Peer Review History
Original SubmissionAugust 15, 2023 |
---|
PONE-D-23-26034Increased scalability and sequencing quality of an epigenetic age prediction assayPLOS ONE Dear Dr. Mayne, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. The authors provided and tested an alternative assay for epigenetic ageing particularly for lungfish. My suggestions are as below. 1. PCR master mix is a common practice in molecular biology. It should not be emphasized too much in the Abstract for finding a commercial product suitable for the specific purpose. 2. The Results section is relatively short without enough details. For example, I did not find sample numbers of different experimental groups. Please revise it by adding adequate descriptions. 3. Please make point-by-point responses to the comments of the reviewers. Please submit your revised manuscript by Nov 08 2023 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Xianmin Zhu Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. We note that the grant information you provided in the ‘Funding Information’ and ‘Financial Disclosure’ sections do not match. When you resubmit, please ensure that you provide the correct grant numbers for the awards you received for your study in the ‘Funding Information’ section. 3. Thank you for stating the following financial disclosure: "This study was funded by the CSIRO" Please state what role the funders took in the study. If the funders had no role, please state: "The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript." If this statement is not correct you must amend it as needed. Please include this amended Role of Funder statement in your cover letter; we will change the online submission form on your behalf. 4. We note that you have stated that you will provide repository information for your data at acceptance. Should your manuscript be accepted for publication, we will hold it until you provide the relevant accession numbers or DOIs necessary to access your data. If you wish to make changes to your Data Availability statement, please describe these changes in your cover letter and we will update your Data Availability statement to reflect the information you provide. 5. PLOS ONE now requires that authors provide the original uncropped and unadjusted images underlying all blot or gel results reported in a submission’s figures or Supporting Information files. This policy and the journal’s other requirements for blot/gel reporting and figure preparation are described in detail at https://journals.plos.org/plosone/s/figures#loc-blot-and-gel-reporting-requirements and https://journals.plos.org/plosone/s/figures#loc-preparing-figures-from-image-files. When you submit your revised manuscript, please ensure that your figures adhere fully to these guidelines and provide the original underlying images for all blot or gel data reported in your submission. See the following link for instructions on providing the original image data: https://journals.plos.org/plosone/s/figures#loc-original-images-for-blots-and-gels.
In your cover letter, please note whether your blot/gel image data are in Supporting Information or posted at a public data repository, provide the repository URL if relevant, and provide specific details as to which raw blot/gel images, if any, are not available. Email us at plosone@plos.org if you have any questions. 6. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information. 7. Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The manuscript by Mayne et al. 2023 “Increased scalability and sequencing quality of an epigenetic age prediction assay” compares the effect of two different library preparations on the epigenetic age predictions for the Australian lungfish. The project was well executed and represents an important step in integrating epigenetic clocks in ecological research. I think this manuscript can be improved by including estimates for price and time required for each of these library preparations. I have also outlined specific comments below which will add clarity to the manuscript: Specific comments: Line 23: Given the applications in conservation ecology, consider adding the price/time difference between this method and previous methods. Line 27-28: change text to “age related diseases” Line 35: may be worth citing research demonstrating the utility of using epigenetic clocks designed for one species (i.e. humans) on species with variable evolutionary divergence (i.e. chimpanzees, gorillas[1]) 1. Horvath S. DNA methylation age of human tissues and cell types. Genome Biol. 2013;14: 115. Available: http://genomebiology.com//14/10/R115 Line 70: add number of lungfish samples used. Methods: Instead of grouping methods by the “Bisulfite treatment and Enzymatic deamination” and “Multiplex PCR and DNA sequencing”, I would recommend fully describing the previously established method and the new method in their own sections. It would make it easier to distinguish which text applies to which method. Line 106 & 110-111: what metric did you use to assess sequencing quality? Line 107: add citation for R. Line 114: add “,” after text “As reflected in Figure 1B” Line 122-123: do these statistics refer to one library type or both? If both, it would be useful to report for the individual library types so the reader can compare performance of each method Line 125: what is meant by “bisulfite in this study”? Line 129: what is the cost/time difference between the two methods? Line 149: replace “inevitable” with ‘inevitably” Line 157-158: what are the other possible reasons for this? Are they also method specific? Line 179-180: comparing cost per sample in the methods described here would be useful Discussion: it would be worth addressing the barriers involved with creating the initial epigenetic clock for a given wildlife species (after which these targeted methods can be applied) Figures: Figure 1: In lines 114-115 you state that the enzymatic libraries have greater reads per sample according to their means (t-test). However, figure 1B appears to show higher median reads per sample of the bisulfite libraries (assuming the line in your box plots is the median.) I would clarify which metric you compare statistically and show that metric on the plot. Please also add these details to the figure legend. Also, are the samples which did not pass the threshold for coverage for multiple amplicons included the statistical analysis? I would be interested to know if the mean of reads per sample still differs when excluding the failed samples. Figure 2: Is there a reason some amplicons (i.e. amplicons 5,11,12) have such low coverage in the bisulfite treatment when compared to the others? Also please add details about what is represented by box plot boxes and lines. Reviewer #2: The main