Peer Review History
| Original SubmissionFebruary 8, 2024 |
|---|
|
PONE-D-24-03563Impact of non-invasive oxygen reserve index versus standard SpO2 monitoring on peripheral oxygen saturation during endotracheal intubation in the intensive care unit: Protocol for the randomized controlled trial NESOI2 PLOS ONE Dear Dr. Lascarrou, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Apr 20 2024 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Ryo Yamamoto Academic Editor PLOS ONE Journal requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. We note that the grant information you provided in the ‘Funding Information’ and ‘Financial Disclosure’ sections do not match. When you resubmit, please ensure that you provide the correct grant numbers for the awards you received for your study in the ‘Funding Information’ section. 3. Thank you for stating the following financial disclosure: “French Ministry of Health. PHRC 2021.” Please state what role the funders took in the study. If the funders had no role, please state: "The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript." If this statement is not correct you must amend it as needed. Please include this amended Role of Funder statement in your cover letter; we will change the online submission form on your behalf. 4. Thank you for stating the following in the Competing Interests section: “JBL has received lecturing fees from BD and Masimo. Alexis Ferré reports honoraria by Fisher & Paykel for a lecture during SFMU Congress 2022, outside the submitted work. All other authors reports not competing interests.” Please confirm that this does not alter your adherence to all PLOS ONE policies on sharing data and materials, by including the following statement: "This does not alter our adherence to PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests). If there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared. Please include your updated Competing Interests statement in your cover letter; we will change the online submission form on your behalf. 5. One of the noted authors is a group or consortium [CRICS-TRIGGERSEP Network]. In addition to naming the author group, please list the individual authors and affiliations within this group in the acknowledgments section of your manuscript. Please also indicate clearly a lead author for this group along with a contact email address. 6. We note that Figure 4 in your submission contain copyrighted images. All PLOS content is published under the Creative Commons Attribution License (CC BY 4.0), which means that the manuscript, images, and Supporting Information files will be freely available online, and any third party is permitted to access, download, copy, distribute, and use these materials in any way, even commercially, with proper attribution. For more information, see our copyright guidelines: http://journals.plos.org/plosone/s/licenses-and-copyright. We require you to either (1) present written permission from the copyright holder to publish these figures specifically under the CC BY 4.0 license, or (2) remove the figures from your submission: 1. You may seek permission from the original copyright holder of Figure 4 to publish the content specifically under the CC BY 4.0 license. We recommend that you contact the original copyright holder with the Content Permission Form (http://journals.plos.org/plosone/s/file?id=7c09/content-permission-form.pdf) and the following text: “I request permission for the open-access journal PLOS ONE to publish XXX under the Creative Commons Attribution License (CCAL) CC BY 4.0 (http://creativecommons.org/licenses/by/4.0/). Please be aware that this license allows unrestricted use and distribution, even commercially, by third parties. Please reply and provide explicit written permission to publish XXX under a CC BY license and complete the attached form.” Please upload the completed Content Permission Form or other proof of granted permissions as an "Other" file with your submission. In the figure caption of the copyrighted figure, please include the following text: “Reprinted from [ref] under a CC BY license, with permission from [name of publisher], original copyright [original copyright year].” 2. If you are unable to obtain permission from the original copyright holder to publish these figures under the CC BY 4.0 license or if the copyright holder’s requirements are incompatible with the CC BY 4.0 license, please either i) remove the figure or ii) supply a replacement figure that complies with the CC BY 4.0 license. Please check copyright information on all replacement figures and update the figure caption with source information. If applicable, please specify in the figure caption text when a figure is similar but not identical to the original image and is therefore for illustrative purposes only. 7. We note that the original protocol that you have uploaded as a Supporting Information file contains an institutional logo. As this logo is likely copyrighted, we ask that you please remove it from this file and upload an updated version upon resubmission. Additional Editor Comments: Thank you for submitting the protocol of interesting study. Please see reviewer's comment. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Does the manuscript provide a valid rationale for the proposed study, with clearly identified and justified research questions? The research question outlined is expected to address a valid academic problem or topic and contribute to the base of knowledge in the field. Reviewer #1: Yes Reviewer #2: Yes ********** 2. Is the protocol technically sound and planned in a manner that will lead to a meaningful outcome and allow testing the stated hypotheses? The manuscript should describe the methods in sufficient detail to prevent undisclosed flexibility in the experimental procedure or analysis pipeline, including sufficient outcome-neutral conditions (e.g. necessary controls, absence of floor or ceiling effects) to test the proposed hypotheses and a statistical power analysis where applicable. As there may be aspects of the methodology and analysis which can only be refined once the work is undertaken, authors should outline potential assumptions and explicitly describe what aspects of the proposed analyses, if any, are exploratory. Reviewer #1: Partly Reviewer #2: Yes ********** 3. Is the methodology feasible and described in sufficient detail to allow the work to be replicable? Descriptions of methods and materials in the protocol should be reported in sufficient detail for another researcher to reproduce all experiments and analyses. The protocol should describe the appropriate controls, sample size calculations, and replication needed to ensure that the data are robust and reproducible. Reviewer #1: Yes Reviewer #2: Yes ********** 4. Have the authors described where all data underlying the findings will be made available when the study is complete? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception, at the time of publication. The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above and, if applicable, provide comments about issues authors must address before this protocol can be accepted for publication. You may also include additional comments for the author, including concerns about research or publication ethics. You may also provide optional suggestions and comments to authors that they might find helpful in planning their study. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: Thank you for sharing the manuscript titled "Impact of Non-Invasive Oxygen Reserve Index Versus Standard SpO2 Monitoring on Peripheral Oxygen Saturation During Endotracheal Intubation in the Intensive Care Unit: Protocol for the Randomized Controlled Trial NESOI2" for review. The paper outlines a research protocol assessing the impact of preoxygenation guided by the Oxygen Reserve Index (ORI) on the severity of desaturation during orotracheal intubation in ICU settings. The manuscript is well-written and largely unambiguous. The methodology is thoroughly described and detailed. I have no significant comments. Abstract Line 85: "ORI target for preoxygenation of at least 0.6 for at least 1 minute." Please explain the rationale for selecting this specific target. Line 85: "Preoxygenation is guided by SpO2 values recorded by a standard pulse oximeter, according to the standard of care." Could you describe how SpO2 guides preoxygenation? (Is it aiming for a SpO2 of 100% for a specific duration?). Main Manuscript • Line 189: Please explain the relevance of reference 19 in the methodology. Does it describe a study with a similar methodology? Or is it related to another aspect? In any case, if the reference is cited to justify methodological choices (such as the rationale behind the decision to monitor saturation 2 minutes post-intubation), it would be more appropriate to include it in the discussion section. • Line 190: "The secondary outcome includes the sensitivity analysis of the primary outcome." This analysis pertains to alternative statistical presentations of the primary endpoint. I suggest relocating this alongside the calculations for the primary endpoint. • Line 257: "Chosen based on unpublished personal data (JBL)." Please provide a brief description of what these data have shown. • Line 264: "The intensivist will not be aware of the SpO2 and ORI values..." If the intensivist is unaware of these monitors, on what basis will he determine the duration of preoxygenation? • Line 291: "Intubating intensivist..." If the choice of drugs is left to the discretion of the intensivist, I see no value in citing recommendations. • Line 322: The various phases, durations, and definitions could be graphically represented on a timeline, enhancing understanding. • The choice of alternative devices for initial preoxygenation should be controlled. Suppose the distribution of alternatives to preoxygenation differs between groups. In that case, it might raise questions about whether the difference in preoxygenation quality is related to the monitoring or the preoxygenation tool. Reviewer #2: Impact of non-invasive oxygen reserve index versus standard SpO2 monitoring on peripheral oxygen saturation during endotracheal intubation in the intensive care unit: Protocol for the randomized controlled trial NESOI Thank you for considering me for this review. This is a protocol for a multicenter, two-arm, 83 parallel-group, randomized, superiority, open trial in 950 critically ill adults requiring endo tracheal intubation (ETI) aiming at monitoring ORI values and using an oxygen reserve index (ORI) target for 85 preoxygenation of at least 0.6 for at least 1 minute as compared to a standard of care SpO2 monitoring. The protocol is well written and could have significant implications on the care of this vulnerable patient group by potentially preventing desaturations. Here are my comments: • ICU patients needing intubation are a heterogenous population. I think including a respiratory failure patient or a congestive cardiac patient with a trauma or septic patient would skew the results. The study would benefit from a more homogenous study population. • Since ORI values represent a PaO2 of >100mmHg none of the patients with SpO2 <98%, will have a measurable ORI value. Therefore, I would suggest explicitly excluding patients who do not reach an SpO2 of 99-100% after 3-5 min of preoxygenation. • P 9, first paragraph – the primary outcome measurement time (lowest SpO2 value, first introduction of the laryngoscope into the mouth and the end of the second 189 minute following successful intubation) seems too short to me. Two minutes after intubation could be too short for SpO2 to recover after apnea in critically ill patients. • P 9, R 197 – As mentioned above, ORI will be 0 at SpO2 >98%, thus it can’t assess severe hypoxic events ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: Yes: Issam Tanoubi Reviewer #2: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.
|
| Revision 1 |
|
PONE-D-24-03563R1Impact of non-invasive oxygen reserve index versus standard SpO2 monitoring on peripheral oxygen saturation during endotracheal intubation in the intensive care unit: Protocol for the randomized controlled trial NESOI2PLOS ONE Dear Dr. Lascarrou, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Jul 13 2024 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Ryo Yamamoto Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Does the manuscript provide a valid rationale for the proposed study, with clearly identified and justified research questions? The research question outlined is expected to address a valid academic problem or topic and contribute to the base of knowledge in the field. Reviewer #1: Yes Reviewer #2: Yes ********** 2. Is the protocol technically sound and planned in a manner that will lead to a meaningful outcome and allow testing the stated hypotheses? The manuscript should describe the methods in sufficient detail to prevent undisclosed flexibility in the experimental procedure or analysis pipeline, including sufficient outcome-neutral conditions (e.g. necessary controls, absence of floor or ceiling effects) to test the proposed hypotheses and a statistical power analysis where applicable. As there may be aspects of the methodology and analysis which can only be refined once the work is undertaken, authors should outline potential assumptions and explicitly describe what aspects of the proposed analyses, if any, are exploratory. Reviewer #1: Yes Reviewer #2: Yes ********** 3. Is the methodology feasible and described in sufficient detail to allow the work to be replicable? Descriptions of methods and materials in the protocol should be reported in sufficient detail for another researcher to reproduce all experiments and analyses. The protocol should describe the appropriate controls, sample size calculations, and replication needed to ensure that the data are robust and reproducible. Reviewer #1: Yes Reviewer #2: Yes ********** 4. Have the authors described where all data underlying the findings will be made available when the study is complete? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception, at the time of publication. The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above and, if applicable, provide comments about issues authors must address before this protocol can be accepted for publication. You may also include additional comments for the author, including concerns about research or publication ethics. You may also provide optional suggestions and comments to authors that they might find helpful in planning their study. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: Thank you for your revisions and for addressing the initial comments on your manuscript. Upon further review, I have two additional suggestions that could strengthen your submission: Responses to comments 1, 5, and 9 from Reviewer #1 should be incorporated into the discussion section of the article to better justify and explain the methodological choices made. Concerning Reviewer #2’s Comments: I understand that the authors prefer not to exclude patients with SpO₂ below 98% at the end of preoxygenation due to their rarity. However, it is essential to clearly describe in the statistical section how their data will be analyzed should this issue arise. Reviewer #2: The responses to my initial review have been answered. I accept the author's comments and I agree with the publication ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: Yes: Issam Tanoubi Reviewer #2: Yes: Peter Szmuk, M.D. ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 2 |
|
PONE-D-24-03563R2Impact of non-invasive oxygen reserve index versus standard SpO2 monitoring on peripheral oxygen saturation during endotracheal intubation in the intensive care unit: Protocol for the randomized controlled trial NESOI2PLOS ONE Dear Dr. Lascarrou, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. An additional statistical reviewer suggest some minor revisions. Please respond to them. Please submit your revised manuscript by Aug 16 2024 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript: A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Ryo Yamamoto Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Does the manuscript provide a valid rationale for the proposed study, with clearly identified and justified research questions? The research question outlined is expected to address a valid academic problem or topic and contribute to the base of knowledge in the field. Reviewer #1: Yes Reviewer #3: Yes ********** 2. Is the protocol technically sound and planned in a manner that will lead to a meaningful outcome and allow testing the stated hypotheses? The manuscript should describe the methods in sufficient detail to prevent undisclosed flexibility in the experimental procedure or analysis pipeline, including sufficient outcome-neutral conditions (e.g. necessary controls, absence of floor or ceiling effects) to test the proposed hypotheses and a statistical power analysis where applicable. As there may be aspects of the methodology and analysis which can only be refined once the work is undertaken, authors should outline potential assumptions and explicitly describe what aspects of the proposed analyses, if any, are exploratory. Reviewer #1: Yes Reviewer #3: Yes ********** 3. Is the methodology feasible and described in sufficient detail to allow the work to be replicable? Descriptions of methods and materials in the protocol should be reported in sufficient detail for another researcher to reproduce all experiments and analyses. The protocol should describe the appropriate controls, sample size calculations, and replication needed to ensure that the data are robust and reproducible. Reviewer #1: Yes Reviewer #3: Yes ********** 4. Have the authors described where all data underlying the findings will be made available when the study is complete? