Peer Review History

Original SubmissionDecember 21, 2023
Decision Letter - Pierpaolo Alongi, Editor

PONE-D-23-43099Clinical and economic outcomes of adding 18F-FES PET/CT in estrogen receptor status identification in metastatic and recurrent breast cancer in the USPLOS ONE

Dear Dr. Munter-Young,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

Please submit your revised manuscript by Mar 11 2024 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Pierpaolo Alongi

Academic Editor

PLOS ONE

Journal Requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at 

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. Thank you for stating the following in the Competing Interests section: 

"I have read the journal's policy and the authors of this manuscript have the following competing interests: RM-Y, AF-A, and ND are employees of GE HealthCare, which funded the health economic analysis. KN and DG are employees of Certara Germany GmbH, a consulting company that was paid by GE HealthCare for the services rendered."

We note that one or more of the authors are employed by a commercial company: GE HealthCare, Certara Germany GmbH

(1) Please provide an amended Funding Statement declaring this commercial affiliation, as well as a statement regarding the Role of Funders in your study. If the funding organization did not play a role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript and only provided financial support in the form of authors' salaries and/or research materials, please review your statements relating to the author contributions, and ensure you have specifically and accurately indicated the role(s) that these authors had in your study. You can update author roles in the Author Contributions section of the online submission form.

Please also include the following statement within your amended Funding Statement. 

“The funder provided support in the form of salaries for authors [insert relevant initials], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.”

If your commercial affiliation did play a role in your study, please state and explain this role within your updated Funding Statement. 

(2) Please also provide an updated Competing Interests Statement declaring this commercial affiliation along with any other relevant declarations relating to employment, consultancy, patents, products in development, or marketed products, etc.  

Within your Competing Interests Statement, please confirm that this commercial affiliation does not alter your adherence to all PLOS ONE policies on sharing data and materials by including the following statement: ""This does not alter our adherence to  PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests) . If this adherence statement is not accurate and  there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared.

Please include both an updated Funding Statement and Competing Interests Statement in your cover letter. We will change the online submission form on your behalf.

3. PLOS requires an ORCID iD for the corresponding author in Editorial Manager on papers submitted after December 6th, 2016. Please ensure that you have an ORCID iD and that it is validated in Editorial Manager. To do this, go to ‘Update my Information’ (in the upper left-hand corner of the main menu), and click on the Fetch/Validate link next to the ORCID field. This will take you to the ORCID site and allow you to create a new iD or authenticate a pre-existing iD in Editorial Manager. Please see the following video for instructions on linking an ORCID iD to your Editorial Manager account: https://www.youtube.com/watch?v=_xcclfuvtxQ

4. Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Partly

Reviewer #2: Yes

**********

2. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

Reviewer #2: Yes

**********

3. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: Yes

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

**********

5. Review Comments to the Author

Reviewer #1: This manuscript endeavors to assess the financial implications and cost-effectiveness associated with the incorporation of the diagnostic technique [18F]FES PET/CT alongside biopsy/IHC in determining ER-positive status among patients with metastatic or recurrent breast cancer in the United States. The global significance of this paper lies in its clear demonstration of the synergistic role played by [18F]FES PET/CT and biopsy. It is desirable to adhere to the EANM nomenclature when referring to all radiotracers. In the Results section, tables require more detailed explanations within the text (e.g. Table 2 reports... etc.). Furthermore, the Discussion section should concentrate more on speculating about the role of [18F]FES PET/CT.

Reviewer #2: The manuscript is well-designed and provide important information regarding the cost saving of adding FES PET in the management of patients with breast cancer.

My comments are presented below:

- The methods needs an additional section or paragraph to describe how FES PET/CT has been carried out and how biopsy matched the PET/CT imaging.

- I suggest to add the mean expression of ER in true positive and false negative cases;

- I suggest to add the point that the procedure improves also the QOL (quality of life) of patients;

- The author may hypothise the economic impact in another economic scenario (e.g. Europe), where patients have no private medical insurance.

**********

6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: Yes: Natale Quartuccio

**********

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

Revision 1

Reviewers' Comments to the Authors:

Reviewer 1

This manuscript endeavors to assess the financial implications and cost-effectiveness associated with the incorporation of the diagnostic technique [18F]FES PET/CT alongside biopsy/IHC in determining ER-positive status among patients with metastatic or recurrent breast cancer in the United States. The global significance of this paper lies in its clear demonstration of the synergistic role played by [18F]FES PET/CT and biopsy.

Author response: Thank you!

1. Comment from Reviewer 1 on the need to adhere to the EANM nomenclature when referring to all radiotracers.

Author response: Thank you for highlighting this. The manuscript has been reviewed by all authors to confirm that the correct EANM nomenclature has been included. Reviewer 1 is correct, and we have adapted the naming of the radiotracers to the EANM nomenclature. More specifically, the first reference to FDG was changed to “2-deoxy-2-[18F]fluoro-D-glucose or 2-[18F]fluoro-2-deoxy-D-glucose” and each subsequent mention was cited as “[18F]FDG”. In addition, the first reference of FES was changed to “16α-[18F]fluoro-17β-fluoroestradiol” and “[18F]FES” for each successive reference. Finally “89Zr-trastuzumab” was changed to “[89Zr]Zr-Trastuzumab”

2. Comment from Reviewer 1 that tables in the Results section require more detailed explanations within the text.

Author response: As suggested, further explanations were added for all the tables and figures in the Results section. The revised text can be found on rows 209, 268 and 295.

[row 209] “Table 2 quantifies the economic, diagnostic, and clinical benefits of adding [18F]FES PET/CT to the diagnostic workup in mBC patients when a biopsy failed, was inconclusive, or not possible. Table 2 also quantifies the extent to which [18F]FES PET/CT in combination with IHC benefits rBC patients upon initial and over time.”

[row 268] “Introducing [18F]FES PET/CT to determine ER-positive status in mBC and rBC is cost effective as portrayed in Table 3.”

[row 295] “S2 shows the OWSA for the 10 most sensitive parameters in different subpopulations. Figure A identifies the parameters that impacts the ICER most among mBC patients when biopsy failed or was inconclusive. Similarly, Figure B illustrates the parameters that impact the ICER among mBC patients when biopsy was not possible, and Figure C shows them among rBC patients when [18F]FES PET/CT is used in combination with IHC.”

3. Comment from Reviewer 1 indicated that the Discussion section should speculate more about the role of [18F]FES PET/CT.

Author response: Thank you for the opportunity to expound on the benefits of FES. An entire section, beginning on row 386, has been added to the Discussion section highlighting additional benefits of integrating [18F]FES PET/CT into the diagnostic workup of mBC and rBC patients beyond those initially identified. In exploring these additional benefits, limitations associated with local radiotracer preparation, transportation and affordability were also included.

Reviewer 2

The manuscript is well-designed and provide important information regarding the cost saving of adding FES PET in the management of patients with breast cancer.

Author response: Thank you for the positive feedback.

1. Comment from Reviewer 2 to add a section or paragraph to the Methods section to describe how FES PET/CT has been carried out.

Author response: This important element was, in fact, omitted from the initially submitted manuscript and has been corrected in the updated version. The production of FES and a description of the administration of FES and PET/CT scan are outlined beginning on line 144 of the updated manuscript.

[row 144] “[18F]FES was produced locally as described by Roemer J, et al. and Venema CM et al. [49, 50] The [18F]FES PET/CT scans were performed on a BioGraph mCT 40- or 64-slice PET/CT (Siemens/CTI, Knoxville, TN) or an Ingenuity TF or Gemini TF PET/CT (Philips Medical Systems, Cleveland, OH) where about 200 MBq [18F]FES were injected intravenously as a bolus. As described by van Geel et al., PET/CT images were acquired 60 ± 10 minutes after tracer injection. Before the PET scan, a low-dose CT was conducted for attenuation and scatter correction. A whole-body PET emission scan was obtained with a 3-minute per bed position acquisition time. All patients were scanned from head to mid-thigh and for all scan reconstructions and quantifications, the European Association of Nuclear Medicine Research Limited (EARL) criteria were followed. A full account of [18F]FES PET/CT whole body evaluation and the quantity of FES taken up by the metastases is further described in by van Geel et al.”

2. Comment from Reviewer 2 to update the Methods section to describe how biopsy matched the PET/CT imaging.

Author response: An addition to the Methods section beginning on row 167 of the update manuscript explains the meta-analyses used to compare the diagnostic accuracy of biopsy/IHC and [18F]FES PET/CT

3. Comment from Reviewer 2 to add the mean expression of ER in true positive and false negative cases.

Author response: This was an oversight in the original manuscript, for which, again we thank the reviewer for this important feedback. A description of how the biopsy/IHC ER status matched those of the [18F]FES PET/CT were updated in Table 1, where the rates of true ER positive and ER negative were reported when an ER expression threshold of >1% was applied.

4. Comment from Reviewer 2 suggesting an addition about how the procedure improves patients’ QOL.

Author response: The quantifiable increase in patients’ QoL is very small and as such only a small change was made to the manuscript to reflect this on row 350.

“This study therefore suggests that adding [18F]FES PET/CT to biopsy/IHC could have a positive impact on clinical and economic outcomes as well as on patients´ quality of life (QoL) in the US.”

5. Comment from Reviewer 2 to hypnotize on the economic impact that FES may have in other economic scenarios (e.g., Europe), where patients have no private medical insurance.

Author response: Differences in local regulations that govern the production of radioactive diagnostics (outlined beginning on row 403), the cost to manufacture and distribute them may impact their acquisition price and subsequently the actual economic benefits; however, based on the results of the OWSA since the cost of the tracer has such a minimal impact on the cost-effectiveness, the cost-effectiveness of [18F]FES PET/CT as calculated in the US can be readily transferred to other payer archetypes.

“While there are limitations to increased use of molecular imaging in BC, these limitations are associated more with local regulations and realities linked to radiotracer preparation and transportation than access and affordability associated with different healthcare systems. Across different countries there are varying requirements that govern the production of molecular imaging agents. These rules dictate everything from the technology transfer to allow a third party to radiate a dose to the transport of radioactive materials thereby challenging their supply. Another limitation is the availability of PET machines on which to use the tracers. While this study has focused on the cost-effectiveness of [18F]FES PET/CT in the US, the outcomes should be transferable to other single Payer systems since the cost of the tracer has such a minimal impact on the (positive) outcomes (as evidence by the OWSA).”

Decision Letter - Pierpaolo Alongi, Editor

Clinical and economic outcomes of adding [18F]FES PET/CT in estrogen receptor status identification in metastatic and recurrent breast cancer in the US

PONE-D-23-43099R1

Dear Dr. Munter-Young,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. If you have any questions relating to publication charges, please contact our Author Billing department directly at authorbilling@plos.org.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Pierpaolo Alongi

Academic Editor

PLOS ONE

Additional Editor Comments (optional):

Reviewers' comments:

Formally Accepted
Acceptance Letter - Pierpaolo Alongi, Editor

PONE-D-23-43099R1

PLOS ONE

Dear Dr. Munter-Young,

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now being handed over to our production team.

At this stage, our production department will prepare your paper for publication. This includes ensuring the following:

* All references, tables, and figures are properly cited

* All relevant supporting information is included in the manuscript submission,

* There are no issues that prevent the paper from being properly typeset

If revisions are needed, the production department will contact you directly to resolve them. If no revisions are needed, you will receive an email when the publication date has been set. At this time, we do not offer pre-publication proofs to authors during production of the accepted work. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few weeks to review your paper and let you know the next and final steps.

Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

If we can help with anything else, please email us at customercare@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff

on behalf of

Dr. Pierpaolo Alongi

Academic Editor

PLOS ONE

Open letter on the publication of peer review reports

PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.

We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.

Learn more at ASAPbio .