Peer Review History
| Original SubmissionJanuary 30, 2024 |
|---|
|
PONE-D-24-04161A portable lateral flow distance-based paper sensor for drinking water hardness testPLOS ONE Dear Dr. liu, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Apr 12 2024 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Elingarami Sauli, PhD Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. We note that the grant information you provided in the ‘Funding Information’ and ‘Financial Disclosure’ sections do not match. When you resubmit, please ensure that you provide the correct grant numbers for the awards you received for your study in the ‘Funding Information’ section. 3. Thank you for stating the following financial disclosure: "Natural Science Foundation of Shandong Province (ZR2021QH106, ZR2020QB153, ZR2022YQ123); the Taishan Scholars Program (tsqn201812088); the Education and Industry Integration Pilot Project of Qilu University of Technology (2023PY058, 2022PY036)" Please state what role the funders took in the study. If the funders had no role, please state: ""The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript."" If this statement is not correct you must amend it as needed. Please include this amended Role of Funder statement in your cover letter; we will change the online submission form on your behalf. 4. Thank you for stating the following in the Acknowledgments Section of your manuscript: "Acknowledgements This work was supported by the Natural Science Foundation of Shandong Province (ZR2021QH106, ZR2020QB153, ZR2022YQ123); the Taishan Scholars Program (tsqn201812088); the Education and Industry Integration Pilot Project of Qilu University of Technology (2023PY058, 2022PY036)." Please be informed that funding information should not appear in the Acknowledgments section or other areas of your manuscript. We will only publish funding information present in the Funding Statement section of the online submission form. Please remove any funding-related text from the manuscript and let us know how you would like to update your Funding Statement. Currently, your Funding Statement reads as follows: "Natural Science Foundation of Shandong Province (ZR2021QH106, ZR2020QB153, ZR2022YQ123); the Taishan Scholars Program (tsqn201812088); the Education and Industry Integration Pilot Project of Qilu University of Technology (2023PY058, 2022PY036)" Please include your amended statements within your cover letter; we will change the online submission form on your behalf. 5. PLOS requires an ORCID iD for the corresponding author in Editorial Manager on papers submitted after December 6th, 2016. Please ensure that you have an ORCID iD and that it is validated in Editorial Manager. To do this, go to ‘Update my Information’ (in the upper left-hand corner of the main menu), and click on the Fetch/Validate link next to the ORCID field. This will take you to the ORCID site and allow you to create a new iD or authenticate a pre-existing iD in Editorial Manager. Please see the following video for instructions on linking an ORCID iD to your Editorial Manager account: https://www.youtube.com/watch?v=_xcclfuvtxQ 6. Please include a copy of Table 1 which you refer to in your text on page 17 (in PDF format). 7. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information. 8. Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. Additional Editor Comments: When responding to reviewer comments please make sure to improve the abstract, introduction, and discussion parts, not forgetting to clearly indicate the innovation in your work. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Partly Reviewer #2: Yes Reviewer #3: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: N/A Reviewer #2: Yes Reviewer #3: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: No Reviewer #2: Yes Reviewer #3: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: This manuscript reported a portable lateral flow distance-based paper sensor for drinking water hardness test. However, the manuscript is not well-written. Here gives some suggestions for improvement of the manuscript: 1. The abstract section needs to be revised, more information should be mentioned, such as the recoveries of the tested purified water. 2. The third paragraph of Introduction needs to be revised. The paper-based lateral flow sensor and its applications should be introduced first, followed by the distance signal readout method and its applications, and finally the analyte-responsive hydrogels. 3. “Condition optimization of the paper sensor” section, the author declared that “Moreover, the similar variation tendency was found for the solution and the mixture of Alg and Ca2+, respectively.” The data should be provided. 4. The author declared that “The concentrations of Ca2+ were determined by the paper sensor, the water hardness kit and inductively coupled plasma-mass spectrometry (ICP-MS) (Fig.S5).” However, Fig.S5 is just a graph of the paper-based sensor in response to different added concentration of Ca2+. 5. Table 1 is missing. 6. In Fig. S2 captions, the concentrations of Ca2+ (0, 1, 2, 5 and 10 mM) is wrong. 7. The discussion of Fig.S4 in the main text is missing. Moreover, other metal ions in the water sample can also affect the sensor's results, not just chloride ions. Reviewer #2: In the present manuscript, the authors have made an interesting design of A portable lateral flow distance-based paper sensor for testing hardness of drinking water. The study is simple therefore, novelty should be highlighted. A thorough literature survey must be included. The characterizations especially for the paper based sensors should be improved. The study related to repeatability and stability must be presented. Paper can be accepted after these minor revision. Reviewer #3: The authors developed a simple and portable lateral flow sensor with distance reading signal for the semiquantitative detection of drinking water hardness. Where the Ca2+/Mg2+ concentration can be determined by the water lateral flow distance on paper strips of the upper aqueous solution. Several studies have been carried out, including 1) Optimization of sodium alginate concentration, 2) Determination of water hardness using commercial test kit, 3) Feasibility of Ca2+/Mg2+ detection of the paper sensor, 4) Condition optimization of the paper sensor, 5) Detection of Ca2+ and Mg2+, 6) The semi-quantitative detection of water hardness using the paper sensor and 7) Comparison of the paper sensor with commercial kit for Ca2+ determination. Sample analyze was also performed. The article shows important results for the area of knowledge. However, the manuscript presents few points that should be improved to final decision. Required comments: 1) Review the units. Preferably use mol L-1, g L-1, Temperature in K, etc. According to the international system of units. 2) Does study involving pH and temperature variation is necessary for the optimization of sodium alginate concentration? 3) Did the authors measure sensor stability? 4) If possible, include a table comparing the values obtained with literature data from other sensors. ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: Yes: Dr Khairunnisa Amreen Reviewer #3: Yes: Emerson Schwingel Ribeiro ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 1 |