claim of the paper is that a new version of epigenetic clock used to predict the age in three fish species is superior to previous versions due to the use of more accurate enzyme-based cytosine methylation sequencing method instead of bisulfite sequencing and of a commercial kit optimized for multiplex PCR instead of home-optimized PCR mixtures. These advantages that seem not to be very significant in laboratory setup may become highly beneficial in wild-life context when both the quality and quantity of DNA samples could be rather low. I view this claim as essentially fair except for few small points. (i) The use of commercial PCR kits is a general practice. Therefore, it hardly deserves a special note in the abstract. (ii) The statement “Unfortunately, bisulfite treatment degrades DNA, which can result in low quality DNA for sequencing and bias in conversion” (Introduction lines 45-46) looks somewhat exaggerated these days. DNA degradation was a serious problem in the early years of bisulfite conversion technology (referenced by a 2007 year paper [20]) but it is mostly overcome in modern BS conversion kits, such as EpiTect Bisulfite Kit from Qiagen or EZ DNA Methylation-Gold™ Kit from Zymo Research. (iii) On lines 55-56 of Introduction, authors state that “In previous studies, the PCR step for amplifying the age-associated loci has involved the handling of multiple PCR additives [18, 19, 25]”. It would be more correctly to write “In our previous studies…” since quite a lot of other people (including myself) use commercial PCR kits, such as NEBNext Q5U Master Mix (included in the NEB NEBNext® Enzymatic Methyl-seq Kit). (iv) Full name of the BS conversion kit used should be indicated on line 77 – EZ-96 DNA Methylation-Gold Kit (Zymo Research Cat. D5008). Otherwise, the Methods section is fine. The methods used are adequate and described in enough detail. (v) In the authors’ hands, EM-seq libraries show better sequencing results compared with BS-seq libraries. As a matter of fact, similar finding was earlier described in a much more detailed and thorough study by Steve Jacobsen lab (reference 22). However, both EM-seq and BS-seq produce results of fair quality. This is especially true for CpG-specific methylation which is the only concern in most studies. Likewise, the read quality in the BS-seq is quite good, though not as good as in EM-seq (Fig.1A), while the age-prediction looks equally good in EM-seq and BS-seq based assays (Fig.3A,B). As concerning the comparison of job intensities between EM-seq and BS-seq protocols (lines 130-133), it should be noted that in fact the BS-seq protocol involves significantly less hands-on time, and it is more streamlined and robust, and probably significantly cheaper, when the commercial BS conversion kits from Qiagen or Zymo Research are used. Taking into account all these aspects, I would say that the choice between EM-seq and BS-seq in most cases is a matter of personal preference. The manuscript is well written and easy to understand. As a matter of fact I have no major concerns both about its content and quality. Few points noted above reflect my personal experience and views and as such are somewhat subjective. I do not demand the authors to agree with them, but it would be fair to discuss these points in more detail. With these minor corrections the manuscript could be accepted for publication in PLOS ONE. Reviewer #3: The manuscript describes a methods to improve the DNA methylation analyis in epigenetic ageing studies. Authors proposed a simple method where bisulfite treatment and a new enzymatic-based method were compared. The manuscript is well written, the introduction provides a good background of the subject matter and experimental apparatus is appropriate for the study. Materials and methods are well described, even if the number of samples analyzed or the number of libraries sequenced are not reported, therefore is difficult to evaluate the robustness of the results. I suggest to indicate this information in the text. Moreover, at rows 132-133 Authors states that “the comparison between the in-house protocol for the multiplex PCR master mix [18] was 7 reagents fewer compared to the commercial master mix used in this study (Supplementary Table 6).” But, as reported in Supplementary Table 6, the number of reagents of the in-house protocol for the multiplex PCR master mix was higher than those of the commercial master mix…11 vs 3. ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: Yes: Vasily Ashapkin Reviewer #3: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
Revision 1 |
Increased scalability and sequencing quality of an epigenetic age prediction assay PONE-D-23-26034R1 Dear Dr. Mayne, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Xianmin Zhu Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: All comments have been addressed Reviewer #2: (No Response) Reviewer #3: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: (No Response) ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: (No Response) ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: (No Response) ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: (No Response) ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The authors have addressed all of the points brought up in my initial review. I think this manuscript will be a nice contribution to the growing interest in epigenetic clocks for ecological research and conservation. Reviewer #2: (No Response) Reviewer #3: (No Response) ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: Yes: Vasily Ashapkin Reviewer #3: No ********** |
Formally Accepted |
PONE-D-23-26034R1 PLOS ONE Dear Dr. Mayne, I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now being handed over to our production team. At this stage, our production department will prepare your paper for publication. This includes ensuring the following: * All references, tables, and figures are properly cited * All relevant supporting information is included in the manuscript submission, * There are no issues that prevent the paper from being properly typeset If revisions are needed, the production department will contact you directly to resolve them. If no revisions are needed, you will receive an email when the publication date has been set. At this time, we do not offer pre-publication proofs to authors during production of the accepted work. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few weeks to review your paper and let you know the next and final steps. Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. If we can help with anything else, please email us at customercare@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Xianmin Zhu Academic Editor PLOS ONE |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .