Peer Review History

Original SubmissionJanuary 17, 2024
Decision Letter - Abel C.H. Chen, Editor

PONE-D-24-02202Show-through removal with sparsity-based blind deconvolutionPLOS ONE

Dear Dr. Kawakami,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

Please submit your revised manuscript by Apr 01 2024 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Abel C.H. Chen

Academic Editor

PLOS ONE

Journal requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. Please note that PLOS ONE has specific guidelines on code sharing for submissions in which author-generated code underpins the findings in the manuscript. In these cases, all author-generated code must be made available without restrictions upon publication of the work. Please review our guidelines at https://journals.plos.org/plosone/s/materials-and-software-sharing#loc-sharing-code and ensure that your code is shared in a way that follows best practice and facilitates reproducibility and reuse.

3. When completing the data availability statement of the submission form, you indicated that you will make your data available on acceptance. We strongly recommend all authors decide on a data sharing plan before acceptance, as the process can be lengthy and hold up publication timelines. Please note that, though access restrictions are acceptable now, your entire data will need to be made freely accessible if your manuscript is accepted for publication. This policy applies to all data except where public deposition would breach compliance with the protocol approved by your research ethics board. If you are unable to adhere to our open data policy, please kindly revise your statement to explain your reasoning and we will seek the editor's input on an exemption. Please be assured that, once you have provided your new statement, the assessment of your exemption will not hold up the peer review process.

4. Please include a separate caption for each figure in your manuscript.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Yes

Reviewer #2: Partly

**********

2. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

Reviewer #2: I Don't Know

**********

3. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: Yes

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

**********

5. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: In this paper, the blind image deconvolution problem, which is the original image and the point spread function (PSF) are unknown, has been studied. This type of problem cannot be directly solved due to ill-conditioned, and therefore minimization methods are used for this type of problem. The subject under study is a practical one that holds interest for researchers in the field of image processing. While the paper is well-written both scientifically and in terms of its text, it needs to be improved. Some of the corrections that need to be made are listed below.

1- The time required for the algorithm should be examined through an example.

2- To enhance interpretability, the authors should specify the type of system employed for simulating the algorithm. Details such as the simulation environment (Matlab, C, Python, etc.), hardware (CPU or GPU), operating system (Windows or Linux), and other relevant information should be included in the text.

3- The discussion of the convergence of the presented method may be lengthy and challenging in terms of theory. However, it is recommended that the authors demonstrate the convergence of the method in the numerical results section by plotting the changes in PSNR and SSIM values against the number of iterations.

4- In order to be able to simulate the algorithm, the source of the images used in the paper must be stated.

5- The selection of the regularization parameters (\\alpha and \\beta) in the total variation problems are a challenging issue and various methods have been introduced to select these parameters. In the current paper, these parameters have been selected as a fixed number. However, different results are obtained by changing these parameters. The authors are advised to calculate the PSNR and SSIM values in a table for different values of these parameters.

Reviewer #2: Why you didn't use autoencoder as anomaly detection? Autoencoders is a good self-supervised machine learning technique which can use as anomaly detection (Autoencoders and their Applications inMachine Learning: A Survey, DOI: 10.1007/s10462-023-10662-6).

**********

6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: No

**********

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

Revision 1

Thanks to all the reviewers.

Thank you for your comments and helpful suggestions to improve our paper. We have incorporated all your suggestions into the revised version as explained below.

Response to the reviewer #1

Consern#1: The time required for the algorithm should be examined through an example.

We added the computation times of our simulation experiments in Tables 6 and 7 (Page 17 and 18). Furthermore, Section 5.1.6 was added to explain Tables 6 and 7 (Page 17). From Table 6, it is observed that the optimization method using APG + SVP described in Section 4.2.2 significantly reduces the computation time compared with the PG + SVP. From Table 7, it is observed that the proposed method needs a longer computation time than the other comparison methods. This drawback needs to be overcome in future work, for example by using parallel processing.

Consern#2: To enhance interpretability, the authors should specify the type of system employed for simulating the algorithm. Details such as the simulation environment (Matlab, C, Python, etc.), hardware (CPU or GPU), operating system (Windows or Linux), and other relevant information should be included in the text.

We added Table 1 which summarizes the hardware and software environment used in the experimental studies in Section 5.1 (Page 11). Furthermore, one sentence was added to explain Table 1 (Page 11).

Consern#3: The discussion of the convergence of the presented method may be lengthy and challenging in terms of theory. However, it is recommended that the authors demonstrate the convergence of the method in the numerical results section by plotting the changes in PSNR and SSIM values against the number of iterations.

We performed new experiments (experiments 5 and 6) in Section 5.1.3 to evaluate the convergence of the proposed method with the recommended APG + SVP optimization method. We added Fig 8 which shows graphs of the changes of PSNR and SSIM indices according to the iteration number (Page 14). Furthermore, Section 5.1.3 was added to explain Fig 8 (Page 14). From Fig 8, it is observed that both PSNR and SSIM converges at 200 iterations and the convergence is stable with no divergence or oscillating behavior. From this experiment, we think that it can be said that the convergence of the method is guaranteed and 200 iterations are sufficient for the convergence.

In addition, in the experiments of the optimization methods in Section 5.1.4, we added Fig 9, which shows graphs of the changes of PSNR index for each optimization method (Page 15). Furthermore, a sentence was added to explain Fig 9 (Page 15). It is observed that the recommended APG + SVP method converged fastest among all the four investigated optimization methods.

Consern#4: In order to be able to simulate the algorithm, the source of the images used in the paper must be stated.

All images used in the simulation studies were artificially generated by ourselves. We added a sentence to state this fact in Section 5.1 (Page 11). All images used in the real image experiments were acquired by ourselves by scanning real papers having printed materials on the both sides using an electronic scanner. We added a sentence to state this fact in Section 5.2 (Page 18).

For other researchers, all the image files we used in the experiments are attached to S1 (images used in the simulation experiments) and S2 (images used in the real image experiments) in Supporting Information Section (Page 20).

Consern#5: The selection of the regularization parameters (\\alpha and \\beta) in the total variation problems are a challenging issue and various methods have been introduced to select these parameters. In the current paper, these parameters have been selected as a fixed number. However, different results are obtained by changing these parameters. The authors are advised to calculate the PSNR and SSIM values in a table for different values of these parameters.

The proposed method involves two regularization parameters (i.e. α and β). We added Section 5.1.2 (Page 13), which explains the effect of α and β on quality of the restored image. This section includes results of newly performed experiments (Figs 5, 6, 7 and Table 3) (Page 13 and 14), which demonstrate the effect of β on the image quality. We believe that this answers to your comments in a good way. We repeat the added Section 5.1.2 in the next paragraph for your convenience.

The proposed method involves two regularization parameters (i.e. α and β). This section demonstrates the effect of α and β on quality of the restored image. The first parameter α in Eq (16) is the parameter to evaluate the magnitude of the nuclear norm. However, the proposed method with the recommended AGP + SVP optimization method does not need to adjust α. This is because it uses the singular value projection (SVP) instead of the nuclear norm reduction, which directly imposes the constraint that the rank of X is one by computing only one largest singular value and discarding other singular values. The second parameter β affects quality of the restored image. To evaluate the effect of β on the image quality, the same simulation experiments as in Experiment 1 and Experiment 2 were performed with five different values of β (i.e. β=0.0,1.0,2.5,5.0,10.0). These experiments are named as Experiment 3 and Experiment 4, respectively. Figs 5 and 6 show zoomed small parts of the restored images for each value of β. Table 3 summarizes PSNR and SSIM indices for each value of β. Fig 7 shows changes of PSNR and SSIM indices with different β values. It is observed that increasing β value has no significant effect on large edge parts such as those in Figs 5(a), (b) and 6(a), but it does smooth out fine edges such as those in Fig 6(b). From Fig 7 and Table 3, it is also observed that if β is made too large, PSNR and SSIM indices become worse and β=2.5 yields the best restoration accuracy in average for the setup of Experiments 3 and 4. Finally, we mention that the image quality was not very sensitive to β value than what we expected before these experiments.

Response to the reviewer #2: Why you didn't use autoencoder as anomaly detection? Autoencoders is a good self-supervised machine learning technique which can use as anomaly detection (Autoencoders and their Applications inMachine Learning: A Survey, DOI: 10.1007/s10462-023-10662-6).

After reading your comments, we performed a literature survey. Consequently, we found several show-through removal methods using Auto-encoder. For example, these include a supervised method (DOI:10.1016/j.patcog.2018.08.011), a self-supervised method (DOI:10.48550/arXiv.2203.04814), and an unsupervised method (DOI:10.1016/j.patcog.2021.108099). All of them are based on binarization. We added the most famous method (DOI:10.1016/j.patcog.2018.08.011) as a reference [14] in Introduction (Page 3). Furthermore, in Introduction, we added our short comment repeated in the next paragraphs on the comparison between the optimization-based approach and the Auto-encoder-based approach (Page 3).

Also, in recent years, a show-through removal method using Convolutional Neural Network (CNN) [13] has also been proposed. Among them, the method based on image binarization using Auto-encoder [14] is promising. The Auto-encoder-based approach like [14] can certainly perform accurate show-through removal with only one-sided input image. However, it has the following drawbacks. Since the method uses the image binarization, images with gradations or shadings cannot be recovered well. Furthermore, their accuracy depends on used training data. On the other hand, our proposed method requires both of an image of the fore side and that of the back side, but can be applied to images with gradations or shadings. At the current stage, we believe that both the optimization-based approach like ours and the Auto-encoder-based approach are meaningful to study, because they have different advantages and disadvantages and the both may be able to be combined in the future to develop more accurate or more convenient methods.

Attachments
Attachment
Submitted filename: Response_to_the_reviewers_revision1.docx
Decision Letter - Abel C.H. Chen, Editor

PONE-D-24-02202R1Show-through removal with sparsity-based blind deconvolutionPLOS ONE

Dear Dr. Kawakami,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

Please submit your revised manuscript by Jun 22 2024 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Abel C.H. Chen

Academic Editor

PLOS ONE

Journal Requirements:

Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation.

Reviewer #1: All comments have been addressed

Reviewer #2: All comments have been addressed

**********

2. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Yes

Reviewer #2: Yes

**********

3. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

Reviewer #2: Yes

**********

4. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: No

**********

5. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

**********

6. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: After reviewing the original text, the revised versions, and the opinions of the referees, as well as considering the answers provided and evaluating the article from a scientific standpoint, I believe that the manuscript in its current form may be considered for the next phase of the editorial process.

Also, as a recommendation for authors, it is suggested that the images and codes used for this article be placed on public repositories like GitHub and its address is mentioned in the text of the article. Additionally, the open-sourcing of the code not only facilitates the dissemination of the paper but also boosts its citation count.

Reviewer #2: All previously provided feedback has been duly addressed. However, it's recommended to consider referencing the most recent work on autoencoders, such as "Autoencoders and their applications in machine learning: a survey (2024)," instead of "A selectional auto-encoder approach for document image binarization (2019)," to ensure the inclusion of up-to-date and comprehensive literature in the manuscript.

**********

7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: No

**********

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

Revision 2

Thanks to all the reviewers.

Thank you for your second comments and helpful suggestions to improve our paper. We have incorporated all your suggestions into the revised version as explained below.

Reviewer #1: After reviewing the original text, the revised versions, and the opinions of the referees, as well as considering the answers provided and evaluating the article from a scientific standpoint, I believe that the manuscript in its current form may be considered for the next phase of the editorial process. Also, as a recommendation for authors, it is suggested that the images and codes used for this article be placed on public repositories like GitHub and its address is mentioned in the text of the article. Additionally, the open-sourcing of the code not only facilitates the dissemination of the paper but also boosts its citation count.

Thank you for your comment. According to your advice, I have added the link to repository to get images and codes used in the experiment in section 5.1 (Page 12).

Reviewer #2: All previously provided feedback has been duly addressed. However, it's recommended to consider referencing the most recent work on autoencoders, such as "Autoencoders and their applications in machine learning: a survey (2024)," instead of "A selectional auto-encoder approach for document image binarization (2019)," to ensure the inclusion of up-to-date and comprehensive literature in the manuscript.

Thank you for your comment. As you pointed, our reference to the approach using Auto-encoder was not good in the following sense. We cited a paper on the binarization of document image using Auto-encoder, but this is not a standard usage of Auto-encoder. Since a major application of Auto-encoder is to remove disturbance from images, which has been already proposed in image denoising, speckle reduction in SAR or ultrasound images, and clutter rejection in radar images. The same method can be also used to remove show-through from scanned images. Since the proposed optimization-based method and the Auto-encoder method have different advantages and disadvantages, it would be interesting to compare the two methods in terms of various points of views. So, according to your suggestion, we have made the following changes in the 2-nd revised version. First, we changed the cited paper (Ref. 14) from the previous one to the following new one, which you have introduced to us.

� Berahmand, K., Daneshfar, F., Salehi, E.S. et al. Autoencoders and their applications in machine learning: a survey. Artif Intell Rev 57, 28 (2024). https://doi.org/10.1007/s10462-023-10662-6

Second, we have changed the explanation on the use of Auto-encoder (on Page 3) as summarized in the next paragraph.

Also, in recent years, show-through removal methods using Convolutional Neural Network (CNN) have been proposed [13,14]. Among them, the method based on Auto-encoder [14] has a large potential. A typical major application of Auto-encoder is to remove disturbance from signals or images, which has been already proposed in image denoising, speckle reduction in SAR or ultrasound images, and clutter rejection in radar images. The same method can be also used to remove show-through from scanned images. This method requires only a single image of front side. However, its accuracy depends on used training data, and it may be weaker to the show-through having strong correlation with the front page image. On the other hand, our proposed method requires both of an image of the fore side and that of the back side, but using the two images eliminates the necessity of training data and may lead to an improved accuracy (for example, in the above mentioned case). At the current stage, we believe that both the optimization-based approach like ours and the Auto-encoder-based approach are meaningful to study, because they have different advantages and disadvantages and the both may be able to be combined in the future to develop more accurate or more convenient methods.

Attachments
Attachment
Submitted filename: Response_to_the_reviewers_revision2.docx
Decision Letter - Abel C.H. Chen, Editor

Show-through removal with sparsity-based blind deconvolution

PONE-D-24-02202R2

Dear Dr. Kawakami,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. If you have any questions relating to publication charges, please contact our Author Billing department directly at authorbilling@plos.org.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Abel C.H. Chen

Academic Editor

PLOS ONE

Additional Editor Comments (optional):

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation.

Reviewer #1: All comments have been addressed

Reviewer #2: (No Response)

**********

2. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Yes

Reviewer #2: (No Response)

**********

3. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

Reviewer #2: (No Response)

**********

4. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: (No Response)

**********

5. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: (No Response)

**********

6. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: The authors have addressed all the recommendations of the reviewers in a reasonable manner, the manuscript in the current form may be considered for the further phase of the editorial process.

Reviewer #2: The new version of the manuscript correctly do the previous comment.

All the previous comments have been investigated.

**********

7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: Yes: fatemeh daneshfar

**********

Formally Accepted
Acceptance Letter - Abel C.H. Chen, Editor

PONE-D-24-02202R2

PLOS ONE

Dear Dr. Kawakami,

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now being handed over to our production team.

At this stage, our production department will prepare your paper for publication. This includes ensuring the following:

* All references, tables, and figures are properly cited

* All relevant supporting information is included in the manuscript submission,

* There are no issues that prevent the paper from being properly typeset

If revisions are needed, the production department will contact you directly to resolve them. If no revisions are needed, you will receive an email when the publication date has been set. At this time, we do not offer pre-publication proofs to authors during production of the accepted work. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few weeks to review your paper and let you know the next and final steps.

Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

If we can help with anything else, please email us at customercare@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff

on behalf of

Dr. Abel C.H. Chen

Academic Editor

PLOS ONE

Open letter on the publication of peer review reports

PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.

We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.

Learn more at ASAPbio .