|
PONE-D-24-04161R1A portable lateral flow distance-based paper sensor for drinking water hardness testPLOS ONE Dear Dr. liu, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. ============================== The authors should improve the introduction and discussion parts, including justification of the procedure used when compared with other similar methods. ============================== Please submit your revised manuscript by Jul 06 2024 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Elingarami Sauli, PhD Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: (No Response) Reviewer #3: All comments have been addressed Reviewer #4: (No Response) Reviewer #5: (No Response) ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #3: Yes Reviewer #4: Yes Reviewer #5: No ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #3: Yes Reviewer #4: (No Response) Reviewer #5: No ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #3: Yes Reviewer #4: (No Response) Reviewer #5: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #3: Yes Reviewer #4: (No Response) Reviewer #5: No ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: After the revisions, the paper improved significantly. The manuscript's structure, flow, or writing is acceptable for publication. Reviewer #3: The authors made the necessary corrections presented by the reviewers. The article is ready to be published in Plos One. Reviewer #4: This manuscript has been carefully revised according to the suggestions of first-round review. Followings are some suggestions for further revisions. 1, There are commercially available instrument for measuring the hardness of water, which like the pH meter. Please also introduce them in the introduction section, and include this type instrument for comparison in the measurement of hardness of water in the experimental section. 2, According to the Reviewer #1 of first-round review, there are several errors in the manuscript. Please double check the manuscript. 3, Do not use non-English terms such as "anti-interference" or "foreign ions". Make use of correct terms "Selectivity" and "potentially interfering ions", respectively. 4, Please avoid using first-person narratives for a scientific paper. 5, The shortcomings of present work can be emphasized in the conclusion section. 6, Please carefully check and unify the units. For example, both the “mM” and “mmol-1” have been used in the manuscript. Reviewer #5: The manuscript "A portable lateral flow distance-based paper sensor for drinking water hardness test" describes a paper-based device for the determination of water hardness, expressed as Ca2+ and Mg2+ concentration, based on the formation of a hydrogel after the chelation with sodium alginate. Although the idea of the study is interesting, I do not think the quality of the manuscript support its publication. To be considered, an improvment must be performed. Some specific comments: a) The English language throughout the manuscript must be revised. There are many typos (e.g. thrice) and strange sentences (e.g. Drinking water quality is a problem concerned by people). The peer-reviewing is not a proof reading service, so the English must be revised by someone dedicated to it. b) A broader literature revision must be done. There are, at least, two papers dealing with the determination of water hardness using paper-based devices that were not mentioned (10.1016/j.measurement.2020.108085 and 10.3390/su14063363). It should be inserted and discussed. c) Eriochrome T is the most usual "reagent" for the determination of water hardness. Why your procedure is better? d) "anti-interference" sounds strange e) The "Cr values" is not clear how to calculate. Please clarify it. f) The images were taken with no illumination control? Is the results affected by different illumination conditions? It should be discussed. g) Test-t should be performed to compare the results obtained by the proposed method with the reference ones. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #3: Yes: Emerson Schwingel Ribeiro Reviewer #4: No Reviewer #5: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 2 |
|
A portable lateral flow distance-based paper sensor for drinking water hardness test PONE-D-24-04161R2 Dear Dr. Yulin Liu We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. If you have any questions relating to publication charges, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Elingarami Sauli, PhD Academic Editor PLOS ONE Additional Editor Comments (optional): All reviewers' (original and secondary) comments have been addressed to my satisfaction. The submission can be accepted with minor editorial revisions as highlighted below. Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #5: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #5: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #5: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #5: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #5: No ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #5: The authors made susbtantial changes in the revised version of the manuscript. The results are now better presented and the introduction section has improved. Prior to the publication, some revisions are still needed. a) Some expressions and sentences still needs improvment, such as: the usage of the word "Remarkably" in the abstract is unecessary. The sentence "Upon the Alg solution was incubation..." and "S2 Fig" need revision. b) Only cations Na+ and K+ were evaluated as interferent. Why? More cations should be investigated. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #5: No ********** |
| Formally Accepted |
|
PONE-D-24-04161R2 PLOS ONE Dear Dr. Liu, I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now being handed over to our production team. At this stage, our production department will prepare your paper for publication. This includes ensuring the following: * All references, tables, and figures are properly cited * All relevant supporting information is included in the manuscript submission, * There are no issues that prevent the paper from being properly typeset If revisions are needed, the production department will contact you directly to resolve them. If no revisions are needed, you will receive an email when the publication date has been set. At this time, we do not offer pre-publication proofs to authors during production of the accepted work. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few weeks to review your paper and let you know the next and final steps. Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. If we can help with anything else, please email us at customercare@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Elingarami Sauli Academic Editor PLOS ONE |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .