Peer Review History

Original SubmissionMarch 3, 2023
Decision Letter - Irina U Agoulnik, Editor

PONE-D-23-06181Automation, live-cell imaging, and endpoint cell viability for prostate cancer drug screensPLOS ONE

Dear Dr. Burnstein,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. In addition to providing requested clarifications, please discuss in more detail the advantages of your protocol compared to the high throughput screening techniques with a single treatment option. Perhaps  integrating imaging and ATP levels of a combination treatment would reveal an advantage, as suggested by 2 reviewers.

Please submit your revised manuscript by Jun 08 2023 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Irina U Agoulnik, Ph.D.

Academic Editor

PLOS ONE

Journal requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. We note that you have included the phrase “data not shown” in your manuscript. Unfortunately, this does not meet our data sharing requirements. PLOS does not permit references to inaccessible data. We require that authors provide all relevant data within the paper, Supporting Information files, or in an acceptable, public repository. Please add a citation to support this phrase or upload the data that corresponds with these findings to a stable repository (such as Figshare or Dryad) and provide and URLs, DOIs, or accession numbers that may be used to access these data. Or, if the data are not a core part of the research being presented in your study, we ask that you remove the phrase that refers to these data.

3. Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Does the manuscript report a protocol which is of utility to the research community and adds value to the published literature?

Reviewer #1: Yes

Reviewer #2: Yes

Reviewer #3: Yes

Reviewer #4: Yes

**********

2. Has the protocol been described in sufficient detail?

To answer this question, please click the link to protocols.io in the Materials and Methods section of the manuscript (if a link has been provided) or consult the step-by-step protocol in the Supporting Information files.

The step-by-step protocol should contain sufficient detail for another researcher to be able to reproduce all experiments and analyses.

Reviewer #1: Yes

Reviewer #2: Yes

Reviewer #3: Partly

Reviewer #4: Yes

**********

3. Does the protocol describe a validated method?

The manuscript must demonstrate that the protocol achieves its intended purpose: either by containing appropriate validation data, or referencing at least one original research article in which the protocol was used to generate data.

Reviewer #1: Yes

Reviewer #2: Yes

Reviewer #3: Yes

Reviewer #4: Yes

**********

4. If the manuscript contains new data, have the authors made this data fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: Yes

Reviewer #3: Yes

Reviewer #4: No

**********

5. Is the article presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please highlight any specific errors that need correcting in the box below.

Reviewer #1: Yes

Reviewer #2: Yes

Reviewer #3: Yes

Reviewer #4: Yes

**********

6. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: The authors have established a semi-automated method to screen drugs for the treatment of prostate cancer (PCa). The method employs a combination of microscopic live cell imaging and endpoint proliferation assay. The authors used a BET and CBP/p300 inhibitor and an IGF-1R inhibitor to validate the method.

1. All data presented are from end point assay (cell titer glo), which is just a manual method and has nothing to do with semi automation. It is unclear how the end point assay in this method differs from traditional end point assay. No data interpretation or results from imaging have been provided in detail. May be a correlation between cell titer glo and imaging-based data analysis be helpful to determine the consistency between the methods.

2. AR antagonist screen will be helpful to determine if the method differentiates between AR-positive and -negative cells in terms of growth inhibitory effect.

Reviewer #2: The authors describe an adaptable strategy to optimize assay-specific cell growth conditions and simultaneously assess drug efficacy across multiple cell lines that can be employed across other cancer model systems. While there are numerous publications on drug screening methodologies, there remains room for studies that comprehensive present a detailed and informative approach, especially one that highlights advantages of certain approaches.

There are some issues with the current manuscript that are described below.

It is not clear how “optimal assay conditions” are defined. Is it the linear relationship between cell metabolism and seeding density, as shown and implied in F4? That ignores the dynamic range of the assay to measure growth effects for drug screening. The abstract claims to have demonstrated reliability and reproducibility in the reported screening approach, however, no measurements of reliability or repeatability are presented. These latter quantifiable metrics would be strong measures to define optimal conditions.

The cell numbers plated and growth conditions lead to low confluence at the end of 72hrs. The advantages of this over higher confluence at 72 hrs (the premise from F3A) is unclear.

Was there cell loss with removing media following 24hrs of plating. Experience of many screening labs indicates that removing media from 96 well plates can lead to loss of cells.

“Real-time imaging demonstrated EP-31670 efficacy in prostate cancer as CRPC C4-2B cell proliferation was reduced even in the sub-nanomolar range (Fig 6A).“ The authors must mean sub-micromolar range, which is what the data show.

F6C and F7A-D data should be plotted as dose response curves not a bar graph.

There is no integration of the two (three if you count morphology) endpoints of the approach. Is final cell number (implied from a metabolic assay) or the determined growth rate (from imaged cell confluence) advantageous over the other for detecting “hits” or is using the two provide more sensitivity or selectivity for “hits”. The authors reference a manuscript in preparation of a screen of over 500 compounds, so this manuscript seems to be a companion methods paper. The challenge is that the screen data in that manuscript in preparation may be important to understand any advantages of the approach reported here.

Only single drug effects are reported. In cancer therapy, drug combinations are clearly needed. What advantages do the combined readouts provide for drug combination screens?

Reviewer #3: Line 170 and 171 say that "BPH-1 cells cultured in media supplemented with 2% FBS and seeded at 500 cells/well represented the optimal assay conditions". But in the figure 4, BPH-1 cells are shown to have cell seeding density at 200 cells/well. PLease explain this confusing numbers.

Also, the authors did not clearly explain the use of AUC and AOC in their assays. They need to explain what were these calculations used to evaluate in terms of cell viability or growth or inhibition.

Reviewer #4: While not particularly novel, this is a good protocol paper for drug screens in prostate cell lines - which are notoriously difficult to work with. It has merit for publication, despite the limited amount of screen data presented. These data regarding the example drugs would be nice to include for all cell lines.

**********

7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: No

Reviewer #3: Yes: Manjula Nakka

Reviewer #4: No

**********

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

Revision 1

PONE-D-23-06181

Automation, live-cell imaging, and endpoint cell viability for prostate cancer drug screens

PLOS ONE

We have addressed all reviewer comments in the attached file "Response to Reviewers F"

Attachments
Attachment
Submitted filename: Response to Reviewers F.docx
Decision Letter - Irina U Agoulnik, Editor

Automation, live-cell imaging, and endpoint cell viability for prostate cancer drug screens

PONE-D-23-06181R1

Dear Dr. Burnstein,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Irina U Agoulnik, Ph.D.

Academic Editor

PLOS ONE

Additional Editor Comments (optional):

Reviewers' comments:

Formally Accepted
Acceptance Letter - Irina U Agoulnik, Editor

PONE-D-23-06181R1

Automation, live-cell imaging, and endpoint cell viability for prostate cancer drug screens

Dear Dr. Burnstein:

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department.

If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org.

If we can help with anything else, please email us at plosone@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff

on behalf of

Dr. Irina U Agoulnik

Academic Editor

PLOS ONE

Open letter on the publication of peer review reports

PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.

We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.

Learn more at ASAPbio .