or publication ethics. You may also provide optional suggestions and comments to authors that they might find helpful in planning their study. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #3: It appears that all comments have been addressed and the appropriate additions to the paper have been included. I thank the investigators for the added clarification. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean? ). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy . Reviewer #3: No ********** |
| Formally Accepted |
|
PONE-D-24-42025R3 PLOS ONE Dear Dr. Tu, I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now being handed over to our production team. At this stage, our production department will prepare your paper for publication. This includes ensuring the following: * All references, tables, and figures are properly cited * All relevant supporting information is included in the manuscript submission, * There are no issues that prevent the paper from being properly typeset If revisions are needed, the production department will contact you directly to resolve them. If no revisions are needed, you will receive an email when the publication date has been set. At this time, we do not offer pre-publication proofs to authors during production of the accepted work. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few weeks to review your paper and let you know the next and final steps. Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. If we can help with anything else, please email us at customercare@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Hantong Hu Academic Editor PLOS ONE |