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception, at the time of publication. The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #3: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #3: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above and, if applicable, provide comments about issues authors must address before this protocol can be accepted for publication. You may also include additional comments for the author, including concerns about research or publication ethics. You may also provide optional suggestions and comments to authors that they might find helpful in planning their study. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: I thank the authors for adequately addressing the reviewers' comments. I have no further comments to add. Reviewer #3: On the overall, the manuscript addresses previously raised questions. My additional comments are as follows: 1. A linear mixed model will be fitted, which is based on Gaussian assumptions of the random terms (random effects & errors). What would be the recourse, when the Gaussian assumptions fail (which can certainly happen)? 2. Cox regression will be employed, but necessary goodness of fit statistics and tests of the proportional hazards assumptions need to be mentioned. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: Yes: Issam Tanoubi Reviewer #3: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 3 |
|
Impact of non-invasive oxygen reserve index versus standard SpO2 monitoring on peripheral oxygen saturation during endotracheal intubation in the intensive care unit: Protocol for the randomized controlled trial NESOI2 PONE-D-24-03563R3 Dear Dr. Lascarrou, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. If you have any questions relating to publication charges, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Ryo Yamamoto Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Does the manuscript provide a valid rationale for the proposed study, with clearly identified and justified research questions? The research question outlined is expected to address a valid academic problem or topic and contribute to the base of knowledge in the field. Reviewer #3: Yes ********** 2. Is the protocol technically sound and planned in a manner that will lead to a meaningful outcome and allow testing the stated hypotheses? The manuscript should describe the methods in sufficient detail to prevent undisclosed flexibility in the experimental procedure or analysis pipeline, including sufficient outcome-neutral conditions (e.g. necessary controls, absence of floor or ceiling effects) to test the proposed hypotheses and a statistical power analysis where applicable. As there may be aspects of the methodology and analysis which can only be refined once the work is undertaken, authors should outline potential assumptions and explicitly describe what aspects of the proposed analyses, if any, are exploratory. Reviewer #3: Yes ********** 3. Is the methodology feasible and described in sufficient detail to allow the work to be replicable? Descriptions of methods and materials in the protocol should be reported in sufficient detail for another researcher to reproduce all experiments and analyses. The protocol should describe the appropriate controls, sample size calculations, and replication needed to ensure that the data are robust and reproducible. Reviewer #3: Yes ********** 4. Have the authors described where all data underlying the findings will be made available when the study is complete? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception, at the time of publication. The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #3: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #3: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above and, if applicable, provide comments about issues authors must address before this protocol can be accepted for publication. You may also include additional comments for the author, including concerns about research or publication ethics. You may also provide optional suggestions and comments to authors that they might find helpful in planning their study. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #3: The authors were able to address my previous round of questions. I have no further questions this round. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #3: No ********** |
| Formally Accepted |
|
PONE-D-24-03563R3 PLOS ONE Dear Dr. Lascarrou, I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now being handed over to our production team. At this stage, our production department will prepare your paper for publication. This includes ensuring the following: * All references, tables, and figures are properly cited * All relevant supporting information is included in the manuscript submission, * There are no issues that prevent the paper from being properly typeset If revisions are needed, the production department will contact you directly to resolve them. If no revisions are needed, you will receive an email when the publication date has been set. At this time, we do not offer pre-publication proofs to authors during production of the accepted work. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few weeks to review your paper and let you know the next and final steps. Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. If we can help with anything else, please email us at customercare@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Ryo Yamamoto Academic Editor PLOS ONE |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .