Peer Review History
| Original SubmissionNovember 5, 2023 |
|---|
|
PONE-D-23-36475Accelerated corrosion of low carbon steel by oscillatory acidic streams generated with a bio-inspired claw devicePLOS ONE Dear Dr. Montoya, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. ACADEMIC EDITOR: Please, the Reviewers have suggested to a REVISION. Although, it seems that the manuscript deserves its publication, before a rebuttal letter detailing/commenting all suggestions should be provided. Please submit your revised manuscript by Jan 05 2024 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Wislei Riuper Osório Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. Please note that PLOS ONE has specific guidelines on code sharing for submissions in which author-generated code underpins the findings in the manuscript. In these cases, all author-generated code must be made available without restrictions upon publication of the work. Please review our guidelines at https://journals.plos.org/plosone/s/materials-and-software-sharing#loc-sharing-code and ensure that your code is shared in a way that follows best practice and facilitates reproducibility and reuse. 3. Please expand the acronym “UNAM-DGAPA” (as indicated in your financial disclosure) so that it states the name of your funders in full. This information should be included in your cover letter; we will change the online submission form on your behalf. 4. Thank you for stating the following financial disclosure: "UNAM-DGAPA-PAPIIT IG100623 program has financed this work. MMR thanks UNAM-DGAPA for the postdoctoral fellowship throughout the program POSDOC." Please state what role the funders took in the study. If the funders had no role, please state: "The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript." If this statement is not correct you must amend it as needed. Please include this amended Role of Funder statement in your cover letter; we will change the online submission form on your behalf. 5. Thank you for stating the following in the Acknowledgments Section of your manuscript: "UNAM-DGAPA-PAPIIT IG100623 program has financed this work. Montoya-Rangel thanks UNAM-DGAPA for the postdoctoral fellowship throughout the program POSDOC" We note that you have provided funding information that is not currently declared in your Funding Statement. However, funding information should not appear in the Acknowledgments section or other areas of your manuscript. We will only publish funding information present in the Funding Statement section of the online submission form. Please remove any funding-related text from the manuscript and let us know how you would like to update your Funding Statement. Currently, your Funding Statement reads as follows: "UNAM-DGAPA-PAPIIT IG100623 program has financed this work. MMR thanks UNAM-DGAPA for the postdoctoral fellowship throughout the program POSDOC." Please include your amended statements within your cover letter; we will change the online submission form on your behalf. 6. We note that you have stated that you will provide repository information for your data at acceptance. Should your manuscript be accepted for publication, we will hold it until you provide the relevant accession numbers or DOIs necessary to access your data. If you wish to make changes to your Data Availability statement, please describe these changes in your cover letter and we will update your Data Availability statement to reflect the information you provide. 7. Please upload a copy of Supporting Information Figure/Table/etc. Supporting Information S1 Appendix and S2 Appendix which you refer to in your text on page 12. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Partly Reviewer #3: Yes Reviewer #4: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: N/A Reviewer #2: No Reviewer #3: Yes Reviewer #4: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: No Reviewer #3: No Reviewer #4: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes Reviewer #4: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: Dear authors, the manuscript is overall well written and the results are well discussed. However, I have some questions and suggestions before it is published in PLOS ONE. Below I present my points: - The manuscript is appropriate for the subject matter. However, some sections could be simplified for better readability without sacrificing technical accuracy. Consider rephrasing complex sentences for clarity, particularly in the methodology section. A thorough proofreading for punctuation (such as comma usage) and sentence structure is recommended to enhance readability. - The use of a webcam and lamp for visualization is mentioned, but additional information on the exact setup, calibration, and limitations of this approach would strengthen this section. - In the results section, you've presented corrosion rates obtained through different methods (Rp analysis and Tafel extrapolation). How do these rates compare with those observed in real-world conditions, and what might be the reasons for any discrepancies? Can you provide more insights into how the performance of this device compares with existing corrosion testing methods? Additionally, could you elaborate on the implications of these findings for the practical application of your device? - Establishing a theoretical framework for comparison is a good approach, but the manuscript might benefit from a more detailed explanation of this framework, including any assumptions or limitations. - The paper would be better with a stronger conclusion section, succinctly summarizing the findings, following discussions of implications in the broader context of corrosion research and practical applications. Reviewer #2: INTEREST: Dear Editor, I am writing to express my interest in the manuscript titled "Accelerated corrosion of low carbon steel by oscillatory acidic streams generated with a bio-inspired claw device" by Francisco A. Godínez and colleagues. The research discusses a mechanical device inspired by the pistol shrimp's claw, designed to create oscillating flows for studying corrosion rates in carbon steel. It details an innovative method using thin steel samples coated with zinc for electrochemical detection of corrosion, complemented by laser illumination and imaging to locate and count corrosion pits. I believe that the PLOS ONE Journal would be an appropriate venue for this work. However, to meet the exacting standards of this journal, there are key areas in which the manuscript could benefit from further refinement, especially in its presentation and analysis of results. I advocate for a thorough revision, taking into account the detailed feedback provided below. COMMENTS: Please consider the following specific recommendations for revision: a) Why did the authors choose to use an electrolyte composed of a 1:1 volume ratio of 15 wt% HCl acid solution and deionized water for Zn electrodeposition on 1010 steel? Why didn't they use other baths that have much higher current efficiency? b) The corrosion science literature shows that for a material to undergo localized pitting corrosion, it must be in a passive state. And, as I read the manuscript, I became a little confused, as the authors at some points in the manuscript talk about localized corrosion, metastable pits, repassivation, and at others about generalized corrosion. Here are some questions: (i) Is 1010 carbon steel in the passive state in a 2 wt. % HCl solution???; (ii) For such an explanation, it would be extremely important for the authors to present both the potentiodynamic polarization curves and the linear polarization curves (used to determine the Rp values, in the 2 wt. % HCl solution. Given the answer presented by the authors, perhaps it would be important to review the following statement contained in the manuscript “...It has been reported that spikes in the potential signal can be related to the occurrence of metastable pits and rapid repassivation in an electrochemical process [38] [39] [40], indicating a highly unstable electrochemical process on the steel surface when the standard deviation value is high [41]. This, in a way, elucidates why the sample under flow conditions exhibits reduced susceptibility to repassivation and a greater propensity for the pitting process...". c) Before the exposure to the corrosive medium, how were the samples prepared? Were they polished, cleaned, or treated in any way? Surface conditions can significantly influence degradation behaviors. d) When looking at Figure 7 of the manuscript, I get the impression that there are crevices forming at the metal/coating interface of work electrodes. Was there any special care taken to avoid this type of problem when isolating the area to be exposed to the corrosive environment? It would be important for the authors to make some mention of this and say what type of error this could lead to in the measurements. e) When discussing Figure 5, the authors make the following comment: “...In contrast, under static conditions, the potential suffers an abrupt drop to -0.5530 V (point C). This alternating behavior persisted until point D, where the potential drops abruptly below -0.6222 V (point E) due to the appearance and growth of pits that penetrated the 25-micron thickness of the steel, exposing tiny surfaces of Zn. Subsequently, the signal converges towards potentials very close to OCP of the steel/Zn galvanic couple…”. To support this statement, why don't the authors perform potentiodynamic polarization measurements for the Zn coating and then superimpose these measurements on the steel polarization measurements? This way, the authors could empirically prove the value of the Zn/steel galvanic couple. g) In my opinion, the conclusion must be more objective, reflecting the outcome of the work. Please be more concise and critical, highlighting the key findings. Additionally, it would be beneficial to offer suggestions for subsequent research and potential advancements in this domain. Reviewer #3: Dear author, The paper is interesting. In my frank opinion, it deserves to be published after minor revisions: Minor revision of English is necessary. The images are not in good resolution. Viscosity can be changed with pressure, temperature and concentration. In formula 2, wouldn't it be necessary to take these variables into account within viscosity? Why exactly use the green laser? Wouldn't it be more interesting to use a laser in the UV region? The UV laser simulates sunlight. “The images were digitally processed using Python Programming Language to determine”. It would be interesting if you provided, as an attachment, the programming used. “the polarization resistance Rp and the Tafel extrapolation methods were utilized to determine the corrosion rate”. How the externally induced mechanical oscillation affects the charge transfer of the system: In the Tafel extrapolation, the frequency of the electric current through the material is taken into account. Example: formula 6: https://www.mdpi.com/2227-9717/11/3/721 The study you did is very interesting and important. To emphasize the importance of this study, I suggest mentioning, for example in the introduction, other techniques for studying corrosion (currently used in static media, such as Electrochemical Impedance Spectroscopy), fuels such as electrolytes and different material manufacturing routes. Below are examples of articles that illustrate these points. https://journals.sagepub.com/doi/abs/10.1177/00219983211029352 Reviewer #4: Dear authors, below are some comments and suggestions that I consider relevant to the work and doubts that may not have been clarified in the text: 1. It is known that the central objective is not to be the result of the corrosion test but there is a focus on this area as well. It is believed to be interesting to think about applying an equivalent circuit to obtain relevant information regarding corrosion parameters. Below is an indication of reading the articles: GARCIA, A. et al (2009) Electrochemical corrosion response of a low carbon heat treated steel in a NaCl solution. and GARCIA, A. et al. (2010) Electrochemical corrosion behaviour of a Ti-IF steel and a SAE 1020 steel in a 0.5M NaCl solution., where corrosion in steel is discussed. 2. I believe the explanation for the galvanic couple formation after the first pit appearance occurs is vague. Something expected did not happen. 3. The analysis of the formation of pits was never discussed regarding their appearance on the edges of the samples. Is there any influence on the sample preparation or its dimensions? ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: Yes: Carlos Alberto Della Rovere Reviewer #3: Yes: Prof. Dr. Yuri Alexandre Meyer Reviewer #4: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 1 |
|
Accelerated corrosion of low carbon steel by oscillatory acidic streams generated with a bio-inspired claw device PONE-D-23-36475R1 Dear Dr. Montoya, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Wislei Riuper Osório Academic Editor PLOS ONE Additional Editor Comments (optional): Based on the Reviewers’ comments and the rebuttals provided by Author, it is observed that the manuscript was meticulously revised and considerably improved. With this, it deserves its final publication. Reviewers' comments: |
| Formally Accepted |
|
PONE-D-23-36475R1 PLOS ONE Dear Dr. Montoya, I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now being handed over to our production team. At this stage, our production department will prepare your paper for publication. This includes ensuring the following: * All references, tables, and figures are properly cited * All relevant supporting information is included in the manuscript submission, * There are no issues that prevent the paper from being properly typeset If revisions are needed, the production department will contact you directly to resolve them. If no revisions are needed, you will receive an email when the publication date has been set. At this time, we do not offer pre-publication proofs to authors during production of the accepted work. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few weeks to review your paper and let you know the next and final steps. Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. If we can help with anything else, please email us at customercare@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Wislei Riuper Osório Academic Editor PLOS ONE |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .