Peer Review History
| Original SubmissionOctober 11, 2022 |
|---|
|
PONE-D-22-26314An Intrauterine Cavity Morcellator: A Novel Approach to High Volume Uterus Morcellation. EX-VIVO StudyPLOS ONE Dear Dr. Daykan, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Dec 16 2022 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Andrea Giannini Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. We note that the grant information you provided in the ‘Funding Information’ and ‘Financial Disclosure’ sections do not match. When you resubmit, please ensure that you provide the correct grant numbers for the awards you received for your study in the ‘Funding Information’ section. 3. PLOS requires an ORCID iD for the corresponding author in Editorial Manager on papers submitted after December 6th, 2016. Please ensure that you have an ORCID iD and that it is validated in Editorial Manager. To do this, go to ‘Update my Information’ (in the upper left-hand corner of the main menu), and click on the Fetch/Validate link next to the ORCID field. This will take you to the ORCID site and allow you to create a new iD or authenticate a pre-existing iD in Editorial Manager. Please see the following video for instructions on linking an ORCID iD to your Editorial Manager account: https://www.youtube.com/watch?v=_xcclfuvtxQ. 6. Please ensure that you refer to Figure 1 in your text as, if accepted, production will need this reference to link the reader to the figure. 7. We note that the original protocol that you have uploaded as a Supporting Information file contains an institutional logo. As this logo is likely copyrighted, we ask that you please remove it from this file and upload an updated version upon resubmission. 8. We note that the original protocol file you uploaded contains a confidentiality notice indicating that the protocol may not be shared publicly or be published. Please note, however, that the PLOS Editorial Policy requires that the original protocol be published alongside your manuscript in the event of acceptance. Please note that should your paper be accepted, all content including the protocol will be published under the Creative Commons Attribution (CC BY) 4.0 license, which means that it will be freely available online, and any third party is permitted to access, download, copy, distribute, and use these materials in any way, even commercially, with proper attribution. Therefore, we ask that you please seek permission from the study sponsor or body imposing the restriction on sharing this document to publish this protocol under CC BY 4.0 if your work is accepted. We kindly ask that you upload a formal statement signed by an institutional representative clarifying whether you will be able to comply with this policy. Additionally, please upload a clean copy of the protocol with the confidentiality notice (and any copyrighted institutional logos or signatures) removed. Additional Editor Comments: Dear authors, the topic of the present article titled “An Intrauterine Cavity Morcellator: A Novel Approach to High Volume Uterus Morcellation. EX-VIVO Study” is very interesting, the paper and the aim falls within the scope of the journal but the article needs major improvements. The introduction, material and method section and tables should be modified and improved. The manuscript should be organized better and English should be improved. I suggest improving the manuscript with the reviewers' comments. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: No Reviewer #4: Yes Reviewer #5: Partly Reviewer #6: Partly ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: N/A Reviewer #4: Yes Reviewer #5: I Don't Know Reviewer #6: No ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes Reviewer #4: Yes Reviewer #5: No Reviewer #6: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes Reviewer #4: Yes Reviewer #5: Yes Reviewer #6: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: This study gives an insight to successful use of intra uterine morcellator. There are a few spelling errors needs to be corrected. The author mentions use of t test and p value in the methodology whereas there has been no such analysis in the results section Reviewer #2: I read with great interest the Manuscript titled “An Intrauterine Cavity Morcellator: A Novel Approach to High Volume Uterus Morcellation. EX-VIVO Study” (PONE-D-22-26314), which falls whithin the aim of Plos One. In my honest opinion, the topic is interesting enough to attract the readers’ attention. Methodology is accurate and conclusions are supported by the data analysis. Nevertheless, authors should clarify some point and improve the discussion citing relevant and novel key articles about the topic. Authors should consider the following recommendations: - Manuscript should be further revised by a native English speaker. - The Authors did not mention the sample size calculation for their study. It is essential to specify this data in order to guarantee an adequate significance of the results obtained by the Authors. - The authors have not adequately highlighted the strengths and limitations of their study. I suggest better specifying these points. - What are the actual clinical implications of this study? it is important to report the results obtained by the authors in the context of clinical practice and to adequately highlight what contribution this study adds to the literature already existing on the topic and to future study perspectives. - Does this manuscript conform the Enhancing the QUAlity and Transparency Of health Research (EQUATOR) network guidelines? It would be mandatory to declare about this element. Reviewer #3: Power morcellators are usually so useful to pick the removed uterus from abdominal cavity. FDA mentioned that under manufacturer’s indication hysteroscopic morcellator does not raise the risk of spreading cancer or fibroid, which is distinct from laparoscopic open morcellation. In the present article, there are several points which should be clarified. #1. Does Heracure morcellator stop automatically or with surgeon’s manipulation? #2. In general, the uterus, which is too large to remove through vaginal orifice is a good indication for morcellation. However, the uterus removed by TAH (case5, 9and 10) tend to suggest poorer response for morcellation and longer time to spend it. Only from the data suggested in this manuscript, it is uncertain whether Heracure morcellator is more useful compared to other kinds of hysteroscopic morcellators. Reviewer #4: Dear Author The topic is current and interesting. The article examines the effectiveness of a morcellator in reducing uterine size intrauterine. As a result, the morcellator used significantly reduced the size of the uterus. Since the study was performed ex-vivo, information about complications could not be obtained. In addition, the number of cases is limited. I think that the study can be published in its current form in order to investigate its use in operations in the future. Yours sincerely Reviewer #5: Reviewer comments on the manuscript titled An Intrauterine Cavity Morcellator: A Novel Approach to High Volume Uterus Morcellation. EX-VIVO Study 1. In the material and method section Page 10 Lines 84 & 85, you mentioned that Patients were followed-up for 6 weeks post – operative. What is the indication for postoperative follow-up while your technique was done ex-vivo on extirpated uteri? Especially that No intervention with your new technique were applied in the patients. And you mentioned that in the lines 87&88 that (No intervention was applied in the patients, as the study only investigated the post-hysterectomy uterus.) 2. In the page 10 line 90 you mentioned that the primary outcome evaluated was the procedure’s safety, how could be determined by this small number of patients (10 patients) and the ex-vivo procedure and choosing only uteri with benign lesions. 3. In the case selection section, page 11, you selected only uteri with benign lesions, you ought to utilize uteri with benign and malignant lesions where the liability for perforation of uterine walls and spreading of malignant cells is more with malignant uterine lesions where the point of your review is to test the safety of the technique in keeping away from perforating the uterine walls and expected spread of malignant cells or injury to nearby vital organs. 4. The protective barrier that was folded over the uterus and was utilized for the separation and avoidance of potential intraperitoneal visceral injury is opened at its upper end, so won't forestall the spillage to the peritoneal cavity assuming perforation of uterine wall happened especially with the utilization of irrigation fluid in controversy to the use of in bag power morcellation that were shown in previous studies. 5. What is the material and length and flexibility of the barrier used and the method of its intraoperative application to surround the whole uterus especially if it is large volume (as 20 weeks size) with interstitial or subserous myomata? 6. In the case number 3& 5&9 &10 the uterine size was large with fibroids what is the type of it, subserous, submucous or interstitial in each case. 7. In case number 1 what is meant by the indication of risk reduction in a uterus weight 365 gram. What is the pathological diagnosis before and after hysterectomy of this case? 8. As the authors mentioned, (in page 19 line 290), In-VIVO trials are required to strength these finding of this limited observation cohort for the safety and efficacy of the procedure, especially that the application of the protective barrier might limit the manipulation of the uterus and visualization of the surrounding bladder or intestine. 9. The chance of uterine perforation won't diminish with this maneuver since morcellation is done indiscriminately without hysteroscopic guide and the role of laparoscopy is just to screen in the event that perforation happened or not and to protect intestine or bladder from injury. 10. If the uterus enlarged by huge subserous myoma uterine perforation definitely occurs and possibility of dissemination of malignant cells is high than enclosed abdominal morcellation. Reviewer #6: The study entitled ‘An Intrauterine Cavity Morcellator: A Novel Approach to High Volume Uterus Morcellation. EX-VIVO Study with the aim to evaluate the safety and efficacy of the intra uterine morcellation device during laparoscopic/vaginal hysterectomy. The manuscript could be improved based on the comments below. Introduction Line 5 rapid recovery[1–3], the cited reference in text to be spaced out from the word. This applies throughout the manuscript. Materials and Methods Line 87 & Line 130, Ex VIVO is to be written as Ex vivo. Line 136 & Line 290, In VIVO is to be replaced with In vivo. Results Table 1 range is to be denoted as min – max values in the table footnote. Percentage figures to be at least 1 decimal point. Sample size is to be indicated in the table. The word Data Mean Range is to be removed and replaced with Variables. Pre-resection uterine size or uterine weight? Size and weight are different in meaning. The short form for gram is g. Table 1 & 2, decimal points for minutes to be added. Was the resection time captured in minutes converted from total seconds? Table 2, columns and data for post-resection uterus size and post-resection uterus circumference to be added before deriving uterus weight and circumference reduction data. Percentage figures to be at least 1 decimal point. Statistical analyses were stated in the manuscript, but there was no statistical analysis output presented. If there were no statistical tests performed, the writeup on statistical analyses is to be omitted, and the reason is to be stated in the method section. Line 215, RR is to be spelled out when first used. Discussion Line 216, proper unit is to be presented for cm2 e.g cm ^2 (superscript 2). Some page numbers which were provided in the TREND Checklist did not tally with the page number in the manuscript. If there is no information provided in the manuscript, the page number should not to be written in the checklist. A write-up could be provided to mention those information were not relevant/applicable in the manuscript. ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: Yes: Shreyashi Aryal Reviewer #2: No Reviewer #3: No Reviewer #4: Yes: Remzi Atilgan Reviewer #5: Yes: Mohamed Ibrahim Mohamed Amer Reviewer #6: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 1 |
|
PONE-D-22-26314R1An Intrauterine Cavity Morcellator: A Novel Approach to High Volume Uterus Morcellation. EX-VIVO StudyPLOS ONE Dear Dr. Daykan, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Feb 10 2023 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Andrea Giannini Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. Additional Editor Comments : Dear Authors, the manuscript it has now been evaluated by our experts and they have recommended that minor changes be made to the submission. Please improving the manuscript with the reviewers' comments. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #3: All comments have been addressed Reviewer #4: All comments have been addressed Reviewer #6: All comments have been addressed Reviewer #7: All comments have been addressed Reviewer #8: (No Response) ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #3: Partly Reviewer #4: Yes Reviewer #6: Partly Reviewer #7: Yes Reviewer #8: Partly ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #3: Yes Reviewer #4: Yes Reviewer #6: Yes Reviewer #7: Yes Reviewer #8: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #3: Yes Reviewer #4: Yes Reviewer #6: Yes Reviewer #7: Yes Reviewer #8: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #3: Yes Reviewer #4: Yes Reviewer #6: Yes Reviewer #7: Yes Reviewer #8: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #3: Thank you for resubmitting your manuscript. As I mentioned previously, the entry number is too small. It seems a kind of preliminary data with supporting Heracure Medical Ltd. It must not reach to the level of this journal. According to your result, the indication to apply Heracure device seems rather small. The enclosed in-bag abdominal morcellation is more useful to remove larger-sized uterus. You need to analyze not only the weight and circumference of the uterus but also the shape and the level of flexio to regulate the appropriate indication. In addition, I am wondering whether the radial panel completely protect the dissemination of the small component of the removing uterus. Compare with the protection you suggested in the revised manuscript, in-bag morcellation seems rather simple and safe. I hope you to submit the renewal manuscript with additional information after further investigation. Reviewer #4: Dear Author, The article has been edited in line with the suggestions. I think the article can be published in its current form. Reviewer #6: (No Response) Reviewer #7: In the discussion, it would be appropriate to include the usual problem of morcellation with electrical instrumentation, versus morcellation with the scalpel. The electric morcellator involves mass being reduced by morcellation of tissue which is delivered to the pathologist as a meat "hamburger". The pathologist, unfortunately, is often unable to distinguish the anatomy to be analyzed and to indicate exactly the parts to be analyzed in anatomical reference of the bowel, given that he has no points of reference (PMID: 36292534). Conversely, manual morcellation with the scalpel allows the organ or mass to be removed and reconstructed with a good approximation using sutures. Therefore I am convinced that this specification can be useful to readers of such a complex and controversial topic. Reviewer #8: I read with great interest the manuscript, which falls within the aim of this Journal. In my honest opinion, the topic is interesting enough to attract the readers’ attention. Nevertheless, the authors should clarify some points and improve the discussion, as suggested below. Authors should consider the following recommendations: - Manuscript should be further revised in order to correct some typos and improve style. - Authors should add further elements to discuss the role and technical differences among Intrauterine Cavity Morcellator (authors may refer to: PMID: 28948169), highlighting that these devices were not affected by the FDA warning about morcellation, which led to the adoption of endogag use as mandatory to avoid the dissemination of misdiagnosed uterine sarcomas (authors may discuss this point referring to: PMID: 35263843; PMID: 36553227). - I recommend to highlight novel pieces of evidence about the minimally invasive management of hysterectomy for large uteri and/or for different indications, as well as the surgical specimen extraction (authors may refer to: PMID: 36498515; PMID: 34730067). ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #3: No Reviewer #4: Yes: Remzi Atılgan Reviewer #6: No Reviewer #7: Yes: ANDREA TINELLI Reviewer #8: No ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 2 |
|
An Intrauterine Cavity Morcellator: A Novel Approach to High Volume Uterus Morcellation. EX-VIVO Study PONE-D-22-26314R2 Dear Dr. Daykan, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Andrea Giannini Academic Editor PLOS ONE Additional Editor Comments (optional): The manuscript has been modified with the comments of the reviewers. It is now ready to be published. Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #6: All comments have been addressed Reviewer #8: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #6: Partly Reviewer #8: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #6: Yes Reviewer #8: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #6: Yes Reviewer #8: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #6: Yes Reviewer #8: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #6: (No Response) Reviewer #8: I carefully evaluated the revised version of this manuscript. Authors have performed the required changes, improving significantly the quality of the paper. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #6: No Reviewer #8: No ********** |
| Formally Accepted |
|
PONE-D-22-26314R2 An Intrauterine Cavity Morcellator: A Novel Approach to High Volume Uterus Morcellation. Ex-vivo Study Dear Dr. Daykan: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Andrea Giannini Academic Editor PLOS ONE |